Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 227
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Am Heart J ; 269: 15-24, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38042457

RESUMEN

BACKGROUND AND OBJECTIVE: Patients with palpitations clinically suggestive of paroxysmal supraventricular tachycardia (PSVT) are often managed conservatively until ECG-documentation of the tachycardia, leading to high impact on life quality and healthcare resource utilization. We evaluated results of electrophysiological study (EPS), and ablation when appropriate, among these patients, with special focus on gender differences in management. METHODS: BELIEVE SVT is a European multicenter, retrospective registry in tertiary hospitals performing EPS in patients with palpitations, without ECG-documentation of tachycardia or preexcitation, and considered highly suggestive of PSVT by a cardiologist or cardiac electrophysiologist. We analyzed clinical characteristics, results of EPS and ablation, complications, and clinical outcomes during follow-up. RESULTS: Six-hundred eighty patients from 20 centers were included. EPS showed sustained tachycardia in 60.9% of patients, and substrate potentially enabling AVNRT in 14.7%. No major/permanent complications occurred. Minor/transient complications were reported in 0.84% of patients undergoing diagnostic-only EPS and 1.8% when followed by ablation. During a 3.4-year follow-up, 76.2% of patients remained free of palpitations recurrence. Ablation (OR: 0.34, P < .01) and male gender (OR: 0.58, P = .01) predicted no recurrence. Despite a higher female proportion among patients with recurrence, (77.2% vs 63.5% among those asymptomatic during follow-up, P < .01), 73% of women in this study reported no recurrence of palpitations after EPS. CONCLUSIONS: EPS and ablation are safe and effective in preventing recurrence of nondocumented palpitations clinically suggestive of PSVT. Despite a lower efficacy, this strategy is also highly effective among women and warrants no gender differences in management.


Asunto(s)
Ablación por Catéter , Taquicardia Paroxística , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Masculino , Femenino , Estudios Retrospectivos , Carga Sintomática , Taquicardia Paroxística/diagnóstico , Arritmias Cardíacas/cirugía , Sistema de Registros
2.
Environ Geochem Health ; 45(8): 6323-6351, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37301778

RESUMEN

Chlorpyrifos (CPF) is one of the most commonly used organophosphate pesticides. Because CPF was described as a toxic compound without safe levels of exposure for children, certain countries in Latin America and the European Union have banned or restricted its use; however, in Mexico it is used very frequently. The aim of this study was to describe the current situation of CPF in Mexico, as well as its use, commercialization, and presence in soil, water, and aquatic organisms in an agricultural region of Mexico. Structured questionnaires were applied to pesticide retailers to determine the sales pattern of CPF (ethyl and methyl); in addition, monthly censuses were conducted with empty pesticide containers to assess the CPF pattern of use. Furthermore, samples of soil (48 samples), water (51 samples), and fish (31 samples) were collected, which were analyzed chromatographically. Descriptive statistics were performed. The results indicate that CPF was one of the most sold (3.82%) and employed OP (14.74%) during 2021. Only one soil sample was found above the CPF limit of quantification (LOQ); in contrast, all water samples had CPF levels above the LOQ (x̄ = 4614.2 ng/L of CPF). In the case of fish samples, 6.45% demonstrated the presence of methyl-CPF. In conclusion, the information obtained in this study indicates the need for constant monitoring in the area, since the presence of CPF in soil, water, and fish constitutes a threat to the health of wildlife and humans. Therefore, CPF should be banned in Mexico to avoid a serious neurocognitive health problem.


Asunto(s)
Cloropirifos , Insecticidas , Plaguicidas , Animales , Niño , Humanos , Organismos Acuáticos , México , Insecticidas/toxicidad , Suelo , Peces , Agua
3.
J Cardiovasc Electrophysiol ; 33(5): 997-1004, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35322490

RESUMEN

INTRODUCTION: Device infections constitute a major complication of transvenous pacemakers. Mechanical heart valves (MHV) increase the risk of infective endocarditis (IE) and pacemaker infection, requiring lifelong vitamin K-antagonists (VKA), which may affect patient management. Leadless pacemakers (LP) are associated with low infection rates, posing an attractive option in MHV patients requiring permanent pacing. This study describes outcomes following LP implantation in patients with MHV. METHODS: This is a multicenter, observational, retrospective study including consecutive patients implanted with an LP at 5 centers between June 2015 and January 2020. Procedural outcomes, antithrombotic management, complications, performance during follow-up and episodes of bacteremia and IE were compared between patients with and without an MHV (MHV and non-MHV groups). RESULTS: Four hundred fifty-nine patients were included (74 in the MHV group, 16.1%, and 385 in the non-MHV group, 83.9%). Procedural outcomes and acute electrical performance were comparable between groups. Vascular complications and cardiac perforation occurred in 2.7 versus 2.3% (p = 1) and 0% versus 0.8% (p = 1) in the MHV group and non-MHV group. One case of IE occurred in the MHV group and 2 in the non-MHV group. In MHV patients, uninterrupted VKA was used in 83.8%, whereas 16.2% were heparin-bridged. Vascular complication or tamponade occurred in 1 (8.3%) MHV heparin-bridged patient versus 1 (1.6%) MHV uninterrupted VKA patient (p = .3). CONCLUSION: LP implantation outcomes in MHV patients are comparable to the general LP population. Device-related infections are rare following LP implantation, including in patients with MHV. In the MHV group, periprocedural anticoagulation management was not associated with significantly different rates of tamponade or vascular complication.


Asunto(s)
Prótesis Valvulares Cardíacas , Marcapaso Artificial , Válvulas Cardíacas , Heparina , Humanos , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento
4.
J Cardiovasc Electrophysiol ; 33(7): 1472-1479, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35499267

RESUMEN

INTRODUCTION: The Respiratory Disturbance Index (RDI) computed by an implantable cardioverter defibrillator (ICD) algorithm accurately identifies severe sleep apnea (SA). In the present analysis, we tested the hypothesis that RDI could also predict atrial fibrillation (AF) burden. METHODS: Patients with ejection fraction ≤35% implanted with an ICD were enrolled and followed up for 24 months. One month after implantation, patients underwent a polysomnographic study. The weekly mean RDI value was considered, as calculated during the entire follow-up period and over a 1-week period preceding the sleep study. The endpoints were as follows: daily AF burden of ≥5 min, ≥6 h, ≥23 h. RESULTS: Here, 164 patients had usable RDI values during the entire follow-up period. Severe SA (RDI ≥ 30 episodes/h) was diagnosed in 92 (56%) patients at the time of the sleep study. During follow-up, AF burden ≥ 5 min/day was documented in 70 (43%), ≥6 h/day in 48 (29%), and ≥23 h/day in 33 (20%) patients. Device-detected RDI ≥ 30 episodes/h at the time of the polygraphy, as well as the polygraphy-measured apnea hypopnea index ≥ 30 episodes/h, were not associated with the occurrence of the endpoints, using a Cox regression model. However, using a time-dependent model, continuously measured weekly mean RDI ≥ 30 episodes/h was independently associated with AF burden ≥ 5 min/day (hazard ratio [HR]: 2.13, 95% confidence interval [CI]: 1.24-3.65, p = .006), ≥6 h/day (HR: 2.75, 95% CI: 1.37-5.49, p = .004), and ≥23 h/day (HR: 2.26, 95% CI: 1.05-4.86, p = .037). CONCLUSIONS: In heart failure patients, ICD-diagnosed severe SA on follow-up data review identifies patients who are from two- to three-fold more likely to experience an AF episode, according to various thresholds of daily AF burden.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Síndromes de la Apnea del Sueño , Algoritmos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Insuficiencia Cardíaca/complicaciones , Humanos , Síndromes de la Apnea del Sueño/complicaciones , Síndromes de la Apnea del Sueño/diagnóstico , Síndromes de la Apnea del Sueño/terapia
5.
J Psycholinguist Res ; 50(5): 1031-1047, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34312773

RESUMEN

Drawing on sociocultural theory, and multiple empirical studies conducted on the effectiveness of scaffolding on second or foreign language learning, the authors investigated the application of various forms of scaffolding (i.e., teacher versus peer-scaffolding) on EFL learners' incidental vocabulary learning and reading comprehension performance through a sociocultural perspective. To this end, 60 EFL learners out of one-hundred were selected through the administration of an Oxford Placement Test from three language institutes and divided into 3 groups (two experimental and one control group) each including 20 intermediate EFL learners. The first experimental group received teacher-scaffolding instruction, the second experimental group received peer-scaffolding instruction and the control group received traditional instruction with no scaffolding. The vocabulary and reading comprehension pre-tests were administered to the three groups. At the end of the experiment, the vocabulary and reading comprehension post-tests were administered. The descriptive statistics (mean and standard deviation) and the inferential statistics (a One-way ANOVA) were run to analyze the collected data. The results showed that both experimental groups had better performance than the control group and there was a significant difference between teacher-scaffolding and peer-scaffolding in both vocabulary knowledge and reading comprehension performance and the peer-scaffolding group had a better performance than the teacher-scaffolding group. This research provided some implications about different types of scaffolding for language teachers and syllabus designers.


Asunto(s)
Multilingüismo , Vocabulario , Comprensión , Humanos , Aprendizaje , Lectura
6.
J Cardiovasc Electrophysiol ; 31(1): 103-111, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31724763

RESUMEN

INTRODUCTION: Between 7% and 15% of patients with an indication for an implantable cardioverter-defibrillator (ICD) are not eligible for implantation of a subcutaneous implantable cardioverter-defibrillator (S-ICD) on the basis of the result of the conventional left parasternal electrocardiographic screening (LPES). Our objective was to determine the impact of systematically performing right parasternal electrocardiographic screening (RPES) in addition to conventional LPES, in terms of increasing both the total percentage of potentially eligible patients for S-ICD implantation and the number of suitable vectors per patient. METHODS AND RESULTS: Consecutive patients from the outpatient device clinic who already had an implanted ICD, and no requirement for pacing were enrolled. Conventional left parasternal electrode position and right parasternal electrode positions were used. The automatic screening tool was used to analyze the recordings. Screenings were performed in the supine and standing positions. Overall, 209 patients were included. The mean age was 63.4 ± 13 years, 59.8% had ischemic heart disease, mean QRS duration was 100 ± 31 ms, and 69.9% had a primary prevention ICD indication. Based on conventional isolated LPES, 12.9% of patients were not eligible for S-ICD compared with 11.5% based on RPES alone (P = .664). Considering LPES and RPES together, only 7.2% of patients were not eligible for S-ICD (P < .001). Moreover, the number of patients with more than one suitable vector increased from 66.5% with isolated LPES to 82.3% (23.7% absolute increase [P < .001]). CONCLUSION: Adding an automated RPES to the conventional automated LPES increased patient eligibility for the S-ICD significantly. Moreover, combined screening increased the number of suitable vectors per eligible patient.


Asunto(s)
Toma de Decisiones Clínicas , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Electrocardiografía , Determinación de la Elegibilidad , Selección de Paciente , Prevención Primaria/instrumentación , Prevención Secundaria/instrumentación , Anciano , Anciano de 80 o más Años , Muerte Súbita Cardíaca/etiología , Técnicas de Apoyo para la Decisión , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas
7.
J Cardiovasc Electrophysiol ; 31(1): 330-336, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31840881

RESUMEN

BACKGROUND: Leadless pacemakers (L-PM) are an emerging effective and safe technology that offer an alternative to conventional pacemakers (C-PM) for right ventricular stimulation. However, there is little information about their potential benefits for quality of life (QoL) in patients with L-PM. We compared QoL between patients with L-PM and C-PM. METHODS: The study population comprised patients undergoing single chamber pacemaker implantation from December 2016 to March 2018. The SF-36 questionnaire was used to evaluate QoL at baseline and at 6 months of followup. We also used a questionnaire consisted of 10 specific questions related to the implant procedure. RESULTS: A total of 106 patients (64 C-PM; 42 L-PM) were included. There were no differences in baseline characteristics between the groups (C-PM vs L-PM), except for age (81.5 vs 77.3 years; P = .012) and diabetes (38% vs 17%; P = .021). Baseline SF-36 scores did not differ between the groups. At 6 months followup, patients in the L-PM group scored significantly higher on physical function (63 vs 42; P < .001), physical role (64 vs 36; P = .004), and mental health (75 vs 65; P = .017), even after adjusting for covariates. Pacemaker-related discomfort and physical restrictions were significantly lower for the L-PM group. CONCLUSION: L-PM is associated with better QoL than C-PM in both physical and mental health. Patients undergoing L-PM implantation reported less procedure-related discomfort, physical restriction, and preoccupation.


Asunto(s)
Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial , Marcapaso Artificial , Calidad de Vida , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/psicología , Estimulación Cardíaca Artificial/efectos adversos , Diseño de Equipo , Femenino , Estado de Salud , Humanos , Masculino , Salud Mental , España , Encuestas y Cuestionarios , Factores de Tiempo , Resultado del Tratamiento
8.
Cardiovasc Drugs Ther ; 34(1): 89-94, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-32096001

RESUMEN

PURPOSE: The usefulness and mechanisms of antiarrhythmic drug (AAD) pre-treatment as a facilitator of the acute success of electrical cardioversion (ECV) in atrial fibrillation (AF) remain controversial. We sought to analyze the role of AAD treatment with this purpose, differentiating its possible utility either facilitating the restoration of sinus rhythm (SR) or reducing immediate AF recurrences (IAFR). METHODS: We analyzed 2962 consecutive patients with persistent AF undergoing ECV prospectively included in 3 national registries. The acute success of ECV was indicated by the reversion to SR without presenting an IAFR (< 2 h). RESULTS: A total of 1410 patients (48%) received AAD treatment prior to ECV (80% amiodarone, 15% class Ic AAD, 2% other AAD). The rate of restoration of SR was similar between the patients treated with amiodarone (92%), class Ic AAD (91%) and who did not receive AAD pre-treatment (91%) (p = 0.92). However, those treated with amiodarone had fewer IAFR than those in the other two groups (amiodarone 3% vs class Ic 7% vs without treatment 6%; p = 0.002), so the ECV success rate was higher in the amiodarone group than in the other groups (amiodarone 89% vs Ic 84% vs without treatment 86%; p = 0.04). After adjusting for multiple variables, amiodarone remained as an independent predictor of a lower occurrence of IAFR (OR = 0.57; p = 0.01) and of a successful ECV (OR 1.37; p = 0.01). CONCLUSIONS: For patients with persistent AF undergoing ECV, AAD has a neutral effect on the restoration of SR but amiodarone increases its effectiveness due to a lower incidence of IAFR.


Asunto(s)
Amiodarona/uso terapéutico , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/terapia , Cardioversión Eléctrica , Frecuencia Cardíaca/efectos de los fármacos , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Cardioversión Eléctrica/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , España , Factores de Tiempo , Resultado del Tratamiento
9.
Indian Pacing Electrophysiol J ; 20(3): 91-96, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32165268

RESUMEN

BACKGROUND: Premature ventricular contractions (PVC) are known to reduce the percentage of biventricular (BiV) pacing in patients with cardiac resynchronization (CRT), decreasing the clinical response. The aim of this study was to evaluate the prevalence of a high PVC burden, as well as therapeutic action (pharmacotherapy, catheter ablation or device programming), in a large CRT implantable-defibrillator (CRT-D) population. METHODS: Patients with a CRT-D device from the UMBRELLA multicenter prospective remote monitoring registry were included. The PVC count was collected from each remote monitoring transmission. Patients were divided into two high (≥1 transmission ≥200/≥400 PVC/h, respectively) and one low (all transmissions <200 PVC/h) PVC count groups. The PVC burden following a high PVC count transmission was calculated. RESULTS: Of 1268 patients, 135 (11%) and 43 (3.4%) presented high PVC count (≥200/≥400 PVC/h, respectively). The majority of patients in the high PVC groups were not treated (61 [79%] and 32 [74%], respectively. Considering the untreated patients in the high PVC groups, median PVC/h was 199 (interquartile range [IQR]: 196) and 271 (IQR: 330), respectively. The PVC burden (proportion of time with PVC/h ≥ 200/≥400) was 40% (IQR 70) and 29% (IQR 59), respectively. CONCLUSION: A significant proportion of CRT-D patients presented a high PVC count, however, few received treatment. In the untreated patients with a high PVC count, the PVC burden during follow-up varied substantially. Several consecutive recordings of a high PVC count should be warranted before considering therapeutic action such as catheter ablation.

11.
J Cardiovasc Electrophysiol ; 30(9): 1483-1490, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31115940

RESUMEN

INTRODUCTION: Recurrences after atrial fibrillation (AF) ablation are still common. Among the reported clinical and imaging predictors of recurrences, diagnosis-to-ablation time (DAT) has been defined as a predictor of ablation outcome in single-center studies. We aimed to validate DAT in a multicenter real-life cohort. METHODS: This was a multicenter study including consecutive patients undergoing first paroxysmal and persistent AF ablation with radiofrequency or cryoballoon catheters during 2013. Cox proportional hazard regression models were performed to identify predictors of recurrence. RESULTS: In total, 309 patients were included across nine centers (71% men, 57 ± 10 years old, 46% with hypertension, and 66% with CHA2 DS2 -VASc ≤ 1). Most patients had paroxysmal AF (67%) and underwent radiofrequency ablation (68%) with a median DAT of 51 (43) months. Patients with DAT ≤ 1 year (16.6%) were less likely to have repeat procedures (4% vs 18%; P = .017). The adjusted proportional hazards Cox model identified hypertension (P = .005), heart failure (P = .011), nonparoxysmal AF (P = .038), DAT > 1 year (P = .007), and LA diameter (P = .026) as independent predictors for AF recurrence. DAT > 1 year was the only modifiable factor independently associated with recurrence (HR 4.2 [95% CI, 1.5-11.9]) CONCLUSION: Diagnosis-to-ablation time is a modifiable factor independently associated with recurrent arrhythmia and repeat ablation after first AF ablation. An early intervention strategy during the first year from AF diagnosis might improve outcomes.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Criocirugía , Venas Pulmonares/cirugía , Tiempo de Tratamiento , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Recurrencia , Medición de Riesgo , Factores de Riesgo , España , Factores de Tiempo , Resultado del Tratamiento
12.
Pacing Clin Electrophysiol ; 42(6): 625-633, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30888071

RESUMEN

BACKGROUND: The differential diagnosis of regular wide QRS complex tachycardia (RWQRST) remains the subject of numerous publications, all of which aim at diagnosis during the acute phase. Although an accurate diagnosis is necessary to make long-term decisions, it often leads to invasive testing. METHODS: Criteria with high positive predictive values (PPVs) for diagnosis can be obtained by analyzing the electrocardiogram (ECG) data during RWQRST and comparing them with these data at baseline. By assigning points to these criteria, a scoring algorithm to accurately diagnose numerous patients can be obtained. A total of 352 consecutive patients with RWQRST were included. Two electrophysiologists blind to patient condition analyzed the 16 criteria considered as having high PPVs. RESULTS: A total of 149 (42.3%) cases were supraventricular tachycardia (SVT), and 203 (57.7%) cases were ventricular tachycardia (VT). A higher percentage of patients with VT had structural heart disease (86.7% vs 16.1%). Seven of the 16 criteria analyzed had PPVs > 95%, and each criterion was assigned a score. A final score of -1 was indicative of SVT (PPV 98%); a score of 1 was indicative of VT (PPV 98%); and a score of ≥2 was indicative of VT (PPV 100%). A score of ≠0 was obtained for 51.7% of all cases of tachycardia, making it possible to reach a highly accurate diagnosis in approximately half of all cases. No cases of VT scored -1, and no cases of SVT scored ≥2. CONCLUSIONS: The current scoring system stands out for its high PPV (98%) and specificity (98%), enabling an accurate diagnosis for more than half of the patients.


Asunto(s)
Algoritmos , Electrocardiografía , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Taquicardia Supraventricular/fisiopatología , Taquicardia Ventricular/fisiopatología
13.
Europace ; 20(7): 1161-1167, 2018 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-29036370

RESUMEN

Aims: Multipoint pacing (MPP) permits simultaneous multisite pacing of the left ventricle (LV); initial studies suggest haemodynamic and clinical benefits over conventional (single LV site) cardiac resynchronization therapy (CRT). The aim of this study was to estimate the impact of MPP activation on battery longevity in routine clinical practice. Methods and results: Patient (n = 46) and device data were collected from two centres at least 3 months after MPP-CRT device implantation. Multipoint pacing programming was based on the maximal possible anatomical LV1/LV2 separation according to three predefined LV pacing capture threshold (PCT) cut-offs (≤1.5 V; ≤4.0 V; and ≤6.5 V). Estimated battery longevity was calculated using the programmed lower rate limit, lead impedances, outputs, and pacing percentages. Relative to the longevity for conventional CRT using the lowest PCT (8.9 ± 1.2 years), MPP activation significantly shortened battery longevity for all three PCT cut-offs (≤1.5 V, -5.6%; ≤4.0 V, -16.9%; ≤6.5 V, -21.3%; P's <0.001). When compared with conventional CRT based on longest right ventricle-LV delay (8.3 ± 1.3 years), battery longevity was significantly shortened for the MPP ≤ 4.0 V and ≤6.5 V cut-offs (-10.8 and -15.7%, respectively; P's <0.001). Maximal LV1/LV2 spacing was possible in 23.9% (≤1.5 V), 56.5% (≤4.0 V), and 69.6% (≤6.5 V) of patients. Conclusion: Multipoint pacing activation significantly reduces battery longevity compared with that for conventional CRT configuration. When reasonable MPP LV vector PCTs (≤4.0 V) are achieved, the decrease in battery longevity is relatively small which may prompt the clinician to activate MPP.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca/métodos , Suministros de Energía Eléctrica , Insuficiencia Cardíaca/terapia , Función Ventricular Izquierda , Anciano , Terapia de Resincronización Cardíaca/efectos adversos , Estudios Transversales , Falla de Equipo , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , España , Factores de Tiempo , Resultado del Tratamiento
14.
Europace ; 20(10): 1638-1646, 2018 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-29300867

RESUMEN

Aims: Tachycardia mediated by septal accessory pathways (AP) and atypical atrioventricular nodal re-entry (AVNRT) require careful electrophysiologic evaluation for differential diagnosis. We aim to describe the differential behaviour of local ventriculo-atrial (VA) intervals which predicts the tachycardia mechanism. Methods and results: The local VA intervals at the para-Hisian septum were measured under three different situations: (i) tachycardia; (ii) sustained entrainment from the right ventricular apex (RVA); and (iii) continuous pacing from the RVA during sinus rhythm. Differences were computed as follows: Δ-VAentr = VA during entrainment - VA during tachycardia; and Δ-VApac = VA while pacing during sinus rhythm - VA during tachycardia. In contrast to AVNRT, we hypothesized that an invariable retrograde conduction through the septal AP will keep the result of the subtractions close to 0 ms in cases of ortodromic atrioventricular re-entrant tachycardia (AVRT). We analysed 55 atypical AVNRT (45% posterior type) and 82 AVRT (10 anteroseptal, 18 para-Hisian, 12 mid-septal, and 42 posteroseptal). Δ-VAentr was longer for AVNRT (98.5 ± 40.3 ms) compared with septal AP (-5.7 ± 19.3 ms; P < 0.001). A value of 50 ms showed 98.7% sensitivity and 92% specificity (AUC 0.99; 95% CI 0.98-1). According to physiological criteria, a negative Δ-VAentr remains unobserved in the case of AVNRT (positive predictive value 100% for septal AP). Δ-VApac was also longer for AVNRT (66.5 ± 14.6 ms) compared with septal AP (-9.7 ± 3.3 ms; P < 0.001). A value of 50 ms showed 100% sensitivity and 74% specificity (AUC 0.86; 95% CI 0.76-0.93). Conclusions: Delta of the local VA intervals enables distinction between atypical AVNRT and AVRT mediated by septal AP.


Asunto(s)
Fascículo Atrioventricular Accesorio/fisiopatología , Técnicas Electrofisiológicas Cardíacas/métodos , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Fascículo Atrioventricular Accesorio/diagnóstico , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico
15.
Europace ; 20(5): 851-858, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-28387796

RESUMEN

Aims: Coronary artery spasm (CAS) is associated with ventricular arrhythmias (VA). Much controversy remains regarding the best therapeutic interventions for this specific patient subset. We aimed to evaluate the clinical outcomes of patients with a history of life-threatening VA due to CAS with various medical interventions, as well as the need for ICD placement in the setting of optimal medical therapy. Methods and results: A multicentre European retrospective survey of patients with VA in the setting of CAS was aggregated and relevant clinical and demographic data was analysed. Forty-nine appropriate patients were identified: 43 (87.8%) presented with VF and 6 (12.2%) with rapid VT. ICD implantation was performed in 44 (89.8%). During follow-up [59 (17-117) months], appropriate ICD shocks were documented in 12. In 8/12 (66.6%) no more ICD therapies were recorded after optimizing calcium channel blocker (CCB) therapy. SCD occurred in one patient without ICD. Treatment with beta-blockers was predictive of appropriate device discharge. Conversely, non-dihydropyridine CCB therapy was significantly protective against VAs. Conclusion: Patients with life-threatening VAs secondary to CAS are at particularly high-risk for recurrence, especially when insufficient medical therapy is administered. Non-dihydropyridine CCBs are capable of suppressing episodes, whereas beta-blocker treatment is predictive of VAs. Ultimately, in spite of medical intervention, some patients exhibited arrhythmogenic events in the long-term, suggesting that ICD implantation may still be indicated for all.


Asunto(s)
Antagonistas Adrenérgicos beta/uso terapéutico , Bloqueadores de los Canales de Calcio/uso terapéutico , Vasoespasmo Coronario , Muerte Súbita Cardíaca , Efectos Adversos a Largo Plazo , Fibrilación Ventricular , Vasoespasmo Coronario/complicaciones , Vasoespasmo Coronario/tratamiento farmacológico , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/estadística & datos numéricos , Europa (Continente)/epidemiología , Femenino , Humanos , Efectos Adversos a Largo Plazo/diagnóstico , Efectos Adversos a Largo Plazo/prevención & control , Masculino , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Prevención Secundaria/métodos , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/etiología , Fibrilación Ventricular/mortalidad , Fibrilación Ventricular/terapia
16.
Pacing Clin Electrophysiol ; 41(10): 1362-1364, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30091468

RESUMEN

A 16-year-old male presented with an orthodromic atrioventricular reentrant tachycardia over a concealed parahisian accessory pathway (AP). Cryoablation of the AP resulted in transient manifestation of a fully preexcited sinus rhythm of parahisian AP morphology. Potential causes for the paradoxical preexcitation include inadvertent atrioventricular nodal block, sourse-sink mismatch, as well as the activation of a dormant AP capable of anterograde conduction.


Asunto(s)
Fascículo Atrioventricular Accesorio/cirugía , Fascículo Atrioventricular/cirugía , Criocirugía/métodos , Síndromes de Preexcitación/etiología , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Fascículo Atrioventricular Accesorio/fisiopatología , Adolescente , Fascículo Atrioventricular/fisiopatología , Electrocardiografía , Humanos , Masculino , Síndromes de Preexcitación/fisiopatología , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología
17.
J Electrocardiol ; 51(6): 941-944, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30497752

RESUMEN

We report on a case of a 78-years-old patient with a subcutaneous implantable cardioverter defibrillator (S-ICD) and an episode of a sustained ventricular tachycardia (VT) at a rate slower than the programmed shock zone. Because of T-wave oversensing the device interpreted it as fast VT that triggered the delivery of an "inappropriately appropriate shock" that terminated it. The patient had again more VT episodes but after programming the SMART pass algorithm (previously programmed "OFF") the device showed no longer frequent T-wave oversensing and no additional inappropriate shocks occurred.


Asunto(s)
Algoritmos , Desfibriladores Implantables , Taquicardia Ventricular/fisiopatología , Anciano , Falla de Equipo , Humanos , Masculino
18.
J Cancer Educ ; 33(1): 160-166, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-27357140

RESUMEN

To analyze the key successful factors of a national educational strategy for early breast cancer detection developed in Mexico for primary health care personnel from 2008 to 2014, an educational strategy to train physicians, nurses, health promoters, and medical students from local ministries of health with a competency-based approach was developed and implemented using diverse educational modalities, face-to-face, blended, and a massive open online course (MOOC). Formative and summative evaluations were used during the implementation of the course. A total of 19,563 health professionals were trained from 2008 to 2014. The graduation rate, an average of all educational modalities, was 91 %, much higher than those previously reported in the literature. The factors that might have influenced this success were (1) the training strategy, which was designed according to the characteristics and specific needs of the target groups; (2) the political will and commitment of the country's health authorities; (3) the technological and educational models used; and (4) the punctual follow-up of participants. This study shows that carefully designed educational interventions can improve service professionals' competencies and that regardless of the modality, face-to-face, blended learning, or MOOC, high graduation rates can be achieved. Further evaluation is required to demonstrate that the competencies remained in all target groups after 6 months of the intervention and that the women served by the trained personnel were provided accurate information and timely diagnoses of breast cancer.


Asunto(s)
Neoplasias de la Mama/prevención & control , Competencia Clínica , Personal de Salud/educación , Promoción de la Salud , Modelos Educacionales , Médicos/normas , Neoplasias de la Mama/epidemiología , Femenino , Humanos , Aprendizaje , México/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA