Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 107
Filtrar
Más filtros

Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Esthet Restor Dent ; 36(2): 303-323, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37571973

RESUMEN

OBJECTIVE: To assess and compare, through a systematic review of the literature, the biomechanical performance of endocrowns and traditional core-crowns (with and without intracanal post) for the rehabilitation of endodontically treated teeth with severe coronal structure damage. MATERIALS AND METHODS: A systematic search was performed in MEDLINE/PubMed, Scopus, and Web of Science databases. In-vitro studies comparing endocrowns with (post-)core-crown restorations were selected and screened by two independent reviewers. The included studies were submitted to the risk of bias analysis using the RoBDEMAT tool and the biomechanical outcomes were collected for qualitative analysis. The extracted data were presented based on comparative analyses among the included studies. RESULTS: Thirty-one studies were included: 9 studies evaluated restorations of molars, 14 for premolars, and 8 studies evaluated anterior restorations. For the majority of the studies, endocrowns showed either similar or greater survival rates under fatigue and monotonic load than (post-)core-crown restorations, irrespectively of the tooth. The endocrowns showed more favorable failure patterns than (post-)core-crowns, irrespectively of the tooth. Endocrowns produced lower stresses in the restorative material for molars and premolars and in the luting material for premolars than (post-)core-crown restorations. The included studies presented adequate information for most items of the RoBDEMAT risk of bias tool. CONCLUSION: Endocrowns showed similar or greater biomechanical performance than the traditional (post-)core-crown restorations in most of the evaluated studies. CLINICAL SIGNIFICANCE: This systematic review showed that endocrowns present either similar or greater biomechanical performance than core-crown restorations for anterior and posterior endodontically treated teeth with severe structural damage.


Asunto(s)
Coronas , Diente no Vital , Humanos , Materiales Dentales , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Ensayo de Materiales , Diente no Vital/terapia , Prostodoncia/métodos
2.
J Prosthodont ; 33(4): 396-401, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37300878

RESUMEN

PURPOSE: To assess the effect of preheating resin-based materials and ultrasound application on the failure load of a lithium disilicate glass-ceramic. MATERIALS AND METHODS: Ninety ceramic specimens were produced (14×12×1.0 mm) and divided into 9 groups (n = 10) to be bonded to a dentin analog (Nema G10) with light-cured luting agent (LC), flowable resin composite (FL), and supra-nano filled resin composite (SN), as follows: LC/R - LC at room temperature; LC/P - preheated LC; LC/P/U - preheated LC and Ultrasound; FL/R - FL at room temperature; FL/P - preheated FL; FL/P/U - preheated FL and Ultrasound; SN/R - SN at room temperature; SN/P - preheated SN; SN/P/U - preheated SN and Ultrasound. The failure load test was performed in a universal testing machine with the aid of acoustic detection. The data was analyzed with two-way ANOVA (for failure load) and Weibull statistics (Weibull modulus - m and characteristic strength, based on 95% confidence intervals - CI). RESULTS: The analyses of failure load revealed no statistically significant difference among groups considering the type of luting agent (P = 0.075; F = 2,673), the application method (P = 0.772; F = 2,259), and the interaction between them (P = 0.297; F = 1,248). The characteristic strength did not show differences among groups (95% CI). The m, which indicates structural reliability, showed lower values for SN/P/U and SN/P, with a difference from other selected groups (95% CI). CONCLUSION: Preheating of resin-based materials and ultrasound application did not affect the failure load of lithium disilicate glass-ceramic. Lower reliability was observed with supra-nano filled resin composite.


Asunto(s)
Cerámica , Porcelana Dental , Reproducibilidad de los Resultados , Ensayo de Materiales , Porcelana Dental/química , Cerámica/química , Cementos de Resina/uso terapéutico , Cementos de Resina/química , Cementos Dentales , Propiedades de Superficie
3.
J Esthet Restor Dent ; 35(6): 860-868, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37209028

RESUMEN

OBJECTIVE: the aim of this study was to evaluate the effect of resin composite layering on discolored substrates to obtain masking ability with monolithic ceramics. MATERIALS AND METHODS: Four groups (n = 8) of computer-aided design/computer aided manufacturing (CAD/CAM) monolithic ceramics, shade A1, with thicknesses of 1.0 and 1.5 mm, were tested: feldspathic (FC), leucite-reinforced (LC), lithium disilicate-reinforced (LD), and translucent zirconia (5YSZ). Five substrates were used: A1 (used as reference), A3.5, C4, and coppery and silvery metals. The substrates were separated as non-layered or layered (with flowable opaque resin composite (FL), white opaque restorative resin composite (WD), and A1-shaded opaque restorative resin composite (A1D)). Resin composite layers of 0.5 and 1.0 mm were tested. The try-in paste, shade A1, was used as a luting agent. Translucency parameter (TP00 ) was assessed for the ceramics. Color differences (∆E00 ) were assessed for the restorative ceramics and resin composite layers over discolored substrates with the CIEDE2000 formula. The results were compared statistically, and descriptively with acceptability (AT, 1.77) and perceptibility (PT, 0.81) thresholds. RESULTS: Feldspathic showed the highest TP00 (for both ceramic thicknesses) and LD the lowest (for 1.5 mm of ceramic thickness) (P < 0.001). For substrate A3.5, layering with 1.0 mm of A1D or WD ensured ∆E00 below PT for all ceramics tested (P < 0.001). The use of 0.5 mm of FL or 1.0 mm of A1D associated with ceramics LC, LD, and 5YSZ ensured ∆E00 below AT for substrates C4 and coppery metal (P < 0.001). Silvery background layered with 0.5 mm of FL presented ∆E00 below AT for all ceramics and ∆E00 below PT for lithium disilicate of 1.0 mm of thickness (∆E00 = 0.72). CONCLUSIONS: Layering severely discolored substrates with selected opaque resin composites ensures masking ability for restoration with CAD/CAM monolithic ceramics. CLINICAL SIGNIFICANCE: Severely discolored substrates are predictably restored with monolithic CAD/CAM ceramics by performing a previous layering of the substrate with opaque resin composite.


Asunto(s)
Cerámica , Porcelana Dental , Color , Cementos Dentales , Diseño Asistido por Computadora , Ensayo de Materiales , Propiedades de Superficie
4.
J Prosthet Dent ; 130(3): 392.e1-392.e9, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37516645

RESUMEN

STATEMENT OF PROBLEM: The color of monolithic zirconia restorations is obtained by presintering or postsintering coloring techniques. However, studies on the differences in surface characteristics and their influence on color stability are lacking. PURPOSE: The purpose of this in vitro study was to evaluate the influence of shading and staining techniques for a zirconia ceramic on the surface characteristics and colorimetric parameters (color difference, translucency, and whiteness index) after exposure to coffee or red wine and then polishing. MATERIAL AND METHODS: Ceramic disks (N=30; Ø10×1mm) were allocated into 3 groups: preshaded-shaded by the manufacturer (IPS e.max ZirCAD MT, shade A2); manually shaded-unshaded zirconia (IPS e.max ZirCAD MT, bleaching shade-BL) colored by the brushing technique, before sintering; stained-unshaded zirconia (IPS e.max ZirCAD MT BL) colored by the staining technique, after sintering. Spectrophotometric color assessments ensured the same initial perceived color (Vita Classical A2) for specimens included in the study (∆E00<1.77 acceptability threshold). Surface characteristics were assessed by scanning electron microscopy and atomic force microscopy. The specimens were immersed in coffee (n=5) or red wine (n=5) for 12 and 24 days and subsequently polished. The data were statistically and descriptively analyzed for color differences (∆E00), translucency parameters (TP00), and whiteness indexes for dentistry (WID), considering acceptability and perceptibility thresholds. RESULTS: The shaded groups found an irregular ceramic surface with uniformly sized zirconia crystals. The stained group found a glass-covered smoother surface. Significant alterations in color parameters (∆E00, TP00, WID) were observed with immersion in pigmenting beverages (P<.001) both after 12 days, and after 24 days. The shaded specimens had greater color alterations after immersion but benefited from the polishing procedure, which reduced color differences below an acceptable threshold in comparison with the baseline. Stained specimens had lower color alterations after immersion, but the polishing protocol was detrimental as it whitened the ceramic by subsurface exposure. CONCLUSIONS: The coloring technique influences the surface characteristics of zirconia ceramic and also the color parameters after exposure to colored beverages and polishing.


Asunto(s)
Cerámica , Café , Color , Ensayo de Materiales , Propiedades de Superficie , Cerámica/química , Circonio/química , Porcelana Dental
5.
J Prosthet Dent ; 2022 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-36535881

RESUMEN

STATEMENT OF THE PROBLEM: Biological complications of implant-supported prostheses remain a concern. Therefore, standardizing hygiene protocols to promote their maintenance is important. PURPOSE: The purpose of this scoping review was to identify available hygiene guidance for home care procedures, as well as periodicity and protocols for the professional maintenance of implant-supported prostheses. MATERIAL AND METHODS: This study was based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, and the study protocol was made available at: https://osf.io/5jdeh/. The search was last performed in the PubMed database on March 15, 2022 and was undertaken by 2 independent researchers. Clinical studies and reviews that evaluated home care and maintenance protocols for dental implant-supported prostheses (fixed or removable), without language restriction or year of publication, were included. A descriptive analysis was performed considering study characteristics (study design, restorative assembly, maintenance strategies, eligibility criteria, number of included studies, quality/level of evidence, and main findings). RESULTS: The initial search yielded 3138 studies, of which 18 were included for descriptive analysis (6 critical reviews, 4 clinical trials, 3 systematic reviews, 2 guideline reports, 2 retrospective studies, and 1 transversal study). The main instrument recommended for home care was the use of a conventional toothbrush associated with triclosan-containing toothpaste in addition to interproximal aids (brushes or floss) for all types of restorations. The use of irrigation instruments was also frequently considered. For professional maintenance, almost all studies reported a positive effect of regular recalls every 3 months during the first year, followed by less regular recalls according to the motivation of the patient and home care efficacy. At each recall, the professional should evaluate the patient history, oral tissues, implant, abutments, and restorations, as well as perform professional cleaning of the prostheses with appropriate instruments so that the implants and abutments may be preserved. CONCLUSIONS: Establishing an adequate hygiene protocol is indispensable for implant-supported restorations. To do so, the professional must guide and support the patient's home care by taking into account the patient's motivation and efficacy during the hygiene procedures. Also, for professional maintenance, the periodicity of recalls should be constant and include an evaluation of the condition of the restoration and adjacent tissues, followed by professional cleaning of prostheses, implants, and abutments, in addition to new instructions to improve patient home care.

6.
J Prosthet Dent ; 2022 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-35527069

RESUMEN

STATEMENT OF PROBLEM: How best to restore endodontically treated teeth is still unclear because many types of material and techniques are involved. PURPOSE: The purpose of this overview of systematic reviews of clinical studies was to assess the available evidence-based literature on the influence of associated clinical factors on the clinical performance (survival, failure rate, or success) of restored endodontically treated teeth. MATERIAL AND METHODS: PubMed, Scopus, and Web of Science were searched from inception until September 27, 2021, to identify systematic reviews. Two reviewers independently screened titles, abstracts, and full-text articles, and each reviewer extracted the data of half of the included studies. A single reviewer with an independent verifier completed the quality appraisal. A descriptive analysis of the collected data was made. RESULTS: A total of 36 systematic reviews fulfilled the inclusion criteria. The factors most assessed were the type of coronal restorative technique (n=22) and type of post (n=22). The results indicated that metal and fiber posts seem to present similar clinical performance, endocrowns could be a suitable restorative option, there is no evidence to confirm whether single crowns are better or worse than direct restoration, the maintenance of the coronal structure is a fundamental factor, and the ferrule effect is still a controversial topic. Most of the studies (n=30, 81%) presented a final Grading of Recommendations, Assessment, Development and Evaluations (GRADE) rating of "critically low." CONCLUSIONS: The post type does not appear to influence the clinical performance of restored endodontically treated teeth. However, conclusive evidence to suggest how different materials or techniques for restoring coronal tooth structure affect the clinical performance of such restorations, as well as the impact of the ferrule effect, is still lacking.

7.
J Prosthet Dent ; 2022 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-36202633

RESUMEN

STATEMENT OF PROBLEM: Preheated composite resin and adhesive coating have been recommended as luting agents for ceramic veneers; however, information about the mechanical behavior of feldspathic porcelain veneers after using these methods is still limited. PURPOSE: The purpose of this in vitro study was to evaluate the influence of the use of preheated composite resin or an adhesive resin layer on the strengthening of a feldspathic porcelain. MATERIAL AND METHODS: Feldspathic porcelain disks were fabricated (N=210), etched (10% hydrofluoric acid for 90 seconds), and bonded according to resin-based luting agents (30 per group) for the biaxial flexural strength tests: photopolymerized resin cement, flowable composite resin, preheated composite resin, with or without previous adhesive coating. Characteristic strength and Weibull modulus were calculated. The viscosity of the luting agents was measured by using isothermal analyses. Finite element analysis simulated the flexural test. Fractographic and bonded interfaces were observed. RESULTS: The use of preheated composite resin led to the lowest stress levels in the feldspathic porcelain veneers. However, it did not increase the ceramic strengthening compared with other luting agents, as higher values were observed with flowable composite resin (P<.05). The use of an adhesive resin layer had no significant effect on ceramic strengthening when associated with preheated composite resin or resin cement (P>.05). Preheated composite resin presented the highest viscosity and led to incomplete filling of the porcelain surface irregularities. Failures originated on the ceramic surface subjected to tensile stress and were typically associated with pores at the ceramic-luting agent interface. CONCLUSIONS: The use of preheated composite resin or an adhesive resin layer did not have a positive effect on strengthening feldspathic porcelain.

8.
J Prosthet Dent ; 128(3): 496.e1-496.e8, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35985853

RESUMEN

STATEMENT OF PROBLEM: Information regarding the masking ability of ceramic crowns over different implant abutment materials is scarce. PURPOSE: The purpose of this in vitro study was to evaluate the masking ability of different monolithic or bilayer ceramic materials with different thicknesses over substrates indicated for implant restorations by using opaque and translucent evaluation pastes. MATERIAL AND METHODS: Disk-shaped specimens, shade A1 (VITA Classic; Ø10×1.5 to 2.5 mm), of different ceramics (a bilayer system [yttria-stabilized zirconia infrastructure+porcelain veneer: Zir+Pc] and monolithic systems [lithium disilicate under low, medium, or high translucency: LtLD, MtLD, or HtLD, respectively, and a high-translucent yttria-stabilized zirconia: HtZir]) were made (n=4). The color difference (ΔE00) was assessed by using the CIEDE2000 formula and considering the different ceramic systems over 5 implant abutment materials (A1 shade Zir [Zir A1]; white Zir [White Zir]; A1 low-translucency lithium disilicate [LD]; polyetheretherketone [PEEK]; and titanium [Ti]) when using 2 different evaluation pastes (translucent or opaque). The control comparison was the restorative material positioned over the Zir A1 substrate with a translucent evaluation paste. Statistical analysis was made by using a 2-way ANOVA and Tukey post hoc tests (α=.05) for ΔE00 data considering the restorative material and luting agent factors as their association. Additionally, ΔE00 data were qualitatively analyzed considering the acceptability and perceptibility thresholds. The translucency parameter (TP00) of each restorative material was evaluated, and data were submitted to 1-way ANOVA and Tukey post hoc tests (α=.05). RESULTS: The most predictable masking ability was seen with Zir+Pc regardless of the evaluation paste used. Nevertheless, under 1.5-mm thickness, Zir+Pc did not adequately mask Ti (ΔE00>1.77). Most monolithic ceramics did not mask discolored substrates (PEEK or Ti, ΔE00>1.77). The exception was HtZir, which presented acceptable masking ability over PEEK at 2.5-mm thickness with both evaluation pastes (ΔE00<1.77). Regardless of the restorative material thickness, Zir+Pc showed the lowest (P<.05) TP00 values (TP00=3.45 at 1.5-mm thickness; TP00=2.00 at 2.5-mm thickness), and HtLD presented the highest (P<.05, TP00=23.50 at 1.5-mm thickness; TP00=13.36 at 2.5-mm thickness). HtZir showed similar TP00 to MtLD at 1.5-mm thickness and similar TP00 to Zir+Pc when used at 2.5-mm thickness (P>.05). CONCLUSIONS: Monolithic ceramics should be used with caution over discolored implant abutments. Bilayer systems (Zir+Pc) were the most predictable approach to adequately masking discolored substrates such as PEEK or Ti. An increased restoration thickness provided higher masking ability for all restorative materials tested.


Asunto(s)
Implantes Dentales , Porcelana Dental , Benzofenonas , Cerámica/uso terapéutico , Color , Coronas , Cementos Dentales , Materiales Dentales , Ensayo de Materiales , Polímeros , Propiedades de Superficie , Titanio , Itrio , Circonio
9.
J Prosthet Dent ; 128(6): 1335.e1-1335.e8, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36404161

RESUMEN

STATEMENT OF PROBLEM: Zirconia has been reported to be suitable for multiunit monolithic restorations. However, as the connector region is the weakest part of the system, studies are needed to determine the optimal connector geometry. PURPOSE: The purpose of this in vitro study was to evaluate the load-bearing capacity under fatigue of implant-supported fixed partial prostheses made of monolithic zirconia with different connector cross-sectional geometries. MATERIAL AND METHODS: Three-unit monolithic fixed partial prostheses (from mandibular second premolar to the second molar) were fabricated in zirconia (Zenostar T) by computer-aided design and computer-aided manufacture (CAD-CAM). Different connector cross-sectional geometries, with an area of 9 mm2, were tested (n=10): round, square with rounded angles, or trapezoid with rounded angles. The prostheses were screwed over 2 implants and inserted into acrylic resin bases. The specimens were submitted to a mechanical fatigue test until failure, with load applied to the pontic using the stepwise stress methodology (initial load of 100 N for 5000 cycles, followed by an increase to 200 N for 20 000 cycles, with a subsequent increase of 50 N each step). For data analysis, fatigue failure load (FFL) and cycles for fatigue failure (CFF) were recorded. Failed structures were analyzed by fractography. The Kaplan-Meier test followed by a log-rank Mantel-Cox post hoc test was used to analyze FFL and CFF (α=.05). Weibull analysis was also performed. RESULTS: The round (1065 N) and trapezoid (1010 N) groups presented higher FFL values than the square one (870 N) (P≤.05). For CFF, the round connector (358 777) was better than the square (280 310) (P=.006), and the trapezoid (337 773) was statistically similar to both (P>.05). No difference among groups was observed in Weibull modulus either for CFF or FFL data. All failures were catastrophic, originating at the base of the connector and propagating toward the occlusal surface of the pontic (region under loading). CONCLUSIONS: The connector cross-sectional geometry significantly influenced the mechanical fatigue performance of implant-supported fixed partial prostheses made of monolithic zirconia.


Asunto(s)
Cerámica , Implantes Dentales , Cerámica/química , Análisis del Estrés Dental , Ensayo de Materiales , Propiedades de Superficie , Circonio/química , Diseño Asistido por Computadora , Soporte de Peso , Fracaso de la Restauración Dental , Porcelana Dental/química
10.
J Esthet Restor Dent ; 33(7): 1017-1028, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34105868

RESUMEN

OBJECTIVE: To evaluate the effect of surface treatments on optical, colorimetric, and surface characteristics of lithium disilicate glass-ceramic. MATERIALS AND METHODS: Specimens (n = 5, IPS e.max CAD) were randomly allocated to the following treatments: mirror-polished: SiC papers; as-cut: mimicking CAD-CAM milling; ground: 90-120 µm-grit diamond bur; ground polished: ground, finished (46-30 µm-grit diamond bur), polished (diamond cups, brush and diamond paste); ground glazed: ground, glazed; ground polished glazed: association of methods. CIELAB color coordinates were obtained by a spectrophotometer. CIEDE2000 color differences (ΔE00 ) and the translucency parameter (TP00 ) were calculated. Light transmittance was assessed with a colorimeter. Surface characteristics (topography and roughness) were analyzed. Statistical differences for each condition and outcome were detected using one-way ANOVA with Tukey's post-hoc test (α = 0.05). RESULTS: TP00 data show statistical reduction after grinding (p < 0.05), which was only restored with polishing (solely or with glazing). ΔE00 shows that grinding results in perceptible variations in color (above 0.81), which were restored after all post-processing protocols (exception to only glaze application in contact with a black background). Light transmittance data corroborated such performance. Polishing and glazing reduced roughness and improved surface topography. CONCLUSION: Grinding statistically increased roughness, reduced translucency, light transmittance through the ceramic, and resulted on color differences. On contrary, polishing (followed or not by glazing) reduced roughness and enhanced ceramic translucency and light transmittance. Glaze also reduced roughness, but it still presented reduced translucency. The positioning (facing up or down) of the ceramic treated surface influenced the considered outcomes. CLINICAL SIGNIFICANCE: Grinding with diamond burs results in a deleterious impact to the optical, colorimetric and surface characteristics of lithium disilicate ceramic. Thus, polishing (followed or not by glazing) is recommended for optical and topographical enhancements when lithium disilicate monolithic restorations require occlusal adjustments.


Asunto(s)
Colorimetría , Pulido Dental , Cerámica , Porcelana Dental , Ensayo de Materiales , Propiedades de Superficie
11.
J Prosthet Dent ; 126(1): 128.e1-128.e6, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34052029

RESUMEN

STATEMENT OF PROBLEM: Severely discolored substrates have been shown to limit the use of computer-aided design and computer-aided manufacturing (CAD-CAM) ceramic blocks because they provide insufficient color masking. PURPOSE: The purpose of the in vitro study was to evaluate the effect of a layer of high-value opaque composite resin over discolored substrates to determine its masking ability with CAD-CAM ceramics. MATERIAL AND METHODS: Six ceramic groups (n=10) were tested. A bilayer group of zirconia and porcelain served as the control. The CAD-CAM monolithic groups were translucent zirconia, zirconia-reinforced lithium silicate, lithium disilicate, leucite-reinforced glass-ceramic, and feldspathic ceramic. Five substrates were used: A1 (used as reference), A3.5, C4, and coppery and silvery metals. The substrates were separated as nonlayered or layered (with flowable or restorative opaque composite resins). The tested luting agents were white, opaque, and A1. Color differences (ΔE00) were assessed with the CIEDE2000 formula. A 2-way ANOVA (α=.05) was used to detect significant differences in ΔE00 among the groups for each substrate. The results were compared with acceptability (1.77) and perceptibility (0.81) thresholds. RESULTS: The flowable composite resin layer associated with A1 luting agent ensured ΔE00 lesser the than perceptibility thresholdwith the use of CAD-CAM monolithic ceramics, with the lowest values for zirconia-reinforced lithium silicate in substrates A3.5 (0.53) and C4 (0.32) and for leucite-reinforced glass-ceramic for coppery (0.49) and silvery (0.81) substrates (P<.001). The same benefit was observed when zirconia and porcelain was tested over the silvery substrate. The absence of substrate treatment only provided ΔE00 lesser than the acceptability threshold with CAD-CAM ceramics for the A3.5 background. CONCLUSIONS: The application of a flowable opaque composite resin and the use of a shaded luting agent ensure masking with CAD-CAM monolithic ceramics.


Asunto(s)
Cerámica , Porcelana Dental , Color , Diseño Asistido por Computadora , Ensayo de Materiales , Propiedades de Superficie
12.
J Prosthet Dent ; 126(4): 489-489.e5, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32981715

RESUMEN

STATEMENT OF PROBLEM: The best protocol to restore endodontically treated teeth is still unclear, with many factors to be considered, including the selection and necessity of a post, the type of coronal restoration, the amount of remaining coronal structure, and the type of luting agent. PURPOSE: The purpose of this systematic review was to assess the restorative preferences for endodontically treated teeth between dentists and dental students. MATERIAL AND METHODS: Survey studies, written in English, of dentists and dental students, which evaluated the use of intracanal posts and other restorative options for endodontically treated teeth, were selected. Searches were performed in the PubMed and SCOPUS databases without time restriction. Screening and data extraction were performed by 2 researchers independently. A standardized outline was used to extract the data (questions related to the theme and the response rate of each question on the survey), and the risk of bias was assessed. Descriptive analysis was performed of the collected information. RESULTS: Twenty-five articles were included. Most dentists who answered the surveys reported the time since graduation as 1 to 20 years (40%), and 44% were specialists. The most reported choices concerning the type of posts used were prefabricated posts (45.8%), cast metal posts (16.7%), and both posts (16.7%). The cast metal posts were cited more frequently in surveys published between 1994 and 2010, whereas prefabricated posts, both metal and glass fiber ones, were cited between 2006 and 2019. The preferred luting agent for intracanal posts was resin-based (47%). These choices seem to have been influenced by time and by the level of postgraduate training. CONCLUSIONS: Restorative preferences related to posts have changed over time, from the use of cast posts to prefabricated ones or the use of both posts and seem to be influenced by experience and postgraduate training.


Asunto(s)
Técnica de Perno Muñón , Diente no Vital , Resinas Compuestas , Coronas , Odontólogos , Humanos , Estudiantes
13.
J Prosthet Dent ; 125(1): 117-125, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32057485

RESUMEN

STATEMENT OF PROBLEM: The mechanical behavior of ceramic endocrowns is unclear. PURPOSE: The purpose of this in vitro and 3-dimensional finite element analysis (3D-FEA) study was to evaluate the mechanical behavior of endodontically treated teeth restored with ceramic endocrowns made by using different computer-aided design and computer-aided manufacturing (CAD-CAM) systems. MATERIAL AND METHODS: Sixty mandibular human molars were endodontically treated, prepared for endocrowns, and divided into 4 groups (n=15) according to the following various ceramic systems: leucite-based glass-ceramic (LC group), lithium disilicate-based glass-ceramic (LD group), glass-ceramic based on zirconia-reinforced lithium silicate (LSZ group), and monolithic zirconia (ZR group). After adhesive bonding, the specimens were subjected to thermomechanical loading and then to fracture resistance testing in a universal testing machine. The failure mode of the specimens was qualitatively evaluated. Three-dimensional FEA was performed to evaluate the stress distribution in each group. Data were analyzed by using a 1-way ANOVA and the Tukey HSD test (α=.05). RESULTS: Statistically significant differences among the groups were observed (P<.05). The outcomes of the LC, LD, and LSZ groups were similar (1178 N, 1935 N, and 1859 N) but different from those of the ZR group (6333 N). The LC and LD groups had a higher ratio of restorable failures, while LSZ and ZR had more nonrestorable failures. Fractographic analysis indicated a regular failure pattern in the ZR group and irregular failure patterns in the other groups. Three-dimensional FEA revealed similar values and stress pattern distributions among the groups. CONCLUSIONS: The mechanical performance of monolithic zirconia was better than that of the other ceramic endocrowns considered in this research; however, monolithic zirconia presented a higher rate of catastrophic tooth structure failure.


Asunto(s)
Coronas , Fracaso de la Restauración Dental , Cerámica , Diseño Asistido por Computadora , Porcelana Dental , Análisis del Estrés Dental , Humanos , Ensayo de Materiales
14.
J Prosthet Dent ; 126(1): 119-127, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32636073

RESUMEN

STATEMENT OF PROBLEM: Data comparing the fatigue performance of adhesively luted glass or polycrystalline ceramic systems for computer-aided design and computer-aided manufacturing (CAD-CAM) are scarce. PURPOSE: The purpose of this in vitro study was to evaluate and compare the fatigue performance of monolithic crowns manufactured from glass or polycrystalline CAD-CAM ceramic systems adhesively luted to a dentin analog. MATERIALS AND METHODS: Fifty-four pairs of standardized preparations of dentin analog (NEMA Grade G10) and simplified ceramic crowns of 1.5-mm thickness were obtained with 3 ceramic materials: lithium disilicate (LD) glass-ceramic (IPS e.max CAD); zirconia-reinforced lithium silicate (ZLS) glass-ceramic (Vita Suprinity); and translucent yttrium fully stabilized polycrystalline zirconia (Trans YZ) (Prettau Anterior). The simplified crowns (n=15) were adhesively cemented onto the preparations and subjected to step-stress fatigue test (initial load of 400 N, 20 Hz, 10 000 cycles, followed by 100-N increment steps until failure). Collected data (fatigue failure load [FFL] and cycles for failure [CFF]) were submitted to survival analysis with the Kaplan-Meier and Mantel-Cox post hoc tests (α=.05) and to Weibull analysis (Weibull modulus and its respective 95% confidence interval). Failed crowns were submitted to fractography analysis. The surface characteristics of the internal surface (roughness, fractal dimension) of additional crowns were accessed, and the occlusal cement thickness obtained in each luted system was measured. RESULTS: Trans YZ crowns presented the highest values of FFL, CFF, and survival rates, followed by ZLS and LD (mean FFL: 1740 N>1187 N>987 N; mean CFF: 149 000>92 613>73 667). Weibull modulus and cement thickness were similar for all tested materials. LD presented the roughest internal surface, followed by ZLS (mean Ra: 226 nm>169 nm>93 nm). The LD and ZLS internal surfaces also showed higher fractal dimension, pointing to a more complex surface topography (mean fractal dimension: 2.242=2.238>2.147). CONCLUSIONS: CAD-CAM monolithic crowns of Trans YZ show the best fatigue performance. In addition, ZLS crowns also showed better performance than LD crowns.


Asunto(s)
Cerámica , Porcelana Dental , Diseño Asistido por Computadora , Coronas , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Ensayo de Materiales , Propiedades de Superficie
15.
J Esthet Restor Dent ; 31(2): 153-159, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30394660

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the color parameters and optical properties of resin cements (RCs) formulated with thio-urethanes (TUs). MATERIALS AND METHODS: Six TUs were synthesized by combining thiols (pentaerythritol tetra-3-mercaptopropionate [PETMP] or trimethylol-tris-3-mercaptopropionate [TMP]) with di-functional isocyanates (1,6-Hexanediol-diissocyante [HDDI] [aliphatic-AL] or 1,3-bis(1-isocyanato-1-methylethyl) benzene [BDI] [aromatic-AR] or Dicyclohexylmethane 4,4'-Diisocyanate [HMDI] [cyclic-CC]). TUs (20 wt%) were added to a BisGMA/UDMA/TEGDMA matrix. Filler was introduced at 60 wt%. Fluorescence was evaluated through an UV-light emitting equipment. Coordinates L*, a*, and b* were obtained in the black and white reflectance to evaluate the contrast ratio (CR) and translucency parameter (TP00 ). The coordinates obtained from transmittance were used to evaluate lightness (L*), chroma (C*), color difference (ΔE00 ) after 6 month, and whiteness index for Dentistry (WID ). RESULTS: RCs formulated with TUs presented significantly higher CR, and fluorescence (with T_AR). Significantly lower C*, L*, and TP00 (except for P_AR and T_AL) were also observed in RCs containing TUs. ΔE00 were not significant among the materials. WID was not influenced. CONCLUSION: RCs composed by TU oligomers present higher CR and lower translucency. The material also present higher fluorescence depending on the oligomer used. CLINICAL SIGNIFICANCE: The use of thio-urethanes to formulate resin cements can ensure a luting material with improved potential to mask colored substrates due to the higher contrast ratio and lower translucency obtained. A final higher fluorescence of restoration is also expected with the use of specific oligomer.


Asunto(s)
Cementos de Resina , Uretano , Color , Colorimetría , Resinas Compuestas , Módulo de Elasticidad , Ensayo de Materiales , Estrés Mecánico
16.
J Prosthet Dent ; 121(1): 22-25, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29961631

RESUMEN

Discolored substrates constitute a challenge to the esthetics of the definitive restoration. Because of technique sensitivity, the generally prolonged treatment time is a drawback to both the patient and the dentist. The technique described presents the replacement of ceramic maxillary incisors crowns over discolored substrates in a single visit by using a milling machine. Translucent blocks of a lithium silicate ceramic reinforced with zirconium dioxide particles were used. Intraoral scans of the trial restorations and of the tooth preparations were performed. The crown parameters were defined in the software. Ceramic blocks were milled in the presintered phase and characterized. The crowns were cemented at the end of the appointment with excellent esthetics.


Asunto(s)
Cerámica/química , Color , Diseño Asistido por Computadora , Coronas , Incisivo , Compuestos de Litio/química , Maxilar , Silicatos/química , Pilares Dentales , Adaptación Marginal Dental , Materiales Dentales/química , Porcelana Dental/química , Diseño de Prótesis Dental , Estética Dental , Recesión Gingival , Humanos , Polivinilos/química , Coloración de Prótesis , Siloxanos/química , Preparación del Diente/métodos , Circonio/química
17.
J Oral Implantol ; 45(5): 343-350, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31429636

RESUMEN

Obtaining parallelism during implant placement is often difficult, leading to inclination of implants. The present study evaluated the stress distribution in 3-unit fixed partial dentures supported by 2 implants with different inclinations and prosthetic abutments. Universal castable long abutments (UCLAs) or tapered abutments were used considering 17° of implant angulation in different directions (mesial, distal, buccal, or lingual). To do so, 3-dimensional finite element models were built and exported to specific analysis software. Forces were applied to the functional cusps. Data were obtained with regard to the maximum principal and von Mises stresses (in MPa). No relevant differences were observed in the stress values in the cortical and cancellous bone nor in the prosthesis with UCLA or tapered abutments. However, a relevant stress reduction in the prosthetic screws of the tilted implant was observed when using UCLA abutments. According to the obtained results, it is possible to suggest that both UCLA or tapered abutments can be used for 3-unit fixed partial dentures when 1 of the implants is tilted. UCLA abutment might lead to less biomechanical problems related to screw loosening or fracture.


Asunto(s)
Implantes Dentales , Prótesis Dental de Soporte Implantado , Fenómenos Biomecánicos , Pilares Dentales , Análisis del Estrés Dental , Dentadura Parcial Fija , Análisis de Elementos Finitos , Estrés Mecánico
18.
J Prosthodont ; 28(1): e350-e356, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29756670

RESUMEN

PURPOSE: To evaluate the influence of different post systems on the biomechanical behavior of teeth with a severe loss of remaining coronal structure. MATERIALS AND METHODS: Fifty standardized bovine teeth (n = 10 per group) were restored with: cast post-and-core (CPC), prefabricated metallic post (PFM), parallel glass-fiber post (P-FP), conical glass-fiber post (C-FP), or composite core (no post, CC). The survival rate during thermomechanical challenging (TC), the fracture strength (FS), and failure patterns (FP) were evaluated. Finite element models evaluated the stress distribution after the application of 100 N. RESULTS: All specimens survived TC. Similar FS was observed among post-containing groups. Groups P-FP and CC presented 100% repairable fractures. The von Mises analysis showed the maximum stresses into the root canal in groups restored with metallic posts. Glass-fiber posts and CC presented the maximum stresses at the load contact point. Glass-fiber groups showed lower stresses in the analysis of maximal contact pressure; CPC led to the highest values of contact pressure. The modified von Mises (mvM) stress in dentin did not show differences among groups. Moreover, mvM values did not reach the dentin fracture limit for any group. CONCLUSIONS: The type of intracanal post had a relevant influence on the biomechanical behavior of teeth with little remaining coronal structure.


Asunto(s)
Técnica de Perno Muñón , Diente no Vital/cirugía , Animales , Bovinos , Materiales Dentales/efectos adversos , Materiales Dentales/uso terapéutico , Diseño de Prótesis Dental , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Vidrio , Técnica de Perno Muñón/efectos adversos , Técnica de Perno Muñón/instrumentación
19.
Implant Dent ; 27(4): 445-451, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29944484

RESUMEN

PURPOSE: To evaluate by 3-dimensional (3-D) finite element analysis the stress generated on overdenture-retaining bar system with different cross sections (round, ovoid, or Hader) and misfit levels (50, 100, and 200 µm) manufactured with different metallic alloys (Au type IV, Ag-Pd, Ti cp, and Co-Cr). MATERIALS AND METHODS: Three-dimensional finite element models were modeled using specific 3-D software (SolidWorks) and imported into mechanical simulation software (ANSYS). A displacement simulating the settlement of the screw was performed until the infrastructure was settled properly on the prosthetic platform. RESULTS: Higher misfit levels caused higher stress on the overdenture-retaining bar system components, where (1) Hader bar presented the highest values (bar = 730.71; screw = 59.66, and periimplant bone tissue = 42.96, in megapascal) and (2) round bars made with type IV Au alloy presented lower stress values on the bar framework (193.99 MPa) and screw (10.27 MPa). CONCLUSIONS: Higher vertical misfit increased the stress values on the overdenture-retaining bar system; complex cross-sectional designs increased stress values on the bar framework, prosthetic screw, and periimplant bone tissue; stiffer alloys caused higher stress values on all the studied conditions.


Asunto(s)
Prótesis Dental de Soporte Implantado , Diseño de Dentadura , Retención de Dentadura/instrumentación , Prótesis de Recubrimiento , Fenómenos Biomecánicos , Simulación por Computador , Aleaciones Dentales/química , Análisis del Estrés Dental , Análisis de Elementos Finitos , Humanos , Imagenología Tridimensional , Técnicas In Vitro , Ensayo de Materiales , Programas Informáticos , Propiedades de Superficie
20.
J Esthet Restor Dent ; 30(5): 390-396, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29920918

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the color stability of two resin-based composites photo-activated by two light curing units (LCU) with different irradiances. MATERIALS AND METHODS: Hundred disc-shaped specimens (2-mm thick) of a nanofilled (FZ- FiltekTM Z350 XT, 3M ESPE) and a microhybrid (ED-Empress® Direct, Ivoclar Vivadent) composites were photo-activated with two LCU: Valo® Cordless, Ultradent (VA-1800 mW/cm2 ) or Radii-cal, SDI (RA-900 mW/cm2 ). Samples (n = 5) were immersed during 12 days in distilled water (WT), orange juice (OJ), red wine (RW), coffee (CF), or Brazilian tea (BT). CIELAB coordinates were obtained using a spectrophotometer (Easyshade 4.0, Vita Zahnfabrik) before (T0 ) and after (T1 ) immersion. CIEDE2000 color difference (ΔE00 ) and whiteness index for dentistry (WID ) were calculated. Data was analyzed by two-way ANOVA and Tukey's test (α = 0.05%). RESULTS: FZ light-activated by VA showed higher L* and WID values (T0 ) and lower ΔE00 values after immersion in WT, OJ, and RW. However, there was no effect of both factors on ΔE00 when samples were immersed in BT and CF. ED light-activated by RA showed significant higher C* values (p ≤ .05). CONCLUSIONS: The nanofilled composite photo-activated with higher irradiance showed greater L* and WID values and better color stability. However, all samples immersed in colored beverages showed ΔE00 values above the acceptability threshold. CLINICAL SIGNIFICANCE: Initial color of resin-based composites can change after immersion in staining beverages. However, the best color stability was obtained by the nanocomposite photo-activated by a light-curing unit of higher irradiance.


Asunto(s)
Resinas Compuestas , Materiales Dentales , Bebidas , Café , Color , Ensayo de Materiales , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA