Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Br J Haematol ; 184(6): 949-956, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30515751

RESUMEN

To assess efficacy of radioimmunotherapy (RIT) in follicular lymphoma, data from 281 patients collected in the RIT Network, with a median follow-up of 8·2 years after RIT were analysed. RIT was given at first line in 18·5% and at relapse in 81·5%. Following first line therapy, 76·9% achieved complete remission (CR), 9·6% partial remission (PR), 1·9% stable disease (SD) and 1·9% had progressive disease (PD); response was not documented in 9·7%. At relapse, the rate of CR was 48·5% and that of PR was 16·6%, SD 2·6% and PD 10·5%; response was not documented in 21·8%. After median follow-up of 8·2 years, median progression-free survival (PFS) for all was 2·54 years, median overall survival (OS) was not reached. Median PFS and OS (both not reached) were significantly better in first line, compared to RIT at relapse (PFS, 2·11 years; OS, 10·8 years; P = 0·0037 and P = 0·0021, respectively). Overall 8-year PFS was 33·9%, 53·6% for first line and 29·6% for relapsed individuals. Overall 8-year OS was 58·8%, 78·1% for first line and 54·5% for relapsed patients. Thirty-five patients (12·5%) developed secondary malignancy and 16 patients (5·7%) experienced transformation into aggressive lymphoma. RIT is a safe and effective treatment option for follicular lymphoma, both at front line and relapse with an 8-year PFS of 53·6% and 29·6%, respectively.


Asunto(s)
Linfoma Folicular/radioterapia , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia , Radioinmunoterapia , Sistema de Registros , Factores de Tiempo , Resultado del Tratamiento
2.
Hematol Oncol ; 35(4): 576-583, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27677906

RESUMEN

Standard conditioning regimens for autologous stem cell transplantation (ASCT) are often not tolerated by elderly patients, on one hand. Single high-dose melphalan, on the other hand, has been shown to be safe and active as a pretransplant preparative regimen in elderly patients. Y90 -Ibritumomab tiuxetan (Y90 -IT) is well tolerated and feasible in the transplantation setting. We therefore investigated the combination of high-dose melphalan and Y90 -IT as a conditioning regimen for patients ≥65 years of age. Patients with relapsed or resistant CD20-positive lymphoma in remission after salvage chemotherapy could be enrolled. High-dose therapy consisted of standard dose Y90 -IT (0.4-mCi/kg body weight) followed by melphalan at escalating doses (100, 140, 170 and 200 mg/m2 ) and ASCT. The primary objective was to identify the maximum tolerated dose; secondary end points were complete response (CR) rate 100 days after transplantation and toxicity. Twenty patients (median age 72 years) were included. No DLT occurred at any dose level. Thirteen patients completed the treatment, 11 were evaluable for response. Seven patients did not complete treatment because of mobilization failure (n = 3), progressive disease (n = 2), worsening of cardiac function (n = 1), and grade 3 dyspnea (n = 1). Seven patients achieved a CR/complete remission/unconfirmed (CRu) and 2 had stable disease. Five out of 7 responding patients were still alive more than 3 years after transplantation. The 2 patients with SD had a long-term survival of 3 and 5 years, respectively. Nonhematological grade 3 or higher treatment related adverse events (AEs) were infection (n = 6), including 2 cases of febrile neutropenia, diarrhea (n = 3), mucositis, anorexia, viral hepatitis, hypokalemia, dehydration, and multiorgan failure (n = 1 for each). The combination of Y90 -IT and high-dose melphalan is feasible before ASCT for elderly patients, with promising activity and manageable toxicity.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Trasplante de Células Madre Hematopoyéticas , Linfoma/patología , Linfoma/terapia , Acondicionamiento Pretrasplante , Factores de Edad , Anciano , Anciano de 80 o más Años , Anticuerpos Monoclonales/administración & dosificación , Protocolos de Quimioterapia Combinada Antineoplásica/efectos adversos , Resistencia a Antineoplásicos , Femenino , Trasplante de Células Madre Hematopoyéticas/efectos adversos , Humanos , Linfoma/mortalidad , Masculino , Melfalán/administración & dosificación , Clasificación del Tumor , Recurrencia , Retratamiento , Factores de Tiempo , Acondicionamiento Pretrasplante/efectos adversos , Acondicionamiento Pretrasplante/métodos , Trasplante Autólogo , Resultado del Tratamiento , Radioisótopos de Itrio
3.
Phys Med ; 117: 103188, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38042710

RESUMEN

Radionuclide therapy, also called molecular radiotherapy (MRT), has come of age, with several novel radiopharmaceuticals being approved for clinical use or under development in the last decade. External beam radiotherapy (EBRT) is a well-established treatment modality, with about half of all oncologic patients expected to receive at least one external radiation treatment over their disease course. The efficacy and the toxicity of both types of treatment rely on the interaction of radiation with biological tissues. Dosimetry played a fundamental role in the scientific and technological evolution of EBRT, and absorbed doses to the target and to the organs at risk are calculated on a routine basis. In contrast, in MRT the usefulness of internal dosimetry has long been questioned, and a structured path to include absorbed dose calculation is missing. However, following a similar route of development as EBRT, MRT treatments could probably be optimized in a significant proportion of patients, likely based on dosimetry and radiobiology. In the present paper we describe the differences and the similarities between internal and external-beam dosimetry in the context of radiation treatments, and we retrace the main stages of their development over the last decades.


Asunto(s)
Tortugas , Animales , Humanos , Radiometría , Radiofármacos/uso terapéutico , Dosificación Radioterapéutica
4.
Eur J Nucl Med Mol Imaging ; 39(6): 1037-47, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22398957

RESUMEN

PURPOSE: Quantification of myocardial blood flow (MBF) with generator-produced (82)Rb is an attractive alternative for centres without an on-site cyclotron. Our aim was to validate (82)Rb-measured MBF in relation to that measured using (15)O-water, as a tracer 100% of which can be extracted from the circulation even at high flow rates, in healthy control subject and patients with mild coronary artery disease (CAD). METHODS: MBF was measured at rest and during adenosine-induced hyperaemia with (82)Rb and (15)O-water PET in 33 participants (22 control subjects, aged 30 ± 13 years; 11 CAD patients without transmural infarction, aged 60 ± 13 years). A one-tissue compartment (82)Rb model with ventricular spillover correction was used. The (82)Rb flow-dependent extraction rate was derived from (15)O-water measurements in a subset of 11 control subjects. Myocardial flow reserve (MFR) was defined as the hyperaemic/rest MBF. Pearson's correlation r, Bland-Altman 95% limits of agreement (LoA), and Lin's concordance correlation ρ (c) (measuring both precision and accuracy) were used. RESULTS: Over the entire MBF range (0.66-4.7 ml/min/g), concordance was excellent for MBF (r = 0.90, [(82)Rb-(15)O-water] mean difference ± SD = 0.04 ± 0.66 ml/min/g, LoA = -1.26 to 1.33 ml/min/g, ρ(c) = 0.88) and MFR (range 1.79-5.81, r = 0.83, mean difference = 0.14 ± 0.58, LoA = -0.99 to 1.28, ρ(c) = 0.82). Hyperaemic MBF was reduced in CAD patients compared with the subset of 11 control subjects (2.53 ± 0.74 vs. 3.62 ± 0.68 ml/min/g, p = 0.002, for (15)O-water; 2.53 ± 1.01 vs. 3.82 ± 1.21 ml/min/g, p = 0.013, for (82)Rb) and this was paralleled by a lower MFR (2.65 ± 0.62 vs. 3.79 ± 0.98, p = 0.004, for (15)O-water; 2.85 ± 0.91 vs. 3.88 ± 0.91, p = 0.012, for (82)Rb). Myocardial perfusion was homogeneous in 1,114 of 1,122 segments (99.3%) and there were no differences in MBF among the coronary artery territories (p > 0.31). CONCLUSION: Quantification of MBF with (82)Rb with a newly derived correction for the nonlinear extraction function was validated against MBF measured using (15)O-water in control subjects and patients with mild CAD, where it was found to be accurate at high flow rates. (82)Rb-derived MBF estimates seem robust for clinical research, advancing a step further towards its implementation in clinical routine.


Asunto(s)
Circulación Coronaria , Tomografía de Emisión de Positrones/métodos , Radioisótopos de Rubidio , Agua , Adulto , Estudios de Casos y Controles , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Imagen de Perfusión Miocárdica , Radioisótopos de Oxígeno , Reproducibilidad de los Resultados
5.
Eur J Nucl Med Mol Imaging ; 39(12): 1868-75, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22940856

RESUMEN

PURPOSE: The biokinetics and dosimetry of (111)In-DOTA-NOC-ATE (NOCATE), a high-affinity ligand of SSTR-2 and SSTR-5, and (111)In-DTPA-octreotide (Octreoscan™, OCTREO) were compared in the same patients. METHODS: Seventeen patients (10 men, 7 women; mean age 60 years), referred for an OCTREO scan for imaging of a neuroendocrine tumour (15), thymoma (1) or medullary thyroid carcinoma (1), agreed to undergo a second study with NOCATE. Whole-body anterior-posterior scans were recorded 0.5 (100 % reference scan), 4, 24 and 48 h (17 patients) and 120 h (5 patients) after injection. In 16 patients the OCTREO scan (178 ± 15 MBq) was performed 16 ± 5 days before the NOCATE scan (108 ± 14 MBq) with identical timing; 1 patient had the NOCATE scan before the OCTREO scan. Blood samples were obtained from 14 patients 5 min to 48 h after injection. Activities expressed as percent of the initial (reference) activity in the whole body, lung, kidney, liver, spleen and blood were fitted to biexponential or single exponential functions. Dosimetry was performed using OLINDA/EXM. RESULTS: Initial whole-body, lung and kidney activities were similar, but retention of NOCATE was higher than that of OCTREO. Liver and spleen uptakes of NOCATE were higher from the start (p < 0.001) and remained so over time. Whole-body activity showed similar α and ß half-lives, but the ß fraction of NOCATE was double that of OCTREO. Blood T (1/2)ß for NOCATE was longer (19 vs. 6 h). As a result, the effective dose of NOCATE (105 µSv/MBq) exceeded that of OCTREO (52 µSv/MBq), and the latter result was similar to the ICRP 106 value of 54 µSv/MBq. Differential activity measurement in blood cells and plasma showed an average of <5 % of NOCATE and OCTREO attached to globular blood components. CONCLUSION: NOCATE showed a slower clearance from normal tissues and its effective dose was roughly double that of OCTREO.


Asunto(s)
Tumores Neuroendocrinos/diagnóstico por imagen , Octreótido/análogos & derivados , Compuestos Organometálicos/farmacocinética , Ácido Pentético/análogos & derivados , Radiofármacos/farmacocinética , Timoma/diagnóstico por imagen , Neoplasias del Timo/diagnóstico por imagen , Neoplasias de la Tiroides/diagnóstico por imagen , Adulto , Anciano , Carcinoma Neuroendocrino , Femenino , Humanos , Masculino , Persona de Mediana Edad , Octreótido/farmacocinética , Ácido Pentético/farmacocinética , Radiometría , Cintigrafía , Distribución Tisular
6.
Eur J Nucl Med Mol Imaging ; 37(12): 2436-46, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20644928

RESUMEN

The aim of this document is to provide general information about mIBG scintigraphy in cancer patients. The guidelines describe the mIBG scintigraphy protocol currently used in clinical routine, but do not include all existing procedures for neuroendocrine tumours. The guidelines should therefore not be taken as exclusive of other nuclear medicine modalities that can be used to obtain comparable results. It is important to remember that the resources and facilities available for patient care may vary from one country to another and from one medical institution to another. The present guidelines have been prepared for nuclear medicine physicians and intend to offer assistance in optimizing the diagnostic information that can currently be obtained from mIBG scintigraphy. The corresponding guidelines of the Society of Nuclear Medicine (SNM) and the Dosimetry, Therapy and Paediatric Committee of the EANM have been taken into consideration, and partially integrated into this text. The same has been done with the most relevant literature on this topic, and the final result has been discussed within a group of distinguished experts.


Asunto(s)
3-Yodobencilguanidina , Oncología Médica/normas , Neoplasias/diagnóstico por imagen , Medicina Nuclear/normas , Guías de Práctica Clínica como Asunto , Cintigrafía/normas , Humanos , Radiofármacos
7.
Oncologist ; 14 Suppl 2: 17-29, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19819921

RESUMEN

Non-Hodgkin's lymphoma (NHL) comprises both indolent forms, including follicular lymphoma (FL) and marginal zone lymphoma (MZL), and aggressive forms, including diffuse large B-cell lymphoma (DLBCL) and mantle cell lymphoma (MCL). FL and DLBCL are the most common subtypes of indolent and aggressive NHL, respectively. Although these lymphomas exhibit different clinical behaviors and outcomes, the prognosis is negatively affected in both DLBCL and FL by the lack of a complete response (CR) with standard treatment options. The aim of therapy should therefore be achievement of a CR, which is not only associated with longer progression-free survival (PFS) and overall survival times, but is also a prerequisite for a cure, particularly in DLBCL. Consolidation treatment with radioimmunotherapy (RIT) is an innovative treatment approach to increase CR rates. Phase II studies have indicated promising results with yttrium-90 ((90)Y)-ibritumomab tiuxetan and iodine-131 ((131)I)-tositumomab as consolidation following induction therapy for previously untreated patients with advanced FL. More recently, investigators reported a marked increase in CR rates and significant improvements in PFS using standard chemotherapy regimens followed by (90)Y-ibritumomab tiuxetan in a phase III randomized trial in patients with previously untreated FL. Data also suggest that RIT may play a role in the treatment of high-risk DLBCL, with encouraging PFS results from a phase II trial of (90)Y-ibritumomab tiuxetan consolidation following induction with rituximab plus chemotherapy in elderly patients with previously untreated DLBCL. With the higher CR rates and longer PFS times observed in patients with FL and DLBCL, as well as encouraging early data from MZL and MCL consolidation trials, RIT appears to have an important role in the treatment of patients with NHL.


Asunto(s)
Anticuerpos Monoclonales/uso terapéutico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Inmunotoxinas/uso terapéutico , Linfoma no Hodgkin/tratamiento farmacológico , Linfoma no Hodgkin/radioterapia , Radioisótopos de Itrio/uso terapéutico , Terapia Combinada , Supervivencia sin Enfermedad , Humanos , Linfoma no Hodgkin/patología , Radioinmunoterapia/métodos
9.
J Nucl Med ; 48(10): 1607-13, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17873127

RESUMEN

UNLABELLED: In sentinel node (SN) biopsy, an interval SN is defined as a lymph node or group of lymph nodes located between the primary melanoma and an anatomically well-defined lymph node group directly draining the skin. As shown in previous reports, these interval SNs seem to be at the same metastatic risk as are SNs in the usual, classic areas. This study aimed to review the incidence, lymphatic anatomy, and metastatic risk of interval SNs. METHODS: SN biopsy was performed at a tertiary center by a single surgical team on a cohort of 402 consecutive patients with primary melanoma. The triple technique of localization was used-that is, lymphoscintigraphy, blue dye, and gamma-probe. Otolaryngologic melanoma and mucosal melanoma were excluded from this analysis. SNs were examined by serial sectioning and immunohistochemistry. All patients with metastatic SNs were recommended to undergo a radical selective lymph node dissection. RESULTS: The primary locations of the melanomas included the trunk (188), an upper limb (67), or a lower limb (147). Overall, 97 (24.1%) of the 402 SNs were metastatic. Interval SNs were observed in 18 patients, in all but 2 of whom classic SNs were also found. The location of the primary was truncal in 11 (61%) of the 18, upper limb in 5, and lower limb in 2. One patient with a dorsal melanoma had drainage exclusively in a cervicoscapular area that was shown on removal to contain not lymph node tissue but only a blue lymph channel without tumor cells. Apart from the interval SN, 13 patients had 1 classic SN area and 3 patients 2 classic SN areas. Of the 18 patients, 2 had at least 1 metastatic interval SN and 2 had a classic SN that was metastatic; overall, 4 (22.2%) of 18 patients were node-positive. CONCLUSION: We found that 2 of 18 interval SNs were metastatic: This study showed that preoperative lymphoscintigraphy must review all known lymphatic areas in order to exclude an interval SN.


Asunto(s)
Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Melanoma/diagnóstico , Melanoma/secundario , Biopsia del Ganglio Linfático Centinela/métodos , Neoplasias Cutáneas/diagnóstico por imagen , Neoplasias Cutáneas/patología , Adulto , Anciano , Femenino , Humanos , Recién Nacido , Metástasis Linfática , Masculino , Persona de Mediana Edad , Cintigrafía , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
Semin Nucl Med ; 47(6): 680-686, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28969766

RESUMEN

An effective management system that integrates quality management is essential for a modern nuclear medicine practice. The Nuclear Medicine and Diagnostic Imaging Section of the International Atomic Energy Agency (IAEA) has the mission of supporting nuclear medicine practice in low- and middle-income countries and of helping them introduce it in their health-care system, when not yet present. The experience gathered over several years has shown diversified levels of development and varying degrees of quality of practice, among others because of limited professional networking and limited or no opportunities for exchange of experiences. Those findings triggered the development of a program named Quality Management Audits in Nuclear Medicine (QUANUM), aimed at improving the standards of NM practice in low- and middle-income countries to internationally accepted standards through the introduction of a culture of quality management and systematic auditing programs. QUANUM takes into account the diversity of nuclear medicine services around the world and multidisciplinary contributions to the practice. Those contributions include clinical, technical, radiopharmaceutical, and medical physics procedures. Aspects of radiation safety and patient protection are also integral to the process. Such an approach ensures consistency in providing safe services of superior quality to patients. The level of conformance is assessed using standards based on publications of the IAEA and the International Commission on Radiological Protection, and guidelines from scientific societies such as Society of Nuclear Medicine and Molecular Imaging (SNMMI) and European Association of Nuclear Medicine (EANM). Following QUANUM guidelines and by means of a specific assessment tool developed by the IAEA, auditors, both internal and external, will be able to evaluate the level of conformance. Nonconformances will then be prioritized and recommendations will be provided during an exit briefing. The same tool could then be applied to assess any improvement after corrective actions are taken. This is the first comprehensive audit program in nuclear medicine that helps evaluate managerial aspects, safety of patients and workers, clinical practice, and radiopharmacy, and, above all, keeps them under control all together, with the intention of continuous improvement.


Asunto(s)
Auditoría Administrativa , Energía Nuclear , Medicina Nuclear/normas , Cintigrafía , Humanos , Agencias Internacionales
11.
Semin Nucl Med ; 47(6): 687-693, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28969767

RESUMEN

The International Atomic Energy Agency has developed a program, named Quality Management Audits in Nuclear Medicine (QUANUM), to help its Member States to check the status of their nuclear medicine practices and their adherence to international reference standards, covering all aspects of nuclear medicine, including quality assurance/quality control of instrumentation, radiopharmacy (further subdivided into levels 1, 2, and 3, according to complexity of work), radiation safety, clinical applications, as well as managerial aspects. The QUANUM program is based on both internal and external audits and, with specifically developed Excel spreadsheets, it helps assess the level of conformance (LoC) to those previously defined quality standards. According to their level of implementation, the level of conformance to requested standards; 0 (absent) up to 4 (full conformance). Items scored 0, 1, and 2 are considered non-conformance; items scored 3 and 4 are considered conformance. To assess results of the audit missions performed worldwide over the last 8 years, a retrospective analysis has been run on reports from a total of 42 audit missions in 39 centers, three of which had been re-audited. The analysis of all audit reports has shown an overall LoC of 73.9 ± 8.3% (mean ± standard deviation), ranging between 56.6% and 87.9%. The highest LoC has been found in the area of clinical services (83.7% for imaging and 87.9% for therapy), whereas the lowest levels have been found for Radiopharmacy Level 2 (56.6%); Computer Systems and Data Handling (66.6%); and Evaluation of the Quality Management System (67.6%). Prioritization of non-conformances produced a total of 1687 recommendations in the final audit report. Depending on the impact on safety and daily clinical activities, they were further classified as critical (requiring immediate action; n = 276; 16% of the total); major (requiring action in relatively short time, typically from 3 to 6 months; n = 604; 36%); whereas the remaining 807 (48%) were classified as minor, that is, to be addressed whenever possible. The greatest proportion of recommendations has been found in the category "Managerial, Organization and Documentation" (26%); "Staff Radiation Protection and Safety" (17.3%); "Radiopharmaceuticals Preparation, Dispensing and Handling" (15.8%); and "Quality Assurance/Quality Control" and "Management of Equipment and Software" (11.4%). The lowest level of recommendations belongs to the item "Human Resources" (4%). The QUANUM program proved applicable to a wide variety of institutions, from small practices to larger centers with PET/CT and cyclotrons. Clinical services rendered to patients showed a good compliance with international standards, whereas issues related to radiation protection of both staff and patients will require a higher degree of attention. This is a relevant feedback for the International Atomic Energy Agency with regard to the effective translation of safety recommendations into routine practice. Training on drafting and application of standard operating procedures should also be considered a priority.


Asunto(s)
Auditoría Administrativa , Energía Nuclear , Medicina Nuclear/normas , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Estudios Retrospectivos
12.
J Nucl Med ; 47(11): 1819-36, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17079816

RESUMEN

This article presents the role of nuclear medicine procedures in investigating renal and parenchymal disease, as well as upper urinary tract abnormalities. More specifically, the use of scintigraphy is described in the exploration of urinary tract dilatation and UTIs, vesicoureteric reflux, renovascular hypertension, and renal transplants. With a low radiation burden and the absence of sedation, these nuclear medicine procedures are easy to perform and can provide clinicians with valuable data on renal perfusion and the function of individual kidneys, as well as on urinary tract dynamics. However, knowledge of limitations and technical pitfalls is essential in understanding the role of scintigraphy among contemporary imaging methods and the unique information it supplies in nephrourology.


Asunto(s)
Medicina Nuclear/tendencias , Pielonefritis/diagnóstico , Renografía por Radioisótopo/métodos , Cintigrafía/métodos , Sistema Urinario/diagnóstico por imagen , Adolescente , Adulto , Anciano , Niño , Preescolar , Femenino , Humanos , Hipertensión Renovascular/diagnóstico , Hipertensión Renovascular/diagnóstico por imagen , Lactante , Trasplante de Riñón/métodos , Masculino , Persona de Mediana Edad , Pielonefritis/diagnóstico por imagen , Renografía por Radioisótopo/instrumentación , Sistema Urinario/patología
14.
EJNMMI Res ; 11(1): 39, 2021 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-33856576
15.
Nuklearmedizin ; 55(5): 203-8, 2016 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-27440125

RESUMEN

AIMS: Vaccination by aerosol inhalation can be used to efficiently deliver antigen against HPV to mucosal tissue, which is particularly useful in developing countries (simplicity of administration, costs, no need for cold chain). For optimal immunological response, vaccine particles should preferentially be delivered to proximal bronchial airways. We aimed at quantifying the deposition of inhaled particles in central airways and peripheral lung, and to assess administration biosafety. Participants, methods: 20 healthy volunteers (13W/7M, aged 24±4y) performed a 10-min free-breathing inhalation of (99m)Tc-stannous chloride colloid aerosol (450 MBq) in a buffer solution without vaccinal particles using an ultrasonic nebulizer (mass median aerodynamic diameter 4.2 µm) and a double mask inside a biosafety cabinet dedicated to assess environmental particle release. SPECT/CT and whole-body planar scintigraphy were acquired to determine whole-body and regional C/P distribution ratio (central-to-peripheral pulmonary deposition counts). Using a phantom, SPECT sensitivity was calibrated to obtain absolute pulmonary activity deposited by inhalation. RESULTS: All participants successfully performed the inhalation that was well tolerated (no change in pulmonary peak expiratory flow rate, p = 0.9). It was environmentally safe (no activity released in the biosafety filter.) 1.3±0.6% (range 0.4-2.6%) of the total nebulizer activity was deposited in the lungs with a C/P distribution ratio of 0.40±0.20 (range 0.15-1.14). CONCLUSION: Quantification and regional distribution of inhaled particles in an aerosolized vaccine model is possible using radioactive particles. This will allow optimizing deposition parameters and determining the particles charge for active-particles vaccination.


Asunto(s)
Aerosoles/farmacocinética , Bronquios/diagnóstico por imagen , Bronquios/metabolismo , Vacunas contra Papillomavirus/administración & dosificación , Vacunas contra Papillomavirus/farmacocinética , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Administración por Inhalación , Adulto , Aerosoles/administración & dosificación , Femenino , Humanos , Marcaje Isotópico , Masculino , Infecciones por Papillomavirus/metabolismo , Infecciones por Papillomavirus/prevención & control , Radiofármacos/farmacocinética , Tecnecio/farmacocinética , Distribución Tisular
17.
Rev Med Suisse ; 1(20): 1335-8, 1341-2, 2005 May 18.
Artículo en Francés | MEDLINE | ID: mdl-15991625

RESUMEN

Initial workup in oncology relies on histology and extensive staging of disease. Assessment of treatment response is also of paramount importance. Functional imaging with PET provides substantially more information than conventional radiology based on anatomic structures. PET applications in oncology are rapidly growing. We review herein the established and investigational indications for PET imaging, and also highlight some of its limitations.


Asunto(s)
Estadificación de Neoplasias , Neoplasias/diagnóstico por imagen , Tomografía de Emisión de Positrones , Humanos
20.
J Nucl Med ; 44(10): 1649-54, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14530481

RESUMEN

UNLABELLED: The study aim was to assess the safety, biodistribution, tissue kinetics, and tumor uptake of the (99m)Tc-labeled neurotensin (NT) analog NT-XI. METHODS: Four patients presenting ductal pancreatic adenocarcinoma were studied with (99m)Tc-NT-XI. Patients were followed by scintigraphy up to 4 h and by continued blood and urinary sampling until surgery 18-22 h after injection. Surgical tissue samples were analyzed for radioactivity uptake and NT receptor expression. RESULTS: No side effects were observed on injection of (99m)Tc-NT-XI. Blood biologic half-lives alpha and beta were 35 min (range, 17-62 min) and 230 min (range, 107-383 min), respectively. Repeated whole-body scintigraphy performed in 2 patients showed a single exponential decrease of whole-body activity with half-lives of 101 and 232 min. Tracer elimination was mainly renal, with 92% and 98% of activity counted in urine in the first 20 h. Kidney, liver, spleen, and bone marrow activity uptake was observed in all patients. Tumor was not visualized in the first 3 patients but could be localized by tomoscintigraphy in the pancreas head region of patient 4. In vitro tissue analysis showed high expression of NT receptor in the tumor of patient 4, correlated with the highest tumor radioactivity uptake and the highest tumor-to-fat radioactivity ratio. In vitro receptor expression was also positive in a second patient having a tumor characterized by very low cellularity; however, the remaining 2 tumors lacked NT receptor expression. CONCLUSION: Injection of (99m)Tc-NT-XI was well tolerated. The in vivo tumor uptake appeared specific as it was observed in the 1 patient with a pancreatic tumor that expressed high amounts of NT receptor. The results are compatible with preclinical animal results and in favor of further development of radiolabeled NT analogs for diagnosis or therapy of cancer.


Asunto(s)
Carcinoma Ductal Pancreático/diagnóstico por imagen , Carcinoma Ductal Pancreático/metabolismo , Neurotensina/farmacocinética , Compuestos de Organotecnecio/farmacocinética , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/metabolismo , Recuento Corporal Total , Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/metabolismo , Adulto , Anciano , Femenino , Semivida , Humanos , Masculino , Tasa de Depuración Metabólica , Persona de Mediana Edad , Neurotensina/análogos & derivados , Valor Predictivo de las Pruebas , Dosis de Radiación , Radiometría , Cintigrafía , Radiofármacos/farmacocinética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA