Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 214
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(7): 538-548, 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38195003

RESUMEN

BACKGROUND AND AIMS: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death (SCD) in arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to identify cross-continental differences in utilization of primary prevention ICDs and survival free from sustained ventricular arrhythmia (VA) in ARVC. METHODS: This was a retrospective analysis of ARVC patients without prior VA enrolled in clinical registries from 11 countries throughout Europe and North America. Patients were classified according to whether they received treatment in North America or Europe and were further stratified by baseline predicted VA risk into low- (<10%/5 years), intermediate- (10%-25%/5 years), and high-risk (>25%/5 years) groups. Differences in ICD implantation and survival free from sustained VA events (including appropriate ICD therapy) were assessed. RESULTS: One thousand ninety-eight patients were followed for a median of 5.1 years; 554 (50.5%) received a primary prevention ICD, and 286 (26.0%) experienced a first VA event. After adjusting for baseline risk factors, North Americans were more than three times as likely to receive ICDs {hazard ratio (HR) 3.1 [95% confidence interval (CI) 2.5, 3.8]} but had only mildly increased risk for incident sustained VA [HR 1.4 (95% CI 1.1, 1.8)]. North Americans without ICDs were at higher risk for incident sustained VA [HR 2.1 (95% CI 1.3, 3.4)] than Europeans. CONCLUSIONS: North American ARVC patients were substantially more likely than Europeans to receive primary prevention ICDs across all arrhythmic risk strata. A lower rate of ICD implantation in Europe was not associated with a higher rate of VA events in those without ICDs.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Displasia Ventricular Derecha Arritmogénica/complicaciones , Displasia Ventricular Derecha Arritmogénica/epidemiología , Displasia Ventricular Derecha Arritmogénica/terapia , Estudios Retrospectivos , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Factores de Riesgo , América del Norte/epidemiología , Europa (Continente)/epidemiología
2.
Europace ; 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39120658

RESUMEN

BACKGROUND: Physiological activation of the heart using algorithms to minimize right ventricular pacing (RVPm) may be an effective strategy to reduce adverse events in patients requiring anti-bradycardia therapies. This systematic review and meta-analysis aimed to evaluate current evidence on clinical outcomes for patients treated with RVPm algorithms compared to dual chamber pacing (DDD). METHODS AND RESULTS: We conducted a systematic search of the PubMed database. The predefined endpoints were the occurrence of persistent/permanent atrial fibrillation (PerAF), cardiovascular (CV) hospitalization, all-cause death, and adverse symptoms. We also aimed to explore the differential effects of algorithms in studies enrolling a high percentage of atrioventricular block (AVB) patients. Eight studies (7229 patients) were included in the analysis. Compared to DDD-pacing, patients using RVPm algorithms showed a lower risk of PerAF (Odds Ratio [OR] 0.74, 95% confidence interval [CI] 0.57-0.97) and CV hospitalization (OR 0.77, 95% CI 0.61-0.97). No significant difference was found for all-cause death (OR 1.01, 95% CI 0.78-1.30) or adverse symptoms (OR 1.03, 95% CI 0.81-1.29). No significant interaction was found between the use of the RVPm strategy and studies enrolling a high percentage of AVB patients. The pooled mean RVP percentage for RVPm algorithms was 7.96% (95% CI 3.13-20.25), as compared with 45.11% (95% CI 26.64-76.38) of DDD-pacing. CONCLUSION: Algorithms for RVPm may be effective in reducing the risk of PerAF and CV hospitalization in patients requiring anti-bradycardia therapies, without an increased risk of adverse symptoms. These results are also consistent for studies enrolling a high percentage of AVB patients.

3.
Artículo en Inglés | MEDLINE | ID: mdl-39072776

RESUMEN

BACKGROUND: The programing of subcutaneous implantable cardioverter-defibrillators (S-ICD) in clinical practice has been little studied, as the activation status of the SMART Pass filter, which was implemented to reduce inappropriate shocks. PURPOSE: We assessed device programing during follow-up and the rate of detected arrhythmias in consecutive S-ICD recipients. METHODS: We analyzed data from 670 S-ICD patients followed on the remote network at 17 Italian centers for a median of 31 months (25th-75th percentile: 16-51). The enhanced SMART Pass version, introduced in October 2022, was expected to reduce the unintentional deactivation rate. RESULTS: At the latest remote data transmission, the median conditional zone cut-off was set to 210 bpm (25th-75th percentile: 200-220), the shock zone cutoff was 250 bpm (25th-75th percentile: 240-250), and the SMART Pass was enabled in 586 (87%) patients. During follow-up, 194 automatic deactivation events were reported in 118 (18%) patients. Shocks were delivered in 129 (19%) patients, and untreated arrhythmias were recorded in 136 (20%) patients. The rate of shocks was lower when SMART Pass was enabled -0.12/patient-year (95% CI: 0.10-0.14) versus 0.20 (95% CI: 0.15-0.26) (p = .002), as it was the rate of untreated arrhythmias -0.12/patient-year (95% CI: 0.11-0.14) versus 0.23 (95% CI: 0.18-0.30) (p = .001). The enhanced SMART Pass version was associated with a lower rate of deactivations -0.04/patient-year (95% CI: 0.02-0.05) versus 0.14 (95% CI: 0.12-0.16) (p < .001), and with a reduction in treated and untreated arrhythmias (Incidence rate ratios: 0.40 (95% CI: 0.28-0.53) and 0.40 (95% CI: 0.30-0.55), respectively (p < .001)). CONCLUSIONS: Centers tend to program devices to detect high ventricular rates for arrhythmia detection, to minimize inappropriate shock occurrences. SMART Pass activation is associated with lower rates of detected and treated arrhythmias. The enhanced SMART Pass version seems associated with a lower deactivation rate and with a further decrease in treated arrhythmias.

4.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-36974970

RESUMEN

AIMS: In patients with prolonged atrioventricular (AV) conduction and pacemaker (PM) indication due to sinus node disease (SND) or intermittent AV-block who do not need continuous ventricular pacing (VP), it may be difficult to determine which strategy to adopt. Currently, the standard of care is to minimize unnecessary VP by specific VP avoidance (VPA) algorithms. The superiority of this strategy over standard DDD or DDD rate-responsive (DDD/DDDR) in improving clinical outcomes is controversial, probably owing to the prolongation of the atrialventricular conduction (PR interval) caused by the algorithms. Conduction system pacing (CSP) may offer the most physiological-VP approach, providing appropriate AV conduction and preventing pacing-induced dyssynchrony. METHODS AND RESULTS: PhysioVP-AF is a prospective, controlled, randomized, single-blind trial designed to determine whether atrial-synchronized conduction system pacing (DDD-CSP) is superior to standard DDD-VPA pacing in terms of 3-year reduction of persistent-AF occurrence. Cardiovascular hospitalization, quality-of-life, and safety will be evaluated. Patients with indication for permanent DDD pacing for SND or intermittent AV-block and prolonged AV conduction (PR interval > 180 ms) will be randomized (1:1 ratio) to DDD-VPA (VPA-algorithms ON, septal/apex position) or to DDD-CSP (His bundle or left bundle branch area pacing, AV-delay setting to control PR interval, VPA-algorithms OFF). Approximately 400 patients will be randomized in 24 months in 13 Italian centres. CONCLUSION: The PhysioVP-AF study will provide an essential contribution to patient management with prolonged AV conduction and PM indication for sinus nodal disease or paroxysmal 2nd-degree AV-block by determining whether CSP combined with a controlled PR interval is superior to standard management that minimizes unnecessary VP in terms of reducing clinical outcomes.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Marcapaso Artificial , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Estudios Prospectivos , Método Simple Ciego , Síndrome del Seno Enfermo/complicaciones , Síndrome del Seno Enfermo/diagnóstico , Síndrome del Seno Enfermo/terapia
5.
Europace ; 25(4): 1467-1474, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36881780

RESUMEN

AIMS: Patients with atrial fibrillation frequently experience sleep disorder breathing, and both conditions are highly prevalent in presence of heart failure (HF). We explored the association between the combination of an HF and a sleep apnoea (SA) index and the incidence of atrial high-rate events (AHRE) in patients with implantable defibrillators (ICDs). METHODS AND RESULTS: Data were prospectively collected from 411 consecutive HF patients with ICD. The IN-alert HF state was measured by the multi-sensor HeartLogic Index (>16), and the ICD-measured Respiratory Disturbance Index (RDI) was computed to identify severe SA. The endpoints were as follows: daily AHRE burden of ≥5 min, ≥6 h, and ≥23 h. During a median follow-up of 26 months, the time IN-alert HF state was 13% of the total observation period. The RDI value was ≥30 episodes/h (severe SA) during 58% of the observation period. An AHRE burden of ≥5 min/day was documented in 139 (34%) patients, ≥6 h/day in 89 (22%) patients, and ≥23 h/day in 68 (17%) patients. The IN-alert HF state was independently associated with AHRE regardless of the daily burden threshold: hazard ratios from 2.17 for ≥5 min/day to 3.43 for ≥23 h/day (P < 0.01). An RDI ≥ 30 episodes/h was associated only with AHRE burden ≥5 min/day [hazard ratio 1.55 (95% confidence interval: 1.11-2.16), P = 0.001]. The combination of IN-alert HF state and RDI ≥ 30 episodes/h accounted for only 6% of the follow-up period and was associated with high rates of AHRE occurrence (from 28 events/100 patient-years for AHRE burden ≥5 min/day to 22 events/100 patient-years for AHRE burden ≥23 h/day). CONCLUSIONS: In HF patients, the occurrence of AHRE is independently associated with the ICD-measured IN-alert HF state and RDI ≥ 30 episodes/h. The coexistence of these two conditions occurs rarely but is associated with a very high rate of AHRE occurrence. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Síndromes de la Apnea del Sueño , Humanos , Desfibriladores Implantables/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Medición de Riesgo , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia
6.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37656991

RESUMEN

AIMS: The HeartLogic Index combines data from multiple implantable cardioverter defibrillators (ICDs) sensors and has been shown to accurately stratify patients at risk of heart failure (HF) events. We evaluated and compared the performance of this algorithm during sinus rhythm and during long-lasting atrial fibrillation (AF). METHODS AND RESULTS: HeartLogic was activated in 568 ICD patients from 26 centres. We found periods of ≥30 consecutive days with an atrial high-rate episode (AHRE) burden <1 h/day and periods with an AHRE burden ≥20 h/day. We then identified patients who met both criteria during the follow-up (AHRE group, n = 53), to allow pairwise comparison of periods. For control purposes, we identified patients with an AHRE burden <1 h throughout their follow-up and implemented 2:1 propensity score matching vs. the AHRE group (matched non-AHRE group, n = 106). In the AHRE group, the rate of alerts was 1.2 [95% confidence interval (CI): 1.0-1.5]/patient-year during periods with an AHRE burden <1 h/day and 2.0 (95% CI: 1.5-2.6)/patient-year during periods with an AHRE-burden ≥20 h/day (P = 0.004). The rate of HF hospitalizations was 0.34 (95% CI: 0.15-0.69)/patient-year during IN-alert periods and 0.06 (95% CI: 0.02-0.14)/patient-year during OUT-of-alert periods (P < 0.001). The IN/OUT-of-alert state incidence rate ratio of HF hospitalizations was 8.59 (95% CI: 1.67-55.31) during periods with an AHRE burden <1 h/day and 2.70 (95% CI: 1.01-28.33) during periods with an AHRE burden ≥20 h/day. In the matched non-AHRE group, the rate of HF hospitalizations was 0.29 (95% CI: 0.12-0.60)/patient-year during IN-alert periods and 0.04 (95% CI: 0.02-0.08)/patient-year during OUT-of-alert periods (P < 0.001). The incidence rate ratio was 7.11 (95% CI: 2.19-22.44). CONCLUSION: Patients received more alerts during periods of AF. The ability of the algorithm to identify increased risk of HF events was confirmed during AF, despite a lower IN/OUT-of-alert incidence rate ratio in comparison with non-AF periods and non-AF patients. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/Identifier: NCT02275637.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Algoritmos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Atrios Cardíacos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia
7.
Rev Cardiovasc Med ; 23(1): 1, 2022 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-35092193

RESUMEN

BACKGROUND: A 61-year-old male with Steinert Dystrophy and prior history of cardiac implantable device complained of highly symptomatic right atrial tachycardia. Unresponsive to pharmacological therapy. METHODS: The patient underwent catheter ablation procedure aided by high-density mapping. RESULTS: Ablation procedure was succesful. CONCLUSIONS: This unique case report highlights the role of high-density mapping in the identification of critical isthmus and management of macro-reentrant tachycardia in complex situations such as the presence of multiple leads in the chamber.


Asunto(s)
Ablación por Catéter , Taquicardia Supraventricular , Taquicardia Ventricular , Ablación por Catéter/efectos adversos , Atrios Cardíacos , Humanos , Masculino , Persona de Mediana Edad , Taquicardia Supraventricular/etiología
8.
Rev Cardiovasc Med ; 23(4): 125, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-39076223

RESUMEN

Background: A 70 years-old superobese man (weighted 230 kg) was referred to our hospital for recurrent syncope due to asystole alternating to atrial fibrillation. Convectional pacing was highly challenging; therefore, it was decided to implant a leadless pacemaker in a multidisciplinary intervention with surgical management of the femoral venous access. Methods: In a fully equipped operating room with bariatric table and appropriately dimensioned fluoroscope, a vascular surgeon performed surgical isolation of the right common femoral vein. After that, we proceeded to insert sheaths via the femoral vein, and through that a steerable transcatheter delivery system for the device. Results: The implant was successful without complication. Conclusions: Leadless pacemaker implantation can be effectively and safely performed even in superobese patients. Vascular access, fluoroscopic guidance and electronic interrogation could be easily managed and do not constitute a limit.

9.
Europace ; 24(3): 413-420, 2022 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-34487163

RESUMEN

AIMS: In patients undergoing cardiac implantable electronic device (CIED) intervention, routine pre-procedure antibiotic prophylaxis is recommended. A more powerful antibiotic protocol has been suggested in patients at high risk of infection. Stratification of individual infective risk could guide the prophylaxis before CIED procedure. METHODS AND RESULTS: Patients undergoing CIED surgery were stratified according to the Shariff score in low and high infective risk. Patients in the 'low-risk' group were treated with only two antibiotic administrations while patients in the 'high-risk' group were treated with a prolonged 9-day protocol, according to renal function and allergies. We followed-up patients for 250 days with clinical outpatient visit and electronic control of the CIED. As primary endpoint, we evaluated CIED-related infections. A total of 937 consecutive patients were enrolled, of whom 735 were stratified in the 'low-risk' group and 202 in the 'high-risk' group. Despite different risk profiles, CIED-related infection rate at 250 days was similar in the two groups (8/735 in 'low risk' vs. 4/202 in 'high risk', P = 0.32). At multivariate analysis, active neoplasia, haematoma, and reintervention were independently associated with CIED-related infection (HR 5.54, 10.77, and 12.15, respectively). CONCLUSION: In a large cohort of patients undergoing CIED procedure, an antibiotic prophylaxis based on individual stratification of infective risk resulted in similar rate of infection between groups at high and low risk of CIED-related infection.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Antibacterianos/uso terapéutico , Profilaxis Antibiótica/métodos , Desfibriladores Implantables/efectos adversos , Electrónica , Humanos , Marcapaso Artificial/efectos adversos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/prevención & control , Medición de Riesgo , Factores de Riesgo
10.
Medicina (Kaunas) ; 59(1)2022 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-36676690

RESUMEN

Background. Data on leadless pacemaker (LPM) implantation in an emergency setting are currently lacking. Objective. We aimed to investigate the feasibility of LPM implantation for emergency bradyarrhythmia, in patients referred for urgent PM implantation, in a large, multicenter, real-world cohort of LPM recipients. Methods. Two cohorts of LPM patients, stratified according to the LPM implantation scenario (patients admitted from the emergency department (ED+) vs. elective patients (ED−)) were retrieved from the iLEAPER registry. The primary outcome of the study was a comparison of the peri-procedural complications between the groups. The rates of peri-procedural characteristics (overall procedural and fluoroscopic duration) were deemed secondary outcomes. Results. A total of 1154 patients were enrolled in this project, with patients implanted due to an urgent bradyarrhythmia (ED+) representing 6.2% of the entire cohort. Slow atrial fibrillation and complete + advanced atrioventricular blocks were more frequent in the ED+ cohort (76.3% for ED+ vs. 49.7% for ED−, p = 0.025; 37.5% vs. 27.3%, p = 0.027, respectively). The overall procedural times were longer in the ED+ cohort (60 (45−80) mins vs. 50 (40−65) mins, p < 0.001), showing higher rates of temporary pacing (94.4% for ED+ vs. 28.9% for ED−, p < 0.001). Emergency LPM implantation was not correlated with an increase in the rate of major complications compared to the control group (6.9% ED+ vs. 4.2% ED−, p = 0.244). Conclusion. LPM implantation is a feasible procedure for the treatment of severe bradyarrhythmia in an urgent setting. Urgent LPM implantation was not correlated with an increase in the rate of major complications compared to the control group, but it was associated with longer procedural times.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Humanos , Bradicardia/terapia , Fibrilación Atrial/terapia , Resultado del Tratamiento
11.
Pacing Clin Electrophysiol ; 44(6): 1033-1038, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-34022067

RESUMEN

BACKGROUND: In Italy, a nationwide full lockdown was declared between March and May 2020 to hinder the novel coronavirus disease 2019 (COVID-19) pandemic. The potential individual health effects of long-term isolation are largely unknown. The current study investigated the arrhythmic consequences of the COVID-19 lockdown in patients with defibrillators (ICDs) living in the province of Ferrara, Italy. METHODS: Both the arrhythmias and the delivered ICD therapies as notified by the devices were prospectively collected during the lockdown period (P1) and compared to those occurred during the 10 weeks before the lockdown began (P2) and during the same period in 2019 (P3). Changes in outcome over the three study periods were evaluated for significance using McNemar's test. RESULTS: A total of 413 patients were included in the analysis. No differences were found concerning either arrhythmias or shocks or anti-tachycardia pacing. Only the number of patients experiencing non-sustained ventricular tachycardias (NSVTs) during P1 significantly decreased as compared to P2 (p = 0.026) and P3 (p = 0.009). The subgroup analysis showed a significant decrease in NSVTs during P1 for men (vs. P2, p = 0.014; vs. P3, p = 0.040) and younger patients (vs. P2, p = 0.002; vs. P3, p = 0.040) and for ischemic etiology (vs. P2, p = 0.003). No arrhythmic deaths occurred during P1. CONCLUSIONS: The complete nationwide lockdown, as declared by the Italian government during the first COVID-19 pandemic peak, did not impact on the incidence of arrhythmias in an urban cohort of patients with ICDs.


Asunto(s)
Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , COVID-19/epidemiología , Desfibriladores Implantables , Neumonía Viral/epidemiología , Anciano , Femenino , Humanos , Italia/epidemiología , Masculino , Pandemias , Distanciamiento Físico , Neumonía Viral/virología , Estudios Prospectivos , SARS-CoV-2
12.
Int J Mol Sci ; 22(12)2021 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-34204499

RESUMEN

BACKGROUND: Brugada syndrome (BrS) is an autosomal dominantly inherited cardiac disease characterized by "coved type" ST-segment elevation in the right precordial leads, high susceptibility to ventricular arrhythmia and a family history of sudden cardiac death. The SCN5A gene, encoding for the cardiac voltage-gated sodium channel Nav1.5, accounts for ~20-30% of BrS cases and is considered clinically relevant. METHODS: Here, we describe the clinical findings of two Italian families affected by BrS and provide the functional characterization of two novel SCN5A mutations, the missense variant Pro1310Leu and the in-frame insertion Gly1687_Ile1688insGlyArg. RESULTS: Despite being clinically different, both patients have a family history of sudden cardiac death and had history of arrhythmic events. The Pro1310Leu mutation significantly reduced peak sodium current density without affecting channel membrane localization. Changes in the gating properties of expressed Pro1310Leu channel likely account for the loss-of-function phenotype. On the other hand, Gly1687_Ile1688insGlyArg channel, identified in a female patient, yielded a nearly undetectable sodium current. Following mexiletine incubation, the Gly1687_Ile1688insGlyArg channel showed detectable, albeit very small, currents and biophysical properties similar to those of the Nav1.5 wild-type channel. CONCLUSIONS: Overall, our results suggest that the degree of loss-of-function shown by the two Nav1.5 mutant channels correlates with the aggressive clinical phenotype of the two probands. This genotype-phenotype correlation is fundamental to set out appropriate therapeutical intervention.


Asunto(s)
Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Estudios de Asociación Genética , Predisposición Genética a la Enfermedad , Mutación , Canal de Sodio Activado por Voltaje NAV1.5/genética , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Alelos , Sustitución de Aminoácidos , Electrocardiografía , Femenino , Estudios de Asociación Genética/métodos , Genotipo , Humanos , Italia , Masculino , Modelos Biológicos , Modelos Moleculares , Canal de Sodio Activado por Voltaje NAV1.5/química , Canal de Sodio Activado por Voltaje NAV1.5/metabolismo , Linaje , Fenotipo , Conformación Proteica , Transporte de Proteínas
13.
Europace ; 22(4): 558-566, 2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-31821488

RESUMEN

AIMS: The ESC EORP EHRA Atrial Fibrillation (AF) Ablation Long-Term registry was designed to assess management and outcomes of AF catheter ablation procedures in Europe. To investigate the current ablation approaches and their outcomes for patients with paroxymal AF (PAF) and non-PAF in Europe. METHODS AND RESULTS: Data from index ablations were collected in 27 European countries at 104 centres in a prospective fashion. Pre-procedural, procedural, and 1-year follow-up data were captured on a web-based electronic case record form. Data on the ablation procedure were available for 3446 patients. Of these, 2513 patients and 933 patients underwent pulmonary vein isolation (PVI) or PVI plus (PVIplus) additional ablation, respectively. The ablation strategy was limited to PVI in 81% and 56% of patients in the PAF and non-PAF group, respectively (P < 0.001). In the non-PAF group, left atrial linear ablation and ablation of complex fragmented atrial electrograms were more commonly performed. Arrhythmias recurrence after PVI was 29% and 39% in the PAF and non-PAF group, respectively (P < 0.001) and 42% after PVIplus in both groups. Atrial fibrillation related hospital admissions were more common in the PVIplus group (20% vs. 14%). A very low procedural complication rate was observed. No relevant differences were observed with regard to repeat ablation (PVI 9% and PVIplus 11%). CONCLUSION: In patients with PAF and non-PAF, the ablation strategies of PVI and PVIplus led to similar arrhythmia-free survival rates after 1 year. A considerable hospital readmission rate was noted.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Europa (Continente) , Humanos , Estudios Prospectivos , Venas Pulmonares/cirugía , Recurrencia , Sistema de Registros , Resultado del Tratamiento
14.
Europace ; 22(12): 1848-1854, 2020 12 23.
Artículo en Inglés | MEDLINE | ID: mdl-32944767

RESUMEN

AIMS: Our aim was to describe the electrocardiographic features of critical COVID-19 patients. METHODS AND RESULTS: We carried out a multicentric, cross-sectional, retrospective analysis of 431 consecutive COVID-19 patients hospitalized between 10 March and 14 April 2020 who died or were treated with invasive mechanical ventilation. This project is registered on ClinicalTrials.gov (identifier: NCT04367129). Standard ECG was recorded at hospital admission. ECG was abnormal in 93% of the patients. Atrial fibrillation/flutter was detected in 22% of the patients. ECG signs suggesting acute right ventricular pressure overload (RVPO) were detected in 30% of the patients. In particular, 43 (10%) patients had the S1Q3T3 pattern, 38 (9%) had incomplete right bundle branch block (RBBB), and 49 (11%) had complete RBBB. ECG signs of acute RVPO were not statistically different between patients with (n = 104) or without (n=327) invasive mechanical ventilation during ECG recording (36% vs. 28%, P = 0.10). Non-specific repolarization abnormalities and low QRS voltage in peripheral leads were present in 176 (41%) and 23 (5%), respectively. In four patients showing ST-segment elevation, acute myocardial infarction was confirmed with coronary angiography. No ST-T abnormalities suggestive of acute myocarditis were detected. In the subgroup of 110 patients where high-sensitivity troponin I was available, ECG features were not statistically different when stratified for above or below the 5 times upper reference limit value. CONCLUSIONS: The ECG is abnormal in almost all critically ill COVID-19 patients and shows a large spectrum of abnormalities, with signs of acute RVPO in 30% of the patients. Rapid and simple identification of these cases with ECG at hospital admission can facilitate classification of the patients and provide pathophysiological insights.


Asunto(s)
Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/virología , COVID-19/complicaciones , Enfermedad Crítica , Electrocardiografía , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , COVID-19/epidemiología , Estudios Transversales , Femenino , Hospitalización/estadística & datos numéricos , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Pandemias , Respiración Artificial , Estudios Retrospectivos , SARS-CoV-2
15.
Curr Heart Fail Rep ; 17(6): 384-396, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32979151

RESUMEN

PURPOSE OF REVIEW: The aim of this review is to summarily explain what LV synchrony, coordination, myocardial work, and flow dynamics are, trying to clarify their advantages and limitations in the treatment of heart failure patients undergoing or with implanted cardiac resynchronization therapy (CRT). RECENT FINDINGS: CRT is an established treatment for patients with heart failure and left ventricular systolic dysfunction. In the current guidelines, CRT implant indications rely only on electrical dyssynchrony, but in the last years, many aspects of cardiac mechanics (including contractile synchrony, coordination, propagation, and myocardial work) and flow dynamics have been studied using echocardiographic techniques to better characterize patients undergoing or with implanted CRT. However, the concepts, limits, and potential applications of all these echocardiographic evaluations are unclear to most clinicians. The use of left ventricular dyssynchrony and discoordination indices may help to identify those significant mechanical alterations whose correction may increase the probability of a favorable CRT response. Assessment of myocardial work and intracardiac flow dynamics may overcome some limitations of the conventional evaluation of cardiac mechanics but more investigations are needed before extensive clinical application.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Terapia de Resincronización Cardíaca/métodos , Ecocardiografía/métodos , Insuficiencia Cardíaca/diagnóstico , Ventrículos Cardíacos/diagnóstico por imagen , Función Ventricular Izquierda/fisiología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/fisiopatología , Humanos
16.
Europace ; 21(10): 1527-1536, 2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31209482

RESUMEN

AIMS: The benefit of prolonged implantable cardioverter-defibrillator (ICD)/cardiac resynchronization therapy defibrillator (CRT-D) therapy following device replacement is hindered by clinical and procedure-related adverse events (AEs). Adverse events rate is highest in more complex devices and at upgrades, as per the REPLACE registry experience, but is changing owing to the improvement in device technology and medical care. We aimed at understanding the extent and type of AEs in a contemporary Italian population. METHODS AND RESULTS: Detect long-term complications after ICD replacement (DECODE) was a prospective, single-arm, multicentre cohort study aimed at estimating medium- to long-term AEs in a large population of patients undergoing ICD/cardiac resynchronization defibrillator replacement/upgrade from 2013 to 2015. We prospectively analysed all clinical and device-related AEs at 12-month follow-up (FU) of 983 consecutive patients (median age 71 years, 76% male, 55% ischaemic, 47% CRT-D) followed for 353 ± 49 days. Seven percent of the patients died (60.6% for cardiovascular reasons), whereas 104 AEs occurred; 43 (4.4%) patients needed at least one surgical action to treat the AE. Adverse events rates were 3.3/100 years lead-related, 3.4/100 years bleedings, and 1.6/100 years infective. The primary endpoint was predicted by hospitalization in the month prior to the procedure [hazard ratio (HR) = 2.23, 1.16-4.29; 0.0169] and by upgrade (HR = 1.75, 1.02-2.99, 0.0441). One hundred and twelve (11.4%) patients met the combined endpoint of death from any cause, cardiac implantable electronic device (CIED)-related infection, and surgical action/hospitalization required to treat the AE. Hospitalization within 30 days prior to the procedure (HR = 2.07, 1.13-3.81; 0.0199), anticoagulation (HR = 1.97, 1.26-3.07; 0.003), and ischaemic cardiomyopathy (HR = 1.67, 95% confidence interval 1.06-2.63; P = 0.0276) were associated with the combined endpoint during FU. CONCLUSIONS: Adverse events following CIED replacement/upgrade are lower than previously reported, possibly owing to improved patients care. Hospitalization in the month prior to the procedure, upgrade, and clinical profile (anticoagulation, ischaemic cardiomyopathy) hint to increased risk, suggesting an individualized planning of the procedure to minimize overall AEs. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/ Identifier: NCT02076789.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Sistema de Registros , Anciano , Muerte Súbita Cardíaca/epidemiología , Remoción de Dispositivos , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Italia/epidemiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Resultado del Tratamiento
17.
Echocardiography ; 36(10): 1919-1929, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31513321

RESUMEN

In the past years, assessment of cardiac function has become possible through the analysis of intracardiac flow dynamics, performed noninvasively using phase-contrast cardiac magnetic resonance and contrast and noncontrast ultrasound techniques. From 2013 to 2019, 9 echocardiographic investigations have considered 215 patients with cardiac resynchronization therapy (CRT) as a model for assessing flow dynamics within the left ventricle. Preliminary results have been reported about the acute hemodynamic effects of CRT and programming of the CRT device, showing the potential of an approach based on analysis of intracardiac flows. At present, there are only scarce data on the capability of intracardiac flow dynamics to predict LV remodeling after CRT and no information on clinical outcome prediction. Future investigations should be aimed at clarifying the mechanisms and impact of maladaptive intracardiac vortex dynamics on progressive LV remodeling as well as the prognostic meaning of implanted CRT device based on cardiac flow analysis.


Asunto(s)
Terapia de Resincronización Cardíaca , Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Hemodinámica/fisiología , Función Ventricular Izquierda/fisiología , Remodelación Ventricular/fisiología , Humanos
18.
Europace ; 20(9): 1475-1483, 2018 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-29186401

RESUMEN

Aim: Ventricular tachycardia (VT)/ventricular fibrillation (VF) occurrence after cardiac resynchronization therapy-defibrillator (CRT-D) replacement is unknown; hence, there is no practical guideline to recommend either CRT-D or CRT-pacemaker at the time of device replacement. We observed the 1-year VT/VF occurrence after CRT-D replacement in a subanalysis of the Detect Long-term Complications after ICD Replacement (DECODE) registry. Methods and results: A total of 332 consecutive patients who had undergone CRT-D replacement from 2013 to 2015 were enrolled in 36 Italian centres. The primary endpoint was the number of patients with any appropriate implantable cardioverter-defibrillator (ICD) interventions during 12-month follow-up. The secondary endpoint comprised death from any cause and appropriate ICD interventions. At replacement, 214 (64.5%) patients had a left ventricular ejection fraction ≤ 35% and 138 (41.6%) patients had a secondary prevention indication for ICD. Seventy (21.1%) patients had no longer indication to ICD therapy. During a median follow-up period of 406.5 (362-533) days, VT/VF requiring therapy delivery occurred in 57 (17%) patients, specifically in 7% of those who no longer had an ICD indication. On multivariate analysis, number of criteria for ICD replacement independently predicted appropriate ICD intervention during follow-up [hazard ratio (HR) = 1.62, 95% confidence interval (CI) 1.07-2.46; log-rank P = 0.02]. The combined endpoint of death from any cause or appropriate ICD therapy occurred in 76 (23%) patients. Only NYHA class remained associated with this combined endpoint (HR = 1.97, 95% CI 1.23-3.14; P = 0.005). Conclusions: The DECODE registry showed the 'real-world' experience of CRT-D recipients approaching device replacement, in which 7% of patients who no longer had an indication for ICD therapy experienced appropriate ICD interventions.


Asunto(s)
Fibrilación Atrial/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Implantación de Prótesis , Taquicardia Ventricular/epidemiología , Fibrilación Ventricular/epidemiología , Anciano , Terapia de Resincronización Cardíaca , Remoción de Dispositivos , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Modelos de Riesgos Proporcionales , Volumen Sistólico
19.
Echocardiography ; 35(5): 707-715, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29719067

RESUMEN

Cardiac resynchronization therapy (CRT) is an established treatment for patients with heart failure and left ventricular systolic dysfunction. For many years, cardiac mechanical dyssynchrony assessed by echocardiography has been considered as a key evaluation to characterize CRT candidates and predict CRT response. In current guidelines, however, CRT implant indications rely only on electrical dyssynchrony. The aim of this article was to clarify whether and how the evaluation of cardiac mechanical dyssynchrony should be performed today by echocardiography.


Asunto(s)
Terapia de Resincronización Cardíaca , Ecocardiografía/métodos , Insuficiencia Cardíaca/diagnóstico , Disfunción Ventricular Izquierda/diagnóstico , Humanos
20.
Heart Fail Rev ; 22(6): 699-722, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28714039

RESUMEN

Cardiac resynchronization therapy (CRT) is an established treatment for patients with heart failure and left ventricular systolic dysfunction. Patients are usually assessed by echocardiography, which provides a number of anatomical and functional information used for cardiac dyssynchrony assessment, prognostic stratification, identification of the optimal site of pacing in the left ventricle, optimization of the CRT device, and patient follow-up. Compared to other cardiac imaging techniques, echocardiography has the advantage to be non-invasive, repeatable, and safe, without exposure to ionizing radiation or nefrotoxic contrast. In this article, we review current evidence about the role of echocardiography before, during, and after the implantation of a CRT device.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Ecocardiografía , Insuficiencia Cardíaca , Ventrículos Cardíacos/diagnóstico por imagen , Función Ventricular Izquierda/fisiología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/fisiopatología , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA