Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Vasc Interv Radiol ; 32(2): 220-225.e2, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33461874

RESUMEN

PURPOSE: To evaluate the impact of a versatile flexible ceiling-mounted C-arm on active table and gantry repositioning during interventions and its effect on operator discomfort, system usability, and patient safety compared with a traditional ceiling-mounted system. MATERIALS AND METHODS: There were 100 IR procedures studied: 50 in a traditional IR system (standard group) and 50 with a novel multiaxis ceiling-mounted system (test group). FlexArm was capable of multiple gantry rotation points allowing increased access to the patient in addition to 236 cm of lateral x-ray detector travel. For each procedure, both the table and the gantry repositioning were measured. Patient safety, patient/equipment repositioning effort, and physical discomfort were evaluated through an operator survey. RESULTS: Table repositioning was reduced from 42 to 16 instances per procedure (P < .001) in the test group compared with the standard group. The operators perceived less table and gantry repositioning effort (P < .0001) and decreased risks of equipment collisions, displacement of vascular access, and dislodgment of tubes/lines with the test group (P < .0001). Operator discomfort was reduced for all body areas in the test group over the standard group (P < .0001). CONCLUSIONS: The FlexArm system geometry enhances operator ergonomics, as there was a decrease need to move the table, leading to a perceived decrease in patient risk and decrease operator physical discomfort when compared to a traditional imaging system.


Asunto(s)
Angiografía/instrumentación , Ergonomía , Radiografía Intervencional/instrumentación , Radiólogos , Angiografía/efectos adversos , Diseño de Equipo , Humanos , Enfermedades Musculoesqueléticas/etiología , Enfermedades Musculoesqueléticas/prevención & control , Enfermedades Profesionales/etiología , Enfermedades Profesionales/prevención & control , Salud Laboral , Posicionamiento del Paciente , Seguridad del Paciente , Estudios Prospectivos , Radiografía Intervencional/efectos adversos , Flujo de Trabajo
2.
Vasc Med ; 26(5): 515-525, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34009060

RESUMEN

Diagnostic criteria to classify severity of internal carotid artery (ICA) stenosis vary across vascular laboratories. Consensus-based criteria, proposed by the Society of Radiologists in Ultrasound in 2003 (SRUCC), have been broadly implemented but have not been adequately validated. We conducted a multicentered, retrospective correlative imaging study of duplex ultrasound versus catheter angiography for evaluation of severity of ICA stenosis. Velocity data were abstracted from bilateral duplex studies performed between 1/1/2009 and 12/31/2015 and studies were interpreted using SRUCC. Percentage ICA stenosis was determined using North American Symptomatic Carotid Endarterectomy Trial (NASCET) methodology. Receiver operating characteristic analysis evaluated the performance of SRUCC parameters compared with angiography. Of 448 ICA sides (from 224 patients), 299 ICA sides (from 167 patients) were included. Agreement between duplex ultrasound and angiography was moderate (κ = 0.42), with overestimation of degree of stenosis for both moderate (50-69%) and severe (⩾ 70%) ICA lesions. The primary SRUCC parameter for ⩾ 50% ICA stenosis of peak-systolic velocity (PSV) of ⩾ 125 cm/sec did not meet prespecified thresholds for adequate sensitivity, specificity, and accuracy (sensitivity 97.8%, specificity 64.2%, accuracy 74.5%). Test performance was improved by raising the PSV threshold to ⩾ 180 cm/sec (sensitivity 93.3%, specificity 81.6%, accuracy 85.2%) or by adding the additional parameter of ICA/common carotid artery (CCA) PSV ratio ⩾ 2.0 (sensitivity 94.3%, specificity 84.3%, accuracy 87.4%). For ⩾ 70% ICA stenosis, analysis was limited by a low number of cases with angiographically severe disease. Interpretation of carotid duplex examinations using SRUCC resulted in significant overestimation of severity of ICA stenosis when compared with angiography; raising the PSV threshold for ⩾ 50% ICA stenosis to ⩾ 180 cm/sec as a single parameter or requiring the ICA/CCA PSV ratio ⩾ 2.0 in addition to PSV of ⩾ 125 cm/sec for laboratories using the SRUCC is recommended to improve the accuracy of carotid duplex examinations.


Asunto(s)
Arteria Carótida Interna , Estenosis Carotídea , Acreditación , Velocidad del Flujo Sanguíneo , Arteria Carótida Interna/diagnóstico por imagen , Estenosis Carotídea/diagnóstico por imagen , Constricción Patológica , Humanos , Valor Predictivo de las Pruebas , Curva ROC , Estudios Retrospectivos , Sensibilidad y Especificidad , Ultrasonografía Doppler Dúplex
3.
N Engl J Med ; 373(2): 145-53, 2015 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-26106946

RESUMEN

BACKGROUND: The treatment of peripheral artery disease with percutaneous transluminal angioplasty is limited by the occurrence of vessel recoil and restenosis. Drug-coated angioplasty balloons deliver antiproliferative agents directly to the artery, potentially improving vessel patency by reducing restenosis. METHODS: In this single-blind, randomized trial conducted at 54 sites, we assigned, in a 2:1 ratio, 476 patients with symptomatic intermittent claudication or ischemic pain while at rest and angiographically significant atherosclerotic lesions to angioplasty with a paclitaxel-coated balloon or to standard angioplasty. The primary efficacy end point was primary patency of the target lesion at 12 months (defined as freedom from binary restenosis or from the need for target-lesion revascularization). The primary safety end point was a composite of freedom from perioperative death from any cause and freedom at 12 months from limb-related death (i.e., death from a medical complication related to a limb), amputation, and reintervention. RESULTS: The two groups were well matched at baseline; 42.9% of the patients had diabetes, and 34.7% were current smokers. At 12 months, the rate of primary patency among patients who had undergone angioplasty with the drug-coated balloon was superior to that among patients who had undergone conventional angioplasty (65.2% vs. 52.6%, P=0.02). The proportion of patients free from primary safety events was 83.9% with the drug-coated balloon and 79.0% with standard angioplasty (P=0.005 for noninferiority). There were no significant between-group differences in functional outcomes or in the rates of death, amputation, thrombosis, or reintervention. CONCLUSIONS: Among patients with symptomatic femoropopliteal peripheral artery disease, percutaneous transluminal angioplasty with a paclitaxel-coated balloon resulted in a rate of primary patency at 12 months that was higher than the rate with angioplasty with a standard balloon. The drug-coated balloon was noninferior to the standard balloon with respect to safety. (Funded by Lutonix-Bard; LEVANT 2 ClinicalTrials.gov number, NCT01412541.).


Asunto(s)
Angioplastia de Balón/instrumentación , Arteria Femoral , Paclitaxel/administración & dosificación , Enfermedad Arterial Periférica/terapia , Arteria Poplítea , Anciano , Angioplastia de Balón/efectos adversos , Complicaciones de la Diabetes/terapia , Femenino , Arteria Femoral/diagnóstico por imagen , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/mortalidad , Arteria Poplítea/diagnóstico por imagen , Radiografía , Método Simple Ciego , Fumar , Grado de Desobstrucción Vascular
4.
J Vasc Interv Radiol ; 29(1): 92-100, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29128156

RESUMEN

PURPOSE: To investigate the safety and initial efficacy of XTRACT, a power aspiration-based extraction technique for treatment of peripheral arterial thromboembolism with the use of the Penumbra/Indigo system. MATERIALS AND METHODS: A total of 79 patients were enrolled: 39 (49.4%) underwent XTRACT as the initial therapy and 40 (50.6%) underwent XTRACT after failed catheter-directed thrombolysis or other mechanical intervention or for removal of distal emboli that occurred during an intervention. Occlusion locations were as follows: 36.7% (n = 29) in the profunda, common, or superficial femoral artery; 35.4% (n = 28) in the popliteal artery; 15.2% (n = 12) in the tibial artery; 7.6% (n = 6) in the peroneal artery; and the remainder in the common iliac (n = 1), external iliac (n = 1), sciatic (n = 1), and brachial (n = 1) arteries. RESULTS: Complete or near-complete revascularization (Thrombolysis In Myocardial Infarction [TIMI] grade 2/3 flow) was achieved in 87.2% of patients (68 of 78) immediately after the XTRACT procedure and before any other intervention. Successful revascularization was achieved in 79.5% of patients (31 of 39) as an initial treatment and in 92.5% (37 of 40) as salvage or secondary therapy. After additional adjunctive endovascular interventions, TIMI grade 2/3 flow was achieved in 96.2% of patients (76 of 79). Complete thrombus removal and restoration of normal flow (TIMI grade 3) was achieved in 77.2% of patients (61 of 79) after all endovascular treatment was completed. No patients required surgical revascularization. No device-related adverse events occurred. CONCLUSIONS: XTRACT was safe and effective for revascularization of acute or subacute peripheral arterial occlusions as a primary therapy or as a secondary therapy after other endovascular techniques had failed.


Asunto(s)
Procedimientos Endovasculares/instrumentación , Pierna/irrigación sanguínea , Enfermedad Arterial Periférica/cirugía , Trombectomía/instrumentación , Tromboembolia/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Estados Unidos
5.
J Vasc Interv Radiol ; 28(10): 1348-1352, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28941516

RESUMEN

The Indigo Mechanical Thrombectomy System (Penumbra, Inc, Alameda, California) was used to treat 6 patients with submassive pulmonary embolism (PE) and a contraindication to thrombolysis. Systolic pulmonary artery pressure (58.2 mm Hg vs 43.0 mm Hg, P < .05), right ventricular/left ventricular ratio (1.7 vs 1.1, P < .05), Miller index (15.0 vs 9.8, P < 0.01), and CT obstructive index (60.4% vs 47.0%, P < .01) were significantly reduced after mechanical thrombectomy. There were no procedural or periprocedural complications. Continuous aspiration mechanical thrombectomy is a feasible and promising technique for management of submassive PE to decrease thrombus burden and reduce right heart strain.


Asunto(s)
Embolia Pulmonar/cirugía , Trombectomía/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
6.
J Endovasc Ther ; 23(3): 468-71, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26969606

RESUMEN

PURPOSE: To assess the bleeding risk profile using the HAS-BLED score in patients with symptomatic peripheral artery disease (PAD). METHODS: A post hoc analysis was performed using data from a series of 115 consecutive patients (mean age 72.4±11.4 years; 68 men) with symptomatic PAD undergoing endovascular revascularization. The endpoint of the study was to assess bleeding risk using the 9-point HAS-BLED score, which was previously validated in cohorts of patients with and without atrial fibrillation. For the purpose of this study, the low (0-1), intermediate (2), and high-risk (≥3) scores were stratified as low/intermediate risk (HAS-BLED <3) vs high risk (HAS-BLED ≥3). RESULTS: The mean HAS-BLED score was 2.76±1.16; 64 (56%) patients had a HAS-BLED score ≥3.0. Patients with PAD Rutherford category 5/6 ischemia had an even higher mean HAS-BLED score (3.20±1.12). Logistic regression analysis revealed aortoiliac or femoropopliteal segment involvement, chronic kidney disease, as well as Rutherford category 5/6, to be independent risk factors associated with a HAS-BLED score ≥3. CONCLUSION: Patients with PAD, especially those presenting with Rutherford category 5/6 ischemic symptoms, have high HAS-BLED scores, suggesting increased risk for major bleeding. Prospective clinical validation of the HAS-BLED score in patients with PAD may help with the risk-benefit assessment when prescribing antithrombotic therapy.


Asunto(s)
Hemorragia/etiología , Isquemia/complicaciones , Enfermedad Arterial Periférica/complicaciones , Anciano , Anciano de 80 o más Años , Distribución de Chi-Cuadrado , Técnicas de Apoyo para la Decisión , Procedimientos Endovasculares/efectos adversos , Femenino , Fibrinolíticos/efectos adversos , Humanos , Isquemia/diagnóstico por imagen , Isquemia/terapia , Modelos Logísticos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Valor Predictivo de las Pruebas , Investigación Cualitativa , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
7.
J Vasc Interv Radiol ; 27(3): 330-5, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26803572

RESUMEN

PURPOSE: To assess the efficacy and safety of a vacuum-assisted thrombectomy (VAT) catheter system for treating patients with acute limb ischemia (ALI). MATERIALS AND METHODS: A retrospective study evaluated VAT systems (Penumbra, Alameda, California) in a consecutive series of 30 patients with ALI. ALI was defined as clinical symptoms within 2 weeks of presentation. The primary endpoint was improvement in blood flow across a lesion by improvement in Thrombolysis in Myocardial Infarction (TIMI) score that was adapted to peripheral arteries. Concomitant balloon angioplasty or stent placement in addition to VAT was considered a complementary treatment. Additional thrombectomy treatments, such as thrombolysis and mechanical thrombectomy, were considered technical failures. Target lesions were grouped anatomically into above-the-knee (ATK) or below-the-knee (BTK) lesions. RESULTS: In 30 patients, 33 lesions (ATK, n = 13; BTK, n = 20) were treated. No complications were attributed to the VAT systems. The primary endpoint was obtained in 24/33 (72.7%) lesions (BTK, 17/20 [85.0%]; ATK, 7/13 [53.9%]; P = .050 by χ(2) test). TIMI scores were similar at baseline but differed after VAT between the ATK and BTK groups (P < .025 by t test). ATK lesions required more concomitant angioplasty or stent placement, or both (P < .015 by χ(2) test). CONCLUSIONS: VAT is a safe, technically successful short-term therapeutic option for thrombus removal in patients with ALI.


Asunto(s)
Isquemia/terapia , Extremidad Inferior/irrigación sanguínea , Trombectomía/métodos , Enfermedad Aguda , Anciano , Anciano de 80 o más Años , Angioplastia de Balón/instrumentación , Distribución de Chi-Cuadrado , Femenino , Humanos , Isquemia/diagnóstico por imagen , Isquemia/fisiopatología , Masculino , Persona de Mediana Edad , Flujo Sanguíneo Regional , Estudios Retrospectivos , Factores de Riesgo , Stents , Trombectomía/efectos adversos , Trombectomía/instrumentación , Terapia Trombolítica , Factores de Tiempo , Resultado del Tratamiento , Vacio , Grado de Desobstrucción Vascular
8.
J Ultrasound Med ; 35(9): 1957-65, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27466261

RESUMEN

OBJECTIVES: Accreditation of cerebrovascular ultrasound laboratories by the Intersocietal Accreditation Commission (IAC) and equivalent organizations is supported by the Joint Commission certification of stroke centers. Limited information exists on the accreditation status and geographic distribution of cerebrovascular testing facilities in the United States. Our study objectives were to identify the proportion of IAC-accredited outpatient cerebrovascular testing facilities used by Medicare beneficiaries, describe their geographic distribution, and identify variations in cerebrovascular testing procedure types and volumes by accreditation status. METHODS: As part of the VALUE (Vascular Accreditation, Location, and Utilization Evaluation) Study, we examined the proportion of IAC-accredited facilities that conducted cerebrovascular testing in a 5% Centers for Medicare and Medicaid Services random Outpatient Limited Data Set in 2011 and investigated their geographic distribution using geocoding. RESULTS: Among 7327 outpatient facilities billing Medicare for cerebrovascular testing, only 22% (1640) were IAC accredited. The proportion of IAC-accredited cerebrovascular testing facilities varied by region (χ(2)[3] = 177.1; P < .0001), with 29%, 15%, 13%, and 10% located in the Northeast, South, Midwest, and West, respectively. However, of the total number of cerebrovascular outpatient procedures conducted in 2011 (38,555), 40% (15,410) were conducted in IAC-accredited facilities. Most cerebrovascular testing procedures were carotid duplex, with 40% of them conducted in IAC-accredited facilities. CONCLUSIONS: The proportion of facilities conducting outpatient cerebrovascular testing accredited by the IAC is low and varies by region. The growing number of certified stroke centers should be accompanied by more accredited outpatient vascular testing facilities, which could potentially improve the quality of stroke care.


Asunto(s)
Acreditación/métodos , Instituciones de Atención Ambulatoria/normas , Trastornos Cerebrovasculares/diagnóstico por imagen , Medicare , Ultrasonografía/normas , Trastornos Cerebrovasculares/diagnóstico , Humanos , Sociedades Médicas , Estados Unidos
9.
J Vasc Interv Radiol ; 25(8): 1149-56; quiz 1157, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24933285

RESUMEN

PURPOSE: To compare the safety and efficacy of ultrasound-accelerated thrombolysis (UAT) and standard catheter-directed thrombolysis (CDT) in patients with acute and subacute limb ischemia. MATERIALS AND METHODS: Medical records of all patients treated with thrombolysis for acute and subacute limb ischemia between August 2005 and January 2012 were reviewed. Coprimary (increase in ankle-brachial index, degree of lysis) and secondary endpoints (technical success, distal embolization, bleeding complications, need for additional interventions) were assessed. UAT was performed in 75 patients, and CDT was performed in 27 patients. Patients' baseline demographic and clinical parameters and procedure details, including lytic drug infusion rate (P = .704 and P = .987), total infusion time (P = .787 and P = .377), and use of adjunctive procedures (P = .457), did not differ significantly between the two groups. RESULTS: Complete lysis was achieved in 72.0% (UAT) and 63.0% (CDT) of patients (P = .542); hemodynamic success was achieved in 91.8% (UAT) and 92.3% (CDT) (P = .956). Overall major and minor bleeding complications were observed in 6.9% (UAT) and 3.9% (CDT) of patients. Major (P = .075) and minor (P = .276) bleeding independently did not differ between UAT and CDT. Major and minor bleeding combined was lower: 6.7% (UAT) versus 22.2% (CDT) (P = .025). Overall target vessel patency after 8.0 months (range, 1.5-20.5 mo) was 73.5%; target vessel patency for UAT was 75.9% versus 64.3% for CDT (P = .379). Median long-term survival was not significantly different between UAT and CDT: 3.6 years (range, 2.42-5.33 y) versus 1.8 years (range, 1.33-4.92 y) (P = .061). CONCLUSIONS: Both UAT and CDT are safe and efficient treatment modalities for patients with acute and subacute limb ischemia. The observed lower risk of total bleeding for UAT versus CDT may warrant prospective comparative trials.


Asunto(s)
Cateterismo Periférico , Fibrinolíticos/administración & dosificación , Isquemia/terapia , Enfermedad Arterial Periférica/terapia , Terapia Trombolítica , Activador de Tejido Plasminógeno/administración & dosificación , Terapia por Ultrasonido , Enfermedad Aguda , Anciano , Anciano de 80 o más Años , Cateterismo Periférico/efectos adversos , Femenino , Fibrinolíticos/efectos adversos , Hemorragia/etiología , Humanos , Infusiones Intraarteriales , Isquemia/diagnóstico , Isquemia/fisiopatología , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/diagnóstico , Enfermedad Arterial Periférica/fisiopatología , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Factores de Riesgo , Terapia Trombolítica/efectos adversos , Factores de Tiempo , Activador de Tejido Plasminógeno/efectos adversos , Resultado del Tratamiento , Terapia por Ultrasonido/efectos adversos , Grado de Desobstrucción Vascular
10.
Vasc Med ; 19(5): 376-84, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25179647

RESUMEN

OBJECTIVE: There is limited information on the accreditation status and geographic distribution of vascular testing facilities in the US. The Centers for Medicare & Medicaid Services (CMS) provide reimbursement to facilities regardless of accreditation status. The aims were to: (1) identify the proportion of Intersocietal Accreditation Commission (IAC) accredited vascular testing facilities in a 5% random national sample of Medicare beneficiaries receiving outpatient vascular testing services; (2) describe the geographic distribution of these facilities. METHODS: The VALUE (Vascular Accreditation, Location & Utilization Evaluation) Study examines the proportion of IAC accredited facilities providing vascular testing procedures nationally, and the geographic distribution and utilization of these facilities. The data set containing all facilities that billed Medicare for outpatient vascular testing services in 2011 (5% CMS Outpatient Limited Data Set (LDS) file) was examined, and locations of outpatient vascular testing facilities were obtained from the 2011 CMS/Medicare Provider of Services (POS) file. RESULTS: Of 13,462 total vascular testing facilities billing Medicare for vascular testing procedures in a 5% random Outpatient LDS for the US in 2011, 13% (n=1730) of facilities were IAC accredited. The percentage of IAC accredited vascular testing facilities in the LDS file varied significantly by US region, p<0.0001: 26%, 12%, 11%, and 7% for the Northeast, South, Midwest, and Western regions, respectively. CONCLUSIONS: Findings suggest that the proportion of outpatient vascular testing facilities that are IAC accredited is low and varies by region. Increasing the number of accredited vascular testing facilities to improve test quality is a hypothesis that should be tested in future research.


Asunto(s)
Acreditación , Instituciones de Atención Ambulatoria/normas , Diagnóstico por Imagen/normas , Accesibilidad a los Servicios de Salud/normas , Medicare/economía , Enfermedades Vasculares/diagnóstico , Anciano , Anciano de 80 o más Años , Atención Ambulatoria/normas , Atención Ambulatoria/tendencias , Bases de Datos Factuales , Diagnóstico por Imagen/estadística & datos numéricos , Femenino , Accesibilidad a los Servicios de Salud/estadística & datos numéricos , Humanos , Masculino , Medicare/estadística & datos numéricos , Persona de Mediana Edad , Estados Unidos
11.
AJR Am J Roentgenol ; 200(4): 915-20, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23521470

RESUMEN

OBJECTIVE: Radiation exposure to interventionalists is increasing. The currently available standard radiation protection devices are heavy and do not protect the head of the operator. The aim of this study was to evaluate the effectiveness and comfort of caps and thyroid collars made of a disposable, light-weight, lead-free material (XPF) for occupational radiation protection in a clinical setting. SUBJECTS AND METHODS: Up to two interventional operators were randomized to wear a XPF or standard 0.5-mm lead-equivalent thyroid collars in 60 consecutive endovascular procedures requiring fluoroscopy. Simultaneously a XPF cap was worn by all operators. Radiation doses were measured using dosimeters placed outside and underneath the caps and thyroid collars. Wearing comfort was assessed at the end of each procedure on a visual analog scale (0-100 [100 = optimal]). RESULTS: Patient and procedure data did not differ between the XPF and standard protection groups. The cumulative radiation dose measured outside the cap was 15,700 µSv and outside the thyroid collars 21,240 µSv. Measured radiation attenuation provided by the XPF caps (n = 70), XPF thyroid collars (n = 40), and standard thyroid collars (n = 38) was 85.4% ± 25.6%, 79.7% ± 25.8% and 71.9% ± 34.2%, respectively (mean difference XPF vs standard thyroid collars, 7.8% [95% CI, -5.9% to 21.6%]; p = 0.258). The median XPF cap weight was 144 g (interquartile range, 128-170 g), and the XPF thyroid collars were 27% lighter than the standard thyroid collars (p < 0.0001). Operators rated the comfort of all devices as high (mean scores for XPF caps and XPF thyroid collars 83.4 ± 12.7 (SD) and 88.5 ± 14.6, respectively; mean scores for standard thyroid collars 89.6 ± 9.9) (p = 0.648). CONCLUSION: Light-weight disposable caps and thyroid collars made of XPF were assessed as being comfortable to wear, and they provide radiation protection similar to that of standard 0.5-mm lead-equivalent thyroid collars.


Asunto(s)
Equipos Desechables , Fluoroscopía/instrumentación , Exposición Profesional/prevención & control , Equipos de Seguridad , Traumatismos por Radiación/prevención & control , Protección Radiológica/instrumentación , Radiografía Intervencional/instrumentación , Distribución de Chi-Cuadrado , Humanos , Estudios Prospectivos , Dosis de Radiación , Estadísticas no Paramétricas
12.
J Vasc Surg ; 56(4): 965-72, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22727839

RESUMEN

BACKGROUND: This study presents the short-term and midterm results of direct percutaneous sac injection (DPSI) for postoperative endoleak treatment after endovascular aortic aneurysm repair (EVAR). METHODS: Between March 1994 and November 2011, EVAR was performed in 986 patients. The median follow-up was 63 ± 45 months (range, 0-211 months). A retrospective analysis was performed. DPSI was used in 21 patients for 19 type II endoleaks and two endoleaks of undefined origin (EOUO), of which 12 (57%) were after failure of a previous endovascular treatment attempt. RESULTS: DPSI using thrombin (n = 16), coils (n = 7), gelfoam (n = 6), or glue (n = 3), or a combination, was technically feasible in all patients. Saccography during DPSI revealed a previously undetected type I endoleak in three patients. Immediate DPSI success was achieved in 16 of 18 procedures (88.9%), with two complications. Glue incidentally intravasated in the inferior vena cava, causing a clinically nonsignificant subsegmental pulmonary artery embolism in one patient, and the temporary development of a type III endoleak, possibly from graft puncture, in another. During a median follow-up of 39 months (interquartile range, 13-88 months) after DPSI, recurrent endoleaks were observed in nine patients (50.0%), one type I endoleak due to graft migration, five type II endoleaks, and three EOUO. The occurrence of a re-endoleak during follow-up was significantly associated with dual-antiplatelet medication (0% in patients without re-endoleak vs 44.4% in patients with re-endoleak; P = .023) and with a nonsignificant trend for the use of aspirin alone (33.3% in patients without re-endoleak vs 80% in patients with re-endoleak; P = .094). Re-endoleak occurred in 33.3% of the patients without antiplatelet medication and in 100% of patients with dual-antiplatelet medication (P = .026). Thrombin was used as the sole embolic agent during the initial DPSI in all patients with dual-antiplatelet therapy. No other factor was significantly associated with re-endoleaks. Reintervention was deemed necessary in six patients within a median of 10 months (interquartile range, 4-16 months) after DPSI, including six additional DPSI treatments in four patients with type II re-endoleaks, cuff placements in one type I endoleak, and endograft relining in one EOUO. CONCLUSIONS: This initial experience suggests that DPSI is feasible as a technique for endoleak treatment after EVAR. However, complications and endoleak recurrence remain a concern. The role of antiplatelet therapy and different embolic agents on long-term embolization success needs to be studied in more detail.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Embolización Terapéutica , Endofuga/terapia , Procedimientos Endovasculares , Hemostáticos/administración & dosificación , Anciano , Anciano de 80 o más Años , Prótesis Vascular , Endofuga/diagnóstico , Endofuga/etiología , Estudios de Factibilidad , Femenino , Humanos , Inyecciones , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
13.
J Interv Cardiol ; 25(2): 197-202, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21981617

RESUMEN

PURPOSE: To analyze and report the safety and effectiveness of bivalirudin in a large patient population undergoing carotid artery stenting (CAS). METHODS: Between January 2001 and November 2010 extracranial CAS was performed in 272 patients in our institution. These patients were stratified according to the anticoagulant used during the CAS procedure into 2 groups (bivalirudin n = 217 vs. unfractionated heparin [UFH] n = 55) and analyzed regarding bleeding complications and periprocedural (within 30 days) stroke and myocardial infarction (MI) rates. RESULTS: The combined end-point of death, stroke, and MI occurred in 12 patients (4.4%) with no significant difference between the groups (bivalirudin 4.6% vs. UFH 3.6% P value 0.96). Stroke rates were 1.8% in the bivalirudin and 1.8% in the UFH group (P value 1.00), with 4/5 strokes being nondisabling. Periprocedural MI was observed in 7 patients (2.1%) with no significant differences between the groups (bivalirudin 2.7% vs. UFH 1.8%, P value 0.94). Bleeding complications occurred in 13/272 patients (4.7%) with no significant difference between the groups (bivalirudin 3.6% vs. UFH 9.0%, P value 0.15). The first activated clotting time after administration of the anticoagulants was therapeutic in 209/217 (96%) in the bivalirudin group and in 30/55 (55%) in the UFH group (P < 0.001). CONCLUSIONS: In this single-center study, bivalirudin was a safe and efficient anticoagulation strategy for CAS and could be considered a therapeutic alternative to UFH.


Asunto(s)
Antitrombinas/uso terapéutico , Estenosis Carotídea/tratamiento farmacológico , Fragmentos de Péptidos/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Clopidogrel , Femenino , Hirudinas , Humanos , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/administración & dosificación , Proteínas Recombinantes/uso terapéutico , Ticlopidina/administración & dosificación , Ticlopidina/análogos & derivados
15.
J Vasc Interv Radiol ; 23(11): 1460-6, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23101918

RESUMEN

PURPOSE: To compare the thrombolytic efficacy and safety of standard catheter-directed thrombolysis (CDT) and ultrasound (US)-accelerated thrombolysis (UAT) for the treatment of iliofemoral deep vein thrombosis (DVT). MATERIALS AND METHODS: All medical records of patients who underwent CDT or UAT for DVT between June 2004 and October 2011 at a single tertiary care center were reviewed. Target vein patency was graded according to a reporting standard by an independent interventional radiologist. RESULTS: CDT was performed in 19 patients and UAT in 64 patients. The baseline parameters and DVT characteristics, including the duration of symptoms, the location, and the extension did not differ significantly between groups. Both treatment modalities were associated with a similar substantial resolution of thrombus load (CDT = 89%; interquartile range [IQR], 70%-100%; UAT = 82%; IQR, 55%-92% (P = .560). No significant differences in the lytic drug infusion rates, the total lytic doses, the total infusion time, and the use of adjunctive procedures were observed between groups. Major and minor bleeding complications were observed in 8.4% and 4.8% of the patients, with no difference between the treatment groups (P = .709 and P = .918, respectively). During a median follow-up of 35 months (20-55 months), three deaths and 16 cases of repeated thrombosis were observed. The estimated mean event-free survival time was longer after CDT (69 mo) compared with UAT (33 mo) (log-rank test P = .310). CONCLUSIONS: The present study failed to prove any substantial clinical benefit provided by UAT with regard to effectiveness or safety compared with standard CDT. Given the added costs of the US delivery device, prospective randomized data are needed to justify its widespread use for DVT treatment.


Asunto(s)
Cateterismo Periférico , Vena Femoral , Vena Ilíaca , Terapia Trombolítica/métodos , Terapia por Ultrasonido , Trombosis de la Vena/terapia , Adulto , Anciano , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/mortalidad , Distribución de Chi-Cuadrado , Supervivencia sin Enfermedad , Femenino , Vena Femoral/diagnóstico por imagen , Vena Femoral/fisiopatología , Florida , Humanos , Vena Ilíaca/diagnóstico por imagen , Vena Ilíaca/fisiopatología , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Flebografía , Modelos de Riesgos Proporcionales , Recurrencia , Estudios Retrospectivos , Centros de Atención Terciaria , Terapia Trombolítica/efectos adversos , Terapia Trombolítica/mortalidad , Factores de Tiempo , Resultado del Tratamiento , Terapia por Ultrasonido/efectos adversos , Terapia por Ultrasonido/mortalidad , Grado de Desobstrucción Vascular , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/mortalidad , Trombosis de la Vena/fisiopatología
16.
J Vasc Interv Radiol ; 23(4): 468-75, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22301335

RESUMEN

PURPOSE: To report the experience with thoracic endovascular aortic repair (TEVAR) in a single center over a 15-year period. MATERIALS AND METHODS: All patients undergoing TEVAR during the period 1994-2009 were retrospectively evaluated. RESULTS: The study comprised 133 patients (96 men, age 69.5 years ± 14.7) who underwent 21 emergency and 112 elective TEVAR procedures. Aortic pathologies included 91 aneurysms, 14 pseudoaneurysms, 14 penetrating ulcers with or without pseudoaneurysms or intramural hematomas, 8 type B dissections (3 acute and 5 chronic), and 6 traumatic transections. Technical success was 97.7% with a 30-day mortality of 7.5%. There were 101 patients followed to 1 year, 35 patients followed to 5 years, and 6 patients followed to 10-15 years. The overall estimated survivals at 1 year, 5 years, and 10 years were 81%, 48%, and 36%. The 30-day mortality rates in emergency and elective TEVAR procedures were 23.9% and 4.5% (P = .005). However, among patients who survived > 30 days, there was no significant difference in mortality between groups undergoing emergency and elective TEVAR procedures (P = .9, hazard ratio [HR] 0.94, confidence interval [CI] 0.4-2.2). There was no significant gender survival difference. The 30-day mortality rate in octogenarians (n = 31) was higher than in younger patients (P = .03). Incidences of stroke and paraplegia within 30 days of TEVAR were 6.8% and 2.2%. Endoleaks were found in 39 (29%) patients, and secondary interventions were performed in 6 (4.5%) patients. CONCLUSIONS: The data support the safety and efficacy of TEVAR for aortic pathologies with a low mortality rate. Younger patients have fewer complications after TEVAR. After the acute perioperative period, TEVAR procedures performed emergently are as durable as the procedures performed electively.


Asunto(s)
Aneurisma de la Aorta Torácica/mortalidad , Aneurisma de la Aorta Torácica/cirugía , Procedimientos Endovasculares/mortalidad , Radiografía Intervencional/mortalidad , Adolescente , Adulto , Anciano , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Prevalencia , Medición de Riesgo , Factores de Riesgo , Análisis de Supervivencia , Tasa de Supervivencia , Resultado del Tratamiento , Estados Unidos/epidemiología , Adulto Joven
17.
J Vasc Interv Radiol ; 23(9): 1152-9.e6, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22854317

RESUMEN

PURPOSE: To investigate the current clinical practice in postoperative endovascular aneurysm repair (EVAR) imaging surveillance. MATERIALS AND METHODS: Corresponding authors of EVAR publications during the years 2006-2011 and subscribers to an endovascular journal were invited to complete a 27-question online survey related to institutional demographics, standard post-EVAR imaging surveillance, and imaging protocols in special circumstances (eg, renal insufficiency). RESULTS: The survey was completed by 515 of 9,631 physicians performing EVAR from 52 countries. Of respondents, 65.3% were affiliated with experienced centers where EVAR has been performed for > 10 years or with > 50 EVAR procedures performed per year. Computed tomography (CT) angiography was the modality used most often for standard surveillance with a maximum time interval between studies of 12 months in 78.8% of centers out to 5 years. Experienced centers were more likely to delay follow-up imaging to 1 year after an unremarkable initial post-EVAR imaging study (P < .001), to extend surveillance intervals > 12 months (P = .043), and to use ultrasound (P < .01) for surveillance. After the detection of a type II endoleak, CT angiography was favored for follow-up by 59.4% of the respondents. Experienced centers were more likely to favor ultrasound (P = .006) and to schedule this follow-up examination later (after 6-12 months, P < .001). Of respondents, 62.8% used a glomerular filtration rate threshold of < 30 mL/min for not performing contrast-enhanced CT scan. In patients with renal insufficiency, most respondents performed ultrasound with or without a concomitant noncontrast CT scan. CONCLUSIONS: CT is the most frequently used method of long-term surveillance after EVAR. Use of ultrasound for long-term surveillance, extension of follow-up time intervals, or both were most often reported in experienced centers.


Asunto(s)
Aneurisma/cirugía , Diagnóstico por Imagen/tendencias , Procedimientos Endovasculares , Complicaciones Posoperatorias/diagnóstico , Pautas de la Práctica en Medicina/tendencias , Aneurisma/complicaciones , Aneurisma/diagnóstico , Distribución de Chi-Cuadrado , Medios de Contraste/efectos adversos , Endofuga/diagnóstico , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Encuestas de Atención de la Salud , Humanos , Imagen por Resonancia Magnética/tendencias , Cuidados Posoperatorios/tendencias , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Valor Predictivo de las Pruebas , Insuficiencia Renal/complicaciones , Encuestas y Cuestionarios , Factores de Tiempo , Tomografía Computarizada por Rayos X/tendencias , Transductores de Presión/tendencias , Resultado del Tratamiento , Ultrasonografía Doppler en Color/tendencias
18.
Tech Vasc Interv Radiol ; 25(3): 100841, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35842260

RESUMEN

Arterial calcification (AC) is a common complication among patients with peripheral arterial disease (PAD). AC presents various challenges to PAD treatment including an increased likelihood of vessel rupture and dissection, and by acting as a physical barrier to drug delivery by angioplasty balloons. Intravascular lithotripsy (IVL) is a novel intervention that specifically targets AC by emitting sonic pressure waves that introduce microfractures in target calcified lesions to increase arterial compliance. Preliminary data has demonstrated the safety and efficacy of IVL in PAD treatment. The present article provides a technical overview of S-IVL, as well as a case series of the treatment of AC in common iliac, common femoral, superficial femoral, aortoiliac, and peroneal arterial lesions. Each case resulted in marked improvement of luminal patency, exhibiting the efficacy IVL.


Asunto(s)
Litotricia , Enfermedad Arterial Periférica , Calcificación Vascular , Arteria Femoral , Humanos , Litotricia/efectos adversos , Litotricia/métodos , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/etiología , Enfermedad Arterial Periférica/terapia , Resultado del Tratamiento , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/etiología , Calcificación Vascular/terapia
19.
J Vasc Surg ; 54(6): 1605-13, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21908147

RESUMEN

OBJECTIVE: The purpose of this report was to present short and midterm results of endovascular aortic aneurysm repair (EVAR) of infrarenal aortic aneurysms in octogenarians and nonagenarians. METHODS: Between March 1994 and March 2011, elective EVAR was performed in 967 patients in our institution. This includes 279 patients older than 80 years at the time of the procedure (octogenarians: n = 252, nonagenarians: n = 27). Mean follow-up was 48.4 ± 34.5 months. A retrospective analysis was performed. Survival was calculated using Kaplan-Meier analysis and a survival comparison to patients who underwent EVAR <80 years old (n = 688) was performed. Cox hazard regression analysis was used to assess parameters that influence survival. RESULTS: Technical success was 96% in octogenarians and 85% in nonagenarians. Technical failure in 15 of 279 patients includes primary type I endoleak (n = 6), procedure abortion due to inability to pass the iliac vessels (n = 6), and emergency conversion (n = 3). Thirty-day mortality was significantly higher for patients >80 years old (2.8% vs 1.0%; P = .044). Morbidity rates were 11.5% for octogenarians and 7.4% for nonagenarians with predominately cardiopulmonary complications. High-risk patients >80 years old showed a comparable perioperative mortality rate to low-/medium-risk patients >80 years old (2.9% vs 2.5%;P = .717), but a significantly higher complication rate (22.5% vs 9.2%; P = .0275) and reduced midterm survival with 1-, 3-, and 5-year survival rates of 79% ± SE 7%, 55% ± SE 8%, and 38% ± SE 9% (log-rank test P = .03). In high-risk patients age >80 years old, their age did not influence 30-day mortality (2.5% vs 2.7%; P = .978) and midterm survival. Survival in octogenarians at 1, 3, and 5 years was 87.9 ± SE 2.1%, 70.9 ± SE 3.0%, and 55.6% ± SE 3.5%, respectively. Survival in nonagenarians at 1 and 3 years was 96.3% ± SE 4% and 60.6% ± SE 10.4%. Higher cardiac (hazard ratio [HR], 1.22; P = .038) and renal risk scores (HR, 1.59; P = .0016), chronic obstructive pulmonary disease (HR, 1.56; P = .032), and anemia (HR, 2.1; P < .001) influenced midterm survival. CONCLUSION: EVAR in octogenarians and nonagenarians is associated with a significantly higher but still low perioperative mortality compared to younger patients. Midterm survival in octogenarians and nonagenarians, although significantly lower than in younger patients, is still acceptable, indicating that age >80 years should not be an exclusion criteria for EVAR. Even high-risk patients >80 years can be treated safely with a low perioperative mortality and comparable midterm outcome to younger high-risk patients.


Asunto(s)
Factores de Edad , Aneurisma de la Aorta Abdominal/cirugía , Procedimientos Endovasculares , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/mortalidad , Estudios de Cohortes , Femenino , Humanos , Masculino , Selección de Paciente , Reoperación , Tasa de Supervivencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA