Resultados 1 - 11 de 11
Filtrar
1.
Clin Chem ; 67(11): 1545-1553, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34240163

RESUMEN

BACKGROUND: We evaluated the analytical sensitivity and specificity of 4 rapid antigen diagnostic tests (Ag RDTs) for severe acute respiratory syndrome coronavirus 2, using reverse transcription quantitative PCR (RT-qPCR) as the reference method and further characterizing samples using droplet digital quantitative PCR (ddPCR) and a mass spectrometric antigen test. METHODS: Three hundred fifty (150 negative and 200 RT-qPCR positive) residual PBS samples were tested for antigen using the BD Veritor lateral flow (LF), ACON LF, ACON fluorescence immunoassay (FIA), and LumiraDx FIA. ddPCR was performed on RT-qPCR-positive samples to quantitate the viral load in copies/mL applied to each Ag RDT. Mass spectrometric antigen testing was performed on PBS samples to obtain a set of RT-qPCR-positive, antigen-positive samples for further analysis. RESULTS: All Ag RDTs had nearly 100% specificity compared to RT-qPCR. Overall analytical sensitivity varied from 66.5% to 88.3%. All methods detected antigen in samples with viral load >1 500 000 copies/mL RNA, and detected ≥75% of samples with viral load of 500 000 to 1 500 000 copies/mL. The BD Veritor LF detected only 25% of samples with viral load between 50 000 to 500 000 copies/mL, compared to 75% for the ACON LF device and >80% for LumiraDx and ACON FIA. The ACON FIA detected significantly more samples with viral load <50 000 copies/mL compared to the BD Veritor. Among samples with detectable antigen and viral load <50 000 copies/mL, sensitivity of the Ag RDT varied between 13.0% (BD Veritor) and 78.3% (ACON FIA). CONCLUSIONS: Ag RDTs differ significantly in analytical sensitivity, particularly at viral load <500 000 copies/mL.


Asunto(s)
Antígenos Virales/análisis , Prueba de COVID-19/métodos , Pruebas en el Punto de Atención , Humanos , Espectrometría de Masas , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , SARS-CoV-2/inmunología , Sensibilidad y Especificidad , Carga Viral
2.
BMC Genomics ; 17(1): 814, 2016 10 20.
Artículo en Inglés | MEDLINE | ID: mdl-27765019

RESUMEN

BACKGROUND: RNA-seq is a well-established method for studying the transcriptome. Popular methods for library preparation in RNA-seq such as Illumina TruSeq® RNA v2 kit use a poly-A pulldown strategy. Such methods can cause loss of coverage at the 5' end of genes, impacting the ability to detect fusions when used on degraded samples. The goal of this study was to quantify the effects RNA degradation has on fusion detection when using poly-A selected mRNA and to identify the variables involved in this process. RESULTS: Using both artificially and naturally degraded samples, we found that there is a reduced ability to detect fusions as the distance of the breakpoint from the 3' end of the gene increases. The median transcript coverage decreases exponentially as a function of the distance from the 3' end and there is a linear relationship between the coverage decay rate and the RNA integrity number (RIN). Based on these findings we developed plots that show the probability of detecting a gene fusion ("sensitivity") as a function of the distance of the fusion breakpoint from the 3' end. CONCLUSIONS: This study developed a strategy to assess the impact that RNA degradation has on the ability to detect gene fusions by RNA-seq.


Asunto(s)
Estabilidad del ARN , ARN/genética , Recombinación Genética , Línea Celular Tumoral , Puntos de Rotura del Cromosoma , Proteínas de Fusión bcr-abl/genética , Biblioteca de Genes , Humanos , Leucemia Mielógena Crónica BCR-ABL Positiva/genética , ARN/metabolismo , ARN Mensajero/genética , Análisis de Secuencia de ARN
3.
Diagn Microbiol Infect Dis ; 108(2): 116157, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38101236

RESUMEN

During the first year of the COVID-19 pandemic skyrocketing demand for testing in the United States, coupled with supply chain issues, necessitated the use of multiple SARS-CoV-2 molecular testing platforms at many health centers. At our institution these platforms consisted of 8 ordered services for sample triage, using 9 emergency use authorized (EUA) SARS-CoV-2 RNA nucleic acid amplification tests resulting in 10 possible ordered service/EAU combinations. Here we review the results of the first ∼2.9 million samples tested and note the variability in positivity rates. We conclude that differences in reported limit of detection did not translate to differences in positivity rate or show correlation to discordant results observed. This highlights the importance of balancing patient testing capacity needs with the desire to have more sensitive tests.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Estados Unidos/epidemiología , SARS-CoV-2/genética , COVID-19/diagnóstico , Prueba de COVID-19 , Técnicas de Laboratorio Clínico/métodos , ARN Viral/genética , Pandemias , Hospitales , Sensibilidad y Especificidad
4.
J Appl Lab Med ; 9(4): 704-715, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38767175

RESUMEN

BACKGROUND: The COVID-19 pandemic emphasized an urgent need for devices used in the self-collection of biospecimens in an evolving patient care system. The mailing of biospecimen self-collection kits to patients, with samples returned via mail, provides a more convenient testing regimen, but could also impart patient sampling variabilities. User compliance with device directions is central to downstream testing of collected biospecimens and clear instructions are central to this goal. METHODS: Here, we performed an evaluation of 10 oral DNA collection devices involving either swab or saliva self-collection and analyzed ease of use and comfort level with a device, as well as DNA recovery quantity/quality and sample stability. RESULTS: We show that while these DNA quality/quantity metrics are comparable between devices, users prefer direct saliva collection over swab-based devices. CONCLUSIONS: This information is useful in guiding future experiments including their use in human RNA, microbial, or viral sample collection/recovery and their use in clinical testing.


Asunto(s)
COVID-19 , SARS-CoV-2 , Saliva , Manejo de Especímenes , Humanos , Manejo de Especímenes/métodos , Manejo de Especímenes/instrumentación , Saliva/virología , COVID-19/diagnóstico , COVID-19/virología , SARS-CoV-2/aislamiento & purificación , SARS-CoV-2/genética , ADN/análisis , ADN/aislamiento & purificación
5.
Diagn Microbiol Infect Dis ; 105(3): 115880, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36669396

RESUMEN

On February 29th, 2020, the U.S. Food and Drug Administration issued the first Emergency Use Authorization (EUA) for a SARS-CoV-2 assay outside of the U.S. Centers for Disease Control and Prevention. As of May 3rd, 2021, 289 total EUAs have been granted. Like influenza, there is no standard for defining limit of detection (LoD), but rather guidance that analytical sensitivity/LoD be established as the level that gives a 95% detection rate in at least 20 replicates. Here we compare the performance characteristics of SARS-CoV-2 tests receiving EUA by standardizing sensitivity to a common unit of measure and assess the variability in LoD between tests. Additionally, we looked at factors that may impact sensitivities due to lack of standardization of the test development process and compare results for a standardized reference panel for comparative analysis within a subset of EUA tests offered by the U.S. Food and Drug Administration.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Prueba de COVID-19 , Límite de Detección , Técnicas de Laboratorio Clínico/métodos , Sensibilidad y Especificidad
6.
SLAS Technol ; 27(3): 214-218, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35058215

RESUMEN

Capture-based library preparation for next generation sequencing (NGS) offers a balance between sequencing depth and bioinformatics cost of analysis. Liquid handling automation enhances the reliability of the library preparation process by reducing sample-to-sample variation and substantially enhances throughput, particularly when it can be employed in a 'walk-away' fashion with limited hands-on interaction. This requires complex series of mixing and heating steps like those utilized in capture chemistries to happen on the liquid handler. While developing liquid handling automation for Integrated DNA Technologies (IDT) xGen Exome, Illumina TruSight Oncology 500, and Personal Genome Diagnostics (PGDx) elio Plasma Resolve chemistries on the PerkinElmer Sciclone liquid handler, we found that applying the capture temperatures recommended for manual library preparation results in low yield on automation. To restore the final library yield, we reduced bead binding and/or heated wash temperatures of the Peltier heaters on the liquid handlers by about 10°C. Since this applied across three unique capture-based chemistries, we consider this a generalizable principle of automating capture on the Sciclone. We hypothesize that this is driven by the very different thermodynamic environments represented by a sealed plate on a thermal cycler and a plate with a lid on a Peltier heater. This phenomenon should be considered when automating NGS library preparation on PerkinElmer Sciclone instruments.


Asunto(s)
Secuenciación de Nucleótidos de Alto Rendimiento , Automatización , Biblioteca de Genes , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Reproducibilidad de los Resultados , Temperatura
7.
J Clin Virol Plus ; 1(3): 100030, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35262016

RESUMEN

Serologic testing for SARS-CoV-2 can be used for evaluation of past infection in individual patients and for community seroprevalence studies. We evaluated the analytical and clinical performance of the Genalyte Maverick SARS-CoV-2 Multi-Antigen Serology Panel compared to the Roche Elecsys Anti-SARS-CoV-2 nucleocapsid (NC) qualitative immunoassay, using well characterized clinical serum samples. A total of 143 pre-pandemic sera and 48 sera collected from patients with a negative molecular SARS-CoV-2 result were used for specificity studies. For sensitivity analyses, 179 sera were used, obtained 3-7 days, 8-14 days, or ≥ 15 days after symptom onset from patients with confirmed SARS-CoV-2 infection. Specificity was determined to be 95.3% (182/191) for the Genalyte Maverick. Overall sensitivity of the Genalyte Maverick was similar to that observed for the Roche Elecsys NC test, 79.3% (142/179) vs. 76.5% (137/179), respectively. Genalyte Maverick trended, without statistical significance, towards higher sensitivity as compared to the Roche Elecsys NC test in the 3-7 days (11/25 vs. 9/25, respectively) and 8-14 days (21/28 vs. 19/28, respectively) post-symptom onset sample sets, but was identical in the ≥ 15 days post-symptom onset group (106/116 vs. 106/116, respectively). Therefore, the Genalyte Maverick serologic test had similar overall sensitivity to the Roche Elecsys NC assay, but may have slightly improved sensitivity for early seroconversion. The lower Genalyte Maverick specificity as compared to the Roche Elecsys NC assay as reported by other studies (>99%), may necessitate confirmatory testing of positive Genalyte Maverick results if implemented for clinical use.

8.
J Mol Diagn ; 23(12): 1732-1740, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34839893

RESUMEN

Complex insertion-deletion (indel) events in the globin genes manifest in widely variable clinical phenotypes. Many are incompletely characterized because of a historic lack of efficient methods. A more complete assessment enables improved prediction of clinical impact, which guides emerging therapeutic choices. Current methods have limited capacity for breakpoint assignment and accurate assessment of mutation extent, especially in cases containing duplications or multiple deletions and insertions. Technology, such as long-read sequencing, holds promise for significant impact in the characterization of indel events because of read lengths that span large regions, resulting in improved resolution. Four known complex ß-globin gene cluster indel types were assessed using single-molecule, real-time sequencing technology and showed high correlation with previous reports, including the Caribbean locus control deletion (g.5,305,478_5,310,336del), a large ß-gene duplication containing the Hb S mutation (g.4,640,335_5,290,171dup with g.5,248,232T>A, c.20A>T; variant allele fraction, 64%), and two nested variants (double deletions with intervening inversion): the Indian Gγ(Aγδß)0-thalassemia (g.5,246,804-5,254,275del, g.5,254,276_5,269,600inv, and g.5,269,601_5,270,442del) and the Turkish/Macedonian (δß)0 thalassemia (g.5,235,064_5,236,652del, g.5,236,653_5,244,280inv, and g.5,244,281_5,255,766del). Our data confirm long-read sequencing as an efficient and accurate method to identify these clinically significant complex events. Limitations include high-complexity sample preparation requirements, which hinder routine use in clinical laboratories. Continued improvements in sample and data workflow processes are needed to accommodate volumes in a tertiary clinical laboratory.


Asunto(s)
Análisis de Secuencia de ADN/métodos , Talasemia/genética , Globinas beta/genética , Anemia de Células Falciformes/genética , Femenino , Duplicación de Gen , Heterocigoto , Humanos , India , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Familia de Multigenes , Globinas beta/análisis
9.
J Mol Diagn ; 23(5): 555-564, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33549857

RESUMEN

Tumor mutation burden (TMB) is an emerging biomarker of immunotherapy response. RNA sequencing in FFPE tissue samples was used for determining TMB in microsatellite-stable (MSS) and microsatellite instability-high (MSI-H) tumors in patients with colorectal or endometrial cancer. Tissue from tumors and paired normal tissue from 46 MSI-H and 12 MSS cases were included. Of the MSI-H tumors, 29 had defective DNA mismatch-repair mutations, and 17 had MLH1 promoter hypermethylation. TMB was measured using the expressed somatic nucleotide variants (eTMB). A method of accurate measurement of eTMB was developed that removes FFPE-derived artifacts by leveraging mutation signatures. There was a significant difference in the median eTMB values observed between MSI-H and MSS cases: 27.3 versus 6.7 mutations/megabase (mut/Mb) (P = 3.5 × 10-9). Among tumors with defective DNA-mismatch repair, those with mismatch-repair mutations had a significantly higher median eTMB than those with hypermethylation: 28.1 versus 17.5 mut/Mb (P = 0.037). Multivariate analysis showed that MSI status, tumor type (endometrial or colorectal), and age were significantly associated with eTMB. Additionally, using whole-exome sequencing in a subset of these patients, it was determined that DNA TMB correlated well with eTMB (Spearman correlation coefficient, 0.83). These results demonstrate that RNA sequencing can be used for measuring eTMB in FFPE tumor specimens.


Asunto(s)
Biomarcadores de Tumor/genética , Neoplasias Colorrectales/patología , Reparación de la Incompatibilidad de ADN/genética , Neoplasias Endometriales/patología , Mutación , RNA-Seq/métodos , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias Colorrectales/genética , Neoplasias Endometriales/genética , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos
10.
J Mol Diagn ; 18(3): 438-445, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-26947514

RESUMEN

Significant barriers, such as lack of professional guidelines, specialized training for interpretation of pharmacogenomics (PGx) data, and insufficient evidence to support clinical utility, prevent preemptive PGx testing from being widely clinically implemented. The current study, as a pilot project for the Right Drug, Right Dose, Right Time-Using Genomic Data to Individualize Treatment Protocol, was designed to evaluate the impact of preemptive PGx and to optimize the workflow in the clinic setting. We used an 84-gene next-generation sequencing panel that included SLCO1B1, CYP2C19, CYP2C9, and VKORC1 together with a custom-designed CYP2D6 testing cascade to genotype the 1013 subjects in laboratories approved by the Clinical Laboratory Improvement Act. Actionable PGx variants were placed in patient's electronic medical records where integrated clinical decision support rules alert providers when a relevant medication is ordered. The fraction of this cohort carrying actionable PGx variant(s) in individual genes ranged from 30% (SLCO1B1) to 79% (CYP2D6). When considering all five genes together, 99% of the subjects carried an actionable PGx variant(s) in at least one gene. Our study provides evidence in favor of preemptive PGx testing by identifying the risk of a variant being present in the population we studied.


Asunto(s)
Citocromo P-450 CYP2D6/genética , Genotipo , Secuenciación de Nucleótidos de Alto Rendimiento , Farmacogenética/métodos , Medicina de Precisión/métodos , Alelos , Citocromo P-450 CYP2C19/genética , Citocromo P-450 CYP2C19/metabolismo , Citocromo P-450 CYP2D6/metabolismo , Activación Enzimática , Duplicación de Gen , Humanos , Fenotipo
11.
Mayo Clin Proc ; 89(1): 25-33, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24388019

RESUMEN

OBJECTIVE: To report the design and implementation of the Right Drug, Right Dose, Right Time-Using Genomic Data to Individualize Treatment protocol that was developed to test the concept that prescribers can deliver genome-guided therapy at the point of care by using preemptive pharmacogenomics (PGx) data and clinical decision support (CDS) integrated into the electronic medical record (EMR). PATIENTS AND METHODS: We used a multivariate prediction model to identify patients with a high risk of initiating statin therapy within 3 years. The model was used to target a study cohort most likely to benefit from preemptive PGx testing among the Mayo Clinic Biobank participants, with a recruitment goal of 1000 patients. We used a Cox proportional hazards model with variables selected through the Lasso shrinkage method. An operational CDS model was adapted to implement PGx rules within the EMR. RESULTS: The prediction model included age, sex, race, and 6 chronic diseases categorized by the Clinical Classifications Software for International Classification of Diseases, Ninth Revision codes (dyslipidemia, diabetes, peripheral atherosclerosis, disease of the blood-forming organs, coronary atherosclerosis and other heart diseases, and hypertension). Of the 2000 Biobank participants invited, 1013 (51%) provided blood samples, 256 (13%) declined participation, 555 (28%) did not respond, and 176 (9%) consented but did not provide a blood sample within the recruitment window (October 4, 2012, through March 20, 2013). Preemptive PGx testing included CYP2D6 genotyping and targeted sequencing of 84 PGx genes. Synchronous real-time CDS was integrated into the EMR and flagged potential patient-specific drug-gene interactions and provided therapeutic guidance. CONCLUSION: This translational project provides an opportunity to begin to evaluate the impact of preemptive sequencing and EMR-driven genome-guided therapy. These interventions will improve understanding and implementation of genomic data in clinical practice.


Asunto(s)
Pruebas Genéticas/normas , Farmacogenética/métodos , Guías de Práctica Clínica como Asunto , Medicina de Precisión/métodos , Aterosclerosis/tratamiento farmacológico , Estudios de Cohortes , Toma de Decisiones , Diabetes Mellitus/tratamiento farmacológico , Dislipidemias/tratamiento farmacológico , Registros Electrónicos de Salud , Femenino , Técnicas de Genotipaje , Hematopoyesis/efectos de los fármacos , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Hipertensión/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Farmacogenética/normas , Proyectos Piloto , Medicina de Precisión/normas , Valor Predictivo de las Pruebas , Estados Unidos