Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39259299

RESUMEN

PURPOSE: To determine the differential risk factors for retinal detachment (RD) after Boston Type 1 Keratoprosthesis (B1KPro) during the first year after surgery (early RD; ERD) and afterwards (late RD; LRD). METHODS: Retrospective cohort study of 94 eyes (90 patients) undergoing B1KPro implantation at Centro de Oftalmología Barraquer from June 2006 to July 2022 with a minimum follow-up of one year. RESULTS: The incidence of RD in the whole sample after B1KPro implantation was 29% (27/94), occurring in 21% of eyes (ERD; 20/94) the first year, and in 7% afterwards (LRD; 7/94). Hypotony was revealed as a significant risk factor for ERD (16/19 = 84%; OR = 14.5, P < 0.0001), together with aphakia (16/20 = 80%; OR = 5.9, P = 0.004), intraocular lens (IOL) removal (4/8 = 50%; OR = 6.2, P = 0.03), previous choroidal detachment (CD; 7/20 = 35%; OR = 35.5, P = 0.001) and previous pars plana vitrectomy (PPV; 15/20 = 75%; OR = 6.6, P = 0.006). Multivariate analysis included hypotony and PPV at any time as variables significantly associated with ERD occurrence. The occurrence of LRD was significantly related to peripheral retinal changes, detected few days before (4/6 = 66%; OR = 65, P < 0.0001). CONCLUSION: Hypotony emerged as one of the main factors influencing ERD occurrence after B1KPro implantation. Additionally, previous CD, PPV, aphakia, and IOL removal should be considered to estimate the risk of postoperative retinal detachment. In contrast, peripheral retinal changes after B1KPro seem to be significantly related to LRD occurrence. This study reinforces the need for frequent intraocular pressure evaluation, and comprehensive periodic retinal assessment over time. KEY MESSAGES: What is known Retinal detachment (RD) is a severe complication after Boston Type 1 Keratoprosthesis (B1KPro) implantation, resulting in a permanent reduction of visual acuity in a clinically relevant percentage of eyes. The time of RD occurrence after B1KPro implantation differs in the literature but is reported to be more common within the first year. Previous aphakia, choroidal detachment, or RD repair, intraocular lens removal, vitritis, or history of Nd-YAG laser have been described as risk factors for RD after B1KPro surgery in samples with varying follow-ups. WHAT IS NEW: Multivariate analysis in the first year after B1KPro surgery showed hypotony and pars plana vitrectomy at any time as significant risk factors for early RD. Late RD cases, occurring after one year following the B1KPro surgery, seem to be significantly related to peripheral retinal changes suffered a few days before loss of visual acuity and RD diagnosis. It is plausible to think that risk factors for RD after B1KPro differ in short and long postoperative times.

2.
Graefes Arch Clin Exp Ophthalmol ; 261(1): 161-170, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35857089

RESUMEN

PURPOSE: To analyze the anatomical and functional results of Boston type I keratoprosthesis (B1-KPro) as a primary corneal procedure in high-risk (HR) cases and non-high-risk (NHR) cases. METHODS: In this retrospective interventional case series, all patients who underwent B1-KPro at a single center between January 2006 and March 2021 were reviewed and identified. Cases were classified according to the primary diagnosis. Anatomical failure was considered in the case of prosthesis extrusion or phthisis bulbi. Functional failure was a postoperative corrected distance visual acuity (CDVA) ≥ 1.3 LogMAR (≤ 0.05 decimal) at the end of the follow-up period. RESULTS: Twenty-three eyes were included for analysis. Thirteen eyes were classified as HR and 10 as NHR. The mean age was 46.5 ± 26.5 years (5-84 years) in the HR group and 49.5 ± 26.9 years (2-78 years) in the NHR group. The mean follow-up was 42.0 ± 35.9 months (1.5-118 months) in HR and 44.8 ± 38.8 months (1-107 months) in NHR. Three eyes in the HR and none in the NHR group showed anatomical failure. Functional failure was reported in 5/13 eyes in the HR and 8/10 in the NHR group. Functional cumulative survival probability was 92% and 82% for the HR group at 1 and 2 years, respectively. In the NHR group, it was 27% at both times. No significant differences were found between groups, except for functional survival in the HR group due to better visual potential of the eyes. CONCLUSIONS: B1-KPro as a primary corneal procedure is a valid option for visual rehabilitation in high-risk cases.


Asunto(s)
Órganos Artificiales , Enfermedades de la Córnea , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Córnea/cirugía , Prótesis e Implantes , Estudios Retrospectivos , Enfermedades de la Córnea/diagnóstico , Enfermedades de la Córnea/cirugía , Implantación de Prótesis , Complicaciones Posoperatorias/cirugía , Estudios de Seguimiento
3.
BMC Ophthalmol ; 22(1): 79, 2022 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-35168601

RESUMEN

BACKGROUND: The purpose of this study is to describe measurements using a newly developed modified Goldmann convex tonometer (CT) 1 year after myopic laser refractive surgery. Intraocular pressure (IOP) measurements were compared with IOP values obtained by Goldmann applanation tonometer (GAT), and Ocular Response Analyzer (ORA). METHODS: Prospective double-masked study performed on thirty eyes of thirty patients that underwent laser in situ keratomileusis (LASIK; n = 19) or photorefractive keratectomy (PRK; n = 11). IOP was measured before and 3 and 12 months after surgery. Intraclass correlation coefficient (ICC) and Bland-Altman plot were calculated to assess the agreement between GAT, CT, IOPg (Goldmann-correlated IOP) and IOPcc (corneal-compensated IOP) from ORA. RESULTS: Twelve months after LASIK, IOP measured with CT showed the best correlation with IOP measured with GAT before surgery (GATpre) (ICC = 0.886, 95% CI: 0.703-0.956) (15.60 ± 3.27 vs 15.80 ± 3.22; p < 0.000). However, a moderate correlation was found for IOP measured with IOPcc and CT 12 months after LASIK (ICC = 0.568, 95% CI: - 0.185 - 0.843) (15.80 ± 3.22 vs 12.87 ± 2.77; p < 0.004). Twelve months after PRK, CT showed a weak correlation (ICC = - 0.266, 95% CI: - 3.896 - 0.663), compared to GATpre (17.30 ± 3.47 vs 16.01 ± 1.45; p < 0.642), as well as poor correlation (ICC = 0.256, 95% CI: - 0.332 - 0.719) with IOPcc (17.30 ± 3.47 vs 13.38 ± 1.65; p < 0.182). CONCLUSIONS: Twelve months after LASIK, IOP measured with CT strongly correlated with GAT before surgery and could therefore provide an alternative method for measuring IOP after this surgery. More studies regarding this new convex prism are needed to assess its accuracy.


Asunto(s)
Presión Intraocular , Queratomileusis por Láser In Situ , Córnea/cirugía , Humanos , Láseres de Excímeros/uso terapéutico , Polímeros , Estudios Prospectivos , Tonometría Ocular
4.
Int J Mol Sci ; 23(21)2022 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-36362082

RESUMEN

Soemmerring's rings consist of a ring of lens epithelial derived cells that grow along the periphery of an aphakic lens capsule, or around an intraocular lens. These rings when visualized frontally, appear opaque, however, in some cases the cells that compose these rings are organized in the same fashion as those in normal transparent adult lenses. Thus, our purpose was to test whether any part of the adult Soemmerring's ring could be transparent and how this related to morphological factors. To study this, 16 Soemmerring's rings were extracted from donor eye globes. After imaging, they were thickly sectioned sagittally in order to analyze the degrees of transparency of different areas. All samples were also histologically analyzed using alpha smooth muscle actin, Vimentin, wheat germ agglutinin and DAPI. Our results showed that many samples had some transparent areas, mostly towards the center of their cross-section. Of the factors that we analyzed, only lens fiber organization at the bow region and an increased area of mature lens fiber cells had a significant relation to the degree of transparency at the center. Thus, we can conclude that as Soemmerring's rings mature, they can develop organized and transparent areas of lens cells.


Asunto(s)
Cápsula del Cristalino , Cristalino , Lentes Intraoculares , Humanos , Epitelio
5.
Retina ; 40(5): 903-907, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-30845020

RESUMEN

PURPOSE: To analyze functional and anatomical results of pars plana vitrectomy (PPV) to treat endophthalmitis in eyes with osteokeratoprosthesis. METHODS: An observational, retrospective study of five eyes suffering from endophthalmitis, after an osteokeratoprosthesis implantation, which underwent PPV associated with intravitreal antibiotics. The minimum follow-up after PPV was 6 months. A descriptive study and a Kaplan-Meier survival analysis for anatomical (attached retina during the follow-up) and functional success (visual acuity ≥20/400) were performed. RESULTS: Best-corrected visual acuity during the final follow-up was 20/100 in 1 case (20%), hand movement in another case (20%), and no light perception in 3 cases (60%). The anatomical survival rates were recorded at 80%, 60%, and 40% at 1, 6, and 8 months respectively, and this last value was maintained at 12 months after PPV. The functional survival rates were recorded at 40% and 20% at 1 month and 8 months, respectively, and this last value was maintained at 12 months after PPV. CONCLUSION: Endophthalmitis in eyes with previous osteokeratoprosthesis is a very severe complication with a reserved prognosis. Pars plana vitrectomy associated with intravitreal antibiotics leads to maintaining or increasing visual acuity in a small proportion of patients who otherwise would end up blind.


Asunto(s)
Córnea/cirugía , Enfermedades de la Córnea/cirugía , Endoftalmitis/cirugía , Infecciones Bacterianas del Ojo/cirugía , Prótesis e Implantes , Agudeza Visual , Vitrectomía/métodos , Adulto , Anciano , Enfermedades de la Córnea/complicaciones , Endoftalmitis/complicaciones , Infecciones Bacterianas del Ojo/complicaciones , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
6.
Exp Eye Res ; 188: 107807, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31539543

RESUMEN

In order to study the mechanisms involved in the development of posterior capsule opacification (PCO) we compared in vivo developed PCO with PCO formed in tissue culture with focus on the periphery of the lens capsule to evaluate lens regeneration potential. We studied three human tissue groups: Cultured lens capsules after mock cataract surgery (n = 6, 30 days), lens capsules from donors that had previously undergone cataract surgery (IOL capsules) (n = 12) and intact lenses (n = 6). All samples were stained with Vimentin, alpha Smooth Muscle Actin, Picro Sirius Red (for collagen) and Paired box protein (Pax6). We found that cultured capsules and less developed IOL capsules consisted mainly of monolayers of mesenchymal cells, while more developed IOL capsules, contained lens epithelial cells (LECs), globular cells and lens fiber cells. Many IOL capsule samples expressed collagen I and III in areas where cells were in contact with the IOL. Pax6 had a similar dispersed distribution in less developed IOL capsules and cultured capsules, while more developed IOL capsules and intact lenses, concentrated Pax6 in LECs at the equatorial lens bow. The similarities between cultured capsules and less developed IOL capsules indicate that our in vitro developed PCO is comparable to early in vivo developed PCO. The similar morphology of more developed IOL capsules and intact lenses seems to indicate an attempt at lens regeneration.


Asunto(s)
Opacificación Capsular/patología , Cápsula Posterior del Cristalino/patología , Actinas/metabolismo , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/metabolismo , Opacificación Capsular/metabolismo , Extracción de Catarata , Femenino , Humanos , Técnicas para Inmunoenzimas , Implantación de Lentes Intraoculares , Masculino , Persona de Mediana Edad , Técnicas de Cultivo de Órganos , Cápsula Posterior del Cristalino/metabolismo , Donantes de Tejidos , Vimentina/metabolismo
7.
Ophthalmic Res ; 62(3): 157-165, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30921809

RESUMEN

PURPOSE: To evaluate the relationship between the presence of cortical cataract and accommodation effort, using refractive error as a proxy. METHODS: Patients between 50 and 90 years, scheduled for cataract surgery, were selected with the help of a photographic database. Nuclear and cortical cataract were graded and patients grouped having no cataract, pure cortical, mixed or pure nuclear cataract. Refraction data at the time of the photograph was converted to estimated spherical equivalent refractive error each patient would have had at the age of 45 years. RESULTS: From the initial 239 eyes from 239 patients, cases with myopia below -6.5 dpt and hyperopia above 6.5 dpt were excluded, resulting in 199 cases for final analysis. Eyes with no cataract showed the lowest median refractive error (-3.65 dpt), followed by the pure nuclear group (-2.69 dpt). The median refractive error for pure cortical (-0.23 dpt) and mixed cataracts (-0.87 dpt) were close to emmetropia. Cortical cataracts were found in 37% of myopes, 82% of emmetropes, and 85% of hyperopes. CONCLUSION: Emmetropes and hyperopes tend to develop more cortical cataract than myopes. These cortical cataracts might be caused by shear stress inside the crystalline lens due to accommodation efforts at the time of onset of presbyopia.


Asunto(s)
Catarata/fisiopatología , Refracción Ocular/fisiología , Errores de Refracción/fisiopatología , Anciano , Anciano de 80 o más Años , Catarata/complicaciones , Emetropía/fisiología , Femenino , Humanos , Hiperopía/fisiopatología , Masculino , Persona de Mediana Edad , Miopía/fisiopatología , Errores de Refracción/etiología
8.
Exp Eye Res ; 168: 19-27, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29288023

RESUMEN

Experimental protocols have been developed to measure the spatial variation of the mechanical strains induced in the lens capsule during ex vivo lens stretching. The paper describes the application of these protocols to porcine lenses. The deformations and mechanical strains developed in the anterior capsule during each experiment were determined using full field digital image correlation techniques, by means of a speckle pattern applied to the lens surface. Several speckling techniques and illumination methods were assessed before a suitable combination was found. Additional data on the cross section shape of the anterior lens surface were obtained by Scheimpflug photography, to provide a means of correcting for lens curvature effects in the determination of the strains developed in the plane of the capsule. The capsule strains in porcine lenses exhibit non-linear behaviour, and hysteresis during loading and unloading. Peripheral regions experience higher magnitude strains than regions near the lens pole. The paper demonstrates the successful application of a procedure to make direct measurements of capsule strains simultaneously with ex vivo radial lens stretching. This experimental technique is applicable to future investigations on the mechanical characteristics of human lenses.


Asunto(s)
Acomodación Ocular/fisiología , Cápsula Anterior del Cristalino/fisiología , Cápsula del Cristalino/fisiología , Animales , Longitud Axial del Ojo/fisiología , Modelos Animales , Porcinos
9.
Retina ; 38(12): 2336-2342, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28961672

RESUMEN

PURPOSE: To evaluate the anatomical and functional results of pars plana vitrectomy in eyes with osteo-keratoprosthesis, who have suffered retinal detachment. METHODS: An observational, retrospective study of 18 eyes which underwent pars plana vitrectomy for retinal detachment after an implantation of an osteo-keratoprosthesis, with a minimum of 1-year follow-up. A descriptive study and a Kaplan-Meier survival analysis for anatomical and functional success were performed. Anatomical success was defined as an attached retina at the end of vitreoretinal surgery with no redetachment during the follow-up. Functional success was defined as a postoperative visual acuity of more than or equal to 20/400. RESULTS: The overall rate of anatomical success was 56%, and the anatomical survival rates were 67% and 53% at 6 months and 12 months, respectively, maintaining this last value at 24 months after pars plana vitrectomy. The overall rate of functional success was 17%, and the functional survival rates were 83%, 39%, and 14% at 6 months, 12 months, and 24 months after pars plana vitrectomy, respectively. The most frequent complication after retinal surgery was retroprosthetic membrane (33%). CONCLUSION: Despite the reserved prognosis and the severe complications, vitrectomy represents a valid method for treating retinal detachment in patients with osteo-keratoprosthesis, with good anatomical results but poor visual acuity.


Asunto(s)
Órganos Artificiales , Córnea/cirugía , Enfermedades de la Córnea/cirugía , Desprendimiento de Retina/cirugía , Agudeza Visual , Vitrectomía/métodos , Adulto , Anciano , Enfermedades de la Córnea/complicaciones , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Retina/patología , Desprendimiento de Retina/complicaciones , Desprendimiento de Retina/diagnóstico , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
10.
Ophthalmic Res ; 57(4): 247-251, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28288454

RESUMEN

PURPOSE: To evaluate a new nuclear cataract grading system which is intended as a surgical guidance system to predict lens hardness before cataract surgery. METHODS: The new BCN 10 grading system consists of frontal and cross-sectional slit-lamp images of human eye lenses, ranging from a completely transparent lens nucleus to a totally black nuclear cataract. Validation was done with 9 observers for 110 cases. Two modalities were applied, and observers were asked to use only whole digits and then half digits for grading. RESULTS: Repeatability with regard to test-retest differences showed a mean limit of agreement of 1.70 for whole digits and 1.32 for half digits. The absolute test-retest difference was close to zero for low as well high degrees of cataracts. Reliability for the entire group of 9 observers yielded an intraclass correlation coefficient which was within the same confidence interval, i.e., 0.991-0.995, for whole digits and half digits. CONCLUSIONS: BCN 10 grading repeatability was not affected by the severity of the cataract. It showed very good repeatability. Repeatability was significantly higher when the observers used half digits compared to whole digits. Reliability was found to be very good as well, independently of the use of whole or half digits.


Asunto(s)
Envejecimiento , Catarata/congénito , Núcleo del Cristalino/diagnóstico por imagen , Anciano , Catarata/clasificación , Catarata/diagnóstico , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
11.
Exp Eye Res ; 145: 100-109, 2016 04.
Artículo en Inglés | MEDLINE | ID: mdl-26611157

RESUMEN

A combination of Raman spectroscopy, imaging, hierarchical cluster analysis (HCA) and peak ratio analysis was used to analyze protein profiles in the superficial cortex (SC), deep cortex (DC) and nucleus of old human lenses with cortical, nuclear and mixed cataracts. No consistent differences were observed in protein spectra and after cluster analysis between the three locations irrespective of the presence or absence of cortical opacities and/or coloration. A sharp increase (∼15%-∼33%) in protein content from SC to DC, normal for human lenses, was found in 7 lenses. In 4 lenses, characterized by the absence of cortical opacities, the SC has a protein content of ∼35%. A significant increase in the disulfide-to-protein ratio is found only in the SC of the 7 cortical cataracts. No changes were found in sulfhydryl-to-protein ratio. The relative contents of α-helices and ß-sheets increase from SC to nucleus. ß-Sheets are more common in the SC of lenses with cortical cataract. The absence of significant and consistent changes in protein profiles between nucleus and cortex even in cases of severe coloration is not favoring the prevailing concept that ubiquitous protein oxidation is a key factor for age related nuclear (ARN) cataracts. The observations favor the idea that multilamellar bodies or protein aggregates at very low volume densities are responsible for the rise in Mie light scatter as a main cause of ARN cataracts leaving the short-range-order of the fiber cytoplasm largely intact. The absence of significant changes in the protein spectra of the deep cortical opacities, milky white as a result of the presence of vesicle-like features, indicate they are packed with relatively undisturbed crystallins.


Asunto(s)
Catarata/metabolismo , Cristalinas/metabolismo , Corteza del Cristalino/metabolismo , Núcleo del Cristalino/metabolismo , Donantes de Tejidos , Anciano , Anciano de 80 o más Años , Catarata/diagnóstico , Femenino , Humanos , Masculino , Espectrometría Raman
12.
Ophthalmic Res ; 56(4): 202-206, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27160090

RESUMEN

PURPOSE: To evaluate the corneal button of primary penetrating keratoplasty of patients diagnosed with congenital aniridia. The study took place at the Instituto Universitario Barraquer and the Centro de Oftalmología Barraquer. METHODS: A retrospective analysis of cases diagnosed with congenital aniridia was carried out. We analyzed 13 corneal buttons of 11 eyes with congenital aniridia. We only included those patients who underwent penetrating keratoplasty for the first time. The corneal buttons were analyzed for histological characteristics of the presence of vascularization, the presence or not of Bowman's layer, the thickness of the stroma and Descemet's membrane, and endothelium layer alterations. RESULTS: We found alterations in the epithelium and stroma in all patients, although this loss of architecture was not seen in Descemet's membrane and the endothelial population. CONCLUSION: Patients with advanced congenital aniridic keratopathy may be good candidates for deep or superficial anterior lamellar keratoplasty for the preservation of normal endothelium and Descemet's membrane, along with limbal stem cell transplantation, to address epithelial and stromal pathology.


Asunto(s)
Aniridia/patología , Córnea/patología , Queratoplastia Penetrante , Adulto , Aniridia/cirugía , Recuento de Células , Córnea/cirugía , Lámina Limitante Posterior/patología , Endotelio Corneal/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Agudeza Visual , Adulto Joven
13.
J Refract Surg ; 31(1): 30-5, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25486676

RESUMEN

PURPOSE: To describe the main causes of explantation of phakic intraocular lenses (PIOLs) according to the anatomical site of implantation (angle supported, iris fixated, or posterior chamber). METHODS: This multicentric, retrospective, and consecutive study sponsored by the Spanish Ministry of Health comprised a total of 240 eyes (226 patients) explanted due to PIOL complications. Clinical data of 144 angle-supported lenses, 24 iris-fixated lenses, and 72 posterior chamber lenses explanted were recorded preoperatively and postoperatively. RESULTS: Mean age of the patients at explantation was 46.30 ± 11.84 years (range: 25 to 80 years). The mean time between implantation and explantation was 381.14 ± 293.55 weeks (range: 0.00 to 1,551.17 weeks). It was 422.33 ± 287.81 weeks for the angle-supported group, 488.03 ± 351.95 weeks for the iris-fixated group, and 234.11 ± 4,221.60 weeks for the posterior chamber group. It was 8.10 ± 5.52 years for the angle-supported group, 9.36 ± 6.75 years for the iris-fixated group, and 4.49 ± 4.25 years for the posterior chamber group. This period of time was significantly shorter in the posterior chamber group (P < .001). Overall, the main causes of explantation were cataract formation (132 eyes, 55%), endothelial cell loss (26 eyes, 10.83%), corneal decompensation (22 eyes, 9.17%), PIOL dislocation/decentration (16 eyes, 6.67%), inadequate PIOL size or power (12 eyes, 5%), and pupil ovalization (10 cases, 4.17%). Cataract development was the cause of explantation in 51.39% of angle-supported cases, 45.83% of iris-fixated cases, and 65.28% of posterior chamber cases. Endothelial cell loss was the cause of explantation in 15.97% of angle-supported PIOLs, 8.33% of iris-fixated PIOLs, and 1.39% of posterior chamber PIOLs. CONCLUSIONS: Cataract is the main cause of PIOL explantation, especially in posterior chamber PIOLs. In the angle-supported group, endothelial cell loss was the second cause of explantation.


Asunto(s)
Catarata/complicaciones , Implantación de Lentes Intraoculares/efectos adversos , Miopía/cirugía , Lentes Intraoculares Fáquicas/efectos adversos , Complicaciones Posoperatorias/etiología , Errores de Refracción , Adulto , Anciano , Anciano de 80 o más Años , Catarata/patología , Glaucoma/complicaciones , Humanos , Persona de Mediana Edad , Miopía/complicaciones , Desprendimiento de Retina/complicaciones , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
14.
Exp Eye Res ; 119: 44-53, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24333259

RESUMEN

We have compared the protein profiles in plaques and tangles in the hippocampus of post-mortem Alzheimer brains and in opaque and clear regions in the deep cortex of eye lenses of the same donors. From the 7 Alzheimer donors studied, 1 had pronounced bilateral cortical lens opacities, 1 moderate and 5 only minor or no cortical opacities. We focused on beta-sheet levels, a hallmarking property of amyloid-beta, the major protein of plaques and tau protein, the major protein of tangles in Alzheimer brains. Confocal Raman microspectroscopy and imaging was used in combination with hierarchical cluster analysis. Plaques and tangles show high levels of beta-sheets with a beta-sheet to protein ratio of 1.67. This ratio is 1.12 in unaffected brain tissue surrounding the plaques and tangles. In the lenses this ratio is 1.17 independently of the presence or absence of opacities. This major difference in beta-sheet conformation between hippocampus and lens is supported by Congo red and immunostaining of amyloid-beta and tau which were positive for plaques and tangles in the hippocampus but fully negative for the lens irrespective of the presence or absence of opacities. In line with a previous study (Michael et al., 2013) we conclude that cortical lens opacities are not typical for Alzheimer patients and are not hallmarked by accumulation of amyloid-beta, and can thus not be considered as predictors or indicators of Alzheimer disease as claimed by Goldstein et al. (2003).


Asunto(s)
Enfermedad de Alzheimer/metabolismo , Péptidos beta-Amiloides/análisis , Catarata/metabolismo , Cristalino/química , Placa Amiloide/química , Espectrometría Raman/métodos , Anciano , Anciano de 80 o más Años , Enfermedad de Alzheimer/complicaciones , Enfermedad de Alzheimer/patología , Catarata/complicaciones , Catarata/patología , Femenino , Hipocampo/química , Hipocampo/patología , Humanos , Inmunohistoquímica , Masculino , Persona de Mediana Edad
15.
Graefes Arch Clin Exp Ophthalmol ; 252(1): 83-90, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24390466

RESUMEN

PURPOSE: To describe the outcome of patients with Boston type 1 keratoprosthesis, with regard to anatomical and visual success. METHODS: Retrospective case series of patients who underwent Boston type I keratoprosthesis surgery at the Centro de Oftalmología Barraquer in Barcelona and at the University Eye Clinic in Salzburg between May 2006 and December 2011. Sixty-seven eyes were included. Anatomical success, visual acuity, and complication rate were evaluated and correlated with the initial diagnosis. RESULTS: The mean age of patients was 54 years; 62 % were male and 38 % were female. Eleven patients underwent Type I Boston Kpro implantation as a primary procedure, while the other 52 patients had previous graft failure. The most frequent diagnoses were autoimmune diseases (16 eyes), severe chemical or thermal burn (12 eyes), leukoma post-infectious keratitis (seven eyes) and bullous keratopathy (six eyes). The mean follow-up time was 26 months. Retention of the prosthesis was achieved in 95 % at 1 year and 78 % at 4.5 years. Two eyes suffered extrusion of the KPro, six underwent successful exchange of the prosthesis either due to infection, necrosis or extrusion, three KPro's had to be explantated, and two eyes ended up in enucleation due to panophthalmitis. The outcome of the autoimmune cases was similar to the group with "other diagnoses" and better than those with chemical/thermal burn. The most frequent complication was development of a retroprosthetic membrane in 21 eyes (34 %). Visual acuity (LogMAR) in the chemical/thermal burn group was 2.30 preoperatively, 0.69 at 1 year, 0.52 at 2 years and 0.39 at 3 years; in the autoimmune group visual acuity was 2.3 preoperatively, 0.65 at 1 year, 0.15 at 2 years, and 1.5 at 3 years. CONCLUSIONS: Boston type 1 keratoprosthesis is a viable option for patients with repeated graft failure, even for those with challenging diagnoses such as ocular burns and autoimmune syndromes.


Asunto(s)
Bioprótesis , Córnea , Enfermedades de la Córnea/cirugía , Supervivencia de Injerto/fisiología , Implantación de Prótesis , Agudeza Visual/fisiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Pronóstico , Estudios Retrospectivos , Adulto Joven
16.
Ophthalmic Res ; 52(1): 9-16, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24853485

RESUMEN

PURPOSE: To analyse how primary diagnosis and complications affect the evolution of post-operative visual acuity (VA). METHODS: We performed retrospective chart analysis on 59 eyes in 57 patients with various diagnoses, most of which were non-standard indications for Boston type 1 keratoprosthesis (Kpro) implantation. The follow-up period was at least 3 months. Patients were classified based on the evolution of post-operative VA: group A demonstrated stable VA improvement, group B lost VA improvement and group C no significant VA improvement. RESULTS: We assigned 46% of our cases to group A with stable VA improvement, 32% to group B with lost VA improvement, and 22% to group C with no VA improvement. The number of graft failures before Kpro implantation did not influence VA outcome. Except for the relatively good VA outcome in chemical burn and radiation injury patients, there seems to be no association between primary diagnosis and positive or negative VA outcome. Only 9% of patients with posterior segment complications and 20% with infections and associated pathologies were assigned to group A. CONCLUSION: Most cases (78%) showed improvement in VA after Boston type 1 Kpro (groups A and B). Posterior segment complications and infections mostly resulted in persistent loss of vision. These complications should be prevented and carefully treated.


Asunto(s)
Órganos Bioartificiales , Córnea , Enfermedades de la Córnea/diagnóstico , Enfermedades de la Córnea/cirugía , Complicaciones Posoperatorias , Agudeza Visual/fisiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Enfermedades de la Córnea/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Adulto Joven
17.
Eur J Ophthalmol ; 34(2): 432-439, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37461240

RESUMEN

PURPOSE: To report the causes of pseudophakic intraocular lens (IOL) explantation in Spain over a 20 year period. METHODS: Multicenter observational prospective study of a consecutive series of cases corresponding to pseudophakic intraocular lenses explantations performed in 22 Spanish clinical centres from 2002 to 2021, within a national clinical research network. The clinical data of all IOL explantation patients was evaluated, and the different causes for IOL explantation were systematically analyzed. RESULTS: From a total of 1013 pseudophakic explantations, 919 cases were included in this investigation. The mean age of the patients at the time of explantation was 66.3 years, and 142 (15.45%) were women. Over the 20 years of the study, the five main reasons for explanting lenses in the last 20 years in Spain according to the Iberia RETICS database were: dislocation / decentration / misalignment (43.08%), bullous keratopathy (16.79%), neuroadaptation failure (13.85%), IOL opacification (9.71%), refractive surprise (6.87%). Other causes, less frequent, were uveitis / endophthalmitis / infection with 39 cases (4.25%); IOL substitution for reasons other than multifocal IOL neuroadaptation failure 3 cases (0.33%); and other causes, 47 cases (5.13%). Hydrophobic lenses were the most frequently explanted with a ratio of 47.1%. CONCLUSIONS: Over the 20 years of the study, the five main reasons for explanting lenses in the last 20 years in Spain according to the Iberia RETICS database were: dislocation / decentration / misalignment, bullous keratopathy, neuroadaptation failure, IOL opacification, and refractive surprise.


Asunto(s)
Lentes Intraoculares , Humanos , Femenino , Anciano , Masculino , España/epidemiología , Estudios Prospectivos , Lentes Intraoculares/efectos adversos , Complicaciones Posoperatorias/etiología , Agudeza Visual
18.
Transl Vis Sci Technol ; 13(5): 11, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38748408

RESUMEN

Purpose: Computational models can help clinicians plan surgeries by accounting for factors such as mechanical imbalances or testing different surgical techniques beforehand. Different levels of modeling complexity are found in the literature, and it is still not clear what aspects should be included to obtain accurate results in finite-element (FE) corneal models. This work presents a methodology to narrow down minimal requirements of modeling features to report clinical data for a refractive intervention such as PRK. Methods: A pipeline to create FE models of a refractive surgery is presented: It tests different geometries, boundary conditions, loading, and mesh size on the optomechanical simulation output. The mechanical model for the corneal tissue accounts for the collagen fiber distribution in human corneas. Both mechanical and optical outcome are analyzed for the different models. Finally, the methodology is applied to five patient-specific models to ensure accuracy. Results: To simulate the postsurgical corneal optomechanics, our results suggest that the most precise outcome is obtained with patient-specific models with a 100 µm mesh size, sliding boundary condition at the limbus, and intraocular pressure enforced as a distributed load. Conclusions: A methodology for laser surgery simulation has been developed that is able to reproduce the optical target of the laser intervention while also analyzing the mechanical outcome. Translational Relevance: The lack of standardization in modeling refractive interventions leads to different simulation strategies, making difficult to compare them against other publications. This work establishes the standardization guidelines to be followed when performing optomechanical simulations of refractive interventions.


Asunto(s)
Simulación por Computador , Córnea , Análisis de Elementos Finitos , Queratectomía Fotorrefractiva , Humanos , Córnea/cirugía , Córnea/fisiología , Queratectomía Fotorrefractiva/métodos , Simulación por Computador/normas , Láseres de Excímeros/uso terapéutico , Modelos Biológicos
19.
Cornea ; 43(8): 1058-1061, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38692691

RESUMEN

PURPOSE: The aim of this study was to describe the clinical features and endothelial involvement in a case of Mpox virus keratitis by in vivo confocal microscopy (IVCM). METHODS: This is a case report. RESULTS: A 35-year-old man presented with redness, photophobia, pain, tearing, and a low visual acuity of 0.09 (decimal) in the left eye with a 6-week history of Mpox and corneal trauma. Previous testing of blood, interdigital skin lesions, and conjunctival and eyelid margin swabs confirmed the presence of Mpox by polymerase chain reaction. Biomicroscopy displayed superficial stromal infiltrates with a continuous but irregular epithelium. IVCM revealed the presence of pseudoguttata, loss of defined cell boundaries, infiltration of inflammatory cells in the endothelial layer, endothelial ridges, and precipitated pigmented granules, consistent with endotheliitis. After this episode, the patient had 4 reactivations, also treated with topical corticoids and oral tecovirimat 600 mg twice a day for 2 weeks. On the fourth reactivation, this treatment was extended to 4 weeks. On the last visit, the patient presented a visual acuity of 0.5 with disciform keratitis and reduced endotheliitis signs. The endothelial cell density remained normal during the follow-up (2763 ± 376 cell/mm 2 at baseline and 2795 ± 238 cell/mm 2 at the last visit). Polymegathism and pleomorphism showed altered values during the follow-up. CONCLUSIONS: Patients with an altered corneal epithelial barrier could suffer Mpox endotheliitis, like other DNA viruses, before disciform keratitis appears. IVCM is a useful tool for the early detection of endotheliitis and for describing its evolution, improving patient care.


Asunto(s)
Endotelio Corneal , Infecciones Virales del Ojo , Microscopía Confocal , Humanos , Masculino , Adulto , Infecciones Virales del Ojo/virología , Infecciones Virales del Ojo/diagnóstico , Infecciones Virales del Ojo/tratamiento farmacológico , Endotelio Corneal/patología , Queratitis/diagnóstico , Queratitis/tratamiento farmacológico , Queratitis/virología , Agudeza Visual/fisiología , ADN Viral/análisis
20.
J Clin Med ; 13(12)2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38929940

RESUMEN

Background: To assess intraocular pressure (IOP) changes and complications after XEN45 implants in medically controlled eyes (MCE) vs. medically uncontrolled eyes (MUE). Methods: A retrospective study, in a tertiary referral hospital, on mild-to-moderate primary open-angle glaucoma (POAG) cases under topical medication, including 32 eyes with IOP < 21 mmHg (MCE group) and 30 eyes with IOP ≥ 21 mmHg (MUE group). The success criteria using Kaplan-Meier analysis was IOP < 21 mmHg without medications (complete success) or fewer drugs than preoperatively (qualified success) at the last visit, without new surgery or unresolved hypotony. Results: No significant preoperative differences were found between the groups. The mean IOP was 15.6 ± 3.8 mmHg in MCE and 15.1 ± 4.1 mmHg in the MUE group (p > 0.05; Mann-Whitney test) at the end of the follow-up (mean of 26.1 ± 15.6 months and 28.3 ± 15.3 months, respectively) (p = 0.414, Mann-Whitney Test). The device caused a significant IOP reduction at 24 h in both groups. Thereafter, the MCE group significantly tended to increase IOP, recovering baseline values at 1 month and maintaining them until the end of the follow-up. In contrast, in the MUE group, the IOP values tended to be similar after the first reduction. No relevant complications and no significant differences between the groups in the survival analysis were found. Conclusions: XEN45 provided stable IOP control in both the MCE and MUE group without important complications in the medium term. The IOP increasing in the MCE group, after a prior decrease, led to restored baseline values 1 month after surgery. The homeostatic mechanism that causes the rise in the IOP to baseline values and its relationship with failure cases remains to be clarified.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA