1.
J Card Surg ; 35(6): 1220-1227, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32353903

RESUMEN

BACKGROUND AND AIM OF THE STUDY: Transfusion of blood products after coronary artery bypass grafting (CABG) is associated with increased morbidity and mortality. We evaluated the perioperative use of blood products in patients undergoing CABG in our institution over the past two decades. METHODS: The study included 18 992 patients who underwent isolated CABG at our hospital between 1998 and 2017. Baseline characteristics of patients and the number of perioperative transfusions during their hospital stay (including red blood cells [RBCs], platelets, and fresh frozen plasma [FFP]) were assessed. Logistic regression models were used to identify risk factors for perioperative transfusion. RESULTS: The rates of perioperative RBC transfusion decreased for all patients undergoing isolated CABG (52.1% in 1998 vs 18.6% in 2017) in our institution. The mean number of transfused RBC units was significantly higher in women than in men (1.57 ± 2.2 vs 0.68 ± 1.84; P < .005); this difference remained significant over the years. After adjusting the results for other risk factors, female sex was a significant independent risk factor for perioperative RBC transfusion. The platelet transfusion rate increased over the past two decades (1.4% in 1998 vs 9.7% in 2017). The number of FFP transfusions remained unchanged. CONCLUSIONS: Over the past two decades, we observed a decrease in the incidence of perioperative RBC transfusions in patients undergoing isolated CABG, whereas platelet transfusions increased. Female sex was an independent predictor of perioperative RBC transfusion.


Asunto(s)
Puente de Arteria Coronaria/métodos , Puente de Arteria Coronaria/tendencias , Transfusión de Eritrocitos/estadística & datos numéricos , Atención Perioperativa/efectos adversos , Atención Perioperativa/métodos , Atención Perioperativa/estadística & datos numéricos , Transfusión de Plaquetas/estadística & datos numéricos , Anciano , Transfusión de Eritrocitos/efectos adversos , Transfusión de Eritrocitos/tendencias , Femenino , Humanos , Masculino , Persona de Mediana Edad , Atención Perioperativa/tendencias , Transfusión de Plaquetas/efectos adversos , Transfusión de Plaquetas/tendencias , Factores de Riesgo , Factores Sexuales
2.
Cardiol Young ; 30(9): 1231-1237, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32698928

RESUMEN

BACKGROUND: Catheter ablation is an important therapeutic option for atrial tachycardias in patients with CHD. As a result of extensive scarring and surgical repair, multiple intra-atrial re-entrant tachycardia circuits develop and serve as a substrate for arrhythmias. The best ablation approach for patients with multiple intra-atrial re-entrant tachycardias has not been investigated. Here, we compared substrate-based ablation using extensive scar modification to conventional ablation. METHODS: The present study included patients with surgically corrected CHD that underwent intra-atrial re-entrant tachycardia ablation. Extensive scar modification was defined as substrate ablation based on a dense voltage map, aimed to eliminate all potentials in the scar region. The control group had activation mapping-based ablation. A clinical composite endpoint was assessed. Points were given for type, number, and treatment of intra-atrial re-entrant tachycardia recurrence. RESULTS: In 40 patients, 63 (extensive scar modification 13) procedures were performed. Acute procedural success was achieved in 78%. Procedural duration was similar in both groups. Forty-nine percent had a recurrence within 1 year. During a 5-year follow-up (2.5-7.5 years), 46% required repeat catheter ablation. Compared to baseline, clinical composite endpoint significantly decreased by 46% after 12 months (p = 0.001). Acute procedural success, procedural parameters, recurrence and repeat ablation were similar between extensive scar modification and activation mapping-based ablation. CONCLUSION: Catheter ablation using extensive scar modification for intra-atrial re-entrant tachycardias occurring after surgically corrected CHD illustrated similar short- and long-term outcomes and procedural efficiency compared to catheter ablation using activation mapping-based ablation. The choice of ablation approach for multiple intra-atrial re-entrant tachycardia should remain at the discretion of the operator.


Asunto(s)
Ablación por Catéter , Cardiopatías Congénitas , Taquicardia Supraventricular , Cicatriz/etiología , Cicatriz/cirugía , Cardiopatías Congénitas/cirugía , Humanos , Taquicardia/cirugía , Taquicardia Supraventricular/cirugía , Resultado del Tratamiento
4.
Europace ; 20(suppl_2): ii28-ii32, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-29722855

RESUMEN

Aims: Remote magnetic navigation (RMN) is an alternative to manual catheter control (MCC) radiofrequency ablation of right ventricular outflow tract (RVOT) arrhythmias. The data to support RMN approach is limited. We aimed to investigate the clinical and procedural outcomes in a cohort of patients undergoing RVOT premature ventricular complex/ventricular tachycardia (PVCs/VT) ablation procedures using RMN vs. MCC. Methods and results: Data was collected from two centres. Eighty-nine consecutive RVOT PVCs/VT ablation procedures were performed in 75 patients; RMN: 42 procedures and MCC: 47 procedures. CARTOXPTM or CARTO3 (Biosense Webster) was used for endocardial mapping in 19/42 (45%) in RMN group and 28/47 (60%) in MCC group; EnSiteTM NavXTM (St. Jude Medical) was used in the rest of the cohort. Stereotaxis platform (Stereotaxis Inc., St. Louis, MO, USA) was used for RMN approach. Procedural time was 113 ± 53 min in the RMN group and 115 ± 69 min in MCC (P = 0.90). Total fluoroscopic time was 10.9 ± 5.8 vs. 20.5 ± 13.8 (P < 0.05) and total ablation energy application time 7.0 ± 4.7 vs 11.9 ± 16 (P = 0.67) accordingly. There were two complications in RMN group and five in MCC (P = 0.43). Acute procedural success rate was 80% in RMN vs. 74% in MCC group (P = 0.46). After a median follow-up of 25 months (interquartile range 13-34), the success rate remained 55% in the RMN group and 53% in MCC (P = 0.96). Conclusion: Right ventricular outflow tract arrhythmia ablations were performed using half of fluoroscopic times with Stereotaxis platform RMN compared to manual approach. Acute and chronic success rates as well as complication rates were not significantly different.


Asunto(s)
Cateterismo Cardíaco/métodos , Ablación por Catéter/métodos , Magnetismo/métodos , Tecnología de Sensores Remotos/métodos , Cirugía Asistida por Computador/métodos , Taquicardia Ventricular/cirugía , Complejos Prematuros Ventriculares/cirugía , Potenciales de Acción , Adulto , Anciano , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Femenino , Fluoroscopía , Frecuencia Cardíaca , Humanos , Magnetismo/instrumentación , Imanes , Masculino , Persona de Mediana Edad , Tempo Operativo , Complicaciones Posoperatorias/etiología , Exposición a la Radiación , Tecnología de Sensores Remotos/efectos adversos , Tecnología de Sensores Remotos/instrumentación , Estudios Retrospectivos , Factores de Riesgo , Cirugía Asistida por Computador/efectos adversos , Cirugía Asistida por Computador/instrumentación , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/fisiopatología
6.
Artículo en Inglés | MEDLINE | ID: mdl-27568851

RESUMEN

BACKGROUND: Noncompaction cardiomyopathy (NCCM) is considered to be the result of an arrest in the normal myocardial embryogenesis. The histological, developmental, and electrophysiological explanation of ventricular arrhythmias in NCCM is still unknown. The aim of this study was to determine the origin of premature ventricular contractions (PVCs) in NCCM and to identify any predominant arrhythmic foci. METHODS: Retrospective data from our NCCM registry including 101 patients were analyzed. A total number of 2069 electrocardiograms (ECGs) were studied to determine the origin of PVCs. Echocardiographic data were analyzed in patients with PVCs in all 12 leads. Segments affected by noncompaction (NC) were compared with the origin of PVCs. RESULTS: PVCs were documented in 250 ECGs from 55 (54%) patients. Thirty-five ECGs recorded PVCs on all 12 leads and the origin of 20 types of PVCs could be determined. Ninety-five percent of PVCs did not originate from left ventricular NC myocardial areas and two PVCs (10%) had a true myocardial origin. All other PVCs originated from structures such as the outflow tracts (8/20), the fascicles (7/20), especially the posteromedial fascicle (6/20), and the mitral and tricuspid annulus (3/20). CONCLUSIONS: Our data suggest that PVCs in NCCM mainly originate from the conduction system and related myocardium.


Asunto(s)
Síndrome de Brugada/fisiopatología , Cardiomiopatías/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Complejos Prematuros Ventriculares/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Síndrome de Brugada/complicaciones , Trastorno del Sistema de Conducción Cardíaco , Cardiomiopatías/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Complejos Prematuros Ventriculares/complicaciones , Adulto Joven
7.
J Cardiovasc Electrophysiol ; 26(11): 1224-1229, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26200478

RESUMEN

BACKGROUND: Poor catheter-to-myocardial contact can lead to ineffective ablation lesions and suboptimal outcome. Contact force (CF) sensing catheters in ventricular tachyarrhythmia (VT) ablations have not been studied for their long-term efficacy. PURPOSE: The aim of this study was to compare CF ablation to manual ablation (MAN) and remote magnetic navigation (RMN) ablation for safety and efficacy in acute and long-term outcome. METHODS: A total of 239 consecutive patients who underwent VT ablation with the use of MAN, CF, or RMN catheters were included in this single-center cohort study from January 2007 until March 2014. The primary endpoints were procedural success, acute major complications, and VT recurrences at follow-up. The median follow-up period was 25 months. RESULTS: Acute success was achieved in 182 out of 239 procedures (76%). Acute success in manual ablation, CF ablation and RMN ablation was 71%, 71%, and 86%, respectively (P = 0.03). Major complications occurred in 3.3% and there were less major complications (P = 0.04) in the RMN group. After an initial successful procedure, 66 of 182 patients (36%) had a recurrence during follow-up. This was not significantly different between groups. Using an intention-to-treat analysis, 124 patients (52%) had a recurrence. The recurrence rate was lowest in the RMN group. CONCLUSION: The use of CF sensing catheters did not improve procedural outcome or safety profile in comparison to non-CF sensing ablation in this observational study of ventricular arrhythmia ablations.

8.
Europace ; 16(6): 893-8, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24280196

RESUMEN

AIMS: Atrial tachycardias (ATs) frequently develop in patients with congenital heart defects (CHDs). This study aimed to evaluate the effects of extensive atrial scar formation on the total atrial activation time (TAAT) and its relation to the tachycardia cycle length (CL) to classify AT. METHODS AND RESULTS: Seventy-one patients were included and divided into two groups: patients without CHD (Group I, 35 patients) and with CHD (Group II, 36 patients). All patients underwent CARTO electroanatomical activation mapping. Two subgroups were created: centrifugal (CAT) or macroreentrant AT (MRAT). Total atrial activation time, CL, and mean bipolar signal amplitude (BiSA) were analysed. In Group I, 18 patients (51.4%) had CAT and 17 (48.6%) MRAT. The mean BiSA for Group I was 1.30 ± 0.32 mV. Total atrial activation time/CL ratios were different between CAT and MRAT (28.4 ± 16.9 vs. 66.6 ± 14.3%, P < 0.001). In Group II, 18 patients (50%) had CAT and 18 patients (50%) MRAT. The mean BiSA was 0.94 ± 0.50 mV and was not different for CAT and MRAT subgroups (1.04 ± 0.64 vs. 0.85 ± 0.29, P = 0.243). Total atrial activation time/CL ratios were comparable between CAT and MRAT patients (69.0 ± 40.4 vs. 83.6 ± 8.3%, P = 0.243). A significant lower BiSA was found for CAT with TAAT/CL ratios above 40% (0.62 ± 0.11 vs. 1.90 ± 0.18 mV, P < 0.001). A strong negative correlation was identified between the BiSA and the TAAT/CL ratio in patients with CAT in Group II (-0.742; P < 0.001). CONCLUSION: Low mean BiSA values in CHD patients are associated with altered impulse propagation, making TAAT- and CL-based diagnostic tools inaccurate. Further diagnostic tests are needed to determine the correct mechanism of ATs.


Asunto(s)
Anomalías Múltiples/diagnóstico , Mapeo del Potencial de Superficie Corporal/métodos , Cicatriz/diagnóstico , Cardiopatías Congénitas/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia Atrial Ectópica/diagnóstico , Adulto , Cicatriz/complicaciones , Diagnóstico Diferencial , Femenino , Atrios Cardíacos , Cardiopatías Congénitas/complicaciones , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Taquicardia por Reentrada en el Nodo Atrioventricular/complicaciones , Taquicardia Atrial Ectópica/complicaciones
9.
Pacing Clin Electrophysiol ; 37(7): 864-73, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24576009

RESUMEN

BACKGROUND: After catheter ablation there is often a discrepancy between acute and chronic success rates. We aimed to evaluate major determinants for lesion quality and understand different manifestations of lesion structures. METHODS: In a canine thigh muscle model radiofrequency (RF) current was delivered for 60 seconds at 30 W (n = 39) or 50 W (n = 18) with 15-g contact force. A second-generation 12-hole gold open irrigation catheter (SGIT) and a first-generation six-hole platinum-iridium catheter (FGIT; Biotronik, Berlin, Germany) were used. Electrode and tissue temperatures (at the surface and 3.5-mm and 7-mm depth) were recorded and lesion dimensions were measured. Lesions with steam pops were excluded. Histological examination was performed to evaluate homogeneity of the lesions. Inhomogeneity was defined as a visual multiband lesion pattern indicating different histological characteristics. RESULTS: In total 57 lesions were created. Seventeen lesions were excluded (steam pops) and 40 lesions were analyzed. A total number of 11 homogeneous and 29 inhomogeneous lesions were identified. Using the SGIT catheter 16.7% of the lesions was homogeneous and 83.3% inhomogeneous; for FGIT it was 43.8% and 56.2% (P = 0.065), respectively. Homogeneous lesions had lower volumes as compared to inhomogeneous lesions (514.0 ± 198.8 vs 914.8 ± 399.1 mm, P = 0.003). Multiple logistic regression analysis indicated that the SGIT catheter is a significant predictor for inhomogeneous lesions (odds ratio 6.5, 95% confidence interval 1.1-38.8; P = 0.040) independent from power setting and flow rate. CONCLUSIONS: The development of inhomogeneous lesions after acute RF ablation is associated with higher lesion volumes and the use of the second-generation irrigation gold-tip catheter.


Asunto(s)
Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Animales , Catéteres , Perros , Diseño de Equipo , Músculo Esquelético/patología , Músculo Esquelético/cirugía , Irrigación Terapéutica
10.
Int J Cardiol ; 409: 132175, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38754586

RESUMEN

OBJECTIVE: This study compared perioperative outcomes after off-pump revascularization through a thoracoscopic-assisted (non-robotic) minimally invasive approach (Endo-CAB) or sternotomy approach (OPCAB) for patients with single vessel left anterior descending (LAD) disease. METHODS: In this retrospective, propensity matched cohort study, 266 consecutive patients were included in the Endo-CAB group (n = 136) and OPCAB group (n = 130). After propensity score matching 116 Endo-CAB and 116 OPCAB patients were compared. 'Textbook outcome' was defined as the absence of 30-day mortality, re-exploration for bleeding, postoperative ischemia, cardiac tamponade, cerebrovascular events, wound infection, new-onset arrhythmias, pneumonia, placement of chest drains and prolonged hospital stay (> 7 days). Multivariable regression analysis was performed to identify independent predictors for textbook outcome. RESULTS: Textbook outcome occurred significantly more frequent in the Endo-CAB group compared to the OPCAB group (81.9% vs. 59.5%, p < 0.001). Patients undergoing Endo-CAB surgery had shorter hospital admission (3.0 [3.0-4.0] vs. 5.0 [4.0-6.0] days, p < 0.001), less blood loss (225 [150-355] vs. 450 [350-600] mL, p < 0.001). Other perioperative outcomes were comparable for both groups. Regression analysis demonstrated that Endo-CAB approach was an independent positive predictor for textbook outcome (OR 3.02, 95% CI 1.61-5.66, p < 0.001). CONCLUSIONS: Our study suggests that patients undergoing Endo-CAB surgery have improved perioperative outcome resulting in higher rates of textbook outcome for the treatment of single vessel CAD. This technique could be widely available since routine thoracoscopic instruments are used.


Asunto(s)
Puente de Arteria Coronaria Off-Pump , Enfermedad de la Arteria Coronaria , Procedimientos Quirúrgicos Mínimamente Invasivos , Puntaje de Propensión , Toracoscopía , Humanos , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Toracoscopía/métodos , Puente de Arteria Coronaria Off-Pump/métodos , Enfermedad de la Arteria Coronaria/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Estudios de Cohortes , Resultado del Tratamiento , Complicaciones Posoperatorias/epidemiología
11.
Ann Cardiothorac Surg ; 13(1): 91-98, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38380139

RESUMEN

Concomitant atrial fibrillation (AF) ablation in cardiac surgery effectively restores sinus rhythm and may reduce morbidity and mortality. Cardiac surgery has witnessed the transition from the historical Cox Maze procedure to more modern and less invasive approaches for concomitant AF treatment. As minimally invasive cardiac surgery gains traction, ablation methods and careful patient selection become crucial to optimize results. Emerging techniques, including bipolar epicardial radiofrequency and endo/epicardial cryoablation, are central to these advances, targeting specific arrhythmogenic areas within the atria. While pulmonary vein isolation (PVI) is essential, it may be insufficient for patients with persistent or longstanding persistent AF. In such cases, left atrial posterior wall isolation has proven beneficial. Furthermore, recent studies emphasize the significance of left atrial appendage occlusion in concurrent AF treatments, highlighting its role in stroke risk reduction. Notably, the left atrium remains the focal point for concomitant AF surgery over the right, primarily due to concerns like high pacemaker implantation rates and complexities of right atrial ablation sets. Although guidelines support its widespread use, concomitant AF ablation outcomes vary based on patient selection, surgeon's expertise, and clinical context and thus the Heart Team's input is crucial for individualized decisions. In the upcoming sections, we present our patient selection and a visual guide to our techniques for concomitant AF surgery in minimally invasive mitral valve, coronary artery bypass and aortic valve surgery.

12.
Europace ; 15(10): 1426-31, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23493412

RESUMEN

AIMS: After initial catheter ablation, repeat procedures could be necessary. This study evaluates the efficacy of the magnetic navigation system (MNS) in repeat catheter ablation as compared with manual conventional techniques (MANs). METHODS AND RESULTS: The results of 163 repeat ablation procedures were analysed. Ablations were performed either using MNS (n = 84) or conventional manual ablation (n = 79). Procedures were divided into four groups based on the technique used during the initial and repeat ablation procedure: MAN-MAN (n = 66), MAN-MNS (n = 31), MNS-MNS (n = 53), and MNS-MAN (n = 13). Three subgroups were analysed: supraventricular tachycardias (SVTs, n = 68), atrial fibrillation (AF, n = 67), and ventricular tachycardias (VT, n = 28). Recurrences were assessed during 19 ± 11 months follow-up. Overall, repeat procedures using MNS were successful in 89.0% as compared with 96.2% in the MAN group (P = ns). The overall recurrence rate was significantly lower using MNS (25.0 vs. 41.4%, P = 0.045). Acute success and recurrence rates for the MAN-MAN, MAN-MNS, MNS-MNS, and MNS-MAN groups were comparable. For the SVT subgroup a higher acute success rate was achieved using MAN (87.9 vs. 100.0%, P = 0.049). The use of MNS for SVT is associated with longer procedure times (205 ± 82 vs. 172 ± 69 min, P = 0.040). For AF procedure and fluoroscopy times were longer (257 ± 72 vs. 185 ± 64, P = 0.001; 59.5 ± 19.3 vs. 41.1 ± 18.3 min, P < 0.001). Less fluoroscopy was used for MNS-guided VT procedures (22.8 ± 14.7 vs. 41.2 ± 10.9, P = 0.011). CONCLUSION: Our data suggest that overall MNS is comparable with MAN in acute success after repeat catheter ablation. However, MNS is related to fewer recurrences as compared with MAN.


Asunto(s)
Arritmias Cardíacas/cirugía , Ablación por Catéter/métodos , Magnetismo , Cirugía Asistida por Computador , Adulto , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía Intervencional , Recurrencia , Sistema de Registros , Reoperación , Cirugía Asistida por Computador/efectos adversos , Taquicardia Supraventricular/cirugía , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
13.
Pacing Clin Electrophysiol ; 36(11): 1373-81, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23875670

RESUMEN

BACKGROUND: High irrigation rates during radiofrequency (RF) ablation may cause fluid overload and limit lesion size. This in vivo animal study assessed the safety and efficacy of RF ablation at low irrigation rates using a novel 12-hole gold catheter. METHODS: A total of 103 lesions, created on the thigh of five mongrel dogs, were analyzed. Lesions were created using a 12-hole irrigated gold-tip (Au) and a six-hole irrigated platinum-iridium (PtIr) catheter (both 7F/3.5-mm electrode; BIOTRONIK SE & CO, KG, Berlin, Germany) in parallel and perpendicular orientation. RF current was delivered for 60 seconds at 30 W using 8 mL/min and 15 mL/min irrigation. Electrode temperature, steam pops, lesion dimensions, and coagulum formation were recorded. RESULTS: Electrode temperatures were lower for Au compared to PtIr in parallel (8 mL/min: 38.1 ± 1.7°C vs 48.0 ± 4.8°C, P < 0.0001; 15 mL/min: 36.0 ± 1.5°C vs 46.9 ± 5.4°C, P < 0.0001) and perpendicular position (15 mL/min: 35.5 ± 1.2°C vs 38.4 ± 2.5°C, P = 0.003). The number of steam pops between Au and PtIr was comparable for parallel (8 mL/min: 14% vs 27%, P = 0.65; 15 mL/min: 14% vs 43%, P = 0.21) and perpendicular orientation (8 mL/min: 25% vs 17%, P = 1.00; 15 mL/min: 18% vs 0%, P = 0.48). Au created larger volumes than PtIr at 8 mL/min irrigation (861 ± 251 mm(3) vs 504 ± 212 mm(3) , P = 0.004); however, for 15 mL/min, volumes were comparable (624 ± 269 mm(3) vs 768 ± 466 mm(3) , P = 0.46). No coagulum formation was observed for any of the catheters on the surface and catheter tip. CONCLUSION: RF ablation at low flow rate using a novel 12-hole irrigation Au catheter is safe and results in larger lesions than with a PtIr electrode.


Asunto(s)
Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Músculo Esquelético/citología , Músculo Esquelético/cirugía , Irrigación Terapéutica/instrumentación , Irrigación Terapéutica/métodos , Animales , Perros , Diseño de Equipo , Análisis de Falla de Equipo , Oro , Reología/instrumentación , Reología/métodos
14.
Acta Cardiol ; 68(6): 559-67, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24579433

RESUMEN

OBJECTIVE: Ablation of atrioventricular nodal re-entrant tachycardia (AVNRT) is a highly effective procedure both with radiofrequency (RF) and cryoenergy (CE). Conventionally, it requires several diagnostic catheters and hospital admission. This study assessed the safety and efficacy of a highly simplified approach using the magnetic navigation system (MNS) compared to CE and manual RF ablation (MAN). METHODS AND RESULTS: In the MNS group a single magnetic-guided quadripolar catheter was inserted through the internal jugular vein to perform ablation. In the CE group cryomapping preceded ablation and for MAN procedures conventional ablation was performed. The following parameters were analysed: success- and recurrence rate, procedure-, fluoroscopy- and total application time. In total 69 eligible patients were treated with MNS (n = 26), CE (n = 25) and MAN (n = 16). The success rates were 100%, 100% and 94%, respectively (p = ns). The mean procedural time was 83 +/- 25 min for MNS, 117 +/- 47 min for CE and 117 +/- 55 min for MAN (P < 0.01). Total radiation time was significantly lower for MNS [0.0 min (IQR 0.0-0.0)] compared to CE [15.1 min (IQR 9.1-23.8), P < 0.001] and MAN [17.5 min (IQR 7.0-31.3), P < 0.001]. The total application time was comparable for both RF groups: 357 +/- 315 s (MNS) vs 204 +/- 177 s (MAN) (P = 0.14). No major adverse events occurred. After 3 months follow-up similar PR intervals were recorded for all patients. During a follow-up of 26 +/- 5 months recurrence rates were 3.8%, 4.0% and 6.3%, respectively, for each group. CONCLUSIONS: The MNS-guided single-catheter approach is a feasible and safe technique for the treatment of patients with typical AVNRT.


Asunto(s)
Ablación por Catéter/instrumentación , Magnetismo/instrumentación , Imanes , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Electrocardiografía , Estudios de Factibilidad , Femenino , Fluoroscopía/métodos , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
15.
Artículo en Inglés | MEDLINE | ID: mdl-37965985

RESUMEN

Minimally invasive coronary surgery offers benefits to the patient. Harvesting the internal mammary artery remains a challenging part of this procedure. We describe our technique for thoracoscopic harvesting of the left and right mammary arteries using routine endoscopic instruments. This is a non-robotic technique that might facilitate a more widespread growth of minimally invasive coronary surgery.


Asunto(s)
Arterias Mamarias , Humanos , Arterias Mamarias/trasplante , Endoscopía , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Toracotomía/métodos
16.
Innovations (Phila) ; 18(3): 262-265, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37294049

RESUMEN

OBJECTIVE: Harvest of the left internal mammary artery (LIMA) is a technically demanding element of minimally invasive coronary surgery. We aimed to evaluate the learning curve of thoracoscopic, nonrobotic LIMA harvest during endoscopic coronary artery bypass (Endo-CAB) surgery. METHODS: Eighty patients undergoing Endo-CAB surgery were included. LIMA harvest was performed using commonly available video-assisted thoracoscopic instruments. Time from incision until heparin administration was defined as total LIMA harvest time (this includes opening of the pericardium and identification of coronary targets). LIMA harvest times (N = 80) and total procedure times for single-vessel grafting (n = 51) were analyzed. RESULTS: The mean LIMA harvest time was 58 ± 19 min, ranging from 15 to 113 min. The mean procedure time was 150 ± 39 min. Significant reductions in both LIMA harvest and total Endo-CAB procedure times were observed with increasing experience (logarithmic regression Y = 109 - 14.9*log(x), P < 0.001; Y = 227 - 24.4*log(x), P < 0.001, respectively). No damage to the LIMA occurred during thoracoscopic harvesting. CONCLUSIONS: Total thoracoscopic (nonrobotic) LIMA harvest is an efficient technique with a steep learning curve using routine instruments. More patients might benefit from minimally invasive coronary surgery using thoracoscopic LIMA harvest techniques.


Asunto(s)
Arterias Mamarias , Humanos , Arterias Mamarias/cirugía , Curva de Aprendizaje , Puente de Arteria Coronaria/métodos , Toracoscopía , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Resultado del Tratamiento
17.
J Cardiovasc Electrophysiol ; 23(9): 948-54, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22554147

RESUMEN

UNLABELLED: Remote Magnetic Navigation for VT Ablation. BACKGROUND: This study aimed to compare acute and late outcomes of VT ablation using the magnetic navigation system (MNS) to manual techniques (MAN) in patients with (SHD) and without (NSHD) structural heart disease. METHODS: Ablation data of 113 consecutive patients (43 SHD, 70 NSHD) with ventricular tachycardia treated with catheter ablation at our center were analyzed. Success rate, complications, procedure, fluoroscopy, and ablation times, and recurrence rates were systematically recorded for all patients. RESULTS: A total of 72 patients were included in the MNS group and 41 patients were included in the MAN group. Patient age, gender, and right ventricular and left ventricular VT were equally distributed. Acute success was achieved in 59 patients in the MNS group (82%) versus 27 (66%) patients in the MAN group (P = 0.046). Overall procedural time (177 ± 79 vs 232 ± 99 minutes, P < 0.01) and mean patient fluoroscopy time (27 ± 19 vs 56 ± 32 minutes, P < 0.001) were all significantly lower using MNS. In NSHD pts, higher acute success was achieved with MNS (83,7% vs 61.9%, P = 0.049), with shorter procedure times (151 ± 57 vs 210 ± 96, P = 0.011), whereas in SHD-VT these were not significantly different. No major complications occurred in the MNS group (0%) versus 1 cardiac tamponade and 1 significantly damaged ICD lead in the MAN group (4.9%, NS). After follow-up (20 ± 11 vs 20 ± 10 months, NS), VT recurred in 14 pts (23.7%) in the MNS group versus 12 pts (44.4%) in the MAN group (P = 0.047). CONCLUSIONS: The use of MNS offers advantages for ablation of NSHD-VT, while it offers similar efficacy for SHD-VT. (J Cardiovasc Electrophysiol, Vol. 23, pp. 948-954, September 2012).


Asunto(s)
Ablación por Catéter/métodos , Magnetismo , Cirugía Asistida por Computador/métodos , Taquicardia Ventricular/cirugía , Adulto , Anciano , Estudios de Casos y Controles , Ablación por Catéter/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad
18.
J Cardiovasc Electrophysiol ; 23(9): 938-44, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22587370

RESUMEN

UNLABELLED: Early Repolarization in Noncompaction Cardiomyopathy. BACKGROUND: Early repolarization (ER) is associated with malignant ventricular arrhythmias, including ventricular fibrillation (VF) and sudden cardiac death (SCD). One possible mechanism is increased trabeculation with deep intramyocardial invagination, carrying the Purkinje system deeper into the myocardium resulting in delayed depolarization and inhomogenous repolarization. Noncompaction cardiomyopathy (NCCM) is a recently classified, primary cardiomyopathy with excessive trabeculations. In these patients ventricular arrhythmias, including sustained VT and VF, occur frequently. The aim of this study was to determine the prevalence of ER in NCCM patients, especially in those primarily presenting with malignant ventricular arrhythmias or SCD. METHODS: We analyzed prospective data from our NCCM registry including 84 patients, median age: 40 (3-79) years. RESULTS: Fourteen patients (17%) initially presented with sustained VT (n = 5) or VF (n = 9) and 70 (83%) with heart failure or else. After the exclusion of 20 patients with the left bundle branch block, 25 (39%) NCCM patients had ER; 3 (6%) located in inferior leads, 14 (27%) in lateral leads, and 8 (15%) in both. None had ER in leads V1 to V3. In those presenting with VT/VF, 9/12 (75%) had ER (2 in inferior leads, 3 in lateral leads and 4 in both), versus 16/52 (31%) in the other patients (P = 0.02). If the NCCM population was dichotomized according to the presence or absence of ER, the long-term outcome for VT/VF appeared worse in the ER positive patients (P = 0.05). CONCLUSION: There is a high prevalence of ER in NCCM patients, especially in those who present with malignant ventricular arrhythmias. (J Cardiovasc Electrophysiol, Vol. 23, pp. 938-944, September 2012).


Asunto(s)
Arritmias Cardíacas/fisiopatología , Cardiomiopatías/fisiopatología , Electrocardiografía , Corazón/fisiopatología , Potenciales de Acción , Adolescente , Adulto , Anciano , Arritmias Cardíacas/complicaciones , Cardiomiopatías/complicaciones , Humanos , Persona de Mediana Edad , Prevalencia
19.
Europace ; 14(12): 1715-8, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22719063

RESUMEN

AIMS: Studies have shown that remote magnetic navigation is safe and effective for ablation of atrial arrhythmias, although optimal outcomes often require frequent manual manipulation of a circular mapping catheter. The Vdrive robotic system ('Vdrive') was designed for remote navigation of circular mapping catheters to enable a fully remote procedure. This study details the first human clinical experience with remote circular catheter manipulation in the left atrium. METHODS AND RESULTS: This was a prospective, multi-centre, non-randomized consecutive case series that included patients presenting for catheter ablation of left atrial arrhythmias. Remote systems were used exclusively to manipulate both the circular mapping catheter and the ablation catheter. Patients were followed through hospital discharge. Ninety-four patients were included in the study, including 23 with paroxysmal atrial fibrillation (AF), 48 with persistent AF, and 15 suffering from atrial tachycardias. The population was predominately male (77%) with a mean age of 60.5 ± 11.7 years. The Vdrive was used for remote navigation between veins, creation of chamber maps, and gap identification with segmental isolation. The intended acute clinical endpoints were achieved in 100% of patients. Mean case time was 225.9 ± 70.5 min. Three patients (3.2%) crossed over to manual circular mapping catheter navigation. There were no adverse events related to the use of the remote manipulation system. CONCLUSIONS: The results of this study demonstrate that remote manipulation of a circular mapping catheter in the ablation of atrial arrhythmias is feasible and safe. Prospective randomized studies are needed to prove efficiency improvements over manual techniques.


Asunto(s)
Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/instrumentación , Ablación por Catéter/instrumentación , Magnetismo/instrumentación , Robótica/instrumentación , Cirugía Asistida por Computador/instrumentación , Telemedicina/instrumentación , Fibrilación Atrial/diagnóstico , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Alemania , Humanos , Masculino , Micromanipulación/instrumentación , Persona de Mediana Edad , Países Bajos , Integración de Sistemas , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA