Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur Radiol ; 31(5): 3090-3097, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33123792

RESUMEN

OBJECTIVE: Assessment of lung development and maturity is of utmost importance in prenatal counseling. Blood oxygen level-dependent (BOLD) effect MRI was developed for functional evaluations of organs. To date, no data are available in fetal lungs and nothing is known about the existence of a BOLD effect in the lungs. The aim of our study was to evaluate if a BOLD response could be detected in fetal lungs. MATERIALS AND METHODS: From January 2014 to December 2016, 38 healthy pregnant women were prospectively enrolled. After a routine scan on a 1.5-T MRI device (normoxic period), maternal hyperoxia was induced for 5 min before the BOLD sequence (hyperoxic period). R2* was evaluated by fitting average intensity of the signal, both for normoxic (norm) and hyperoxic (hyper) periods. RESULTS: A significant BOLD response was observed after maternal hyperoxia in the lungs with a mean R2* decrease of 12.1 ± 2.5% (p < 0.001), in line with the placenta response with a mean R2* decrease of 19.2 ± 5.9% (p < 0.0001), confirming appropriate oxygen uptake. Conversely, no significant BOLD effect was observed for the brain nor the liver with a mean ∆R2* of 3.6 ± 3.1% (p = 0.64) and 2.8 ± 3.7% (p = 0.23). CONCLUSION: This study shows for the first time in human that a BOLD response can be observed in the normal fetal lung despite its prenatal "non-functional status." If confirmed in congenital lung and chest malformations, this property could be used in addition to the lung volume for a better prediction of postnatal respiratory status. KEY POINTS: • Blood oxygen level-dependent (BOLD) effect MRI was developed for functional evaluations of organs and could have interesting implications for the fetal organs. • Assessment of lung development is of utmost importance in prenatal counseling, but to date no data are available in fetal lungs. • BOLD response can be observed in the normal fetal lung opening the way to studies on fetus with pathological lungs.


Asunto(s)
Hiperoxia , Oxígeno , Femenino , Feto/diagnóstico por imagen , Humanos , Hiperoxia/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética , Embarazo
2.
PLoS One ; 14(3): e0213459, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30845221

RESUMEN

OBJECTIVES: To assess the influence of gray-level discretization on inter- and intra-observer reproducibility of texture radiomics features on clinical MR images. MATERIALS AND METHODS: We studied two independent MRI datasets of 74 lacrymal gland tumors and 30 breast lesions from two different centers. Two pairs of readers performed three two-dimensional delineations for each dataset. Texture features were extracted using two radiomics softwares (Pyradiomics and an in-house software). Reproducible features were selected using a combination of intra-class correlation coefficient (ICC) and concordance and coherence coefficient (CCC) with 0.8 and 0.9 as thresholds, respectively. We tested six absolute and eight relative gray-level discretization methods and analyzed the distribution and highest number of reproducible features obtained for each discretization. We also analyzed the number of reproducible features extracted from computer simulated delineations representative of inter-observer variability. RESULTS: The gray-level discretization method had a direct impact on texture feature reproducibility, independent of observers, software or method of delineation (simulated vs. human). The absolute discretization consistently provided statistically significantly more reproducible features than the relative discretization. Varying the bin number of relative discretization led to statistically significantly more variable results than varying the bin size of absolute discretization. CONCLUSIONS: When considering inter-observer reproducible results of MRI texture radiomics features, an absolute discretization should be favored to allow the extraction of the highest number of potential candidates for new imaging biomarkers. Whichever the chosen method, it should be systematically documented to allow replicability of results.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Mama/patología , Simulación por Computador , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA