Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Clin Med ; 11(8)2022 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-35456246

RESUMEN

The purpose of this study was to calculate and compare individual cardiovascular risk (CVR) and the development of cardiovascular events and mortality in patients with and without ocular pseudoexfoliation (PEX). A cohort study was carried out to compare two groups of patients who underwent cataract surgery: patients with (n = 99) and without PEX (n = 239). The CVR factors were recorded for all the subjects, and CVR was calculated for each individual using ERICE risk assessment charts. After a six-year follow-up, the cardiovascular events and mortality rates were compared between the two groups. The mean CVR was 36.41% in the PEX group and 33.72% in the non-PEX group (p = 0.13). High blood pressure was detected in significantly more PEX patients (71.4%) than non-PEX patients (58.6%, p = 0.035), yet no differences were found in the other CVR factors. The prevalence of cardiovascular events in the PEX and non-PEX patients was 17.1% and 12.5%, respectively (p = 0.26), with 5% of patients in the PEX group and 5% in the non-PEX group suffering an acute coronary event (p = 0.9). Moreover, 12% of the PEX patients and 7.5% of the non-PEX patients experienced a stroke (p = 0.17), and the six-year mortality rate was 29.3% in the PEX group and 25.9% in the non-PEX group (p = 0.52). PEX was associated with high blood pressure in our cohort of patients, although cardiovascular risk was not shown to be higher in this group. In addition, patients with PEX did not experience more cardiovascular events or have a higher mortality rate than patients without PEX during the period studied.

2.
Acta Ophthalmol ; 99(7): e973-e983, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33433050

RESUMEN

In the context of the COVID-19 pandemic, this paper provides recommendations for medical eye care during the easing of control measures after lockdown. The guidelines presented are based on a literature review and consensus among all Spanish Ophthalmology Societies regarding protection measures recommended for the ophthalmologic care of patients with or without confirmed COVID-19 in outpatient, inpatient, emergency and surgery settings. We recommend that all measures be adapted to the circumstances and availability of personal protective equipment at each centre and also highlight the need to periodically update recommendations as we may need to readopt more restrictive measures depending on the local epidemiology of the virus. These guidelines are designed to avoid the transmission of SARS-CoV-2 among both patients and healthcare staff as we gradually return to normal medical practice, to prevent postoperative complications and try to reduce possible deficiencies in the diagnosis, treatment and follow-up of the ophthalmic diseases. With this update (5th ) the Spanish Society of Ophthalmology is placed as one of the major ophthalmology societies providing periodic and systematized recommendations for ophthalmic care during the COVID-19 pandemic.


Asunto(s)
COVID-19/transmisión , Control de Enfermedades Transmisibles/métodos , Oftalmología/normas , Equipo de Protección Personal/normas , COVID-19/epidemiología , Consenso , Oftalmopatías/terapia , Humanos , Pandemias/prevención & control , Guías de Práctica Clínica como Asunto , SARS-CoV-2 , España , Telemedicina/métodos
3.
Endocrinol Nutr ; 55(7): 308-10, 2008 Aug.
Artículo en Inglés, Español | MEDLINE | ID: mdl-22975525

RESUMEN

Non-ketotic hyperglycemia has occasionally been associated with various neurological abnormalities including movement disorders. Hyperglycemic hyperosmolar syndrome (HHS) is the second most common cause of hemiballism-hemichorea, which is due to a contralateral putaminal lesion. We describe a 95-year-old woman with HHS who developed hemichorea-hemiballism syndrome due to a putaminal lesion.

4.
J Clin Anesth ; 42: 26-30, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28803124

RESUMEN

STUDY OBJECTIVE: To evaluate the influence of neuromuscular blockade (NMB) on surgical conditions during low-pressure pneumoperitoneum (8mmHg) laparoscopic cholecystectomy (LC), while comparing moderate and deep NMB. Secondary objective was to evaluate if surgical conditions during low-pressure pneumoperitoneum LC performed with deep NMB could be comparable to those provided during standard-pressure pneumoperitoneum (12mmHg) LC. DESIGN: Prospective, randomized, blinded clinical trial. SETTING: Operating room. PATIENTS: Ninety ASA 1-2 patients scheduled for elective LC. INTERVENTIONS: Patients were allocated into 3 groups: Group 1: low-pressure pneumoperitoneum with moderate-NMB (1-3 TOF), Group 2: low-pressure pneumoperitoneum with deep-NMB (1-5 PTC) and Group 3: standard pneumoperitoneum (12mmHg). Rocuronium was used to induce NMB and acceleromiography was used for NMB monitoring (TOF-Watch-SX). MEASUREMENTS: Three experienced surgeons evaluated surgical conditions using a four-step scale at three time-points: surgical field exposure, dissection of the gallbladder and extraction/closure. MAIN RESULTS: Low-pressure pneumoperitoneum (Group 1 vs. 2): good conditions: 96.7 vs. 96.7%, 90 vs. 80% and 89.6 vs. 92.3%, respectively for the time-points, p>0.05. No differences in optimal surgical conditions were observed between the groups. Surgery completion at 8mmHg pneumoperitoneum: 96.7 vs. 86.7%, p=0.353. Standard-pressure pneumoperitoneum vs. low-pressure pneumoperitoneum with deep NMB (Group 3 vs. 2): good conditions: 100% in Group 3 for the three time-points (p=0.024 vs. Group 2 at dissection of the gallbladder). Significantly greater percentage of optimal conditions during standard-pressure pneumoperitoneum LC at the three time points of evaluation. CONCLUSIONS: The depth of NMB was found not to be decisive neither in the improvement of surgical conditions nor in the completion of low-pressure pneumoperitoneum LC performed by experienced surgeons. Surgical conditions were considered better with a standard-pressure pneumoperitoneum, regardless of the depth of NMB, than during low-pressure pneumoperitoneum with deep NMB.


Asunto(s)
Colecistectomía Laparoscópica/efectos adversos , Bloqueo Neuromuscular/efectos adversos , Fármacos Neuromusculares no Despolarizantes/efectos adversos , Neumoperitoneo Artificial/efectos adversos , Adulto , Androstanoles/efectos adversos , Colecistectomía Laparoscópica/métodos , Procedimientos Quirúrgicos Electivos , Femenino , Vesícula Biliar/cirugía , Humanos , Masculino , Persona de Mediana Edad , Bloqueo Neuromuscular/métodos , Neumoperitoneo Artificial/métodos , Estudios Prospectivos , Rocuronio , Resultado del Tratamiento
5.
J Clin Anesth ; 34: 197-203, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27687373

RESUMEN

STUDY OBJECTIVE: To evaluate the effect of neuromuscular blockade (NMB) upon the abdominal space during pneumoperitoneum establishment in laparoscopic surgery, comparing moderate NMB and deep NMB. DESIGN: Prospective, randomized, crossover clinical trial. SETTING: Operating room. PATIENTS: Seventy-six American Society of Anesthesiologists 1 to 2 patients scheduled for elective laparoscopic surgery. INTERVENTIONS: Two independent evaluations were performed at the establishment of pneumoperitoneum for a preset intraabdominal pressures (IAPs) of 8 and 12 mm Hg, both during moderate NMB (train-of-four count, 1-3) and deep NMB (posttetanic count, <5). Rocuronium was used to induce NMB, and sugammadex was used for reversal. MEASUREMENTS: We evaluated (i) the volume of CO2 introduced in 41 patients and (ii) the skin-sacral promontory distance in 35 patients, at pneumoperitoneum establishment. RESULTS: Compared to moderate NMB, deep NMB increased, in a significant manner, both the intraabdominal volume of CO2 insufflated (mean [SD], 2.24 [1.10] vs 2.81 [1.13] L at 8 mm Hg IAP, P<.001, and 3.52 [1.31] vs 4.09 [1.31] L at 12 mm Hg IAP, P<.001) and the skin-sacral promontory distance (11.78 [1.52] vs 12.16 [1.51] cm at 8 mm Hg IAP, P=.002, and 13.34 [1.87] vs 13.80 [1.81] cm at 12 mm Hg IAP, P<.001). Increase in intraabdominal volume after inducing deep NMB was observed in 88% and 81.7% of patients at 8 and 12 mm Hg pneumoperitoneum, with a volume increase of mean of 36.8% (95% confidence interval [CI], 22.8-50.8) and 25% (95% CI, 13.7-36.4), respectively (P=.003). Increase in distance was observed in 61% and 82% of patients at 8 and 12 mm Hg pneumoperitoneum, with a mean distance increase of 3.3% (95% CI, 1.3-5.4) and 3.6% (95% CI, 1.9-5.2), respectively (P=.840). CONCLUSIONS: Deep NMB, in comparison to moderate NMB, increased in a significant manner the abdominal space at pneumoperitoneum establishment. However, the effective increase in the abdominal cavity dimensions could be low, the increase showed a great interindividual variability, and it was not observed in every patient. Clinical significance of this increase on surgical conditions is yet to be demonstrated.


Asunto(s)
Androstanoles/administración & dosificación , Laparoscopía , Bloqueo Neuromuscular/métodos , Fármacos Neuromusculares no Despolarizantes/administración & dosificación , Neumoperitoneo Artificial , Cavidad Abdominal , Adulto , Androstanoles/efectos adversos , Colecistectomía Laparoscópica , Estudios Cruzados , Procedimientos Quirúrgicos Electivos , Femenino , Procedimientos Quirúrgicos Ginecológicos , Humanos , Inyecciones Intraperitoneales , Insuflación , Masculino , Persona de Mediana Edad , Bloqueo Neuromuscular/efectos adversos , Fármacos Neuromusculares no Despolarizantes/efectos adversos , Estudios Prospectivos , Rocuronio , Sugammadex , gamma-Ciclodextrinas/administración & dosificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA