Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Clin Orthop Relat Res ; 474(12): 2633-2640, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27535284

RESUMEN

BACKGROUND: Osteochondroplasty of the head-neck region is performed on patients with cam femoroacetabular impingement (FAI) without fully understanding its repercussion on the integrity of the femur. Cam-type FAI can be surgically and reproducibly induced in the ovine femur, which makes it suitable for studying corrective surgery in a consistent way. Finite element models built on quantitative CT (QCT) are computer tools that can be used to predict femoral strength and evaluate the mechanical effect of surgical correction. QUESTIONS/PURPOSES: We asked: (1) What is the effect of a resection of the superolateral aspect of the ovine femoral head-neck junction on failure load? (2) How does the failure load after osteochondroplasty compare with reported forces from activities of daily living in sheep? (3) How do failure loads and failure locations from the computer simulations compare with the experiments? METHODS: Osteochondroplasties (3, 6, 9 mm) were performed on one side of 18 ovine femoral pairs with the contralateral intact side as a control. The 36 femurs were scanned via QCT from which specimen-specific computer models were built. Destructive compression tests then were conducted experimentally using a servohydraulic testing system and numerically via the computer models. Safety factors were calculated as the ratio of the maximal force measured in vivo by telemeterized hip implants during the sheep's walking and running activities to the failure load. The simulated failure loads and failure locations from the computer models were compared with the experimental results. RESULTS: Failure loads were reduced by 5% (95% CI, 2%-8%) for the 3-mm group (p = 0.0089), 10% (95% CI, 6%-14%) for the 6-mm group (p = 0.0015), and 19% (95% CI, 13%-26%) for the 9-mm group (p = 0.0097) compared with the controls. Yet, the weakest specimen still supported more than 2.4 times the peak load during running. Strong correspondence was found between the simulated and experimental failure loads (R2 = 0.83; p < 0.001) and failure locations. CONCLUSIONS: The resistance of ovine femurs to fracture decreased with deeper resections. However, under in vitro testing conditions, the effect on femoral strength remains small even after 9 mm correction, suggesting that femoral head-neck osteochondroplasty could be done safely on the ovine femur. QCT-based finite element models were able to predict weakening of the femur resulting from the osteochondroplasty. CLINICAL RELEVANCE: The ovine femur provides a seemingly safe platform for scientific evaluation of FAI. It also appears that computer models based on preoperative CT scans may have the potential to provide patient-specific guidelines for preventing overcorrection of cam FAI.


Asunto(s)
Simulación por Computador , Pinzamiento Femoroacetabular/cirugía , Fracturas del Cuello Femoral/prevención & control , Cabeza Femoral/cirugía , Cuello Femoral/cirugía , Análisis de Elementos Finitos , Modelos Biológicos , Procedimientos Ortopédicos , Animales , Fenómenos Biomecánicos , Modelos Animales de Enfermedad , Femenino , Pinzamiento Femoroacetabular/fisiopatología , Fracturas del Cuello Femoral/etiología , Fracturas del Cuello Femoral/fisiopatología , Cabeza Femoral/diagnóstico por imagen , Cabeza Femoral/fisiopatología , Cuello Femoral/diagnóstico por imagen , Cuello Femoral/fisiopatología , Procedimientos Ortopédicos/efectos adversos , Osteotomía , Factores de Riesgo , Ovinos , Estrés Mecánico , Tomografía de Coherencia Óptica , Insuficiencia del Tratamiento
2.
Nat Mater ; 13(7): 740-7, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24907926

RESUMEN

Ageing societies suffer from an increasing incidence of bone fractures. Bone strength depends on the amount of mineral measured by clinical densitometry, but also on the micromechanical properties of the hierarchical organization of bone. Here, we investigate the mechanical response under monotonic and cyclic compression of both single osteonal lamellae and macroscopic samples containing numerous osteons. Micropillar compression tests in a scanning electron microscope, microindentation and macroscopic compression tests were performed on dry ovine bone to identify the elastic modulus, yield stress, plastic deformation, damage accumulation and failure mechanisms. We found that isolated lamellae exhibit a plastic behaviour, with higher yield stress and ductility but no damage. In agreement with a proposed rheological model, these experiments illustrate a transition from a ductile mechanical behaviour of bone at the microscale to a quasi-brittle response driven by the growth of cracks along interfaces or in the vicinity of pores at the macroscale.


Asunto(s)
Huesos/fisiología , Fuerza Compresiva , Animales , Fenómenos Biomecánicos , Huesos/ultraestructura , Microscopía Electrónica de Rastreo , Ovinos/anatomía & histología , Ovinos/fisiología , Estrés Mecánico
3.
J Mater Sci Mater Med ; 26(2): 87, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25644101

RESUMEN

The aim of this study was to analyse the osseointegrative potential of phosphoserine-tethered dendrons when applied as surface functionalisation molecules on titanium implants in a sheep model after 2 and 8 weeks of implantation. Uncoated and dendron-coated implants were implanted in six sheep. Sandblasted and etched (SE) or porous additive manufactured (AM) implants with and without additional dendron functionalisation (SE-PSD; AM-PSD) were placed in the pelvic bone. Three implants per group were examined histologically and six implants were tested biomechanically. After 2 and 8 weeks the bone-to-implant contact (BIC) total values of SE implants (43.7±12.2; 53.3±9.0%) and SE-PSD (46.7±4.5; 61.7±4.9%) as well as AM implants (20.49±5.1; 43.9±9.7%) and AM-PSD implants (19.7±3.5; 48.3±15.6%) showed no statistically significant differences. For SE-PSD and AM-PSD a separate analysis of only the cancellous BIC demonstrated a statistically significant difference after 2 and 8 weeks. Biomechanical findings proved the overall increased stability of the porous implants after 8 weeks. Overall, the great effect of implant macro design on osseointegration was further supported by additional phosphoserine-tethered dendrons for SE and AM implants.


Asunto(s)
Oseointegración , Prótesis e Implantes , Titanio , Animales , Materiales Biocompatibles Revestidos , Dendrímeros , Femenino , Colorantes Fluorescentes , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Modelos Animales , Fosfoserina , Polilisina , Oveja Doméstica , Propiedades de Superficie , Factores de Tiempo , Torque
4.
Vet Surg ; 44(8): 957-63, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26413939

RESUMEN

OBJECTIVE: To compare the biomechanical properties of a ventral transarticular lag screw fixation technique, a new dorsal atlantoaxial instability (AAI) clamp, and a new ventral AAI hook plate under sagittal shear loading after transection of the ligaments of the atlantoaxial joint. STUDY DESIGN: Cadaveric biomechanical study. ANIMALS: Canine cadavers (n = 10). MATERIALS AND METHODS: The occipitoatlantoaxial region of Beagles euthanatized for reasons unrelated to the study was prepared leaving only ligamentous structures and the joint capsules between the first 2 cervical vertebrae (C1 and C2). The atlanto-occipital joints were stabilized with 2 transarticular diverging positive threaded K-wires. The occipital bone and the caudal end of C2 were embedded in polymethylmethacrylate and loaded in shear to a force of 50 Newtons. The range of motion (ROM) and neutral zone (NZ) of the atlantoaxial joint were determined after 3 loading cycles with atlantoaxial ligaments intact, after ligament transection, and after fixation with each implant. The testing order of implants was randomly assigned. The implants tested last were subjected to failure testing. RESULTS: All stabilization procedures decreased the ROM and NZ of the atlantoaxial joint compared to transected ligament specimens. Only stabilization with transarticular lag screws and ventral plates produced a significant reduction of ROM compare to intact specimens. CONCLUSION: Fixation with transarticular lag screws and a ventral hook plate was biomechanically similar and provided more rigidity compared to dorsal clamp fixation. Further load cycling to failure tests and clinical studies are required before making clinical recommendations.


Asunto(s)
Articulación Atlantoaxoidea/cirugía , Articulación Atlantooccipital/cirugía , Placas Óseas/veterinaria , Tornillos Óseos/veterinaria , Perros/cirugía , Inestabilidad de la Articulación/cirugía , Animales , Fenómenos Biomecánicos , Cadáver , Ligamentos/cirugía , Resistencia al Corte
5.
Vet Surg ; 42(7): 825-31, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24033669

RESUMEN

OBJECTIVE: To evaluate fixation properties of a new intervertebral anchored fusion device and compare these with ventral locking plate fixation. STUDY DESIGN: In vitro biomechanical evaluation. ANIMALS: Cadaveric canine C4-C7 cervical spines (n = 9). METHODS: Cervical spines were nondestructively loaded with pure moments in a nonconstraining testing apparatus to induce flexion/extension while angular motion was measured. Range of motion (ROM) and neutral zone (NZ) were calculated for (1) intact specimens, (2) specimens after discectomy and fixation with a purpose-built intervertebral fusion cage with integrated ventral fixation, and (3) after removal of the device and fixation with a ventral locking plate. RESULTS: Both fixation techniques resulted in a decrease in ROM and NZ (P < .001) compared with the intact segments. There were no significant differences between the anchored spacer and locking plate fixation. CONCLUSION: An anchored spacer appears to provide similar biomechanical stability to that of locking plate fixation.


Asunto(s)
Placas Óseas/veterinaria , Vértebras Cervicales/cirugía , Perros , Fusión Vertebral/veterinaria , Animales , Fenómenos Biomecánicos , Cadáver , Fusión Vertebral/instrumentación
6.
Vet Surg ; 42(8): 918-23, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24117887

RESUMEN

OBJECTIVES: To evaluate the stabilizing function of atlanto-axial ligaments in dogs. STUDY DESIGN: Cadaveric biomechanical study. ANIMALS: Beagle dog cadavers (n = 10). METHODS: The craniocervical region was collected from 10 Beagle cadavers, and the occipito-atlanto-axial region was prepared and freed from the surrounding muscles. Care was taken to preserve integrity of the atlantoaxial ligaments and atlantoaxial joint capsule. The atlanto-occipital joints were blocked with 2 diverging transarticular 1.8 mm positive threaded K-wires. Specimen extremities were embedded in polymethylmethacrylate (PMMA) and mounted on a simulator testing shear load at the atlantoaxial joint. Range of motion (ROM) and neutral zone (NZ) were determined with all ligaments intact, after cutting the apical ligament, both alar ligaments, the transverse ligaments and finally after cutting the dorsal atlantoaxial ligament. RESULTS: ROM increased similarly and stepwise during testing. The most significant increase was observed after transection of the alar ligaments. CONCLUSION: The alar ligaments seem to be the most important ligamentous structures for stabilization of the atlantoaxial joint under shear load.


Asunto(s)
Articulación Atlantoaxoidea/anatomía & histología , Articulación Atlantoaxoidea/fisiología , Perros/fisiología , Ligamentos Articulares/anatomía & histología , Ligamentos Articulares/fisiología , Animales , Fenómenos Biomecánicos , Cadáver , Perros/anatomía & histología , Femenino , Masculino , Rango del Movimiento Articular , Resistencia al Corte
7.
Acta Biomater ; 167: 83-99, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37127075

RESUMEN

The development of treatment strategies for skeletal diseases relies on the understanding of bone mechanical properties in relation to its structure at different length scales. At the microscale, indention techniques can be used to evaluate the elastic, plastic, and fracture behaviour of bone tissue. Here, we combined in situ high-resolution SRµCT indentation testing and digital volume correlation to elucidate the anisotropic crack propagation, deformation, and fracture of ovine cortical bone under Berkovich and spherical tips. Independently of the indenter type we observed significant dependence of the crack development due to the anisotropy ahead of the tip, with lower strains and smaller crack systems developing in samples indented in the transverse material direction, where the fibrillar bone ultrastructure is largely aligned perpendicular to the indentation direction. Such alignment allows to accommodate the strain energy, inhibiting crack propagation. Higher tensile hoop strains generally correlated with regions that display significant cracking radial to the indenter, indicating a predominant Mode I fracture. This was confirmed by the three-dimensional analysis of crack opening displacements and stress intensity factors along the crack front obtained for the first time from full displacement fields in bone tissue. The X-ray beam significantly influenced the relaxation behaviour independent of the tip. Raman analyses did not show significant changes in specimen composition after irradiation compared to non-irradiated tissue, suggesting an embrittlement process that may be linked to damage of the non-fibrillar organic matrix. This study highlights the importance of three-dimensional investigation of bone deformation and fracture behaviour to explore the mechanisms of bone failure in relation to structural changes due to ageing or disease. STATEMENT OF SIGNIFICANCE: Characterising the three-dimensional deformation and fracture behaviour of bone remains essential to decipher the interplay between structure, function, and composition with the aim to improve fracture prevention strategies. The experimental methodology presented here, combining high-resolution imaging, indentation testing and digital volume correlation, allows us to quantify the local deformation, crack propagation, and fracture modes of cortical bone tissue. Our results highlight the anisotropic behaviour of osteonal bone and the complex crack propagation patterns and fracture modes initiating by the intricate stress states beneath the indenter tip. This is of wide interest not only for the understanding of bone fracture but also to understand other architectured (bio)structures providing an effective way to quantify their toughening mechanisms in relation to their main mechanical function.


Asunto(s)
Fracturas Óseas , Sincrotrones , Ovinos , Animales , Anisotropía , Huesos , Hueso Cortical/diagnóstico por imagen , Fracturas Óseas/diagnóstico por imagen , Estrés Mecánico
8.
BMC Musculoskelet Disord ; 13: 222, 2012 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-23150982

RESUMEN

BACKGROUND: It has been demonstrated that frequency modulation of loading influences cellular response and metabolism in 3D tissues such as cartilage, bone and intervertebral disc. However, the mechano-sensitivity of cells in linear tissues such as tendons or ligaments might be more sensitive to changes in strain amplitude than frequency. Here, we hypothesized that tenocytes in situ are mechano-responsive to random amplitude modulation of strain. METHODS: We compared stochastic amplitude-modulated versus sinusoidal cyclic stretching. Rabbit tendon were kept in tissue-culture medium for twelve days and were loaded for 1h/day for six of the total twelve culture days. The tendons were randomly subjected to one of three different loading regimes: i) stochastic (2 - 7% random strain amplitudes), ii) cyclic_RMS (2-4.42% strain) and iii) cyclic_high (2 - 7% strain), all at 1 Hz and for 3,600 cycles, and one unloaded control. RESULTS: At the end of the culture period, the stiffness of the "stochastic" group was significantly lower than that of the cyclic_RMS and cyclic_high groups (both, p < 0.0001). Gene expression of eleven anabolic, catabolic and inflammatory genes revealed no significant differences between the loading groups. CONCLUSIONS: We conclude that, despite an equivalent metabolic response, stochastically stretched tendons suffer most likely from increased mechanical microdamage, relative to cyclically loaded ones, which is relevant for tendon regeneration therapies in clinical practice.


Asunto(s)
Mecanotransducción Celular , Traumatismos de los Tendones/fisiopatología , Tendones/fisiopatología , Animales , Fenómenos Biomecánicos , Proliferación Celular , Células Cultivadas , ADN/metabolismo , Elasticidad , Femenino , Regulación de la Expresión Génica , Glicosaminoglicanos/metabolismo , Conejos , Procesos Estocásticos , Estrés Mecánico , Traumatismos de los Tendones/genética , Traumatismos de los Tendones/metabolismo , Traumatismos de los Tendones/patología , Tendones/metabolismo , Tendones/patología , Factores de Tiempo , Soporte de Peso
9.
BMC Musculoskelet Disord ; 13: 32, 2012 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-22400715

RESUMEN

BACKGROUND: In the present study, 4 different metallic implant materials, either partly coated or polished, were tested for their osseointegration and biocompatibility in a pelvic implantation model in sheep. METHODS: Materials to be evaluated were: Cobalt-Chrome (CC), Cobalt-Chrome/Titanium coating (CCTC), Cobalt-Chrome/Zirconium/Titanium coating (CCZTC), Pure Titanium Standard (PTST), Steel, TAN Standard (TANST) and TAN new finish (TANNEW). Surgery was performed on 7 sheep, with 18 implants per sheep, for a total of 63 implants. After 8 weeks, the specimens were harvested and evaluated macroscopically, radiologically, biomechanically (removal torque), histomorphometrically and histologically. RESULTS: Cobalt-Chrome screws showed significantly (p = 0.031) lower removal torque values than pure titanium screws and also a tendency towards lower values compared to the other materials, except for steel. Steel screws showed no significant differences, in comparison to cobalt-chrome and TANST, however also a trend towards lower torque values than the remaining materials. The results of the fluorescence sections agreed with those of the biomechanical test. Histomorphometrically, there were no significant differences of bone area between the groups. The BIC (bone-to-implant-contact), used for the assessment of the osseointegration, was significantly lower for cobalt-chrome, compared to steel (p = 0.001). Steel again showed a lower ratio (p = 0.0001) compared to the other materials. CONCLUSION: This study demonstrated that cobalt-chrome and steel show less osseointegration than the other metals and metal-alloys. However, osseointegration of cobalt-chrome was improved by zirconium and/or titanium based coatings (CCTC, TANST, TAN, TANNEW) being similar as pure titanium in their osseointegrative behavior.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Tornillos Óseos/normas , Ensayo de Materiales/métodos , Metales/farmacología , Oseointegración/fisiología , Implantación de Prótesis/métodos , Animales , Artroplastia de Reemplazo de Cadera/métodos , Materiales Biocompatibles Revestidos/farmacología , Materiales Biocompatibles Revestidos/uso terapéutico , Femenino , Metales/uso terapéutico , Modelos Animales , Oveja Doméstica
10.
Vet Surg ; 41(2): 228-34, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22092156

RESUMEN

OBJECTIVE: To analyze the biomechanical changes induced by partial lateral corpectomy (PLC) and a combination of PLC and hemilaminectomy in a T13-L3 spinal segment in nonchondrodystrophic dogs. STUDY DESIGN: In vitro biomechanical cadaveric study. SAMPLE POPULATION: T13-L3 spinal segments (n = 10) of nonchondrodystrophic dogs (weighing, 25-38 kg). METHODS: A computed tomography (CT) scan of each T13-L3 spinal segment was performed. A loading simulator for flexibility analysis was used to determine the range of motion (ROM) and neutral zone (NZ) during flexion/extension, lateral bending, and axial rotation. A servohydraulic testing machine was used to determine the changes in stiffness during compression, dorsoventral, and lateral shear. All spines were tested intact, after PLC in the left intervertebral space of L1-L2, and after a combination of PLC and hemilaminectomy. RESULTS: Statistically significant increases in ROM and NZ (P < .05) were detected during flexion/extension and lateral bending when PLC was performed. A significant increase in ROM (P < .001) was noted during axial rotation and flexion after PLC and hemilaminectomy. Stiffness decreased significantly during compression and dorsoventral shear after each procedure. Decreased stiffness during lateral shear was only significant after a combination of both procedures. CONCLUSION: PLC might lead to some spinal instability; these changes are enhanced when a hemilaminectomy is added.


Asunto(s)
Perros/cirugía , Laminectomía/veterinaria , Vértebras Lumbares/cirugía , Vértebras Torácicas/cirugía , Animales , Fenómenos Biomecánicos , Cadáver , Fuerza Compresiva/fisiología , Disco Intervertebral/fisiología , Laminectomía/métodos , Movimiento/fisiología , Rango del Movimiento Articular/fisiología
11.
JSES Rev Rep Tech ; 1(4): 414-420, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37588712

RESUMEN

Background: Olecranon osteotomies are frequently used to expose distal humeral intraarticular fractures. The step-cut olecranon osteotomy (SCOOT) is an augmented version of the oblique olecranon osteotomy, which has recently been evaluated biomechanically with tension band wiring (TBW) fixation. However, complications with TBW are common. In this study, we, therefore, compared the mean load to failure of TBW with compression screws for SCOOT fixation. We hypothesized a higher load to failure for the compression screw group. Methods: We performed a SCOOT on 36 Sawbones. Eighteen were fixed with TBW, and another 18 with two compression screws. The humeroulnar joint was simulated using an established test setup, which allows the application of triceps traction force through a tendon model to the ulna, while the humeroulnar joint is in a fixed position. Eight models of each fixation group were tested at 20°, and eight at 70° of flexion by isometrical loading until failure, which was defined as either a complete fracture or gap formation of more than 2 mm at the osteotomy site. Results: At 20° of flexion, mean load to failure was similar between the TBW group (1360 ± 238 N) and the compression screw group (1401 ± 261 N) (P = .88). Also, at 70° of flexion, the mean load to failure was similar between the TBW group (1398 ± 215 N) and the compression screw group (1614 ± 427 N) (P = .28). Conclusions: SCOOTs fixed with TBW and compression screws showed similar loads to failure. A SCOOT fixed with compression screws might be a valuable alternative for surgeons when treating intraarticular distal humeral fractures. However, future in vivo studies are necessary to confirm our results in a clinical setting.

12.
Biomater Sci ; 6(9): 2448-2459, 2018 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-30065987

RESUMEN

Advances in biomaterials science and implant surface technology have made dental implants more predictable and implant therapy more attractive to patients. Surgical interventions are becoming less invasive, and patients heal faster and suffer less morbidity. In this preclinical in vivo study, we compared a new ultra-fine grained titanium (ufgTi) implant material with a hydrophilic nano-patterned surface to commercially pure titanium (cpTi) in a well-established animal model. CpTi grade 4 was subjected to Equal Channel Angular Pressing (ECAP), followed by a cold drawing process that provided ultra-fine-grained titanium (ufgTi) with a mean grain size of 300 nm. After metallographic assessment, the surface topography was characterized by laser confocal microscopy and atomic force microscopy. UfgTi and cpTi implants were inserted in the mandible and maxilla of miniature pigs that healed for 4 and for 8 weeks. Osseointegration was assessed by biomechanical torque out analysis, histomorphometric evaluation, and micro-CT analysis. The metallographic properties of UfgTi were significantly better than those of cpTi. Their surface topographies had similar hydrophilic nano-patterned characteristics, with no significant differences in the nanometre range. Histomorphometric and biomechanical torque out analysis revealed no significant differences between ufgTi and cpTi in environments of either low (maxilla) or high (mandible) bone density. We obtained high bone-to-implant contact values irrespective of the bony microarchitecture even when the bone mineral density was low. Overall, this investigation suggests that ufgTi forms a hydrophilic nano-patterned surface with superior metallographic properties compared to cpTi and high levels of osseointegration. Thus, ufgTi has therapeutic potential as a future strategy for the development of small diameter implants to enable less invasive treatment concepts, reduce patient morbidity and may also lower the costs of patient care.


Asunto(s)
Implantes Dentales , Titanio , Animales , Materiales Biocompatibles , Interacciones Hidrofóbicas e Hidrofílicas , Mandíbula , Maxilar , Oseointegración , Propiedades de Superficie , Porcinos , Porcinos Enanos
13.
Vet Comp Orthop Traumatol ; 30(6): 430-437, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29202506

RESUMEN

Objective To study the biomechanical effect of facetectomy in 10 large breed dogs (>24 kg body weight) on the fourth canine cervical functional spinal unit. Methods Canine cervical spines were freed from all muscles. Spines were mounted on a six-degrees-of-freedom spine testing machine for three-dimensional motion analysis. Data were recorded with an optoelectronic motion analysis system. The range of motion was determined in all three primary motions as well as range of motion of coupled motions on the intact specimen, after unilateral and after bilateral facetectomy. Repeated-measures analysis of variance models were used to assess the changes of the biomechanical properties in the three treatment groups considered. Results Facetectomy increased range of motion of primary motions in all directions. Axial rotation was significantly influenced by facetectomy. Coupled motion was not influenced by facetectomy except for lateral bending with coupled motion axial rotation. The coupling factor (coupled motion/primary motion) decreased after facetectomy. Symmetry of motion was influenced by facetectomy in flexion-extension and axial rotation, but not in lateral bending. Clinical Significance Facet joints play a significant role in the stability of the cervical spine and act to maintain spatial integrity. Therefore, cervical spinal treatments requiring a facetectomy should be carefully planned and if an excessive increase in range of motion is expected, complications should be anticipated and reduced via spinal stabilization.


Asunto(s)
Vértebras Cervicales/cirugía , Perros/cirugía , Procedimientos Ortopédicos/veterinaria , Animales , Vértebras Cervicales/fisiología , Perros/fisiología , Rango del Movimiento Articular
14.
Vet Comp Orthop Traumatol ; 30(3): 219-222, 2017 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-28094418

RESUMEN

OBJECTIVES: Atlantoaxial instability has been reported in humans, dogs, equids and ruminants. The functional role of the atlantoaxial ligaments has only been described rudimentarily in equids and ruminants. The goal of the present cadaveric study was to compare the anatomy between the different species and to comparatively assess the role of the stabilizing ligaments of the atlantoaxial joint under sagittal shear loading in canine, equine, and bovine cervical spines. METHODS: Three equine, bovine, and canine cadaveric specimens were investigated. Biomechanical testing was performed using a purpose built shear-testing device driven by a uniaxial servo-hydraulic testing machine. Three cycles in a dorsoventral direction with a constant quasi-static velocity of 0.2 mm/s up to a limiting force of 50 N (canine) or 250 N (bovine, equine), respectively, were performed for each specimen tested. Load and linear displacement were measured by the displacement sensor and load cell of the testing system at a sampling rate of 20 Hz. Tests were performed and the range of motion determined with both intact and transected atlantoaxial ligaments. RESULTS: The range of motion was significantly increased after transection of the ligaments only in the canine specimens. The bovine atlantoaxial joint was biomechanically more stable than in equids. CLINICAL SIGNIFICANCE: Species-specific anatomical and biomechanical differences of the atlantoaxial ligaments in canines, equids, and bovines were detected. The significance of these differences and their impact on the pathogenesis of atlantoaxial subluxations and subsequent treatment remain open questions.


Asunto(s)
Anatomía Comparada , Articulación Atlantoaxoidea/anatomía & histología , Fenómenos Biomecánicos/fisiología , Animales , Cadáver , Bovinos/anatomía & histología , Perros/anatomía & histología , Caballos/anatomía & histología , Humanos , Inestabilidad de la Articulación , Ligamentos , Rango del Movimiento Articular
15.
J Biomed Mater Res B Appl Biomater ; 104(6): 1182-91, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-26097161

RESUMEN

PURPOSE: The purpose of this study was to evaluate the bone formation capability of polyetheretherketone (PEEK) and carbon fiber-reinforced PEEK (CFR-PEEK) implants coated with different titanium and hydroxyapatite plasma-sprayed layers after 2 and 12 weeks. METHODS: In six sheep 108 implants were placed in the pelvis. Altogether six different surface modifications were tested. After 2 and 12 weeks, n = 3 implants per group were examined histologically and n = 6 implants per group were tested by a pull-out test. RESULTS: Biomechanically (p = 0.001) as well as histologically (p > 0.05) surface coating of PEEK/CFR-PEEK led to an increase of osseointegration from 2 to 12 weeks. After 12 weeks, coated implants demonstrated significant (p < 0.001) higher pull-out values in comparison to uncoated implants. Overall, the double coating (titanium bond layer and hydroxyapatite top layer) showed the most favorable results after 2 and 12 weeks. CONCLUSIONS: Plasma-sprayed titanium and hydroxyapatite coatings on PEEK or CFR-PEEK demonstrated a significant improvement of osseointegration. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1182-1191, 2016.


Asunto(s)
Carbono/química , Materiales Biocompatibles Revestidos/química , Durapatita/química , Implantes Experimentales , Cetonas/química , Oseointegración , Polietilenglicoles/química , Ovinos/metabolismo , Animales , Benzofenonas , Proyectos Piloto , Polímeros , Titanio
16.
Acta Biomater ; 30: 116-125, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26577987

RESUMEN

Unrepaired defects in the annulus fibrosus of intervertebral disks are associated with degeneration and persistent back pain. A clinical need exists for a disk repair strategy that can seal annular defects, be easily delivered during surgical procedures, and restore biomechanics with low risk of herniation. Multiple annulus repair strategies were developed using poly(trimethylene carbonate) scaffolds optimized for cell delivery, polyurethane membranes designed to prevent herniation, and fibrin-genipin adhesive tuned to annulus fibrosus shear properties. This three-part study evaluated repair strategies for biomechanical restoration, herniation risk and failure mode in torsion, bending and compression at physiological and hyper-physiological loads using a bovine injury model. Fibrin-genipin hydrogel restored some torsional stiffness, bending ROM and disk height loss, with negligible herniation risk and failure was observed histologically at the fibrin-genipin mid-substance following rigorous loading. Scaffold-based repairs partially restored biomechanics, but had high herniation risk even when stabilized with sutured membranes and failure was observed histologically at the interface between scaffold and fibrin-genipin adhesive. Fibrin-genipin was the simplest annulus fibrosus repair solution evaluated that involved an easily deliverable adhesive that filled irregularly-shaped annular defects and partially restored disk biomechanics with low herniation risk, suggesting further evaluation for disk repair may be warranted. STATEMENT OF SIGNIFICANCE: Lower back pain is the leading cause of global disability and commonly caused by defects and failure of intervertebral disk tissues resulting in herniation and compression of adjacent nerves. Annulus fibrosus repair materials and techniques have not been successful due to the challenging mechanical and chemical microenvironment and the needs to restore biomechanical behaviors and promote healing with negligible herniation risk while being delivered during surgical procedures. This work addressed this challenging biomaterial and clinical problem using novel materials including an adhesive hydrogel, a scaffold capable of cell delivery, and a membrane to prevent herniation. Composite repair strategies were evaluated and optimized in quantitative three-part study that rigorously evaluated disk repair and provided a framework for evaluating alternate repair techniques.


Asunto(s)
Análisis de Falla de Equipo , Hidrogeles/química , Implantes Experimentales , Disco Intervertebral , Falla de Prótesis , Andamios del Tejido/química , Animales , Bovinos , Adhesivo de Tejido de Fibrina/química , Humanos , Degeneración del Disco Intervertebral/cirugía
17.
J Craniomaxillofac Surg ; 43(8): 1589-94, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26297419

RESUMEN

PURPOSE: To compare the initial stability and stability after fatigue of three different locking systems (Synthes(®), Stryker(®) and Medartis(®)) for mandibular fixation and reconstruction. METHOD: Standard mandible locking plates with identical profile height (1,5 mm), comparable length and screws with identical diameter (2,0 mm) were used. Plates were fixed with six screws according a preparation protocol. Four point bending tests were then performed using artificial bone material to compare their initial stability and failure limit under realistic loading conditions. Loading of the plates was performed using of a servo hydraulic driven testing machine. The stiffness of the implant/bone construct was calculated using a linear regression on the experimental data included in a range of applied moment between 2 Nm and 6 Nm. RESULTS: No statistical difference in the elastic stiffness was visible between the three types of plate. However, differences were observed between the systems concerning the maximal load supported. The Stryker and Synthes systems were able to support a significantly higher moment. CONCLUSION: For clinical application all systems show good and reliable results. Practical aspects such as handling, possible angulation of screw fixation, possibility of screw/plate removal, etc. may favour one or the other plating system.


Asunto(s)
Placas Óseas , Mandíbula/cirugía , Reconstrucción Mandibular/instrumentación , Fenómenos Biomecánicos , Tornillos Óseos , Interfase Hueso-Implante/fisiopatología , Módulo de Elasticidad , Diseño de Equipo , Falla de Equipo , Humanos , Ensayo de Materiales , Docilidad , Estrés Mecánico , Propiedades de Superficie
18.
Int J Oral Maxillofac Implants ; 30(6): 1272-9, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26574852

RESUMEN

PURPOSE: The objective of this study was to evaluate stiffness, strength, and failure modes of monolithic crowns produced using computer-aided design/computer-assisted manufacture, which are connected to diverse titanium and zirconia abutments on an implant system with tapered, internal connections. MATERIALS AND METHODS: Twenty monolithic lithium disilicate (LS2) crowns were constructed and loaded on bone level-type implants in a universal testing machine under quasistatic conditions according to DIN ISO 14801. Comparative analysis included a 2 × 2 format: prefabricated titanium abutments using proprietary bonding bases (group A) vs nonproprietary bonding bases (group B), and customized zirconia abutments using proprietary Straumann CARES (group C) vs nonproprietary Astra Atlantis (group D) material. Stiffness and strength were assessed and calculated statistically with the Wilcoxon rank sum test. Cross-sections of each tested group were inspected microscopically. RESULTS: Loaded LS2 crowns, implants, and abutment screws in all tested specimens (groups A, B, C, and D) did not show any visible fractures. For an analysis of titanium abutments (groups A and B), stiffness and strength showed equally high stability. In contrast, proprietary and nonproprietary customized zirconia abutments exhibited statistically significant differences with a mean strength of 366 N (Astra) and 541 N (CARES) (P < .05); as well as a mean stiffness of 884 N/mm (Astra) and 1,751 N/mm (CARES) (P < .05), respectively. Microscopic cross-sections revealed cracks in all zirconia abutments (groups C and D) below the implant shoulder. CONCLUSION: Depending on the abutment design, prefabricated titanium abutment and proprietary customized zirconia implant-abutment connections in conjunction with monolithic LS2 crowns had the best results in this laboratory investigation.


Asunto(s)
Coronas/normas , Pilares Dentales/normas , Diseño de Implante Dental-Pilar/normas , Implantes Dentales/normas , Porcelana Dental , Titanio , Circonio , Fenómenos Biomecánicos , Diseño Asistido por Computadora , Fracaso de la Restauración Dental/estadística & datos numéricos , Análisis del Estrés Dental/métodos , Humanos , Ensayo de Materiales
19.
Clin Implant Dent Relat Res ; 17(6): 1200-7, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24629091

RESUMEN

BACKGROUND: Recent technical development allows the digital manufacturing of monolithic reconstructions with high-performance materials. For implant-supported crowns, the fixation requires an abutment design onto which the reconstruction can be bonded. PURPOSE: The aim of this laboratory investigation was to analyze stiffness, strength, and failure modes of implant-supported, computer-assisted design and computer-aided manufacturing (CAD/CAM)-generated resin nano ceramic (RNC) crowns bonded to three different titanium abutments. MATERIALS AND METHODS: Eighteen monolithic RNC crowns were produced and loaded in a universal testing machine under quasi-static condition according to DIN ISO 14801. With regard to the type of titanium abutment, three groups were defined: (1) prefabricated cementable standard; (2) CAD/CAM-constructed individualized; and (3) novel prefabricated bonding base. Stiffness and strength were measured and analyzed statistically with Wilcoxon rank sum test. Sections of the specimens were examined microscopically. RESULTS: Stiffness demonstrated high stability for all specimens loaded in the physiological loading range with means and standard deviations of 1,579 ± 120 N/mm (group A), 1,733 ± 89 N/mm (group B), and 1,704 ± 162 N/mm (group C). Mean strength of the novel prefabricated bonding base (group C) was 17% lower than of the two other groups. Plastic deformations were detectable for all implant-abutment crown connections. CONCLUSIONS: Monolithic implant crowns made of RNC seem to represent a feasible and stable prosthetic construction under laboratory testing conditions with strength higher than the average occlusal force, independent of the different abutment designs used in this investigation.


Asunto(s)
Coronas , Diseño de Implante Dental-Pilar , Prótesis Dental de Soporte Implantado , Cerámica , Resinas Compuestas , Diseño Asistido por Computadora , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Técnicas In Vitro
20.
Clin Biomech (Bristol, Avon) ; 30(10): 1043-8, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26443882

RESUMEN

BACKGROUND: Trans-olecranon chevron osteotomies (COs) remain the gold standard surgical approach to type C fractures of the distal humerus. This technique is associated with a high complication rate and development of an extra-articular olecranon osteotomy may be advantageous. The aim of this study was to compare the load to failure of COs with extra-articular oblique osteotomies (OOs) as well as modified, extra-articular step osteotomies (SOs). METHODS: These three osteotomies and their subsequent fixation utilizing a standardized tension band wiring technique were tested in 42 composite analog ulnae models at 20° and 70° of flexion. Triceps loading was simulated with a servo hydraulic testing machine. All specimens were isometrically loaded until failure. Kinematic and force data, as well as interfragmentary motion were recorded. RESULTS: At 70°, CO failed at a mean load of 963 N (SD 104 N), the OO at 1512 N (SD 208 N) and the SO at 1484 N (SD 153 N), (P<0.001). At 20°, CO failed at a mean load of 707 N (SD 104 N) and OO at 1009 N (SD 85 N) (P=0.006). The highest load to failure was observed for the SO, which was 1277 N (SD 172 N). The load to failure of the SO was significantly higher than the CO as well as the OO. CONCLUSION: Extra-articular osteotomies showed a significantly higher load to failure in comparison to traditional CO. At near full extension (20° of flexion), this biomechanical advantage was further enhanced by a step-cut modification of the extra-articular oblique osteotomy.


Asunto(s)
Fijación Interna de Fracturas/métodos , Fracturas del Húmero/cirugía , Olécranon/cirugía , Osteotomía/métodos , Cúbito/lesiones , Fenómenos Biomecánicos , Articulación del Codo/fisiopatología , Articulación del Codo/cirugía , Análisis de Falla de Equipo , Humanos , Fracturas del Húmero/fisiopatología , Modelos Biológicos , Estrés Mecánico , Resistencia a la Tracción/fisiología , Cúbito/fisiopatología , Cúbito/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA