Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Arthroplasty ; 39(4): 991-996, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38661490

RESUMEN

BACKGROUND: We aimed to compare the clinical outcomes of different head sizes (28-, 32-, and 36- millimeter) in primary total hip arthroplasty (THA) at mean 6 years follow-up (range, 1 to 17.5 years). METHODS: This was a retrospective consecutive study of primary THA at our institution (2003 to 2019). Demographic and surgical data were collected. The primary outcome measures were all-cause revision, revision for dislocation, and all-cause revision excluding dislocation. Continuous descriptive statistics used means, median values, ranges, and 95% confidence intervals, where appropriate. Kaplan-Meier survival curves were used to estimate time to revision. Cox proportional hazard regression analyses were used to compare revision rates between the femoral head size groups. Adjustments were made for age at surgery, sex, primary diagnosis, American Society of Anesthesiologists score, articulation type, and fixation methods. There were 10,104 primary THAs included; median age was 69 years (range, 13 to 101) with 61.5% women. A posterior approach was performed in 71.6%. There were 3,295 hips with 28-mm heads (32.6%), 4,858 (48.1%) with 32-mm heads, and 1,951 (19.3%) with 36-mm heads. RESULTS: Overall rate of revision was 1.7% with the lowest rate recorded for the 36-mm group (2.7 versus 1.3 versus 1.1%). Cox regression analyses showed a decreased risk of all-cause revision for 32 and 36-mm head sizes as compared to 28-mm; this was statistically significant for the 32-mm group (P = .01). Risk of revision for dislocation was significantly reduced in both 32-mm (P = .03) and 36-mm (P = .03) head sizes. Analysis of all cause revision excluding dislocation showed no significant differences between head sizes. CONCLUSIONS: We found a significantly reduced risk of revision for all causes, but particularly revision for dislocation with larger head sizes. Concerns regarding increased risk of early revision for aseptic loosening, polyethylene wear, or taper corrosion with larger heads appear to be unfounded in this cohort of 10,104 patients with up to 17 years follow-up.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Cabeza Femoral , Prótesis de Cadera , Falla de Prótesis , Reoperación , Humanos , Artroplastia de Reemplazo de Cadera/instrumentación , Femenino , Masculino , Reoperación/estadística & datos numéricos , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Adulto , Cabeza Femoral/cirugía , Anciano de 80 o más Años , Adolescente , Diseño de Prótesis , Adulto Joven , Estudios de Seguimiento , Factores de Riesgo
2.
J Arthroplasty ; 2024 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-38972434

RESUMEN

BACKGROUND: Effective surgical wound management in total knee arthroplasty (TKA) is crucial for optimal healing and patient outcomes. Despite surgical advances, managing wounds to prevent complications remains challenging. This study aimed to identify and address evidence gaps in TKA wound management, including preoperative optimization, intraoperative options, and postoperative complication avoidance. Addressing these issues is vital for patient recovery and surgical success. METHODS: This study used the Delphi method with 20 experienced orthopedic surgeons from Europe and North America. Conducted from April to September 2023, the process involved three stages: an initial electronic survey, a virtual meeting, and a concluding electronic survey. The panel reviewed and reached a consensus on 26 statements about TKA wound management based on a comprehensive literature review. Additionally, the panel aimed to identify critical evidence gaps in wound management practices. RESULTS: The panel achieved consensus on various wound management practices but highlighted significant evidence gaps. Consensus was reached on wound closure methods, including mesh-adhesive dressings, skin glue, staples, barbed sutures, and negative pressure wound therapy. However, further evidence is needed to address the cost-effectiveness of these methods and develop best practices for patient outcomes. Identifying these gaps highlights the need for more research to improve TKA wound care. CONCLUSIONS: Identifying major evidence gaps underscores the need for targeted research in TKA wound management. Addressing these gaps is crucial for developing effective, efficient, and patient-friendly wound care strategies. Future research should focus on comparative effectiveness studies and developing guidelines for emerging technologies. Bridging these gaps could improve patient outcomes, reduce complications, and enhance TKA surgery success.

3.
J Arthroplasty ; 39(6): 1524-1529, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38325531

RESUMEN

BACKGROUND: This modified Delphi study aimed to develop a consensus on optimal wound closure and incision management strategies for total hip arthroplasty (THA). Given the critical nature of wound care and incision management in influencing patient outcomes, this study sought to synthesize evidence-based best practices for wound care in THA procedures. METHODS: An international panel of 20 orthopedic surgeons from Europe, Canada, and the United States evaluated a targeted literature review of 18 statements (14 specific to THA and 4 related to both THA and total knee arthroplasty). There were 3 rounds of anonymous voting per topic using a modified 5-point Likert scale with a predetermined consensus threshold of ≥ 75% agreement necessary for a statement to be accepted. RESULTS: After 3 rounds of voting, consensus was achieved for all 18 statements. Notable recommendations for THA wound management included (1) the use of barbed sutures over non-barbed sutures (shorter closing times and overall cost savings); (2) the use of subcuticular sutures over skin staples (lower risk of superficial infections and higher patient preferences, but longer closing times); (3) the use of mesh-adhesives over silver-impregnated dressings (lower rate of wound complications); (4) for at-risk patients, the use of negative pressure wound therapy over other dressings (lower wound complications and reoperations, as well as fewer dressing changes); and (5) the use of triclosan-coated sutures (lower risk of surgical site infection) over standard sutures. CONCLUSIONS: Through a structured modified Delphi approach, a panel of 20 orthopedic surgeons reached consensus on all 18 statements pertaining to wound closure and incision management in THA. This study provides a foundational framework for establishing evidence-based best practices, aiming to reduce variability in patient outcomes and to enhance the overall quality of care in THA procedures.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Técnica Delphi , Humanos , Consenso , Infección de la Herida Quirúrgica/prevención & control , Infección de la Herida Quirúrgica/etiología , Cicatrización de Heridas , Técnicas de Cierre de Heridas , Europa (Continente) , Canadá , Suturas , Estados Unidos
4.
J Arthroplasty ; 39(4): 878-883, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38244638

RESUMEN

BACKGROUND: The purpose of this modified Delphi study was to obtain consensus on wound closure and dressing management in total knee arthroplasty (TKA). METHODS: The Delphi panel included 20 orthopaedic surgeons from Europe and North America. There were 26 statements identified using a targeted literature review. Consensus was developed for the statements with up to three rounds of anonymous voting per topic. Panelists ranked their agreement with each statement on a five-point Likert scale. An a priori threshold of ≥ 75% was required for consensus. RESULTS: All 26 statements achieved consensus after three rounds of anonymous voting. Wound closure-related interventions that were recommended for use in TKA included: 1) closing in semi-flexion versus extension (superior range of motion); 2) using aspirin for venous thromboembolism prophylaxis over other agents (reduces wound complications); 3) barbed sutures over non-barbed sutures (lower wound complications, better cosmetic appearances, shorter closing times, and overall cost savings); 4) mesh-adhesives over other skin closure methods (lower wound complications, higher patient satisfaction scores, lower rates of readmission); 5) silver-impregnated dressings over standard dressings (lower wound complications, decreased infections, fewer dressing changes); 6) in high-risk patients, negative pressure wound therapy over other dressings (lower wound complications, decreased reoperations, fewer dressing changes); and 7) using triclosan-coated over non-antimicrobial-coated sutures (lower risks of surgical site infection). CONCLUSIONS: Using a modified Delphi approach, the panel achieved consensus on 26 statements pertaining to wound closure and dressing management in TKA. This study forms the basis for identifying critical evidence supported by clinical practice for wound management to help reduce variability, advance standardization, and ultimately improve outcomes during TKA. The results presented here can serve as the foundation for knowledge, education, and improved clinical outcomes for surgeons performing TKAs.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Vendajes , Técnica Delphi , Reoperación , Infección de la Herida Quirúrgica/prevención & control , Infección de la Herida Quirúrgica/etiología , Suturas
5.
J Arthroplasty ; 38(4): 691-699, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36272510

RESUMEN

BACKGROUND: Cementless total knee arthroplasty (TKA) is the subject of renewed interest. Previous concerns about survivorship have been addressed and there is an appeal in terms of biological fixation and surgical efficiency. However, even surgeon advocates have concerns about the risk of marked subsidence when using this technology in older patients at risk for osteoporosis. METHODS: This was a retrospective analysis of 1,000 consecutive fully cementless mobile bearing TKAs performed at a single institution on women over 75 years of age who had postoperative and 1-year x-rays. The primary outcome was the incidence of subsidence. RESULTS: There were three asymptomatic cases with definite subsidence and change in alignment. In a fourth symptomatic case, the femoral component subsided into varus and the tibia into valgus, thus maintaining alignment which facilitated nonoperative treatment in a 92-year-old. Overall, at 1 year, there were two- liner revisions for infection without recurrence. Five patients had further surgery, of which three were washouts and two were for periprosthetic fractures sustained postoperatively within 1 year. Seven patients had further anesthesia, of which five were manipulations and two were nonrecurrent closed reductions for spinouts. CONCLUSION: Cementless TKA did not have a high risk of subsidence in this at-risk population. In the hands of experienced surgeons, these procedures can be used safely irrespective of bone quality.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Estudios Retrospectivos , Prótesis de la Rodilla/efectos adversos , Tibia/cirugía , Radiografía , Reoperación , Resultado del Tratamiento
6.
J Arthroplasty ; 36(10): 3543-3550, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34183212

RESUMEN

BACKGROUND: We aimed to evaluate the outcomes of hybrid fixation technique in condylar revision total knee arthroplasty (rTKA) using cementless metaphyseal tibial sleeves and short-cemented femoral stems with a rotating platform articulation. METHODS: Retrospective consecutive study of all condylar rTKAs with a cemented femoral stem between 2009 and 2016 was conducted. Patients were identified using a local prospective database and linkable data obtained from the National Joint Registry for rTKA. Demographic, clinical, and surgical data were collected from patients' electronic health records. The primary outcome measure was mechanical failure and implant survivorship using a nationally collected data, complications, re-operations, and "any-cause revision" were also recorded. RESULTS: There were 72 consecutive patients (72 knees) with minimum 5-year follow-up: 33 (45.8%) females and 39 (54.2%) males with a median age of 70 years (range 47-88). The indication for revision surgery was aseptic loosening (n = 34, 47.2%), instability (n = 17, 23.6%), infection (n = 14, 19.5%) with 10 patients having 2-stage approach and 4 patients with single-stage approach, stiffness (n = 4, 5.6%), and malalignment (n = 3, 4.1%). At mean follow-up of 6.87 years (median 6.7; range 5-11.8), only 2 patients required revision for infection. Using "any-cause implant revision" as an end point, implant survivorship for this construct was 97.2% at median 6.7 years. To date, none of the femoral stems have been revised for mechanical failure. CONCLUSION: In rTKA with good femoral condylar bone stock, we have shown excellent survivorship with a short-cemented femoral stem, in conjunction with a mobile-bearing and a tibial sleeve. This has the advantage of reducing the length of the revision construct of this complex surgery. LEVEL OF EVIDENCE: Level IV.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Prótesis de la Rodilla/efectos adversos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Supervivencia
7.
J Arthroplasty ; 36(6): 2131-2136, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33610410

RESUMEN

BACKGROUND: The aim of this study is to examine the differences in long-term mortality rates between septic and aseptic revision total knee arthroplasty (rTKA) in a single specialist center over 17-year period. METHODS: Retrospective consecutive study of all patients who underwent rTKA at our tertiary center between 2003 and 2019 was carried out. Revisions were classified as septic or aseptic. We identified patients' age, gender, American Society of Anesthesiologists grade, and body mass index. The primary outcome measure was all-cause mortality at 5 years, 10 years, and over the whole study period of 17 years. Death was identified through both local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival curves were used to estimate time to death. RESULTS: In total, 1298 consecutive knee revisions were performed on 1254 patients (44 bilateral revisions) with 985 aseptic revisions in 945 patients (75.4%) and 313 septic revisions in 309 patients (24.6%). Average age was 70.6 years (range 27-95) with 720 females (57.4%). Septic revisions had higher mortality rates; patients' survivorship for septic vs aseptic revisions was 77.6% vs 89.5% at 5 years, 68.7% vs 80.2% at 10 years, and 66.1% vs 75.0% at 17 years; these differences were all statistically significant (P < .0001). The unadjusted 10-year risk ratio of death after septic revision was 1.59 (95% confidence interval 1.29-1.96) compared to aseptic revisions. CONCLUSION: rTKA performed for infection is associated with significantly higher long-term mortality at all time points compared with aseptic revision surgery. LEVEL OF EVIDENCE: Level IV.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Articulación de la Rodilla/cirugía , Estudios Longitudinales , Persona de Mediana Edad , Falla de Prótesis , Reoperación , Estudios Retrospectivos
8.
J Arthroplasty ; 35(2): 495-499, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31606290

RESUMEN

BACKGROUND: Addressing bone loss and securing implant fixation can be challenging in revision total knee arthroplasty (TKA). We present the results of a large series of revision TKAs using a metaphyseal sleeve. METHODS: We retrospectively analyzed 319 revision TKAs with the use of a metaphyseal sleeve that had been followed up for at least 2 years, using a prospectively collected database. The mean follow-up was 91 months, and 73 patients were followed up for more than 10 years. RESULTS: Implant survivorship was 99.1% at 3 years, 98.7% at 5 years, and 97.8% at 10 years. No metaphyseal sleeve was revised for aseptic loosening. Final radiographic review showed that there were radiolucent lines present in 2.8% of tibial sleeves and 2.7% of femoral sleeves; none of these had progressed and none were revised. About 3.7% of tibial sleeves subsided more than 1 mm compared with the immediate postoperative X-ray but all stabilized and none were revised. CONCLUSION: Use of a metaphyseal sleeve in revision TKA is associated with excellent survivorship and radiographic outcome in the medium to long term.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Articulación de la Rodilla/cirugía , Diseño de Prótesis , Reoperación , Estudios Retrospectivos , Supervivencia , Resultado del Tratamiento
9.
Eur J Orthop Surg Traumatol ; 28(1): 109-115, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28780594

RESUMEN

Two-stage revision surgery for infected total knee replacements remains the gold standard treatment. Articulating spacers are preferred to static spacers for improved functional outcome. Articulating spacers made of cement can be prone to fracture, may not be suitable for full weight bearing, create abrasion debris and necessitate second-stage revision surgery. An alternative is the use of primary knee replacement implants as temporary spacers. With this technique, implants are loosely cemented into place at time of revision, allow the patient reasonable mobility and an ability to fully weight bear and can obviate the need for second-stage surgery. A retrospective review of all patients undergoing revision for infection over two years was conducted. Patients were clinically assigned to single- or two-stage revision. Patients who had a temporary knee replacement, that is, a primary knee replacement used as an articulating spacer, were identified and contacted to complete an Oxford Knee Score. Time to second stage and recurrence was identified from the notes 23 patients received temporary knee replacements. Of these, one patient died, 13 proceeded to a second-stage revision and nine remain in situ. Median time to second-stage revision was 19 weeks [range 11-27]. No patients had re-infection. Median follow-up for ongoing temporary knee replacements was 43 weeks [range 24-90]. Four temporary implants had survived for longer than 1 year. Median Oxford Knee Score was 26 [23-32] and satisfaction score was 8 out of 10 [8-8]. These early results show that knee replacement implants used as spacers provide a good alternative to cement-based articulating spacers with low re-infection rates. Their additional cost when compared with cement spacers is offset by the fact that many patients achieve adequate function and frail patients can avoid a revision procedure. Level of evidence Case series, Level IV.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Prótesis de la Rodilla , Infecciones Relacionadas con Prótesis/cirugía , Reoperación/métodos , Anciano , Anciano de 80 o más Años , Artrodesis , Cementos para Huesos/uso terapéutico , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/fisiopatología , Prótesis de la Rodilla/efectos adversos , Infecciones Relacionadas con Prótesis/etiología , Estudios Retrospectivos
10.
JBJS Case Connect ; 14(2)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38870317

RESUMEN

CASE: A patient underwent revision of a total knee replacement to a cementless rotating-hinge prosthesis. The femoral component became loose, but due to the patient's frailty and cognitive decline, revision was not performed. Subsequently, the yoke failed, dissociating the femoral and tibial components, necessitating a single-stage revision. CONCLUSION: This case underlines the need for robust fixation of components of rotating-hinge knee replacements to avoid mechanical failures. It contributes valuable insights to the limited literature on yoke failure in total knee arthroplasty, emphasizing the importance of implant design, patient selection, and surgical technique to prevent such complications.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Falla de Prótesis , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Reoperación , Anciano , Femenino , Diseño de Prótesis , Masculino
11.
Arthroplasty ; 6(1): 46, 2024 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-39095924

RESUMEN

BACKGROUND: The Attune TKR was introduced in 2011 as a successor to its predicate design The PFC Sigma. However, following reports of early failures, there are ongoing concerns related to increased loosening rates. Given the concerns, this study aimed to compare revision rates of the Attune implant to an established predicate, and other implant designs used in a high-volume arthroplasty center. METHODS: We identified 10,202 patients who underwent primary cemented TKR at our institution with a minimum of 1 year follow-up, involving 2406 Attune TKR (557 S +), 4642 PFC TKR, 3154 other designs. Primary outcomes were revision for all-causes, aseptic loosening of any component, and aseptic tibial loosening. Kaplan-Meier survival and Cox regression models were used to compare groups. Matched cohorts were selected for radiographic analysis. RESULTS: 308 knees were revised. The Attune cohort had the lowest risk of revision, with a rate of 2.98 per 1000 implant-years while the PFC and All Other Implant groups had a rate of 3.15 and 4.4 respectively. Aseptic loosing was the most common cause for revision, with 76% (65/88) involving the tibia. Survival analysis showed no significant differences between the Attune and other cohorts. Radiolucent lines were detected in 7.1% of the Attune S + group, 6.8% of the standard Attune group, and 6.3% of the PFC group, with no significant differences found between them. CONCLUSION: This study represents the largest non-registry review of the Attune TKR in comparison to a predicate and other designs. There was no significant increased revision rate for all-cause revision or aseptic loosening, or peri-implant radiolucencies. It appears that increased loosening may not be as concerning as originally thought. LEVEL OF EVIDENCE: Level III.

12.
J Exp Orthop ; 11(3): e12067, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39011084

RESUMEN

Purpose: Obesity is prevalent, with nearly one-third of the world's population being classified as obese. In patients with high body mass index (BMI)/body mass undergoing total knee arthroplasty (TKA), there is an increase in strain placed on the implant fixation interfaces. As such, component fixation is a potential concern when performing TKA in the obese patient. To address the growing concerns around the longevity of implant fixation, some have advocated cementless over cemented fixation. However, there is no clear consensus on whether a cementless fixation has more favourable outcomes. The aim of this paper was to present a systematic review and meta-analysis of the existing evidence to establish if cementless TKA has a lower rate of aseptic loosening in high BMI patients when compared to cemented TKA procedures. Methods: A systematic review was performed, and the following databases Medical Literature Analysis and Retrieval System Online (1946 to date), PubMed (1966 to date) and Excerpta Medica Database (1974 to date) were searched. All studies comparing cementless to cemented TKA in patients with BMI > 30 were considered. Meta-analysis compared aseptic loosening and all-cause revision between cemented and uncemented implant use in BMI > 30 patients. Results: The search returned 91 articles in total; after duplicates were removed, the yield was 44 studies. Of the remaining studies that were assessed, three studies met the inclusion criteria for meta-analysis. The pooled odds ratio for all-cause revisions was 0.17 (95%, 0.08-0.36) in favour of uncemented implants (p < 0.01). The pooled odds ratio for aseptic loosening was 0.15 (95% confidence interval, 0.02-0.90) in favour of uncemented implants (p = 0.04). Conclusions: Meta-analysis demonstrated a significant decrease in all-cause revisions and revisions for aseptic loosening when using uncemented fixation in high BMI patients when compared to the use of cemented implants. Level of Evidence: The level of evidence is 1 for our systematic review.

13.
Arthroplast Today ; 27: 101397, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38882466

RESUMEN

Background: Stiffness is a common complication following total knee arthroplasty. Manipulation under anesthesia (MUA) is an intervention that can potentially improve range of motion (ROM). Continuous passive motion (CPM) therapy has been utilized to enhance post-MUA ROM, but its effectiveness remains debated. This study assesses whether CPM therapy after MUA results in superior ROM outcomes compared to MUA alone. Methods: A retrospective analysis included patients undergoing MUA for stiff primary total knee arthroplasty between 2017 and 2022. Demographics and ROM data were collected. Patients were in 2 groups: those who received inpatient CPM post-MUA and those who received day-case MUA alone. Complications and further interventions were noted. Results: Of 126 patients, 39 underwent MUA only (day-case group), and 87 received CPM and MUA (inpatient group). Mean preoperative ROM was 69.4° (standard deviation [SD]:18.0°) and 73.9° (SD: 18.1°) for inpatient and day-case groups, respectively. Mean post-MUA ROM improved by 39.4° (SD: 17.7°) and 25.5° (SD: 11.1°) inpatient groups and day-case, respectively. The mean percentage of ROM gained at MUA maintained at final follow-up was 63.7% (40.8%) and 67.0% (47.5%) inpatient and day-case groups, respectively. Conclusions: This study found no advantage in the routine use of CPM post-MUA for stiff total knee replacement patients, suggesting it may not provide sustained ROM improvements compared to MUA alone. Cost-effectiveness and patient selection merit further investigation.

14.
Bone Jt Open ; 4(10): 776-781, 2023 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-37839799

RESUMEN

Aims: The aim of this study was to evaluate medium- to long-term outcomes and complications of the Stanmore Modular Individualised Lower Extremity System (SMILES) rotating hinge implant in revision total knee arthroplasty (rTKA) at a tertiary unit. It is hypothesized that this fully cemented construct leads to satisfactory clinical outcomes. Methods: A retrospective consecutive study of all patients who underwent a rTKA using the fully cemented SMILES rotating hinge prosthesis between 2005 to 2018. Outcome measures included aseptic loosening, reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both prospectively collected local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years. Results: Overall, 69 consecutive patients (69 knees) were included with a median age of 78 years (interquartile range 69 to 84), and there were 46 females (66.7%). Indications were septic revisions in 26 (37.7%), and aseptic aetiology in the remining 43 (62.3%). The mean follow-up was 9.7 years (4 to 18), and the overall complication was rate was 7.24%, all with patellofemoral complications. Failure rate with 'any cause revision' was 5.8%. There was one case of aseptic loosening of the femoral component. At ten years, 17/69 patients (24.63%) had died, and implant survivorship was 92.2%. Conclusion: In our experience, the SMILES rotating hinge prosthesis achieves satisfactory long-term outcomes with ten-year implant survivorship of 92.2% and a patellofemoral complication rate of 7.24%.

15.
Arthroplast Today ; 19: 101086, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36688095

RESUMEN

Background: Ceramic coatings in total knee arthroplasty have been introduced with the aim of reducing wear and consequently improving implant survivorship. We studied both cobalt-chrome-molybdenum (CoCrMo) and ceramic-coated components of the same implant design from a single center to identify if the ceramic coating conferred any benefit. Methods: We identified 1641 Columbus total knee arthroplasties (Aesculap AG, Tüttlingen, Germany) from a prospectively collected arthroplasty database. Of the 1641, 983 were traditional CoCrMo, and 659 had the Columbus AS ceramic coating. Patients were followed up until death or revision of any component of the implant. Results: There was no significant difference in implant survivorship using any component revision as the endpoint between the CoCrMo femur and the ceramic-coated femur at a mean of 9.2 years in follow-up for the CoCrMo group and 5 years for the ceramic-coated group (37 vs 14; P = .76). There was no reduction in the proportion of components revised for aseptic loosening or infection in the ceramic-coated cohort. Conclusions: At midterm follow-up, there was no benefit in terms of implant survivorship in using a ceramic coating.

16.
Bone Joint J ; 105-B(6): 641-648, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-37257848

RESUMEN

Aims: Revision total knee arthroplasty (rTKA) and revision total hip arthroplasty (rTHA) are complex procedures with higher rates of re-revision, complications, and mortality compared to primary TKA and THA. We report the effects of the establishment of a revision arthroplasty network (the East Midlands Specialist Orthopaedic Network; EMSON) on outcomes of rTKA and rTHA. Methods: The revision arthroplasty network was established in January 2015 and covered five hospitals in the Nottinghamshire and Lincolnshire areas of the East Midlands of England. This comprises a collaborative weekly multidisciplinary meeting where upcoming rTKA and rTHA procedures are discussed, and a plan agreed. Using the Hospital Episode Statistics database, revision procedures carried out between April 2011 and March 2018 (allowing two-year follow-up) from the five network hospitals were compared to all other hospitals in England. Age, sex, and mean Hospital Frailty Risk scores were used as covariates. The primary outcome was re-revision surgery within one year of the index revision. Secondary outcomes were re-revision surgery within two years, any complication within one and two years, and median length of hospital stay. Results: A total of 57,621 rTHA and 33,828 rTKA procedures were performed across England, of which 1,485 (2.6%) and 1,028 (3.0%), respectively, were conducted within the network. Re-revision rates within one year for rTHA were 7.3% and 6.0%, and for rTKA were 11.6% and 7.4% pre- and postintervention, respectively, within the network. This compares to a pre-to-post change from 7.4% to 6.8% for rTHA and from 11.7% to 9.7% for rTKA for the rest of England. In comparative interrupted time-series analysis for rTKA there was a significant immediate improvement in one-year re-revision rates for the revision network compared to the rest of England (p = 0.024), but no significant change for rTHA (p = 0.504). For the secondary outcomes studied, there was a significant improvement in trend for one- and two-year complication rates for rTHA for the revision network compared to the rest of England. Conclusion: Re-revision rates for rTKA and complication rates for rTHA improved significantly at one and two years with the introduction of a revision arthroplasty network, when compared to the rest of England. Most of the outcomes studied improved to a greater extent in the network hospitals compared to the rest of England when comparing the pre- and postintervention periods.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Factores de Riesgo , Reoperación , Bases de Datos Factuales , Estudios Retrospectivos
17.
J Long Term Eff Med Implants ; 32(4): 57-61, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36017928

RESUMEN

The use of metaphyseal sleeves in revision total knee arthroplasty has gained popularity with numerous clinical series demonstrating excellent osseointegration and survivorship at medium- to long-term follow up. Once osseointegrated, sleeves provide excellent biological fixation and are difficult to remove. Here, we describe our surgical technique and sequence in removing metaphyseal sleeves in contemporary revision knee systems with case demonstrations.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Artroplastia de Reemplazo de Rodilla/métodos , Humanos , Articulación de la Rodilla/cirugía , Diseño de Prótesis , Reoperación
18.
J Long Term Eff Med Implants ; 33(1): 23-29, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36382701

RESUMEN

Although extensor mechanism failure remains a catastrophic complication of knee arthroplasty, there are a number of contemporary techniques with reasonable outcomes that restore function. Chronic failures require advanced reconstruction techniques. Similar complication rates have been reported for the use of autografts, allografts, or mesh reconstructions. Here, we describe our surgical technique in allograft extensor mechanism reconstruction for chronic failures in salvage revision knee arthroplasty using a complete extensor mechanism allograft with a modified proximal fixation and case demonstrations.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla , Rango del Movimiento Articular , Trasplante Homólogo , Aloinjertos , Reoperación
19.
Bone Jt Open ; 3(3): 205-210, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35274992

RESUMEN

AIMS: The aim of this study was to evaluate medium-term outcomes and complications of the S-ROM NOILES Rotating Hinge Knee System (DePuy, USA) in revision total knee arthroplasty (rTKA) at a tertiary unit. METHODS: A retrospective consecutive study of all patients who underwent a rTKA using this implant from January 2005 to December 2018. Outcome measures included reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years. RESULTS: A total of 89 consecutive patients (89 knees) were included with 47 females (52.8%) and a median age of 74 years (interquartile range 66 to 79). The main indications were aseptic loosening with instability (39.4%; n = 35) and infection (37.1%; n = 33) with the majority of patients managed through two-stage approach. The mean follow-up was 7.4 years (2 to 16). The overall rate of reoperation, for any cause, was 10.1% (n = 9) with a rate of implant revision of 6.7% (n = 6). Only two cases required surgery for patellofemoral complications. Kaplan-Meier implant-survivorship analysis was 93.3% at ten years, using revision for any cause as an endpoint. CONCLUSION: This implant achieved high ten-year survivorship with a low complication rate, particularly patellofemoral complications. These can be avoided by ensuring central patella tracking and appropriate tension of the patellofemoral joint in this posterior hinge design. Cite this article: Bone Jt Open 2022;3(3):205-210.

20.
Bone Joint J ; 104-B(2): 206-211, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35094580

RESUMEN

AIMS: Total hip arthroplasty (THA) is a very successful and cost-effective operation, yet debate continues about the optimum fixation philosophy in different age groups. The concept of the 'cementless paradox' and the UK 'Getting it Right First Time' initiative encourage increased use of cemented fixation due to purported lower revision rates, especially in elderly patients, and decreased cost. METHODS: In a high-volume, tertiary referral centre, we identified 10,112 THAs from a prospectively collected database, including 1,699 cemented THAs, 5,782 hybrid THAs, and 2,631 cementless THAs. The endpoint was revision for any reason. Secondary analysis included examination of implant survivorship in patients aged over 70 years, over 75 years, and over 80 years at primary THA. RESULTS: Cemented fixation had the lowest implant survival in all age groups, with a total ten-year survivorship of 97.0% (95% confidence interval (CI) 95.8 to 97.8) in the cemented group, 97.6% (95% CI 96.9 to 98.1) in the hybrid group, and 97.9% (95% CI 96.9 to 98.6) in the cementless group. This was not statistically significant (p = 0.092). There was no age group where cemented fixation outperformed hybrid or cementless fixation. CONCLUSION: While all fixation techniques performed well at long-term follow-up, cemented fixation was associated with the lowest implant survival in all age groups, including in more elderly patients. We recommend that surgeons should carefully monitor their own outcomes and use fixation techniques that they are familiar with, and deliver the best outcomes in their own hands. Cite this article: Bone Joint J 2022;104-B(2):206-211.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Cementos para Huesos , Prótesis de Cadera , Falla de Prótesis/etiología , Reoperación/estadística & datos numéricos , Factores de Edad , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/instrumentación , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA