1.
Clin Chem Lab Med ; 62(7): 1339-1351, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38515344

ABSTRACT

OBJECTIVES: A reference measurement procedure (RMP) using isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) was developed and validated with the aim of accurately measuring carbamazepine-10,11-epoxide concentrations in human serum and plasma. METHODS: To establish traceability to SI units, the absolute content of the reference material was determined using quantitative nuclear magnetic resonance (qNMR) spectroscopy. As sample preparation a protein precipitation protocol followed by a high dilution step was established. Chromatographic separation from carbamazepine and potential metabolites was achieved using a C18 stationary phase. Selectivity, specificity, matrix effects, precision and accuracy, inter-laboratory equivalence, and uncertainty of measurement were evaluated based on guidelines from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the Expression of Uncertainty in Measurement. RESULTS: The RMP demonstrated very good selectivity and specificity, showing no evidence of a matrix effect. This enabled accurate quantification of carbamazepine-epoxide in the concentration range of 0.0400-12.0 µg/mL. The intermediate precision was found to be less than 2.1 %, and the repeatability coefficient of variation (CV) ranged from 1.2 to 1.8 % across all concentration levels. Regarding accuracy, the relative mean bias varied from 1.4 to 2.5 % for native serum levels and from 1.4 to 3.5 % for Li-heparin plasma levels. The measurement uncertainty for single measurements ranged from 1.6 to 2.1 %. CONCLUSIONS: In this study, we introduce a new LC-MS/MS-based candidate RMP for accurately measuring carbamazepine-10,11-epoxide in human serum and plasma. This novel method offers a traceable and dependable platform, making it suitable for standardizing routine assays and assessing clinically relevant samples.


Subject(s)
Carbamazepine , Tandem Mass Spectrometry , Humans , Tandem Mass Spectrometry/methods , Tandem Mass Spectrometry/standards , Carbamazepine/blood , Carbamazepine/analogs & derivatives , Chromatography, Liquid/methods , Chromatography, Liquid/standards , Reference Standards , Indicator Dilution Techniques , Liquid Chromatography-Mass Spectrometry
2.
Clin Chem Lab Med ; 62(7): 1327-1338, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38549258

ABSTRACT

OBJECTIVES: Primidone is an anticonvulsive drug used in the treatment of epilepsy and essential tremor. It offers beneficial effects in controlling seizures, but its usage is also associated with possible side effects. To ensure optimal therapy, it is crucial to measure its concentration through accurate quantification methods. Therefore, our main goal was to develop and validate a new reference measurement procedure (RMP) for accurately measuring primidone levels in human serum and plasma. METHODS: In our study, we focused on the separation of primidone from both known and unknown interferences using a C18 column. To achieve accurate sample preparation, we developed a protocol involving protein precipitation followed by a high dilution step. The validation of the assay and determination of measurement uncertainty were carried out following guidelines from organizations such as the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the Expression of Uncertainty in Measurement. These rigorous validation processes ensure the reliability and accuracy of our method for quantifying primidone levels in human serum and plasma samples. RESULTS: The RMP was shown to be highly selective and specific, with no evidence of matrix interference. It can be used to quantify primidone in the range of 0.150-30.0 µg/mL. Intermediate precision was less than 4.0 %, and repeatability CV ranged from 1.0 to 3.3 % across all concentration levels. The relative mean bias ranged from 0.1 to 3.9 % for native serum levels, and from -2.6 to 2.8 % for lithium-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment were 1.5-4.1 % and 0.9-1.0 %, respectively. CONCLUSIONS: In this study, we introduce an innovative LC-MS/MS-based candidate RMP specifically designed for primidone in human serum and plasma. Our RMP offers a traceable platform, facilitating the standardization of routine assays and enabling the evaluation of clinically relevant samples. With this novel approach, we aim to enhance the accuracy and reliability of primidone measurements, ultimately benefiting the field of clinical research and patient care.


Subject(s)
Primidone , Tandem Mass Spectrometry , Humans , Tandem Mass Spectrometry/methods , Tandem Mass Spectrometry/standards , Primidone/blood , Chromatography, Liquid/methods , Chromatography, Liquid/standards , Reference Standards , Reproducibility of Results , Indicator Dilution Techniques , Limit of Detection , Anticonvulsants/blood , Liquid Chromatography-Mass Spectrometry
3.
Clin Chem Lab Med ; 62(7): 1288-1300, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38105272

ABSTRACT

OBJECTIVES: To describe and validate an isotope dilution-liquid chromatograph-tandem mass spectrometry (ID-LC-MS/MS) based reference measurement procedure (RMP) for zonisamide to accurately measure serum and plasma concentrations. METHODS: Quantitative nuclear magnetic resonance (qNMR) spectroscopy was employed to determine the absolute content of the reference material used in order to establish traceability to SI units. Separation of zonisamide from known or unknown interferences was performed on a C8 column. For sample preparation a protocol based on protein precipitation in combination with a high dilution step was established. Assay validation and determination of measurement uncertainty were performed based on guidelines from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the expression of uncertainty in measurement. RESULTS: The RMP was proven to be highly selective and specific with no evidence of a matrix effect, allowing for quantification of zonisamide within the range of 1.50-60.0 µg/mL. Intermediate precision was <1.4 % and repeatability CV ranged from 0.7 to 1.2 % over all concentration levels. The relative mean bias ranged from 0.0 to 0.8 % for native serum levels and from 0.2 to 2.0 % for Li-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment ranged from 1.1 to 1.4 % and 0.8-1.0 %, respectively. CONCLUSIONS: We present a novel LC-MS/MS-based candidate RMP for zonisamide in human serum and plasma which provides a traceable and reliable platform for the standardization of routine assays and evaluation of clinically relevant samples.


Subject(s)
Isoxazoles , Tandem Mass Spectrometry , Zonisamide , Humans , Tandem Mass Spectrometry/methods , Tandem Mass Spectrometry/standards , Zonisamide/blood , Chromatography, Liquid/methods , Chromatography, Liquid/standards , Isoxazoles/blood , Reference Standards , Indicator Dilution Techniques , Blood Chemical Analysis/methods , Blood Chemical Analysis/standards , Liquid Chromatography-Mass Spectrometry
4.
Clin Chem Lab Med ; 62(7): 1314-1326, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38407268

ABSTRACT

OBJECTIVES: Phenobarbital serves as an antiepileptic drug (AED) and finds application in the treatment of epilepsy either as monotherapy or adjunctive therapy. This drug exhibits various pharmacodynamic properties that account for its beneficial effects as well as potential side effects. Accurate measurement of its concentration is critical for optimizing AED therapy through appropriate dose adjustments. Therefore, our objective was to develop and validate a new reference measurement procedure (RMP) for the accurate quantification of phenobarbital levels in human serum and plasma. METHODS: A sample preparation protocol based on protein precipitation followed by a high dilution step was established in combination with a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method using a C8 column to separate target analytes from known and unknown interferences. Assay validation and determination of measurement uncertainty were performed based on current guidelines. Selectivity and Specificity were assessed using spiked serum and plasma samples; to investigate possible matrix effects (MEs) a post-column infusion experiment and a comparison of standard line slopes was performed. Precision and accuracy were determined within a multiday precision experiment. RESULTS: The RMP was shown to be highly selective and specific, with no evidence of matrix interferences. It can be used to quantify phenobarbital in the range of 1.92 to 72.0 µg/mL. Intermediate precision was less than 3.2 %, and repeatability coefficient of variation (CV) ranged from 1.3 to 2.0 % across all concentration levels. The relative mean bias ranged from -3.0 to -0.7 % for native serum levels, and from -2.8 to 0.8 % for Li-heparin plasma levels. The measurement uncertainties (k=1) for single measurements and target value assignment were 1.9 to 3.3 % and 0.9 to 1.6 %, respectively. CONCLUSIONS: A novel LC-MS/MS-based candidate RMP for the quantification of phenobarbital in human serum and plasma is presented which can be used for the standardization of routine assays and the evaluation of clinically relevant samples.


Subject(s)
Phenobarbital , Tandem Mass Spectrometry , Humans , Phenobarbital/blood , Tandem Mass Spectrometry/methods , Tandem Mass Spectrometry/standards , Chromatography, Liquid/methods , Chromatography, Liquid/standards , Anticonvulsants/blood , Reference Standards , Blood Chemical Analysis/methods , Blood Chemical Analysis/standards , Indicator Dilution Techniques , Liquid Chromatography-Mass Spectrometry
5.
Anal Bioanal Chem ; 416(23): 5121-5131, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39046504

ABSTRACT

Accurate measurement of serum glycocholic acid (GCA) is crucial for evaluating the activity of chronic hepatitis. Moreover, GCA is a novel identified biomarker for hepatocellular carcinoma. Although some laboratories have used the liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to measure GCA in recent years, the problem of potential interference of GCA analogues has not been solved well yet. Neither reference measurement procedures nor reference materials for GCA have been listed in the Joint Committee for Traceability in Laboratory Medicine (JCTLM) database. For standardization of GCA, it is urgent to establish a candidate measurement procedure for GCA. In this study, a candidate reference measurement procedure for the quantification of GCA in human serum based on isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) by a two-step sample pretreatment of protein precipitation and MAX solid-phase extraction was developed and validated. GCA can be completely separated from its structural analogues with gradient elution in 9 min compared with short time gradients published in previous literature by Huang's group. Method validation indicated perfect quantitation precision with intra-day and inter-day values that were ≤1.30% and ≤1.80%, respectively. The method showed excellent linearity with high regression coefficients (R2 > 0.999) over a range of 0.92 ng/g-38.38 µg/g and perfect recoveries at three spiked levels (99.87-100.43%). No interference, matrix effect, and carryover were observed. Moreover, the cRMP was successfully applied to measure GCA in serum samples and compared with two immunoassays in a clinical laboratory. As a candidate reference method, this method can promote a GCA standardization program.


Subject(s)
Glycocholic Acid , Tandem Mass Spectrometry , Humans , Tandem Mass Spectrometry/methods , Chromatography, Liquid/methods , Glycocholic Acid/blood , Reference Standards , Limit of Detection , Reproducibility of Results , Indicator Dilution Techniques , Solid Phase Extraction/methods
6.
Anal Bioanal Chem ; 416(22): 4897-4906, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38953919

ABSTRACT

A candidate reference measurement procedure (RMP) for serum theophylline via isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. With a single-step precipitation pretreatment and a 6-min gradient elution, the method achieved baseline separation of theophylline and its analogs on a C18-packed column. A bracketing calibration method was used to ensure repeatable signal intensity and high measurement precision. The intra-assay and inter-assay imprecisions were 1.06%, 0.84%, 0.72% and 0.47%, 0.41%, 0.25% at concentrations of 4.22 µg/mL (23.40 µmol/L), 8.45 µg/mL (46.90 µmol/L), and 15.21 µg/mL (84.43 µmol/L), respectively. Recoveries ranged from 99.35 to 102.34%. The limit of detection (LoD) was 2 ng/mL, and the lowest limit of quantification (LLoQ) was 5 ng/mL. The linearity range extended from 0.47 to 60 µg/mL (2.61-333.04 µmol/L). No ion suppression and carry-over (< 0.68%) were observed. The relative bias for this candidate RMP that participated in 2023 External Quality Control for Reference Laboratories (RELA) conducted by the International Federation of Clinical Chemistry (IFCC) was within a range of 0.17 to 0.93%. Furthermore, two clinical immunoassay systems were compared with this candidate RMP, demonstrating good correlations. The results of the Trueness Verification Plan indicate significant differences among routine systems, highlighting the need for standardization efforts. The developed candidate RMP for serum theophylline serves as a precise reference baseline for standardizing clinical systems and assigning values to reference materials.


Subject(s)
Limit of Detection , Tandem Mass Spectrometry , Theophylline , Theophylline/blood , Tandem Mass Spectrometry/methods , Humans , Calibration , Chromatography, Liquid/methods , Reference Standards , Indicator Dilution Techniques , Reproducibility of Results
7.
Anal Bioanal Chem ; 416(13): 3117-3125, 2024 May.
Article in English | MEDLINE | ID: mdl-38589614

ABSTRACT

In this study, we demonstrate the applicability of nitrogen microwave inductively coupled atmospheric pressure mass spectrometry (MICAP-MS) for Ca, Fe, and Se quantification in human serum using isotope dilution (ID) analysis. The matrix tolerance of MICAP-MS in Na matrix was investigated, revealing that high Na levels can suppress the signal intensity. This suppression is likely due to the plasma loading and the space charge effect. Moreover, 40Ca and 44Ca isotopic fractionation was noted at elevated Na concentration. Nine certified serum samples were analyzed using both external calibration and ID analysis. Overestimation of Cr, Zn, As, and Se was found in the results of external calibration, which might result from C-induced polyatomic interference and signal enhancement, respectively. Further investigations performed with methanol showed a similar enhancement effect for Zn, As, and Se, potentially supporting this assumption. The mass concentrations determined with ID analysis show metrological compatibility with the reference values, indicating that MICAP-MS combined with ID analysis can be a promising method for precise Ca, Fe, and Se determination. Moreover, this combination reduces the influence of matrix effects, broadening the applicability of MICAP-MS for samples with complex matrixes.


Subject(s)
Atmospheric Pressure , Calcium , Iron , Mass Spectrometry , Microwaves , Nitrogen , Selenium , Humans , Iron/blood , Calcium/blood , Mass Spectrometry/methods , Selenium/blood , Indicator Dilution Techniques
8.
Anal Bioanal Chem ; 416(14): 3447-3458, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38642097

ABSTRACT

N-Terminal pro-B-type natriuretic peptide (NT-proBNP) is a pivotal biomarker for the diagnosis and prognosis of heart failure (HF). However, no SI-traceable certified reference material (CRM) or reference measurement procedure (RMP) is available for this biomarker, and so clinical testing results obtained in different laboratories cannot be traced to a higher-order standard, leading to incomparable measurements. Protein hydrolysis and protein cleavage isotope dilution mass spectrometry (AAA-IDMS and PepA-IDMS) were used to develop a CRM. Structurally related impurities were identified by high-resolution mass spectrometry. The quantitative AAA-IDMS results were corrected according to the amino acid compositions of the impurities. Using PepA-IDMS, two peptides from the proteolyzed product were confirmed as signature peptides. To obtain traceable and accurate results, the signature peptides were quantified using impurity-corrected AAA-IDMS. The candidate NT-proBNP solution was denatured and enzymatically digested using the Glu-C endoproteinase. The released signature peptides were measured using an isotopic dilution approach. The homogeneity and stability of the candidate CRM were characterized, and their uncertainties were combined with the value assignment process. The developed CRM can be considered a unique SI-traceable NT-proBNP reference material and is expected to be used as a primary calibrator for matrix NT-proBNP CRM development.


Subject(s)
Mass Spectrometry , Natriuretic Peptide, Brain , Peptide Fragments , Reference Standards , Biomarkers/blood , Biomarkers/analysis , Indicator Dilution Techniques , Mass Spectrometry/methods , Natriuretic Peptide, Brain/chemistry , Natriuretic Peptide, Brain/standards , Peptide Fragments/chemistry , Peptide Fragments/analysis
9.
Anal Bioanal Chem ; 416(20): 4635-4645, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38949681

ABSTRACT

17α-Hydroxyprogesterone (17α-OHP) quantification in dried blood spots (DBS) is essential for newborn screening for congenital adrenal hyperplasia (CAH), which is challenging due to its low physiological concentration. The high false-positive rates of immunoassays necessitate the development of more accurate methods. Liquid chromatography tandem mass spectrometry (LC-MS/MS) offers increased specificity and sensitivity, yet standardized procedures for 17α-OHP measurement are required for clinical application. A candidate reference measurement procedure (cRMP) using isotope dilution LC-MS/MS was developed for 17α-OHP quantification in DBS. By utilizing stable isotope-labeled D8-17α-OHP as an internal standard, the cRMP was optimized, covering sample preparation, calibration, and LC-MS/MS analysis. The method performance was validated across several parameters, including precision, accuracy, specificity, detection limits, and matrix effects. Clinical applicability was further assessed through the establishment of reference intervals for healthy newborns. The developed cRMP exhibited a linear range of 1.00 to 80.00 ng/mL for 17α-OHP, with detection and quantification limits of 0.14 ng/mL and 0.52 ng/mL, respectively. Inter- and intraday precision demonstrated coefficients of variation within 1.27 to 5.69%. The recovery rates and matrix effects were well within acceptable limits, ensuring method reliability. Clinical application showed distinct reference intervals for healthy newborns that were unaffected by sex but influenced by weight and gestational age. This method significantly enhances CAH diagnostic accuracy in newborns, providing a valuable tool for clinical laboratories and improving newborn screening program standardization and traceability.


Subject(s)
17-alpha-Hydroxyprogesterone , Dried Blood Spot Testing , Tandem Mass Spectrometry , Humans , Tandem Mass Spectrometry/methods , Dried Blood Spot Testing/methods , 17-alpha-Hydroxyprogesterone/blood , Infant, Newborn , Chromatography, Liquid/methods , Limit of Detection , Reference Standards , Adrenal Hyperplasia, Congenital/blood , Adrenal Hyperplasia, Congenital/diagnosis , Neonatal Screening/methods , Reproducibility of Results , Indicator Dilution Techniques , Female , Reference Values
10.
Int J Mol Sci ; 25(1)2024 Jan 04.
Article in English | MEDLINE | ID: mdl-38203831

ABSTRACT

Physicochemical examinations of very high dilution (UHD) solutions subjected to certain physical factors (such as shaking) are becoming more frequent and are increasingly producing conclusive results. A much less studied phenomenon is the transfer of molecular information (i.e., UHD signals of dilute substances) from one liquid to another without an intermediate liquid phase. The aim of this study was to investigate the possibility of such a transfer of the UHD signal from the UHD solutions to the receiver solution, in particular, if the molecular source used in the donor solutions was the biologically active antibodies to interferon-gamma molecule. We were especially interested in how the transfer of the UHD signal is affected by the time of exposure of the receiver to the donor, the distance between the two, and how the transfer is affected by activation (striking) versus exposure alone. Signal transfer was evaluated by differential measurements of electrical conductivity, ORP, pH, and UV/VIS spectroscopy of the exposed liquid. The results showed that activation strongly influences signal transfer and that this can be compensated to some extent by prolonged direct exposure. In principle, exposure time has a positive effect on signal transfer. Interestingly, the results of different distances between the donor and receiver showed similar changes in the parameters in the range of 0-4 cm, as estimated in this study. While the study mainly confirms the two hypotheses, it also raises a number of new questions and provides clues for further research.


Subject(s)
Antibodies , Interferon-gamma , Electric Conductivity , Indicator Dilution Techniques
11.
Arch Anim Nutr ; 78(1): 95-107, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38567675

ABSTRACT

The aim was to determine ileal endogenous nitrogen losses (ENL) and true ileal N-digestibility (TD-N) under non-steady-state conditions of the 15N-isotope dilution technique (15N-IDT), using diets generating low and high ENL and compare results to those obtained under steady-state conditions. Twelve growing pigs (mean LW 22.4 kg) fitted with a post-valve T-caecum cannula were fed an enzyme-hydrolysed casein (EHC)-based diet or an EHC diet + 4% quebracho tannins (QT) and were labelled via continuous 15N-leucine i.v. infusion or twice daily oral 15N-leucine administration. Digesta were collected daily over three consecutive hours with blood plasma sampled on the four consecutive days after cessation of 15N-labelling. There was a significant effect of sampling day on the dilution factor. Endogenous N losses were significantly lower for the EHC than the EHC+QT diet (2.41 vs. 8.69 g/kg DMI), while no significant effect of sampling day was observed. The TD-N of the EHC+QT diet did not differ from the TD-N of the EHC diet (95.1 vs. 92.0%). A significant effect of sampling day was observed for TD-N with day 1 and 2, being higher than day 4. Non-steady-state conditions overestimated ENL by 25-28% as compared to 3 h collections in steady-state conditions, but the relative overestimation was similar for the EHC diet as for the EHC+QT diet. TD-N did not differ significantly compared to 12 h steady-state measurements, but comparison to 3 h steady-state measurements showed that non-steady-state conditions overestimated TD-N for the EHC+QT diet by 9%. However, on day 4 this overestimation disappeared. Using the 15N-IDT during non-steady-state conditions can provide valuable additional data on endogenous N losses and TD-N.


Subject(s)
Animal Feed , Diet , Digestion , Ileum , Nitrogen Isotopes , Nitrogen , Animals , Ileum/physiology , Ileum/metabolism , Nitrogen/metabolism , Digestion/drug effects , Digestion/physiology , Diet/veterinary , Animal Feed/analysis , Animal Nutritional Physiological Phenomena , Male , Sus scrofa/physiology , Indicator Dilution Techniques/veterinary , Swine/physiology , Female
12.
J Nutr ; 153(3): 657-664, 2023 03.
Article in English | MEDLINE | ID: mdl-36931748

ABSTRACT

BACKGROUND: Direct anthropometric measurements to assess body composition have limited precision and/or specificity. OBJECTIVES: The study aimed to develop a prediction equation based on anthropometric measurements for estimating total body water (TBW) in a healthy population. METHODS: TBW was assessed using the deuterium dilution method in 398 Moroccan participants (235 women and 163 men) aged 11.6-88 y, then compared to the estimations made by previously published anthropometric equations. By sex, participants were randomly assigned into development (n = 199) and validation subgroups (n = 199). A new anthropometric equation was developed in the development subgroup from data obtained on body volume (BV), weight, and sex, where the BV was calculated from participants' height. Then the equation was validated in the validation subgroup using the Bland and Altman procedure, bias, and pure error. External validation was performed using a sample from Tunisia (n = 220, 51.8% female, 18-65 y). RESULTS: Bias in predicting TBW showed unacceptable value for all previously published equations as it was significantly overestimated. The following new equation using anthropometric measurements [TBW (kg) = -5.249 + 107.502 BV (L) + 0.289 weight (kg) + 2.015 sex (male: 1, female: 0); (R2 = 0.91, RMSE = 1.885 kg)] was developed, and its internal validation was confirmed. The generated bias and pure error values were 0.047 kg (95% CI: -0.235, 0.330) and 2.02 kg (95% CI: 1.73, 2.31), respectively. The external validation of the new TBW prediction equation on a Tunisian sample showed a bias and pure error values of 0.07 kg (95% CI: -0.289, 0.429) and 2.36 kg, respectively. CONCLUSIONS: The results indicate that the new anthropometric-based prediction equation provides a good estimation of TBW and other body composition compartments. It could be recommended as an alternative method to assess body composition for epidemiological and clinical studies.


Subject(s)
Body Composition , Body Water , Humans , Male , Female , Electric Impedance , Anthropometry/methods , Indicator Dilution Techniques
13.
Anal Biochem ; 660: 114959, 2023 01 01.
Article in English | MEDLINE | ID: mdl-36341770

ABSTRACT

RNA double strand hybridization is a hallmark for gene expression regulation. In this function, single stranded regulatory RNA forms Watson-Crick base pairs with complementary messenger RNA. In the presented work the dissociation constants of complementary equally sized RNA single strands were measured at the single molecule level applying fluorescence correlation spectroscopy (FCS). Dissociation constants of 3.2 nM, 1.4 nM and 1.0 nM were determined for 26 bp, 41 bp and 54 bp dsRNA, respectively. The translational diffusion coefficients of RNA, measured at infinite dilution, could be accurately predicted applying the model D = 4.58 × 10-10 N-0.39 m2s-1.


Subject(s)
RNA, Double-Stranded , Single Molecule Imaging , Nucleic Acid Hybridization , RNA, Messenger/genetics , Indicator Dilution Techniques
14.
Clin Chem Lab Med ; 61(11): 1955-1966, 2023 10 26.
Article in English | MEDLINE | ID: mdl-36689915

ABSTRACT

OBJECTIVES: To describe and validate a reference measurement procedure (RMP) for gabapentin, employing quantitative nuclear magnetic resonance (qNMR) spectroscopy to determine the absolute content of the standard materials in combination with isotope dilution-liquid chromatograph-tandem mass spectrometry (ID-LC-MS/MS) to accurately measure serum and plasma concentrations. METHODS: A sample preparation protocol based on protein precipitation in combination with LC-MS/MS analysis using a C8 column for chromatographic separation was established for the quantification of gabapentin. Assay validation and determination of measurement uncertainty were performed according to guidance from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the expression of uncertainty in measurement. ID-LC-MS/MS parameters evaluated included selectivity, specificity, matrix effects, precision and accuracy, inter-laboratory equivalence, and uncertainty of measurement. RESULTS: The use of qNMR provided traceability to International System (SI) units. The chromatographic assay was highly selective, allowing baseline separation of gabapentin and the gabapentin-lactam impurity, without observable matrix effects. Variability between injections, preparations, calibrations, and days (intermediate precision) was <2.3%, independent of the matrix, while the coefficient of variation for repeatability was 0.9-2.0% across all concentration levels. The relative mean bias ranged from -0.8-1.0% for serum and plasma samples. Passing-Bablok regression analysis indicated very good inter-laboratory agreement; the slope was 1.00 (95% confidence interval [CI] 0.98 to 1.03) and the intercept was -0.05 (95% CI -0.14 to 0.03). Pearson's correlation coefficient was ≥0.996. Expanded measurement uncertainties for single measurements were found to be ≤5.0% (k=2). CONCLUSIONS: This analytical protocol for gabapentin, utilizing traceable and selective qNMR and ID-LC-MS/MS techniques, allows for the standardization of routine tests and the reliable evaluation of clinical samples.


Subject(s)
Plasma , Tandem Mass Spectrometry , Humans , Chromatography, Liquid/methods , Gabapentin , Tandem Mass Spectrometry/methods , Indicator Dilution Techniques , Isotopes , Reference Standards
15.
Clin Chem Lab Med ; 61(11): 1902-1916, 2023 10 26.
Article in English | MEDLINE | ID: mdl-36952682

ABSTRACT

OBJECTIVES: An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC MS/MS)-based candidate reference measurement procedure (RMP) for aldosterone quantification in human serum and plasma is presented. METHODS: The material used in this RMP was characterized by quantitative nuclear magnetic resonance (qNMR) to assure traceability to SI Units. For liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis a two-dimensional heart cut LC approach, in combination with an optimal supported liquid extraction protocol, was established for the accurate analysis of aldosterone in human serum and plasma in order to minimize matrix effects and avoid the co-elution of interferences. Assay validation was performed according to current guidelines. Selectivity and specificity were assessed using spiked serum; potential matrix effects were examined by a post column infusion experiment and the comparison of standard line slopes. An extensive protocol over 5 days was applied to determine precision, accuracy and trueness. Measurement uncertainty was evaluated according to the Guide to the Expression of Uncertainty in Measurement (GUM), for which three individual sample preparations were performed on at least two different days. RESULTS: The RMP allowed aldosterone quantification within the range of 20-1,200 pg/mL without interference from structurally-related compounds and no evidence of matrix effects. Intermediate precision was ≤4.7% and repeatability was 2.8-3.7% for all analyte concentrations. The bias ranged between -2.2 and 0.5% for all levels and matrices. Total measurement uncertainties for target value assignment (n=6) were found to be ≤2.3%; expanded uncertainties were ≤4.6% (k=2) for all levels. CONCLUSIONS: The RMP showed high analytical performance for aldosterone quantification in human serum and plasma. The traceability to SI units was established by qNMR content determination of aldosterone, which was utilized for direct calibration of the RMP. Thus, this candidate RMP is suitable for routine assay standardization and evaluation of clinical samples.


Subject(s)
Aldosterone , Tandem Mass Spectrometry , Humans , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Isotopes , Indicator Dilution Techniques , Reference Standards
16.
Clin Chem Lab Med ; 61(11): 1942-1954, 2023 10 26.
Article in English | MEDLINE | ID: mdl-37466369

ABSTRACT

OBJECTIVES: Topiramate is an antiepileptic drug (AED) used for the monotherapy or adjunctive treatment of epilepsy and for the prophylaxis of migraine. It has several pharmacodynamic properties that contribute to both its clinically useful properties and observed adverse effects. Accurate measurement of its concentration is therefore essential for dose adjustment/optimisation of AED therapy. Our aim was to develop and validate a novel reference measurement procedure (RMP) for the quantification of topiramate in human serum and plasma. METHODS: An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) method in combination with a protein-precipitation-based sample preparation allows for quantification of topiramate in human serum and plasma. To assure traceability to SI units, quantitative nuclear magnetic resonance (qNMR) was applied to characterize the reference material used as primary calibrator for this RMP. Matrix effects were determined by performing a post-column infusion experiment and comparing standard line slopes. Accuracy and precision was evaluated performing an extensive five day precision experiment and measurement uncertainty was evaluated according Guide to the Expression of Uncertainty in Measurement (GUM). RESULTS: The method enabled topiramate quantification within the range of 1.20-36.0 µg/mL without interference from structurally related compounds and no evidence of a matrix effect. Intermediate precision was ≤3.2 % and repeatability was 1.4-2.5 % across all concentration levels. The relative mean bias was -0.3 to 3.5 %. Expanded measurement uncertainties for target value assignment (n=6) were found to be ≤2.9 % (k=2) independent of the concentration level and the nature of the sample. CONCLUSIONS: In human serum and plasma, the RMP demonstrated high analytical performance for topiramate quantification and fulfilled the requirements on measurement uncertainty. Traceability to SI units was established by qNMR content determination of the topiramate, which was used for direct calibration of the RMP. This RMP is, therefore, fit for purpose for routine assay standardization and clinical sample evaluation.


Subject(s)
Plasma , Tandem Mass Spectrometry , Humans , Chromatography, Liquid/methods , Topiramate , Tandem Mass Spectrometry/methods , Indicator Dilution Techniques , Anticonvulsants , Isotopes , Reference Standards
17.
Clin Chem Lab Med ; 61(11): 1917-1929, 2023 10 26.
Article in English | MEDLINE | ID: mdl-36788118

ABSTRACT

OBJECTIVES: To develop an isotope dilution-liquid chromatography-tandem mass spectrometry-(ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for quantification of methotrexate in human serum and plasma. METHODS: Quantitative nuclear magnetic resonance (qNMR) was used to determine absolute methotrexate content in the standard. Separation was achieved on a biphenyl reversed-phase analytical column with mobile phases based on water and acetonitrile, both containing 0.1% formic acid. Sample preparation included protein precipitation in combination with high sample dilution, and method validation according to current guidelines. The following were assessed: selectivity (using analyte-spiked samples, and relevant structural-related compounds and interferences); specificity and matrix effects (via post-column infusion and comparison of human matrix vs. neat samples); precision and accuracy (in a five-day validation analysis). RMP results were compared between two independent laboratories. Measurement uncertainty was evaluated according to current guidelines. RESULTS: The RMP separated methotrexate from potentially interfering compounds and enabled measurement over a calibration range of 7.200-5,700 ng/mL (0.01584-12.54 µmol/L), with no evidence of matrix effects. All pre-defined acceptance criteria were met; intermediate precision was ≤4.3% and repeatability 1.5-2.1% for all analyte concentrations. Bias was -3.0 to 2.1% for samples within the measuring range and 0.8-4.5% for diluted samples, independent of the sample matrix. RMP results equivalence was demonstrated between two independent laboratories (Pearson correlation coefficient 0.997). Expanded measurement uncertainty of target value-assigned samples was ≤3.4%. CONCLUSIONS: This ID-LC-MS/MS-based approach provides a candidate RMP for methotrexate quantification. Traceability of methotrexate standard and the LC-MS/MS platform were assured by qNMR assessment and extensive method validation.


Subject(s)
Methotrexate , Tandem Mass Spectrometry , Humans , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Indicator Dilution Techniques , Isotopes , Reference Standards , Reproducibility of Results
18.
Clin Chem Lab Med ; 61(11): 1967-1977, 2023 10 26.
Article in English | MEDLINE | ID: mdl-37011038

ABSTRACT

OBJECTIVES: To develop an isotope dilution-liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based candidate reference measurement procedure (RMP) for levetiracetam quantification in human serum and plasma. METHODS: Quantitative nuclear magnetic resonance spectroscopy (qNMR) was used to characterize the RMP material to ensure traceability to SI units. To quantify levetiracetam, an LC-MS/MS method was optimized using a C8 column for chromatographic separation following protein-precipitation-based sample preparation. Spiked matrix samples of serum and plasma were used to test selectivity and specificity. Matrix effects were determined by performing a post-column infusion experiment and comparing standard line slopes. Precision and accuracy were evaluated over 5 days. Measurement uncertainty was evaluated according to the Guide to the Expression of Uncertainty in Measurement (GUM). RESULTS: The RMP was proven to be highly selective and specific with no evidence of a matrix effect, allowing for quantification of levetiracetam within the range of 1.53-90.0 µg/mL. Intermediate precision was <2.2% and repeatability was 1.1-1.7% across all concentrations. The relative mean bias ranged from -2.5% to -0.3% across all levels and matrices within the measuring range. Diluted samples were found with a mean bias ranging from -0.1 to 2.9%. The predefined acceptance criterion for measurement uncertainty was met and determined for individual measurements independently of the concentration level and sample type to be ≤4.0% (k=2). CONCLUSIONS: We present a novel LC-MS/MS)-based candidate RMP for levetiracetam in human serum and plasma. Its expanded measurement uncertainty of ≤4.0% meets the clinical needs in levetiracetam monitoring. Utilizing qNMR to characterize levetiracetam reference materials allowed metrological traceability to SI units.


Subject(s)
Isotopes , Tandem Mass Spectrometry , Humans , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Levetiracetam , Reproducibility of Results , Indicator Dilution Techniques , Reference Standards
19.
Anal Bioanal Chem ; 415(19): 4795-4804, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37291250

ABSTRACT

Here we proposed a method for peptide purity analysis using gas chromatography-isotope dilution infrared spectroscopy. The principle and feasibility of the proposed measurement method were investigated. The derivatization, separation, and infrared detection conditions for amino acids were optimized, and the performance of the method was investigated. Then, the proposed method was used for assessment of [Glu1]-fibrinopeptide B purity, and the results were compared with those obtained by high performance liquid chromatography-isotope dilution mass spectrometry. The average purity of six sub-samples using the proposed method was (0.755 ± 0.017) g/g, which agreed well with that obtained by isotope dilution mass spectrometry (0.754 ± 0.012) g/g. The repeatability of the proposed method was 2.2%, which was similar to that of isotope dilution mass spectrometry (1.7%). The proposed method has a similar principle and had similar accuracy, precision, and linearity to isotope dilution mass spectrometry; however, the developed method had higher limit of detection (LOD) and limit of quantitation (LOQ) values because of the low sensitivity of infrared detection. The results were also Système International d'Unités (SI) traceable. The developed method has the advantage of lower cost compared with isotope dilution mass spectrometry because only one isotope-labeled atom in an analog is required, and several infrared spectra can be extracted, averaged, and used for an amino acid calculation during one run, potentially leading to higher accuracy. This method could be easily expanded to the accurate quantitation of other organic compounds, including proteins. It is expected that the proposed method will be widely used in chemical and biological measurements as a new primary method.


Subject(s)
Isotopes , Peptides , Gas Chromatography-Mass Spectrometry/methods , Mass Spectrometry/methods , Indicator Dilution Techniques , Amino Acids/analysis , Spectrum Analysis
20.
Anal Bioanal Chem ; 415(23): 5637-5644, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37490154

ABSTRACT

We developed and evaluated two-level, namely 2017011 and 2017012, serum-based reference materials (RMs) for 17 beta-estradiol (17 ß-E2) by the reference method of isotope dilution liquid chromatography tandem mass spectrometry (ID-LC-MS/MS) from the remaining serum samples after routine clinical tests, to help improve clinical routine testing and provide the traceability of results. This paper describes the development process of these RMs. The National Metrology Institute of Japan (NMIJ) certified reference material (CRM) 6004-a was used as the primary RM for the measurement of 17 ß-E2. These serum-based RMs showed satisfactory homogeneity and stability. They also assessed the commutability between the reference method and the three routine clinical immunoassay systems. Besides, a collaborative study was carried out in five reference laboratories, all of which had been accredited by the China National Accreditation Service for Conformity Assessment (CNAS) in accordance with ISO/WD 15725-1. Statistical analysis of raw results and uncertainty assessment obtained certified values: 2017011 was 445.2 ± 39.0 pmol/L, and 2017012 was 761.9 ± 35.5 pmol/L.


Subject(s)
Estradiol , Tandem Mass Spectrometry , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Indicator Dilution Techniques , Isotopes , Reference Standards