Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Alzheimers Dement ; 20(9): 5833-5848, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39041435

RESUMEN

INTRODUCTION: Tau-positron emission tomography (PET) outcome data of patients with Alzheimer's disease (AD) cannot currently be meaningfully compared or combined when different tracers are used due to differences in tracer properties, instrumentation, and methods of analysis. METHODS: Using head-to-head data from five cohorts with tau PET radiotracers designed to target tau deposition in AD, we tested a joint propagation model (JPM) to harmonize quantification (units termed "CenTauR" [CTR]). JPM is a statistical model that simultaneously models the relationships between head-to-head and anchor point data. JPM was compared to a linear regression approach analogous to the one used in the amyloid PET Centiloid scale. RESULTS: A strong linear relationship was observed between CTR values across brain regions. Using the JPM approach, CTR estimates were similar to, but more accurate than, those derived using the linear regression approach. DISCUSSION: Preliminary findings using the JPM support the development and adoption of a universal scale for tau-PET quantification. HIGHLIGHTS: Tested a novel joint propagation model (JPM) to harmonize quantification of tau PET. Units of common scale are termed "CenTauRs". Tested a Centiloid-like linear regression approach. Using five cohorts with head-to-head tau PET, JPM outperformed linearregressionbased approach. Strong linear relationship was observed between CenTauRs values across brain regions.


Asunto(s)
Enfermedad de Alzheimer , Encéfalo , Tomografía de Emisión de Positrones , Proteínas tau , Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/metabolismo , Humanos , Tomografía de Emisión de Positrones/métodos , Proteínas tau/metabolismo , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Masculino , Femenino , Anciano , Estudios de Cohortes , Radiofármacos , Modelos Estadísticos
2.
Eur J Nucl Med Mol Imaging ; 50(2): 287-301, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36271158

RESUMEN

BACKGROUND: ZED8 is a novel monovalent antibody labeled with zirconium-89 for the molecular imaging of CD8. This work describes nonclinical studies performed in part to provide rationale for and to inform expectations in the early clinical development of ZED8, such as in the studies outlined in clinical trial registry NCT04029181 [1]. METHODS: Surface plasmon resonance, X-ray crystallography, and flow cytometry were used to characterize the ZED8-CD8 binding interaction, its specificity, and its impact on T cell function. Immuno-PET with ZED8 was assessed in huCD8+ tumor-bearing mice and in non-human primates. Plasma antibody levels were measured by ELISA to determine pharmacokinetic parameters, and OLINDA 1.0 was used to estimate radiation dosimetry from image-derived biodistribution data. RESULTS: ZED8 selectively binds to human CD8α at a binding site approximately 9 Å from that of MHCI making mutual interference unlikely. The equilibrium dissociation constant (KD) is 5 nM. ZED8 binds to cynomolgus CD8 with reduced affinity (66 nM) but it has no measurable affinity for rat or mouse CD8. In a series of lymphoma xenografts, ZED8 imaging was able to identify different CD8 levels concordant with flow cytometry. In cynomolgus monkeys with tool compound 89Zr-aCD8v17, lymph nodes were conspicuous by imaging 24 h post-injection, and the pharmacokinetics suggested a flat-fixed first-in-human dose of 4 mg per subject. The whole-body effective dose for an adult human was estimated to be 0.48 mSv/MBq, comparable to existing 89Zr immuno-PET reagents. CONCLUSION: 89Zr immuno-PET with ZED8 appears to be a promising biomarker of tissue CD8 levels suitable for clinical evaluation in cancer patients eligible for immunotherapy.


Asunto(s)
Neoplasias , Tomografía de Emisión de Positrones , Adulto , Humanos , Ratones , Ratas , Animales , Tomografía de Emisión de Positrones/métodos , Indicadores y Reactivos/uso terapéutico , Distribución Tisular , Neoplasias/terapia , Neoplasias/tratamiento farmacológico , Inmunoterapia/métodos , Circonio/química , Linfocitos T CD8-positivos/metabolismo , Línea Celular Tumoral
4.
Alzheimers Dement (Amst) ; 15(3): e12454, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37424964

RESUMEN

INTRODUCTION: Recently, an increasing number of tau tracers have become available. There is a need to standardize quantitative tau measures across tracers, supporting a universal scale. We developed several cortical tau masks and applied them to generate a tau imaging universal scale. METHOD: One thousand forty-five participants underwent tau scans with either 18F-flortaucipir, 18F-MK6240, 18F-PI2620, 18F-PM-PBB3, 18F-GTP1, or 18F-RO948. The universal mask was generated from cognitively unimpaired amyloid beta (Aß)- subjects and Alzheimer's disease (AD) patients with Aß+. Four additional regional cortical masks were defined within the constraints of the universal mask. A universal scale, the CenTauRz, was constructed. RESULTS: None of the regions known to display off-target signal were included in the masks. The CenTauRz allows robust discrimination between low and high levels of tau deposits. DISCUSSION: We constructed several tau-specific cortical masks for the AD continuum and a universal standard scale designed to capture the location and degree of abnormality that can be applied across tracers and across centers. The masks are freely available at https://www.gaain.org/centaur-project.

5.
J Nucl Med Technol ; 48(1): 54-57, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31604892

RESUMEN

Our objective was to harmonize multicenter 89Zr PET imaging for oncology trials and to evaluate lesion detection. Methods: Seven PET scanners were evaluated using a custom chest oncology phantom with 9 spheric lesions 7-20 mm in diameter. A 4:1 signal-to-background ratio simulated a patient dose of 92.5 MBq. Various image reconstructions were evaluated. Images were assessed for lesion detection, and recovery coefficients and background signal variance were measured. Results: Two scanners failed to provide acceptable images and data. Optimal reconstruction algorithms enabling adequate lesion detection and reliable quantification across the other 5 scanners were determined without compromising the data quality. On average, 95% of the 10-mm lesions were detected, and the 7-mm lesion was visualized by only 1 scanner. Background variance was 8.6%-16%. Conclusion: We established multicenter harmonization procedures for 89Zr PET imaging in oncology, optimizing small-lesion (≥10 mm) detectability and accurate quantification.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Pulmón/diagnóstico por imagen , Estudios Multicéntricos como Asunto , Tomografía de Emisión de Positrones/métodos , Radiofármacos , Circonio , Humanos , Fantasmas de Imagen , Radioisótopos
6.
Nat Med ; 24(12): 1852-1858, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30478423

RESUMEN

Programmed cell death protein-1/ligand-1 (PD-1/PD-L1) blockade is effective in a subset of patients with several tumor types, but predicting patient benefit using approved diagnostics is inexact, as some patients with PD-L1-negative tumors also show clinical benefit1,2. Moreover, all biopsy-based tests are subject to the errors and limitations of invasive tissue collection3-11. Preclinical studies of positron-emission tomography (PET) imaging with antibodies to PD-L1 suggested that this imaging method might be an approach to selecting patients12,13. Such a technique, however, requires substantial clinical development and validation. Here we present the initial results from a first-in-human study to assess the feasibility of imaging with zirconium-89-labeled atezolizumab (anti-PD-L1), including biodistribution, and secondly test its potential to predict response to PD-L1 blockade (ClinicalTrials.gov identifiers NCT02453984 and NCT02478099). We imaged 22 patients across three tumor types before the start of atezolizumab therapy. The PET signal, a function of tracer exposure and target expression, was high in lymphoid tissues and at sites of inflammation. In tumors, uptake was generally high but heterogeneous, varying within and among lesions, patients, and tumor types. Intriguingly, clinical responses in our patients were better correlated with pretreatment PET signal than with immunohistochemistry- or RNA-sequencing-based predictive biomarkers, encouraging further development of molecular PET imaging for assessment of PD-L1 status and clinical response prediction.


Asunto(s)
Anticuerpos Monoclonales/administración & dosificación , Antígeno B7-H1/administración & dosificación , Tomografía de Emisión de Positrones , Radioisótopos/administración & dosificación , Circonio/administración & dosificación , Adulto , Anciano , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales Humanizados , Antígeno B7-H1/química , Biopsia , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/patología , Línea Celular Tumoral , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Radioisótopos/química , Radiofármacos/administración & dosificación , Radiofármacos/química , Distribución Tisular/efectos de los fármacos , Neoplasias de la Mama Triple Negativas/diagnóstico por imagen , Neoplasias de la Mama Triple Negativas/patología , Neoplasias de la Vejiga Urinaria/diagnóstico por imagen , Neoplasias de la Vejiga Urinaria/patología , Circonio/química
7.
Clin Cancer Res ; 21(11): 2462-70, 2015 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-26034219

RESUMEN

PURPOSE: The novel dual-action humanized IgG1 antibody MEHD7945A targeting HER3 and EGFR inhibits ligand-dependent HER dimer signaling. This phase I study evaluated the safety, pharmacokinetics, pharmacodynamics, and antitumor activity of MEHD7945A. EXPERIMENTAL DESIGN: Patients with locally advanced or metastatic epithelial tumors received escalating doses of MEHD7945A (1-30 mg/kg) every 2 weeks (q2w) until disease progression or intolerable toxicity. An expansion cohort was enrolled at the recommended phase II dose (14 mg/kg, q2w). Plasma samples, tumor biopsies, FDG-PET were obtained for assessment of pharmacokinetics, and pharmacodynamic modulation downstream of EGFR and HER3. RESULTS: No dose-limiting toxicities or MEHD7945A-related grade ≥ 4 adverse events (AE) were reported in dose-escalation (n = 30) or expansion (n = 36) cohorts. Related grade 3 AEs were limited to diarrhea and nausea in the same patient (30 mg/kg). Related AEs in ≥20% of patients ≤24 hours after the first infusion included grade 1/2 headache, fever, and chills, which were managed with premedication and/or symptomatic treatment. Pharmacodynamic data indicated target inhibition in 25% of evaluable patients. Best response by RECIST included 2 confirmed partial responses in squamous cell carcinomas of head and neck (SCCHN) patients with high tumor tissue levels of the HER3 ligand heregulin; 14 patients had stable disease ≥8 weeks, including SCCHN (n = 3), colorectal cancer (n = 6), and non-small cell lung cancer (n = 3). CONCLUSIONS: MEHD7945A was well-tolerated as single agent with evidence of tumor pharmacodynamic modulation and antitumor activity in SCCHN. Phase II studies were initiated with flat (nonweight-based) dosing at 1,100 mg q2w in SCCHN and colorectal cancer.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Carcinoma de Células Escamosas/tratamiento farmacológico , Receptores ErbB/inmunología , Neoplasias de Cabeza y Cuello/tratamiento farmacológico , Inmunoglobulina G/administración & dosificación , Receptor ErbB-3/inmunología , Adulto , Anciano , Anticuerpos Monoclonales/administración & dosificación , Anticuerpos Monoclonales Humanizados/administración & dosificación , Anticuerpos Monoclonales Humanizados/efectos adversos , Anticuerpos Monoclonales Humanizados/farmacocinética , Protocolos de Quimioterapia Combinada Antineoplásica , Carcinoma de Pulmón de Células no Pequeñas/inmunología , Carcinoma de Pulmón de Células no Pequeñas/patología , Carcinoma de Células Escamosas/inmunología , Carcinoma de Células Escamosas/patología , Cetuximab/administración & dosificación , Relación Dosis-Respuesta a Droga , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/clasificación , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/patología , Receptores ErbB/antagonistas & inhibidores , Clorhidrato de Erlotinib/administración & dosificación , Femenino , Neoplasias de Cabeza y Cuello/inmunología , Neoplasias de Cabeza y Cuello/patología , Humanos , Inmunoglobulina G/efectos adversos , Inmunoglobulina G/inmunología , Masculino , Persona de Mediana Edad , Panitumumab , Receptor ErbB-3/antagonistas & inhibidores , Carcinoma de Células Escamosas de Cabeza y Cuello
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA