Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 970
Filter
Add more filters

Publication year range
1.
J Biol Chem ; 300(3): 105676, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38278326

ABSTRACT

Infectious diseases are one of the world's leading causes of morbidity. Their rapid spread emphasizes the need for accurate and fast diagnostic methods for large-scale screening. Here, we describe a robust method for the detection of pathogens based on microscale thermophoresis (MST). The method involves the hybridization of a fluorescently labeled DNA probe to a target RNA and the assessment of thermophoretic migration of the resulting complex in solution within a 2 to 30-time window. We found that the thermophoretic migration of the nucleic acid-based probes is primarily determined by the fluorescent molecule used, rather than the nucleic acid sequence of the probe. Furthermore, a panel of uniformly labeled probes that bind to the same target RNA yields a more responsive detection pattern than a single probe, and moreover, can be used for the detection of specific pathogen variants. In addition, intercalating agents (ICA) can be used to alter migration directionality to improve detection sensitivity and resolving power by several orders of magnitude. We show that this approach can rapidly diagnose viral SARS-CoV2, influenza H1N1, artificial pathogen targets, and bacterial infections. Furthermore, it can be used for anti-microbial resistance testing within 2 h, demonstrating its diagnostic potential for early pathogen detection.


Subject(s)
High-Throughput Screening Assays , Microbiological Techniques , Molecular Diagnostic Techniques , Nucleic Acid Hybridization , RNA , DNA Probes , Influenza A Virus, H1N1 Subtype/genetics , Influenza A Virus, H1N1 Subtype/isolation & purification , Molecular Diagnostic Techniques/methods , Molecular Diagnostic Techniques/standards , Microbiological Techniques/methods , Microbiological Techniques/standards , High-Throughput Screening Assays/methods , High-Throughput Screening Assays/standards , RNA/analysis , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , Virus Diseases/diagnosis , Bacterial Infections/diagnosis , Cell Line, Tumor , Humans
2.
Clin Infect Dis ; 78(5): 1313-1320, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38306491

ABSTRACT

BACKGROUND: Sputum-based testing is a barrier to increasing access to molecular diagnostics for tuberculosis (TB). Many people with TB are unable to produce sputum, and sputum processing increases assay complexity and cost. Tongue swabs are emerging as an alternative to sputum, but performance limits are uncertain. METHODS: From June 2022 to July 2023, we enrolled 397 consecutive adults with cough >2 weeks at 2 health centers in Kampala, Uganda. We collected demographic and clinical information, sputum for TB testing (Xpert MTB/RIF Ultra and 2 liquid cultures), and tongue swabs for same-day quantitative polymerase chain reaction (qPCR) testing. We evaluated tongue swab qPCR diagnostic accuracy versus sputum TB test results, quantified TB targets per swab, assessed the impact of serial swabbing, and compared 2 swab types (Copan FLOQSWAB and Steripack spun polyester). RESULTS: Among 397 participants, 43.1% were female, median age was 33 years, 23.5% were diagnosed with human immunodeficiency virus, and 32.0% had confirmed TB. Sputum Xpert Ultra and tongue swab qPCR results were concordant for 98.2% (95% confidence interval [CI]: 96.2-99.1) of participants. Tongue swab qPCR sensitivity was 92.6% (95% CI: 86.5 to 96.0) and specificity was 99.1% (95% CI: 96.9 to 99.8) versus microbiological reference standard. A single tongue swab recovered a 7-log range of TB copies, with a decreasing recovery trend among 4 serial swabs. Swab types performed equivalently. CONCLUSIONS: Tongue swabs are a promising alternative to sputum for molecular diagnosis of TB, with sensitivity approaching sputum-based molecular tests. Our results provide valuable insights for developing successful tongue swab-based TB diagnostics.


Subject(s)
Mycobacterium tuberculosis , Real-Time Polymerase Chain Reaction , Sensitivity and Specificity , Specimen Handling , Sputum , Tongue , Humans , Female , Sputum/microbiology , Male , Uganda , Adult , Tongue/microbiology , Specimen Handling/methods , Mycobacterium tuberculosis/genetics , Mycobacterium tuberculosis/isolation & purification , Real-Time Polymerase Chain Reaction/methods , Molecular Diagnostic Techniques/methods , Molecular Diagnostic Techniques/standards , Tuberculosis/diagnosis , Tuberculosis/microbiology , Middle Aged , Young Adult , Tuberculosis, Pulmonary/diagnosis , Tuberculosis, Pulmonary/microbiology
3.
Clin Infect Dis ; 78(7): e385-e415, 2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38112284

ABSTRACT

Accurate molecular diagnostic tests are necessary for confirming a diagnosis of coronavirus disease 2019 (COVID-19) and for identifying asymptomatic carriage of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The number of available SARS-CoV-2 nucleic acid detection tests continues to increase as does the COVID-19 diagnostic literature. Thus, the Infectious Diseases Society of America (IDSA) developed an evidence-based diagnostic guideline to assist clinicians, clinical laboratorians, patients, and policymakers in decisions related to the optimal use of SARS-CoV-2 nucleic acid amplification tests. In addition, we provide a conceptual framework for understanding molecular diagnostic test performance, discuss nuances of test result interpretation in a variety of practice settings, and highlight important unmet research needs related to COVID-19 diagnostic testing. IDSA convened a multidisciplinary panel of infectious diseases clinicians, clinical microbiologists, and experts in systematic literature review to identify and prioritize clinical questions and outcomes related to the use of SARS-CoV-2 molecular diagnostics. Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology was used to assess the certainty of evidence and make testing recommendations. The panel agreed on 12 diagnostic recommendations. Access to accurate SARS-CoV-2 nucleic acid testing is critical for patient care, hospital infection prevention, and the public health response to COVID-19 infection. Information on the clinical performance of available tests continues to grow, but the quality of evidence of the current literature to support this updated molecular diagnostic guideline remains moderate to very low. Recognizing these limitations, the IDSA panel weighed available diagnostic evidence and recommends nucleic acid testing for all symptomatic individuals suspected of having COVID-19. In addition, testing is suggested for asymptomatic individuals with known or suspected contact with a COVID-19 case when the results will impact isolation/quarantine/personal protective equipment (PPE) usage decisions. Evidence in support of rapid testing and testing of upper respiratory specimens other than nasopharyngeal swabs, which offer logistical advantages, is sufficient to warrant conditional recommendations in favor of these approaches.


Subject(s)
COVID-19 Nucleic Acid Testing , COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , COVID-19 Nucleic Acid Testing/standards , COVID-19 Nucleic Acid Testing/methods , United States , Molecular Diagnostic Techniques/standards , Molecular Diagnostic Techniques/methods , COVID-19 Testing/methods , COVID-19 Testing/standards , Nucleic Acid Amplification Techniques/standards , Nucleic Acid Amplification Techniques/methods
4.
J Clin Microbiol ; 62(5): e0024324, 2024 May 08.
Article in English | MEDLINE | ID: mdl-38629844

ABSTRACT

Detection of bacterial RNA by nucleic acid amplification tests (NAATs), such as reverse transcription PCR (RT-PCR) and reverse transcription loop-mediated isothermal amplification (RT-LAMP), offers distinct advantages over DNA-based methods. However, such assays also present challenges in ascertaining positive and internal control material that can reliably monitor success over all phases of testing (bacterial lysis, nucleic acid recovery, reverse transcription, amplification, and signal detection): since they are unable to distinguish between amplification of bacterial RNA transcripts and the DNA templates that encode them, using intact organisms as controls can inform cell lysis but not successful detection of RNA. We developed a control strategy for RNA-based bacterial NAATs that allows ready discrimination of RNA from DNA templates using self-splicing bacterial introns, such that those nucleic acids ultimately encode different sequences. We engineered two vectors encoding synthetic transgenes based on this principle, one that is active in the Gram-negative bacterium Escherichia coli and one that functions in both E. coli and the Gram-positive organism Staphylococcus aureus. We subsequently designed RT-LAMP assays that either target RNA and DNA from transgenic organisms or target RNA exclusively and demonstrated the specificity of amplification using purified nucleic acids. Using multiplex fluorescent RT-LAMP of heat-lysed specimens, we showed the practicality of deploying such transgenic organisms as an internal control to ascertain sample integrity and assay performance during clinical diagnostic testing. Our approach has broad utility for RNA-based bacterial NAATs, especially point-of-care assays and other applications where nucleic acids are nonspecifically liberated for testing.


Subject(s)
Escherichia coli , Molecular Diagnostic Techniques , Nucleic Acid Amplification Techniques , RNA, Bacterial , Reverse Transcription , Staphylococcus aureus , Nucleic Acid Amplification Techniques/methods , Escherichia coli/genetics , RNA, Bacterial/genetics , Staphylococcus aureus/genetics , Molecular Diagnostic Techniques/methods , Molecular Diagnostic Techniques/standards , Humans , Sensitivity and Specificity , Reference Standards
5.
J Clin Microbiol ; 62(6): e0015824, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38690882

ABSTRACT

Candida auris is a multidrug-resistant opportunistic fungal pathogen capable of causing serious infections and healthcare-associated outbreaks. Screening for colonization with C. auris has become routine and is recommended in many hospitals and healthcare facilities as an infection control and prevention strategy. Subsequently, and since there are currently no FDA-approved tests for this purpose, clinical microbiology laboratories have become responsible for developing protocols to detect C. auris using axial and inguinal screening swabs. In a College of American Pathologists-accredited large academic healthcare center setting, we implemented a laboratory-developed nucleic-acid amplification test for the detection of C. auris DNA. Our test validation evaluated the performance of the DiaSorin C. auris primer set used in a real-time qualitative PCR assay on the LIAISON MDX thermocycler with the Simplexa Universal Disc. The assay was highly sensitive and specific, with a limit of detection of 1-2 CFU/reaction, with no observed cross-reactivity with other Candida spp., bacterial skin commensal organisms or commonly encountered viruses. When run in parallel with a culture-based detection method, the PCR assay was 100% sensitive and specific. The assay was precise, with low variability between replicates within and between runs. Lastly, pre-analytical factors, including swab storage time, temperature, and transport media, were assessed and found to have no significant effect on the detection of C. auris at variable concentrations. Taken together, this study expands the available options for nucleic acid detection of C. auris and characterizes pre-analytical factors for implementation in both high- and low-volume laboratory settings. IMPORTANCE: This study overviews the validation and implementation of a molecular screening tool for the detection of Candida auris in a College of American Pathologist-accredited clinical laboratory. This molecular laboratory-developed test is both highly sensitive and specific and has significant health-system cost-savings associated with significantly reduced turn-around-time compared to traditional standard-of-care culture-based work up. This method and workflow is of interest to support clinical microbiology diagnostics and to help aid in hospital inpatient, and infection prevention control screening.


Subject(s)
Candida auris , Candidiasis , Real-Time Polymerase Chain Reaction , Sensitivity and Specificity , Humans , Real-Time Polymerase Chain Reaction/methods , Candidiasis/diagnosis , Candidiasis/microbiology , Candida auris/genetics , Mass Screening/methods , Inpatients , Molecular Diagnostic Techniques/methods , Molecular Diagnostic Techniques/standards , Hospitals , Candida/genetics , Candida/isolation & purification , DNA, Fungal/genetics
6.
J Clin Microbiol ; 62(6): e0034524, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38757981

ABSTRACT

Viral enrichment by probe hybridization has been reported to significantly increase the sensitivity of viral metagenomics. This study compares the analytical performance of two targeted metagenomic virus capture probe-based methods: (i) SeqCap EZ HyperCap by Roche (ViroCap) and (ii) Twist Comprehensive Viral Research Panel workflow, for diagnostic use. Sensitivity, specificity, and limit of detection were analyzed using 25 synthetic viral sequences spiked in increasing proportions of human background DNA, eight clinical samples, and American Type Culture Collection (ATCC) Virome Virus Mix. Sensitivity and specificity were 95% and higher for both methods using the synthetic and reference controls as gold standard. Combining thresholds for viral sequence read counts and genome coverage [respectively 500 reads per million (RPM) and 10% coverage] resulted in optimal prediction of true positive results. Limits of detection were approximately 50-500 copies/mL for both methods as determined by ddPCR. Increasing proportions of spike-in cell-free human background sequences up to 99.999% (50 ng/mL) did not negatively affect viral detection, suggesting effective capture of viral sequences. These data show analytical performances in ranges applicable to clinical samples, for both probe hybridization metagenomic approaches. This study supports further steps toward more widespread use of viral metagenomics for pathogen detection, in clinical and surveillance settings using low biomass samples. IMPORTANCE: Viral metagenomics has been gradually applied for broad-spectrum pathogen detection of infectious diseases, surveillance of emerging diseases, and pathogen discovery. Viral enrichment by probe hybridization methods has been reported to significantly increase the sensitivity of viral metagenomics. During the past years, a specific hybridization panel distributed by Roche has been adopted in a broad range of different clinical and zoonotic settings. Recently, Twist Bioscience has released a new hybridization panel targeting human and animal viruses. This is the first report comparing the performance of viral metagenomic hybridization panels.


Subject(s)
Metagenomics , Sensitivity and Specificity , Viruses , Humans , Metagenomics/methods , Metagenomics/standards , Viruses/genetics , Viruses/isolation & purification , Viruses/classification , Virus Diseases/diagnosis , Virus Diseases/virology , Reference Standards , Molecular Diagnostic Techniques/methods , Molecular Diagnostic Techniques/standards , Limit of Detection , Nucleic Acid Hybridization/methods , Virome
7.
J Clin Microbiol ; 62(7): e0052424, 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-38934589

ABSTRACT

This study compared the performance of two commercial molecular assays, the STANDARD M10 Clostridioides difficile assay (M10) and the Xpert C. difficile assay (Xpert), for detecting toxigenic C. difficile in stool specimens. A total of 487 consecutive stool specimens submitted for routine C. difficile testing between June and November 2023 were included. Following routine testing using C. DIFF QUIK CHEK COMPLETE (QCC), M10 and Xpert were tested in parallel, alongside toxigenic culture (reference standard). Additionally, two-step algorithms, using QCC on the first step and either M10 or Xpert on the second step, were assessed. Both M10 and Xpert demonstrated a sensitivity and negative predictive value (NPV) of 100%. M10 exhibited significantly higher specificity and positive predictive value (PPV; 91.9% and 64.2%, respectively) than Xpert (90.3% and 59.8%, respectively). Both two-step algorithms showed a sensitivity and NPV of 98.4% and 99.8%, respectively. The specificity and PPV of the two-step algorithm using M10 (95.2% and 75.0%, respectively) were slightly higher than those of the one using Xpert (94.8% and 73.2%, respectively), without statistical significance. Receiver operating characteristic curve analysis, assessing the predictive ability of cycle threshold (Ct) values for the detection of free toxin, exhibited an area under the curve of 0.825 for M10 and 0.843 for Xpert. This indicates the utility of Ct values as predictors for the detection of free toxin in both assays. In conclusion, M10 proves to be an effective diagnostic tool with performance comparable to Xpert, whether utilized independently or as part of a two-step algorithm.


Subject(s)
Clostridioides difficile , Clostridium Infections , Feces , Molecular Diagnostic Techniques , Sensitivity and Specificity , Humans , Clostridioides difficile/isolation & purification , Clostridioides difficile/genetics , Feces/microbiology , Clostridium Infections/diagnosis , Clostridium Infections/microbiology , Molecular Diagnostic Techniques/methods , Molecular Diagnostic Techniques/standards , Algorithms , Bacterial Toxins/analysis , Bacterial Toxins/genetics , Predictive Value of Tests
8.
J Clin Microbiol ; 62(6): e0060024, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38785448

ABSTRACT

The COVID-19 pandemic highlighted the necessity of fast, sensitive, and efficient methods to test large populations for respiratory viruses. The "gold standard" molecular assays for detecting respiratory viruses, such as quantitative polymerase chain reaction (qPCR) and reverse transcription qPCR (RT-qPCR), rely on invasive swab samples and require time-consuming and labor-intensive extraction processes. Moreover, the turnaround time for RT-qPCR-based assays is too lengthy for rapid screening. Extraction-free saliva-based methods provide a non-invasive sampling process with a fast turnaround time and are suitable for high-throughput applications. However, when used with a standard RT-qPCR system, the absence of extraction significantly reduces the assays' sensitivity. Here, using a novel optical modulation biosensing (OMB) platform, we developed a rapid and highly sensitive extraction-free saliva-based molecular assay. We blindly tested 364 paired nasopharyngeal swabs and saliva samples from suspected SARS-CoV-2 cases in Israel. Compared with the gold standard swab-based RT-qPCR assay, the sensitivity of the extraction-free saliva-based OMB assay is 90.7%, much higher than the sensitivity of extraction-free saliva-based RT-qPCR assay (77.8%) with similar specificity (95.3% and 97.6%, respectively). Moreover, out of 12 samples identified by the OMB-based assay as positive, 8 samples were collected from hospitalized patients in a COVID-19 ward and were verified to be SARS-CoV-2-positive upon admission, indicating that the actual clinical sensitivity and specificity of the OMB assay are higher. Considering its user-friendly saliva-based protocol, short and cost-effective extraction-free process, and high clinical accuracy, the OMB-based molecular assay is very suitable for high-throughput testing of large populations for respiratory viruses. IMPORTANCE: Three years after the SARS-CoV-2 outbreak, there are no molecular tests that combine low-cost and straightforward sample preparation, effective sample handling, minimal reagent and disposable requirements, high sensitivity, and high throughput required for mass screening. Existing rapid molecular techniques typically sacrifice certain requirements to meet others. Yet, localized outbreaks of novel viral diseases happen daily in different parts of the world. In this context, respiratory diseases are of specific importance, as they are frequently airborne and highly contagious, with the potential for a rapid global spread. The widely accepted opinion is that another pandemic is just a question of time. To ensure that the containment efforts for the upcoming "disease X" are successful, introducing rapid, high-throughput, and highly sensitive diagnostic methods for detecting and identifying pathogens is critical. A few months into the pandemic, saliva was suggested as a diagnostic matrix for SARS-CoV-2 detection. The collection of saliva does not require swabs and is minimally invasive. In particular, extraction-free saliva-based assays require fewer reagents and disposables, and therefore are faster and cheaper, offering an appealing alternative for low-income countries. Unfortunately, current extraction-free saliva-based detection methods, such as direct RT-qPCR or isothermal amplification, have either low sensitivity or low throughput. Therefore, we believe that the presented highly sensitive ht-OMBi platform and the extraction-free saliva-based molecular assay can become an essential tool in the infectious disease monitoring toolbox.


Subject(s)
COVID-19 , Nasopharynx , SARS-CoV-2 , Saliva , Sensitivity and Specificity , Humans , Saliva/virology , COVID-19/diagnosis , SARS-CoV-2/isolation & purification , SARS-CoV-2/genetics , Nasopharynx/virology , Molecular Diagnostic Techniques/methods , Molecular Diagnostic Techniques/standards , COVID-19 Nucleic Acid Testing/methods , Adult , Specimen Handling/methods , Middle Aged , Israel , Aged , Female , Male
9.
J Clin Microbiol ; 62(8): e0026724, 2024 Aug 14.
Article in English | MEDLINE | ID: mdl-39046255

ABSTRACT

Guidelines recommend monitoring of Epstein-Barr virus (EBV) and BK virus (BKV) in solid organ and hematopoietic stem cell transplant patients. The majority of quantitative DNA testing for EBV and BKV employs unstandardized individual laboratory-developed testing solutions (LDTs), with implications for accuracy, reproducibility, and comparability between laboratories. The performance of the cobas EBV and cobas BKV assays was assessed across five laboratories, using the World Health Organization International Standards (WHO IS) for EBV and BKV, and the National Institute of Standards and Technology Quantitative Standard for BKV, and results were compared with the LDTs in use at the time. Methods were also compared using locally sourced clinical specimens. Variation was high when laboratories reported EBV or BKV DNA values using LDTs, where quantitative values were observed to differ by up to 1.5 log10 unit/mL between sites. Conversely, results from the cobas EBV and cobas BKV assays were accurate and reproducible across sites and on different testing days. Adjustment of LDTs using the international standards led to closer alignment between the assays; however, day-to-day reproducibility of LDTs remained high. In addition, BKV continued to show bias, indicating challenges with the commutability of the BKV International Standard. The cobas EBV and cobas BKV assays are automated, aligned to the WHO IS, and have the potential to reduce the variability in viral load testing introduced by differences in LDTs. Standardization of reporting values may eventually allow different centers to compare data to allow clinical decision thresholds to be established supporting improvements in patient management.IMPORTANCEThe application of center-specific cut-offs for clinical decisions and the variability of LDTs often hinder interpretation; thus, the findings reported here support the need for standardization in the field of post-transplant monitoring of EBV and BKV to improve patient management. Alongside the choice of assay, it is also important to consider which standard to use when deciding upon a testing methodology. This is a call to action for standardization, as treatment for EBV and BKV is driven by viral load test results, and the more accurate and comparable the test results are across institutions, the more informed and better the treatment decisions can be.


Subject(s)
BK Virus , Epstein-Barr Virus Infections , Herpesvirus 4, Human , Viral Load , Humans , BK Virus/isolation & purification , BK Virus/genetics , Herpesvirus 4, Human/genetics , Herpesvirus 4, Human/isolation & purification , Viral Load/standards , Viral Load/methods , Reproducibility of Results , Epstein-Barr Virus Infections/diagnosis , Epstein-Barr Virus Infections/virology , Polyomavirus Infections/diagnosis , Polyomavirus Infections/virology , DNA, Viral/genetics , DNA, Viral/analysis , Molecular Diagnostic Techniques/standards , Molecular Diagnostic Techniques/methods , Tumor Virus Infections/diagnosis , Tumor Virus Infections/virology
10.
J Med Virol ; 96(6): e29688, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38847316

ABSTRACT

To meet the screening goal of WHO's 90-70-90 strategy aimed at eliminating cervical cancer (CC) by 2030, clinical validation of human papillomavirus (HPV) assays is essential to provide accurate and valid results through fulfilling three criteria of the international validation guidelines (IVGs). Previously, the clinical accuracy of the AmpFire® HPV Screening 16/18/HR assay (AmpFire assay) was reported but reproducibility data are lacking. Here, we aim to evaluate the intra- and inter-laboratory reproducibility of the AmpFire assay. The reproducibility of the isothermal AmpFire assay was assessed using 556 cervical cell samples collected from women attending CC screening and biobanked in a Belgian HPV national reference center. This assay detects HPV16, HPV18, and 12 other high-risk HPV (hrHPV) types (31/33/35/39/45/51/52/56/58/59/66/68) in aggregate. Lower 95% confidence interval bound around the assay's reproducibility should exceed 87%, with κ ≥ 0.50. Additionally, a literature review of the assay's clinical performance was performed. The AmpFire assay showed an excellent intralaboratory (96.4%, 95% CI:94.5-97.8%, κ = 0.920) and interlaboratory (95.3%, 95% CI:93.2-96.9%, κ = 0.897) reproducibility. One study demonstrated noninferior sensitivity of a prototype AmpFire assay targeting 15 hrHPV types (including HPV53) to detect CIN2+. However, clinical specificity became similar to the comparator after removing HPV53 from analyses. The low-cost and easy-to-use AmpFire assay presents excellent reproducibility and-after removing HPV53 from the targeted types-fulfills also clinical accuracy requirements. Inclusion of HPV53, which is not recognized as carcinogenic, comprises clinical specificity of screening assays.


Subject(s)
Papillomavirus Infections , Uterine Cervical Neoplasms , Humans , Reproducibility of Results , Papillomavirus Infections/diagnosis , Papillomavirus Infections/virology , Female , Uterine Cervical Neoplasms/diagnosis , Uterine Cervical Neoplasms/virology , Papillomaviridae/isolation & purification , Belgium , Early Detection of Cancer/methods , Early Detection of Cancer/standards , Adult , Sensitivity and Specificity , Middle Aged , Molecular Diagnostic Techniques/standards , Molecular Diagnostic Techniques/methods , Cervix Uteri/virology
11.
Eur J Clin Microbiol Infect Dis ; 43(8): 1597-1607, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38833104

ABSTRACT

PURPOSE: To comprehensively investigate the diagnostic performance of routinely used assays in MPXV testing, the National Center of Clinical Laboratories in China conducted a nationwide external quality assessment (EQA) scheme and an evaluated nine assays used by ≥ 5 laboratories in the EQA. METHODS: MPXV virus-like particles with 2700, 900 and 300 copies/mL were distributed to 195 EQA laboratories. For extended analysis, triple-diluted samples from 9000 to 4.12 copies/mL were repeated 20 times using the assays employed by ≥ 5 laboratories. The diagnostic performance was assessed by analyzing EQA data and calculating the limits of detection (LODs). RESULTS: The performance was competent in 87.69% (171/195) of the participants and 87.94% (175/199) of the datasets. The positive percentage agreements (PPAs) were greater than 99% for samples at 2700 and 900 copies/mL, and 95.60% (761/796) for samples at 300 copies/mL. The calculated LODs for the two clades ranged from 228.44 to 924.31 copies/mL and were greater than the LODs specified by the respective kits. EasyDiagnosis had the lowest calculated LODs and showed superior performance in EQA, whereas BioGerm and Sansure, with higher calculated LODs, did not perform well in EQA. CONCLUSION: This study provides valuable information from the EQA data and evaluation of the diagnostic performance of MPXV detection assays. It also provided insights into reagent optimization and enabled prompt public health interventions for the outbreak.


Subject(s)
Real-Time Polymerase Chain Reaction , Sensitivity and Specificity , Humans , Real-Time Polymerase Chain Reaction/methods , China/epidemiology , Limit of Detection , Molecular Diagnostic Techniques/methods , Molecular Diagnostic Techniques/standards , Monkeypox virus/genetics , Monkeypox virus/isolation & purification
12.
Mod Pathol ; 36(4): 100084, 2023 04.
Article in English | MEDLINE | ID: mdl-36788080

ABSTRACT

The morphologic assessment of uterine leiomyosarcoma (LMS) may be challenging, and diagnostic immunohistochemical (IHC) analysis is currently lacking. We evaluated the genomic landscape of 167 uterine LMS by targeted next-generation sequencing (NGS) to identify common genomic alterations. IHC analyses corresponding to these genomic landmarks were applied to a test cohort of 16 uterine LMS, 6 smooth muscle tumors of uncertain malignant potential (STUMP), and 6 leiomyomas with NGS data and a validation cohort of 8 uterine LMS, 12 STUMP, 21 leiomyomas and leiomyoma variants, 7 low-grade endometrial stromal sarcomas, and 2 diagnostically challenging uterine smooth muscle tumors. IHC results were individually interpreted by 3 pathologists blinded to NGS data. Overall, 94% of LMS showed ≥1 genomic alteration involving TP53, RB1, ATRX, PTEN, CDKN2A, or MDM2, with 80% showing alterations in ≥2 of these genes. In the test cohort, an initial panel of p53, Rb, PTEN, and ATRX was applied, followed by a panel of DAXX, MTAP, and MDM2 in cases without abnormalities. Abnormal p53, Rb, PTEN, and ATRX IHC expression was seen in 75%, 88%, 44%, and 38% of LMS, respectively, in the test cohort. Two or more abnormal IHC results among these markers were seen in 81% of LMS. STUMPs demonstrated only 1 IHC abnormality involving these markers. No IHC abnormalities were seen in leiomyomas. In the validation cohort, abnormal p53, Rb, and PTEN IHC results were seen in LMS, whereas rare STUMP or leiomyomas with bizarre nuclei showed IHC abnormalities involving only 1 of the markers. Abnormalities in ≥2 markers were present in both diagnostically challenging smooth muscle tumors, confirming LMS. Concordance was excellent among pathologists in the interpretation of IHC (κ = 0.97) and between IHC and NGS results (κ = 0.941). Uterine LMS exhibit genomic landmark alterations for which IHC surrogates exist, and a diagnostic algorithm involving molecular-based IHC may aid in the evaluation of unusual uterine smooth muscle tumors.


Subject(s)
Algorithms , Immunohistochemistry , Leiomyosarcoma , Uterine Neoplasms , Female , Humans , Immunohistochemistry/methods , Leiomyosarcoma/diagnosis , Leiomyosarcoma/pathology , Molecular Diagnostic Techniques/standards , Reproducibility of Results , Uterine Neoplasms/diagnosis , Uterine Neoplasms/pathology
13.
Proc Natl Acad Sci U S A ; 117(37): 22727-22735, 2020 09 15.
Article in English | MEDLINE | ID: mdl-32868442

ABSTRACT

The COVID-19 pandemic provides an urgent example where a gap exists between availability of state-of-the-art diagnostics and current needs. As assay protocols and primer sequences become widely known, many laboratories perform diagnostic tests using methods such as RT-PCR or reverse transcription loop mediated isothermal amplification (RT-LAMP). Here, we report an RT-LAMP isothermal assay for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus and demonstrate the assay on clinical samples using a simple and accessible point-of-care (POC) instrument. We characterized the assay by dipping swabs into synthetic nasal fluid spiked with the virus, moving the swab to viral transport medium (VTM), and sampling a volume of the VTM to perform the RT-LAMP assay without an RNA extraction kit. The assay has a limit of detection (LOD) of 50 RNA copies per µL in the VTM solution within 30 min. We further demonstrate our assay by detecting SARS-CoV-2 viruses from 20 clinical samples. Finally, we demonstrate a portable and real-time POC device to detect SARS-CoV-2 from VTM samples using an additively manufactured three-dimensional cartridge and a smartphone-based reader. The POC system was tested using 10 clinical samples, and was able to detect SARS-CoV-2 from these clinical samples by distinguishing positive samples from negative samples after 30 min. The POC tests are in complete agreement with RT-PCR controls. This work demonstrates an alternative pathway for SARS-CoV-2 diagnostics that does not require conventional laboratory infrastructure, in settings where diagnosis is required at the point of sample collection.


Subject(s)
Coronavirus Infections/diagnosis , Molecular Diagnostic Techniques/methods , Pneumonia, Viral/diagnosis , Point-of-Care Testing/standards , Reverse Transcriptase Polymerase Chain Reaction/methods , Betacoronavirus/genetics , Betacoronavirus/pathogenicity , COVID-19 , Humans , Limit of Detection , Molecular Diagnostic Techniques/instrumentation , Molecular Diagnostic Techniques/standards , Nasal Mucosa/virology , Pandemics , Reproducibility of Results , Reverse Transcriptase Polymerase Chain Reaction/instrumentation , Reverse Transcriptase Polymerase Chain Reaction/standards , SARS-CoV-2 , Smartphone
14.
Br J Haematol ; 196(1): 63-69, 2022 01.
Article in English | MEDLINE | ID: mdl-34340260

ABSTRACT

Sickle cell disease (SCD) is a devastating and under-recognised global child health issue affecting over 300,000 infants annually, with the highest prevalence in India and sub-Saharan Africa. Most affected infants born in low- and middle-income countries (LMIC) lack access to SCD testing and die from complications in the first years of life without a formal diagnosis. The majority of deaths are preventable with early diagnosis and provision of inexpensive interventions. Despite global recognition of the urgent need, expansion of SCD newborn screening (NBS) programmes beyond the pilot stage has been obstructed by a dependence on an expensive and logistically challenging centralised laboratory testing model. Recently, several point-of-care tests (POCT) for SCD have been developed with promising field validation studies. Here, we summarise the state of POCT for SCD, review barriers and unanswered questions, and discuss optimal strategies for utilising POCT to address the growing global burden of SCD. There is an urgent need to prospectively evaluate the ability of POCT to reduce the morbidity and high early mortality of SCD. To impact a sustainable reduction to this end, it is essential to link a diagnosis with comprehensive SCD care, including wide and affordable access to affordable hydroxycarbamide therapy.


Subject(s)
Anemia, Sickle Cell/diagnosis , Anemia, Sickle Cell/epidemiology , Point-of-Care Testing , Capital Financing , Cost-Benefit Analysis , Early Diagnosis , Health Impact Assessment , Health Services Accessibility , Humans , Infant, Newborn , Molecular Diagnostic Techniques/economics , Molecular Diagnostic Techniques/instrumentation , Molecular Diagnostic Techniques/methods , Molecular Diagnostic Techniques/standards , Neonatal Screening , Point-of-Care Testing/economics , Point-of-Care Testing/standards , Prevalence , Reproducibility of Results , Sensitivity and Specificity
15.
Sex Transm Infect ; 98(2): 121-124, 2022 03.
Article in English | MEDLINE | ID: mdl-33632890

ABSTRACT

OBJECTIVES: European guidelines advise the use of dual nucleic acid amplification tests (NAAT) in order to minimise the inappropriate diagnosis of Neisseria gonorrhoeae (Ng) in urogenital samples from low prevalence areas and in extragenital specimens. In this cross-sectional study, we investigated the effect of confirmatory testing and confirmation policy on the Ng-positivity in a population visiting the sexual health clinic in Rotterdam, the Netherlands. METHODS: Apart from urogenital testing, extragenital (oropharyngeal/anorectal) testing was performed for men who have sex with men (MSM) and according to sexual exposure for women and heterosexual men. Ng detection using NAAT was performed using BD Viper and for confirmatory testing BD MAX. Sexual transmitted infection consultation data were merged with diagnostic data from August 2015 through May 2016. RESULTS: In women (n=4175), oral testing was performed in 84% and 22% were tested anally. In MSM (n=1828), these percentages were 97% and 96%, respectively. Heterosexual men (n=3089) were tested urogenitally. After confirmatory testing, oropharyngeal positivity rates decreased from 7.3% (95% CI 6.5 to 8.2) to 1.5% (95% CI 1.1 to 1.8) in women and from 13.9% (95% CI 12.3 to 15.5) to 5.4% (95% CI 4.3 to 6.4) in MSM. Anorectal positivity rates decreased from 2.6% (95% CI 1.6 to 3.7) to 1.8% (95% CI 0.9 to 2.6) in women and from 9.3% (95% CI 7.9 to 10.7) to 7.2% (95% CI 6.0 to 8.5) in MSM. Urogenital Ng-positivity rate ranged between 3.0% and 4.4% and after confirmation between 2.3% and 3.9%. When confirming oropharyngeal samples, Ng-positivity was 3.8% in women, 3.0% in heterosexual men and 12.5% in MSM. Additional confirmation of urogenital and anorectal samples led to 3.0% Ng positivity in women, 2.7% in heterosexual men and 11.4% in MSM. CONCLUSIONS: Confirmation of urogenital and anorectal samples reduced the Ng-positivity rates, especially for women. However, as there is no gold standard for the confirmation of Ng infection, the dilemma within public health settings is to choose between two evils: missing diagnoses or overtreatment. In view of the large decrease in oropharyngeal positivity, confirmation Ng-positivity in oropharyngeal samples remains essential to avoid unnecessary treatment.


Subject(s)
Gonorrhea/drug therapy , Gonorrhea/epidemiology , Heterosexuality/statistics & numerical data , Homosexuality, Male/statistics & numerical data , Molecular Diagnostic Techniques/methods , Neisseria gonorrhoeae/genetics , Sexual Health , Cross-Sectional Studies , Female , Gonorrhea/diagnosis , Humans , Male , Molecular Diagnostic Techniques/standards , Neisseria gonorrhoeae/isolation & purification , Netherlands/epidemiology , Prevalence , Retrospective Studies , Sexual Behavior
16.
J Clin Lab Anal ; 36(2): e24242, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35019184

ABSTRACT

BACKGROUND: Currently, SARS-CoV-2 RNA detection using real-time reverse-transcription PCR (rRT-PCR) is the standard diagnostic test for COVID-19 infection. Various rRT-PCR assays are currently used worldwide, targeting different genes of the SARS-CoV-2. Here, we compared the analytical sensitivity and clinical performance (sensitivity and specificity) of Allplex SARS-CoV-2/FluA/FluB/RSV assay (Seegene), Standard M nCoV real-time detection kit (SD Biosensor), and U-TOP COVID-19 detection kit (Seasun Biomaterials) for SARS-CoV-2 detection. METHODS: Two hundred and forty-nine nasopharyngeal swab samples were evaluated to compare the clinical performance of the rRT-PCR assays. For the analytical performance evaluation, two RNA controls with known viral loads-SARS-CoV-2 RNA control and SARS-COV-2 B.1.351 RNA control-were used to investigate the potential impact of SARS-CoV-2 variants, particularly the B.1.351 lineage. RESULTS: Limits of detection ranged from 650 to 1300 copies/ml for rRT-PCR assays, and the mean differences in cycle threshold (Ct ) values of the two RNA controls were within 1.0 for each target in the rRT-PCR assays (0.05-0.73), without any prominent Ct value shift or dropouts in the SARS-COV-2 B.1.351 RNA control. Using the consensus criterion as the reference standard, 89 samples were positive, whereas 160 were negative. The overall clinical performance of rRT-PCR assays was comparable (sensitivity 98.88%-100%; specificity 99.38%-100%), whereas the sensitivities of each target gene were more variable. CONCLUSIONS: The three rRT-PCR assays showed comparable analytical sensitivity and clinical performance. The analytical and clinical sensitivities of each target gene were influenced more by the primer and probe design than the target gene itself.


Subject(s)
COVID-19/diagnosis , Molecular Diagnostic Techniques , Reagent Kits, Diagnostic/virology , Real-Time Polymerase Chain Reaction , SARS-CoV-2/genetics , Adolescent , Adult , Aged , Aged, 80 and over , Child , Female , Humans , Male , Middle Aged , Molecular Diagnostic Techniques/methods , Molecular Diagnostic Techniques/standards , Nasopharynx/virology , Real-Time Polymerase Chain Reaction/methods , Real-Time Polymerase Chain Reaction/standards , SARS-CoV-2/isolation & purification , Sensitivity and Specificity , Viral Load , Young Adult
17.
J Clin Lab Anal ; 36(2): e24226, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34997789

ABSTRACT

INTRODUCTION: RT-PCR is widely used as a diagnostic test for the detection of SARS-CoV-2. In this study, we aim to describe the clinical utility of serial PCR testing in the final detection of COVID-19. METHOD: We collected multiple nasopharyngeal swab samples from patients who had negative RT-PCR test on the first day after hospitalization. RT-PCR tests were performed on the second day for all patients with initial negative result. For the patients with secondary negative results on day 2, tertiary RT-PCR tests were performed on day 3 after hospitalization. RESULT: Among 68 patients with initial negative test results, at the end of follow-up, the mortality number was 20 (29.4%). About 33.8% of patients had subsequent positive PCR test results for the second time and 17.4% of the patients who performed third PCR test had positive result. CONCLUSION: Based on this study, serial RT-PCR testing is unlikely to yield additional information.


Subject(s)
COVID-19/diagnosis , Molecular Diagnostic Techniques , Real-Time Polymerase Chain Reaction , SARS-CoV-2/genetics , Aged , Aged, 80 and over , False Negative Reactions , Female , Humans , Male , Middle Aged , Molecular Diagnostic Techniques/methods , Molecular Diagnostic Techniques/standards , Molecular Diagnostic Techniques/statistics & numerical data , Real-Time Polymerase Chain Reaction/methods , Real-Time Polymerase Chain Reaction/standards , Real-Time Polymerase Chain Reaction/statistics & numerical data , SARS-CoV-2/isolation & purification
18.
Br J Haematol ; 193(2): 231-244, 2021 04.
Article in English | MEDLINE | ID: mdl-33058194

ABSTRACT

In recent years there have been major advances in the use of molecular diagnostic and monitoring techniques for patients with acute myeloid leukaemia (AML). Coupled with the simultaneous explosion of new therapeutic agents, this has sown the seeds for significant improvements to treatment algorithms. Here we show, using a selection of real-life examples, how molecular monitoring can be used to refine clinical decision-making and to personalise treatment in patients with AML with nucleophosmin (NPM1) mutations, core binding factor translocations and other fusion genes. For each case we review the established evidence base and provide practical recommendations where evidence is lacking or conflicting. Finally, we review important technical considerations that clinicians should be aware of in order to safely exploit these technologies as they undergo widespread implementation.


Subject(s)
Leukemia, Myeloid, Acute/diagnosis , Leukemia, Myeloid, Acute/genetics , Molecular Diagnostic Techniques/methods , Neoplasm, Residual/genetics , Adolescent , Adult , Algorithms , Allografts/transplantation , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Clinical Decision-Making/methods , Core Binding Factors/genetics , Female , Gene Fusion/genetics , Humans , Karyotype , Leukemia, Myeloid, Acute/therapy , Male , Middle Aged , Molecular Diagnostic Techniques/standards , Mutation , Nuclear Proteins/genetics , Nucleophosmin , Outcome Assessment, Health Care , Precision Medicine/methods , Translocation, Genetic/genetics , Unrelated Donors
19.
BMC Microbiol ; 21(1): 236, 2021 08 26.
Article in English | MEDLINE | ID: mdl-34445973

ABSTRACT

BACKGROUND: The ePlex® and QIAstat-Dx® respiratory pathogen panels detect multiple respiratory pathogens, mainly viruses but also Legionella pneumophila, Mycoplasma pneumoniae and Bordetella pertussis. The assays have been marketed for use in nasopharyngeal swab specimens. For diagnosing bacterial pneumonia, lower respiratory tract (LRT) specimens are indicated. Aim of this study was to evaluate the performance of these syndromic panels for these three bacterial targets in samples from the LRT. Fifty-six specimens were collected from our repositories, five negative samples and fifty-one samples which had been previously tested positive with the routine diagnostic real-time PCR assays for Legionella spp. (N = 20), Bordetella spp. (N = 16) or M. pneumoniae (N = 15). RESULTS: The QIAstat-Dx Respiratory Panel V2 (RP) assay detected all of the L. pneumophila and B. pertussis positive samples but only 11/15 (73.3 %) of the M. pneumoniae targets. The ePlex Respiratory Pathogen Panel (RPP) assay detected 10/14 (71.4 %) of the L. pneumophila targets, 8/12 (66.7 %) of the B. pertussis positive samples and 13/15 (86.7 %) of the M. pneumoniae targets. CONCLUSIONS: No false-positive results were reported for all three bacterial pathogens by both assays. The clinical performance of both assays depended highly on the bacterial load in the sample and the type of specimen under investigation.


Subject(s)
Bacteria/genetics , Molecular Diagnostic Techniques/standards , Reagent Kits, Diagnostic/standards , Respiratory Tract Infections/diagnosis , Respiratory Tract Infections/microbiology , Bacteria/classification , Bacteria/isolation & purification , Bacteria/pathogenicity , Bacterial Load/methods , Bacterial Load/standards , Female , Humans , Male , Molecular Diagnostic Techniques/methods , Multiplex Polymerase Chain Reaction/instrumentation , Multiplex Polymerase Chain Reaction/standards , Pneumonia, Bacterial/diagnosis , Pneumonia, Bacterial/microbiology
20.
J Med Virol ; 93(6): 3999-4003, 2021 06.
Article in English | MEDLINE | ID: mdl-32761911

ABSTRACT

BACKGROUND: Monitoring viral load (VL) is an essential part of the management of patients chronically infected with hepatitis B virus (HBV). The commercial HBV VL assays currently available are generally performed on high-throughput platforms for batch wise testing of plasma samples, with relatively long turn-around-times. Rapid VL testing could provide immediate input to clinical decision making. METHODS: One hundred two stored plasma samples from 102 patients who were previously tested for HBV VL by the Cobas Ampliprep/Taqman or Cobas 4800 (Roche, Pleasanton, CA), were analyzed by the recently introduced Cepheid Xpert HBV Viral Load Assay. Thirty-one of the 102 samples were negative for HBV DNA and 71 out of 102 samples had a detectable VL. HBV DNA loads ranged from <20 to 5E8 IU/mL. HBV genotypes (A, B, C, D, E, and G) were known for 52 of the VL positive samples. Correlation of VL results between both assays was determined by the Pearson correlation coefficient (r2 ). The level of concordance was assessed using the Bland-Altman analysis. RESULTS: HBV VLs correlated well between both assays, across all genotypes (Pearson correlation coefficient r2 = 0.987). Six samples exceeded a 0.5 log difference between assays. Bland-Altman analysis demonstrated a mean of the difference of -0.107 log and a standard deviation of 0.271 log. CONCLUSION: High correlation was observed between the Roche Cobas HBV Viral Load tests and the Xpert HBV Viral Load Assay, thus enabling rapid, random access, and accurate HBV VL assessment.


Subject(s)
DNA, Viral/blood , Hepatitis B virus/genetics , Hepatitis B/diagnosis , Molecular Diagnostic Techniques/methods , Viral Load/instrumentation , Viral Load/methods , Genotype , Hepatitis B/blood , Hepatitis B/virology , Hepatitis B virus/classification , Hepatitis B virus/isolation & purification , Humans , Limit of Detection , Molecular Diagnostic Techniques/standards , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL