Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
J Biol Chem ; 299(1): 102768, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36470426

RESUMEN

The KRAS gene is one of the most frequently mutated oncogenes in human cancer and gives rise to two isoforms, KRAS4A and KRAS4B. KRAS post-translational modifications (PTMs) have the potential to influence downstream signaling. However, the relationship between KRAS PTMs and oncogenic mutations remains unclear, and the extent of isoform-specific modification is unknown. Here, we present the first top-down proteomics study evaluating both KRAS4A and KRAS4B, resulting in 39 completely characterized proteoforms across colorectal cancer cell lines and primary tumor samples. We determined which KRAS PTMs are present, along with their relative abundance, and that proteoforms of KRAS4A versus KRAS4B are differentially modified. Moreover, we identified a subset of KRAS4B proteoforms lacking the C185 residue and associated C-terminal PTMs. By confocal microscopy, we confirmed that this truncated GFP-KRAS4BC185∗ proteoform is unable to associate with the plasma membrane, resulting in a decrease in mitogen-activated protein kinase signaling pathway activation. Collectively, our study provides a reference set of functionally distinct KRAS proteoforms and the colorectal cancer contexts in which they are present.


Asunto(s)
Neoplasias Colorrectales , Proteínas Quinasas Activadas por Mitógenos , Proteínas Proto-Oncogénicas p21(ras) , Transducción de Señal , Humanos , Neoplasias Colorrectales/genética , Isoformas de Proteínas/genética , Isoformas de Proteínas/metabolismo , Procesamiento Proteico-Postraduccional , Proteínas Proto-Oncogénicas p21(ras)/genética , Proteínas Proto-Oncogénicas p21(ras)/metabolismo , Línea Celular Tumoral , Proteómica , Proteínas Quinasas Activadas por Mitógenos/metabolismo
2.
J Proteome Res ; 20(1): 317-325, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-33074679

RESUMEN

Identification of proteoforms, the different forms of a protein, is important to understand biological processes. A proteoform family is the set of different proteoforms from the same gene. We previously developed the software program Proteoform Suite, which constructs proteoform families and identifies proteoforms by intact-mass analysis. Here, we have applied this approach to top-down proteomic data acquired at the National High Magnetic Field Laboratory 21 tesla Fourier transform ion cyclotron resonance mass spectrometer (data available on the MassIVE platform with identifier MSV000085978). We explored the ability to construct proteoform families and identify proteoforms from the high mass accuracy data that this instrument provides for a complex cell lysate sample from the MCF-7 human breast cancer cell line. There were 2830 observed experimental proteforms, of which 932 were identified, 44 were ambiguous, and 1854 were unidentified. Of the 932 unique identified proteoforms, 766 were identified by top-down MS2 analysis at 1% false discovery rate (FDR) using TDPortal, and 166 were additional intact-mass identifications (∼4.7% calculated global FDR) made using Proteoform Suite. We recently published a proteoform level schema to represent ambiguity in proteoform identifications. We implemented this proteoform level classification in Proteoform Suite for intact-mass identifications, which enables users to determine the ambiguity levels and sources of ambiguity for each intact-mass proteoform identification.


Asunto(s)
Ciclotrones , Proteómica , Análisis de Fourier , Humanos , Espectrometría de Masas , Programas Informáticos
3.
Anal Chem ; 93(26): 9119-9128, 2021 07 06.
Artículo en Inglés | MEDLINE | ID: mdl-34165955

RESUMEN

Proton-transfer reactions (PTRs) have emerged as a powerful tool for the study of intact proteins. When coupled with m/z-selective kinetic excitation, such as parallel ion parking (PIP), one can exert exquisite control over rates of reaction with a high degree of specificity. This allows one to "concentrate", in the gas phase, nearly all the signals from an intact protein charge state envelope into a single charge state, improving the signal-to-noise ratio (S/N) by 10× or more. While this approach has been previously reported, here we show that implementing these technologies on a 21 T FT-ICR MS provides a tremendous advantage for intact protein analysis. Advanced strategies for performing PTR with PIP were developed to complement this unique instrument, including subjecting all analyte ions entering the mass spectrometer to PTR and PIP. This experiment, which we call "PTR-MS1-PIP", generates a pseudo-MS1 spectrum derived from ions that are exposed to the PTR reagent and PIP waveforms but have not undergone any prior true mass filtering or ion isolation. The result is an extremely rapid and significant improvement in the spectral S/N of intact proteins. This permits the observation of many more proteoforms and reduces ion injection periods for subsequent tandem mass spectrometry characterization. Additionally, the product ion parking waveform has been optimized to enhance the PTR rate without compromise to the parking efficiency. We demonstrate that this process, called "rapid park", can improve reaction rates by 5-10× and explore critical factors discovered to influence this process. Finally, we demonstrate how coupling PTR-MS1 and rapid park provides a 10-fold reduction in ion injection time, improving the rate of tandem MS sequencing.


Asunto(s)
Proteínas , Protones , Indicadores y Reactivos , Iones , Espectrometría de Masas en Tándem
4.
Clin Chem Lab Med ; 59(4): 653-661, 2021 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-33079696

RESUMEN

OBJECTIVES: Multiple myeloma (MM) is a malignant plasma cell neoplasm, requiring the integration of clinical examination, laboratory and radiological investigations for diagnosis. Detection and isotypic identification of the monoclonal protein(s) and measurement of other relevant biomarkers in serum and urine are pivotal analyses. However, occasionally this approach fails to characterize complex protein signatures. Here we describe the development and application of next generation mass spectrometry (MS) techniques, and a novel adaptation of immunofixation, to interrogate non-canonical monoclonal immunoproteins. METHODS: Immunoprecipitation immunofixation (IP-IFE) was performed on a Sebia Hydrasys Scan2. Middle-down de novo sequencing and native MS were performed with multiple instruments (21T FT-ICR, Q Exactive HF, Orbitrap Fusion Lumos, and Orbitrap Eclipse). Post-acquisition data analysis was performed using Xcalibur Qual Browser, ProSight Lite, and TDValidator. RESULTS: We adapted a novel variation of immunofixation electrophoresis (IFE) with an antibody-specific immunosubtraction step, providing insight into the clonal signature of gamma-zone monoclonal immunoglobulin (M-protein) species. We developed and applied advanced mass spectrometric techniques such as middle-down de novo sequencing to attain in-depth characterization of the primary sequence of an M-protein. Quaternary structures of M-proteins were elucidated by native MS, revealing a previously unprecedented non-covalently associated hetero-tetrameric immunoglobulin. CONCLUSIONS: Next generation proteomic solutions offer great potential for characterizing complex protein structures and may eventually replace current electrophoretic approaches for the identification and quantification of M-proteins. They can also contribute to greater understanding of MM pathogenesis, enabling classification of patients into new subtypes, improved risk stratification and the potential to inform decisions on future personalized treatment modalities.


Asunto(s)
Mieloma Múltiple , Proteínas de Mieloma , Proteómica/métodos , Anticuerpos Monoclonales , Humanos , Inmunoelectroforesis , Espectrometría de Masas , Mieloma Múltiple/diagnóstico
5.
J Proteome Res ; 19(9): 3779-3791, 2020 09 04.
Artículo en Inglés | MEDLINE | ID: mdl-32538093

RESUMEN

Prefractionation of complex mixtures of proteins derived from biological samples is indispensable for proteome analysis via top-down mass spectrometry (MS). Polyacrylamide gel electrophoresis (PAGE), which enables high-resolution protein separation based on molecular size, is a widely used technique in biochemical experiments and has the potential to be useful in sample fractionation for top-down MS analysis. However, the lack of a means to efficiently recover the separated proteins in-gel has always been a barrier to its use in sample prefractionation. In this study, we present a novel experimental workflow, called Passively Eluting Proteins from Polyacrylamide gels as Intact species for MS ("PEPPI-MS"), which allows top-down MS of PAGE-separated proteins. The optimization of Coomassie brilliant blue staining followed by the passive extraction step in the PEPPI-MS workflow enabled the efficient recovery of proteins, separated on commercial precast gels, from a wide range of molecular weight regions in under 10 min. Two-dimensional separation combining offline PEPPI-MS with online reversed-phase liquid chromatographic separation resulted in identification of over 1000 proteoforms recovered from the target region of the gel (≤50 kDa). Given the widespread availability and relatively low cost of traditional sodium dodecyl sulfate (SDS)-PAGE equipment, the PEPPI-MS workflow will be a powerful prefractionation strategy for top-down proteomics.


Asunto(s)
Resinas Acrílicas , Electroforesis en Gel de Poliacrilamida , Espectrometría de Masas
6.
Anal Chem ; 92(18): 12193-12200, 2020 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-32812743

RESUMEN

Fourier transform mass spectrometers routinely provide high mass resolution, mass measurement accuracy, and mass spectral dynamic range. In this work, we utilize 21 T Fourier transform ion cyclotron resonance (FT-ICR) to analyze product ions derived from the application of multiple dissociation techniques and/or multiple precursor ions within a single transient acquisition. This ion loading technique, which we call, "chimeric ion loading", saves valuable acquisition time, decreases sample consumption, and improves top-down protein sequence coverage. In the analysis of MCF7 cell lysate, we show collision-induced dissociation (CID) and electron-transfer dissociation (ETD) on each precursor on a liquid chromatography-mass spectrometry (LC-MS) timescale and improve mean sequence coverage dramatically (CID-only 15% vs chimeric 33%), even during discovery-based acquisition. This approach can also be utilized to multiplex the acquisition of product ion spectra of multiple charge states from a single protein precursor or multiple ETD/proton-transfer reactions (PTR) reaction periods. The analytical utility of chimeric ion loading is demonstrated for top-down proteomics, but it is also likely to be impactful for tandem mass spectrometry applications in other areas.


Asunto(s)
Proteínas de Neoplasias/análisis , Proteómica , Análisis de Fourier , Humanos , Células MCF-7 , Espectrometría de Masas en Tándem , Células Tumorales Cultivadas
7.
Anal Chem ; 92(4): 3213-3219, 2020 02 18.
Artículo en Inglés | MEDLINE | ID: mdl-32011122

RESUMEN

Stored waveform inverse Fourier transform (SWIFT) is a versatile method to generate complex isolation/ejection waveforms for precursor isolation prior to tandem mass spectrometry experiments. Here, we report ultrahigh resolving power ion isolation by SWIFT on a 21 T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. Individual histone proteoforms are isolated (0.6 m/z isolation window) with near 100% efficiency using a 52 ms SWIFT isolation, followed by in-cell fragmentation by ultraviolet photodissociation (UVPD). Ion isolation resolving power of 175 000 (m/Δm) is demonstrated by isolation of individual peaks at a spacing of 0.0034 Da at m/z 597 from a complex mixture of Canadian bitumen. An individual m/z ion, which corresponds to a single elemental composition, from a complex mixture is isolated and fragmented by infrared multiphoton dissociation (IRMPD). Theoretical and experimental considerations that limit achievable ion isolation resolving power are discussed.


Asunto(s)
Ciclotrones , Análisis de Fourier , Espectrometría de Masas/instrumentación , Secuencia de Aminoácidos , Histonas , Proteómica , Relación Señal-Ruido
8.
Proteomics ; 19(10): e1800361, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-31050378

RESUMEN

A proteoform is a defined form of a protein derived from a given gene with a specific amino acid sequence and localized post-translational modifications. In top-down proteomic analyses, proteoforms are identified and quantified through mass spectrometric analysis of intact proteins. Recent technological developments have enabled comprehensive proteoform analyses in complex samples, and an increasing number of laboratories are adopting top-down proteomic workflows. In this review, some recent advances are outlined and current challenges and future directions for the field are discussed.


Asunto(s)
Aminoácidos/análisis , Espectrometría de Masas , Procesamiento Proteico-Postraduccional , Proteoma/análisis , Proteómica/métodos , Animales , Biología Computacional , Electroforesis Capilar , Humanos , Lenguajes de Programación , Reproducibilidad de los Resultados , Programas Informáticos
9.
Anal Chem ; 91(5): 3263-3269, 2019 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-30801187

RESUMEN

The current five-year survival rate for systemic AL amyloidosis or multiple myeloma is ∼51%, indicating the urgent need for better diagnosis methods and treatment plans. Here, we describe highly specific and sensitive top-down and middle-down MS/MS methods owning the advantages of fast sample preparation, ultrahigh mass accuracy, and extensive residue cleavages with 21 telsa FT-ICR MS/MS. Unlike genomic testing, which requires bone marrow aspiration and may fail to identify all monoclonal immunoglobulins produced by the body, the present method requires only a blood draw. In addition, circulating monoclonal immunoglobulins spanning the entire population are analyzed and reflect the selection of germline sequence by B cells. The monoclonal immunoglobulin light chain FR2-CDR2-FR3 was sequenced by database-aided de novo MS/MS and 100% matched the gene sequencing result, except for two amino acids with isomeric counterparts, enabling accurate germline sequence classification. The monoclonal immunoglobulin heavy chains were also classified into specific germline sequences based on the present method. This work represents the first application of top/middle-down MS/MS sequencing of endogenous human monoclonal immunoglobulins with polyclonal immunoglobulins background.


Asunto(s)
Amiloidosis/clasificación , Cadenas Ligeras de Inmunoglobulina/sangre , Mieloma Múltiple/clasificación , Espectrometría de Masas en Tándem/métodos , Secuencia de Aminoácidos , Amiloidosis/diagnóstico , Anticuerpos Monoclonales/análisis , Anticuerpos Monoclonales/metabolismo , Cromatografía Líquida de Alta Presión , Análisis de Fourier , Humanos , Cadenas Ligeras de Inmunoglobulina/química , Inmunoglobulinas/aislamiento & purificación , Inmunoglobulinas/metabolismo , Mieloma Múltiple/diagnóstico , Paraproteinemias/clasificación , Paraproteinemias/diagnóstico
10.
Clin Chem ; 65(8): 986-994, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31040099

RESUMEN

BACKGROUND: Hemoglobinopathies and thalassemias are the most common genetically determined disorders. Current screening methods include cation-exchange HPLC and electrophoresis, the results of which can be ambiguous because of limited resolving power. Subsequently, laborious genetic testing is required for confirmation. METHODS: We performed a top-down tandem mass spectrometry (MS/MS) approach with a fast data acquisition (3 min), ultrahigh mass accuracy, and extensive residue cleavage by use of positive electrospray ionization 21 Tesla Fourier transform ion cyclotron resonance-tandem mass spectrometry (21 T FT-ICR MS/MS) for hemoglobin (Hb) variant de novo sequencing and ß-thalassemia diagnosis. RESULTS: We correctly identified all Hb variants in blind analysis of 18 samples, including the first characterization of homozygous Hb Himeji variant. In addition, an Hb heterozygous variant with isotopologue mass spacing as small as 0.0194 Da (Hb AD) was resolved in both precursor ion mass spectrum (MS1) and product ion mass spectrum (MS2). In blind analysis, we also observed that the abundance ratio between intact δ and ß subunits (δ/ß) or the abundance ratio between intact δ and α subunits (δ/α) could serve to diagnose ß-thalassemia trait caused by a mutation in 1 HBB gene. CONCLUSIONS: We found that 21 T FT-ICR MS/MS provides a benchmark for top-down MS/MS analysis of blood Hb. The present method has the potential to be translated to lower resolving power mass spectrometers (lower field FT-ICR mass spectrometry and Orbitrap) for Hb variant analysis (by MS1 and MS2) and ß-thalassemia diagnosis (MS1).


Asunto(s)
Análisis de Fourier , Hemoglobinopatías/sangre , Hemoglobinas/química , Espectrometría de Masas/métodos , Espectrometría de Masas en Tándem/métodos , Talasemia beta/sangre , Secuencia de Aminoácidos , Ciclotrones , Variación Genética , Hemoglobinopatías/genética , Humanos , Sensibilidad y Especificidad , Análisis de Secuencia de Proteína/métodos , Globinas alfa/química , Globinas beta/química , Talasemia beta/genética , Globinas delta/química
11.
Mol Cell Proteomics ; 15(3): 975-88, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26785730

RESUMEN

Histones represent a class of proteins ideally suited to analyses by top-down mass spectrometry due to their relatively small size, the high electron transfer dissociation-compatible charge states they exhibit, and the potential to gain valuable information concerning combinatorial post-translational modifications and variants. We recently described new methods in mass spectrometry for the acquisition of high-quality MS/MS spectra of intact proteins (Anderson, L. C., English, A. M., Wang, W., Bai, D. L., Shabanowitz, J., and Hunt, D. F. (2015) Int. J. Mass Spectrom. 377, 617-624). Here, we report an extension of these techniques. Sequential ion/ion reactions carried out in a modified Orbitrap Velos Pro/Elite(TM) capable of multiple fragment ion fills of the C-trap, in combination with data-dependent and targeted HPLC-MS experiments, were used to obtain high resolution MS/MS spectra of histones from butyrate-treated HeLa cells. These spectra were used to identify several unique intact histone proteoforms with up to 81% sequence coverage. We also demonstrate that parallel ion parking during ion/ion proton transfer reactions can be used to separate species of overlapping m/z that are not separated chromatographically, revealing previously indiscernible signals. Finally, we characterized several truncated forms of H2A and H2B found within the histone fractions analyzed, achieving up to 93% sequence coverage by electron transfer dissociation MS/MS. Results of follow-up in vitro experiments suggest that some of the truncated histone H2A proteoforms we observed can be generated by cathepsin L, an enzyme known to also catalyze clipping of histone H3.


Asunto(s)
Histonas/metabolismo , Proteoma/análisis , Espectrometría de Masa por Ionización de Electrospray/instrumentación , Butiratos/química , Variación Genética , Células HeLa , Histonas/genética , Humanos , Procesamiento Proteico-Postraduccional
12.
J Proteome Res ; 16(2): 1087-1096, 2017 02 03.
Artículo en Inglés | MEDLINE | ID: mdl-27936753

RESUMEN

Successful high-throughput characterization of intact proteins from complex biological samples by mass spectrometry requires instrumentation capable of high mass resolving power, mass accuracy, sensitivity, and spectral acquisition rate. These limitations often necessitate the performance of hundreds of LC-MS/MS experiments to obtain reasonable coverage of the targeted proteome, which is still typically limited to molecular weights below 30 kDa. The National High Magnetic Field Laboratory (NHMFL) recently installed a 21 T FT-ICR mass spectrometer, which is part of the NHMFL FT-ICR User Facility and available to all qualified users. Here we demonstrate top-down LC-21 T FT-ICR MS/MS of intact proteins derived from human colorectal cancer cell lysate. We identified a combined total of 684 unique protein entries observed as 3238 unique proteoforms at a 1% false discovery rate, based on rapid, data-dependent acquisition of collision-induced and electron-transfer dissociation tandem mass spectra from just 40 LC-MS/MS experiments. Our identifications included 372 proteoforms with molecular weights over 30 kDa detected at isotopic resolution, which substantially extends the accessible mass range for high-throughput top-down LC-MS/MS.


Asunto(s)
Neoplasias Colorrectales/química , Espectrometría de Masas/métodos , Proteínas de Neoplasias/análisis , Proteoma/análisis , Proteómica/métodos , Secuencia de Aminoácidos , Neoplasias Colorrectales/patología , Mezclas Complejas/química , Ciclotrones/instrumentación , Análisis de Fourier , Humanos , Espectrometría de Masas/instrumentación , Proteómica/instrumentación
14.
Int J Mass Spectrom ; 377: 617-624, 2015 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-25844056

RESUMEN

Previously, we described implementation of a front-end ETD (electron transfer dissociation) source for an Orbitrap instrument (1). This source facilitates multiple fills of the C-trap with product ions from ETD of intact proteins prior to mass analysis. The result is a dramatic enhancement of the observed ion current without the need for time consuming averaging of data from multiple mass measurements. Here we show that ion-ion proton transfer (IIPT) reactions can be used to simplify ETD spectra and to disperse fragment ions over the entire mass range in a controlled manner. We also show that protein derivatization can be employed to selectively enhance the sequence information observed at the N- and C-termini of a protein.

15.
Anal Chem ; 85(17): 8385-90, 2013 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-23909443

RESUMEN

Electron transfer dissociation (ETD), a technique that provides efficient fragmentation while depositing little energy into vibrational modes, has been widely integrated into proteomics workflows. Current implementations of this technique, as well as other ion-ion reactions like proton transfer, involve sophisticated hardware, lack robustness, and place severe design limitations on the instruments to which they are attached. Described herein is a novel, electrical discharge-based reagent ion source that is located in the first differentially pumped region of the mass spectrometer. The reagent source was found to produce intense reagent ion signals over extended periods of time while having no measurable impact on precursor ion signal. Further, the source is simple to construct and enables implementation of ETD on any instrument without modification to footprint. Finally, in the context of hybrid mass spectrometers, relocation of the reagent ion source to the front of the mass spectrometer enables new approaches to gas phase interrogation of intact proteins.


Asunto(s)
Transporte de Electrón , Espectrometría de Masa por Ionización de Electrospray/métodos , Iones
16.
J Mass Spectrom Adv Clin Lab ; 28: 20-26, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36814695

RESUMEN

ß-thalassemia is a quantitative hemoglobin (Hb) disorder resulting in reduced production of Hb A and increased levels of Hb A2. Diagnosis of ß-thalassemia can be problematic when combined with other structural Hb variants, so that the separation approaches in routine clinical centers are not sufficiently decisive to obtain accurate results. Here, we separate the intact Hb subunits by high-performance liquid chromatography, followed by top-down tandem mass spectrometry of intact subunits to distinguish Hb variants. Proton transfer reaction-parallel ion parking (PTR-PIP), in which a radical anion removes protons from multiply charged precursor ions and produces charge-reduced ions spanning a limited m/z range, was used to increase the signal-to-noise ratio of the subunits of interest. We demonstrate that the δ/ß ratio can act as a biomarker to identify ß-thalassemia in normal electrospray ionization MS1 and PTR-PIP MS1. The application of PTR-PIP significantly increases the sensitivity and specificity of the HPLC-MS method to identify δ/ß ratio as a thalassemia biomarker.

17.
J Am Soc Mass Spectrom ; 34(2): 137-144, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36656140

RESUMEN

Protein mass measurement by mass spectrometry is complicated by wide isotopic distributions that result from incorporation of heavy isotopes of C, H, N, O, and S, thereby limiting signal-to-noise ratio (SNR) and accurate intact mass determination, particularly for larger proteins [Fenselau et al. Anal. Chem. 1983, 55 (2), 353-356]. Observation of the monoisotopic mass-to-charge ratio (m/z) is the simplest and most accurate way to determine intact protein mass, but as mass increases, the relative abundance of the monoisotopic peak becomes so low that it is often undetectable. Here, we used an isotopically depleted growth medium to culture bacterial cells (Escherichia coli), resulting in isotopically depleted proteins. Isotopically depleted proteins show increased sequence coverage, mass measurement accuracy, and increased S/N of the monoisotopic peak by Fourier transform ion cyclotron resonance mass spectrometry analysis. We then grew Caenorhabditis elegans cells in a medium containing living isotopically depleted E. coli cells, thereby producing the first isotopically depleted eukaryotic proteins. This is the first time isotopic depletion has been implemented for four isotopes (1H, 12C, 14N, and 16O), resulting in the highest degree of depletion ever used for protein analysis and further improving MS analysis.


Asunto(s)
Caenorhabditis elegans , Escherichia coli , Animales , Escherichia coli/química , Análisis de Fourier , Ciclotrones , Proteínas/química , Espectrometría de Masas/métodos , Isótopos , Cromatografía Liquida/métodos , Línea Celular
18.
Biochemistry ; 51(30): 5942-50, 2012 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-22769851

RESUMEN

N-Terminal methylation of free α-amino groups is a post-translational modification of proteins that was first described 30 years ago but has been studied very little. In this modification, the initiating M residue is cleaved and the exposed α-amino group is mono-, di-, or trimethylated by NRMT, a recently identified N-terminal methyltransferase. Currently, all known eukaryotic α-amino-methylated proteins have a unique N-terminal motif, M-X-P-K, where X is A, P, or S. NRMT can also methylate artificial substrates in vitro in which X is G, F, Y, C, M, K, R, N, Q, or H. Methylation efficiencies of N-terminal amino acids are variable with respect to the identity of X. Here we use in vitro peptide methylation assays and substrate immunoprecipitations to show that the canonical M-X-P-K methylation motif is not the only one recognized by NRMT. We predict that N-terminal methylation is a widespread post-translational modification and that there is interplay between N-terminal acetylation and N-terminal methylation. We also use isothermal calorimetry experiments to demonstrate that NRMT can efficiently recognize and bind to its fully methylated products.


Asunto(s)
Metiltransferasas/química , Metiltransferasas/metabolismo , Humanos , Metilación , Metiltransferasas/genética , Fragmentos de Péptidos/genética , Fragmentos de Péptidos/metabolismo , Unión Proteica/genética , Procesamiento Proteico-Postraduccional/genética , Especificidad por Sustrato/genética
19.
J Am Soc Mass Spectrom ; 33(1): 123-130, 2022 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-34955023

RESUMEN

Hemoglobinopathies are one of the most prevalent genetic disorders, affecting millions throughout the world. These are caused by pathogenic variants in genes that control the production of hemoglobin (Hb) subunits. As the number of known Hb variants has increased, it has become more challenging to obtain unambiguous results from routine chromatographic assays employed in the clinical laboratory. Top-down proteomic analysis of Hb by mass spectrometry is a definitive method to directly characterize the sequences of intact subunits. Here, we apply "chimeric ion loading" to characterize Hb ß subunit variants. In this technique, product ions derived from complementary dissociation techniques are accumulated in a multipole storage device before delivery to a 21 T Fourier-transform ion cyclotron resonance mass spectrometer for simultaneous detection. To further improve the efficiency of identification of Hb variants and localization of the mutation site(s), we developed an R programming script, "Variants Identifier", to search top-down data against a database containing accurate intact mass differences and diagnostic ions from investigated Hb variants. A second R script, "PredictDiag", was developed and employed to determine relevant diagnostic ions for additional Hb variants with known sequences. These two R scripts were successfully applied to the identification of a Hb δ-ß fusion protein and other Hb variants. The combination of chimeric ion loading and the above R scripts enables rapid and reliable interpretation of top-down mass spectrometry data, regardless of activation type, for Hb variant identification.


Asunto(s)
Hemoglobinas/análisis , Hemoglobinas/química , Proteómica/métodos , Espectrometría de Masas en Tándem/métodos , Humanos , Análisis de Secuencia de Proteína/métodos , Programas Informáticos , Espectroscopía Infrarroja por Transformada de Fourier
20.
Science ; 375(6579): 411-418, 2022 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-35084980

RESUMEN

Human biology is tightly linked to proteins, yet most measurements do not precisely determine alternatively spliced sequences or posttranslational modifications. Here, we present the primary structures of ~30,000 unique proteoforms, nearly 10 times more than in previous studies, expressed from 1690 human genes across 21 cell types and plasma from human blood and bone marrow. The results, compiled in the Blood Proteoform Atlas (BPA), indicate that proteoforms better describe protein-level biology and are more specific indicators of differentiation than their corresponding proteins, which are more broadly expressed across cell types. We demonstrate the potential for clinical application, by interrogating the BPA in the context of liver transplantation and identifying cell and proteoform signatures that distinguish normal graft function from acute rejection and other causes of graft dysfunction.


Asunto(s)
Células Sanguíneas/química , Proteínas Sanguíneas/química , Células de la Médula Ósea/química , Bases de Datos de Proteínas , Isoformas de Proteínas/química , Proteoma/química , Empalme Alternativo , Linfocitos B/química , Proteínas Sanguíneas/genética , Linaje de la Célula , Humanos , Leucocitos Mononucleares/química , Trasplante de Hígado , Plasma/química , Isoformas de Proteínas/genética , Procesamiento Proteico-Postraduccional , Proteómica , Linfocitos T/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA