Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 97(6): 1230-1234, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33175452

RESUMEN

OBJECTIVES: The aim of this study is to describe the initial experience with versacross transseptal (TS) system for transseptal puncture for the transcatheter mitral valve repair using the MitraClip device. BACKGROUND: Transeptal puncture is a key step in transcatheter mitral valve repair (MVR) and the use of the VersaCross system comprised of a sheath, a dilator and a radiofrequency wire has not been previously described. METHODS: Prospective single center study of consecutive patients undergoing transcatheter mitral valve repair with the MitraClip device were included. Targeted TS puncture was performed under transesophageal echocardiographic (TEE) guidance. Baseline demographics, procedural characteristics, and major adverse procedural events were collected. RESULTS: Twenty-five consecutive patients underwent transseptal puncture using the VersaCross TS system. Transseptal puncture was successful in 100% of patients. The mean time for TS puncture was 3 3 ± 1.6 min with no major adverse procedural events. The mean time from insertion of the VersaCross system to insertion of the MitraClip guide catheter was 3.8 ± 3.0 minutes. CONCLUSION: The VersaCross TS system was successful in all patients for MitraClip procedure with no adverse procedural events and may be associated with increased procedural efficiency.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco/efectos adversos , Ecocardiografía Transesofágica , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Prospectivos , Resultado del Tratamiento
2.
J Card Surg ; 35(7): 1649-1652, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32369863

RESUMEN

Valve-in-valve transcatheter aortic valve implantation is currently used for failed bioprosthesis. The use of a transcatheter prosthesis in a regurgitant noncalcified root implanted Medtronic Freestyle prosthesis is particularly challenging. We present a successful transaxillary valve-in-valve implantation of a self-expandable transcatheter aortic valve prosthesis in a failed Freestyle bioprothesis implanted eleven years earlier. Tips and tricks are discussed.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Stents , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 88(7): 1145-1152, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27029571

RESUMEN

BACKGROUND: Vascular complications (VC) are a serious and frequent complication of transfemoral transcatheter aortic valve implantation (TAVI) and result in increased morbidity and mortality. It has been suggested that newly developed vascular sheaths may increase the ability to perform transfemoral TAVI in patients with normal and access-limiting peripheral artery disease (PAD) and reduce vascular complications. AIMS: We sought to assess the safety and efficacy of the 19 French (F) SoloPath balloon-expandable transfemoral vascular access system in patients who underwent transfemoral TAVI at our center between 2011 and 2014. METHODS AND RESULTS: Single-center retrospective study of 90 patients who underwent transfemoral TAVI with the use of the SoloPath sheath. Patients were categorized into two groups according to a sheath to femoral artery ratio (SFAR) of less than or equal to 1.05, or greater than 1.05. Overall, the incidence of major bleeding complications was low, 4.4%. No significant differences were found in technical or procedural success rates (100% in both groups and 100% vs. 91.3; P = 0.09; respectively), total vascular complications (20.8 vs. 21.7; P = 0.92) or total bleeding complications (20.8 vs. 30.4; P = 0.36 between those with SFAR greater or less than 1.05. CONCLUSIONS: The use of the SoloPath balloon-expandable sheath is feasible and safe even in patients with SFAR > 1.05, showing no increased vascular or bleeding complications compared to patients with larger vascular access. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Angioplastia de Balón/instrumentación , Válvula Aórtica , Cateterismo Cardíaco , Cateterismo Periférico/instrumentación , Arteria Femoral , Enfermedades de las Válvulas Cardíacas/terapia , Implantación de Prótesis de Válvulas Cardíacas , Enfermedad Arterial Periférica/terapia , Dispositivos de Acceso Vascular , Anciano , Anciano de 80 o más Años , Angioplastia de Balón/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/métodos , Diseño de Equipo , Estudios de Factibilidad , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/lesiones , Arteria Femoral/fisiopatología , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemorragia/etiología , Humanos , Masculino , Enfermedad Arterial Periférica/complicaciones , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Punciones , Quebec , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Lesiones del Sistema Vascular/etiología
4.
Catheter Cardiovasc Interv ; 88(7): 1124-1133, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26891711

RESUMEN

OBJECTIVES: To evaluate the impact of baseline left ventricular (LV) function on the clinical outcomes of patients with functional mitral regurgitation (FMR) treated with MitraClip. BACKGROUND: It is unknown whether patients with significant FMR and severe LV dysfunction benefit from MitraClip. METHODS: A cohort of 77 patients with significant FMR undergoing MitraClip procedure between December 2010 and January 2015 was categorized by baseline LV ejection fraction (LVEF) into tertiles: LVEF <27% (n = 27), LVEF 27-37% (n = 25), and LVEF >37% (n = 25). We sought to evaluate the impact of LVEF on all-cause mortality at follow-up. RESULTS: There were no significant differences in baseline comorbidities, medical treatment and MR severity among tertiles of LVEF. Overall procedural success was 94%, with no differences among groups (LVEF <27%: 89%; LVEF 27-37%: 100%; LVEF >37%: 92%; P = 0.25). Median follow-up was 372 days (interquartile range: 128-627 days). MR severity improved in all three groups, as compared to baseline. There were no differences in the prevalence of MR ≤2+ on follow-up (P = 0.40). Mortality was highest in patients with LVEF <27% (41%), as compared with LVEF 27-37% (16%) and LVEF >37% (4%), P = 0.004. Patient who died had a lower baseline LVEF compared to those who survived (24.8 ± 7.7% versus 35.5 ± 13.7%, P < 0.001). An LVEF <27% was an independent predictor of mortality after adjusting for procedural success: hazard ratio 3.4 (95% CI: 1.1 to 10.0; P = 0.030). CONCLUSIONS: MitraClip is effective in FMR patients regardless of the severity of LV dysfunction. However, low baseline LVEF is associated with increased mortality, despite procedural success. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Cateterismo Cardíaco , Insuficiencia de la Válvula Mitral/terapia , Válvula Mitral/fisiopatología , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/mortalidad
5.
Catheter Cardiovasc Interv ; 85(3): 450-8, 2015 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-25115215

RESUMEN

OBJECTIVES: The objective of the present study was to assess if the presence and severity of CAD is associated with decreased LVEF recovery after TAVI. BACKGROUND: Coronary artery disease (CAD) and low left ventricular ejection fraction (LVEF) are common findings in patients undergoing transcatheter aortic valve implantation (TAVI). The impact of CAD on LVEF recovery after TAVI has not been specifically evaluated. METHODS: All patients with LVEF≤50% who underwent TAVI between March 2006 and May 2012 were included in the study. The presence and severity of coronary artery disease was measured using the Duke Myocardial Jeopardy Score (DMJS). A DMJS = 0 corresponds to patients without CAD or complete revascularization and a DMJS > 0 to those with incomplete revascularization. LVEF recovery was assessed by transthoracic echocardiography, measuring the change in LVEF from baseline to 3-months post-TAVI. Myocardial viability was evaluated in a subgroup of patients using cardiac magnetic resonance (CMR) imaging pre-TAVI. RESULTS: Fifty-six patients were included in the study. Twenty-eight patients (50%) had a DMJS > 0. At 3 months, patients with incomplete revascularization (DMJS > 0) demonstrated less LVEF recovery post-TAVI (2.0 ± 9.2% versus 11.7 ± 8.9% if DMJS = 0; P = 0.001). On multivariate analysis, DMJS and presence of significant delayed-enhancement were found to be independent predictors of LVEF recovery. Patients with incomplete revascularization exhibited a worse prognosis with higher mortality at 30-days (22.2% versus 0% if DMJS = 0; P = 0.010) and 1-year (25.9% versus 3.5% if DMJS = 0; P = 0.019). CONCLUSIONS: The present study demonstrates an independent association between incomplete revascularization and decreased LVEF recovery in patients with left ventricular dysfunction undergoing TAVI for severe aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Cateterismo Cardíaco/métodos , Enfermedad de la Arteria Coronaria/terapia , Implantación de Prótesis de Válvulas Cardíacas/métodos , Intervención Coronaria Percutánea , Volumen Sistólico , Función Ventricular Izquierda , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/efectos adversos , Distribución de Chi-Cuadrado , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/fisiopatología , Ecocardiografía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Modelos Lineales , Imagen por Resonancia Magnética , Masculino , Análisis Multivariante , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Recuperación de la Función , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
6.
JACC Case Rep ; 7: 101711, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36776792

RESUMEN

We developed humanized biosimulator to predict the risk of coronary obstruction among high-risk patients undergoing valve-in-valve (ViV) procedures. In this case, based on unchanged instantaneous wave-free ratio values measured during a ViV simulation session, the procedure was performed safely in the patient the day afterward, without coronary artery issues and with good hemodynamic results. (Level of Difficulty: Advanced.).

7.
Am J Cardiol ; 186: 11-16, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36334433

RESUMEN

In aortic stenosis (AS), left ventricular (LV) remodeling often occurs before symptom onset, and early intervention may be beneficial. Risk stratification remains challenging and identification of biomarkers may be useful. We evaluated the association between growth differentiation factor-15 (GDF-15) and soluble suppression of tumorigenicity 2 (sST2) and known markers of poor prognosis in AS. Baseline plasma GDF-15 and sST2 levels were measured in 70 patients with moderate-severe AS (aortic valve area <1.5 cm2) and preserved LV ejection fraction (>45%). Patients were categorized into "low GDF-15" versus "high GDF-15" and "low sST2" versus "high sST2" groups. Groups were compared for differences in cardiovascular risk factors, 6-minute walk test, 5 m gait speed, cognitive function (Montreal Cognitive Assessment), and echocardiographic parameters. Overall, 44% of patients were deemed asymptomatic by New York Heart Association class, 61% had severe AS (aortic valve area <1 cm2) and all patients had preserved LV ejection fraction. GDF-15 levels were not predictive of AS severity. However, high GDF-15 (>1,050 pg/ml) was associated with LV dysfunction as shown by lower indexed stroke volume (p <0.01), worse LV global longitudinal strain (p = 0.04), greater mean E/e' (p = 0.02) and indexed left atrial volume (p <0.01). It was also associated with decreased functional capacity with shorter 6-minute walk test (p = 0.01) and slower 5 m gait speed (p = 0.02). Associations between sST2 levels and markers of poor prognosis were less compelling. In this study of patients with moderate to severe AS, elevated GDF-15 levels are associated with impaired functional capacity, poorer performance on fragility testing, and LV dysfunction. In conclusion, GDF-15 may integrate these markers of adverse outcomes into a single biomarker of poor prognosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Fragilidad , Disfunción Ventricular Izquierda , Humanos , Volumen Sistólico , Función Ventricular Izquierda , Factor 15 de Diferenciación de Crecimiento , Fragilidad/complicaciones , Factores de Riesgo , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Remodelación Ventricular
8.
CJC Open ; 5(8): 611-618, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37720184

RESUMEN

Patients with new-onset left bundle branch block (LBBB) after transcatheter aortic valve implantation (TAVI) are at risk of developing delayed high-degree atrioventricular block. Management of new-onset LBBB post-TAVI remains controversial. In the Comparison of a Clinical Monitoring Strategy Versus Electrophysiology-Guided Algorithmic Approach in Patients With a New LBBB After TAVI (COME-TAVI) trial, consenting patients with new-onset LBBB that persists on day 2 after TAVI, meeting exclusion/inclusion criteria, are randomized to an electrophysiological study (EPS)-guided approach or 30-day electrocardiographic monitoring. In the EPS-guided approach, patients with a His to ventricle (HV) interval ≥ 65 ms undergo permanent pacemaker implantation. Patients randomized to noninvasive monitoring receive a wearable continuous electrocardiographic recording and transmitting device for 30 days. Follow-up will be performed at 3, 6, and 12 months. The primary endpoint is a composite outcome designed to capture net clinical benefit. The endpoint incorporates major consequences of both strategies in patients with new-onset LBBB after TAVI, as follows: (i) sudden cardiac death; (ii) syncope; (iii) atrioventricular conduction disorder requiring a pacemaker (for a class I or IIa indication); and (iv) complications related to the pacemaker or EPS. The trial incorporates a Bayesian design with a noninformative prior, outcome-adaptive randomization (initially 1:1), and 2 prespecified interim analyses once 25% and 50% of the anticipated number of primary endpoints are reached. The trial is event-driven, with an anticipated upper limit of 452 patients required to reach 77 primary outcome events over 12 months of follow-up. In summary, the aim of this Bayesian multicentre randomized trial is to compare 2 management strategies in patients with new-onset LBBB post-TAVI-an EPS-guided approach vs noninvasive 30-day monitoring. Trial registration number: NCT03303612.


Les patients chez qui un bloc de branche gauche (BBG) est récemment apparu à la suite de l'implantation valvulaire aortique par cathéter (IVAC) présentent un risque de bloc auriculoventriculaire de haut degré tardif. La prise en charge d'un BBG récemment apparu après une IVAC demeure controversée. Dans le cadre de l'essai COME-TAVI (Comparison of a ClinicalMonitoring Strategy VersusElectrophysiology-Guided Algorithmic Approach in Patients With a New LBBB AfterTAVI, ou comparaison d'une stratégie de surveillance clinique, par rapport à une approche guidée par étude électrophysiologique et fondée sur un algorithme, chez des patients présentant un BBG d'apparition récente à la suite d'une IVAC), des patients qui présentent un BBG d'apparition récente persistant le 2e jour après une IVAC, qui répondent aux critères d'admissibilité et qui ont donné leur consentement sont répartis aléatoirement pour être suivis à l'aide d'une approche guidée par une étude électrophysiologique (EEP) ou faire l'objet d'une surveillance électrocardiographique d'une durée de 30 jours. Un stimulateur cardiaque est implanté chez les patients du groupe de l'EEP dont l'intervalle HV (temps de conduction dans le tronc du faisceau de His jusqu'aux ventricules) est ≥ 65 ms. Les patients du groupe de surveillance non invasive reçoivent un dispositif portable d'enregistrement et de transmission continue de données électrocardiographiques pour une période de 30 jours. Le suivi sera réalisé aux 3e, 6e et 12e mois. Le critère d'évaluation principal est un paramètre composite conçu afin de saisir le bienfait clinique net. Il comprend les conséquences majeures des deux stratégies chez les patients présentant un BBG d'apparition récente après une IVAC, comme suit : (i) mort subite d'origine cardiaque; (ii) syncope; (iii) trouble de la conduction auriculoventriculaire nécessitant la pose d'un stimulateur cardiaque (pour une indication de classe I ou IIa); et (iv) complications relatives au stimulateur cardiaque ou à l'EEP. L'essai intègre une conception bayésienne avec une répartition aléatoire (dans un rapport initial de 1:1) antérieure non informative adaptée aux résultats et deux analyses intermédiaires définies au préalable lorsque 25 % et 50 % du nombre anticipé des critères d'évaluation principaux seront atteints. L'essai est axé sur les événements, et la limite supérieure anticipée pour atteindre 77 événements relatifs aux critères d'évaluation principaux sur 12 mois de suivi est de 452 patients. En résumé, l'objectif de cet essai bayésien multicentrique à répartition aléatoire est de comparer deux stratégies de prise en charge de patients présentant un BBG d'apparition récente après une IVAC, soit une approche guidée par une EEP, par rapport à une surveillance non invasive de 30 jours. Trial registration number: NCT03303612.

9.
Europace ; 14(5): 745-51, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22183747

RESUMEN

AIMS: ß-radiation is a novel potential energy source for the creation of myocardial lesions. While the feasibility of delivering ß-radiation via a deflectable transvenous catheter has been described, dose effects and the time course of histopathological changes have not been previously assessed. The purpose of this study was to characterize pathological aspects of cardiac lesions induced by ß-radiation in an animal model at various stages of evolution and in response to different dose exposures. METHODS AND RESULTS: Nine dogs and one pig were studied. The cavotricuspid isthmus, antrum of pulmonary veins (PVs), and mitral isthmus were irradiated (25, 50, 75, or 100 Gy) with strontium-yttrium-90, delivered via a deflectable catheter (cavotricuspid isthmus and mitral isthmus) or a double-loop catheter (antrum of PVs). Eighteen lesions were created. Animals were sacrificed at 2 weeks, 1 month, 3 months, or 6 months. Lesions were processed for morphometric histopathological analyses. Over the first month, lesions were characterized by inflammation, haemorrhage, and myocyte necrosis. Thereafter, fibrotic replacement was predominant. Transmurality of lesions was observed in 50% of cases, with no dose-response effect (P = 0.976). Surface fibrin thrombus was present in 50% of cases and was essentially limited to lesions assessed within the first month. No neighbouring injury or pulmonary venous stenosis was observed. CONCLUSIONS: Atrial lesions created by ß-radiation are characterized by an inflammatory phase with surface fibrin thrombosis during the first month and replacement fibrosis thereafter. No appreciable dose-response effect was noted within the 25-100 Gy range tested.


Asunto(s)
Partículas beta/efectos adversos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Corazón/efectos de la radiación , Traumatismos por Radiación/patología , Animales , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Perros , Relación Dosis-Respuesta en la Radiación , Atrios Cardíacos/patología , Atrios Cardíacos/efectos de la radiación , Atrios Cardíacos/cirugía , Humanos , Modelos Animales , Miocardio/patología , Venas Pulmonares/patología , Venas Pulmonares/efectos de la radiación , Venas Pulmonares/cirugía , Radioisótopos de Estroncio/efectos adversos , Porcinos , Radioisótopos de Itrio/efectos adversos
10.
Can J Cardiol ; 38(10 Suppl1): S54-S65, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-33383168

RESUMEN

The prevalence of mitral valve disease has evolved over the past 5 decades from primarily a disease of rheumatic origin to a disease affecting the aging population that encompasses a range of phenotypes from rheumatic mitral stenosis, degenerative mitral regurgitation, and degenerative mitral valve calcification to secondary mitral regurgitation. A reflection on the history of therapy for mitral valve disease is an expedition that follows the birth and development of structural heart intervention from the first percutaneous balloon mitral valvuloplasty to innovative technologies for transcatheter mitral valve repair and replacement. This review will lead you along this journey, pause to acknowledge the feats accomplished, and reflect on the road that lies ahead.


Asunto(s)
Valvuloplastia con Balón , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Estenosis de la Válvula Mitral , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/cirugía , Resultado del Tratamiento
11.
JACC Case Rep ; 4(19): 1277-1282, 2022 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-36406923

RESUMEN

Transcatheter aortic valve replacement in surgical aortic valve is a safe and effective procedure to treat patients with failed bioprosthetic surgical valves at high risk for reoperation. Performing bioprosthetic valve fracture has been shown to improve postprocedural hemodynamics of TAVR in surgical aortic valve replacement. However, specific complications related to valve fracture are becoming more common. (Level of Difficulty: Advanced.).

12.
Catheter Cardiovasc Interv ; 76(7): 1022-5, 2010 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-20518005

RESUMEN

An 80-year old nun with severe calcific aortic stenosis and a bicuspid aortic valve was referred for transcatheter aortic valve implantation. She was declined for conventional surgery on the basis of poor left ventricular function, frailty, and a logistic EuroSCORE of 29.66. A 29-mm Medtronic-Corevalve bioprosthesis was implanted by transfemoral route. The inflow portion of the stent frame was grossly underexpanded. However, aortic valve area at 1.3 cm(2) was more than satisfactory for a body surface area of 1.29 m(2) (indexed area 1.0 cm(2)/m(2), peak gradient 23, and mean 16 mmHg). There was an early sustained improvement in New York Heart Association (NYHA) status, and there was no change in valvular function at 2 year follow-up. This case highlights that gross underexpansion of the Medtronic-Corevalve stent frame is compatible with good bioprosthetic function and excellent symptomatic recovery.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/anomalías , Calcinosis/terapia , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Femenino , Arteria Femoral , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica , Humanos , Diseño de Prótesis , Recuperación de la Función , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Ultrasonografía , Función Ventricular Izquierda
13.
Cardiovasc Revasc Med ; 20(3): 228-234, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30075958

RESUMEN

BACKGROUND: Scaffold thromboses (ST) and adverse events and have been associated with bioresorbable vascular scaffolds (BVS) at long-term, but their mechanism remains unclear. We sought to evaluate patient and lesion characteristics associated with mid- to long-term outcomes in patients treated with BVS. METHODS: This is an observational single-center, single-arm, retrospective study evaluating the performance of BVS in an all-comer population, including complex lesions (chronic total occlusions, long lesions), small vessels, and acute coronary syndromes (ACS). RESULTS: From May 2013 to June 2015, we included 482 patients (580 lesions) that were treated with BVS implantation including 71.2% treated for ACS in the present analysis. Mean follow-up period was 816.2 ±â€¯242.6 days. The primary endpoint was device oriented cardiac events (DOCE), defined as a composite of target-lesion revascularization (TLR), ST, target vessel myocardial infarction (TVMI) and cardiac death. Using Kaplan-Meier methods, the DOCE and ST rates at 36 months were 9.4% and 2.3%, respectively. No ST occurred between 2 and 3 years and ST occurred after 3 years, in one patient. Using multivariate analysis, ACS was the only significant predictor of lower rates of DOCE (p = 0.04, HR: 0.47, 95% CI: 0.23-0.96). CONCLUSIONS: In this large all-comers real-world cohort, lesions treated with BVS had non-negligible rates of DOCE and ST, in line with previous published randomized trials. The occurrence of very late event was very low after 24 months. ACS patients had lower rates of DOCE.


Asunto(s)
Implantes Absorbibles , Síndrome Coronario Agudo/terapia , Enfermedad de la Arteria Coronaria/terapia , Oclusión Coronaria/terapia , Intervención Coronaria Percutánea/instrumentación , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/mortalidad , Síndrome Coronario Agudo/fisiopatología , Anciano , Enfermedad Crónica , Toma de Decisiones Clínicas , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/fisiopatología , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/mortalidad , Oclusión Coronaria/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Selección de Paciente , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
14.
Echocardiography ; 25(8): 840-8, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18476979

RESUMEN

Percutaneous aortic valve replacement (PAVR) is an emerging therapy for nonsurgical patients with severe aortic stenosis (AS). We examined the role of transesophageal echocardiography (TEE) in PAVR. TEE was used initially to assess the native valve and aortic root, and served as a guide during PAVR. Following prosthetic valve deployment, TEE was used to assess valve function. Eleven patients aged 82 +/- 10 years with NYHA III-IV underwent PAVR. Periprocedural TEE gave immediate information on prosthetic position and function, LV function, mitral regurgitation, pericardium, and thoracic aorta anatomy. There was excellent visual agreement between fluoroscopic and TEE images of prosthetic positioning and deployment. TEE facilitated the detection and management of procedure-related complications. Compared with pre-PAVR, AV area (0.56 +/- 0.19 cm(2) vs. 1.3 +/- 0.4 cm(2); P < 0.001) and LVEF (49 +/- 17% vs. 56 +/- 11%; P < 0.001) increased. TEE provides key anatomical and functional information, and serves as a diagnostic guide for complications, which may arise during PAVR.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía Transesofágica/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Cirugía Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
15.
J Med Econ ; 21(11): 1091-1095, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30099924

RESUMEN

BACKGROUND: Vascular complications are an important complication of transcatheter aortic valve implantation and are associated with increased morbidity and mortality as well as cost. The Solopath device is an expandable vascular access system that has previously been shown to be associated with lower rates of vascular complications. This study sought to evaluate the impact of the use of this system on vascular complications and costs in a decision model analysis. METHODS: A cost-consequence analysis was undertaken utilizing event rate data from the PARTNER trials and a published retrospective analysis of the Solopath device. The decision model estimated costs and benefits in a hypothetical cohort of patients with aortic stenosis undergoing TAVI using either a standard sheath or Solopath. The modeled analysis compared the occurrence of vascular complications and mortality at 30 days and 1 year using TreeAge Pro. RESULTS: The decision model demonstrated that use of the Solopath sheath resulted in 36 fewer major vascular complications, three fewer deaths at 30 days, and five fewer deaths at 1 year, resulting in a discounted cost savings of $846 CDN. Results were sensitive to decreasing rates of vascular complications with newer generation devices, however maintained modest cost-savings. CONCLUSIONS: Reduction in vascular complications is an important part of improving care for TAVI patients. The Solopath vascular access device offers an alternative to standard sheaths with a potential reduction in complications and cost-savings.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/economía , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Técnicas de Apoyo para la Decisión , Gastos en Salud , Recursos en Salud/estadística & datos numéricos , Humanos , Modelos Econométricos , Estudios Retrospectivos
16.
Circulation ; 114(8): 798-806, 2006 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-16908773

RESUMEN

BACKGROUND: The use of the Endeavor stent might reduce restenosis and stent thrombosis at 9 months. METHODS AND RESULTS: Patients (n = 1197) treated for single coronary artery stenosis were enrolled in a prospective, randomized, double-blind study and randomly assigned to receive the Endeavor zotarolimus-eluting phosphorylcholine polymer-coated stent (n = 598) or the same bare metal stent but without the drug or the polymer coating (n = 599). The 2 groups were well matched in baseline characteristics. Diabetes was present in 20.1% of patients; the mean reference vessel diameter was 2.75 mm; and the mean lesion length was 14.2 mm. The primary end point of target vessel failure at 9 months was reduced from 15.1% with the bare metal stent to 7.9% with the Endeavor (P = 0.0001), and the rate of major adverse cardiac events was reduced from 14.4% with the bare metal stent to 7.3% with the Endeavor (P = 0.0001). Target lesion revascularization was 4.6% with Endeavor compared with 11.8% with the bare metal stent (P = 0.0001). The rate of stent thrombosis was 0.5% with the Endeavor, which was not significantly different from 1.2% with the bare metal stent. In 531 patients submitted to angiographic follow-up, late loss was reduced from 1.03 +/- 0.58 to 0.61 +/- 0.46 (P < 0.001) in stent and from 0.72 +/- 0.61 to 0.36 +/- 0.46 (P < 0.001) in segment. The rate of in-segment restenosis was reduced from 35.0% to 13.2% with Endeavor (P < 0.0001). There was no excessive edge stenosis, aneurysm formation, or late acquired malapposition by intravascular ultrasound imaging. Differences in clinical outcome were maintained at 12 and 24 months (P < 0.0001). CONCLUSIONS: Compared with bare metal stents, the Endeavor stent is safe and reduces the rates of clinical and angiographic restenosis at 9, 12, and 24 months.


Asunto(s)
Antibacterianos/uso terapéutico , Enfermedad Coronaria/tratamiento farmacológico , Enfermedad Coronaria/cirugía , Sirolimus/análogos & derivados , Stents , Anciano , Antibacterianos/administración & dosificación , Cápsulas , Cateterismo Cardíaco , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Método Doble Ciego , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sirolimus/administración & dosificación , Sirolimus/uso terapéutico
18.
J Med Econ ; 20(1): 82-90, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27552378

RESUMEN

BACKGROUND: Mitral regurgitation (MR) is a common valvular heart disorder requiring intervention once it becomes severe. Transcatheter mitral repair with the MitraClip device is a safe and effective therapy for selected patients denied surgery. The authors sought to evaluate the clinical outcomes and economic impact of this therapy compared to medical management in heart-failure patients with symptomatic mitral regurgitation. METHODS AND RESULTS: The study was comprised of two phases; an observational study of patients with heart failure and mitral regurgitation treated with either medical therapy or the MitraClip, and an economic model. Results of the observational study were used to estimate parameters for the decision model, which estimated costs, and benefits in a hypothetical cohort of patients with heart failure and moderate-to-severe mitral regurgitation treated with either standard medical therapy or MitraClip. The cohort of patients treated with the MitraClip was propensity matched to a population of heart failure patients, and their outcomes compared. At a mean follow-up of 22 months, all-cause mortality was 21% in the MitraClip cohort and 42% in the medical management cohort (p = .007). The decision model demonstrated that MitraClip increased life expectancy from 1.87-3.60 years and quality-adjusted life years (QALY) from 1.13-2.76 years. The incremental cost was $52,500 Canadian dollars, corresponding to an incremental cost-effectiveness ratio (ICER) of $32,300.00 per QALY gained. Results were sensitive to the survival benefit. CONCLUSION: In heart failure patients with symptomatic moderate-severe mitral regurgitation, therapy with the MitraClip is associated with superior survival and is cost-effective compared to medical therapy.


Asunto(s)
Costos de la Atención en Salud , Insuficiencia Cardíaca/cirugía , Implantación de Prótesis de Válvulas Cardíacas/economía , Válvula Mitral/cirugía , Resultado del Tratamiento , Anciano , Canadá , Análisis Costo-Beneficio , Femenino , Costos de la Atención en Salud/estadística & datos numéricos , Recursos en Salud/economía , Recursos en Salud/estadística & datos numéricos , Insuficiencia Cardíaca/economía , Humanos , Masculino , Persona de Mediana Edad , Modelos Económicos , Estudios Prospectivos , Años de Vida Ajustados por Calidad de Vida
20.
EuroIntervention ; 12(8): e1039-e1046, 2016 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-27159659

RESUMEN

AIMS: Our aim was to evaluate the long-term device performance and clinical outcomes of patients with symptomatic, severe aortic valve stenosis (AS) who underwent transcatheter aortic valve implantation (TAVI) with the CoreValve bioprosthesis. METHODS AND RESULTS: The CoreValve CE Pivotal Study was a prospective, multicentre, single-arm TAVI trial using the CoreValve system. Valve performance, patient quality of life (QoL), New York Heart Association (NYHA) class, and mortality at four years were analysed in 126 patients (mean age 82.4 years, 42.9% male, mean logistic EuroSCORE 23.4%) with severe AS. Mean aortic valve gradient decreased from 46.9±16.1 mmHg at baseline to 9.8±4.1 mmHg at discharge and to 7.8±2.7 mmHg at four years. Mean effective orifice area increased from 0.7±0.2 cm2 to 1.8±0.4 cm2 after TAVI and was 1.6±0.5 cm2 at four years. There were no reports of structural valve deterioration or valve migration. There was sustained improvement in QoL and NYHA class in surviving patients. All-cause and cardiac survival was 45.3% and 62.6%, respectively, at four years. CONCLUSIONS: The CoreValve bioprosthesis demonstrates long-term durability, stable haemodynamic function, and no evidence of structural deterioration. Most surviving patients continued to have improved NYHA class and QoL at four years.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Falla de Prótesis , Índice de Severidad de la Enfermedad , Tasa de Supervivencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA