Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
3D Print Med ; 10(1): 26, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39102099

RESUMEN

BACKGROUND: . Mitral transcatheter edge-to-edge repair (m-TEER) is a minimally invasive procedure for treating mitral regurgitation (MR). m-TEER is a highly technical procedure, and a steep learning curve needs to be overcome for operators to ensure optimal patient outcomes and minimise procedural complications. Training via online simulation and observation of procedures is not sufficient to establish operator confidence; thus, advanced hands-on training modalities need to be explored and developed. METHODS: . In this study, a novel anatomical simulator for m-TEER training was evaluated in comparison to a standard model. The proposed simulator resembled the anatomical features of the right and left atrium, left ventricle and mitral valve apparatus. Participants in the questionnaire (n = 18) were recruited across 4 centres in London with (n = 8) and without (n = 10) prior experience in m-TEER. Participants were asked to simulate procedures on both an idealised, routinely used simulator and the newly proposed anatomical model. The questionnaire was designed to assess (i) participants' confidence before and after training and (ii) the realism of the model in the context of the m-TEER procedure. The results of the questionnaires were collected, and statistical analysis (t-test) was performed. RESULTS: . Both models were equally beneficial in increasing operator confidence before and after the simulation of the intervention (P = 0.43). However, increased confidence after training with the anatomical model was recorded (P = 0.02). Participants with prior experience with m-TEER therapy were significantly more confident about the procedure after training with the anatomical model than participants who had no prior experience (P = 0.002). On average, all participants thought that the anatomical model was effective as a training simulator (P = 0.013) and should be integrated into routine training (P = 0.015)). Participants with experience thought that the anatomical model was more effective at reproducing the m-TEER procedure than the idealised model (P = 0.03). CONCLUSIONS: . This study showed how a more realistic simulator can be used to improve the effectiveness of m-TEER procedural training. Such pilot results suggest planning future and large investigations to evaluate improvements in clinical practice.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA