Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 208
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Magn Reson Imaging ; 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38426608

RESUMEN

BACKGROUND: In patients with bicuspid aortic valve (BAV), 4D flow MRI can quantify regions exposed to abnormal aortic hemodynamics, including high wall shear stress (WSS), a known stimulus for arterial wall dysfunction. However, the long-term multiscan reproducibility of 4D flow MRI-derived hemodynamic parameters is unknown. PURPOSE: To investigate the long-term stability of 4D flow MRI-derived peak velocity, WSS, and WSS-derived heatmaps in patients with BAV undergoing multiyear surveillance imaging. STUDY TYPE: Retrospective. POPULATION: 20 BAV patients (mean age 48.4 ± 13.9 years; 14 males) with five 4D flow MRI scans, with intervals of at least 6 months between scans, and 125 controls (mean age: 50.7 ± 15.8 years; 67 males). FIELD STRENGTH/SEQUENCE: 1.5 and 3.0T, prospectively ECG and respiratory navigator-gated aortic 4D flow MRI. ASSESSMENT: Automated AI-based 4D flow analysis pipelines were used for data preprocessing, aorta 3D segmentation, and quantification of ascending aorta (AAo) peak velocity, peak systolic WSS, and heatmap-derived relative area of elevated WSS compared to WSS ranges in age and sex-matched normative control populations. Growth rate was derived from the maximum AAo diameters measured on the first and fifth MRI scans. STATISTICAL TESTS: One-way repeated measures analysis of variance. P < 0.05 indicated significance. RESULTS: One hundred 4D flow MRI exams (five per patient) were analyzed. The mean total follow-up duration was 5.5 ± 1.1 years, and the average growth rate was 0.3 ± 0.2 mm/year. Peak velocity, peak systolic WSS, and relative area of elevated WSS did not change significantly over the follow-up period (P = 0.64, P = 0.69, and P = 0.35, respectively). The patterns and areas of elevated WSS demonstrated good reproducibility on semiquantitative assessment. CONCLUSION: 4D flow MRI-derived peak velocity, WSS, and WSS-derived heatmaps showed good multiyear and multiscan stability in BAV patients with low aortic growth rates. These findings underscore the reliability of these metrics in monitoring BAV patients for potential risk of dilation. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 1.

2.
Diabetes Obes Metab ; 26(7): 2662-2672, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38584515

RESUMEN

AIM: Type 1 diabetes (T1D) increases the risk of morbidity and mortality from cardiovascular disease, and insufficient sleep is prevalent. Emerging evidence suggests a link between sleep and cardiometabolic health, but this has not been examined across the lifespan in individuals with T1D. We aimed to examine associations between sleep and cardiometabolic health in adolescents and adults with T1D in a secondary analysis of data from a 4-week double-blind, random-order, placebo-controlled crossover trial of bromocriptine quick release (BCQR) therapy with a 4-week washout in between conditions. MATERIALS AND METHODS: Forty-two adults (19-60 years) and 42 adolescents (12-18 years) with T1D >9 months completed 1 week of home monitoring with wrist-worn actigraphy to estimate sleep duration and continuous glucose monitoring, anthropometrics, arterial stiffness, magnetic resonance imaging (adolescents only), and fasting laboratory testing at each treatment phase. RESULTS: Sixty-two per cent of adolescents and 74% of adults obtained <7 h of sleep per night at baseline. After adjustment for age, sex and diabetes duration, baseline sleep <7 h per night was associated with a higher body mass index, a higher waist circumference, a higher systolic blood pressure, worse arterial stiffness and a lower estimated insulin sensitivity (all p < .05). When examined by age group, associations between sleep duration and cardiometabolic health outcomes remained significant, predominantly for adolescents. In adolescents only, wake time was significantly later (p = .027) and time in bed was significantly longer with BCQR versus placebo (p = .049). CONCLUSIONS: Objectively measured sleep <7 h per night was prevalent in adolescents and adults with T1D and associated with poorer cardiometabolic health markers. Small changes in sleep were seen following BCQR treatment in adolescents only. Sleep may be an important and novel target for improving cardiometabolic health in individuals with T1D.


Asunto(s)
Estudios Cruzados , Diabetes Mellitus Tipo 1 , Sueño , Humanos , Adolescente , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/fisiopatología , Diabetes Mellitus Tipo 1/sangre , Masculino , Femenino , Adulto , Adulto Joven , Sueño/fisiología , Método Doble Ciego , Persona de Mediana Edad , Enfermedades Cardiovasculares/etiología , Enfermedades Cardiovasculares/epidemiología , Rigidez Vascular/fisiología , Niño , Actigrafía , Duración del Sueño
3.
Chemistry ; 29(22): e202203981, 2023 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-36695295

RESUMEN

A series of zigzag-edged polycyclic aromatic hydrocarbons (PAHs) (Z1-Z3) were synthesized from 2,12-dibromo-7,14-diphenyl-benzo[m]tetraphene (9) as a versatile building block. Their structures were unambiguously confirmed by laser desorption/ionization time-of-flight mass spectrometry, 1 H NMR, Raman, and Fourier-transformed infrared (FTIR) spectroscopies as well as scanning tunneling microscopy. The fingerprint vibrational modes were elucidated with theoretical support. The edge- and size-dependent optical properties were characterized by UV-Vis absorption and fluorescence spectroscopy and DFT calculations. Moreover, ultrafast transient absorption spectroscopy revealed distinct modulation of the photophysical properties upon π-extension from Z1 to Z2, the latter having a gulf edge.

4.
J Magn Reson Imaging ; 2023 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-37855630

RESUMEN

BACKGROUND: Recent advances in hardware and software permit the use of cardiac MRI of late gestation fetuses, however there is a paucity of MRI-based reference values. PURPOSE: To provide initial data on fetal cardiac MRI-derived cardiac dimensions, volumes, ventricular function, and left ventricular longitudinal strain in healthy developing fetuses >30 weeks gestational age. STUDY TYPE: Prospective. POPULATION: Twenty-five third trimester (34 ± 1 weeks, range of 32-37 weeks gestation) women with healthy developing fetuses. FIELD STRENGTH/SEQUENCE: Studies were performed at 1.5 T and 3 T. Cardiac synchronization was achieved with a Doppler ultrasound device. The protocol included T2 single shot turbo spin echo stacks for fetal weight and ultrasound probe positioning, and multiplanar multi-slice cine balanced steady state free precession gradient echo sequences. ASSESSMENT: Primary analyses were performed by a single observer. Weight indexed right ventricular (RV) and left ventricular (LV) volumes and function were calculated from short axis (SAX) stacks. Cardiac dimensions were calculated from the four-chamber and SAX stacks. Single plane LV longitudinal strain was calculated from the four-chamber stack. Interobserver variability was assessed in 10 participants. Cardiac MRI values were compared against available published normative fetal echocardiogram data using z-scores. STATISTICAL TESTS: Mean and SDs were calculated for baseline maternal/fetal demographics, cardiac dimensions, volumes, ventricular function, and left ventricular longitudinal strain. Bland-Altman and intraclass correlation coefficient analysis was performed to test interobserver variability. RESULTS: The mean gestational age was 34 ± 1.4 weeks. The mean RV and LV end diastolic volumes were 3.1 ± 0.6 mL/kg and 2.4 ± 0.5 mL/kg respectively. The mean RV cardiac output was 198 ± 49 mL/min/kg while the mean LV cardiac output was 173 ± 43 mL/min/kg. DATA CONCLUSION: This paper reports initial reference values obtained by cardiac MRI in healthy developing third trimester fetuses. MRI generally resulted in slightly larger indexed values (by z-score) compared to reports in literature using fetal echocardiography. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.

5.
J Magn Reson Imaging ; 57(1): 126-136, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35633284

RESUMEN

BACKGROUND: Aortopathy is common with bicuspid aortic valve (BAV), and underlying intrinsic tissue abnormalities are believed causative. Valve-mediated hemodynamics are altered in BAV and may contribute to aortopathy and its progression. The contribution of intrinsic tissue defects versus altered hemodynamics to aortopathy progression is not known. PURPOSE: To investigate relative contributions of tissue-innate versus hemodynamics in progression of BAV aortopathy. STUDY TYPE: Retrospective. SUBJECTS: Four hundred seventy-three patients with aortic dilatation (diameter ≥40 mm; comprised of 281 BAV with varied AS severity, 192 tricuspid aortic valve [TAV] without AS) and 124 healthy controls. Subjects were 19-91 years (141/24% female). FIELD STRENGTH/SEQUENCE: 1.5T, 3T; time-resolved gradient-echo 3D phase-contrast (4D flow) MRI. ASSESSMENT: A surrogate measure for global aortic wall stiffness, pulse wave velocity (PWV), was quantified from MRI by standardized, automated technique based on through-plane flow cross-correlation maximization. Comparisons were made between BAV patients with aortic dilatation and varying aortic valve stenosis (AS) severity and healthy subjects and aortopathy patients with normal TAV. STATISTICAL TESTS: Multivariable regression, analysis of covariance (ANCOVA), Tukey's, student's (t), Mann-Whitney (U) tests, were used with significance levels P < 0.05 or P < 0.01 for post-hoc Bonferroni-corrected t/U tests. Bland-Altman and ICC calculations were performed. RESULTS: Multivariable regression showed age with the most significant association for increased PWV in all groups (increase 0.073-0.156 m/sec/year, R2  = 0.30-48). No significant differences in aortic PWV were observed between groups without AS (P = 0.20-0.99), nor were associations between PWV and regurgitation or Sievers type observed (P = 0.60, 0.31 respectively). In contrast, BAV AS patients demonstrated elevated PWV and a significant relationship for AS severity with increased PWV (covariate: age, R2  = 0.48). BAV and TAV patients showed no association between aortic diameter and PWV (P = 0.73). DATA CONCLUSION: No significant PWV differences were observed between BAV patients with normal valve function and control groups. However, AS severity and age in BAV patients were directly associated with PWV increases. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 3.


Asunto(s)
Enfermedades de la Aorta , Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Humanos , Femenino , Masculino , Válvula Aórtica/diagnóstico por imagen , Análisis de la Onda del Pulso , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/complicaciones , Enfermedad de la Válvula Aórtica Bicúspide/complicaciones , Enfermedades de la Aorta/diagnóstico por imagen , Hemodinámica
6.
Eur Radiol ; 33(1): 302-311, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35852579

RESUMEN

OBJECTIVES: Flow through the proximal pulmonary arteries (PAs) of patients with repaired Tetralogy of Fallot (TOF) is known to be highly disordered and associated with significant regurgitation. The purpose of this study was to evaluate 4D-Flow MRI-derived viscous energy loss [Formula: see text])-as a result of non-efficient flow propagation, and relate this parameter to standard right ventricular (RV) size and function markers in patients with repaired TOF. METHODS: Thirty-five patients with TOF and 14 controls underwent comprehensive 4D-Flow MRI evaluation for qualitative flow analysis and to calculate [Formula: see text] in the main and right pulmonary arteries. Sampled [Formula: see text] indices were correlated with the MRI-derived RV size and functional indices. RESULTS: All patients with TOF exhibited abnormal, supra-physiologic helical/vortical formations in the PAs. Patients with TOF had significantly increased peak systolic [Formula: see text] (8.0 vs 0.5 mW, p < 0.001), time-averaged [Formula: see text] (2.5 vs. 0.2 mW, p < 0.001), and peak systolic [Formula: see text] indexed to stroke volume (0.082 vs. 0.012 mW/mL, p < 0.001). [Formula: see text] indexed to stroke volume correlated with the RV end-diastolic volume (R = 0.68, p < 0.001), end-systolic volume (R = 0.62, p < 0.001), ejection fraction (R = -0.45, p = 0.002), and cardiac index (R = 0.45, p = 0.002). The mean estimated energy loss due to [Formula: see text] with regard to input RV mechanical power was 4.7%. CONCLUSION: This study demonstrates that patients with repaired TOF have highly abnormal flow conduction through the PAs which result into extensive viscous energy loss. This significant flow-mediated energy loss is associated with the RV volume and function, and might represent considerable loss of mechanical power generated by each cardiac cycle. Future studies are required to assess whether the abnormal flow conduction adds to the RV afterload and remodeling. KEY POINTS: • Abnormal flow patterns through proximal pulmonary arteries in patients with TOF are associated with excessive viscous energy loss. • Inefficient flow conduction is associated with the RV dilation and reduced function and might contribute to the RV adaptive remodeling.


Asunto(s)
Insuficiencia de la Válvula Pulmonar , Tetralogía de Fallot , Disfunción Ventricular Derecha , Humanos , Tetralogía de Fallot/cirugía , Arteria Pulmonar/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Volumen Sistólico , Sístole , Remodelación Ventricular , Función Ventricular Derecha/fisiología , Disfunción Ventricular Derecha/diagnóstico por imagen
7.
J Cardiovasc Magn Reson ; 25(1): 40, 2023 07 20.
Artículo en Inglés | MEDLINE | ID: mdl-37474977

RESUMEN

Hemodynamic assessment is an integral part of the diagnosis and management of cardiovascular disease. Four-dimensional cardiovascular magnetic resonance flow imaging (4D Flow CMR) allows comprehensive and accurate assessment of flow in a single acquisition. This consensus paper is an update from the 2015 '4D Flow CMR Consensus Statement'. We elaborate on 4D Flow CMR sequence options and imaging considerations. The document aims to assist centers starting out with 4D Flow CMR of the heart and great vessels with advice on acquisition parameters, post-processing workflows and integration into clinical practice. Furthermore, we define minimum quality assurance and validation standards for clinical centers. We also address the challenges faced in quality assurance and validation in the research setting. We also include a checklist for recommended publication standards, specifically for 4D Flow CMR. Finally, we discuss the current limitations and the future of 4D Flow CMR. This updated consensus paper will further facilitate widespread adoption of 4D Flow CMR in the clinical workflow across the globe and aid consistently high-quality publication standards.


Asunto(s)
Sistema Cardiovascular , Humanos , Velocidad del Flujo Sanguíneo , Valor Predictivo de las Pruebas , Corazón , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética
8.
Pediatr Nephrol ; 38(8): 2877-2881, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36459246

RESUMEN

BACKGROUND: Glomerular filtration rate (GFR) is a key measure of kidney function but often inaccurately ascertained by serum creatinine and cystatin C in pediatrics. In this pilot trial, we evaluated the relationship between GFR calculated by using phase-contrast MRI (PC-MRI) biomarkers and GFR by 125I-iothalamate clearance in youth undergoing bone marrow transplantation (BMT). METHODS: A total of twenty-one pediatric BMT candidates (8-21 years of age) were recruited for a research kidney PC-MRI. After completion of 125I-iothalamate clearance, same-day PC-MRI measurements were completed of the kidney circulation without a gadolinium-based contrast agent. MRI included a non-contrast balanced-SSFP-triggered angiography to position ECG-gated breath-held 2D PC-MRI flow measurements (1.2 × 1.2 × 6 mm3). A multivariate model of MRI biomarkers estimating GFR (GFR-MRI) was selected using the elastic net approach. RESULTS: The GFR-MRI variables selected by elastic net included average heart rate during imaging (bpm), peak aorta flow below the kidney artery take-offs (ml/s), average kidney artery blood flow, average peak kidney vein blood flow, and average kidney vein blood flow (ml/s). The GFR-MRI model demonstrated strong agreement with GFR by 125I-iothalamate (R2 = 0.65), which was stronger than what was observed with eGFR by the full age spectrum and Chronic Kidney Disease in Children under 25 (CKiD U25) approaches. CONCLUSION: In this pilot study, noninvasive GFR-MRI showed strong agreement with gold standard GFR in youth scheduled for BMT. Further work is needed to evaluate whether non-contrast GFR-MRI holds promise to become a superior alternative to eGFR and GFR by clearance techniques. A higher resolution version of the Graphical abstract is available as Supplementary information.


Asunto(s)
Ácido Yotalámico , Riñón , Adolescente , Humanos , Niño , Tasa de Filtración Glomerular/fisiología , Proyectos Piloto , Biomarcadores , Imagen por Resonancia Magnética , Creatinina
9.
Pediatr Radiol ; 53(5): 885-891, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36697721

RESUMEN

BACKGROUND: Modern CT scanners with lower radiation doses have resulted in large numbers of cardiac CTs being performed in children. As seen in adults, pediatric cardiac CT has the potential to demonstrate extracardiac variants and pathology that can occur in conjunction with congenital heart disease (CHD). Prior publications demonstrated a high incidence of extracardiac findings in various locations but the prevalence of urgent unexpected extracardiac findings in children is unknown. OBJECTIVE: The purpose of this study was to describe the incidence, distribution and clinical significance of the extracardiac findings on pediatric cardiac CT at a tertiary referral center. MATERIALS AND METHODS: We reviewed all reports (n = 648) for 554 children through young adults who received a cardiac CT study between Jan. 2, 2018, and March 10, 2020, at our tertiary referral pediatric hospital. We interrogated CT reports for extracardiac findings and categorized them by system (airway, pulmonary, abdomen, malpositioned lines and musculoskeletal). We then subclassified each of these findings by level of clinical importance based upon the need for intervention or treatment into low, medium or high importance. High-importance findings were confirmed with a focused chart review. If a patient had more than one CT with a persistent extracardiac finding, the finding was only counted once. RESULTS: We identified 562 individual extracardiac findings, with one or more extracardiac findings present in 91% of the study population. Extracardiac findings with high clinical importance, requiring urgent attention or intervention, were present in 10% (57/554) of cases. The most common location of extracardiac findings was pulmonary (50%; 280/562), followed by airway (22%; 125/562) and abdomen (9%; 52/562). CONCLUSION: Unexpected highly important extracardiac findings were found in 10% of patients. Therefore, extracardiac structures should be scrutinized for the timely identification of potentially highly important findings.


Asunto(s)
Cardiopatías Congénitas , Tomografía Computarizada por Rayos X , Recién Nacido , Humanos , Niño , Adulto Joven , Tomografía Computarizada por Rayos X/métodos , Cardiopatías Congénitas/diagnóstico por imagen , Corazón , Prevalencia , Estudios Retrospectivos
10.
Magn Reson Med ; 88(1): 449-463, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35381116

RESUMEN

PURPOSE: To develop a convolutional neural network (CNN) for the robust and fast correction of velocity aliasing in 4D-flow MRI. METHODS: This study included 667 adult subjects with aortic 4D-flow MRI data with existing velocity aliasing (n = 362) and no velocity aliasing (n = 305). Additionally, 10 controls received back-to-back 4D-flow scans with systemically varied velocity-encoding sensitivity (vencs) at 60, 100, and 175 cm/s. The no-aliasing data sets were used to simulate velocity aliasing by reducing the venc to 40%-70% of the original, alongside a ground truth locating all aliased voxels (153 training, 152 testing). The 152 simulated and 362 existing aliasing data sets were used for testing and compared with a conventional velocity antialiasing algorithm. Dice scores were calculated to quantify CNN performance. For controls, the venc 175-cm/s scans were used as the ground truth and compared with the CNN-corrected venc 60 and 100 cm/s data sets RESULTS: The CNN required 176 ± 30 s to perform compared with 162 ± 14 s for the conventional algorithm. The CNN showed excellent performance for the simulated data compared with the conventional algorithm (median range of Dice scores CNN: [0.89-0.99], conventional algorithm: [0.84-0.94], p < 0.001, across all simulated vencs) and detected more aliased voxels in existing velocity aliasing data sets (median detected CNN: 159 voxels [31-605], conventional algorithm: 65 [7-417], p < 0.001). For controls, the CNN showed Dice scores of 0.98 [0.95-0.99] and 0.96 [0.87-0.99] for venc = 60 cm/s and 100 cm/s, respectively, while flow comparisons showed moderate-excellent agreement. CONCLUSION: Deep learning enabled fast and robust velocity anti-aliasing in 4D-flow MRI.


Asunto(s)
Aprendizaje Profundo , Imagenología Tridimensional , Adulto , Velocidad del Flujo Sanguíneo , Humanos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Reproducibilidad de los Resultados
11.
J Magn Reson Imaging ; 56(2): 464-473, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35001455

RESUMEN

BACKGROUND: Evaluation of aortic stiffness by pulse wave velocity (PWV) across the adult lifespan is needed to better understand normal aging in women and men. PURPOSE: To characterize PWV in the thoracic aorta using 4D flow MRI in an age- and sex-stratified cohort of healthy adults. STUDY TYPE: Retrospective. POPULATION: Ninety nine healthy participants (age: 46 ± 15 [19-79] years, 50% female), divided into young adults (<45 years) (N = 48), midlife (45-65 years) (N = 37), and later life (>65 years) (N = 14) groups. FIELD STRENGTH/SEQUENCE: 1.5 T or 3 T, 2D cine bSSFP, 4D flow MRI. ASSESSMENT: Cardiac functional parameters of end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and myocardial mass were assessed by 2D cine bSSFP. PWV and aortic blood flow velocity were assessed by 4D flow MRI. Reproducibility of PWV was evaluated in a subset of nine participants. STATISTICAL TESTS: Analysis of variance, Pearson's correlation coefficient (r), linear regression, intraclass correlation coefficient (ICC). A P value < 0.05 was considered statistically significant. RESULTS: PWV increased significantly with age (young adults: 5.4 ± 0.9 m/sec, midlife: 7.2 ± 1.1 m/sec, and later life: 9.4 ± 1.8 m/sec) (r = 0.79, slope = 0.09 m/sec/year). PWV did not differ in women and men in entire sample (P = 0.40) or within age groups (young adults: P = 0.83, midlife: P = 0.17, and later life: P = 0.96). PWV was significantly correlated with EDV (r = -0.29), ESV (r = -0.23), SV (r = -0.28), myocardial mass (r = 0.21), and mean aortic blood flow velocity (r = -0.62). In the test-retest subgroup (N = 9), PWV was 6.7 ± 1.5 [4.4-9.3] m/sec and ICC = 0.75. DATA CONCLUSION: 4D flow MRI quantified higher aortic PWV with age, by approximately 1 m/sec per decade, and significant differences between young adults, midlife and later life. Reproducibility analysis showed good test-retest agreement. Increased PWV was associated with decline in cardiac function and reduced aortic blood flow velocity. This study demonstrates the utility of 4D flow MRI-derived aortic PWV for studying aging. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Análisis de la Onda del Pulso , Rigidez Vascular , Adulto , Velocidad del Flujo Sanguíneo , Femenino , Humanos , Longevidad , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Adulto Joven
12.
J Magn Reson Imaging ; 55(6): 1666-1680, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34792835

RESUMEN

BACKGROUND: Automated segmentation using convolutional neural networks (CNNs) have been developed using four-dimensional (4D) flow magnetic resonance imaging (MRI). To broaden usability for congenital heart disease (CHD), training with multi-institution data is necessary. However, the performance impact of heterogeneous multi-site and multi-vendor data on CNNs is unclear. PURPOSE: To investigate multi-site CNN segmentation of 4D flow MRI for pediatric blood flow measurement. STUDY TYPE: Retrospective. POPULATION: A total of 174 subjects across two sites (female: 46%; N = 38 healthy controls, N = 136 CHD patients). Participants from site 1 (N = 100), site 2 (N = 74), and both sites (N = 174) were divided into subgroups to conduct 10-fold cross validation (10% for testing, 90% for training). FIELD STRENGTH/SEQUENCE: 3 T/1.5 T; retrospectively gated gradient recalled echo-based 4D flow MRI. ASSESSMENT: Accuracy of the 3D CNN segmentations trained on data from single site (single-site CNNs) and data across both sites (multi-site CNN) were evaluated by geometrical similarity (Dice score, human segmentation as ground truth) and net flow quantification at the ascending aorta (Qs), main pulmonary artery (Qp), and their balance (Qp/Qs), between human observers, single-site and multi-site CNNs. STATISTICAL TESTS: Kruskal-Wallis test, Wilcoxon rank-sum test, and Bland-Altman analysis. A P-value <0.05 was considered statistically significant. RESULTS: No difference existed between single-site and multi-site CNNs for geometrical similarity in the aorta by Dice score (site 1: 0.916 vs. 0.915, P = 0.55; site 2: 0.906 vs. 0.904, P = 0.69) and for the pulmonary arteries (site 1: 0.894 vs. 0.895, P = 0.64; site 2: 0.870 vs. 0.869, P = 0.96). Qs site-1 medians were 51.0-51.3 mL/cycle (P = 0.81) and site-2 medians were 66.7-69.4 mL/cycle (P = 0.84). Qp site-1 medians were 46.8-48.0 mL/cycle (P = 0.97) and site-2 medians were 76.0-77.4 mL/cycle (P = 0.98). Qp/Qs site-1 medians were 0.87-0.88 (P = 0.97) and site-2 medians were 1.01-1.03 (P = 0.43). Bland-Altman analysis for flow quantification found equivalent performance. DATA CONCLUSION: Multi-site CNN-based segmentation and blood flow measurement are feasible for pediatric 4D flow MRI and maintain performance of single-site CNNs. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Imagen por Resonancia Magnética , Arteria Pulmonar , Aorta/diagnóstico por imagen , Niño , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Redes Neurales de la Computación , Arteria Pulmonar/diagnóstico por imagen , Estudios Retrospectivos
13.
Clin Orthop Relat Res ; 480(11): 2232-2250, 2022 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-36001022

RESUMEN

BACKGROUND: A nanostructured titanium surface that promotes antimicrobial activity and osseointegration would provide the opportunity to create medical implants that can prevent orthopaedic infection and improve bone integration. Although nanostructured surfaces can exhibit antimicrobial activity, it is not known whether these surfaces are safe and conducive to osseointegration. QUESTIONS/PURPOSES: Using a sheep animal model, we sought to determine whether the bony integration of medical-grade, titanium, porous-coated implants with a unique nanostructured surface modification (alkaline heat treatment [AHT]) previously shown to kill bacteria was better than that for a clinically accepted control surface of porous-coated titanium covered with hydroxyapatite (PCHA) after 12 weeks in vivo. The null hypothesis was that there would be no difference between implants with respect to the primary outcomes: interfacial shear strength and percent intersection surface (the percentage of implant surface with bone contact, as defined by a micro-CT protocol), and the secondary outcomes: stiffness, peak load, energy to failure, and micro-CT (bone volume/total volume [BV/TV], trabecular thickness [Tb.Th], and trabecular number [Tb.N]) and histomorphometric (bone-implant contact [BIC]) parameters. METHODS: Implants of each material (alkaline heat-treated and hydroxyapatite-coated titanium) were surgically inserted into femoral and tibial metaphyseal cancellous bone (16 per implant type; interference fit) and in tibial cortices at three diaphyseal locations (24 per implant type; line-to-line fit) in eight skeletally mature sheep. At 12 weeks postoperatively, bones were excised to assess osseointegration of AHT and PCHA implants via biomechanical push-through tests, micro-CT, and histomorphometry. Bone composition and remodeling patterns in adult sheep are similar to that of humans, and this model enables comparison of implants with ex vivo outcomes that are not permissible with humans. Comparisons of primary and secondary outcomes were undertaken with linear mixed-effects models that were developed for the cortical and cancellous groups separately and that included a random effect of animals, covariates to adjust for preoperative bodyweight, and implant location (left/right limb, femoral/tibial cancellous, cortical diaphyseal region, and medial/lateral cortex) as appropriate. Significance was set at an alpha of 0.05. RESULTS: The estimated marginal mean interfacial shear strength for cancellous bone, adjusted for covariates, was 1.6 MPa greater for AHT implants (9.3 MPa) than for PCHA implants (7.7 MPa) (95% CI 0.5 to 2.8; p = 0.006). Similarly, the estimated marginal mean interfacial shear strength for cortical bone, adjusted for covariates, was 6.6 MPa greater for AHT implants (25.5 MPa) than for PCHA implants (18.9 MPa) (95% CI 5.0 to 8.1; p < 0.001). No difference in the implant-bone percent intersection surface was detected for cancellous sites (cancellous AHT 55.1% and PCHA 58.7%; adjusted difference of estimated marginal mean -3.6% [95% CI -8.1% to 0.9%]; p = 0.11). In cortical bone, the estimated marginal mean percent intersection surface at the medial site, adjusted for covariates, was 11.8% higher for AHT implants (58.1%) than for PCHA (46.2% [95% CI 7.1% to 16.6%]; p < 0.001) and was not different at the lateral site (AHT 75.8% and PCHA 74.9%; adjusted difference of estimated marginal mean 0.9% [95% CI -3.8% to 5.7%]; p = 0.70). CONCLUSION: These data suggest there is stronger integration of bone on the AHT surface than on the PCHA surface at 12 weeks postimplantation in this sheep model. CLINICAL RELEVANCE: Given that the AHT implants formed a more robust interface with cortical and cancellous bone than the PCHA implants, a clinical noninferiority study using hip stems with identical geometries can now be performed to compare the same surfaces used in this study. The results of this preclinical study provide an ethical baseline to proceed with such a clinical study given the potential of the alkaline heat-treated surface to reduce periprosthetic joint infection and enhance implant osseointegration.


Asunto(s)
Antiinfecciosos , Oseointegración , Animales , Antiinfecciosos/farmacología , Durapatita/farmacología , Humanos , Prótesis e Implantes , Ovinos , Propiedades de Superficie , Titanio/farmacología
14.
Pediatr Radiol ; 52(7): 1326-1337, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35169882

RESUMEN

BACKGROUND: Conventional chest and abdominal MRI require breath-holds to reduce motion artifacts. Neonates and infants require general anesthesia with intubation to enable breath-held acquisitions. OBJECTIVE: We aimed to validate a free-breathing approach to reduce general anesthesia using a motion-insensitive radial acquisition with respiratory gating. MATERIALS AND METHODS: We retrospectively enrolled children <3 years old who were referred for MRI of the chest or abdomen. They were divided into two groups according to MRI protocol: (1) breath-held scans under general anesthesia with T2-weighted single-shot fast spin-echo (SSFSE) and contrast-enhanced T1-weighted modified Dixon, and (2) free-breathing scans using radial sequences (T2-W MultiVane XD and contrast-enhanced T1-W three-dimensional [3-D] Vane XD). Two readers graded image quality and motion artifacts. RESULTS: We included 23 studies in the free-breathing cohort and 22 in the breath-hold cohort. The overall imaging scores for the free-breathing radial T2-W sequence were similar to the scores for the breath-held T2-W SSFSE sequence (chest, 3.6 vs. 3.2, P=0.07; abdomen, 3.9 vs. 3.7, P=0.66). The free-breathing 3-D radial T1-W sequence also had image quality scores that were similar to the breath-held T1-W sequence (chest, 4.0 vs. 3.0, P=0.06; abdomen, 3.7 vs. 3.9, P=0.15). Increased motion was seen in the abdomen on the radial T2-W sequence (P<0.001), but increased motion was not different in the chest (P=0.73) or in contrast-enhanced T1-W sequences (chest, P=0.39; abdomen, P=0.15). The mean total sequence time was longer in free-breathing compared to breath-held exams (P<0.01); however, this did not translate to longer overall exam times (P=0.94). CONCLUSION: Motion-insensitive radial sequences used for infants and neonates were of similar image quality to breath-held sequences and had decreased sedation and intubation.


Asunto(s)
Anestesia , Imagen por Resonancia Magnética , Artefactos , Niño , Preescolar , Medios de Contraste , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Lactante , Recién Nacido , Imagen por Resonancia Magnética/métodos , Respiración , Estudios Retrospectivos
15.
Harm Reduct J ; 19(1): 11, 2022 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-35120550

RESUMEN

BACKGROUND: Excessive alcohol consumption is an important risk factor for increased morbidity, mortality and other social harms globally. Televised sport allows the promotion of alcoholic drinks to a large and often young audience, and thus can be used to develop new markets for alcohol in low- and middle-income countries. This study aimed to analyse the alcohol advertising displayed during televised English Premier League (EPL) games, which is widely viewed in Ethiopia, and are particularly popular among young people. METHODS: Nineteen live televised EPL football matches broadcast in Ethiopia on the SuperSport channels over 4 weeks of the 2018/19 season were digitally recorded from the digital satellite television. Exposure to alcohol advertising was measured by calculating the total elapsed time duration with the alcohol content from the pre-match to the end of the post-game period of the broadcast. RESULTS: Data were available for a total of 2451 min broadcast time. Alcohol advertising accounted for 205.2 min (8.4%) with a mean duration of 10.8 min per match (range 5.5 to 22.6). The dominant format of alcohol advertisement was the display of logos associated with an alcoholic drink on the television (TV) screen, which accounted for approximately 43% of the total alcohol advertising time. This was followed by pitch side virtual display (17.7%) and a glass of alcohol drink on the TV screen (17.6%). Over three quarters of alcoholic drink advertising (77.7%) was during active football playing time. None of the advertisements on the televised football games showed cigarettes. CONCLUSION: There is a high frequency of exposure to alcohol advertising during televised EPL matches in Ethiopia. It is important to ensure that the newly introduced domestic ban on alcohol advertising is also applied to foreign satellite broadcasters. This is likely to have relevance to other sub-Saharan African countries in promoting public health strategies to reduce harm from alcohol consumption.


Asunto(s)
Publicidad , Fútbol Americano , Adolescente , Bebidas Alcohólicas , Etiopía , Humanos , Televisión
16.
J Biomech Eng ; 143(12)2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34729587

RESUMEN

Biofluids comprises a core topical domain for modern biomedical engineering education. Like other biomedical topic areas, biofluids education must address highly interdisciplinary and applied topics. Concept/problem-based active learning approaches can provide effective avenues to teach such diverse and applied topics. However, with the heterogeneity within biofluids topics across cellular, physiological, and/or extra-organismal scales, it is important to develop active learning content that enables students to explore concepts with appropriate context. This challenge is further complicated by the need to administer such content remotely (due to the Covid-19 pandemic). Here, we outline our design process and implementation experience for simulation-based active learning modules for a newly developed physiological biofluids course. We share the overall design approach, with two example cases of simulation-based concept exploration: (a) arterial Windkessel effects and lumped parameter hemodynamic analysis; and (b) curvature-induced helical flow in human aorta illustrated using four-dimensional (4D) flow magnetic resonance imaging (MRI). Evidence from student survey ratings, student comments and feedback, and monitoring student performance for course deliverables indicate positive student response toward these modules, and efficacy of the modules in enabling student learning. Based on our design and implementation experience, we argue that simulation-based approaches can enable active learning of biofluids through remote and online learning modalities.


Asunto(s)
Pandemias , Aprendizaje Basado en Problemas , Estudiantes
17.
J Biomech Eng ; 143(4)2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33156343

RESUMEN

Coronary artery atherosclerosis is a local, multifactorial, complex disease, and the leading cause of death in the US. Complex interactions between biochemical transport and biomechanical forces influence disease growth. Wall shear stress (WSS) affects coronary artery atherosclerosis by inducing endothelial cell mechanotransduction and by controlling the near-wall transport processes involved in atherosclerosis. Each of these processes is controlled by WSS differently and therefore has complicated the interpretation of WSS in atherosclerosis. In this paper, we present a comprehensive theory for WSS in atherosclerosis. First, a short review of shear stress-mediated mechanotransduction in atherosclerosis was presented. Next, subject-specific computational fluid dynamics (CFD) simulations were performed in ten coronary artery models of diseased and healthy subjects. Biochemical-specific mass transport models were developed to study low-density lipoprotein, nitric oxide, adenosine triphosphate, oxygen, monocyte chemoattractant protein-1, and monocyte transport. The transport results were compared with WSS vectors and WSS Lagrangian coherent structures (WSS LCS). High WSS magnitude protected against atherosclerosis by increasing the production or flux of atheroprotective biochemicals and decreasing the near-wall localization of atherogenic biochemicals. Low WSS magnitude promoted atherosclerosis by increasing atherogenic biochemical localization. Finally, the attracting WSS LCS's role was more complex where it promoted or prevented atherosclerosis based on different biochemicals. We present a summary of the different pathways by which WSS influences coronary artery atherosclerosis and compare different mechanotransduction and biotransport mechanisms.


Asunto(s)
Mecanotransducción Celular , Vasos Coronarios
18.
Pediatr Radiol ; 51(7): 1192-1201, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33566124

RESUMEN

BACKGROUND: Conventional pediatric volumetric MRI acquisitions of a short-axis stack typically require multiple breath-holds under anesthesia. OBJECTIVE: Here, we aimed to validate a vendor-optimized compressed-sensing approach to reduce scan time during short-axis balanced steady-state free precession (bSSFP) cine imaging. MATERIALS AND METHODS: Imaging was performed in 28 patients (16±9 years) in this study on a commercial 3-tesla (T) scanner using retrospective electrocardiogram-gated cine bSSFP. Cine short-axis images covering both ventricles were acquired with conventional parallel imaging and a vendor-optimized parallel imaging/compressed-sensing approach. Qualitative Likert scoring for blood-myocardial contrast, edge definition, and presence of artifact was performed by two experienced radiologists. Quantitative comparisons were performed including biventricular size and function. A paired t-test was used to detect significant differences (P<0.05). RESULTS: Scan duration was 7±2 s/slice for conventional imaging (147±33 s total) vs. 4±2 s/slice for compressed sensing (83±28 s total). No significant differences were found with qualitative image scores for blood-myocardial contrast, edge definition, and presence of artifact. No significant differences were found in volumetric analysis between the two sequences. The number of breath-holds was 10±4 for conventional imaging and 5±3 for compressed sensing. CONCLUSION: Compressed sensing allowed for a 50% reduction in the number of breath-holds and a 43% reduction in the total scan time without differences in the qualitative or quantitative measurements as compared to the conventional technique.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética , Niño , Humanos , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados , Estudios Retrospectivos , Adulto Joven
19.
Int J Mol Sci ; 22(5)2021 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-33800498

RESUMEN

The recently identified nonsymbiotic hemoglobin gene MtGlb1-2 of the legume Medicago truncatula possesses unique properties as it generates four alternative splice forms encoding proteins with one or two heme domains. Here we investigate the ligand binding kinetics of MtGlb1-2.1 and MtGlb1-2.4, bearing two hemes and one heme, respectively. Unexpectedly, the overall time-course of ligand rebinding was unusually fast. Thus, we complemented nanosecond laser flash photolysis kinetics with data collected with a hybrid femtosecond-nanosecond pump-probe setup. Most photodissociated ligands are rebound geminately within a few nanoseconds, which leads to rates of the bimolecular rebinding to pentacoordinate species in the 108 M-1s-1 range. Binding of the distal histidine to the heme competes with CO rebinding with extremely high rates (kh ~ 105 s-1). Histidine dissociation from the heme occurs with comparable rates, thus resulting in moderate equilibrium binding constants (KH ~ 1). The rate constants for ligation and deligation of distal histidine to the heme are the highest reported for any plant or vertebrate globin. The combination of microscopic rates results in unusually high overall ligand binding rate constants, a fact that contributes to explaining at the mechanistic level the extremely high reactivity of these proteins toward the physiological ligands oxygen, nitric oxide and nitrite.


Asunto(s)
Hemo/química , Hemoglobinas/química , Medicago truncatula/química , Proteínas de Plantas/química , Histidina/química , Unión Proteica
20.
Am J Physiol Heart Circ Physiol ; 318(5): H1032-H1040, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-32167782

RESUMEN

The Fontan circulation is characterized as a nonpulsatile flow propagation without a pressure-generating ventricle. However, flow through the Fontan circulation still exhibits oscillatory waves as a result of pressure changes generated by the systemic single ventricle. Identification of discrete flow patterns through the Fontan circuit may be important to understand single ventricle performance. Ninety-seven patients with Fontan circulation underwent phase-contrast MRI of the right pulmonary artery, yielding subject-specific flow waveforms. Principal component (PC) analysis was performed on preprocessed flow waveforms. Principal components were then correlated with standard MRI indices of function, volume, and aortopulmonary collateral flow. The first principal component (PC) described systolic versus diastolic-dominant flow through the Fontan circulation, accounting for 31.3% of the variance in all waveforms. The first PC correlated with end-diastolic volume (R = 0.34, P = 0.001), and end-systolic volume (R = 0.30, P = 0.003), cardiac index (R = 0.51, P < 0.001), and the amount of aortopulmonary collateral flow (R = 0.25, P = 0.027)-lower ventricular volumes and a smaller volume of collateral flow-were associated with diastolic-dominant cavopulmonary flow. The second PC accounted for 19.5% of variance and described late diastolic acceleration versus deceleration and correlated with ejection fraction-diastolic deceleration was associated with higher ejection fraction. Principal components describing the diastolic flow variations in pulmonary arteries are related to the single ventricle function and volumes. Particularly, diastolic-dominant flow without late acceleration appears to be related to preserved ventricular volume and function, respectively.NEW & NOTEWORTHY The exact physiological significance of flow oscillations of phasic and temporal flow variations in Fontan circulation is unknown. With the use of principal component analysis, we discovered that flow variations in the right pulmonary artery of Fontan patients are related to the single ventricle function and volumes. Particularly, diastolic-dominant flow without late acceleration appears to be related to more ideal ventricular volume and systolic function, respectively.


Asunto(s)
Procedimiento de Fontan/efectos adversos , Ventrículos Cardíacos/fisiopatología , Hemodinámica , Modelos Cardiovasculares , Complicaciones Posoperatorias/fisiopatología , Arteria Pulmonar/fisiopatología , Adolescente , Niño , Circulación Coronaria , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Masculino , Contracción Miocárdica , Modelación Específica para el Paciente , Complicaciones Posoperatorias/diagnóstico por imagen , Análisis de Componente Principal , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA