Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
BMC Cardiovasc Disord ; 23(1): 8, 2023 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-36624380

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) is recommended to treat paroxysmal and persistent atrial fibrillation (AF). This analysis aimed to assess the hospital efficiency of single-shot cryoballoon ablation (CBA) and point-by-point radiofrequency ablation (RFA). METHODS: The discrete event simulation used PVI procedure times from the FREEZE Cohort study to establish the electrophysiology (EP) lab occupancy time. 1000 EP lab days were simulated according to an illustrative German hospital, including 3 PVI cases per day using CBA at one site and RFA at the other. RESULTS: The analysis included 1560 CBA patients and 1344 RFA patients from the FREEZE Cohort. Some baseline patients' characteristics were different between groups (age, AF type, and some concomitant diseases), without being statistically associated to ablation procedure time. Mean procedure time was 122.2 ± 39.4 min for CBA and 160.3 ± 53.5 min for RFA (p < 0.0001). RFA was associated with a more than five-fold increase of cumulative overtime compared to CBA over the simulated period (1285 h with RFA and 253 h with CBA). 70.7% of RFA lab days included overtime versus 25.7% for CBA. CBA was associated with more days with an additional hour at the end of the EP lab shift compared to RFA (47.8% vs 11.5% days with one hour left, respectively). CONCLUSION: CBA is faster and more predictable than point-by-point RFA, and enables improvements in EP lab efficiency, including: fewer cumulative overtime hours, more days where overtime is avoided and more days with remaining time for the staff or for any EP lab usage. Clinical trial registration NCT01360008 (first registration 25/05/2011).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Estudios de Cohortes , Criocirugía/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Electrofisiología , Resultado del Tratamiento , Recurrencia
2.
J Cardiovasc Electrophysiol ; 33(3): 483-492, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35028995

RESUMEN

BACKGROUND: Registry data add important information to randomized controlled trials (RCT) on real-life aspects of implantable cardioverter-defibrillator (ICD) patients with and without cardiac resynchronization therapy (CRT-D). This analysis of the prospectively conducted German Device Registry aims at comparing mortality rates, comorbidities, complication rates to results from RCT. METHODS: The German Device registry (DEVICE) prospectively collected data on ICD and CRT-D first implantations from 50 German centres. Demographic data, details on cardiac disease, electrocardiogram (ECG), medication, and data about procedure, complications, and hospital stay were stored in electronic case report forms. One year after device implantation patients were contacted for follow-up. RESULTS: DEVICE included n = 4384 first ICD/CRT-D implantations (29.3% CRT-D devices). We found a strong adherence to guidelines with over 90% of patients being on ß-blocker and ACE-inhibitor medication and adequate QRS width in the majority of CRT-D patients. Patients receiving a CRT-D were older (67.6 ± 11.0 years vs. 63.9 ± 13.4 years, p < .001) and had lower ejection fractions (mean 25% vs. 30%, p < .001) compared to ICD patients. Dilated cardiomyopathy was the predominant underlying heart disease in CRT-D (53.3%), coronary artery disease in ICD patients (64.7%). Compared to RCT our DEVICE patients had more comorbidities (17.9% chronic kidney disease [CKD]) and higher 1-year mortality rates (10.7% ICD group, 12.3% CRT group). In multivariate analysis, CKD patients had an almost 2-fold higher risk of 1-year mortality. CONCLUSION: Despite relevant limitations of registry data, DEVICE highlights important differences between RCT and real-world registry data and the impact of comorbidities on mortality of ICD and CRT-D recipients.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Dispositivos de Terapia de Resincronización Cardíaca , Desfibriladores Implantables/efectos adversos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Humanos , Ensayos Clínicos Controlados Aleatorios como Asunto , Sistema de Registros , Resultado del Tratamiento
3.
N Engl J Med ; 378(5): 417-427, 2018 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-29385358

RESUMEN

BACKGROUND: Mortality and morbidity are higher among patients with atrial fibrillation and heart failure than among those with heart failure alone. Catheter ablation for atrial fibrillation has been proposed as a means of improving outcomes among patients with heart failure who are otherwise receiving appropriate treatment. METHODS: We randomly assigned patients with symptomatic paroxysmal or persistent atrial fibrillation who did not have a response to antiarrhythmic drugs, had unacceptable side effects, or were unwilling to take these drugs to undergo either catheter ablation (179 patients) or medical therapy (rate or rhythm control) (184 patients) for atrial fibrillation in addition to guidelines-based therapy for heart failure. All the patients had New York Heart Association class II, III, or IV heart failure, a left ventricular ejection fraction of 35% or less, and an implanted defibrillator. The primary end point was a composite of death from any cause or hospitalization for worsening heart failure. RESULTS: After a median follow-up of 37.8 months, the primary composite end point occurred in significantly fewer patients in the ablation group than in the medical-therapy group (51 patients [28.5%] vs. 82 patients [44.6%]; hazard ratio, 0.62; 95% confidence interval [CI], 0.43 to 0.87; P=0.007). Significantly fewer patients in the ablation group died from any cause (24 [13.4%] vs. 46 [25.0%]; hazard ratio, 0.53; 95% CI, 0.32 to 0.86; P=0.01), were hospitalized for worsening heart failure (37 [20.7%] vs. 66 [35.9%]; hazard ratio, 0.56; 95% CI, 0.37 to 0.83; P=0.004), or died from cardiovascular causes (20 [11.2%] vs. 41 [22.3%]; hazard ratio, 0.49; 95% CI, 0.29 to 0.84; P=0.009). CONCLUSIONS: Catheter ablation for atrial fibrillation in patients with heart failure was associated with a significantly lower rate of a composite end point of death from any cause or hospitalization for worsening heart failure than was medical therapy. (Funded by Biotronik; CASTLE-AF ClinicalTrials.gov number, NCT00643188 .).


Asunto(s)
Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Ablación por Catéter , Insuficiencia Cardíaca/complicaciones , Anciano , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/mortalidad , Ablación por Catéter/efectos adversos , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Frecuencia Cardíaca/efectos de los fármacos , Hospitalización/estadística & datos numéricos , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Función Ventricular Izquierda , Prueba de Paso
4.
J Cardiovasc Electrophysiol ; 32(7): 1833-1841, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33955108

RESUMEN

BACKGROUND: The impact of basic atrial rhythm (sinus rhythm [SR] vs. atrial fibrillation [AF]) during AF ablation on efficacy and safety is unknown. METHODS: About 3375 patients from the German Ablation Registry undergoing first-time AF ablation were divided according to the type of AF and the basic atrial rhythm during the ablation procedure: paroxysmal AF (PAF) and SR [group Ia], PAF and AF [group Ib]), persistent AF and SR (IIa), and persistent AF and AF (IIb). RESULTS: Patients in SR (n = 2312 [67%]) underwent cryoballoon ablation more often (Ia vs. Ib p = .002 and IIa vs. IIb p = .010, whereas in patients in AF (n = 1063 [33%]) radiofrequency (RF)-based ablation (Ia vs. Ib p = .006 and IIa vs. IIb p = .014) including left and/or right atrial substrate modification was more frequently performed. Depending on the basic rhythm there was no difference regarding arrhythmia recurrence during long-term follow-up. For patients suffering from persistent AF acute procedure-related complications were more often documented when ablated in AF (9.1% vs. 4.6%, p = .012). which was mainly driven by the higher occurrence of pericardial effusion/tamponade. For patients suffering from persistent AF, favorable results were found regarding 366-day Kaplan-Meier estimates of the incidence of MACCE (death, myocardial infarction, and stroke; p = .011) and the composite endpoint of death, myocardial infarction, stroke, and major bleeding (p = .006), when ablated in SR. CONCLUSION: Basic atrial rhythm at the time of AF ablation did not affect long-term rhythm outcome. For patients suffering from persistent AF a more favorable acute and long-term safety profile was observed when ablated in SR.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Atrios Cardíacos , Humanos , Recurrencia , Sistema de Registros , Resultado del Tratamiento
5.
Europace ; 21(9): 1313-1324, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-31199860

RESUMEN

AIMS: To evaluate the effectiveness and safety of cryoballoon ablation (CBA) compared with radiofrequency ablation (RFA) for symptomatic paroxysmal or drug-refractory persistent atrial fibrillation (AF). METHODS AND RESULTS: Prospective cluster cohort study in experienced CBA and RFA centres. Primary endpoint was 'atrial arrhythmia recurrence', secondary endpoints were as follows: procedural results, safety, and clinical course. A total of 4189 patients were included: CBA 2329 (55.6%) and RFA 1860 (44.4%). Cryoballoon ablation population was younger, with fewer comorbidities. Procedure time was longer in the RFA group (P = 0.01). Radiation exposure was 2487 (CBA) and 1792 cGycm2 (RFA) (P < 0.001). Follow-up duration was 441 (CBA) and 511 days (RFA) (P < 0.0001). Primary endpoint occurred in 30.7% (CBA) and 39.4% patients (RFA) [adjusted hazard ratio (adjHR) 0.85, 95% confidence interval (CI) 0.70-1.04; P = 0.12). In paroxysmal AF, CBA resulted in a lower risk of recurrence (adjHR 0.80, 95% CI 0.64-0.99; P = 0.047). In persistent AF, the primary outcome was not different between groups. Major adverse cardiovascular and cerebrovascular event rates were 1.0% (CBA) and 2.8% (RFA) (adjHR 0.53, 95% CI 0.26-1.10; P = 0.088). Re-ablations (adjHR 0.46, 95% CI 0.34-0.61; P < 0.0001) and adverse events during follow-up (adjHR 0.64, 95% CI 0.48-0.88; P = 0.005) were less common after CBA. Higher rehospitalization rates with RFA were caused by re-ablations. CONCLUSIONS: The primary endpoint did not differ between CBA and RFA. Cryoballoon ablation was completed rapidly; the radiation exposure was greater. Rehospitalization due to re-ablations and adverse events during follow-up were observed significantly less frequently after CBA than after RFA. Subgroup analysis suggested a lower risk of recurrence after CBA in paroxysmal AF. TRIAL REGISTRATION: ClinicalTrials.gov (NCT01360008), https://clinicaltrials.gov/ct2/show/NCT01360008.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía/métodos , Anciano , Fibrilación Atrial/fisiopatología , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Readmisión del Paciente , Complicaciones Posoperatorias/epidemiología , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Dosis de Radiación , Recurrencia , Reoperación , Resultado del Tratamiento
6.
Heart Vessels ; 34(7): 1196-1202, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30607538

RESUMEN

According to current guidelines prophylactic implantable cardioverter-defibrillator (ICD) therapy is recommended in patients with significantly impaired left ventricular systolic function. However, the recently published DANISH trial did not find a significantly lower long-term rate of death from any cause compared with usual clinical care in patients with non-ischemic cardiomyopathy. We investigated whether registry data from a multi-center 'real-life' registry on patients with non-ischemic cardiomyopathy are similar to this trial. The German Device Registry (DEVICE) is a nationwide, prospective registry with one-year follow-up investigating 5451 patients receiving device implantations in 50 German centers. The present analysis of DEVICE focused on patients with non-ischemic cardiomyopathy and a left ventricular ejection fraction ≤35% who received a prophylactic ICD. Out of 779 patients with symptomatic heart failure and nonischemic cardiomyopathy, 33.1% received a single chamber ICD (VVI), while 11.0% were implanted with a dual-chamber ICD (DDD), and 55.8% received a defibrillator system for cardiac resynchronization therapy. Median follow-up was 16.1 months. 90.7% were alive at follow-up, 9.3% had died during this period. Overall mortality after one year was 5.4%. Overall mortality one year after implantation was significantly increased in patients 68 years and older(7.9%) as compared to younger patients (59-68 years: 2.5%; < 59 years: 3.8%; p < 0.015). Data from the present registry support the recently published results of the DANISH trial. In particular the influence of an increased age as proven in the DANISH trial might also play a role in the present collective. This limits the potential beneficial effect of ICD therapy in particular in the elderly population.


Asunto(s)
Terapia de Resincronización Cardíaca/efectos adversos , Cardiomiopatías/terapia , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Anciano , Cardiomiopatías/mortalidad , Causas de Muerte , Femenino , Alemania/epidemiología , Insuficiencia Cardíaca , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Números Necesarios a Tratar , Estudios Prospectivos , Calidad de Vida , Ensayos Clínicos Controlados Aleatorios como Asunto , Sistema de Registros , Tasa de Supervivencia
8.
Eur Heart J ; 38(17): 1317-1326, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28329395

RESUMEN

AIMS: To analyse outcomes of supraventricular tachycardia (SVT) ablations performed within a prospective German Ablation Quality Registry. METHODS AND RESULTS: Data from 12 566 patients who underwent catheter ablation of SVT between January 2007 and January 2010 to treat atrial fibrillation (AFIB, 37.2% of procedures), atrial flutter (AFL, 29.9%), atrioventricular nodal re-entrant tachycardia (AVNRT, 23.2%), atrioventricular re-entrant tachycardia (6.3%), and focal atrial tachycardia (AT, 3.4%) were prospectively collected. Patients were followed for at least 1 year. The periprocedural success rate was 96.3%, ranging from 84.3% (focal AT) to 98.9% (AVNRT). Kaplan-Meier mortality estimate at 1 year was 1.4% overall, and as high as 2.6% in the AFL group and 2.8% in the focal AT group. Recurrence of ablated or another symptomatic SVT was observed in 3783 (32.6%) of patients, ranging from 17.2% (AVNRT) to 45.6% (AFIB). Repeat ablation was performed in 12.0% of patients. After 1 year, 74.1% of survivors perceived ablation therapy as successful, 15.7% as partly successful, and 9.6% as unsuccessful. Even in those patients with arrhythmia recurrence, 76.0% perceived ablation as successful or partly successful and 89.6% would still undergo repeat ablation in the same institution. CONCLUSION: Ablation therapy for SVT is a safe procedure bringing symptomatic improvement and satisfaction to three quarters of patients after 1 year. Even in patients with arrhythmia recurrence, a high satisfaction level and adherence to the ablating institution could be documented. Strikingly high mortality and stroke rates in follow-up were observed in AFL patients, who apparently need consistent long-term anticoagulation and more medical attention.


Asunto(s)
Ablación por Catéter/psicología , Satisfacción del Paciente , Taquicardia Supraventricular/cirugía , Anciano , Fibrilación Atrial/mortalidad , Fibrilación Atrial/psicología , Fibrilación Atrial/cirugía , Aleteo Atrial/mortalidad , Aleteo Atrial/psicología , Aleteo Atrial/cirugía , Ablación por Catéter/mortalidad , Femenino , Estudios de Seguimiento , Alemania/epidemiología , Mortalidad Hospitalaria , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Recurrencia , Sistema de Registros , Taquicardia por Reentrada en el Nodo Atrioventricular/mortalidad , Taquicardia por Reentrada en el Nodo Atrioventricular/psicología , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Taquicardia Supraventricular/mortalidad , Taquicardia Supraventricular/psicología , Resultado del Tratamiento
9.
J Cardiovasc Electrophysiol ; 28(3): 258-265, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27925337

RESUMEN

INTRODUCTION: Despite a rising demand for catheter ablation (CA) of atrial fibrillation (AF) in an elderly population, complication and success rates are not fully elucidated. We sought to compare complication rates of CA of AF in patients ≥75 versus <75 years of age. METHODS AND RESULTS: Patients with symptomatic, drug-refractory AF were prospectively enrolled from January 2007 to 2010 in this multicenter study. A total of 4,449 patients, group 1 ≥75 years and group 2 <75 years (n = 227, age 77.3 ± 2.2 vs. 59.7 ± 9.8 years, 52.0% vs. n = 4,222, 68.9% male, CHA2 DS2 -VASc-Score 3.7 ± 1.0 vs. 1.7 ± 1.2; P < 0.001, respectively), with paroxysmal AF (59.9% in group 1 vs. 63.3% in group 2, P = 0.30), and persistent AF (34.8% in group 1 vs. 29.4% in group 2, P = 0.082) underwent CA of AF. A centralized follow-up was obtained in 4,347 patients by the Institute for Myocardial Infarction Research (IHF, Ludwigshafen). There was a significant difference between periprocedural stroke rates in the elderly versus the younger cohort (1.3% vs. 0.1%, P < 0.01). In-hospital severe nonfatal complications did not differ significantly between the groups (4.4% vs. 2.7%, P = 0.14). Other procedure-related, in-hospital complications were not significantly different. After a mean follow-up of 472 ± 99 days (group 1) and 477 ± 94 days (group 2), no differences were found in complication rates. CONCLUSION: CA of AF in patients ≥75 years is associated with higher in-hospital stroke rates. In a 1-year follow-up, complication rates do not differ between the groups.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía , Accidente Cerebrovascular/etiología , Potenciales de Acción , Factores de Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Supervivencia sin Enfermedad , Femenino , Alemania , Frecuencia Cardíaca , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
10.
Europace ; 19(6): 968-975, 2017 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-27353325

RESUMEN

AIMS: To analyse the long-term safety of implantable cardioverter defibrillators (ICDs) in patients discharged within 24 h or after 2- 5-day hospitalization, respectively, after complication-free implantation, in circumstances of actual care. METHODS AND RESULTS: Patients in the multicentre, nationwide German DEVICE registry were contacted 12-15 months after their first ICD implantation or device replacement. Data were collected on complications, potential arrhythmic events, syncope, resuscitation, ablation procedures, cardiac events, hospitalizations, heart failure status, change of medication, and quality of life. Of 2356 patients from 43 centres, 527 patients were discharged within 24 h and 1829 were hospitalized routinely for >24 h after complication-free implantations. The disease profiles and rates of co-morbidities were similar at baseline for both cohorts. During between 384 and 543 days of follow-up, there were no significant differences between the groups in terms of complications, hospitalizations, or quality of life. One-year rates of death were 4.5% in patients discharged early compared with 7.2% in hospitalized patients (hazard ratio 0.65; 95% confidence interval 0.42-1.02; P = 0.052). Rates of major adverse cardiovascular events or defibrillator events were not higher in patients discharged after 24 h. In both groups, a high rate of patients declared that they would opt for the procedure again in the same situation. CONCLUSION: Data from a large-scale registry reflecting current day-to-day practice in Germany suggest that most patients can be discharged safely within 24 h of successful ICD implantation if there are no procedure-related events. Follow-up data up to 1.5 years after implantation did not raise long-term safety concerns.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Tiempo de Internación , Alta del Paciente , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Comorbilidad , Supervivencia sin Enfermedad , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Alemania , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Readmisión del Paciente , Seguridad del Paciente , Estudios Prospectivos , Falla de Prótesis , Calidad de Vida , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
11.
J Electrocardiol ; 49(2): 117-23, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26806120

RESUMEN

AIMS: This investigation addresses procedural characteristics of catheter ablation in patients with atrial fibrillation (AF) and sinus bradycardia. METHODS: From the prospective, multi-center German Ablation Registry 1073 patients with sinus rhythm at the time of AF ablation were divided into two groups according to heart rate at start of procedure (A, <60 beats per minute (bpm), n=197; B, 60-99bpm, n=876). RESULTS: Acute procedural success was high (≥98%) and similar between groups. Procedure duration and energy application time were increased in group A (180min vs. 155min and 2561s vs. 1879s, respectively). Major complications were more frequent in group A (2.2% vs. 0.5%), and a greater proportion of these patients was discharged under antiarrhythmic medication (64% vs. 52%). CONCLUSION: Catheter ablation of AF with concomitant sinus bradycardia is associated with high procedural efficacy, longer procedure- and energy application durations, and a slightly elevated complication rate.


Asunto(s)
Fibrilación Atrial/mortalidad , Fibrilación Atrial/cirugía , Bradicardia/mortalidad , Ablación por Catéter/mortalidad , Complicaciones Posoperatorias/mortalidad , Sistema de Registros , Mapeo del Potencial de Superficie Corporal/mortalidad , Mapeo del Potencial de Superficie Corporal/estadística & datos numéricos , Bradicardia/cirugía , Ablación por Catéter/estadística & datos numéricos , Comorbilidad , Femenino , Alemania/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Prevalencia , Estudios Retrospectivos , Factores de Riesgo , Cirugía Asistida por Computador/mortalidad , Cirugía Asistida por Computador/estadística & datos numéricos , Tasa de Supervivencia , Resultado del Tratamiento
12.
J Cardiovasc Electrophysiol ; 25(1): 1-7, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24134539

RESUMEN

BACKGROUND: Catheter ablation is used extensively with curative intention in atrial fibrillation. Radiofrequency ablation has long been a standard of care, while cryoballoon technology has emerged as a feasible approach with promising results. Prospective multicenter registry data referring to both ablation technologies in AF ablation therapy are lacking. METHODS: Between January 2007 and August 2011, a total of 3,775 consecutive patients with symptomatic paroxysmal AF who underwent PV ablation in their respective centers were enrolled. The cohort was divided into 2 groups according to the ablation energy source used: cryoballoon ablation (group 1, n = 905 [24.0%], median age 63 years, 64.3% men) and RF ablation (group 2, n = 2870 [76.0%], median age 63 years, 62.7% men). Comorbidities and baseline clinical characteristics were similar in both groups. RESULTS: Acute success rate was similar in both groups (97.5% in cryo vs 97.6% in RF; P = 0.81). Procedure times were similar, ablation and fluoroscopy times were higher in cryoballoon when compared to RF ablation. Overall complication rate was similar in cryo- (4.6%) and RF-ablation (4.6%; P = 1.0). Phrenic nerve palsy was more often in cryo versus RF ablation (2.1% in cryo vs 0.0% in RF; P < 0.001). Other complications were more common in RF compared to cryoablation (4.6% in RF vs 2.7% in cryo; P < 0.05). CONCLUSION: RF ablation is the most widespread ablation method in Germany, but use of cryoballoon increased significantly. Procedure times were similar, but ablation and fluoroscopy times were longer in cryoballoon ablation. No significant differences were found in terms of acute success and overall complication rate.


Asunto(s)
Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía/métodos , Sistema de Registros , Anciano , Estudios de Cohortes , Femenino , Alemania/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
13.
J Cardiovasc Electrophysiol ; 25(3): 242-9, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24237758

RESUMEN

INTRODUCTION: Catheter ablation (CA) has emerged as a widespread therapeutic option in the treatment of atrial fibrillation (AF). Currently, no safety data with regard to the impact of the underlying structural heart diseases (SHD) are available. We sought to assess the risk for acute and long-term complications during CA of AF in relation to underlying SHD. METHODS AND RESULTS: We included 6,211 patients in a prospective registry undergoing CA of AF in 41 nationwide centers. All patients were divided into 4 groups according to the underlying heart disease: No SHD (69.4%), hypertensive heart disease (HHD) (12.0%), coronary artery disease (CAD) (15.1%), and cardiomyopathy (CM) (3.6%). In univariate analysis, patients with HHD had an overall complication rate of 7.28%, whereas patients without an SHD had a significantly lower rate of 6.01% (P < 0.01). Multivariate analysis revealed that HHD (adjusted odds ratio [OR]: 1.97 [95% confidence interval (CI): 1.02-3.83], P = 0.0442) and age (years; OR: 1.04 [95% CI: 1.01-1.07], P = 0.0155) were independent predictors of severe, nonfatal complications and death. Other SHD including CAD (OR: 1.48 (0.73-3.00), P = 0.2797) and CM (OR: 2.37 [0.70-7.99], P = 0.1630) failed to reach statistical significance. Male sex was protective (OR: 0.47 [95% CI: 0.27-0.81], P = 0.0062). CONCLUSION: In general, CA of AF has a low number of severe complications. In our prospective registry HHD emerged as an independent predictor of severe, nonfatal complications during AF ablation but other SHD including CAD and CM did not. The influence of HHD on the complication rate should be considered in patient selection.


Asunto(s)
Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Complicaciones Posoperatorias/epidemiología , Sistema de Registros , Anciano , Fibrilación Atrial/diagnóstico , Ablación por Catéter/tendencias , Femenino , Estudios de Seguimiento , Alemania/epidemiología , Cardiopatías/epidemiología , Cardiopatías/cirugía , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Estudios Prospectivos , Resultado del Tratamiento
14.
Europace ; 16(4): 595-9, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24406537

RESUMEN

AIMS: The randomized, double-blind Third International Study on Syncope of Uncertain Etiology (ISSUE-3) showed that dual-chamber permanent pacing was effective in reducing the recurrence of syncope in patients ≥ 40 years with severe asystolic, probably neurally mediated syncope (NMS), documented by implantable loop recorder (ILR). Analysis in ISSUE-3 was performed according to the intention-to-treat principle. In the present study, we performed an on-treatment analysis, which included additionally those non-randomized patients followed up in the ISSUE registry to evaluate in a better manner the effectiveness of cardiac pacing therapy. METHODS AND RESULTS: Initially, 504 patients received an ILR, 162 (32%) patients had a diagnosis consistent with NMS within a mean observation period of 15 ± 11 months: 99 (19%) patients had documentation of syncope with ≥ 3 s asystole or ≥ 6 s asystole without syncope. Sixty patients affected by asystolic NMS received cardiac pacing therapy and 86 (33 asystolic and 53 non-asystolic NMS) were untreated; 16 patients were lost to follow-up. Paced and unpaced groups had similar clinical characteristics. During subsequent follow-up, syncope recurred in 10 paced (17%) and in 40 non-paced (46%) patients. At 21 months, the estimated product-limit syncope recurrence rates were 27% [95% confidence interval (CI) 15-47] and 54% (95% CI 43-67), respectively (P = 0.01). With cardiac pacing, the risk of recurrence was reduced by 57% (hazard ratio = 0.43, 95% CI = 0.2-0.8). Complications of pacemaker therapy were haemothorax at implantation in one patient and lead dislodgement that required correction in two patients. CONCLUSION: Permanent cardiac pacing is effective in reducing recurrence of syncope in patients ≥ 40 years with severe asystolic possible NMS with a few complications. The study shows that 61% of patients with a diagnosis of NMS made by ILR received a pacemaker but 5.1 ILRs had to be implanted to find one patient who finally had a pacemaker implanted.


Asunto(s)
Estimulación Cardíaca Artificial , Paro Cardíaco/terapia , Marcapaso Artificial , Síncope/terapia , Anciano , Estimulación Cardíaca Artificial/efectos adversos , Método Doble Ciego , Diseño de Equipo , Paro Cardíaco/diagnóstico , Paro Cardíaco/fisiopatología , Humanos , Análisis de Intención de Tratar , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Recurrencia , Sistema de Registros , Síncope/diagnóstico , Síncope/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
15.
J Thorac Dis ; 16(3): 1825-1835, 2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38617758

RESUMEN

Background: Atrial fibrillation (AF) is a cardiac arrhythmia frequently documented in patients requiring implantable cardioverter defibrillators (ICDs) and/or cardiac resynchronization therapy with defibrillator (CRT-D). Patients with diagnosed AF at the point of ICD or CRT-D implantation may have an impaired follow-up outcome. Methods: The German DEVICE I-II registry is a nationwide prospective multicentre database of patients implanted with ICD and CRT-D with clinical follow-up data. We analysed a 1-year follow up of implanted patients with AF and with sinus rhythm (SR). Results: A total of 4,929 ICD/CRT patients are included in the present analysis: 946 (19.2%) were in AF and 3,983 (80.8%) were SR at time of device implantation. AF patients had a significantly more comorbid profile including older age {72 [interquartile range (IQR), 66-77] vs. 66 (IQR, 56-73) years; P<0.001}, and higher rate of patients with left ventricular ejection fraction <30% (68.2% vs. 61.0%; P<0.001), peripheral artery disease (4.5% vs. 2.7%; P=0.002), diabetes (33.6% vs. 25.5%; P<0.001), hypertension (58.4% vs. 51.1%; P<0.001) and renal failure (22.6% vs. 15.3%; P<0.001). The intra-hospital complication rate was 4.3% in the AF and 3.6% in the SR group (P=0.38). In 1-year follow-up AF patients experienced a significantly higher rate of defibrillator shocks (25% vs. 15.3%; P<0.001). One-year estimated mortality was 10.8% in the AF and 5.9% in the SR group (P<0.001), while estimated 1-year major adverse cardiac and cerebrovascular events (MACCE) rate was 11.2% vs. 7.0% (P<0.001). The effects of AF on electrical shocks and mortality persisted after adjusting for age, sex, advanced New York Heart Association (NYHA) class, severely impaired left ventricular ejection fraction (LVEF), coronary artery disease (CAD), chronic obstructive pulmonary disease (COPD), diabetes mellitus (DM), chronic renal failure (CRF), QRS duration, and type of indication for electronic device implantation. Conclusions: Our clinical data on an extended cohort of contemporary patients confirm the significant impact of AF, and its associated comorbidities, upon mortality and major adverse events after implantation of ICD/CRT.

16.
Circulation ; 125(21): 2566-71, 2012 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-22565936

RESUMEN

BACKGROUND: The efficacy of cardiac pacing for prevention of syncopal recurrences in patients with neurally mediated syncope is controversial. We wanted to determine whether pacing therapy reduces syncopal recurrences in patients with severe asystolic neurally mediated syncope. METHODS AND RESULTS: Double-blind, randomized placebo-controlled study conducted in 29 centers in the Third International Study on Syncope of Uncertain Etiology (ISSUE-3) trial. Patients were ≥40 years, had experienced ≥3 syncopal episodes in the previous 2 years. Initially, 511 patients, received an implantable loop recorder; 89 of these had documentation of syncope with ≥3 s asystole or ≥6 s asystole without syncope within 12 ± 10 months and met criteria for pacemaker implantation; 77 of 89 patients were randomly assigned to dual-chamber pacing with rate drop response or to sensing only. The data were analyzed on intention-to-treat principle. There was syncope recurrence during follow-up in 27 patients, 19 of whom had been assigned to pacemaker OFF and 8 to pacemaker ON. The 2-year estimated syncope recurrence rate was 57% (95% CI, 40-74) with pacemaker OFF and 25% (95% CI, 13-45) with pacemaker ON (log rank: P=0.039 at the threshold of statistical significance of 0.04). The risk of recurrence was reduced by 57% (95% CI, 4-81). Five patients had procedural complications: lead dislodgment in 4 requiring correction and subclavian vein thrombosis in 1 patient. CONCLUSIONS: Dual-chamber permanent pacing is effective in reducing recurrence of syncope in patients ≥40 years with severe asystolic neurally mediated syncope. The observed 32% absolute and 57% relative reduction in syncope recurrence support this invasive treatment for the relatively benign neurally mediated syncope. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00359203.


Asunto(s)
Paro Cardíaco/complicaciones , Marcapaso Artificial , Índice de Severidad de la Enfermedad , Síncope/prevención & control , Anciano , Método Doble Ciego , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Prevención Secundaria , Síncope/epidemiología , Síncope/etiología , Resultado del Tratamiento
17.
Lancet ; 380(9838): 238-46, 2012 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-22713626

RESUMEN

BACKGROUND: Antiarrhythmic drugs prolong the atrial action potential and refractory period, and thereby prevent recurrent atrial fibrillation after cardioversion. The atrial action potential normalises after 2-4 weeks of sinus rhythm, suggesting that antiarrhythmic drugs might not be needed beyond that period. Therefore, we investigated whether short-term antiarrhythmic drug treatment after cardioversion is non-inferior to long-term treatment. METHODS: We enrolled patients in a prospective, randomised, open-label, blinded endpoint assessment trial between May 4, 2007, and March 12, 2010, at 44 centres in Germany. Eligible patients were adults with persistent atrial fibrillation undergoing planned cardioversion. After successful cardioversion, patients were randomly assigned in permuted blocks of six per centre to: no antiarrhythmic drug treatment (control); treatment with flecainide (200-300 mg per day) for 4 weeks (short-term treatment); or flecainide for 6 months (long-term treatment). The primary endpoint was time to persistent atrial fibrillation or death. Patients and clinicians were unmasked to group assignment and treatment. The primary outcome was assessed in a core laboratory, members of which were masked to treatment group. Patients were monitored for 6 months by daily telemetric electrocardiograph (ECG) and centrally adjudicated Holter ECG recordings whenever atrial fibrillation was noted in two consecutive ECGs. Analyses were per protocol. This trial is registered, number ISRCTN62728742. FINDINGS: After assay sensitivity was established with 4-week follow-up data from 242 patients showing that flecainide was superior to no treatment (Kaplan-Meier survival 70·2%vs 52·5%; p=0·0160), the trial continued to compare short-term versus long-term treatment. The primary outcome occurred in 120 (46%) of 261 patients receiving short-term treatment and in 103 (39%) of 263 patients receiving long-term treatment (event-free survival 48·4% [95% CI 41·9-55·0] vs 56·4% [49·1-63·6]; Kaplan-Meier estimate of difference 7·9% [-1·9 to 17·7]; p=0·2081 for non-inferiority; margin prespecified at 12%). In a post-hoc landmark analysis of patients who had not reached the primary endpoint in the first month, long-term treatment was superior to short-term treatment (Kaplan-Meier estimate of difference 14·3% [5·1-23·6]; hazard ratio 0·31 [0·18-0·56]; p=0·0001). INTERPRETATION: Short-term antiarrhythmic drug treatment after cardioversion is less effective than is long-term treatment, but can prevent most recurrences of atrial fibrillation. FUNDING: The German Federal Ministry of Education and Research, Deutsche Forschungsgemeinschaft, 3M Medica, and MEDA Pharmaceuticals.


Asunto(s)
Antiarrítmicos/administración & dosificación , Fibrilación Atrial/tratamiento farmacológico , Flecainida/administración & dosificación , Fibrilación Atrial/terapia , Cardioversión Eléctrica/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
18.
BMJ Open Sport Exerc Med ; 9(3): e001626, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37533594

RESUMEN

Non-communicable diseases (NCDs), including coronary heart disease, stroke, hypertension, type 2 diabetes, dementia, depression and cancers, are on the rise worldwide and are often associated with a lack of physical activity (PA). Globally, the levels of PA among individuals are below WHO recommendations. A lack of PA can increase morbidity and mortality, worsen the quality of life and increase the economic burden on individuals and society. In response to this trend, numerous organisations came together under one umbrella in Hamburg, Germany, in April 2021 and signed the 'Hamburg Declaration'. This represented an international commitment to take all necessary actions to increase PA and improve the health of individuals to entire communities. Individuals and organisations are working together as the 'Global Alliance for the Promotion of Physical Activity' to drive long-term individual and population-wide behaviour change by collaborating with all stakeholders in the community: active hospitals, physical activity specialists, community services and healthcare providers, all achieving sustainable health goals for their patients/clients. The 'Hamburg Declaration' calls on national and international policymakers to take concrete action to promote daily PA and exercise at a population level and in healthcare settings.

19.
N Engl J Med ; 361(15): 1427-36, 2009 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-19812399

RESUMEN

BACKGROUND: The rate of death, including sudden cardiac death, is highest early after a myocardial infarction. Yet current guidelines do not recommend the use of an implantable cardioverter-defibrillator (ICD) within 40 days after a myocardial infarction for the prevention of sudden cardiac death. We tested the hypothesis that patients at increased risk who are treated early with an ICD will live longer than those who receive optimal medical therapy alone. METHODS: This randomized, prospective, open-label, investigator-initiated, multicenter trial registered 62,944 unselected patients with myocardial infarction. Of this total, 898 patients were enrolled 5 to 31 days after the event if they met certain clinical criteria: a reduced left ventricular ejection fraction (< or = 40%) and a heart rate of 90 or more beats per minute on the first available electrocardiogram (ECG) (criterion 1: 602 patients), nonsustained ventricular tachycardia (> or = 150 beats per minute) during Holter monitoring (criterion 2: 208 patients), or both criteria (88 patients). Of the 898 patients, 445 were randomly assigned to treatment with an ICD and 453 to medical therapy alone. RESULTS: During a mean follow-up of 37 months, 233 patients died: 116 patients in the ICD group and 117 patients in the control group. Overall mortality was not reduced in the ICD group (hazard ratio, 1.04; 95% confidence interval [CI], 0.81 to 1.35; P=0.78). There were fewer sudden cardiac deaths in the ICD group than in the control group (27 vs. 60; hazard ratio, 0.55; 95% CI, 0.31 to 1.00; P=0.049), but the number of nonsudden cardiac deaths was higher (68 vs. 39; hazard ratio, 1.92; 95% CI, 1.29 to 2.84; P=0.001). Hazard ratios were similar among the three groups of patients categorized according to the enrollment criteria they met (criterion 1, criterion 2, or both). CONCLUSIONS: Prophylactic ICD therapy did not reduce overall mortality among patients with acute myocardial infarction and clinical features that placed them at increased risk. (ClinicalTrials.gov number, NCT00157768.)


Asunto(s)
Desfibriladores Implantables , Infarto del Miocardio/terapia , Anciano , Causas de Muerte , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/mortalidad , Modelos de Riesgos Proporcionales , Sistema de Registros , Riesgo , Tasa de Supervivencia , Factores de Tiempo
20.
Clin Med Insights Cardiol ; 16: 11795468221116841, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36046182

RESUMEN

Problem: Reducing risk by improving fitness is one of the main objectives of cardiac rehabilitation (CR). To estimate how the number of steps/day post-CR affects coronary patients' prognosis, we analyzed its correlation with the occurrence of death, hospitalizations, and heart complaints, and if and how other variables (ejection fraction (EF), gender, age) relate to those. Methods: One hundred eleven patients (male = 91, female = 20; average age ± standard deviation (SD): 61 ± 11 years) who had been in CR due to recent coronary revascularization or chronic coronary syndrome could be enrolled. Patients were advised to document their steps (daily), blood pressure (daily), weight (weekly) and occurrences of a cardiac event in a diary for 1 year post-CR. A Cox proportional hazard model was used to examine the influence of steps/day, EF, gender, and age until the occurrence of an event. Kaplan-Meier curves were generated to compare patients' profiles. Results: Average steps/day of patients post-CR were 7333 (SD 4426). Increased walking activity reduced risk for cardiac hospitalization (constant steps/day: 5000 vs 7500, hazard rate (HR) reduction of 0.43; 10 000 vs 12 500, HR reduction of 0.20) and risk was higher in patients with an EF < 55% versus EF ⩾ 55% (HR increase of 2.88). Median follow-up time post-CR was 218 days. No patient died, 25 were hospitalized. Discussion: Monitoring the number of steps of coronary patients post CR could be valuable for estimating patients' prognosis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA