Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 99(5): 1582-1589, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35043554

RESUMEN

OBJECTIVES: We sought to assess the impact of echocardiographic and hemodynamic grading of paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI) on the prediction of 5-year mortality. PVL after TAVI is known to influence outcome after TAVI. Yet, present available data of long-term outcomes and especially the comparison of different modalities for measurement of PVL is little. METHODS: We performed a retrospective single-center cohort study and compared the prognostic value of echocardiographic PVL grading as well as the aortic regurgitation index (ARI) pre- and post-TAVI. Univariable and multivariable Cox proportional regression analysis generated hazard ratios for mortality. RESULTS: A total of 464 patients underwent TAVI at our center between August 2012 and Decemebr 2014, with self-expandable CoreValve (11%) or balloon-expandable Sapien XT (47.4%) and Sapien 3 (41.6) valves. Overall 5-year mortality was 52.4% (243/464). Echocardiographic classes of PVL at discharge showed a significant (p = 0.002) association with 5-year mortality, mild PVL remained as an independent predictor for 5-year mortality in multivariable analysis (hazard ratio: 1.642 [95% confidence interval: 1.235-2.182]; p = 0.001). Grades of PVL as assessed during the procedure by ARI (below the previously defined cut-off of 25) did not show a significant association with 5-year mortality (p = 0.417 and p = 0.995, respectively). CONCLUSIONS: Even mild PVL assessed by echocardiography was an independent predictor for 5-year survival, whereas hemodynamic measurements did not help to identify PVLs that are relevant to 5-year survival.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios de Cohortes , Ecocardiografía , Hemodinámica , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 91(6): E56-E63, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-29105984

RESUMEN

OBJECTIVES: We sought to assess angiographic, echocardiographic and hemodynamic grading of paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI) with respect to prediction of 1-year mortality. BACKGROUND: Meaningful criteria for the severity of PVL are needed to allow intraprocedural guidance and patient management after TAVI. METHODS: We pooled the prospective TAVI databases of 2 German centers. During TAVI, PVL was assessed angiographically and by the aortic regurgitation index (ARI). ARI was calculated as ratio of the gradient between diastolic blood pressure and left ventricular end-diastolic pressure to systolic blood pressure times hundred. In addition, we performed transthoracic echocardiography before discharge. RESULTS: A total of 723 patients undergoing TAVI with self-expandable (20.9%) or balloon-expandable (79.1%) valves were included. Grades of PVL as assessed during the procedure by angiography or ARI (below the previously defined cut-off of 25) did not show a significant association with 1-year mortality (P = 0.312 and 0.776, respectively). One-year mortality was 15.7% (39/249) in patienths with an ARI < 25 and 16.5% (71/430) in patients with an ARI ≥ 25. Echocardiographic classes of PVL at discharge showed a significant (P = 0.029) association with 1-year mortality, which was 11.5% (37/322) in patients with no/trace PVL, 18.0% (62/345) in patients with mild PVL and 23.1% (6/26) in patients with more than mild PVL. These findings prevailed after multivariable adjustment. CONCLUSIONS: ARI did not help identify PVLs that are relevant to 1-year survival. Angiographic assessment during the procedure was less predictive than echocardiographic assessment before discharge.


Asunto(s)
Angiografía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Ecocardiografía , Hemodinámica , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón , Bases de Datos Factuales , Femenino , Alemania/epidemiología , Prótesis Valvulares Cardíacas , Humanos , Incidencia , Masculino , Valor Predictivo de las Pruebas , Diseño de Prótesis , Reproducibilidad de los Resultados , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA