1.
J Surg Res ; 299: 290-297, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38788465

ABSTRACT

INTRODUCTION: More than 1.2 million pulmonary artery catheters (PACs) are used in cardiac patients per annum within the United States. However, it is contraindicated in traditional 1.5 and 3T magnetic resonance imaging (MRI) scans. We aimed to test preclinical and clinical safety of using this imaging modality given the potential utility of needing it in the clinical setting. METHODS: We conducted two phantom experiments to ensure that the electromagnetic field power deposition associated with bare and jacketed PACs was safe and within the acceptable limit established by the Food and Drug Administration. The primary end points were the safety and feasibility of performing Point-of-Care (POC) MRI without imaging-related adverse events. We performed a preclinical computational electromagnetic simulation and evaluated these findings in nine patients with PACs on veno-arterial extracorporeal membrane oxygenation. RESULTS: The phantom experiments showed that the baseline point specific absorption rate through the head averaged 0.4 W/kg. In both the bare and jacketed catheters, the highest net specific absorption rates were at the neck entry point and tip but were negligible and unlikely to cause any heat-related tissue or catheter damage. In nine patients (median age 66, interquartile range 42-72 y) with veno-arterial extracorporeal membrane oxygenation due to cardiogenic shock and PACs placed for close hemodynamic monitoring, POC MRI was safe and feasible with good diagnostic imaging quality. CONCLUSIONS: Adult ECMO patients with PACs can safely undergo point-of-care low-field (64 mT) brain MRI within a reasonable timeframe in an intensive care unit setting to assess for acute brain injury that might otherwise be missed with conventional head computed tomography.


Subject(s)
Brain , Catheterization, Swan-Ganz , Extracorporeal Membrane Oxygenation , Magnetic Resonance Imaging , Phantoms, Imaging , Point-of-Care Systems , Humans , Male , Middle Aged , Magnetic Resonance Imaging/adverse effects , Magnetic Resonance Imaging/methods , Female , Extracorporeal Membrane Oxygenation/instrumentation , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/methods , Aged , Adult , Brain/diagnostic imaging , Catheterization, Swan-Ganz/instrumentation , Catheterization, Swan-Ganz/adverse effects , Feasibility Studies
2.
ASAIO J ; 70(5): 377-386, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38324706

ABSTRACT

Extracorporeal membrane oxygenation (ECMO) is a temporary lifesaving treatment for critically ill patients with severe respiratory or cardiac failure. Studies demonstrated the feasibility of in-hospital mobilizing during and after ECMO treatment preventing neuromuscular weakness and impaired physical functioning. Despite more compact mobile ECMO devices, implementation of ambulatory ECMO remains labor-intensive, complex, and challenging. It requires a large multidisciplinary team to carry equipment, monitor and physically support the patient, and to provide a back-up wheelchair in case of fatigue. Moreover, there is no adequate solution to ensure the stability of the patient's cannula and circuit management during ambulation. We developed a system contributing to improvement and innovation of current ambulatory ECMO patient programs. Our modular cart-in-cart system carries necessary ECMO equipment, features an extendable walking frame, and contains a folding seat for patient transport. An adjustable shoulder brace with lockable tubing-connectors enables safe fixation of the blood tubing. ECMOve provides safety, support, and accessibility while performing ambulatory ECMO for both patient and caregiver. Prototype evaluation in a simulated intensive care unit showed feasibility of our design, but needs to be evaluated in clinical care.


Subject(s)
Extracorporeal Membrane Oxygenation , Extracorporeal Membrane Oxygenation/instrumentation , Extracorporeal Membrane Oxygenation/methods , Humans , Equipment Design , Critical Illness/therapy , Heart Failure/therapy
3.
Int J Artif Organs ; 47(5): 347-355, 2024 May.
Article in English | MEDLINE | ID: mdl-38742758

ABSTRACT

BACKGROUND: Thrombosis within extracorporeal membrane oxygenation (ECMO) circuits is a common complication that dominates clinical management of patients receiving mechanical circulatory support. Prior studies have identified that over 80% of circuit thrombosis can be attributed to tubing-connector junctions. METHODS: A novel connector was designed that reduces local regions of flow stagnation at the tubing-connector junction to eliminate a primary source of ECMO circuit thrombi. To compare clotting between the novel connectors and the traditional connectors, both in vitro loops and an in vivo caprine model of long-term (48 h) ECMO were used to generate tubing-connector junction clots. RESULTS: In vitro, the traditional connectors uniformly (9/9) formed large thrombi, while novel connectors formed a small thrombus in only one of nine (p < 0.0001). In the long-term goat ECMO circuits, the traditional connectors exhibited more thrombi (p < 0.04), and these thrombi were more likely to protrude into the lumen of the tubing (p < 0.001). CONCLUSION: Both in vitro and in vivo validation experiments successfully recreated circuit thrombosis and demonstrate that the adoption of novel connectors can reduce the burden of circuit thrombosis.


Subject(s)
Equipment Design , Extracorporeal Membrane Oxygenation , Goats , Thrombosis , Extracorporeal Membrane Oxygenation/instrumentation , Animals , Thrombosis/etiology , Thrombosis/prevention & control , Disease Models, Animal , Blood Coagulation
4.
ACS Biomater Sci Eng ; 10(7): 4612-4625, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38904210

ABSTRACT

Premature neonates with underdeveloped lungs experience respiratory issues and need respiratory support, such as mechanical ventilation or extracorporeal membrane oxygenation (ECMO). The "artificial placenta" (AP) is a noninvasive approach that supports their lungs and reduces respiratory distress, using a pumpless oxygenator connected to the systemic circulation, and can address some of the morbidity issues associated with ECMO. Over the past decade, microfluidic blood oxygenators have garnered significant interest for their ability to mimic physiological conditions and incorporate innovative biomimetic designs. Achieving sufficient gas transfer at a low enough pressure drop for a pumpless operation without requiring a large volume of blood to prime such an oxygenator has been the main challenge with microfluidic lung assist devices (LAD). In this study, we improved the gas exchange capacity of our microfluidic-based artificial placenta-type LAD while reducing its priming volume by using a modified fabrication process that can accommodate large-area thin film microfluidic blood oxygenator (MBO) fabrication with a very high gas exchange surface. Additionally, we demonstrate the effectiveness of a LAD assembled by using these scaled-up MBOs. The LAD based on our artificial placenta concept effectively increases oxygen saturation levels by 30% at a flow rate of 40 mL/min and a pressure drop of 23 mmHg in room air, which is sufficient to support partial oxygenation for 1 kg preterm neonates in respiratory distress. When the gas ambient environment was changed to pure oxygen at atmospheric pressure, the LAD would be able to support premature neonates weighing up to 2 kg. Furthermore, our experiments reveal that the LAD can handle high blood flow rates of up to 150 mL/min and increase oxygen saturation levels by ∼20%, which is equal to an oxygen transfer of 7.48 mL/min in an enriched oxygen environment and among the highest for microfluidic AP type devices. Such performance makes this LAD suitable for providing essential support to 1-2 kg neonates in respiratory distress.


Subject(s)
Placenta , Female , Pregnancy , Humans , Artificial Organs , Infant, Newborn , Lab-On-A-Chip Devices , Lung , Extracorporeal Membrane Oxygenation/instrumentation , Extracorporeal Membrane Oxygenation/methods , Pulmonary Gas Exchange/physiology
5.
Comput Methods Programs Biomed ; 250: 108186, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38692252

ABSTRACT

BACKGROUND AND OBJECTIVES: Venovenous Extracorporeal Membrane Oxygenation (VV ECMO) provides respiratory support to patients with severe lung disease failing conventional medical therapy. An essential component of the ECMO circuit are the cannulas, which drain and return blood into the body. Despite being anchored to the patient to prevent accidental removal, minor cannula movements are common during ECMO. The clinical and haemodynamic consequences of these small movements are currently unclear. This study investigated the risk of thrombosis and recirculation caused by small movements of a dual lumen cannula (DLC) in an adult using computational fluid dynamics. METHODS: The 3D model of an AVALON Elite DLC (27 Fr) and a patient-specific vena cava and right atrium were generated for an adult patient on ECMO. The baseline cannula position was generated where the return jet enters the tricuspid valve. Alternative cannula positions were obtained by shifting the cannula 5 and 15 mm towards inferior (IVC) and superior (SVC) vena cava, respectively. ECMO settings of 4 L/min blood flow and pulsatile flow at SVC and IVC were applied. Recirculation was defined as a scalar value indicating the infused oxygenated blood inside the drainage lumen, while thrombosis risk was evaluated by shear stress, stagnation volume, washout, and turbulent kinetic energy. RESULTS: Recirculation for all models was less than 3.1 %. DLC movements between -5 to 15 mm increased shear stress and turbulence kinetic energy up to 24.7 % and 11.8 %, respectively, compared to the baseline cannula position leading to a higher predicted thrombosis risk. All models obtained a complete washout after nine seconds except for when the cannula migrated 15 mm into the SVC, indicating persisting stasis and circulating zones. CONCLUSION: In conclusion, small DLC movements were not associated with an increased risk of recirculation. However, they may increase the risk of thrombosis due to increased shear rate, turbulence, and slower washout of blood. Developing effective cannula securement devices may reduce this risk.


Subject(s)
Cannula , Extracorporeal Membrane Oxygenation , Hydrodynamics , Extracorporeal Membrane Oxygenation/instrumentation , Humans , Thrombosis/etiology , Thrombosis/prevention & control , Computer Simulation , Adult , Hemodynamics , Models, Cardiovascular
6.
Sci Rep ; 14(1): 10438, 2024 05 07.
Article in English | MEDLINE | ID: mdl-38714704

ABSTRACT

Thrombus formation in extracorporeal membrane oxygenation (ECMO) remains a major concern as it can lead to fatal outcomes. To the best of our knowledge, there is no standard non-invasive method for quantitatively measuring thrombi. This study's purpose was to verify thrombus detection in an ECMO circuit using novel, non-invasive ultrasonic sensors in real-time, utilizing the fact that the ultrasonic velocity in a thrombus is known to be higher than that in the blood. Ultrasonic sensors with a customized chamber, an ultrasonic pulse-receiver, and a digital storage oscilloscope (DSO) were used to set up the measuring unit. The customized chamber was connected to an ECMO circuit primed with porcine blood. Thrombi formed from static porcine blood were placed in the circuit and ultrasonic signals were extracted from the oscilloscope at various ECMO flow rates of 1-4 L/min. The ultrasonic signal changes were successfully detected at each flow rate on the DSO. The ultrasonic pulse signal shifted leftward when a thrombus passed between the two ultrasonic sensors and was easily detected on the DSO screen. This novel real-time non-invasive thrombus detection method may enable the early detection of floating thrombi in the ECMO system and early management of ECMO thrombi.


Subject(s)
Extracorporeal Membrane Oxygenation , Thrombosis , Extracorporeal Membrane Oxygenation/methods , Extracorporeal Membrane Oxygenation/instrumentation , Thrombosis/diagnostic imaging , Thrombosis/diagnosis , Animals , Swine , Ultrasonics , Ultrasonography/methods
7.
ASAIO J ; 70(6): 535-544, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38165978

ABSTRACT

Microfluidic membrane oxygenators are designed to mimic branching vasculature of the native lung during extracorporeal lung support. To date, scaling of such devices to achieve clinically relevant blood flow and lung support has been a limitation. We evaluated a novel multilayer microfluidic blood oxygenator (BLOx) capable of supporting 750-800 ml/min blood flow versus a standard hollow fiber membrane oxygenator (HFMO) in vivo during veno-venous extracorporeal life support for 24 hours in anesthetized, mechanically ventilated uninjured swine (n = 3/group). The objective was to assess feasibility, safety, and biocompatibility. Circuits remained patent and operated with stable pressures throughout 24 hours. No group differences in vital signs or evidence of end-organ damage occurred. No change in plasma free hemoglobin and von Willebrand factor multimer size distribution were observed. Platelet count decreased in BLOx at 6 hours (37% dec, P = 0.03), but not in HFMO; however, thrombin generation potential was elevated in HFMO (596 ± 81 nM·min) versus BLOx (323 ± 39 nM·min) at 24 hours ( P = 0.04). Other coagulation and inflammatory mediator results were unremarkable. BLOx required higher mechanical ventilator settings and showed lower gas transfer efficiency versus HFMO, but the stable device performance indicates that this technology is ready for further performance scaling and testing in lung injury models and during longer use conditions.


Subject(s)
Feasibility Studies , Oxygenators, Membrane , Animals , Swine , Extracorporeal Membrane Oxygenation/instrumentation , Extracorporeal Membrane Oxygenation/methods , Extracorporeal Membrane Oxygenation/adverse effects , Intensive Care Units , Microfluidics/methods , Microfluidics/instrumentation
8.
J Extra Corpor Technol ; 56(2): 65-70, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38888549

ABSTRACT

Pressure monitoring on pediatric Extracorporeal Membrane Oxygenation (ECMO) circuits is used to aid in the evaluation of patient hemodynamics and circuit health. Extracorporeal Life Support Organization (ELSO) recommends monitoring pressures on the venous line, pre-, and post-oxygenator. In order to keep pressure ports patent, crystalloid can be used as a flush. The fluid transfused to the patient through these lines can be challenging to quantify accurately due to variance in clinician practice. Currently, there is no published data or practice suggestions on this topic. In Vitro experiments using Edwards True Wave transducers and pressure bags were constructed, allowing for common negative and positive pressures to be simulated. Passive volume infused through the transducer as well as intermittent active flushing by pulling the snap tab were measured and the volumes were recorded. When the pressure transducer and associated tubing are kept patent by using a pressurized IV bag, per the instructions for use, the daily volume transfused was found to be 319.6 mL or close to a typical neonate's total blood volume. Rather than using passive or active flushing, the use of automated syringe pumps can reduce the transfused volume to 24 mL per day. Further study is recommended to develop and publish best practices.


Subject(s)
Extracorporeal Membrane Oxygenation , Extracorporeal Membrane Oxygenation/instrumentation , Extracorporeal Membrane Oxygenation/methods , Humans , Fluid Therapy/instrumentation , Fluid Therapy/methods , Child , Equipment Design , Infant, Newborn
9.
ASAIO J ; 70(8): 698-703, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38417432

ABSTRACT

Nitric oxide (NO) can be safely delivered through the sweep gas to the oxygenator of an extracorporeal membrane oxygenation (ECMO) circuit. It has theoretical benefits such as preventing platelet adhesion to surfaces, mitigating inflammatory response and protection against ischemia-reperfusion injury. In this uncontrolled before-after study of children on ECMO, the outcomes of those who received NO were compared with those who did not. Among 393 ECMO runs (from 337 patients), 192 of 393 (49%) received NO and 201 of 393 (51%) did not. The use of NO was associated with a 37% reduction in circuit change (adjusted risk ratio [aRR]: 0.63, 95% confidence interval [CI]: 0.42-0.93). The aRR (95% CI) for risk of neurologic injury was 0.72 (0.47-1.11). We observed potential heterogeneity of treatment effect for the risk of neurologic injury in children who had cardiac surgery: the risk with NO was lower in those who had cardiac surgery (aRR: 0.50, 95% CI: 0.26-0.96). There was no difference in survival between the study groups. In children managed with NO delivered through the ECMO circuit, we report a reduction in observed rate of circuit change and lower risk of neurologic injury in children who underwent cardiac surgery. Nitric oxide therapy on ECMO warrants prospective evaluation in children.


Subject(s)
Extracorporeal Membrane Oxygenation , Nitric Oxide , Humans , Extracorporeal Membrane Oxygenation/methods , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/instrumentation , Nitric Oxide/administration & dosage , Infant , Male , Female , Child, Preschool , Cohort Studies , Child , Infant, Newborn , Treatment Outcome , Oxygenators
10.
Adv Sci (Weinh) ; 11(30): e2401524, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38757670

ABSTRACT

Use of extracorporeal membrane oxygenation (ECMO) for cardiorespiratory failure remains complicated by blood clot formation (thrombosis), triggered by biomaterial surfaces and flow conditions. Thrombosis may result in ECMO circuit changes, cause red blood cell hemolysis, and thromboembolic events. Medical device thrombosis is potentiated by the interplay between biomaterial properties, hemodynamic flow conditions and patient pathology, however, the contribution and importance of these factors are poorly understood because many in vitro models lack the capability to customize material and flow conditions to investigate thrombosis under clinically relevant medical device conditions. Therefore, an ECMO thrombosis-on-a-chip model is developed that enables highly customizable biomaterial and flow combinations to evaluate ECMO thrombosis in real-time with low blood volume. It is observed that low flow rates, decelerating conditions, and flow stasis significantly increased platelet adhesion, correlating with clinical thrombus formation. For the first time, it is found that tubing material, polyvinyl chloride, caused increased platelet P-selectin activation compared to connector material, polycarbonate. This ECMO thrombosis-on-a-chip model can be used to guide ECMO operation, inform medical device design, investigate embolism, occlusion and platelet activation mechanisms, and develop anti-thrombotic biomaterials to ultimately reduce medical device thrombosis, anti-thrombotic drug use and therefore bleeding complications, leading to safer blood-contacting medical devices.


Subject(s)
Extracorporeal Membrane Oxygenation , Lab-On-A-Chip Devices , Platelet Activation , Platelet Adhesiveness , Thrombosis , Extracorporeal Membrane Oxygenation/methods , Extracorporeal Membrane Oxygenation/instrumentation , Thrombosis/etiology , Humans , Platelet Activation/physiology , Blood Platelets/metabolism
11.
ASAIO J ; 70(7): e89-e91, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38277338

ABSTRACT

Left ventricular (LV) unloading has been shown to improve survival for patients requiring veno-arterial extracorporeal membrane oxygenation (VA ECMO) support for cardiogenic shock. A mortality benefit has been shown for ECMO and concomitant placement of a transcatheter unloading LV pump such as an Impella device (colloquially referred to as ECPELLA or ECMELLA) for patients resuscitated with VA ECMO after a short period of cardiac arrest. Despite the described benefit of LV unloading with VA ECMO for cardiopulmonary resuscitation, it remains unclear as to what criteria should be used and what other diagnostic and therapeutic adjuncts may be useful. We describe here the successful utilization of concomitant VA ECMO and Impella in a 43 year old male with acute heart failure and cardiac arrest. Distinguishing itself from the currently reported methods, our methodology incorporates transesophageal echocardiography (TEE) in the emergency department for rapid decision-making in addition to an automatic chest compression device, the Lund University Cardiac Assist System (LUCAS) device (Stryker, Portage, MI) as a bridge to LV unloading in a hybrid operating suite.


Subject(s)
Extracorporeal Membrane Oxygenation , Heart-Assist Devices , Humans , Male , Extracorporeal Membrane Oxygenation/methods , Extracorporeal Membrane Oxygenation/instrumentation , Adult , Shock, Cardiogenic/therapy , Heart Ventricles/physiopathology , Heart Failure/therapy , Heart Failure/physiopathology , Echocardiography, Transesophageal/methods , Heart Arrest/therapy , Cardiopulmonary Resuscitation/methods , Cardiopulmonary Resuscitation/instrumentation
12.
Medicine (Baltimore) ; 103(30): e39094, 2024 Jul 26.
Article in English | MEDLINE | ID: mdl-39058830

ABSTRACT

RATIONALE: Extracorporeal membrane oxygenation (ECMO) is the last trump card for severe respiratory failure. The main complications of ECMO are bleeding and thrombosis, both of which can be life-threatening. Large blood clots can cause central airway obstruction (CAO) during ECMO, and CAO should be removed as soon as possible because of asphyxiation. However, there is no comprehensive reports on its frequency and management. The purpose of this study is to share therapeutic experiences for rare and serious conditions and provide valuable insights. PATIENT CONCERNS: We report 3 patients placed on ECMO for severe respiratory failure. DIAGNOSIS: CAO due to large blood clots occurred during ECMO in all 3 patients. INTERVENTIONS: Large blood clots were removed using flexible bronchoscopy, grasping forceps, and net retrieval devices in all 3 patients. OUTCOMES: In all 3 patients, large blood clots were removed multiple times during ECMO. The patients' respiratory conditions improved and they were eventually weaned off the ECMO. LESSONS: CAO due to large blood clots during ECMO is rare. The frequency of CAO requiring bronchoscopic removal was estimated to be approximately 1,5%. When this occurs, clots should be removed as soon as possible. Net retrieval devices are useful tools for the collection of large blood clots.


Subject(s)
Airway Obstruction , Extracorporeal Membrane Oxygenation , Thrombosis , Humans , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/methods , Extracorporeal Membrane Oxygenation/instrumentation , Airway Obstruction/etiology , Airway Obstruction/therapy , Male , Thrombosis/etiology , Female , Bronchoscopy/methods , Bronchoscopy/adverse effects , Respiratory Insufficiency/therapy , Respiratory Insufficiency/etiology , Middle Aged , Adult
13.
Cardiovasc Revasc Med ; 62: 60-65, 2024 May.
Article in English | MEDLINE | ID: mdl-38184452

ABSTRACT

PURPOSE: Mechanical circulatory support (MCS) using a venoarterial extracorporeal membrane oxygenation (VA-ECMO) device or a catheter-type heart pump (Impella) is critical for the rescue of patients with severe cardiogenic shock. However, these MCS devices require large-bore cannula access (14-Fr and larger) at the femoral artery or vein, which often requires surgical decannulation. METHODS: In this retrospective study, we evaluated post-closure method using a percutaneous suture-mediated vascular closure system, Perclose ProGlide/ProStyle (Abbott Vascular, Lake Bluff, IL, Perclose), as an alternative procedure for MCS decannulation. Closure of 83 Impella access sites and 68 VA-ECMO access sites performed using Perclose or surgical method between January 2018 and March 2023 were evaluated. RESULTS: MCS decannulation using Perclose was successfully completed in all access sites without surgical hemostasis. The procedure time of ProGlide was shorter than surgical decannulation for both Impella and VA-ECMO (13 min vs. 50 min; p < 0.001, 21 min vs. 65 min; p < 0.001, respectively). There were no significant differences in the 30-day survival rate and major adverse events by decannulation including arterial dissection requiring endovascular treatment, hemorrhage requiring a large amount of red blood cell transfusion, and access site infection. CONCLUSION: Our results suggest that the post-closure technique using the percutaneous suture-mediated closure system appears to be a safe and effective method for large-bore MCS decannulation.


Subject(s)
Catheterization, Peripheral , Extracorporeal Membrane Oxygenation , Heart-Assist Devices , Hemostatic Techniques , Punctures , Vascular Closure Devices , Humans , Retrospective Studies , Male , Female , Treatment Outcome , Middle Aged , Aged , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/instrumentation , Time Factors , Hemostatic Techniques/instrumentation , Hemostatic Techniques/adverse effects , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Device Removal/adverse effects , Suture Techniques/instrumentation , Suture Techniques/adverse effects , Femoral Artery , Shock, Cardiogenic/therapy , Shock, Cardiogenic/mortality , Shock, Cardiogenic/physiopathology , Shock, Cardiogenic/diagnosis , Risk Factors , Hemorrhage/etiology , Hemorrhage/prevention & control
14.
ASAIO J ; 70(7): 565-569, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38949771

ABSTRACT

National trends show rapid increases in the use of mechanical circulatory support devices (MCSD) over the last 20 years. While current literature has not proven a mortality benefit in cardiogenic shock as a complication of acute myocardial infarction (AMI-CS) with percutaneous MCSD, these devices are vital to maximizing cardiopulmonary parameters for definitive therapy. To minimize complications, many different techniques have been described including a novel off-pump direct apical cannulation for venoarterial-extracorporeal membrane oxygenation (VA-ECMO). This technique allows early ambulation and avoids peripheral artery access complications but has only been described in small case series. Our case series represents the largest summary of patients (50) using this technique and contains the only comparison data to date. Fifty-four percentage of our patients were Society for Cardiovascular Angiography and Interventions (SCAI) stage D and 22% were arrested before cannulation. We achieved flows on average >5 L/min and most patients required biventricular drainage (86%) and an oxygenator (92%). Thirty day survival was 56% and most survivors were bridged to heart transplant (30%). Our most common complication was bleeding (16%). This technique showed significant improvement in ejection fraction (EF), cardiac output/index (CO/CI), and pulmonary artery pressures. This case series demonstrates the safety and efficacy of this novel technique for central cannulation in cardiogenic shock at large scale within a single institution.


Subject(s)
Cannula , Extracorporeal Membrane Oxygenation , Shock, Cardiogenic , Humans , Extracorporeal Membrane Oxygenation/methods , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/instrumentation , Middle Aged , Male , Female , Shock, Cardiogenic/therapy , Shock, Cardiogenic/surgery , Aged , Thoracotomy/methods , Thoracotomy/adverse effects , Catheterization/methods , Catheterization/adverse effects , Catheterization/instrumentation , Adult , Myocardial Infarction , Heart-Assist Devices/adverse effects
15.
Rev. cuba. pediatr ; 952023. tab
Article in Spanish | LILACS, CUMED | ID: biblio-1441833

ABSTRACT

Introducción: Las cardiopatías congénitas son causa frecuente de insuficiencia cardíaca mientras las cardiopatías adquiridas resultan menos frecuentes. La expresión clínica difiere en gran manera de la población adulta y representa la emergencia cardiovascular más frecuente en pediatría. El diagnóstico es completamente clínico, y el tratamiento está encaminado a corregir la causa que la origina. Objetivo: Actualizar conceptos, fisiopatología, manifestaciones clínicas, y tratamiento de la insuficiencia cardíaca en pediatría. Métodos: Se revisaron las bases de datos Medline, PubMed, SciELO y plataforma Springerlink, disponibles desde Infomed; desde el año 2000 hasta 2020, en idioma español e inglés. Análisis y síntesis de la información: La insuficiencia cardíaca es un síndrome clínico resultado de disfunción ventricular, sobrecarga de presión o volumen, independiente o en combinación, que conlleva a signos y síntomas característicos. La identificación de su causa, el diagnóstico precoz y el tratamiento oportuno mejoraran el pronóstico de los pacientes aquejados. Conclusiones: La insuficiencia cardíaca en edad pediátrica representa una compleja afección de causas multifactoriales. El diagnóstico puede hacerse con el método clínico, complementándose con los diferentes exámenes. El tratamiento médico farmacológico o no, se encamina a tratar la causa, además de nuevas terapias en desarrollo prometedoras en el futuro(AU)


Introduction: Congenital heart disease is a frequent cause of heart failure while acquired heart disease is less frequent. The clinical expression differs greatly from the adult population and represents the most frequent cardiovascular emergency in pediatrics. Diagnosis is completely clinical and treatment is aimed at correcting the cause. Objective: To update concepts, pathophysiology, clinical manifestations and treatment of heart failure in pediatrics. Methods: The databases Medline, PubMed, SciELO and Springerlink platform, available from Infomed, were reviewed from 2000 to 2020, in Spanish and English. Analysis and synthesis of the information: Heart failure is a clinical syndrome resulting from ventricular dysfunction, pressure or volume overload, independently or in combination, leading to characteristic signs and symptoms. Identification of its cause, early diagnosis and timely treatment improve the prognosis of afflicted patients. Conclusions: Heart failure in pediatric age represented a complex condition with multifactorial causes. The diagnosis can be made with the clinical method, complemented with different examinations. Pharmacological or non-pharmacological medical treatment is aimed at treating the cause, in addition to promising new therapies under development in the future(AU)


Subject(s)
Humans , Infant , Child, Preschool , Heart Defects, Congenital/etiology , Heart Failure/etiology , Heart Failure/physiopathology , Heart Failure/therapy , Heart Failure/epidemiology , Serial Publications , Extracorporeal Membrane Oxygenation/instrumentation , Clinical Laboratory Techniques/methods , Heart Auscultation , Heart Failure/classification
16.
Rev. bras. anestesiol ; 70(1): 55-58, Jan.-Feb. 2020. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1137135

ABSTRACT

Abstract Background: Veno-venous extracorporeal membrane oxygenation is an established therapy for patients with refractory acute respiratory distress syndrome (ARDS). One complication related to the use of veno-venous extracorporeal membrane oxygenation is thrombosis despite proper anticoagulation. We report the diagnosis and management of a clot-obstruction in a single site cannula placed through the internal jugular vein, guided by transesophageal echocardiography. Case report: A 39 year-old male developed acute respiratory distress syndrome and hemodynamic instability after an episode of pulmonary aspiration in the ICU. Eight hours after placement of a single site veno-venous extracorporeal membrane oxygenation, suddenly the perfusionist noticed a reduction in flow. TEE showed a thrombus-like mass obstructing the inflow port in SVC and inflow at IVC was intact. After unsuccessful attempts to reposition the cannula, the team decided to insert additional femoral inflow cannula through the IVC. The single site catheter was then pulled out until its tip was positioned in the right atrium and all three ports of the catheter were switched to the infusion ports. After this, flows and oxygenation improved significantly. Unfortunately, despite all of the efforts, the patient died 2 days later. Discussion: The diagnosis of veno-venous extracorporeal membrane oxygenation cannula obstruction is based on reduced inflow rates, hemodynamic instability and poor oxygenation of blood. TEE allows evaluation of the flows inside the cannula and in this case, an obstruction was found. The management presented points to the fact that in a situation of catheter obstruction caused by a clot, there is a feasible alternative to assure minimal interruption of the hemodynamic support offered by the veno-venous extracorporeal membrane oxygenation.


Resumo Justificativa: A oxigenação por membrana extracorpórea veno-venosa é terapia estabelecida para pacientes com a síndrome do desconforto respiratório agudo. Uma complicação relacionada ao uso da oxigenação por membrana extracorpórea veno-venosa é trombose apesar de anti-coagulação adequada. Relatamos o diagnóstico e conduta em obstrução por coágulo em cânula de acesso único inserida pela veia jugular interna, guiada por ecocardiografia transesofageana. Relato de caso: Paciente do sexo masculino de 39 anos desenvolveu síndrome do desconforto respiratório agudo e instabilidade hemodinâmica após episódio de aspiração pulmonar na UTI. Oito horas após a instalação de oxigenação por membrana extracorpórea veno-venosa de acesso único, o perfusionista notou repentina redução no fluxo. A ETE revelou massa semelhante a um trombo obstruindo o portal de fluxo de entrada na VCS e o fluxo de saída na VCI estava intacto. Após tentativas sem sucesso para reposicionar a cânula, a equipe decidiu inserir cânula de entrada de fluxo adicional pela VCI. O catéter de acesso único foi, então, puxado até que sua ponta se posicionasse no átrio direito e todos os três portais do catéter fossem transferidos para os portais de infusão. A seguir, os fluxos e oxigenação melhoraram significativamente. Infelizmente, apesar dos esforços, o paciente foi a óbito 2 dias depois. Discussão: O diagnóstico de obstrução de cânula da oxigenação por membrana extracorpórea veno-venosa se baseia em velocidades reduzidas de entrada de fluxo, instabilidade hemodinâmica e oxigenação pobre do sangue. A ETE permite a avaliação dos fluxos dentro da cânula, e nesse caso foi encontrada obstrução. A técnica apresentada aponta para o fato de que em situação de obstrução de catéter causada por coágulo, existe alternativa factível para garantir interrrupção mínima do suporte hemodinâmico oferecido pela oxigenação por membrana extracorpórea veno-venosa.


Subject(s)
Humans , Male , Adult , Respiratory Distress Syndrome, Newborn/therapy , Thrombosis/etiology , Extracorporeal Membrane Oxygenation/instrumentation , Cannula/adverse effects , Thrombosis/therapy , Thrombosis/diagnostic imaging , Venae Cavae , Echocardiography, Transesophageal
17.
Rev. bras. ter. intensiva ; 31(3): 410-424, jul.-set. 2019. tab, graf
Article in Portuguese | LILACS | ID: biblio-1042589

ABSTRACT

RESUMO A oxigenação por membrana extracorpórea é uma modalidade de suporte de vida extracorpóreo que possibilita suporte temporário à falência da função pulmonar e/ou cardíaca, refratária ao tratamento clínico convencional. Desde as primeiras descrições da oxigenação por membrana extracorpórea, melhorias significativas ocorreram no dispositivo, no manejo do paciente e, consequentemente, nos desfechos dos pacientes em oxigenação por membrana extracorpórea. Diversos estudos importantes sobre a utilização de oxigenação por membrana extracorpórea em pacientes com síndrome do desconforto respiratório agudo refratária ao suporte clínico convencional, em parada cardíaca intra-hospitalar e choque cardiogênico refratário foram publicados nos últimos anos. Dessa forma, o objetivo desta revisão é apresentar conceitos teóricos e práticos sobre a utilização da oxigenação por membrana extracorpórea em situações de falência pulmonar e/ou cardíaca refratária ao manejo clínico convencional em pacientes críticos.


ABSTRACT Extracorporeal membrane oxygenation is a modality of extracorporeal life support that allows for temporary support in pulmonary and/or cardiac failure refractory to conventional therapy. Since the first descriptions of extracorporeal membrane oxygenation, significant improvements have occurred in the device and the management of patients and, consequently, in the outcomes of critically ill patients during extracorporeal membrane oxygenation. Many important studies about the use of extracorporeal membrane oxygenation in patients with acute respiratory distress syndrome refractory to conventional clinical support, under in-hospital cardiac arrest and with cardiogenic refractory shock have been published in recent years. The objective of this literature review is to present the theoretical and practical aspects of extracorporeal membrane oxygenation support for respiratory and/or cardiac functions in critically ill patients.


Subject(s)
Humans , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/instrumentation , Critical Illness/therapy , Equipment Design
18.
Rev. bras. ter. intensiva ; 28(1): 78-82, jan.-mar. 2016. tab, graf
Article in Portuguese | LILACS | ID: lil-780005

ABSTRACT

RESUMO A oxigenação por membrana extracorpórea é utilizada em casos de hipoxemia refratária em diversas condições clínicas. Pacientes vítimas de traumatismo torácico geralmente desenvolvem síndrome da angústia respiratória aguda. Em razão do elevado risco de sangramentos, as complicações trombóticas que se apresentam neste contexto são particularmente difíceis de tratar e, geralmente, demandam a inserção de um filtro na veia cava inferior, com a finalidade de prevenir a migração de êmbolos oriundos das veias distais para a circulação pulmonar. Neste artigo, apresentamos o caso de um paciente com traumatismo torácico, que apresentou grave síndrome de angústia respiratória aguda, com necessidade de utilizar oxigenação por membrana extracorpórea aplicada por meio da introdução de uma cânula com duplo-lúmen na veia jugular interna direita. Este procedimento foi realizado tendo em vista a prévia inserção de um filtro na veia cava inferior, por conta da ocorrência de trombose venosa profunda em ambas as panturrilhas.


ABSTRACT Extracorporeal membrane oxygenation is used in refractory hypoxemia in many clinical settings. Thoracic trauma patients usually develop acute respiratory distress syndrome. Due to high risk of bleeding, thrombotic complications present in this context are particularly difficult to manage and usually require insertion of an inferior vena cava filter to prevent embolism from the distal veins to the pulmonary circulation. Here, we present a case of a thoracic trauma patient with severe acute respiratory distress syndrome requiring venovenous extracorporeal membrane oxygenation via a right internal jugular double lumen cannula due to a previously inserted inferior vena cava filter caused by distal bilateral calf muscle vein deep vein thrombosis.


Subject(s)
Humans , Male , Aged , Respiratory Distress Syndrome/therapy , Extracorporeal Membrane Oxygenation/methods , Vena Cava Filters , Pulmonary Embolism/prevention & control , Extracorporeal Membrane Oxygenation/instrumentation , Cannula
19.
Rev. bras. cir. cardiovasc ; 30(6): 657-659, Nov.-Dec. 2015. tab
Article in English | LILACS | ID: lil-774549

ABSTRACT

ABSTRACT As Marcelo Giugale published in the Financial Times, Latin America, on the whole, has not excelled at innovation - doing the same things in a new and better way or at doing new things. It has been slow to acquire, adopt and adapt technologies by this time available in other places[1]. Although extracorporeal membrane oxygenation (ECMO) is not a new technology, its use in Latin America is not widespread as needed. Furthermore, we still have a number centers doing ECMO, not reporting their cases, lacking a structured training program and not registered with the extracorporeal life support organization (ELSO). With this scenario, and accepting that ECMO is the first step in any circulatory support program, it is difficult to anticipate the incorporation of new and more complex devices as the technologically advanced world is currently doing. However, the good news is that with the support of experts from USA, Europe and Canada the results in Latin America ELSO'S centers are improving by following its guidelines for training, and using a standard educational process. There is no doubt that we can learn a great deal from the high velocity organizations - the rabbits - whom everyone chases but never catches, that manage to stay ahead because of their endurance, responsiveness, and their velocity in self-correction[2].


Subject(s)
Humans , Extracorporeal Membrane Oxygenation/instrumentation , Life Support Care/trends , Cardiovascular Surgical Procedures/instrumentation , Extracorporeal Membrane Oxygenation , Latin America , Life Support Care/instrumentation
20.
Rev. bras. cir. cardiovasc ; 30(4): 409-416, July-Aug. 2015. tab, graf
Article in English | LILACS | ID: lil-763159

ABSTRACT

AbstractIntroduction:Post-cardiotomy myocardial dysfunction requiring mechanical circulatory support occurs in about 0.5% of cases. In our environment, the use of extracorporeal membrane oxygenation has been increasing in recent years.Objective:To evaluate the impact of investment in professional training and improvement of equipment in the rate of weaning from extracorporeal membrane oxygenation and survival.Methods:A retrospective study. Fifty-six pediatric and/or congenital heart patients underwent post-cardiotomy extracorporeal membrane oxygenation at our institution between November 1999 and July 2014. We divided this period into two phases: phase I, 36 cases (before the structuring of the extracorporeal membrane oxygenation program) and phase II, 20 cases (after the extracorporeal membrane oxygenation program implementation) with investment in training and equipment). Were considered as primary outcomes: extracorporeal membrane oxygenation weaning and survival to hospital discharge. The results in both phases were compared using Chi-square test. To identify the impact of the different variables we used binary logistic regression analysis.Results:Groups were comparable. In phase I, 9 patients (25%) were weaned from extracorporeal membrane oxygenation, but only 2 (5.5%) were discharged. In phase II, extracorporeal membrane oxygenation was used in 20 patients, weaning was possible in 17 (85%), with 9 (45%) hospital discharges (P<0.01). When the impact of several variables on discharge and weaning of extracorporeal membrane oxygenation was analyzed, we observe that phase II was an independent predictor of better results (P<0.001) and need for left cavities drainage was associated with worse survival (P=0.045).Conclusion:The investment in professional training and improvement of equipment significantly increased extracorporeal membrane oxygenation results.


ResumoIntrodução:Falência ventricular pós-cardiotomia necessitando de suporte circulatório mecânico ocorre em cerca de 0,5% dos casos. Em nosso meio, o uso de ECMO tem aumentado nos últimos anos.Objetivo:Avaliar o impacto do investimento na formação profissional e melhoria dos equipamentos na taxa de desmame de ECMO e na sobrevida.Métodos:Estudo retrospectivo. Cinquenta e seis pacientes cardíacos pediátricos e/ou portadores de cardiopatias congênitas foram submetidos ao implante de ECMO pós-cardiotomia em nossa instituição entre novembro de 1999 e julho de 2014. Nós dividimos este período em duas fases: fase I, 36 casos (antes da estruturação do programa de ECMO) e fase II, 20 casos (após a instalação do programa ECMO com investimento em formação e equipamento). Foram considerados como desfechos primários: o desmame de ECMO e sobrevida até a alta hospitalar. Os resultados em ambas as fases foram comparados pelo teste Chi-quadrado. Para identificar o impacto das diferentes variáveis, ​ foi usada análise de regressão logística binária.Resultados:Na fase I, 9 pacientes (25%) foram desmamados da ECMO, mas apenas 2 (5,5%) tiveram alta. Na fase II, ECMO foi usado em 20 pacientes, o desmame foi possível em 17 deles (85%), com 9 (45%) altas hospitalares. Quando analisamos o impacto das diversas variáveis ​​sobre a sobrevida e desmame de ECMO, observa-se que a fase II foi um preditor independente de melhores resultados (P<0,001) e a necessidade de drenagem das cavidades esquerdas foi associada com pior sobrevida (P=0,045).Conclusão:O investimento na formação profissional e aperfeiçoamento de equipamentos melhorou significativamente os resultados de ECMO em nossa instituição.


Subject(s)
Female , Humans , Infant , Infant, Newborn , Male , Education, Continuing/statistics & numerical data , Extracorporeal Membrane Oxygenation/education , Transposition of Great Vessels/surgery , Extracorporeal Membrane Oxygenation/instrumentation , Extracorporeal Membrane Oxygenation/mortality , Heart Defects, Congenital/surgery , Logistic Models , Patient Discharge , Program Evaluation , Retrospective Studies , Survival Rate , Treatment Outcome