Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
J Xray Sci Technol ; 23(6): 727-36, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26756408

RESUMEN

The aim of this study was to investigate quantitatively the dosimetric factors that increase the risk of clinical complications of rib fractures or chest wall pain after stereotactic body radiation therapy (SBRT) to the lung. The correlations of clinical complications with standard-uptake values (SUV) and FDG-PET activity distributions from post-treatment PET-imaging were studied. Mean and maximum doses from treatment plans, FDG-PET activity values on post-SBRT PET scans and the presence of clinical complications were determined in fifteen patients undergoing 16 SBRT treatments for lung cancer. SBRT treatments were delivered in 3 to 5 fractions using 5 to 7 fields to prescription doses in the range from 39.0 to 60.0 Gy. The dose and FDG-PET activity values were extracted from regions of interest in the chest wall that matched anatomically. Quantitative evaluation of the correlation between dose deposition and FDG-PET activity was performed by calculating the Pearson correlation coefficient using pixel-by-pixel analysis of dose and FDG-PET activity maps in selected regions of interest associated with clinical complications. Overall, three of fifteen patients developed rib fractures with chest wall pain, and two patients developed pain symptoms without fracture. The mean dose to the rib cage in patients with fractures was 37.53 Gy compared to 33.35 Gy in patients without fractures. Increased chest wall activity as determined by FDG-uptake was noted in patients who developed rib fractures. Enhanced activity from PET-images correlated strongly with high doses deposited to the chest wall which could be predicted by a linear relationship. The local enhanced activity was associated with the development of clinical complications such as chest wall inflammation and rib fracture. This study demonstrates that rib fractures and chest wall pain can occur after SBRT treatments to the lung and is associated with increased activity on subsequent PET scans. The FDG-PET activity provides a useful parameter that can be used clinically to predict chest wall complication in lung patients.


Asunto(s)
Fluorodesoxiglucosa F18/farmacocinética , Neoplasias Pulmonares/cirugía , Traumatismos por Radiación/metabolismo , Radiocirugia/efectos adversos , Fracturas de las Costillas/etiología , Fracturas de las Costillas/metabolismo , Adulto , Anciano , Anciano de 80 o más Años , Dolor en el Pecho , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/metabolismo , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones/métodos , Dosis de Radiación , Traumatismos por Radiación/etiología , Traumatismos por Radiación/patología , Radiofármacos/farmacocinética , Reproducibilidad de los Resultados , Estudios Retrospectivos , Fracturas de las Costillas/diagnóstico por imagen , Sensibilidad y Especificidad , Estadística como Asunto , Pared Torácica/metabolismo , Pared Torácica/efectos de la radiación , Resultado del Tratamiento
2.
Gulf J Oncolog ; 1(21): 21-9, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27250884

RESUMEN

PURPOSE: To quantify the variations in the length and position of fiducial markers induced by motion in axial (ACT), helical (HCT) and cone-beam CT (CBCT) imaging and associated uncertainty in image-guided radiotherapy (IGRT) by measurement and modeling. METHODS: A mobile thorax phantom containing markers of various lengths was imaged using ACT, HCT and CBCT imaging. The phantom was imaged while stationary and moving where it was moved sinusoidally with different motion amplitudes and frequency. An analytical motion model was developed that predicts the localization accuracy of IGRT based on fiducial markers in mobile phantom with ACT, HCT and CBCT. RESULTS: The apparent lengths of the markers varied with the different motion patterns and CT imaging modalities. In CBCT, the apparent length of the markers increased linearly with the motion amplitude for both half-fan and full-fan modes. In HCT and ACT, the apparent length of the markers increased or decreased non-linearly with motion parameters and speed of the imaging couch. When the marker moved opposed to couch motion the apparent lengths decreased, while they increased when the phantom moved along the direction of the imaging couch as predicted by the motion model. The position of marker centers did not shift and distance between makers did not change in CBCT images. However, in HCT and ACT, the position of marker center and distance between markers varied depending on motion parameters during imaging. The marker center could move superiorly or inferiorly and the distance between markers could increase or decrease depending on the phase of motion as predicted by the motion model. CONCLUSIONS: The variations of marker length and position due to phantom motion were quantified by measurement and modeling. These variations may lead to large positioning uncertainties in patient setup and tumor localization based on IGRT with fiducial marker registration.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Marcadores Fiduciales , Humanos , Movimiento (Física) , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Incertidumbre
3.
Gulf J Oncolog ; 1(18): 54-63, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-26003106

RESUMEN

PURPOSE: To investigate quantitatively the deformation of the mammosite balloon, eccentricity of the source position and their effects on the dose delivered to the tumor lumpectomy site and critical structures. MATERIALS AND METHODS: The distances of the brachytherapy source to the surface of the mammosite balloon were measured in using radiographic images for fractions 1 to 10 for twelve patients. The dose at the balloon surface (nearly 680cGy) and prescription dose of 340cGy at 1cm from the balloon surface were calculated for the different fractions and their dependence on the balloon volume and source position were investigated. RESULTS: The position of the source can be offset from the center of the mammosite balloon by up to 6mm. Deformation of the balloon led to variations in its dimensions by up to 8mm. The dose at 1cm from the balloon surface that covers the lumpectomy site varied by up to 19% from 340cGy along the elongated diameter of the balloon and by up to 40% along the short diameter. Maximal doses to the skin, ribs and lung were 420cGy, 630cGy and 500cGy per fraction, respectively, which depended mostly on their distance from the balloon surface. CONCLUSION: The geometric variations in the shape of the balloon and position of the source can cause lack of dose coverage to the lumpectomy site or create hot dose spots in the surrounding normal tissue that might compromise intended clinical goals. Users as well as vendors should consider correction measures for the deformation of the balloons and the eccentricity of the position of the high dose source.

4.
J Comp Neurol ; 381(3): 335-52, 1997 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-9133572

RESUMEN

To examine the early determinants of cortical cytoarchitecture, we deleted specific neuronal classes in the primate visual cortex by ionizing irradiation at selected prenatal stages. Multiple doses of X-rays were delivered to the macaque monkey brain between embryonic day (E) 80 and E90 to block the division of cells destined to populate the superficial cortical layers, between E70 and E79 to eliminate neurons destined for the middle layers; and between E33 and E40 to delete neurons destined for the lateral geniculate nucleus (LGN) that project to the cortex. All animals were killed after birth, and their brains were processed for histological and electron microscopic analyses. Cell density and number in the LGN and visual cortex were determined by using three-dimensional, computer-aided morphometry. In animals irradiated with low doses (total of approximately 200 cGy) during the genesis of the LGN but before the onset of corticogenesis (E33-40), the LGN was reduced in both volume and number of neurons. Area 17 in these animals displayed only slight changes in cortical thickness, cell density, and area-specific cytoarchitectonic features, whereas the total surface devoted to area 17 was significantly diminished. In contrast, animals irradiated with low doses during the period of corticogenesis, after the completion of the LGN genesis, showed no significant change in the volume of the LGN or in the number of its cells. Moreover, in these animals, the surface of area 17 was not significantly altered, although the cortical layers generated at the time of irradiation had a significantly lower density and total number of cells, whereas the layers generated before and after the period of irradiation were spared. In contrast, cases exposed to high doses of X-ray (total > 300 cGy) showed more severe effects, including all layers. However, layers normally generated during irradiation were depleted and consisted of cell-sparse strata populated by densely packed neuropil (axons, small dendrites, dendritic spines, and synaptic boutons). These cell-sparse strata were situated deeper in the early irradiated animals than in the later irradiated animals, and their laminar position changed abruptly at the area 17/18 border. These results show that low doses of irradiation in a slowly developing primate brain can be used effectively to eliminate targeted classes of neurons before they reach their final position, providing an opportunity to examine the role of cell-cell interactions in the formation of circuitry and the role of specific cell classes in cortical development.


Asunto(s)
Macaca mulatta/fisiología , Neuronas/citología , Corteza Visual/crecimiento & desarrollo , Corteza Visual/efectos de la radiación , Animales , Comunicación Celular/fisiología , Recuento de Células , Tamaño de la Célula , Relación Dosis-Respuesta en la Radiación , Femenino , Cuerpos Geniculados/citología , Cuerpos Geniculados/crecimiento & desarrollo , Edad Gestacional , Microscopía Electrónica , Neuronas/efectos de la radiación , Neuronas/ultraestructura , Embarazo , Efectos Tardíos de la Exposición Prenatal , Corteza Visual/citología , Vías Visuales/fisiología
5.
Int J Radiat Oncol Biol Phys ; 40(5): 1137-40, 1998 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-9539569

RESUMEN

PURPOSE: The prone position has been advocated for women with large pendulous breasts undergoing breast-conserving treatment with radiation therapy. However, there is no information in the literature regarding the coverage of the target volume with this technique. The purpose of this study was to evaluate the effectiveness of the prone treatment position in including at least the biopsy cavity with a 2-cm margin. METHODS AND MATERIALS: Eleven consecutive patients who underwent CT simulation in the prone position were included in this study. Patients underwent CT simulation in the prone position using a flat platform containing an aperture for the breast to hang through in a dependent fashion. CT slices were 5-mm thick taken at 3-mm intervals. The biopsy cavity was localized and outlined on sequential CT images using the surgical clips (when present) as well as the residual seroma. A 2-cm margin was included around the biopsy cavity to define the minimal target volume (mTV). Lateral fields were used for treatment planning. The beam arrangements were considered adequate if the mTV was totally included in the lateral fields. RESULTS: Median age of the patient population was 55 years. Bra sizes ranged from 36A-44DD. The majority of patients had mammographically detected T1 lesions. Median volume of the biopsy cavity was 48 cm3. Five of 11 (45%) patients underwent reexcision of the biopsy cavity, and 6 of 11 (55%) had surgical clips placed in the biopsy cavity. Overall, 8 of 11 (73%) patients did not have the entire mTV included in the lateral opposed tangential fields in the prone position. This was especially true in patients whose biopsy cavity extended down to the chest wall. There were no other clinical factors that could predict for the adequacy of coverage in the prone position. CONCLUSION: Special attention must be paid to the location of the surgical clips to determine the proximity of the biopsy cavity to the chest wall, or CT simulation should be performed to determine the exact location of the biopsy cavity prior to selecting patients with large pendulous breasts for treatment in the prone position.


Asunto(s)
Neoplasias de la Mama/radioterapia , Posición Prona , Adulto , Anciano , Neoplasias de la Mama/patología , Femenino , Humanos , Persona de Mediana Edad
6.
Int J Radiat Oncol Biol Phys ; 33(4): 925-30, 1995 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-7591904

RESUMEN

PURPOSE: To determine whether retrograde urethrogram, or the combination of computed tomography (CT) scan/retrograde urethrogram is more accurate for locating the magnetic resonance imaging (MRI) designated prostatic apex, and to determine whether patients treated in our department with CT/urethrogram are receiving the prescribed minimal dose to the MRI identified prostatic apex. METHODS AND MATERIALS: Seventeen patients with early stage prostate cancer were enrolled in a prospective study to determine the location of the prostatic apex. All of the patients agreed to undergo MRI in addition to retrograde urethrogram, and CT of the pelvis for three dimensional (3D) treatment planning. The prostatic apex was identified on each of the studies and measured from a reference point (the most superior portion of the pubic symphysis). The location of the prostatic apex as measured by retrograde urethrogram alone and by CT/urethrogram was compared to the location of the prostatic apex as measured by MRI. Because of MRI's ability for multiplanar capabilities, and high soft tissue contrast in the region of the prostate, it was assumed to be more accurate for identifying the location of the prostatic apex, and was used as the gold standard. RESULTS: The location of the prostatic apex as determined by the urethrogram alone was on average 5.8 mm caudad to the location on MRI (p = 0.012), while the location of the prostatic apex as determined by CT/urethrogram was 3.1 mm caudad to the location on MRI (p = 0.150). If the prostatic apex is defined at 12 mm instead of 10 mm above the urethrogram tip, the statistically significant difference between the urethrogram and the MRI is no longer present. Based on these results, all 17 patients received the minimum prescribed dose to the prostatic apex. CONCLUSION: CT/urethrogram correlates better with the location of the MRI determined prostatic apex, than does the urethrogram alone. Locating the prostatic apex 12 mm above the urethrogram tip better localizes the prostatic apex, while also avoiding the error that can potentially lead to a geographic miss. This in fact assures that all of our patients receive the minimum prescribed dose to this critical site of extraprostatic extension, while also decreasing the amount of normal tissue that is included in the treatment volume.


Asunto(s)
Imagen por Resonancia Magnética , Próstata/patología , Neoplasias de la Próstata/patología , Tomografía Computarizada por Rayos X , Humanos , Masculino , Estudios Prospectivos , Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador , Vesículas Seminales/diagnóstico por imagen , Vesículas Seminales/patología , Uretra/diagnóstico por imagen
7.
Int J Radiat Oncol Biol Phys ; 35(5): 925-33, 1996 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-8751401

RESUMEN

PURPOSE: To evaluate prognostic factors and treatment outcome for high risk pathological Stage I and II endometrial cancer patients treated with consistent postoperative radiation therapy (RT) in a single institution and to compare these results to series where RT was variably applied. METHODS AND MATERIAL: Between 1986 and 1993, 98 pathologic Stage I and II endometrial cancer patients received postoperative RT at the Fox Chase Cancer Center. Papillary serous and clear cell histologies were excluded. Fifty-five patients underwent lymph node evaluation. In 17 patients, RT consisted of intracavitary brachytherapy alone to a median dose of 21 Gy, and in 81 patients, RT consisted of external beam RT to a median dose of 45 Gy followed by intracavitary brachytherapy to a median dose of 12 Gy. Intracavitary brachytherapy generally consisted of three high dose rate implants with the dose prescribed to a depth of 0.5 cm. Median follow up was 47 months. RESULTS: The 5-year overall survival (OS), disease free survival (DFS), and freedom from pelvic recurrence (FPR) rates were 83, 85, and 89%, respectively. Pelvic recurrence either as the sole pattern of failure or combined with distant metastases was seen in 2 and 7% of patients, respectively. Distant metastases alone occurred in 4% of the patients. Univariate analysis of prognostic factors including age, grade, capillary lymphatic space invasion, depth of myometrial invasion, type of lymph node evaluation, pathologic stage, the use of brachytherapy and the number of risk factors was performed for OS, DFS, FPR, and FDM. Capillary lymphatic space invasion was the only statistically significant predictor for reduced DFS. Absence of lymph node dissection as well as a higher number of risk factors showed a trend toward poorer DFS (p = 0.06 for both). Multivariate analysis revealed older age to be the only factor significant for reduced DFS, with the presence of capillary lymphatic space invasion and the absence of a lymph node dissection showing a trend toward poorer outcome (p = 0.07). CONCLUSIONS: The results of this study suggest a continued role for the use of postoperative RT in the treatment of patients with high risk endometrial cancer and will be compared to other series with similar high-risk factors.


Asunto(s)
Neoplasias Endometriales/radioterapia , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Braquiterapia , Terapia Combinada , Supervivencia sin Enfermedad , Neoplasias Endometriales/patología , Neoplasias Endometriales/cirugía , Femenino , Humanos , Persona de Mediana Edad , Análisis Multivariante , Recurrencia Local de Neoplasia , Estadificación de Neoplasias , Factores de Riesgo , Insuficiencia del Tratamiento
8.
Int J Radiat Oncol Biol Phys ; 32(3): 753-61, 1995 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-7790262

RESUMEN

PURPOSE: The incidence of adenocarcinoma of the esophagus is increasing, but the optimal treatment for this disease is unknown. We evaluated the efficacy of chemoradiation and chemoradiation followed by esophagectomy as treatment for adenocarcinoma of the esophagus in sequential prospective nonrandomized phase II studies. METHODS AND MATERIALS: Between May 1981 and June 1992, all previously untreated patients (N = 35) with potentially resectable adenocarcinoma of the esophagus (clinical Stage I or II) were treated with curative intent in sequential prospective Phase II studies. From May 1981 to August 1987, 11 patients (median age 66) were treated with concurrent chemotherapy [mitomycin C, and 5-fluorouracil (5-FU)] and radiotherapy to a median dose of 60 Gy (CRT group). From September 1987 to June 1992, 24 patients (median age 65) were treated with the same regimen of chemoradiation followed by planned esophagectomy (CRT+PE group). Of these, 12 patients (median age 62) actually underwent esophagectomy (CRT+E subgroup). RESULTS: The median overall survival was 19 months for the CRT group and 15 months for the CRT+PE group. For the CRT+E subgroup, the median overall survival was 33 months. The 3-year actuarial overall survival for the CRT and the CRT+PE groups were 36 and 28% (p = 0.949). The subset of patients treated with chemoradiation followed by esophagectomy had a 3-year actuarial overall survival of 33% (p = 0.274). The 3-year actuarial freedom from local failure rates were similar: 62% in the CRT group vs. 58% in the CRT+PE group. Of the 12 patients who underwent esophagectomy (CRT+E group), 9 (75%) were free of local failure. Four of 12 (33%) patients had no pathologic evidence of malignancy in their surgical specimen. Six of 11 patients (55%) in the CRT group were free of local failure at the time of analysis. Two of five patients in this group who had local recurrence at 2 and 10 months underwent surgical salvage with subsequent survivals of 20 and 100 months, respectively. Treatment-related mortality was 0 out of 11 in the CRT group and 2 out of 24 in the CRT+PE group. Dysphagia relief was similar in the CRT group vs. the CRT+E subgroup; however, a greater percentage of patients treated with chemoradiation alone had normal long-term swallowing function when compared to those patients also undergoing esophagectomy (100% vs. 73%). CONCLUSION: High-dose chemoradiation alone appears to provide similar survival and relief of dysphagia compared with high-dose chemoradiation followed by esophagectomy for patients with potentially resectable esophageal adenocarcinoma. Local failure may be higher in patients undergoing chemoradiation compared to chemoradiation followed by esophagectomy, but surgical salvage is possible, thus providing similar overall local control. However, because of the small number of patients in each group, these treatment modalities need to be further evaluated in a prospective randomized Phase III study.


Asunto(s)
Adenocarcinoma/tratamiento farmacológico , Adenocarcinoma/radioterapia , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Neoplasias Esofágicas/tratamiento farmacológico , Neoplasias Esofágicas/radioterapia , Adenocarcinoma/mortalidad , Adenocarcinoma/patología , Adulto , Anciano , Anciano de 80 o más Años , Terapia Combinada , Neoplasias Esofágicas/mortalidad , Neoplasias Esofágicas/patología , Femenino , Fluorouracilo/administración & dosificación , Humanos , Masculino , Persona de Mediana Edad , Mitomicina/administración & dosificación , Estudios Prospectivos , Dosificación Radioterapéutica , Insuficiencia del Tratamiento
9.
Int J Radiat Oncol Biol Phys ; 20(5): 1053-60, 1991 May.
Artículo en Inglés | MEDLINE | ID: mdl-2022505

RESUMEN

Four patients with intracranial neoplasms, two with malignant gliomas and two with brain metastases, were treated with stereotactic radiotherapy. Patients received between 15 and 27.5 Gray of photon irradiation to the central tumor target point; the 80% isodose line covered the periphery of the tumor as determined by contrast enhanced computed tomography. Patients underwent a sequence of three Positron Emission Tomographic scans using [18F]-fluorodeoxyglucose (PET-FDG)--a baseline scan the day before treatment, and follow-up scans 1 and 7 days after treatment. Ratios between the maximal tumor regional cerebral metabolic rate for glucose (rCMRGlu) (T*) and the contralateral remote white matter rCMRGlu (RW), that is, the glucose uptake ratio (T*/RW), were calculated. The percent change in ratios relative to each patient's baseline scan were calculated. Ratios increased 25% to 42% 1 day post-radiotherapy, then decreased to between 10% above and 12% below the baseline value 7 days post-radiotherapy. The T*/RW increased acutely after stereotactic radiotherapy in a fashion similar to that previously described following chemotherapy with a complex multi-drug regimen. A common metabolic pathway may underlie the increase in T*/RW after these different treatments.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Glucosa/metabolismo , Técnicas Estereotáxicas , Neoplasias Encefálicas/metabolismo , Neoplasias Encefálicas/secundario , Carcinoma de Células Renales/metabolismo , Carcinoma de Células Renales/radioterapia , Carcinoma de Células Renales/secundario , Desoxiglucosa/análogos & derivados , Radioisótopos de Flúor , Fluorodesoxiglucosa F18 , Glioma/diagnóstico por imagen , Glioma/metabolismo , Glioma/radioterapia , Humanos , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/metabolismo , Neoplasias Renales/radioterapia , Melanoma/metabolismo , Melanoma/radioterapia , Melanoma/secundario , Tomografía Computarizada de Emisión
10.
Radiat Res ; 146(3): 267-75, 1996 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-8752304

RESUMEN

Radiation-induced apoptosis detected by gel electrophoresis was measured in cells of three human prostate carcinoma cell lines (TSU, PC-3 and DU-145) and compared to their intrinsic radiosensitivities as measured by clonogenic assays. The intrinsic radiosensitivities of each cell line were defined by their alpha and beta coefficients and their surviving fraction at 2 Gy, derived from complete survival curves. The temporal expression and kinetics of radiation-induced apoptosis for DU-145 cells, the human prostate carcinoma cell line which expressed the highest rate of radiation-induced apoptosis, was characterized further by differential sedimentation and the immunofluorescence assay (Apoptag) which was specific for 3'-OH ends in cellular DNA. Cell viability was measured microscopically with trypan blue staining. Cell survival after various doses was computer-fitted to either a simple linear or a linear-quadratic equation. Twenty-four hours after a 10-Gy dose of 137Cs gamma rays, DNA fragmentation to nucleosome multimers was strongly expressed in only DU-145 cells. In this cell line, when centrifugation at 12,000g for 10 min was used to separate fragmented from large molecular weight DNA, the proportion of DNA in the supernatant increased to a maximum of approximately 17% of the total by 10-12 h after radiation treatment. Cell death 24 h after irradiation measured by trypan blue exclusion assays followed single-hit kinetics up to 80 Gy. The proportion of cells which were labeled with Apoptag displayed single-hit kinetics and yielded the same inactivation coefficient as measured by trypan blue. Together, these data indicate that the rapid (24 h) inactivation of irradiated DU-145 cells results from apoptosis and accounts for about 5% of the single-hit killing measured by clonogenic assay. Temporal studies of radiation-induced killing of DU-145 cells distinguished this rapid mechanism of cell death from the major mechanism (72-144 h). These may correlate with apoptosis and proliferative cell death, respectively. Of the three prostate cancer cell lines investigated, only DU-145 cells displayed significant levels of radiation-induced DNA fragmentation and rapid cell death, with characteristics of apoptosis. This mechanism of cell death was complete by 24 h after irradiation and was well separated in time from the death of cells by the major mechanisms which occurred after 72 h, and accounted for about 5% of cell inactivation by a single-hit mechanism.


Asunto(s)
Apoptosis , ADN de Neoplasias/efectos de la radiación , Próstata/efectos de la radiación , Neoplasias de la Próstata/patología , Línea Celular , Radioisótopos de Cesio , Neoplasias del Colon , ADN de Neoplasias/aislamiento & purificación , Relación Dosis-Respuesta en la Radiación , Rayos gamma , Humanos , Cinética , Linfoma , Masculino , Células Tumorales Cultivadas , Ensayo de Tumor de Célula Madre
11.
Monaldi Arch Chest Dis ; 51(1): 42-9, 1996 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-8901321

RESUMEN

In the past 15 yrs, a number of investigators have applied spectral analysis to respiratory sounds recorded from the chest wall or the trachea in order to objectively characterize them and to relate them with different pulmonary diseases. In the present study, we have applied multivariate linear discriminant analysis to the spectral features of respiratory sounds. Lung sounds and the airflow velocity were recorded from 15 normal adults and 37 patients falling into three different disease categories: chronic obstructive lung disease, bronchial asthma and bronchiectasis. All patients had prominent adventitious lung sounds (i.e. either wheezes or crackles). Amplitude spectra of five selected inspiratory and expiratory sound segments of each subject were calculated using the Fast Fourier Transform algorithm. Multi-variate linear discriminant analysis was then applied to the normalized and averaged spectral area values calculated for 10 unequal and arbitrarily selected frequency bands for each patient in the frequency range between 80 Hz and 1 kHz. Inspiratory and expiratory sounds were treated separately. Discriminant functions were computed from the spectral area values and plotted on graphs to classify the subjects into one of the disease categories or as normal (training set). While some separation was achieved among the different disease groups, a clearer separation was evident between normals and patients as a whole on the basis both of inspiratory and expiratory sounds. Inspiratory and expiratory sound frequency bands having the largest weights in classification were determined. Admittedly, the specific results of this study are preliminary or even tentative in view of the inadequacies of sound recording and signal conditioning techniques that were available to us at the time of recording. However, we believe that the investigation serves to illustrate the potential of multivariate discriminant analysis in the diagnostic classification of patients on the basis of their lung sound patterns. We suggest that this technique be considered by investigators involved in lung sound research, because it also allows other patient variables to be combined with the selected parameters of lung sounds.


Asunto(s)
Asma/diagnóstico , Bronquiectasia/diagnóstico , Enfermedades Pulmonares Obstructivas/diagnóstico , Análisis Multivariante , Ruidos Respiratorios , Adulto , Asma/fisiopatología , Bronquiectasia/fisiopatología , Diagnóstico Diferencial , Análisis Discriminante , Femenino , Volumen Espiratorio Forzado , Humanos , Enfermedades Pulmonares Obstructivas/fisiopatología , Masculino , Valor Predictivo de las Pruebas , Ruidos Respiratorios/fisiopatología , Sensibilidad y Especificidad , Capacidad Vital
12.
Integr Physiol Behav Sci ; 34(4): 219-26, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10791605

RESUMEN

In a two-day, two-session experiment where smokers male and female college-student subjects worked on a cognitive verbal task during either the first or second day, and on a cognitive spatial task on the second or first day, smoking was manipulated as an acute independent variable by requiring 10+ hours of pre-experimental abstention, and providing a cigarette during the 15-minute rest period between the two sessions. Non-smoker female and male subjects underwent the same experiment, and hence served as controls for the effects of this acute-smoking manipulation. Overall adaptation (decreased arousal) to the experiment was manifested in a significant increase in skin resistance level (SRL) in all subjects, but when this adaptation effect was statistically controlled, there was a significant smokers by sex interaction during the verbal task only, such that SRL was increased by the cigarette in males, but decreased in females. In contrast, the same analysis indicated only a marked increase in heart-rate (HR) due to smoking, which was unaffected either by sex or by whether the task was the verbal or the (easier) spatial one. We interpret the SRL results as reflecting a sex difference in the direction of transient psychological arousal, and discuss it in relation to evidence in the literature based on self reports, and to evidence (based on HR in this study and on blood pressure in other studies) on physiological (cardiovascular) arousal. Key Words: Electrodermal activity, heart-rate, psychological vs. physiological, verbal and spatial cognitive tasks.


Asunto(s)
Cognición/fisiología , Respuesta Galvánica de la Piel/fisiología , Frecuencia Cardíaca/fisiología , Desempeño Psicomotor/fisiología , Fumar/fisiopatología , Adolescente , Adulto , Nivel de Alerta/fisiología , Femenino , Humanos , Masculino , Caracteres Sexuales , Cese del Hábito de Fumar/psicología , Percepción Espacial/fisiología
13.
J Med Imaging Radiat Oncol ; 58(3): 384-91, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24592817

RESUMEN

INTRODUCTION: We aim to quantify the variations in the gross tumour volume (GTV) during a course of stereotactic body radiotherapy (SBRT) and determine its impact on dosimetric coverage of the GTV. METHODS: The GTVs and dose coverage for 14 patients with 16 primary non-small-cell lung tumours treated with SBRT were investigated. Initial GTVs were calculated from treatment planning CT scans. The prescribed doses ranged from 48 to 60 Gy in three to five fractions. Before each treatment, patients underwent a CBCT scan. For each CBCT scan, the GTV and the dose received by the GTV were determined and followed during the course of therapy. RESULTS: There was considerable variation in the measured GTVs during the course of therapy. Increases of up to 63.3% of volume measured by initial CBCT were detected during the first few fractions, after which GTV tended to decrease. Dose coverage (V95) for any given fraction deviated no more than 5% from optimised coverage obtained in the initial treatment plan. In the long term, all patients with follow-up scans demonstrated tumour shrinkage with no radiographic evidence of tumour recurrence. CONCLUSION: GTV, as evaluated in this study, demonstrates an initial increase in volume followed by a subsequent decrease. This volume change needs to be considered in the design of treatment plans and assignment of treatment margins.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/patología , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Imagenología Tridimensional/métodos , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/radioterapia , Radiocirugia/métodos , Carga Tumoral/efectos de la radiación , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Dosificación Radioterapéutica , Radioterapia Guiada por Imagen/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
14.
Gulf J Oncolog ; 1(13): 6-14, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23339976

RESUMEN

PURPOSE: To investigate enlargement of prostate volume by edema during brachytherapy seed implantation and develop a nomogram model to calculate air-kerma strength (AKS) required for implantation of the enlarged transient prostatic volume. MATERIALS AND METHODS: The prostate volume was measured prior and after seed implantation using trans-rectal ultrasound imaging in the operating room to obtain volume enlargement. A nomogram model was developed that calculates AKS required for implantation of the enlarged transient prostate volume with optimal dose coverage. RESULTS: The measured prostate enlargement in this study was up to 60% of the initial volume. The effective prostatic volume enlargement was calculated for three isotopes: 125I, 103Pd and 131Cs. The effective volume enlargement for 125I implants was relatively small (< 10%) because of its long half-life. For 103Pd and 131Cs with short half-lives, additional AKS up to 20% and 30%, respectively, might be required to provide appropriate dose coverage of possible enlarged prostatic volumes. CONCLUSIONS: Prostate volume enlargement should be considered to obtain optimal dose coverage particularly for short half-life isotopes such as 131Cs and 103Pd. The nomogram model developed in this work provides the AKS required for implants with a wide range of prostatic volume enlargements (5-100%) for three isotopes. KEYWORDS: prostate brachytherapy; nomogram; air-kerma strength; edema; volume enlargement.


Asunto(s)
Braquiterapia , Radioisótopos de Yodo , Edema , Humanos , Masculino , Paladio , Neoplasias de la Próstata , Radioisótopos/uso terapéutico , Dosificación Radioterapéutica , Semillas , Tomografía Computarizada por Rayos X
15.
Med Phys ; 39(6Part5): 3652, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28517618

RESUMEN

PURPOSE: To determine localization errors of fiducial markers using axial (ACT) and helical CT (HCT), cone beam CT (CBCT) and kV imaging. METHODS AND MATERIALS: A thorax phantom containing markers of various sizes (2.5, 5, 10, 20mm) was imaged using ACT, HCT, CBCT and kV imaging. The phantom was imaged with and without motion (15mm amplitude, 15 cycles/min). CT images were reconstructed at 0.625, 1.25, 2.5 and 5mm thickness. Marker location and length were measured using axial and coronal imaging. RESULTS: The measured marker size increased almost linearly with increased slice thickness used in CT reconstruction with ACT for the stationary phantom. In HCT, the marker size varied non-linearly with increase in slice thickness. Motion of the phantom induced further blurring and shifts of the center of the marker with different sizes. The 10 mm marker was elongated up to 13.5 mm and 16.2 mm in the ACT and HCT, respectively. The markers were elongated up to nearly 26 mm using axial and helical scanning modes by phantom motion. The displacement of maker center was more prominent in the HCT with a shift up to 2 mm due to slice thickness for stationary phantom. The marker center was displaced by up to 18 and 22 mm using ACT and HCT, respectively, which was even higher than 15 mm motion amplitude. KV imaging produced the sharpest marker image with the least difference between actual and measured marker sizes. CONCLUSION: Increase in slice thickness enlarged the apparent marker size and displaced the maker center in ACT and HCT. Motion led to further enlargement in the maker size and displacement of maker center that depended on the motion amplitude. These effects should be considered in CT-based image-guided radiation therapy to ensure accurate tumor localization and patient positioning with implanted markers.

16.
Med Phys ; 39(6Part19): 3838, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28517085

RESUMEN

PURPOSE: This study aims to evaluate treatment plans generated by Step- and-Shoot (SS), Sliding Window (SW) and Volumetric Modulated Arc Therapy (VMAT) in order to assess the differences in dose volume histograms of planning target volume (PTV) and organs at risk (OAR), conformity indices, radiobiological evaluations, and plan quality for prostate cancer cases. METHODS: Six prostate cancer patients treated in our center were selected for this retrospective study. Treatment plans were generated with Eclipse version 8.9 using 10 MV photon beams. For VMAT, Varian Rapid Arc with 1 or 2 arcs, and for SS and SW IMRT, 7-9 fields were used. Each plan had three PTVs with prescription doses of 81, 59.4, and 45 Gy to prostate, to prostate and lymph nodes, and to pelvis, respectively. Doses to PTV and OAR and the conformal indices (COIN) were compared among three techniques. The equivalent uniform dose (EUD), tumor control probability (TCP) and normal tissue complication probability (NTCP) was also calculated and compared. RESULTS: The mean doses to the PTV prostate on average were 83 Gy and the percent differences of mean dose among all techniques were below 0.28. For bladder and rectum, the percent differences of mean dose among all techniques were below 2.2. The COIN did not favour any particular delivery method over the other. The TCP was higher with SS and SW for four patients and higher with VMAT for two patients. The NTCP for the rectum was the lowest with VMAT in all patients except one. CONCLUSIONS: Preliminary data shows similar target coverage in general. We will extend our study to include 15 patients to compare different approaches with statistics. We will attempt to define characteristics predictive of the superior delivery technique.

17.
Med Phys ; 39(6Part9): 3699, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28519032

RESUMEN

PURPOSE: Evaluate the dosimetric impact of daily setup error and inter-fraction organ motion on the radiation treatment plan. METHODS: Twelve patients undergoing definitive IMRT treatments for prostate cancer were evaluated. All patients underwent fiducial marker placement prior to treatment planning CT scan, and were treated to a dose of 8100cGy given in 45 fractions. We retrospectively created a plan for each treatment day that had a shift available. To calculate the dose the patient would have received with no setup correction, we mathematically 'negated' the shift by moving the isocenter in the opposite direction of the shift. The individualized daily plans were combined to generate an overall plan sum. The dose distribution from these uncorrected plans was compared to the actual treatment plans. RESULTS: A total of 390 shifts were negated and their corresponding plans evaluated. The mean isocenter shift based on the location of the fiducial markers was 3.3±6.5mm to the right, 1.6±5.1mm posteriorly, and 1.0±5.0mm along the caudal direction. The mean D95 dose when setup error was corrected and uncorrected for the PTV8100 volume was 8089cGy and 7303cGy (p < 0.001) and for prostate volume was 8228cGy and 7844cGy (p < 0.002). The mean V95 values when setup error was corrected and uncorrected for the PTV8100 volume was 99.9% vs. 87.3% (p < 0.0001). At an individual level, the difference in D95 value approached 1200cGy for the prostate volume and 2000cGy for the PTV8100 volume. There was no statistically significant difference in the D35 parameter for the surrounding normal tissue except for the dose received by the right hip and the penile bulb. CONCLUSION: This work indicates that significant underdosing, approaching 2000cGy for the PTV8100 volume, can occur as a Result of inaccurate patient setup, and emphasizes the importance of accurate patient setup and target localization.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA