Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Am J Perinatol ; 38(9): 869-879, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33368094

RESUMEN

OBJECTIVE: We compare maternal morbidity and clinical care metrics before and after the electronic implementation of a maternal early warning trigger (MEWT) tool. STUDY DESIGN: This is a study of maternal morbidity and clinical care within three linked hospitals comparing 1 year before and after electronic MEWT implementation. We compare severe maternal morbidity overall as well as within the subcategories of hemorrhage, hypertension, cardiopulmonary, and sepsis in addition to relevant process metrics in each category. We describe the MEWT trigger rate in addition to MEWT sensitivity and specificity for morbidity overall and by morbidity type. RESULTS: The morbidity rate ratio increased from 1.6 per 100 deliveries in the pre-MEWT period to 2.06 per 100 deliveries in the post-MEWT period (incidence rate ratio = 1.28, p = 0.018); however, in cases of septic morbidity, time to appropriate antibiotics decreased (pre-MEWT: 1.87 hours [1.11-2.63] vs. post-MEWT: 0.75 hours [0.31-1.19], p = 0.036) and in cases of hypertensive morbidity, the proportion of cases treated with appropriate antihypertensive medication within 60 minutes improved (pre-MEWT: 62% vs. post-MEWT: 83%, p = 0.040). The MEWT trigger rate was 2.3%, ranging from 0.8% in the less acute centers to 2.9% in our tertiary center. The MEWT sensitivity for morbidity overall was 50%; detection of hemorrhage morbidity was lowest (30%); however, it ranged between 69% for septic morbidity, 74% for cardiopulmonary morbidity, and 82% for cases of hypertensive morbidity. CONCLUSION: Overall, maternal morbidity did not decrease after implementation of the MEWT system; however, important clinical metrics such as time to antibiotics and antihypertensive care improved. We suspect increased morbidity was related to annual variation and unexpected lower morbidity in the pre-MEWT comparison year. Because MEWT sensitivity for hemorrhage was low, and because hemorrhage dominates administrative metrics of morbidity, process metrics around sepsis, hypertension, and cardiopulmonary morbidity are important to track as markers of MEWT efficacy. KEY POINTS: · MEWT was not associated with a decrease in maternal morbidity.. · MEWT was associated with improvements in some clinical care metrics.. · MEWT is more sensitive in detecting septic, hypertensive, and cardiopulmonary morbidities than hemorrhage morbidity..


Asunto(s)
Diagnóstico Precoz , Sistemas de Registros Médicos Computarizados , Complicaciones del Embarazo/diagnóstico , California/epidemiología , Vías Clínicas , Femenino , Hemorragia/diagnóstico , Humanos , Hipertensión Inducida en el Embarazo/diagnóstico , Mortalidad Materna/tendencias , Morbilidad , Embarazo , Complicaciones del Embarazo/epidemiología , Complicaciones del Embarazo/prevención & control , Curva ROC , Tiempo de Tratamiento
2.
Am J Perinatol ; 36(11): 1106-1114, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-30856674

RESUMEN

OBJECTIVE: We compare validation characteristics of four early warning systems for maternal morbidity. STUDY DESIGN: We used a retrospective cohort of severe maternal morbidity cases between January 2016 and December 2016 compared with a cohort of controls. We determined if the modified early obstetric warning score (MEOWS), maternal early recognition criteria (MERC), modified early warning system (MEWS), or maternal early warning trigger (MEWT) would have alerted. We developed criteria to determine which of these alerts was considered clinically "relevant." RESULTS: We reviewed 79 morbidity cases and 123 controls. MEOWS and MERC were more sensitive than MEWS or MEWT (67.1 and 67.1% vs. 19% and 40.5%, p < 0.001); however, MEWT and MEWS were more specific (88.6% MEWT and 93.5% MEWS vs. 51.2% MEOWS and 60.2% MERC, p < 0.001). In the control population, 70% of MEWT alerts still appeared "relevant" to the clinical scenario in contrast to the MEOWS (32%) or MERC systems (31%). CONCLUSION: There are limited comparative data regarding how early warning systems perform in an American population for maternal morbidity. None of the systems performs with high sensitivity and specificity. High-volume, high-acuity units may decide that the lower sensitivity of the MEWT is relatively acceptable when considering the high false trigger rate of the other more sensitive systems. In addition, triggers in the MEWT system were more likely to be clinically relevant even in cases that did not have severe morbidity.


Asunto(s)
Complicaciones del Trabajo de Parto/diagnóstico , Complicaciones del Embarazo/diagnóstico , Adulto , Biomarcadores , Estudios de Casos y Controles , Femenino , Humanos , Clasificación Internacional de Enfermedades , Embarazo , Estudios Retrospectivos , Sensibilidad y Especificidad , Estados Unidos
3.
AJP Rep ; 13(4): e78-e81, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38033600

RESUMEN

Coronavirus disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2, has led to a global health crisis. The virus can cause varying severity of liver injury, but the mechanism has not yet been elucidated, especially in pregnancy. We present a morbidly obese 30-year-old woman with COVID-19 at 28 weeks' gestation complicated by significant transaminitis with peak liver enzymes levels of 501/1,313 (aspartate aminotransferase/alanine aminotransferase). Liver biopsy showed reactive changes consistent with medication effect and mild steatosis. Significant transaminitis has been found in both pregnant and nonpregnant patients with COVID-19. Our case demonstrates the multifactorial nature of liver injury in COVID-19 patients including mild underlying liver steatosis combined with possible viral potentiation of medication effect.

4.
BMJ Case Rep ; 13(8)2020 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-32843448

RESUMEN

A 19-year-old G1 at 37 weeks presented with acute non-ruptured appendicitis. Her advanced gestational age and surgical anatomy presented a complex surgical scenario. She was treated with intravenous antibiotics and induction of labour, which resulted in resolution of the appendicitis and an uncomplicated vaginal delivery at early term. This case is an example that appendicitis occurring in early-term pregnancy can be successfully managed with intravenous antibiotics, but this is a complex clinical scenario with a limited evidence base to make management decisions. Future studies of medical management of appendicitis in pregnancy, specifically in later gestation, are needed to provide additional information to guide clinicians.


Asunto(s)
Apendicitis/terapia , Complicaciones del Embarazo/terapia , Femenino , Humanos , Embarazo , Tercer Trimestre del Embarazo , Adulto Joven
5.
AJP Rep ; 10(4): e362-e368, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33214931

RESUMEN

Objective American College of Obstetricians and Gynecologists (ACOG) recently published the California (CA) cardiovascular disease (CVD) screening algorithm for pregnant and postpartum women. We aim to prospectively determine screen-positive and true-positive rates of CVD among women across two populations. Study Design This is a prospective cohort study of obstetrical patients from April 2018 to July 2019 at academic medical centers in CA and New York (NY). We attempted to screen all patients at least once during their pregnancy care (prenatal or postpartum). Women who screened positive ("Red Flags," >3-4 moderate risk factors, abnormal physical examination, and persistent symptoms) underwent further testing. The primary outcome was the screen-positive rate. Secondary outcomes included the true-positive rate and the strength of each moderate factor in predicting a positive CVD screen. Results We screened 846 women. The overall screen-positive rate was 8% (5% in CA vs. 19% in NY). The sites differed in ethnicity, that is, African American women (2.7% in CA vs. 35% in NY, p < 0.01) and substance use (2.7 vs. 5.6%, p < 0.04). The true-positive rate was 1.5% at both sites. The percentage of screen-positive patients who did not complete follow-up studies was higher in NY (70%) than in CA (27%). CVD was confirmed in 30% with positive screens with complete follow-up. Combinations of moderate factors were the main driver of screen-positive rates in both populations. Conclusion This is the first data describing the performance of the CVD screening algorithm in a general obstetric population. Factors, such as proportion of African American women affect the likelihood of a positive screen. The screening algorithm highlights patients at higher lifetime risk of CVD and may identify a group that could be targeted for more direct care transitions postpartum. Data may be used to design a larger validation study.

6.
J Am Heart Assoc ; 8(19): e013092, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31564189

RESUMEN

Background Identifying pregnancy-associated risk factors before the development of major cardiovascular disease events could provide opportunities for prevention. The objective of this study was to determine the association between outcomes in first pregnancies and subsequent cardiovascular health. Methods and Results The Nulliparous Pregnancy Outcomes Study Monitoring Mothers-to-be Heart Health Study is a prospective observational cohort that followed 4484 women 2 to 7 years (mean 3.2 years) after their first pregnancy. Adverse pregnancy outcomes (defined as hypertensive disorders of pregnancy, small-for-gestational-age birth, preterm birth, and stillbirth) were identified prospectively in 1017 of the women (22.7%) during this pregnancy. The primary outcome was incident hypertension (HTN). Women without adverse pregnancy outcomes served as controls. Risk ratios (RR) and 95% CIs were adjusted for age, smoking, body mass index, insurance type, and race/ethnicity at enrollment during pregnancy. The overall incidence of HTN was 5.4% (95% CI 4.7% to 6.1%). Women with adverse pregnancy outcomes had higher adjusted risk of HTN at follow-up compared with controls (RR 2.4, 95% CI 1.8-3.1). The association held for individual adverse pregnancy outcomes: any hypertensive disorders of pregnancy (RR 2.7, 95% CI 2.0-3.6), preeclampsia (RR 2.8, 95% CI 2.0-4.0), and preterm birth (RR 2.7, 95% CI 1.9-3.8). Women who had an indicated preterm birth and hypertensive disorders of pregnancy had the highest risk of HTN (RR 4.3, 95% CI 2.7-6.7). Conclusions Several pregnancy complications in the first pregnancy are associated with development of HTN 2 to 7 years later. Preventive care for women should include a detailed pregnancy history to aid in counseling about HTN risk. Clinical Trial Registration URL: http://www.clinicaltrials.gov Unique identifier: NCT02231398.


Asunto(s)
Presión Sanguínea , Hipertensión/epidemiología , Complicaciones del Embarazo/epidemiología , Adulto , Peso al Nacer , Femenino , Edad Gestacional , Humanos , Hipertensión/diagnóstico , Hipertensión/fisiopatología , Incidencia , Recién Nacido , Recien Nacido Prematuro , Recién Nacido Pequeño para la Edad Gestacional , Embarazo , Complicaciones del Embarazo/diagnóstico , Resultado del Embarazo , Pronóstico , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Estados Unidos/epidemiología , Adulto Joven
7.
AJP Rep ; 8(2): e57-e63, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29651358

RESUMEN

Objective We study whether using an intra-aortic balloon (IAB) during cesarean hysterectomy decreases delivery morbidity in patients with suspected morbidly adherent placentation. Study Design This is a retrospective cohort study of deliveries complicated by suspected abnormal placentation between 2009 and 2016 comparing maternal and neonatal outcomes with an IAB placed prior to cesarean hysterectomy versus no IAB. The primary outcome included quantified blood loss (QBL). Results Thirty-five cases were reviewed, 16 with IAB and 19 without IAB. No difference was seen in median QBL between the two groups (1,351 vs. 1,397 mL; p = 0.90). There were no significant differences in overall surgical complications (19% IAB, 21% no IAB; p = 0.86), bladder complications (12 vs. 21%; p = 0.66), intensive care unit admissions (12 vs. 26%; p = 0.41), surgical duration (2.9 vs. 2.8 hour; p = 0.83), or blood transfusions (median 2 vs. 2; p = 0.27) between the two groups. There was one groin hematoma at the balloon site that was managed conservatively. There were no complications involving thrombosis or limb ischemia in the IAB group. Conclusion While we did not detect statistically significant differences, larger studies may be warranted given the potential for extreme morbidity in these cases. This study highlights the potential use of an IAB in the management of these cases.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA