Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Heart Surg Forum ; 24(2): E261-E266, 2021 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-33798046

RESUMEN

BACKGROUND: Tricuspid annuloplasty is the most common surgical approach to correct tricuspid regurgitation (TR). In some patients, however, anterior leaflet patch augmentation may be necessary to optimize tricuspid competence. We reviewed our center cohort over the midterm and long term. METHODS: From January 2013 to August 2018, 424 tricuspid valve procedures were performed, of which 420 were repairs and 4 were replacements. Indications were either isolated severe TR or moderate or greater TR, concomitant with other surgery. In the repair cohort, we identified those that had a patch augmentation, and the database was interrogated for preoperative characteristics. The resulting patients had outpatient assessment (clinical and echocardiography) at 6 weeks and at a later interval. Additionally, a comparison was made between those who had good and poor results (moderate or greater TR or cardiac death). RESULTS: In the repair cohort, 19 patients underwent complex tricuspid valve repair with CorMatrix anterior leaflet augmentation. Preoperative characteristics were as follows: age, 65.5 ± 13.5 years; New York Heart Association (NYHA) class, 3.5 ± 0.5; left ventricular ejection fraction, 48.3% ± 5.9%; tricuspid annular plane systolic excursion, 17.1 ± 3.7 mm; right ventricle (good, mild, moderate, poor), 10, 5, 4, 0; annulus size, 40.9 ± 6.9 mm; mean tethering distance, 1.00 ± 0.3 cm; and mean tethering area, 1.53 ± 1.16 cm2. Mean follow-up was 2.1 ± 1.9 years, and survival at 2 years was 73.8%. There were 2 in-hospital deaths. Mean NYHA class was 1.0 ± 0.5 (6 weeks) and 1.5 ± 0.6 (later follow-up); mean residual TR grade was 0.5 ± 0.6 (6 weeks) and 1.3 ± 1.4 (follow-up). Ten of 13 survivors had a good result at last follow-up (TR 0 to 1). We compared the preoperative and operative data of this group versus those with poor results (TR >1 or cardiac mortality). Significant univariate predictors of poor results were larger preoperative tethering area (1.18 ± 0.43 versus 2.4 ± 1.5 cm2; P = .02), longer tethering distance (0.87 ± 0.21 versus 1.2 ± 0.19 cm; P = .007), or the presence of mild or greater TR at 6 weeks (0.2 ± 0.4 vs 1.25 ± 0.5; P = .03). CONCLUSIONS: CorMatrix anterior leaflet augmentation produces successful, stable repair in the majority of this complex population. The presence of even mild TR at 6 weeks' follow-up predicts a poor result. When the tethering area or the tethering distance is significantly high, replacement is probably a better option.


Asunto(s)
Anuloplastia de la Válvula Cardíaca/métodos , Volumen Sistólico/fisiología , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Función Ventricular Izquierda/fisiología , Anciano , Ecocardiografía/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA