Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur J Dent ; 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38776981

RESUMEN

OBJECTIVE: The focus of this triple-blind randomized study was to evaluate the biocompatibility of a new root canal filling sealer (RCFS) based on tristrontium aluminate and dodecacalcium hepta-aluminate in living tissue. MATERIAL AND METHODS: Forty-five Wistar rats (Rattus norvegicus) were divided into three groups: control (polyethylene), sealer (Bio-C Sealer, Londrina, PR, Brazil), and experimental (tristrontium aluminate and dodecacalcium hepta-aluminate). The tissues were analyzed under an optical microscope to assess different cellular events at different time intervals (7, 15, and 30 days). STATISTICAL ANALYSIS: Data were analyzed using the Kruskal-Wallis and Dunn (p < 0.05) tests. RESULTS: In the initial period, a moderate inflammatory infiltrate was observed, similar between the endodontic cements groups (p = 0.725). The intensity of the infiltrate decreased with time, with no significant difference among the groups (p > 0.05). The number of young fibroblasts was elevated in all groups evaluated at 7 days. The experimental group showed the highest number of cells at all time intervals, but the difference with the sealer group at 7 (p = 0.001) and 15 days (p = 0.002) and the control group at 30 days was not significant (p = 0.001). Regarding tissue repair events, the amount of collagen fibers increased over the experimental intervals, with no significant difference between the sealer and control groups (p > 0.05). CONCLUSION: The experimental RCFS based on calcium and strontium aluminates proved to be biocompatible for use in close contact with periapical tissue, inducing a low inflammatory reaction and favoring rapid tissue repair.

2.
Polymers (Basel) ; 14(18)2022 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-36145867

RESUMEN

To modify its characteristics, expand its applicability, and, in some cases, its processability, new blends using ultra-high-molecular-weight polyethylene (UHMWPE) have been developed. In this study, three different formulations of linear low-density polyethylene (LLDPE) and UHMWPE blends were prepared with 15, 30, and 45% (% w/w) UHMWPE in the LLDPE matrix. All mixtures were prepared by hot pressing and were immersed in water for one hour afterwards at a controlled temperature of 90 °C to relieve the internal stresses that developed during the forming process. The thermal characterization showed that the blends showed endothermic peaks with different melting temperatures, which may be the result of co-crystallization without mixing between the polymers during the forming process. The mechanical characteristics presented are typical of a ductile material, but with the increase in the percentage of UHMWPE, there was a decrease in the ductility of the blends, as the elongation at rupture of the blends was higher than that of the pure components. The morphologies observed by SEM indicate that there were two phases in the blends. This is the result of the system's immiscibility due to the mode of preparation of the blends, wherein the two polymers may not have mixed intimately, confirming the results found with the thermal analyses.

3.
Healthcare (Basel) ; 9(6)2021 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-34207413

RESUMEN

The SARS-CoV-2 pandemic in Brazil has grown rapidly since the first case was reported on 26 February 2020. As the pandemic has spread, the low availability of medical equipment has increased, especially mechanical ventilators. The Brazilian Unified Health System (SUS) claimed to have only 40,508 mechanical ventilators, which would be insufficient to support the Brazilian population at the pandemic peak. This lack of ventilators, especially in public hospitals, required quick, assertive, and effective actions to minimize the health crisis. This work provides an overview of the rapid deployment of a network for maintaining disused mechanical ventilators in public and private healthcare units in some regions of Brazil during the SARS-CoV-2 pandemic. Data referring to the processes of maintaining equipment, acquiring parts, and conducting national and international training were collected and analyzed. In total, 4047 ventilators were received by the maintenance sites, and 2516 ventilators were successfully repaired and returned to the healthcare units, which represents a success rate of 62.17%. The results show that the maintenance initiative directly impacted the availability and reliability of the equipment, allowing access to ventilators in the public and private health system and increasing the capacity of beds during the pandemic.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA