Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Vasc Interv Radiol ; 35(2): 226-231, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37797742

RESUMEN

PURPOSE: To assess the effectiveness and safety of cryoablation (CRA) for the treatment of recurrent or oligometastatic solid tumors located in the thoracoabdominal soft tissues. MATERIALS AND METHODS: Twenty-two percutaneous CRA procedures performed in 19 patients to treat recurrent or oligometastatic tumors in thoracoabdominal soft tissue were retrospectively examined. All procedures were performed between January 2015 and June 2021 under ultrasound and computed tomography (CT) guidance, and the most complex procedures were performed with CT-based navigation systems. The histology of the primary tumors included colorectal adenocarcinoma, squamous cell lung carcinoma, pancreatic adenocarcinoma, renal cell carcinoma, and hepatocellular carcinoma. Adverse events, technical success, and local tumor control were analyzed. RESULTS: The mean age of the patients was 66.5 years, with a mean tumor size of 24.8 mm. The mean time of the procedures was 68 minutes, with a mean number of 2.5 cryoprobes used. Hydrodissection was performed in 63% of the procedures to protect the surrounding anatomical structures. The mean size of the ice ball, measured on axial CT scans at the end of the procedures, was 43.5 mm. No severe adverse events were observed. Technical success was achieved in all cases. Three patients experienced local tumor progression (2 residual disease and 1 recurrence), which were successfully treated with a second CRA procedure. CONCLUSIONS: Percutaneous CRA is a safe and effective therapy in selected cases of recurrent or oligometastatic tumors in the thoracoabdominal soft tissues.


Asunto(s)
Adenocarcinoma , Criocirugía , Neoplasias Renales , Neoplasias Hepáticas , Neoplasias Pulmonares , Neoplasias Pancreáticas , Humanos , Anciano , Resultado del Tratamiento , Criocirugía/efectos adversos , Criocirugía/métodos , Adenocarcinoma/cirugía , Estudios Retrospectivos , Neoplasias Pancreáticas/cirugía , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/cirugía , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/etiología , Neoplasias Pulmonares/cirugía
2.
Int J Hyperthermia ; 40(1): 2163309, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36599421

RESUMEN

BACKGROUND: sequential or simultaneous applications of multiple antennas have been proposed to create larger ablation zone; however, there is a lack of data in patients affected by liver tumors, with potentially different results from animal liver models. The purpose of this study was to evaluate efficacy and safety of liver percutaneous microwave ablation using simultaneous activation of two antennas to treat lesions bigger than 2,5 cm; particularly the focus was assessing whether the ratio of ablation zone volume in millimeters to applied energy in kilojoules [R(AZ:E)] differs between hepatocellular carcinoma in a cirrhotic liver and liver metastasis and if it is correlated to complications incidence or recurrence of disease. METHODS: Fifty-five liver microwave ablation performed with two simultaneous antennas from March 2017 to June 2021 were retrospectively reviewed; 9 procedures were excluded due to the association with Chemoembolization. Size, shape, volume of lesions and ablation zones were recorded. Technical success was defined as complete devascularization of the treated area at the post-procedural CT. R(AZ:E) was determined dividing the ablation zone volume in mm3 by the amount of energy in kilojoules applied in each procedure and complications were reported. RESULTS: Technical success was achieved in all the procedures. Mean R(AZ:E) was 0,75 ± 0,58. T-student test for patients with HCC and patients with metastasis about R(AZ:E) was significant (p = 0.03). The incidence of bilomas was lower for HCC (p = 0.022). One-month follow-up showed Complete Response (CR) in 44/46 (95,6%) patients; Three-six months follow-up demonstrated: CR in 43/46 (93.5%) cases and 12 months follow-up highlighted CR in 40/45 (88,9%) cases. CONCLUSIONS: These results provide preliminary evidence of efficacy and safety of simultaneous liver MWA using two antennas, highlighting the importance of procedural indications.


Asunto(s)
Carcinoma Hepatocelular , Ablación por Catéter , Neoplasias Hepáticas , Animales , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/patología , Microondas/uso terapéutico , Estudios Retrospectivos , Resultado del Tratamiento , Ablación por Catéter/métodos
3.
Radiol Med ; 127(7): 714-724, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35701683

RESUMEN

PURPOSE: To evaluate efficacy and safety of radiofrequency ablation (RFA) and microwave ablation (MWA) in unresectable lung malignancies. METHODS: Data regarding patients with primary and secondary lung tumors treated with RFA or MWA from 2008 to 2020 were reviewed retrospectively. Primary study objectives such as technical success, primary and secondary technique efficacy rates, local tumor progression (LTP) rate, LPT-free survival (LPTFS) and overall survival (OS) were assessed. Secondary study objectives were side effects and complications. RFA and MWA were compared using the Chi-square test for continuous variables. Kaplan-Meier curves were calculated for survival statistical analysis. RESULTS: A total of 113 patients with primary or secondary lung tumor underwent 74 RFA (48%) and 81 MWA (52%). Technical success rate was 151/155 (97%); primary and secondary technique efficacy rates were 123/155 (79%) and 129/155 (83%), respectively. During the entire study follow-up, 32 cases experienced disease progression (20%), of which 18 underwent repeat ablation (12%), in 6 cases with success (4%). Residual unablated tumor happened in 4/155 cases (3%). LTP occurred in 28/155 cases (17%). The only factor associated with poorer LTP-FS was lesion diameter ≥ 30 mm (P < 0.05). One-, 3- and 5-years LTP-FS was 83%, 82%, 82%, respectively. One-, 3- and 5-years OS of the entire population was 87%, 74%, 73%, respectively. Minor and major complication rates were 53/155 (34%) and 29/155 (19%), respectively. CONCLUSIONS: In conclusion, this study confirms the appropriateness of RFA and MWA for lung tumors treatment, in terms of safety and efficacy.


Asunto(s)
Técnicas de Ablación , Ablación por Catéter , Neoplasias Hepáticas , Neoplasias Pulmonares , Ablación por Catéter/métodos , Humanos , Neoplasias Hepáticas/patología , Neoplasias Pulmonares/cirugía , Microondas/uso terapéutico , Estudios Retrospectivos , Resultado del Tratamiento
5.
Radiol Case Rep ; 18(1): 145-149, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36340226

RESUMEN

We present the case of a 50-year-old woman affected by a rectal gastrointestinal stromal tumor (GIST), with a recurrence in pre-sacral and pre-coccygeal space after surgery and Imatinib therapy. GISTs are the most common mesenchymal tumors of the gastrointestinal tract and rectal GISTs are rare (only 2% of cases); magnetic resonance and computed tomography are the main imaging techniques for diagnosis and follow-up, while ultrasound and contrast-enhanced ultrasound may be useful to perform a percutaneous biopsy, as in the case presented: the imaging features of the lesion in all these imaging methods are displayed.

6.
Interv Neuroradiol ; : 15910199231205045, 2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-37832136

RESUMEN

Mechanical thrombectomy is a standard treatment for acute stroke, but it can be technically challenging in elderly patients with difficult vascular anatomy. To overcome this issue, we propose a new endovascular approach called the "tightrope" technique. This technique uses a stiff guidewire and a standard angiographic catheter to straighten the internal carotid artery (ICA) tortuosity, allowing the guiding catheter to be positioned next to the intracranial level. We retrospectively evaluated all the procedures in which the "tightrope" technique was used. This approach involves advancing a 0.035″ Advantage stiff guidewire and a standard 4 Fr angiographic catheter through the vascular tortuosity. The catheter is twisted over the guide wire in a clockwise direction, gaining tension that gradually straightens the vascular axis, allowing the guiding catheter to pass up to the distal ICA. Between June 2022 and March 2023, we successfully performed consecutive mechanical thrombectomy procedures using the tightrope technique in 11 patients with highly tortuous ICA segments. In all cases, we were able to safely advance the catheter system up to the distal cervical ICA. Although our study included a small cohort of patients, the "tightrope" technique proved to be successful in all patients, allowing for safe advancement of the guiding catheter toward extremely tortuous anatomy. However, further validation in a larger patient population is necessary to determine the technique's effectiveness and safety profile.

7.
Radiol Case Rep ; 17(9): 2996-2999, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35747740

RESUMEN

Several cases of cancer patients with 18-fluorodeoxyglucose (18FDG) Positron Emission Tomography/Computed Tomography (PET/CT) evidence of metabolically active axillary lymph nodes after COVID-19 vaccination have been described, creating a diagnostic dilemma and sometimes leading to further unnecessary examinations. A 62-year-old male, diagnosed with prostate cancer, treated with hormone-therapy and radiotherapy of the prostate 2 years before, underwent fluorine-18 choline (F-FCH) PET/CT for restaging purpose, less than 3 weeks after he had received the second dose of the Pfizer BioNTech-BNT162b2 mRNA COVID-19 vaccine. This exam showed an increased F-FCH uptake and an enlargement of the left axillary, paratracheal, para-aortic, subcarinal, and hilar bilateral lymph nodes. Fourteen weeks later, the patient underwent a new F-FCH PET-CT scan, displaying an almost complete regularization of the FCH uptake in all the previously involved regions. The patient was not treated after the first PET-CT scan, thus, the aforementioned PET/CT findings represented inflammatory vaccine-related lymph nodes. This case highlights the significance of knowing vaccination history to correctly interpret imaging findings and to avoid false-positive reports.

8.
J Thorac Dis ; 14(2): 247-256, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35280488

RESUMEN

Background: Augmented reality navigation system for percutaneous computed tomography (CT)-guided pulmonary biopsies has recently been introduced. There are no studies in literature about its use for ground glass lesions biopsies. The aim of this study is to evaluate the effectiveness of an augmented reality infrared navigation system performance on CT-guided percutaneous lung ground glass opacity (GGO) biopsy compared to a standard CT-guided technique. Methods: A total of 80 patients with lung GGO who underwent to a percutaneous CT-guided lung biopsy with an augmented reality infrared navigation system were retrospectively enrolled in the study. Comparison was performed with a group of 80 patients who underwent to lung biopsy with the standard CT-guided technique. Evaluation of maximum lesion diameter (MLD), distance between lesion and pleural surface (DPS), distance travelled by the needle (DTP), procedural time, validity of histological sample, procedural complications and the radiation dose to the patient's chest were recorded for each patient of both groups. In addition, each group was divided into two subgroups based on lesion size, according to a cut-off of 1.5 cm (<1.5 cm; ≥1.5 cm). Results: Augmented reality navigation system showed a significant reduction in procedural time, radiation dose administrated to patients and complications rate compared to a standard CT-guided technique. Technical success was achieved in the 100% of cases in both groups, but the diagnostical success was higher in the group where patients underwent to lung biopsies with the use of navigation system. We also found that using an augmented reality navigation system increases the diagnostical success rate for lesion <1.5 cm. MLD, DPS and DTP did not differ significantly between the two groups of patients. Conclusions: The use of an augmented reality navigation system for percutaneous CT-guided pulmonary GGO biopsies has demonstrated a lower incidence of post-procedural complications, a significantly reduction of the radiation dose administered to patients and a higher diagnostical success rate.

9.
J Kidney Cancer VHL ; 8(4): 32-37, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34722129

RESUMEN

Development of more sensitive imaging techniques has caused an increase in the number of diagnosed small renal tumors. Approximately 2-3% of these lesions are proved to be angiomyolipomas (AML), a rare benign tumor of the kidney sometimes causing pain and hematuria. The most required approach is observation, but in the case of recurrent symptoms or larger tumors, which may cause bleeding, a more active treatment is required. We present two cases of symptomatic AML tumors of different sizes in the kidney: one treated with transarterial embolization (TAE), and the other with percutaneous cryoablation (CRA). The lesions were diagnosed on the basis of contrast-enhanced computed tomography (CT) scan and magnetic resonance imaging (MRI). Both treatments proved to be effective and safe for treating renal AMLs. A follow-up carried out, based on contrast-enhanced CT scan, confirmed complete treatment of AML and decreased lesion size. There are myriad minimally invasive approaches for the treatment of renal AMLs, and the preservation of renal function remains a priority. The most popular treatment option is the selective renal artery embolization. Owing to its limited invasiveness, CRA could be an attractive option for the preventive treatment of AML.

10.
Curr Oncol ; 28(3): 1751-1760, 2021 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-34066651

RESUMEN

(1) Background: The purpose of this study is to evaluate the impact of an augmented reality navigation system (SIRIO) for percutaneous biopsies and ablative treatments on bone lesions, compared to a standard CT-guided technique. (2) Methods: Bioptic and ablative procedures on bone lesions were retrospectively analyzed. All procedures were divided into SIRIO and Non-SIRIO groups and in <2 cm and >2 cm groups. Number of CT-scans, procedural time and patient's radiation dose were reported for each group. Diagnostic accuracy was obtained for bioptic procedures. (3) Results: One-hundred-ninety-three procedures were evaluated: 142 biopsies and 51 ablations. Seventy-four biopsy procedures were performed using SIRIO and 68 under standard CT-guidance; 27 ablative procedures were performed using SIRIO and 24 under standard CT-guidance. A statistically significant reduction in the number of CT-scans, procedural time and radiation dose was observed for percutaneous procedures performed using SIRIO, in both <2 cm and >2 cm groups. The greatest difference in all variables examined was found for procedures performed on lesions <2 cm. Higher diagnostic accuracy was found for all SIRIO-assisted biopsies. No major or minor complications occurred in any procedures. (4) Conclusions: The use of SIRIO significantly reduces the number of CT-scans, procedural time and patient's radiation dose in CT-guided percutaneous bone procedures, particularly for lesions <2 cm. An improvement in diagnostic accuracy was also achieved in SIRIO-assisted biopsies.


Asunto(s)
Realidad Aumentada , Carbidopa , Combinación de Medicamentos , Humanos , Biopsia Guiada por Imagen , Levodopa/análogos & derivados , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
11.
Biology (Basel) ; 10(7)2021 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-34356501

RESUMEN

(1) Background: The aim of this retrospective study is to assess safety and efficacy of lung radiofrequency (RFA) and microwave ablation (MWA) using an augmented reality computed tomography (CT) navigation system (SIRIO) and to compare it with the standard CT-guided technique. (2) Methods: Lung RFA and MWA were performed with an augmented reality CT 3D navigation system (SIRIO) in 52 patients. A comparison was then performed with a group of 49 patients undergoing the standard CT-guided technique. All the procedures were divided into four groups based on the lesion diameter (>2 cm or ≤2 cm), and procedural time, the number of CT scans, radiation dose administered, and complications rate were evaluated. Technical success was defined as the presence of a "ground glass" area completely covering the target lesion at the immediate post-procedural CT. (3) Results: Full technical success was achieved in all treated malignant lesions for all the considered groups. SIRIO-guided lung thermo-ablations (LTA) displayed a significant decrease in the number of CT scans, procedure time, and patients' radiation exposure (p < 0.001). This also resulted in a dosage reduction in hypnotics and opioids administrated for sedation during LTA. No significant differences were observed between the SIRIO and non-SIRIO group in terms of complications incidence. (4) Conclusions: SIRIO is an efficient tool to perform CT-guided LTA, displaying a significant reduction (p < 0.001) in the number of required CT scans, procedure time, and patients' radiation exposure.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA