1.
J Card Fail ; 28(6): 963-972, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35041933

RESUMEN

OBJECTIVE: Patients with heart failure (HF) are at an increased risk of hospital admissions. The aim of this report is to describe the feasibility, safety and accuracy of a novel wireless left atrial pressure (LAP) monitoring system in patients with HF. METHODS: The V-LAP Left Atrium Monitoring systEm for Patients With Chronic sysTOlic & Diastolic Congestive heart Failure (VECTOR-HF) study is a prospective, multicenter, single-arm, open-label, first-in human clinical trial to assess the safety, performance and usability of the V-LAP system (Vectorious Medical Technologies) in patients with New York Heart Association class III HF. The device was implanted in the interatrial septum via a percutaneous, trans-septal approach guided by fluoroscopy and echocardiography. Primary endpoints included the successful deployment of the implant, the ability to perform initial pressure measurements and safety outcomes. RESULTS: To date, 24 patients have received implants of the LAP-monitoring device. No device-related complications have occurred. LAP was reported accurately, agreeing well with wedge pressure at 3 months (Lin concordance correlation coefficient = 0.850). After 6 months, New York Heart Association class improved in 40% of the patients (95% CI = 16.4%-63.5%), while the 6-minute walk test distance had not changed significantly (313.9 ± 144.9 vs 232.5 ± 129.9 meters; P = 0.076). CONCLUSION: The V-LAP left atrium monitoring system appears to be safe and accurate.


Asunto(s)
Presión Atrial , Insuficiencia Cardíaca , Cateterismo Cardíaco , Humanos , Estudios Prospectivos , Volumen Sistólico
2.
Internist (Berl) ; 63(2): 230-237, 2022 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-34762155

RESUMEN

BACKGROUND: Patients with atrial fibrillation are at a significantly increased risk of thromboembolic events, especially ischemic strokes. Oral anticoagulation reduces this risk, but cannot be used in some patients for various reasons and is associated with a relevantly increased risk of bleeding. As an alternative for prophylaxis of thromboembolic events in patients with atrial fibrillation, there are different options of left atrial appendage closure. AIM: This article explains the possibilities of interventional atrial occlusion as well as the suitable patient clientele using an overview of the currently available systems for atrial occlusion, a guideline for patient selection and a summary of the current scientific data. CONCLUSION AND AVAILABLE SCIENTIFIC DATA: In carefully selected patients suffering from atrial fibrillation with relative or absolute contraindications for oral anticoagulation, interventional closure of the atrial appendage is a safe alternative for prophylaxis against thromboembolic events. The currently available scientific evidence from randomized controlled trials is sparse. Nevertheless, extensive amounts of registry study data suggest a benefit, while the results of several large randomized controlled trials are expected in the coming years.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Tromboembolia , Anticoagulantes/efectos adversos , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Humanos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Tromboembolia/etiología , Tromboembolia/prevención & control , Resultado del Tratamiento
3.
Infect Immun ; 89(11): e0037621, 2021 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-34460287

RESUMEN

Liver transplantation (LT) is a life-saving strategy for patients with end-stage liver disease, hepatocellular carcinoma, and acute liver failure. LT success can be hampered by several short-term and long-term complications. Among them, bacterial infections, especially those due to multidrug-resistant germs, are particularly frequent, with a prevalence between 19 and 33% in the first 100 days after transplantation. In the last decades, a number of studies have highlighted how the gut microbiota (GM) is involved in several essential functions to ensure intestinal homeostasis, becoming one of the most important virtual metabolic organs. The GM works through different axes with other organs, and the gut-liver axis is among the most relevant and investigated ones. Any alteration or disruption of the GM is defined as dysbiosis. Peculiar phenotypes of GM dysbiosis have been associated with several liver conditions and complications, such as chronic hepatitis, fatty liver disease, cirrhosis, and hepatocellular carcinoma. Moreover, there is growing evidence of the crucial role of the GM in shaping the immune response, both locally and systemically, against pathogens. This paves the way to the manipulation of the GM as a therapeutic instrument to modulate infectious risk and outcome. In this minireview, we provide an overview of the current understanding of the interplay between the gut microbiota and the immune system in liver transplant recipients and the role of the former in infections.


Asunto(s)
Infecciones Bacterianas/etiología , Microbioma Gastrointestinal/fisiología , Sistema Inmunológico/fisiología , Trasplante de Hígado/efectos adversos , Infecciones Bacterianas/inmunología , Farmacorresistencia Bacteriana Múltiple , Disbiosis , Trasplante de Microbiota Fecal , Interacciones Microbiota-Huesped , Humanos , Cirrosis Hepática/complicaciones , Cirrosis Hepática/microbiología , Índice de Severidad de la Enfermedad
4.
J Card Surg ; 36(9): 3308-3316, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34173273

RESUMEN

BACKGROUND: During the Italian Phase-2 of the coronavirus pandemic, it was possible to restart elective surgeries. Because hospitals were still burdened with coronavirus disease 2019 (COVID-19) patients, it was focal to design a separate "clean path" for the surgical candidates and determine the possible effects of major surgery on previously infected patients. METHODS: From May to July 2020 (postpandemic peak), 259 consecutive patients were scheduled for elective cardiac surgery in three different centers. Our original roadmap with four screening steps included: a short item questionnaire (STEP-1), nasopharyngeal swab (NP) (STEP-2), computed tomography (CT)-scan using COVID-19 reporting and data system (CO-RADS) scoring (STEP-3), and final NP swab before discharge (STEP-4). RESULTS: Two patients (0.8%) resulted positive at STEP-2: one patient was discharged home for quarantine, the other performed a CT-scan (CO-RADS: <2), and underwent surgery for unstable angina. Chest-CT was positive in 6.3% (15/237) with mean CO-RADS of 2.93 ± 0.8. Mild-moderate lung inflammation (CO-RADS: 2-4) did not delay surgery. Perioperative mortality was 1.15% (3/259), and cumulative incidence of pulmonary complications was 14.6%. At multivariable analysis, only age and cardiopulmonary bypass (CPB) time were independently related to pulmonary complications composite outcome (age >75 years: odds ratio [OR]: 2.6; 95% confidence interval [CI]: 1.25-5.57; p = 0.011; CPB >90 min. OR: 4.3; 95% CI: 1.84-10.16; p = 0.001). At 30 days, no periprocedural contagion and rehospitalization for COVID-19 infections were reported. CONCLUSIONS: Our structured roadmap supports the safe restarting of an elective cardiac surgery list after a peak of a still ongoing COVID-19 pandemic in an epicenter area. Mild to moderate CT residuals of coronavirus pneumonia do not justify elective cardiac surgery procrastination.


Asunto(s)
COVID-19 , Procedimientos Quirúrgicos Cardíacos , Anciano , Humanos , Italia/epidemiología , Pandemias , SARS-CoV-2
5.
Ther Drug Monit ; 42(4): 643-647, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32701254

RESUMEN

BACKGROUND: There is extensive evidence to show that pre-exposure prophylaxis (PrEP) using tenofovir disoproxil fumarate (TDF)-based formulations dramatically reduces the risk of HIV acquisition among individuals without HIV infection. Here, the authors aim to compare tenofovir plasma predose concentrations in subjects taking PrEP daily versus on demand and using different TDF-based generic formulations. METHODS: Subjects providing informed signed consent for the measurement of tenofovir plasma levels were included in the study. Predose drug concentrations were stratified according to PrEP administration and the type of TDF-based formulation. The control group consisted of patients with HIV infection who were matched for renal function and were administered branded TDF that was not combined with boosted-antiretroviral drugs. RESULTS: The study consisted of 100 subjects (mean age, 39 ± 10 years; body weight, 77 ± 11 kg). A wide distribution in tenofovir predose concentrations was observed, with values ranging from 17 to 297 ng/mL (coefficient of variation 77%). No significant differences were noted in tenofovir predose concentrations between subjects who were administered PrEP daily (n = 75) or on demand (n = 25) [94 (35-255) versus 104 (37-287) ng/mL; P = 0.476]. Comparable tenofovir predose concentrations were found between patients with HIV infection (n = 220) who were administered branded TDF and those without HIV infection who were treated with 5 different generic TDF-based formulations with generics-to-branded ratios. These were always within the range of 80%-125% and were used to define bioequivalence. CONCLUSIONS: The marketed generic formulations of TDF delivered tenofovir plasma predose concentrations comparable with those delivered by branded formulations.


Asunto(s)
Fármacos Anti-VIH/sangre , Medicamentos Genéricos/metabolismo , Tenofovir/sangre , Adulto , Fármacos Anti-VIH/uso terapéutico , Femenino , Infecciones por VIH/sangre , Infecciones por VIH/tratamiento farmacológico , Humanos , Masculino , Profilaxis Pre-Exposición/métodos , Estudios Retrospectivos , Tenofovir/uso terapéutico
6.
Heart Surg Forum ; 23(3): E343-E349, 2020 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-32524971

RESUMEN

BACKGROUND: Out-of-center extracorporeal membrane oxygenation (ECMO) and extracorporeal life support (ECLS) implantation for the treatment of acute cardiorespiratory failure with subsequent transport to a tertiary care center has been introduced successfully into the medical practice. However, due to the very specific and resource intensive nature of this therapeutic concept, it seems important to generate algorithms for adequate patient selection. The aim of our study was to analyze the impact of patients' gender on early clinical outcome in this specific therapeutic scenario. METHODS: Ninety-seven consecutive patients treated by out-of-center ECMO/ECLS implantation and subsequent transport and treatment in our tertiary care cardiovascular center within the Hallesche Extracorporeal Life Support Program (HELP) retrospectively were analyzed, regarding the impact of patients' gender on early clinical outcome. RESULTS: Mechanical circulatory support successfully was weaned in two-thirds of the male patients. This result was achieved in only one-third of the female patients (59.4% in male vs. 33.3% in female, P = .0267). Overall survival significantly was higher in the male group (62.5% in male versus 30.3% in female, P = .0052). In uni- and multivariate logistic regression analysis, female gender was an independent predictor of in-hospital mortality (uni: OR:3.833, CI:1.597-9.745, P = .0034; multi: OR:3.477, CI:1.146-11.494, P = .0322). Worse outcome also was associated with following independent predictors, age, SOFA score, lactate and ventilation time pre-ECMO/ECLS implantation. CONCLUSION: The current study demonstrates a worse early survival for women, following emergent out-of- center ECMO/ECLS implantation and subsequent transport and treatment in our tertiary care cardiovascular center. Gender should be included in patient selection algorithms while basic research approaches are needed to better understand the mechanisms underlying these gender- specific outcome disparities.


Asunto(s)
Circulación Extracorporea/efectos adversos , Oxigenación por Membrana Extracorpórea/efectos adversos , Insuficiencia Cardíaca/terapia , Medición de Riesgo/métodos , Adulto , Anciano , Femenino , Alemania/epidemiología , Insuficiencia Cardíaca/mortalidad , Mortalidad Hospitalaria/tendencias , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Distribución por Sexo , Factores Sexuales , Tasa de Supervivencia/tendencias
7.
Catheter Cardiovasc Interv ; 94(5): 755-763, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-30790414

RESUMEN

OBJECTIVES: To identify prevalence/impact of previous implantation of cardiac electronic devices (CEDs), such as cardioverter defibrillator (ICD) and cardiac resynchronization (CRT), in a group of MitraClip (MC) candidates with LVEF < 30%. BACKGROUND: MC therapy is nowadays often considered in patients with depressed left ventricular ejection fraction (LVEF%) and symptomatic severe secondary MR. METHODS: Data from the German Transcatheter Mitral Valve Interventions (TRAMIs) registry were analyzed. Patients with pre-procedural LVEF <30% were selected and divided according to the presence of CEDs. Pre-procedural, peri-procedural, and 1-year follow-up data were analyzed. RESULTS: Out of 689 MC patients, 235 had LVEF<30%. Of these, 23% (54/235) had CRT, 36.6% (86/235) ICD, and 40.4% (95/235) had no CEDs. Risk profile was similar (median STS score CRT 6.0 (IQR: 3.0-12.0); ICD 7.0 (IQR: 4.0-12.0); No-CED 6.5 (IQR: 2.0-10.0); p = 0.8). No procedural mortality was observed and hospital mortality was 5.6% in CRT, 2.3% in ICD, and 3.2% in No-CED (p = 0.5). At discharge, severe MV regurgitation was reported in 3.8% of CRT, 3.7% of ICD, and 1.1% of No-CED (p = 0.9). One year estimated survival (CRT 75.7%; ICD 75.8%; No-CED 78%; p = 0.94) and freedom from MACCE (CRT 73.6%; ICD 75.8%; No-CED 74.5%; p = 0.88) were similar. CONCLUSIONS: A third of patients have been already submitted to CEDs implantation at time of referral for MC therapy and 40% of those with severely depressed LVEF% arrive to MC therapy before ICD/CRT implantation. The presence of CED does not impair acute MC therapy success. Mid-term follow-up outcomes are similar in patients with and without CEDs.


Asunto(s)
Cateterismo Cardíaco , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/mortalidad , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Alemania , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Recuperación de la Función , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/mortalidad , Disfunción Ventricular Izquierda/fisiopatología
8.
BMC Infect Dis ; 19(1): 881, 2019 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-31640581

RESUMEN

BACKGROUND: Bendamustine, used for the treatment of indolent B-cell non-Hodgkin lymphoma and chronic lymphocytic leukemia, is known to cause prolonged myelosuppression and lymphocytopenia and has been associated with the risk of developing serious and fatal infections. While reports of localized CMV infections in asymptomatic patients exist, disseminated CMV disease has not been described. CASE PRESENTATION: We report the first case of disseminated CMV infection in a 75-year-old male diagnosed with lymphoplasmacytic lymphoma/Waldenström macroglobulinemia with massive bone marrow infiltration. Despite 6-cycle R-bendamustine chemotherapy resulted in a good partial response, the patient developed persistent fever and severe weight loss. Analysis of cerebrospinal fluid and peripheral blood revealed the presence of CMV-DNA, while the fundus oculi examination revealed bilateral CMV retinitis. Treatment with induction and maintenance drugs was complicated by neutropenia and deterioration of renal function with electrolyte imbalance. From an immunological standpoint, we observed a profound imbalances in phenotype and function of B- and T-cell subsets, with a high proportion of circulating total, activated CD69+ and CD80+ B-cells, a low γ/δ T-cell frequency with a high proportion of CD69- and CD38-expressing cells, and hyperactivated/exhausted CD4+ and CD8+ T-cell phenotypes unable to face CMV challenge. CONCLUSIONS: We hereby describe a severe form of disseminated CMV disease after R-bendamustine treatment. Our observations strongly support the careful clinical monitoring of CMV reactivation/infection in oncologic patients undergoing this therapeutic regimen.


Asunto(s)
Clorhidrato de Bendamustina/efectos adversos , Infecciones por Citomegalovirus/inducido químicamente , Anciano , Antineoplásicos Alquilantes/efectos adversos , Antivirales/uso terapéutico , Linfocitos B/efectos de los fármacos , Linfocitos B/inmunología , Linfocitos T CD8-positivos/inmunología , Infecciones por Citomegalovirus/tratamiento farmacológico , Infecciones por Citomegalovirus/inmunología , Retinitis por Citomegalovirus/inducido químicamente , Retinitis por Citomegalovirus/tratamiento farmacológico , Retinitis por Citomegalovirus/inmunología , Humanos , Masculino , Subgrupos de Linfocitos T/efectos de los fármacos , Subgrupos de Linfocitos T/inmunología , Valganciclovir/uso terapéutico , Macroglobulinemia de Waldenström/tratamiento farmacológico
9.
Heart Vessels ; 34(12): 1969-1975, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31134380

RESUMEN

The objectives of the study were to evaluate the impact of aortic angulation (AA) on success of transcatheter aortic valve replacement (TAVR) with a new generation self-expandable prosthesis (Medtronic Evolut R®). Specific anatomical conditions, such as for example the presence of a horizontal aorta with elevated AA, have seemed to pose a significant challenge for the correct positioning and consequent functioning of self-expandable TAVR prostheses. We assessed 146 patients treated with Evolut R. AA was measured at computed tomography and two groups were identified using as cutoff the mean AA value. Acute outcomes were collected and compared. AA mean value was 49.6 ± 9.4° (AA ≥ 50°: 76 and AA < 50°: 70 patients). Risk profile (Logistic euroSCORE: AA ≥ 50°: 15.7; 75% IQR: 11.1-22.1 vs. AA < 50°: 14.7; 75% IQR: 10.7-24.0; p = 0.8) was equivalent. Perioperative results were similar: valve resheathing (AA ≥ 50°: 21.0% vs. AA < 50°: 24.2%; p = 0.6), recapturing (AA ≥ 50°: 19.7% vs. AA < 50°: 25.7%; p = 0.3), fluoroscopy time (AA ≥ 50°: 11.1 IQR: 8.6-17.0 min. vs. AA < 50°: 11.0 IQR: 8.0-15.7 min.; p = 0.9), and contrast agent use (AA ≥ 50°: 99.0 ± 41.8 ml. vs. AA < 50°: 104.2 ± 38.5 ml.; p = 0.4). At discharge, moderate paravalvular leak was present in 8/76 (10.5%) of the AA ≥ 50° and 6/70 (8.6%) of the AA < 50° (p = 0.7) patients. Severe paravalvular leak, implantation of a second valve, and/or conversion to surgery did not occur. Early safety (AA ≥ 50°: 7.8% vs. AA < 50°: 5.7%; p = 0.6) was similar in the two groups. AA did not affect procedural outcomes and valve performance of the Evolut R prosthesis.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Aorta Torácica/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Masculino , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
10.
Heart Surg Forum ; 22(2): E134-E139, 2019 03 11.
Artículo en Inglés | MEDLINE | ID: mdl-31013224

RESUMEN

BACKGROUND: We present our initial institutional experience with transaortic (TAo) transcatheter aortic valve implantation (TAVI) using a self-expanding aortic bioprosthesis. METHODS: A total of 106 patients underwent TAo TAVI with Medtronic CoreValve through a small partial upper sternotomy. We focus our analysis on the overall perioperative results, procedural learning curve (first 30 patients), and midterm follow-up outcomes. RESULTS: VARC-2 device success was achieved in 95 patients (89%), and there were no intraoperative deaths. Nine patients (8.4%) required a second valve and conversion to standard surgery was required in 2 patients (1.8%). The final aortic insufficiency was grade 0 in 65 patients (62%) and grade 1 in 39 (37%). Although patients treated in the TAo TAVI learning phase required a significantly longer radiation time and contrast agent use, device success (93.4% versus 88.2%, P = .7) and prostheses hemodynamics were similar. All-cause mortality at 30 days was 12% (13/106). At a median follow-up of 392 days (IQR: 216-494 days) estimated overall 1-year survival was 72%. No significant differences were reported in terms of 30-day and 1-year observed mortality, and estimated 1-year survival in the learning and later phase of TAo TAVI. CONCLUSION: TAo TAVI can be performed safely even in the very early phase of the learning curve. Although satisfactory results can be achieved from the beginning, a significant reduction in contrast agent use and radiological exposure are expected as the technique is mastered. Good hemodynamics have been documented and should be further improved with modifications achieved in the TAVI self-expandable valves technology.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Curva de Aprendizaje , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/mortalidad , Femenino , Alemania , Humanos , Masculino , Esternotomía , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad
11.
Pacing Clin Electrophysiol ; 41(2): 128-135, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29222869

RESUMEN

OBJECTIVES: The study aim is to present the long-term performance of a new generation implantable cardioverter defibrillator (ICD) electrode with floating atrial dipole (Linox S DX, Biotronik, Berlin, Germany). BACKGROUND: The single ICD electrode with a floating dipole in the atrial chamber was introduced about 15 years ago to overcome risk of inappropriate shock. METHODS: After implantation, internal electrocardiogram data were prospectively collected via telemonitoring (Home Monitoring, Biotronik). RESULTS: A total of 93 patients (81.5% male, 18.5% female; 58.9 ± 12.3 years) were implanted with a single-chamber ICD using the Linox S DX. Patients were followed up for a median of 693 days (33-2,460 days). At time of implantation average p-wave value was 3.5 ± 1.7 mV and remained stable throughout follow-up with an average value of 3.7 ± 1 mV (P = 0.2). A total of 460 arrhythmic episodes were recorded and 185 (40.2%) were incorrectly stratified by the device software. Seven patients (7.5%) experienced inappropriate ICD therapy. In three patients, VT episodes were not detected and remained untreated. CONCLUSIONS: Although the Linox S DX lead presents a satisfactory long-term stability of the atrial sensing, many of the messages sent to the device during follow-up were incorrectly classified by the ICD software. As a result, inappropriate therapy occurred with a rate similar to that observed with dual-chamber ICDs, but some malignant arrhythmias remained undiagnosed and untreated while occurring. Results in larger prospective cohorts should be analyzed and software improvements of the device should be suggested to overcome these potential drawbacks.


Asunto(s)
Desfibriladores Implantables/tendencias , Electrodos Implantados , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Programas Informáticos , Resultado del Tratamiento
12.
Heart Vessels ; 33(2): 205-211, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28808788

RESUMEN

Prediction of follow-up shock is crucial to stratify patients with dilated cardiomyopathy (DCM) requiring implantable cardioverter defibrillator (ICD). The objective of the article is to assess the predictive value of endo-myocardial biopsy (EMB) towards ICD shock and follow-up mortality. A series of patients with DCM scheduled for ICD implantation underwent EMB to further determine the genesis of DCM. Presence of fibrosis and inflammation was documented and related to outcomes. A total of 240 patients were referred for ICD as primary (56%) and secondary (44%) prophylaxis. EMB showed myocardial fibrosis in 55.4%, inflammation in 55.7%, and viral genomic material in 60%. Median follow-up was 39 months (1-209). Appropriate and inappropriate shocks occurred in 29.2 and 20.4%. At logistic regression, determinants of appropriate shock were ICD indication for secondary prophylaxis (direct relationship: p = 0.009, OR 3.4, CI 1.3-8.8) and presence of inflammation at EMB (inverse relationship: p = 0.04, OR 0.4, CI 0.1-0.9). Moreover, the sole determinant of inappropriate shock was age at implant (inverse relationship: p = 0.003, OR = 0.9, CI 0.90-0.98). Overall mean estimated survival was 168 months and 5-year survival was 83%. Degree of improvement in LVEF% was the sole determinant of follow-up mortality (inverse relationship p = 0.02; HR = 0.9; CI 0.88-0.99). Present selection criteria for ICDs implant rely mainly on LVEF% that lacks sensitivity and specificity. EMB can identify the substrate of increased or reduced life-threatening arrhythmias. Presence of inflammation is a positive prognostic factor for reduced arrhythmogenic risk, independently by the ICD implantation indication.


Asunto(s)
Biopsia/métodos , Cardiomiopatía Dilatada/terapia , Desfibriladores Implantables , Miocardio/patología , Choque Cardiogénico/etiología , Cardiomiopatía Dilatada/diagnóstico , Ecocardiografía , Femenino , Estudios de Seguimiento , Alemania/epidemiología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/epidemiología , Tasa de Supervivencia/tendencias
13.
Catheter Cardiovasc Interv ; 89(1): 135-142, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27739165

RESUMEN

OBJECTIVES: We present our single center experience with the direct flow medical (DFM) prosthesis addressing the impact of native aortic valve (AV) calcification degree on outcomes. BACKGROUND: The DFM® has been introduced for transcatheter aortic valve implantation (TAVI). The valve has a nonmetallic and inflatable support structure. METHODS: Patients were divided in two groups according to preoperative cardiac computed tomography (CT): group I moderate calcification and group II heavy calcification of the total AV area. We evaluated 118 patients: 53 (45%) group I and 65 (55%) group II. RESULTS: Preoperative trans-AV gradient and calcification extension across the aortic unit were significantly higher in group II (P = 0.008 and P < 0.0001). CT perimeter derived annular diameter (group I 24.7 ± 2.1 mm vs. group II 24.8 ± 1.9; P = 0.6) and implanted prosthesis size (group I 26.1 ± 1.5 mm vs. group II 25.7 ± 1.5; P = 0.1) were similar. Hemodynamics were similar: mean gradient 16.1 ± 5.9 mm Hg (group I) vs. 17.3 ± 6.5 mm Hg (group II) (P = 0.3). Total aortic regurgitation (AR) was mild in 5.7% in group I and 20% in group II (P = 0.03). None developed moderate/severe AR. Heavy AV calcification was the sole independent determinant for mild regurgitation (P = 0.02; OR = 7; 95% CI: 1.2-37.6). Follow-up (289 days; 40-760 days) estimated survival was 88.1% (group I) and 93.8% (group II) (P = 0.3). CONCLUSIONS: Independent of AV calcification degree, adequate sizing and implantation can be achieved with the DFM®. Although higher burden of calcification increases the rate of mild AR, no patient developed moderate and severe AR. Short-term estimated survival was not influenced by calcification degree. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/patología , Bioprótesis , Calcinosis/terapia , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Calcinosis/diagnóstico por imagen , Calcinosis/mortalidad , Calcinosis/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Distribución de Chi-Cuadrado , Ecocardiografía , Femenino , Alemania , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Análisis Multivariante , Oportunidad Relativa , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
14.
Catheter Cardiovasc Interv ; 89(3): 420-428, 2017 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-27739170

RESUMEN

OBJECTIVES: To analyze our single center experience with the Direct Flow Medical (DFM). BACKGROUND: The DFM has been recently introduced to the market and large real world experiences are lacking. METHODS: A total of 126 patients with severe aortic valve stenosis (AVS) were treated by the same team from March 2013 to May 2015. Device success and procedural safety were classified, according to valve academic research consortium (VARC) criteria, for the entire cohort, including patients treated in the early phases of our learning curve. RESULTS: Clinical and trans-thoracic echocardiography follow-up was performed (median duration 279 days; 36-761 days). Mean age was 80.9 ± 5.5 years and median logistic Euro-SCORE was 15.9 (5.5-84.2). Cardiovascular 30-day mortality was 4.8% (6/126), device success 89.6% (113/126), and early safety 85.7% (108/126). At discharge, no aortic regurgitation (AR) was present in 85.7% and mild AR in 14.3% of the patients. Estimated 1-year follow-up survival was 91%. At follow-up, no AR was present in 87.3%, mild AR in 10.9%, and moderate AR in 1.8%. Mean gradient of 15.1 ± 6.3 mm Hg and prosthesis effective orifice area of 1.6 ± 0.6 cm2 were reported. CONCLUSIONS: In this single center experience, the DFM valve showed satisfactory clinical and hemodynamic results. Short-term follow-up confirmed the consistent clinical results, with low rates of AR and acceptable trans-prosthetic gradients and prosthetic effective orifice area. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/diagnóstico por imagen , Cateterismo Cardíaco/instrumentación , Ecocardiografía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Hemodinámica , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidad , Femenino , Alemania , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Estimación de Kaplan-Meier , Curva de Aprendizaje , Masculino , Selección de Paciente , Valor Predictivo de las Pruebas , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
15.
Catheter Cardiovasc Interv ; 87(3): 500-7, 2016 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-26013307

RESUMEN

OBJECTIVES: We present our experience with an inflatable, non-metallic, fully retrievable, and repositionable transcatheter aortic valve [Direct Flow® Medical (DFM)] focusing on technical features adopted during implantation. BACKGROUND: Implantation techniques of new generation percutaneous aortic valves are still developing and with experience implementations are described. METHODS: The "low pressure" (initial valve inflation at 4 ATM, lower than the recommended 12 ATM) and the "alternate aortic curve" techniques (initial valve pulling either from the wire running on the side of the inner or from the one on the outer aortic curve) are part of our modified protocol for DFM® implantation. RESULTS: Forty-two consecutive patients underwent TAVI with DFM. The "low pressure" technique was used in all patients. In 27 (64.3%) patients the bulkiest calcifications were on the inner aortic curve side, and an inner curve technique was used to initiate valve pulling toward the annular hinge point. In the remaining 15 (35.7%) patients, an outer curve technique was used. Neither pull-through nor re-valving was reported. Valve performance showed mean gradient of 8.9 mm Hg. Mild paravalvular leak was reported in seven (16%) patients. No one experienced moderate or severe aortic insufficiency. Thirty-day mortality was 9.5% (4/42). CONCLUSION: The "low pressure technique" and the "alternate curve technique" guarantee an anatomy and patient tailored approach to achieve controlled and finely tuned valve seating.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/patología , Valvuloplastia con Balón , Calcinosis/terapia , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Aortografía , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/mortalidad , Calcinosis/diagnóstico por imagen , Calcinosis/mortalidad , Calcinosis/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Presión , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento
16.
J Endovasc Ther ; 23(1): 172-81, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26496956

RESUMEN

PURPOSE: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. METHODS: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. RESULTS: The bird-beak configuration with the greatest protrusion extension exhibited the maximum TAG device displacement (1.66 mm), while the lowest protrusion extension configuration led to the minimum amount of both displacement and rotation parameters (0.25 mm and 0.6°, respectively). A positive relationship was found between the infolding parameters and the flow circulating in the aorta and left subclavian artery. Similarly, TAG device displacement was positively and significantly (p<0.05) correlated with the pulse pressure for all bird-beak configurations and device sizes. However, no collapse was observed under chronic perfusion testing maintained for 30 days and pulse pressure of 100 mm Hg. CONCLUSION: These findings suggest that endograft infolding depends primarily on the amount of aortic pulsatility and flow rate and that physiological flows do not necessarily engender hemodynamic loads on the proximal bird-beak segment sufficient to cause TAG collapse. Hemodynamic variables may allow for identification of patients at high risk of endograft infolding and help guide preventive intervention to avert its occurrence.


Asunto(s)
Aorta Torácica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Hemodinámica , Modelos Anatómicos , Modelos Cardiovasculares , Falla de Prótesis , Stents , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/fisiopatología , Aortografía , Procedimientos Endovasculares/efectos adversos , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/etiología , Migración de Cuerpo Extraño/fisiopatología , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/fisiopatología , Humanos , Diseño de Prótesis , Flujo Pulsátil , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
17.
Artif Organs ; 40(4): 394-7, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26517844

RESUMEN

Acute type A retrograde aortic dissection is characterized by a port of entry located in the descending aorta near the subclavian take-off, and is currently treated with surgery. Our experience with two patients who underwent a complicated postoperative course stimulated a review of the current literature and discussion of possible alternative strategies in light of recent advances in endovascular treatment.


Asunto(s)
Aneurisma de la Aorta Torácica/terapia , Disección Aórtica/terapia , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares/métodos , Adulto , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aortografía , Humanos , Masculino , Persona de Mediana Edad , Stents , Resultado del Tratamiento
19.
J Heart Valve Dis ; 24(2): 169-72, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26204679

RESUMEN

A case is reported of iatrogenic mitral valve chordal rupture occurring during transcatheter aortic valve implantation (TAVI) with an inflatable and repositionable valve (Direct Flow; Direct Flow Medical, Santa Rosa, CA, USA). The specific implantation technique requires initial valve advancement into the left ventricular cavity, valve inflation within the ventricular cavity, and a final finely tuned valve upward pulling through the left ventricular outflow tract until contact with the aortic annulus is achieved. During this phase of the procedure, entangling with the mitral subvalvular apparatus should be excluded, to avoid inadvertent tissue tearing and consequent mitral valve malfunction. The present patient underwent TAVI but then developed symptomatic severe mitral valve regurgitation resulting from chordal rupture. The condition was successfully treated percutaneously by implanting a Mitra-Clip.


Asunto(s)
Cuerdas Tendinosas/lesiones , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/etiología , Anciano de 80 o más Años , Válvula Aórtica , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Enfermedad Iatrogénica , Complicaciones Intraoperatorias , Masculino , Rotura
20.
Ann Vasc Surg ; 29(4): 841.e13-7, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25733217

RESUMEN

Whenever some basic rules for endovascular aortic repair of type B aortic dissection are not followed, iatrogenic complications may develop. A 64-year-old gentleman was referred to our institution for revision of previous treatment of complex type B aortic dissection with 2 bare stents. At 3 months, the most proximal aortic bare stent had entered, via the proximal tear, the false lumen. Aortic expansion and dynamic obstruction at the level of the renal arteries had also developed. In a first step, we removed the proximal aortic bare stent surgically. Few days later, 2 covered endografts were implanted into the true lumen of the thoracic aorta with clinical success. The rationale for using endovascular treatment in patients with complicated type B aortic dissection is coverage of the entry tear with covered nonoversized endografts. Negative results are achieved whenever these very simple rules are not strictly followed.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Stents , Disección Aórtica/complicaciones , Disección Aórtica/diagnóstico , Aneurisma de la Aorta Torácica/complicaciones , Aneurisma de la Aorta Torácica/diagnóstico , Aortografía/métodos , Prótesis Vascular , Remoción de Dispositivos , Humanos , Enfermedad Iatrogénica , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Reoperación , Tomografía Computarizada por Rayos X , Resultado del Tratamiento