Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Acta Neurochir (Wien) ; 160(12): 2489-2500, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30413938

RESUMEN

BACKGROUND: Stereoelectroencephalography (SEEG) is an effective technique to help to locate and to delimit the epileptogenic area and/or to define relationships with functional cortical areas. We intend to describe the surgical technique and verify the accuracy, safety, and effectiveness of robot-assisted SEEG in a newly created SEEG program in a pediatric center. We focus on the technical difficulties encountered at the early stages of this program. METHODS: We prospectively collected SEEG indication, intraoperative events, accuracy calculated by fusion of postoperative CT with preoperative planning, complications, and usefulness of SEEG in terms of answering preimplantation hypothesis. RESULTS: Fourteen patients between the ages of 5 and 18 years old (mean 10 years) with drug-resistant epilepsy were operated on between April 2016 and April 2018. One hundred sixty-four electrodes were implanted in total. The median entry point localization error (EPLE) was 1.57 mm (1-2.25 mm) and the median target point localization error (TPLE) was 1.77 mm (1.2-2.6 mm). We recorded seven intraoperative technical issues. Two patients suffered complications: meningitis without demonstrated germ in one patient and a right frontal hematoma in the other. In all cases, the SEEG was useful for the therapeutic decision-making. CONCLUSION: SEEG has been useful for decision-making in all our pediatric patients. The robotic arm is an accurate tool for the insertion of the deep electrodes. Nevertheless, it is an invasive technique not risk-free and many problems can appear at the beginning of a robotic arm-assisted SEEG program that must be taken into account beforehand.


Asunto(s)
Epilepsia Refractaria/cirugía , Electroencefalografía/métodos , Complicaciones Posoperatorias/epidemiología , Robótica/métodos , Técnicas Estereotáxicas/efectos adversos , Adolescente , Niño , Preescolar , Toma de Decisiones Clínicas , Epilepsia Refractaria/diagnóstico , Electrodos Implantados/efectos adversos , Electrodos Implantados/normas , Electroencefalografía/efectos adversos , Electroencefalografía/instrumentación , Electroencefalografía/normas , Femenino , Humanos , Masculino , Robótica/instrumentación , Robótica/normas , Técnicas Estereotáxicas/instrumentación , Técnicas Estereotáxicas/normas
2.
Neurocirugia (Astur : Engl Ed) ; 30(2): 87-93, 2019.
Artículo en Inglés, Español | MEDLINE | ID: mdl-29625853

RESUMEN

Microsurgical clipping is still regarded as the gold-standard treatment for broad-neck intracranial aneurysms. New endovascular techniques like balloon or stent assisted coiling are quickly rising to the challenge and showing promising outcomes. As a result, broad-neck aneurysms are increasingly addressed by these techniques despite they have not been tested against clipping in a randomized controlled trial and long-term complications might be unknown yet. Intraprocedural coil migration has been well documented in the literature, but the same complication in a delayed fashion is scarcely reported. We present a case of delayed coil migration occurring after a balloon-assisted embolization of a wide-necked intracranial aneurysm and we perform a literature review for similar cases. We discuss how, despite seeming an extremely rare complication, with new endovascular techniques increasingly perceived as the safer option in any aneurysm, potential adverse events may become more frequent. Strategies proposed to address this developing scenario are also reviewed.


Asunto(s)
Arterias Cerebrales/diagnóstico por imagen , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/instrumentación , Migración de Cuerpo Extraño/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA