Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Sci Rep ; 10(1): 8445, 2020 05 21.
Artículo en Inglés | MEDLINE | ID: mdl-32439873

RESUMEN

Artificial intelligence (AI) is developing rapidly in the medical technology field, particularly in image analysis. ECG-diagnosis is an image analysis in the sense that cardiologists assess the waveforms presented in a 2-dimensional image. We hypothesized that an AI using a convolutional neural network (CNN) may also recognize ECG images and patterns accurately. We used the PTB ECG database consisting of 289 ECGs including 148 myocardial infarction (MI) cases to develop a CNN to recognize MI in ECG. Our CNN model, equipped with 6-layer architecture, was trained with training-set ECGs. After that, our CNN and 10 physicians are tested with test-set ECGs and compared their MI recognition capability in metrics F1 (harmonic mean of precision and recall) and accuracy. The F1 and accuracy by our CNN were significantly higher (83 ± 4%, 81 ± 4%) as compared to physicians (70 ± 7%, 67 ± 7%, P < 0.0001, respectively). Furthermore, elimination of Goldberger-leads or ECG image compression up to quarter resolution did not significantly decrease the recognition capability. Deep learning with a simple CNN for image analysis may achieve a comparable capability to physicians in recognizing MI on ECG. Further investigation is warranted for the use of AI in ECG image assessment.


Asunto(s)
Algoritmos , Inteligencia Artificial , Bases de Datos Factuales , Aprendizaje Profundo , Electrocardiografía/métodos , Infarto del Miocardio/diagnóstico , Redes Neurales de la Computación , Humanos , Infarto del Miocardio/diagnóstico por imagen
2.
Anatol J Cardiol ; 19(6): 382-387, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29848922

RESUMEN

OBJECTIVE: In-stent restenosis (ISR) is a feared complication after coronary stent implantation. Drug-coated balloon (DCB) is being promoted as a treatment option for ISR. However, the benefit-risk ratio of DCB length has not been investigated. Longer DCBs release more anti-proliferative drug to the vessel wall; however, they are associated with a higher lesion length and vessel injury. HYPOTHESIS: DCB length is associated with clinical outcome. METHODS: We analyzed 286 consecutive Pantera Lux (Biotronik, active component Paclitaxel) DCB-treated patients between April 2009 and June 2012. Of them, 176 patients were treated using a 15-mm DCB and 109 were treated using a 20-mm DCB. Baseline characteristics and major adverse cardiac events (MACE; death, myocardial infarction, and target lesion revascularization) during initial hospital stay and a 2-year follow-up period were obtained. RESULTS: Patients characteristics such as cardiovascular risk factors, prior diseases, co-medication, clinical presentation, target vessel, and left ventricular function did not differ between the groups. MACE during hospital course was similar [1.7% vs. 2.8%, relative risk (RR) 1.6, 95% confidence interval (CI) 0.3-7.9, p=0.554]. Likewise, at 2-year follow-up, MACE did not differ between the groups (23.2% vs. 27.5%, RR 1.2, 95% CI 0.6-1.5, p=0.408). CONCLUSION: DCB length was not associated with clinical outcome during a 2-year follow-up period.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Reestenosis Coronaria/etiología , Stents Liberadores de Fármacos/efectos adversos , Anciano , Angioplastia Coronaria con Balón , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Resultado del Tratamiento
3.
Int J Cardiol ; 231: 68-72, 2017 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-28089147

RESUMEN

BACKGROUND: In-stent restenosis (ISR) is still a major concern in interventional cardiology. Drug coated balloon (DCB) angioplasty has been shown to be a promising option in treatment of ISR. However heterogeneity of different DCBs in suppression of neointimal growth has been described in a porcine model of coronary ISR. Therefore, in this registry analysis, we compared two frequently used paclitaxel eluting DCBs, the SeQuent Please and the Pantera Lux DCB. METHODS: 571 patients were treated with DCB angioplasty at the Heinrich-Heine University Düsseldorf between 2009 and 2012. Follow-up was conducted during ambulatory care at our department. Major adverse cardiac events (death, myocardial infarction [MI] and target lesion revascularization) were registered during hospitalization and follow-up. RESULTS: Patient characteristics, prior diseases, clinical presentation, ejection fraction, procedural success and lost-for-follow-up did not differ between patients treated with the SeQuent Please and. The Pantera Lux DCB. MACE during hospital course were similar as well (Pantera Lux: 6 patients [1.6%] vs. SeQuent®Please: 3 patients [1.5%], relative risk 1.06, 95% confidence interval 0.3-4.2, P=0.93). Event free survival was significantly longer in patients treated with the Pantera Lux DCB as compared to SeQuent Please DCB (Hazard ratio: 0.65, 95% confidence interval 0.43-0.98; P value of log-rank test: 0.0405). CONCLUSION: MACE free survival was longer in Pantera Lux DCB treated patients as compared to SeQuent Please treated patients. This finding has to be confirmed in future clinical trials.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/cirugía , Reestenosis Coronaria/prevención & control , Stents Liberadores de Fármacos , Paclitaxel/farmacología , Sistema de Registros , Anciano , Antineoplásicos Fitogénicos/farmacología , Causas de Muerte/tendencias , Reestenosis Coronaria/epidemiología , Femenino , Alemania/epidemiología , Humanos , Incidencia , Masculino , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA