Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Clin Rheumatol ; 20(6): 306-9, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25160012

RESUMEN

BACKGROUND: An increasing role of dual-energy computed tomography (DECT) scan in tophaceous gout assessment is recognized, whereas its role in asymptomatic hyperuricemia is unknown. OBJECTIVE: The objective of this study was to assess the prevalence of joint and renal monosodium urate deposits by DECT in asymptomatic hyperuricemia. METHODS: Among a renal transplant population with at least 1 year of follow-up, we included 27 patients with sustained hyperuricemia and 11 with normal serum uric acid (SUA) levels. We excluded patients with gout or history of monoarthritis or oligoarthritis. We registered demographic data, drugs, hyperuricemia onset, comorbidities, renal function, and SUA. We used a 128-slice dual-source CT system, and the acquisition protocol included the pelvis and imaging of elbows, wrists, hands, knees, ankles, and feet. The reading process was performed by 2 radiologists. RESULTS: The mean age was 43.7 ± 12 years, 57.8% were males, and median follow-up was 7 years. Hyperuricemia presented after a median time of 0.61 years after transplantation and had persisted for a median of 3.2 years (0.5-16.8 years). For the hyperuricemic group, the median SUA at the DECT scan and the maximum SUA levels were 7.9 and 8.9 mg/dL, respectively. Groups were similar in most of the clinical variables. We did not find any articular or renal deposit; conversely, we demonstrated a quadriceps tendon deposition in 1 patient with hyperuricemia (prevalence of 0.03%; 95% confidence interval, 0.006%-0.17%). CONCLUSIONS: In these patients with asymptomatic hyperuricemia, the prevalence of monosodium urate deposition assessed by DECT was low; however, larger studies need to be performed for further validation.


Asunto(s)
Hiperuricemia/metabolismo , Articulaciones/metabolismo , Trasplante de Riñón , Riñón/metabolismo , Ácido Úrico/metabolismo , Adulto , Artrografía , Femenino , Estudios de Seguimiento , Gota/diagnóstico por imagen , Gota/epidemiología , Gota/metabolismo , Humanos , Hiperuricemia/diagnóstico por imagen , Hiperuricemia/epidemiología , Riñón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Proyectos Piloto , Prevalencia , Tomografía Computarizada Espiral
2.
J Invasive Cardiol ; 36(8)2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38489568

RESUMEN

OBJECTIVES: Little is known about valve hemodynamic performance during the Evolut and Neo deployment course. We aimed to evaluate transvalvular mean and peak-to-peak gradients over several intraprocedural timepoints during TAVR with Evolut PRO+ (Medtronic) and Neo (Boston Scientific) systems. METHODS: This was single-center pilot sub-study from the SavvyWire EFficacy and SafEty in Transcatheter Aortic Valve Implantation Procedures (SAFE-TAVI) trial. Participants received either the Evolut PRO+ or Neo for native valve severe aortic stenosis and the SavvyWire (OpSens Medical) was used for device delivery, pacing, and continuous left ventricular and aortic pressure measurements. For the Evolut, evaluation was done for baseline, two-thirds of valve deployment (still recapturable), 90% of valve deployment (no longer recapturable), and post-deployment hemodynamics. For the Neo, analysis was done at baseline, after the first step (top-crown deployment), and at final status. RESULTS: Nineteen patients were included (Evolut = 15; Neo = 4). There were no statistically significant changes in peak-to-peak gradients (44 mm Hg [IQR:33-69] vs 43 mm Hg [IQR:26-62], P = .41) between baseline and two-thirds of valve deployment in the Evolut patients. There was a significant decrease in mean (40 mm Hg [IQR:32-54] vs 14 mm Hg [IQR:10-18], P less than .001) and peak-to-peak (43 mmHg [IQRS:26-62] vs 9 mm Hg [IQR:8-13], P less than .001) transvalvular gradients between two-thirds and 90% of valve deployment for Evolut. Neo patients exhibited a decrease in transvalvular gradients after top-crown deployment (42.5 mm Hg baseline vs 13 mm Hg). CONCLUSIONS: Transvalvular gradients did not vary between the point of "no-recapture" compared to baseline values in patients receiving the Evolut, whereas a significant reduction in transvalvular gradients was observed when the valve was deployed at 90% and fully deployed. The Neo valve was slightly obstructive after the first step of deployment.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Hemodinámica , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Masculino , Femenino , Hemodinámica/fisiología , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Anciano de 80 o más Años , Resultado del Tratamiento , Proyectos Piloto , Anciano , Estudios de Seguimiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA