Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 47(10): 1418-1422, 2024 10.
Artículo en Inglés | MEDLINE | ID: mdl-39037199

RESUMEN

Electrical storm (ES) is among the most fearsome events in patients in waiting list for heart transplantation (HT) and catheter ablation (CA) demonstrated to be effective in reduce the arrhythmic burden. However, selection criteria for CA suitability in this specific population have never been addressed before. We retrospectively enrolled 36 patients (mean age 51 ± 8 years; 83% men) waiting HT referred to our department for ES resistant to antiarrhythmic drugs and percutaneous stellate ganglion blockade. Twenty patients were judged suitable for VT ablation according to specific criteria including absence of increased arrhythmic burden secondary to volume overload and hemodynamic decompensation; expected CA outcome favorable due to etiology of the cardiomyopathy, no need for coronary revascularization and technical feasibility of the procedure. The pre-emptive use of mechanical circulatory supports (MCS) were discussed integrating the PAINESD score with additional clinical and hemodynamic parameters. Acute procedural success was accounted in 85% of cases with only two major complications. The CA group reported lower length of in-hospital stay after CA suitability evaluation (56 ± 17 vs. 131 ± 64 days, p = .004). Furthermore, at a mean follow-up of 703 ± 145 days, this group showed reduction of ventricular arrhythmia (VA) recurrence leading to implantable cardioverter defibrillator shock (4 vs. 8, p = .051) and underwent HT with a lower level of urgency (0 vs. 6 patients needed for UNOS1 status upgrade). Respectively, one patient of the CA group and two patients of the conservative group died (p = .839). At the end of follow-up, eight patients underwent heart transplantation (p = .964) while four patients underwent Left Ventricular Assist device (LVAD) implantation (p = .440). This pilot study should be a proof for further studies exploring CA of VAs as a possible bridge therapy to HT.


Asunto(s)
Ablación por Catéter , Trasplante de Corazón , Taquicardia Ventricular , Listas de Espera , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Ablación por Catéter/métodos , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/fisiopatología , Selección de Paciente , Resultado del Tratamiento
2.
Artif Organs ; 48(5): 525-535, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38213270

RESUMEN

BACKGROUND: Left ventricular assist device (L-VAD) implantation is increasingly used in patients with heart failure (HF) and most patients also have an implantable cardioverter defibrillator (ICD). Limited data are available on the incidence of ICD therapies and complications in this special setting. The aim of this study was to analyze the real-world incidence and predictors of ICD therapies, complications and interactions between ICD and L-VAD. METHODS: We conducted a multicenter retrospective observational study in patients with advanced HF implanted with ICD and a continuous-flow L-VAD, followed-up in five advanced HF centers in Northern Italy. RESULTS: A total of 234 patients (89.7% male, median age 59, 48.3% with ischemic etiology) were enrolled. After a median follow-up of 21 months, 66 patients (28.2%) experienced an appropriate ICD therapy, 22 patients (9.4%) an inappropriate ICD therapy, and 17 patients (7.3%) suffered from an interaction between ICD and L-VAD. The composite outcome of all ICD-related complications was reported in 41 patients (17.5%), and 121 (51.7%) experienced an L-VAD-related complication. At multivariable analysis, an active ventricular tachycardia (VT) zone and a prior ICD generator replacement were independent predictors of ICD therapies and of total ICD-related complications, respectively. CONCLUSIONS: Real-world patients with both L-VAD and ICD experience a high rate of ICD therapies and complications. Our findings suggest the importance of tailoring device programming in order to minimize the incidence of unnecessary ICD therapies, thus sparing the need for ICD generator replacement, a procedure associated to a high risk of complications.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Corazón Auxiliar , Taquicardia Ventricular , Femenino , Humanos , Masculino , Arritmias Cardíacas/etiología , Desfibriladores Implantables/efectos adversos , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/etiología , Corazón Auxiliar/efectos adversos , Estudios Retrospectivos , Taquicardia Ventricular/etiología , Resultado del Tratamiento , Persona de Mediana Edad
3.
Medicina (Kaunas) ; 60(5)2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38793002

RESUMEN

Over the past decade, remote monitoring (RM) has become an increasingly popular way to improve healthcare and health outcomes. Modern cardiac implantable electronic devices (CIEDs) are capable of recording an increasing amount of data related to CIED function, arrhythmias, physiological status and hemodynamic parameters, providing in-depth and updated information on patient cardiovascular function. The extensive use of RM for patients with CIED allows for early diagnosis and rapid assessment of relevant issues, both clinical and technical, as well as replacing outpatient follow-up improving overall management without compromise safety. This approach is recommended by current guidelines for all eligible patients affected by different chronic cardiac conditions including either brady- and tachy-arrhythmias and heart failure. Beyond to clinical advantages, RM has demonstrated cost-effectiveness and is associated with elevated levels of patient satisfaction. Future perspectives include improving security, interoperability and diagnostic power as well as to engage patients with digital health technology. This review aims to update existing data concerning clinical outcomes in patients managed with RM in the wide spectrum of cardiac arrhythmias and Hear Failure (HF), disclosing also about safety, effectiveness, patient satisfaction and cost-saving.


Asunto(s)
Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/diagnóstico , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Monitoreo Fisiológico/métodos , Telemedicina/tendencias , Desfibriladores Implantables/normas
4.
J Cardiovasc Electrophysiol ; 34(4): 947-956, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36709469

RESUMEN

INTRODUCTION: Thoracic impedance (TI) drops measured by implantable cardioverter-defibrillators (ICDs) have been reported to correlate with ventricular tachycardia/fibrillation (VT/VF). The aim of our study was to assess the temporal association of decreasing TI trends with VT/VF episodes through a longitudinal analysis of daily remote monitoring data from ICDs and cardiac resynchronization therapy defibrillators (CRT-Ds). METHODS AND RESULTS: Retrospective data from 2384 patients were randomized 1:1 into a derivation or validation cohort. The TI decrease rate was defined as the percentage of rolling weeks with a continuously decreasing TI trend. The derivation cohort was used to determine a TI decrease rate threshold for a ≥99% specificity of arrhythmia prediction. The associated risk of VT/VF episodes was estimated in the validation cohort by dividing the available follow-up into 60-day assessment intervals. Analyses were performed separately for 1354 ICD and 1030 CRT-D patients. During a median follow-up of 2.0 years, 727 patients (30.4%) experienced 3298 confirmed VT/VF episodes. In the ICD group, a TI decrease rate of >60% was associated with a higher risk of VT/VF episode in a 60-day assessment interval (stratified hazard ratio, 1.42; 95% confidence interval (CI), 1.05-1.92; p = .023). The TI decrease preceded (40.8%) or followed (59.2%) the VT/VF episodes. In the CRT-D group, no association between TI decrease and VT/VF episodes was observed (p = .84). CONCLUSION: In our longitudinal analysis, TI decrease was associated with VT/VF episodes only in ICD patients. Preventive interventions may be difficult since episodes can occur before or after TI decrease.


Asunto(s)
Arritmias Cardíacas , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/terapia , Impedancia Eléctrica , Estudios Retrospectivos , Fibrilación Ventricular , Desfibriladores Implantables
5.
Nutr Metab Cardiovasc Dis ; 33(7): 1323-1329, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37248142

RESUMEN

BACKGROUND AND AIMS: Interest in the role of atrial substrate in maintaining Atrial Fibrillation (AF) is growing. Fibrosis is the culprit in the electrical derangement of the myocytes. Many cardiovascular risk factors are known to be linked to atrial scarring; among them Uric Acid (UA) is emerging. The purpose of our study is to find whether UA is associated with Left Atrium (LA) with pathological substrate. METHODS AND RESULTS: 81 patients who underwent radiofrequency transcatheter ablation for nonvalvular AF at the cardiological department of the Niguarda Hospital were enrolled in an observational, cross-sectional, single-center study. UA levels were analysed before the procedure. High density electroanatomic mapping of the LA was performed and patients were divided according to the presence or not of areas of pathological substrate (bipolar voltage <0.5 mV in sinus rhythm). 19 patients showed a LA with pathological substrate. These subjects showed a significant higher prevalence of persistent phenotype of AF (84.2 vs. 25.8%, p < 0.001). UA levels were significantly higher in the group of patients with LA with pathological substrate (6.8 ± 1.9 vs 5.3 ± 1.4 mg/dL, p < 0.001) as well as the prevalence of hyperuricemia (26.5 vs. 6.5%, p = 0.021). The association between uric acid LA with pathological substrate remains significant even after correction for confounding factors (age, left ventricular dysfunction, valvular disease, arrythmia phenotype and furosemide use) and also when the ratio UA/creatinine was evaluated. CONCLUSIONS: In a population of patients who underwent AF ablation, higher UA levels were significantly associated with pathological LA substrate at electro-anatomical mapping.


Asunto(s)
Fibrilación Atrial , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ácido Úrico , Estudios Transversales , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/patología , Fibrosis
6.
Mol Ther ; 30(2): 550-563, 2022 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-34478871

RESUMEN

CD19-directed chimeric antigen receptor (CAR) T cells have yielded impressive response rates in refractory/relapse B cell acute lymphoblastic leukemia (B-ALL); however, most patients ultimately relapse due to poor CAR T cell persistence or resistance of either CD19+ or CD19- B-ALL clones. CD22 is a pan-B marker whose expression is maintained in both CD19+ and CD19- relapses. CD22-CAR T cells have been clinically used in B-ALL patients, although relapse also occurs. T cells engineered with a tandem CAR (Tan-CAR) containing in a single construct both CD19 and CD22 scFvs may be advantageous in achieving higher remission rates and/or preventing antigen loss. We have generated and functionally validated using cutting-edge assays a 4-1BB-based CD22/CD19 Tan-CAR using in-house-developed novel CD19 and CD22 scFvs. Tan-CAR-expressing T cells showed similar in vitro expansion to CD19-CAR T cells with no increase in tonic signaling. CRISPR-Cas9-edited B-ALL cells confirmed the bispecificity of the Tan-CAR. Tan-CAR was as efficient as CD19-CAR in vitro and in vivo using B-ALL cell lines, patient samples, and patient-derived xenografts (PDXs). Strikingly, the robust antileukemic activity of the Tan-CAR was slightly more effective in controlling the disease in long-term follow-up PDX models. This Tan-CAR construct warrants a clinical appraisal to test whether simultaneous targeting of CD19 and CD22 enhances leukemia eradication and reduces/delays relapse rates and antigen loss.


Asunto(s)
Receptores Quiméricos de Antígenos , Antígenos CD19 , Linfocitos B , Humanos , Inmunoterapia Adoptiva , Receptores Quiméricos de Antígenos/metabolismo , Lectina 2 Similar a Ig de Unión al Ácido Siálico/genética , Linfocitos T
7.
J Cardiovasc Electrophysiol ; 32(9): 2528-2535, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34252991

RESUMEN

INTRODUCTION: Factors influencing malignant arrhythmia onset are not fully understood. We explored the circadian periodicity of ventricular arrhythmias (VAs) in patients with implantable cardioverter and cardiac resynchronization defibrillators (ICD/CRT-D). METHODS: Time, morphology (monomorphic/polymorphic), and mode of termination (anti-tachycardia pacing [ATP] or shock) of VAs stored in a database of remote monitoring data were adjudicated. Episodes were grouped in six 4-h timeslots from 00:00 to 24:00. Circadian distributions and adjusted marginal odds ratios (ORs), with 95% confidence interval (CI), were analyzed using mixed-effect models and logit generalized estimating equations, respectively, to account for within-subject correlation of multiple episodes. RESULTS: Among 1303 VA episodes from 446 patients (63% ICD and 37% CRT-D), 120 (9%) self-extinguished, and 842 (65%) were terminated by ATP, 343 (26%) by shock. VAs clustered from 08:00 to 16:00 with 44% of episodes, as compared with 22% from 00:00 to 08:00 (p < .001) and 34% from 16:00 to 24:00 (p = .005). Episodes were more likely to be polymorphic at night with an adjusted marginal OR of 1.66 (CI, 1.15-2.40; p = .007) at 00:00-04:00 versus other timeslots. Episodes were less likely to be terminated by ATP in the 00:00-04:00 (success-to-failure ratio, 0.67; CI, 0.46-0.98; p = .039) and 08:00-12:00 (0.70; CI, 0.51-0.96; p = .02) timeslots, and most likely to be terminated by ATP between 12:00 and 16:00 (success-to-failure ratio 1.42; CI, 1.06-1.91; p = .02). CONCLUSION: VAs did not distribute uniformly over the 24 h, with a majority of episodes occurring from 08:00 to 16:00. Nocturnal episodes were more likely to be polymorphic. The efficacy of ATP depended on the time of delivery.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado del Tratamiento
8.
Blood ; 133(21): 2291-2304, 2019 05 23.
Artículo en Inglés | MEDLINE | ID: mdl-30796021

RESUMEN

Relapsed/refractory T-cell acute lymphoblastic leukemia (T-ALL) has a dismal outcome, and no effective targeted immunotherapies for T-ALL exist. The extension of chimeric antigen receptor (CAR) T cells (CARTs) to T-ALL remains challenging because the shared expression of target antigens between CARTs and T-ALL blasts leads to CART fratricide. CD1a is exclusively expressed in cortical T-ALL (coT-ALL), a major subset of T-ALL, and retained at relapse. This article reports that the expression of CD1a is mainly restricted to developing cortical thymocytes, and neither CD34+ progenitors nor T cells express CD1a during ontogeny, confining the risk of on-target/off-tumor toxicity. We thus developed and preclinically validated a CD1a-specific CAR with robust and specific cytotoxicity in vitro and antileukemic activity in vivo in xenograft models of coT-ALL, using both cell lines and coT-ALL patient-derived primary blasts. CD1a-CARTs are fratricide resistant, persist long term in vivo (retaining antileukemic activity in re-challenge experiments), and respond to viral antigens. Our data support the therapeutic and safe use of fratricide-resistant CD1a-CARTs for relapsed/refractory coT-ALL.


Asunto(s)
Antígenos CD1/inmunología , Resistencia a Antineoplásicos/inmunología , Inmunoterapia Adoptiva , Leucemia-Linfoma Linfoblástico de Células T Precursoras , Receptores Quiméricos de Antígenos/inmunología , Animales , Humanos , Células Jurkat , Ratones , Leucemia-Linfoma Linfoblástico de Células T Precursoras/inmunología , Leucemia-Linfoma Linfoblástico de Células T Precursoras/patología , Leucemia-Linfoma Linfoblástico de Células T Precursoras/terapia , Ensayos Antitumor por Modelo de Xenoinjerto
11.
Clin Case Rep ; 12(4): e8745, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38659502

RESUMEN

A 46-year-old woman with congenitally corrected transposition of the great arteries (ccTGA) associated with dextrocardia, situs viscerus inversus, and left superior vena cava persistence presented with an incessant supraventricular tachycardia. Electrophysiological study was not conclusive in differential diagnosis of atrial tachycardia versus atypical atrioventricular (AV) nodal reentrant tachycardia, also due to the unconventional anatomy of the coronary sinus. By a comprehensive mapping of cardiac chambers, a double side slow-pathway was localized in both atrial chambers and subsequently ablated by radiofrequency delivery without tachycardia changes. Aortic root and cusps were devoid of electrical activity. The muscular part of the sub-pulmonary ventricle at the level of interatrial septum showed an earliest activation signal of -90 ms and ablation of this site was effective in abolish the tachycardia. This is the first case to report technical concerns of septal atrial tachycardia ablation in ccTGA associated with multiple anatomical malformations. Moreover, some peculiarities have been reported for the first time including the presence of double-side AV nodal slow-pathway and atypical localization of the tachycardia origin into the muscular part of the sub-pulmonary ventricle instead of posterior pulmonary cusp.

12.
J Clin Med ; 13(2)2024 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-38256590

RESUMEN

Arrhythmogenic cardiomyopathy (ACM) is a heart disease characterized by a fibrotic replacement of myocardial tissue and a consequent predisposition to ventricular arrhythmic events, especially in the young. Post-mortem studies and the subsequent diffusion of cardiac MRI have shown that left ventricular involvement in arrhythmogenic cardiomyopathy is common and often develops early. Regarding the arrhythmic risk stratification, the current scores underestimate the arrhythmic risk of patients with arrhythmogenic cardiomyopathy with left involvement. Indeed, the data on arrhythmic risk stratification in this group of patients are contradictory and not exhaustive, with the consequence of not correctly identifying patients at a high arrhythmic risk who deserve protection from arrhythmic death. We propose a literature review on arrhythmic risk stratification in patients with ACM and left involvement to identify the main features associated with an increased arrhythmic risk in this group of patients.

13.
J Cardiovasc Dev Dis ; 11(7)2024 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-39057642

RESUMEN

Cardiac amyloidosis is the most frequent infiltrative disease caused by the deposition of misfolded proteins in the cardiac tissue, leading to heart failure, brady- and tachyarrhythmia and death. Conduction disorders, atrial fibrillation (AF) and ventricular arrhythmia (VA) significantly impact patient outcomes and demand recognition. However, several issues remain unresolved regarding early diagnosis and optimal management. Extreme bradycardia is the most common cause of arrhythmic death, while fast and sustained VAs can be found even in the early phases of the disease. Risk stratification and the prevention of sudden cardiac death are therefore to be considered in these patients, although the time for defibrillator implantation is still a subject of debate. Moreover, atrial impairment due to amyloid fibrils is associated with an increased risk of AF resistant to antiarrhythmic therapy, as well as recurrent thromboembolic events despite adequate anticoagulation. In the last few years, the aging of the population and progressive improvements in imaging methods have led to increases in the diagnosis of cardiac amyloidosis. Novel therapies have been developed to improve patients' functional status, quality of life and mortality, without data regarding their effect on arrhythmia prevention. In this review, we consider the latest evidence regarding the arrhythmic risk stratification of cardiac amyloidosis, as well as the available therapeutic strategies.

14.
Diagnostics (Basel) ; 14(2)2024 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-38248058

RESUMEN

Fluoroscopy has always been the cornerstone imaging method of interventional cardiology procedures. However, radiation exposure is linked to an increased risk of malignancies and multiorgan diseases. The medical team is even more exposed to X-rays, and a higher incidence of malignancies was reported in this professional group. In the last years, X-ray exposure has increased rapidly, involving, above all, the medical team and young patients and forcing alternative fluoroless imaging methods. In cardiac electrophysiology (EP) and pacing, the advent of 3D electroanatomic mapping systems with dedicated catheters has allowed real-time, high-density reconstruction of both heart anatomy and electrical activity, significantly reducing the use of fluoroscopy. In addition, the diffusion of intracardiac echocardiography has provided high anatomical resolution of moving cardiac structures, providing intraprocedural guidance for more complex catheter ablation procedures. These methods have largely demonstrated safety and effectiveness, allowing for a dramatic reduction in X-ray delivery in most arrhythmias' ablations. However, some technical concerns, as well as higher costs, currently do not allow their spread out in EP labs and limit their use to only procedures that are considered highly complex and time-consuming and in young patients. In this review, we aim to update the current employment of fluoroless imaging in different EP procedures, focusing on its strengths and weaknesses.

15.
J Cardiovasc Med (Hagerstown) ; 25(6): 450-456, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38625833

RESUMEN

BACKGROUND: Atrioventricular block (AVB) is a frequent complication in patients undergoing transcatheter aortic valve implantation (TAVI). Right apex ventricular pacing (RVP) represents the standard treatment but may induce cardiomyopathy over the long term. Left bundle branch area pacing (LBBAP) is a promising alternative, minimizing the risk of desynchrony. However, available evidence with LBBAP after TAVI is still low. OBJECTIVE: To assess the feasibility and safety of LBBAP for AVB post-TAVI compared with RVP. METHODS: Consecutive patients developing AVB early after TAVI were enrolled between 1 January 2022 and 31 December 2022 at three high-volume hospitals and received LBBAP or RVP. Data on procedure and at short-term follow-up (at least 3 months) were collected. RESULTS: A total of 38 patients (61% men, mean age 83 ±â€Š6 years) were included; 20 patients (53%) received LBBAP. Procedural success was obtained in all patients according to chosen pacing strategy. Electrical pacing performance at implant and after a mean follow-up of 4.2 ±â€Š2.8 months was clinically equivalent for both pacing modalities. In the LBBAP group, procedural time was longer (70 ±â€Š17 versus 58 ±â€Š15 min in the RVP group, P  = 0.02) and paced QRS was shorter (120 ±â€Š19 versus 155 ±â€Š12 ms at implant, P  < 0.001; 119 ±â€Š18 versus 157 ±â€Š9 ms at follow-up, P  < 0.001). Complication rates did not differ between the two groups. CONCLUSION: In patients with AVB after TAVI, LBBAP is feasible and safe, resulting in a narrow QRS duration, either acutely and during the follow-up, compared with RVP. Further studies are needed to evaluate if LBBAP reduces pacing-induced cardiomyopathy in this clinical setting.


Asunto(s)
Estenosis de la Válvula Aórtica , Bloqueo Atrioventricular , Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Estudios de Factibilidad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Femenino , Anciano de 80 o más Años , Anciano , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/diagnóstico , Resultado del Tratamiento , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Fascículo Atrioventricular/fisiopatología , Factores de Tiempo , Letonia , Factores de Riesgo , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Frecuencia Cardíaca
16.
Heart Rhythm ; 21(9): 1630-1639, 2024 09.
Artículo en Inglés | MEDLINE | ID: mdl-38493989

RESUMEN

BACKGROUND: Atrial high-rate episodes (AHREs) are frequent in patients with cardiac implantable electronic devices. A decrease in device-detected P-wave amplitude may be an indicator of periods of increased risk of AHRE. OBJECTIVE: The objective of this study was to assess the association between P-wave amplitude and AHRE incidence. METHODS: Remote monitoring data from 2579 patients with no history of atrial fibrillation (23% pacemakers and 77% implantable cardioverter-defibrillators, of which 40% provided cardiac resynchronization therapy) were used to calculate the mean P-wave amplitude during 1 month after implantation. The association with AHRE incidence according to 4 strata of daily burden duration (≥15 minutes, ≥6 hours, ≥24 hours, ≥7 days) was investigated by adjusting the hazard ratio with the CHA2DS2-VASc score. RESULTS: The adjusted hazard ratio for 1-mV lower mean P-wave amplitude during the first month increased from 1.10 (95% confidence interval [CI], 1.05-1.15; P < .001) to 1.18 (CI, 1.09-1.28; P < .001) with AHRE duration strata from ≥15 minutes to ≥7 days independent of the CHA2DS2-VASc score. Of 871 patients with AHREs, those with 1-month P-wave amplitude <2.45 mV had an adjusted hazard ratio of 1.51 (CI, 1.19-1.91; P = .001) for progression of AHREs from ≥15 minutes to ≥7 days compared with those with 1-month P-wave amplitude ≥2.45 mV. Device-detected P-wave amplitudes decreased linearly during the 1 year before the first AHRE by 7.3% (CI, 5.1%-9.5%; P < .001 vs patients without AHRE). CONCLUSION: Device-detected P-wave amplitudes <2.45 mV were associated with an increased risk of AHRE onset and progression to persistent forms of AHRE independent of the patient's risk profile.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Humanos , Femenino , Masculino , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Anciano , Incidencia , Progresión de la Enfermedad , Medición de Riesgo/métodos , Atrios Cardíacos/fisiopatología , Marcapaso Artificial , Frecuencia Cardíaca/fisiología , Factores de Riesgo , Persona de Mediana Edad , Tecnología de Sensores Remotos/instrumentación , Estudios de Seguimiento
17.
Blood Press ; 22(6): 355-61, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23862738

RESUMEN

AIMS: Diabetes mellitus is characterized by structural and functional alterations of the large- and medium-size arteries. Whether blood glucose variability, i.e. the glycemic oscillations occurring during the 24-h period, represents a risk factor for vascular alterations additional to and independent on HbA1c in type 1 diabetes mellitus is still undefined. The present study was carried out with the aim at investigating the impact of different measures of blood glucose variability on arterial structure and function. We studied 17 non-complicated type 1 diabetic patients (11 males, six females) with an age of 40.8 ± 7.6 years (mean ± SD). In each patient, 24-h glucose profile was obtained by continuous glucose monitoring system and glucose variability was expressed as mean ± SD of 24-h blood glucose levels, mean amplitude of glycemic excursions and postprandial hyperglycemic spikes. Arterial structure and function was measured as carotid IMT and stiffness. MAJOR FINDINGS: The different approaches to assessing blood glucose variability well correlated between and with HbA1c. Carotid IMT and stiffness showed significant correlations with age, blood pressure, heart rate and daily insulin intake but a non- significant correlation with blood glucose variability. PRINCIPAL CONCLUSION: Thus, in type 1 diabetes mellitus, measures of glycemic variability are useful in predicting both actual and long-lasting glycemic control. In absence of diabetes-related complications and of any intima-media thickness alterations, the major predictors of arterial distensibility are represented by traditional risk factors beside glycemic 24-h control.


Asunto(s)
Glucemia/metabolismo , Arterias Carótidas/patología , Grosor Intima-Media Carotídeo , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/patología , Adulto , Arterias Carótidas/diagnóstico por imagen , Complicaciones de la Diabetes/sangre , Complicaciones de la Diabetes/diagnóstico por imagen , Complicaciones de la Diabetes/patología , Diabetes Mellitus Tipo 1/diagnóstico por imagen , Femenino , Humanos , Masculino , Factores de Riesgo
18.
J Clin Med ; 12(9)2023 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-37176691

RESUMEN

Implantable cardiac pacemakers have greatly evolved during the few past years, focusing on newer modalities of physiologic cardiac pacing [...].

19.
J Clin Med ; 12(11)2023 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-37298059

RESUMEN

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and predisposes patients to an increased risk of cardioembolic events (CE), such as ischemic stroke, TIA, or systemic embolism [...].

20.
Minerva Cardiol Angiol ; 71(3): 342-348, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36305778

RESUMEN

BACKGROUND: Direct anchoring of PM and ICD leads over cephalic vein body is officially discouraged by manufactures due to a supposed risk of conductor fracture or insulation failure, however careful tightening of anchoring knots can probably prevent lead damage. Direct anchoring (DA) technique is routinely used in our center for all leads inserted by cephalic vein while standard anchoring sleeves are used to secure subclavian leads only. Aim of the study is to assess short- and long-term safety of cephalic direct anchoring technique. METHODS: All patients undergoing PM and ICD implantation in our center from November 2014 to March 2016 were consecutively enrolled. Primary endpoints were acute lead fracture, lead dislodgement and chronic lead failure. Secondary endpoint was a composite of short-term surgical complications (pocket hematoma, pneumothorax, and pericardial effusion) plus device infections. Subclavian leads secured with sleeve anchoring (SA) were used as control. RESULTS: A total of 550 leads were implanted in 310 consecutive patients. DA involved 323 leads (59%) while SA was used for 227 (41%). Median follow-up was 50 months (IQR 24-62 months). 17 lead malfunctions (3.1%) were observed during follow-up. No difference was observed between groups (10 DA vs. 7 SP, P=ns). Survival analysis found no difference between groups. Secondary endpoints were not statistically different between groups (5 vs. 1, P=0.08). CONCLUSIONS: Direct anchoring technique of PM and ICD leads is a safe technique and does not increase lead malfunction risk.


Asunto(s)
Marcapaso Artificial , Humanos , Marcapaso Artificial/efectos adversos , Vena Axilar , Incisión Venosa/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA