Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

País/Región como asunto
Intervalo de año de publicación
1.
Am J Cardiol ; 214: 8-17, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38104756

RESUMEN

This study aimed to evaluate the incidence and clinical implications of myocardial injury, as determined by cardiac biomarker increase, in patients who underwent mitral bioprosthesis dysfunction treatment with transcatheter mitral valve replacement (TMVR) versus surgical mitral valve replacement reoperation (SMVR-REDO). Between 2014 and 2023, 310 patients with mitral bioprosthesis failure were included (90 and 220 patients for TMVR and SMVR-REDO, respectively). Multivariable analysis and propensity score matching were performed to adjust for the intergroup differences in baseline characteristics. Creatinine kinase-MB (CK-MB) and cardiac troponin I (cTn) were collected at baseline and 6 to 12, 24, 48, and 72 hours after intervention. The cardiac biomarkers values were evaluated in relation to their reference values. The outcomes were determined according to the Mitral Valve Academic Research Consortium criteria. CK-MB and cTn increased above the reference level in almost all patients after SMVR-REDO and TMVR (100% vs 94%, respectively), with the peak occurring within 6 to 12 hours. SMVR-REDO was associated with a two- to threefold higher increase in cardiac biomarkers. After 30 days, the mortality rates were 13.3% in the TMVR and 16.8% in the SMVR-REDO groups. At a median follow-up of 19 months, the mortality rates were 21.1% in the TMVR and 17.7% in the SMVR-REDO groups. Left ventricular ejection fraction, estimated glomerular filtration rate, CK-MB, and cTn were predictors of mortality. In conclusion, some degree of myocardial injury occurred systematically after the treatment of mitral bioprosthetic degeneration, especially after SMVR, and higher CK-MB and cTn levels were associated with increased cumulative late mortality, regardless of the approach.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/cirugía , Reoperación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Volumen Sistólico , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Resultado del Tratamiento , Función Ventricular Izquierda , Enfermedades de las Válvulas Cardíacas/cirugía , Biomarcadores , Cateterismo Cardíaco/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos
2.
Arq Bras Cardiol ; 120(11): e20220496, 2023 Nov.
Artículo en Portugués, Inglés | MEDLINE | ID: mdl-38126512

RESUMEN

BACKGROUND: Central Illustration : Percutaneous Strategies in Structural Heart Diseases: Focus on Chronic Heart Failure Transcatheter devices for monitoring and treating advanced chronic heart failure patients. PA: pulmonary artery; LA: left atrium; AFR: atrial flow regulator; TASS: Transcatheter Atrial Shunt System; VNS: vagus nerve stimulation; BAT: baroreceptor activation therapy; RDN: renal sympathetic denervation; F: approval by the American regulatory agency (FDA); E: approval by the European regulatory agency (CE Mark). BACKGROUND: Innovations in devices during the last decade contributed to enhanced diagnosis and treatment of patients with cardiac insufficiency. These tools progressively adapted to minimally invasive strategies with rapid, widespread use. The present article focuses on actual and future directions of device-related diagnosis and treatment of chronic heart failure.


Asunto(s)
Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/terapia , Simpatectomía , Atrios Cardíacos , Riñón
3.
Arq Bras Cardiol ; 120(4): e20210462, 2023.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-37132671

RESUMEN

BACKGROUND: Major advances have been seen in techniques and devices for performing percutaneous coronary interventions (PCIs) for chronic total occlusions (CTOs), but there are limited real-world practice data from developing countries. OBJECTIVES: To report clinical and angiographic characteristics, procedural aspects, and clinical outcomes of CTO PCI performed at dedicated centers in Brazil. METHODS: Included patients underwent CTO PCI at centers participating in the LATAM CTO Registry, a Latin American multicenter registry dedicated to prospective collection of these data. Inclusion criteria were procedures performed in Brazil, age 18 years or over, and presence of CTO with PCI attempt. CTO was defined as a 100% lesion in an epicardial coronary artery, known or estimated to have lasted at least 3 months. RESULTS: Data on 1196 CTO PCIs were included. Procedures were performed primarily for angina control (85%) and/or treatment of moderate/severe ischemia (24%). Technical success rate was 84%, being achieved with antegrade wire approaches in 81% of procedures, antegrade dissection and re-entry in 9%, and retrograde approaches in 10%. In-hospital adverse cardiovascular events occurred in 2.3% of cases, with a mortality rate of 0.75%. CONCLUSIONS: CTOs can be treated effectively in Brazil by using PCI, with low complication rates. The scientific and technological development observed in this area in the past decade is reflected in the clinical practice of dedicated Brazilian centers.


FUNDAMENTO: Tem sido observado um grande avanço nas técnicas e nos dispositivos para a realização de intervenções coronárias percutâneas (ICP) em oclusões totais coronarianas crônicas (OTC), mas existem poucos dados da prática do mundo real em países em desenvolvimento. OBJETIVOS: Relatar as características clínicas e angiográficas, os aspectos dos procedimentos e os resultados clínicos da ICP de OTC em centros dedicados a esse procedimento no Brasil. MÉTODOS: Os pacientes incluídos foram submetidos à ICP de OTC em centros participantes do LATAM CTO Registry, um registro multicêntrico latino-americano dedicado à coleta prospectiva desses dados. Os critérios de inclusão foram procedimentos realizados no Brasil, idade acima de 18 anos e presença de OTC com tentativa de ICP. A definição de OTC foi lesão de 100% em uma artéria coronária epicárdica, conhecida ou estimada como tendo pelo menos 3 meses de evolução. RESULTADOS: Foram incluídos dados de 1.196 ICPs de OTC. Os procedimentos foram realizados principalmente para controle da angina (85%) e/ou tratamento de uma grande área isquêmica (24%). A taxa de sucesso técnico foi de 84% e foi alcançada com técnicas de fios anterógrados em 81%, dissecção/reentrada anterógrada em 9% e retrógrada em 10% dos procedimentos. Os eventos cardiovasculares adversos intra-hospitalares ocorreram em 2,3% dos casos, sendo a mortalidade de 0,75%. CONCLUSÕES: As OTC podem ser tratadas no Brasil por intervenção coronária percutânea de forma efetiva e com baixas taxas de complicações. O desenvolvimento científico e tecnológico observado nessa área na última década reflete-se na prática clínica de centros brasileiros dedicados a essa técnica.


Asunto(s)
Oclusión Coronaria , Intervención Coronaria Percutánea , Humanos , Adolescente , Brasil , Oclusión Coronaria/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Intervención Coronaria Percutánea/métodos , Enfermedad Crónica , Sistema de Registros
4.
J Cardiol Cases ; 25(2): 61-64, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35079298

RESUMEN

Coronary obstruction is an uncommon and severe complication after a transcatheter aortic valve replacement (TAVR), that occurs during the procedure in the vast majority of patients. In the present case even in the absence of classic risk factors, an acute coronary syndrome occurred one day after TAVR. Selective angiography revealed a severe left main ostium obstruction by the bulky native leaflet calcification. This is the first case of delayed presentation of coronary obstruction with a transfemoral balloon-expandable valve using the Inovare bioprosthesis (Braile Biomedica, Brazil). In addition, after drug-eluting stent placement in the left main coronary, intravascular ultrasound revealed severe stent underexpansion, so that a second layer of a bare-metal stent and high-pressure balloon post-dilatation was necessary to improve the final result. The patient was discharged after 7 days, and at the 6-month follow-up remained asymptomatic. .

5.
Arq Bras Cardiol ; 118(6): 1085-1096, 2022.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-35703645

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a worldwide adopted procedure with rapidly evolving practices. Regional and temporal variations are expected to be found. OBJECTIVE: To compare TAVR practice in Latin America with that around the world and to assess its changes in Latin America from 2015 to 2020. METHODS: A survey was applied to global TAVR centers between March and September 2015, and again to Latin-American centers between July 2019 and January 2020. The survey consisted of questions addressing: i) center's general information; ii) pre-TAVR evaluation; iii) procedural techniques; iv) post-TAVR management; v) follow-up. Answers from the 2015 survey of Latin-American centers (LATAM15) were compared with those of other centers around the world (WORLD15) and with the 2020 updated Latin-American survey (LATAM20). A 5% level of significance was adopted for statistical analysis. RESULTS: 250 centers participated in the 2015 survey (LATAM15=29; WORLD15=221) and 46 in the LATAM20. Combined centers experience accounted for 73 707 procedures, with WORLD15 centers performing, on average, 6- and 3-times more procedures than LATAM15 and LATAM20 centers, respectively. LATAM centers performed less minimalistic TAVR than WORLD15 centers, but there was a significant increase in less invasive procedures after 5 years in Latin-American centers. For postprocedural care, a lower period of telemetry and maintenance of temporary pacing wire, along with less utilization of dual antiplatelet therapy was observed in LATAM20 centers. CONCLUSION: Despite still having a much lower number of procedures, many aspects of TAVR practice in Latin-American centers have evolved in recent years, followingthe trend observed in developed country centers.


FUNDAMENTO: Implante transcateter de valva aórtica (TAVI) é um procedimento adotado em todo o mundo e suas práticas evoluem rapidamente. Variações regionais e temporais são esperadas. OBJETIVO: Comparar a prática de TAVI na América Latina com aquela no resto do mundo e avaliar suas mudanças na América Latina de 2015 a 2020. MÉTODO: A pesquisa foi realizada em centros de TAVI em todo o mundo entre março e setembro de 2015, e novamente nos centros latino-americanos entre julho de 2019 e janeiro de 2020. As seguintes questões foram abordadas: i) informação geral sobre os centros; ii) avaliação pré-TAVI; iii) técnicas do procedimento; iv) conduta pós-TAVI; v) seguimento. As respostas da pesquisa dos centros latino-americanos em 2015 (LATAM15) foram comparadas àquelas dos centros no resto do mundo (WORLD15) e ainda àquelas da pesquisa dos centros latino-americanos de 2020 (LATAM20). Adotou-se o nível de significância de 5% na análise estatística. RESULTADOS: 250 centros participaram da pesquisa em 2015 (LATAM15=29; WORLD15=221) e 46 na avaliação LATAM20. No total, foram 73.707 procedimentos, sendo que os centros WORLD15 realizaram, em média, 6 e 3 vezes mais procedimentos do que os centros LATAM15 e LATAM20, respectivamente. Os centros latino-americanos realizaram menor número de TAVI minimalista do que os do restante do mundo, mas aumentaram significativamente os procedimentos menos invasivos após 5 anos. Quanto à assistência pós-procedimento, observaram-se menor tempo de telemetria e de manutenção do marca-passo temporário, além de menor uso de terapia dupla antiplaquetária nos centros LATAM20. CONCLUSÃO: A despeito do volume de procedimentos ainda significativamente menor, muitos aspectos da prática de TAVI nos centros latino-americanos evoluíram recentemente, acompanhando a tendência dos centros dos países desenvolvidos.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , América Latina , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
6.
Arq Bras Cardiol ; 116(6): 1059-1069, 2021 06.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-34133587

RESUMEN

BACKGROUND: Mitral regurgitation (MR) is prevalent in patients undergoing transcatheter aortic valve implantation (TAVI). There are some controversies about the prognostic impact of MR in survival of TAVI patients. OBJECTIVE: To examine the relationship between TAVI and MR in a patient population from the Brazilian TAVI Registry. METHODS: Seven hundred and ninety-five patients from the Brazilian TAVI Registry were divided at baseline, discharge, and follow-up according to their MR grade as follows: absent/mild (AMMR) or moderate/severe (MSMR). They were subsequently regrouped according to their immediate and late changes in MR severity after TAVI as follows: no change, improved, or worsened MR. Predictors and prognostic impact on baseline as well as changes in MR severity were analyzed. Statistical significance was set at p < 0.05. RESULTS: Baseline MSMR was present in 19.3% of patients and was a predictor of increased late mortality. Immediately after TAVI, 47.4 % of cases improved to AMMR, predicted by a higher Society of Thoracic Surgeons score and a higher grade of baseline aortic regurgitation. Upon follow-up, 9.2% of cases of AMMR worsened to MSMR, whereas 36.8% of cases of MSMR improved to AMMR. Lower baseline left ventricular ejection fraction (LVEF) and improvement in LVEF at follow-up were predictors of MR improvement. Progressive worsening of MR upon follow-up was an independent predictor of higher late mortality after TAVI (p = 0.005). CONCLUSIONS: Baseline MSMR predicts late mortality after TAVI. Lower LVEF and improved LVEF at follow-up predict MR improvement after TAVI. Progressive worsening of MR severity at follow-up is an independent predictor of late mortality, which is a rare finding in the literature.


FUNDAMENTO: A regurgitação mitral (RM) é prevalente em pacientes submetidos a implante transcateter de válvula aórtica (TAVI). Há algumas controvérsias sobre o impacto prognóstico da RM na sobrevida de pacientes submetidos a TAVI. OBJETIVO: Examinar a relação entre TAVI e RM em uma população de pacientes do Registro Brasileiro de TAVI. MÉTODOS: Setecentos e noventa e cinco pacientes do Registro Brasileiro de TAVI foram divididos na linha de base, alta e acompanhamento de acordo com o grau da RM da maneira seguinte: ausente/leve (RMAL) ou moderado/grave (RMMG). Eles foram subsequentemente reagrupados de acordo com as mudanças imediatas e tardias na gravidade da RM após TAVI da maneira seguinte: RM sem mudança, melhora ou piora. Foram analisados os preditores e o impacto prognóstico na linha de base, bem como as mudanças na gravidade da RM. A significância estatística foi estabelecida em p < 0,05. RESULTADOS: RMMG basal estava presente em 19,3% dos pacientes e foi um preditor de aumento da mortalidade tardia. Imediatamente após o TAVI, 47,4% dos casos melhoraram para RMAL, previsto por uma pontuação mais alta da Society of Thoracic Surgeons e um grau mais alto de regurgitação aórtica basal. No acompanhamento, 9,2% dos casos de RMAL pioraram para RMMG, enquanto 36,8% dos casos de RMMG melhoraram para RMAL. Fração de ejeção do ventrículo esquerdo (FEVE) mais baixa na linha de base e melhora na FEVE durante o acompanhamento foram preditores de melhora da RM. Piora progressiva da RM no acompanhamento foi um preditor independente de maior mortalidade tardia após TAVI (p = 0,005). CONCLUSÕES: A RMMG na linha de base é um preditor de mortalidade tardia após TAVI. FEVE mais baixa e melhora na FEVE durante o acompanhamento são preditores de melhora da RM após TAVI. A pior progressiva da gravidade da RM durante o acompanhamento é um preditor independente de mortalidade tardia; isto é um achado raro na literatura.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Brasil , Estudios de Seguimiento , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Índice de Severidad de la Enfermedad , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
7.
Arq Bras Cardiol ; 115(3): 515-524, 2020 09.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-32491130

RESUMEN

BACKGROUND: Percutaneous intervention in patients with bioprosthetic mitral valve dysfunction is an alternative to conventional surgical treatment. OBJECTIVES: To report the first Brazilian experience with transseptal transcatheter bioprosthetic mitral valve-in-valve implantation (transseptal-TMVIV). METHODS: Patients with surgical bioprosthetic dysfunction submitted to transseptal-TMVIV in 12 Brazilian hospitals were included. The significance level adopted was p<0.05. RESULTS: From June/2016 to February/2019, 17 patients underwent transseptal-TMVIV. Their median age was 77 years (IQR,70-82) and median Society of Thoracic Surgeons predicted risk of mortality (STS-PROM) score was 8.7% (IQR,7.2-17.8). All patients had limiting symptoms of heart failure (FC≥III) and 5 (29.4%) had undergone more than one previous thoracotomy. Transseptal-TMVIV was successful in all patients. Echocardiographic assessment showed a significant reduction in mean mitral valve gradient (pre-intervention, 12±3.8 mmHg; post-intervention, 5.3±2.6 mmHg; p<0.001), in addition to an increase in mitral valve area (pre-intervention, 1.06±0.59 cm2; post-intervention, 2.18±0.36 cm2; p<0.001) sustained for 30 days. There was a significant and immediate reduction in the pulmonary artery systolic pressure, with an additional reduction in 30 days (pre-intervention, 68.9±16.4 mmHg; post-intervention, 57.7±16.5 mmHg; 30 days, 50.9±18.7 mmHg; p<0.001). During follow-up (median, 162 days; IQR, 102-411), significant clinical improvement (FC≤II) was observed in 87.5% of the patients. One patient (5.9%) had left ventricular outflow tract (LVOT) obstruction and died right after the procedure, and another died at 161 days of follow-up. CONCLUSION: The first Brazilian experience with transseptal-TMVIV shows the safety and effectivity of the new technique. The LVOT obstruction is a potentially fatal complication, reinforcing the importance of patients' selection and of procedural planning. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0).


FUNDAMENTO: A intervenção percutânea em pacientes com disfunção de prótese biológica mitral apresenta-se como uma alternativa ao tratamento cirúrgico convencional. OBJETIVO: Relatar a primeira experiência brasileira de implante transcateter de bioprótese valve-in-valve mitral via transeptal (TMVIV-via transeptal). MÉTODOS: Foram incluídos pacientes portadores de disfunção de bioprótese cirúrgica submetidos ao TMVIV-transeptal em 12 hospitais brasileiros. Foram considerados estatisticamente significativos valores de p<0,05. RESULTADOS: Entre junho/2016 e fevereiro/2019, 17 pacientes foram submetidos ao TMVIV-via transeptal. A mediana de idade foi 77 anos (IIQ,70-82), a mediana do escore STS-PROM foi 8,7% (IIQ,7,2-17,8). Todos os pacientes tinham sintomas limitantes de insuficiência cardíaca (CF≥III), tendo 5 (29,4%) sido submetidos a mais de uma toracotomia prévia. Obteve-se sucesso do TMVIV-via transeptal em todos os pacientes. A avaliação ecocardiográfica demonstrou redução significativa do gradiente médio (pré-intervenção, 12±3,8 mmHg; pós-intervenção, 5,3±2,6 mmHg; p<0,001), assim como aumento da área valvar mitral (pré-intervenção, 1,06±0,59 cm2; pós-intervenção, 2,18±0,36 cm2; p<0,001) sustentados em 30 dias. Houve redução significativa e imediata da pressão sistólica de artéria pulmonar, com redução adicional em 30 dias (pré-intervenção, 68,9±16,4 mmHg; pós-intervenção, 57,7±16,5 mmHg; 30 dias, 50,9±18,7 mmHg; p<0,001). Durante o seguimento, com mediana de 162 dias (IIQ, 102-411), observou-se marcada melhora clínica (CF≤II) em 87,5%. Um paciente (5,9%) apresentou obstrução de via de saída de ventrículo esquerdo (VSVE), evoluindo para óbito logo após o procedimento, e outro morreu aos 161 dias de seguimento.Conclusão: A primeira experiência brasileira de TMVIV-transeptal demonstra a segurança e a efetividade dessa nova técnica. A obstrução da VSVE é uma complicação potencialmente fatal, reforçando a importância da seleção dos pacientes e do planejamento do procedimento. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Anciano de 80 o más Años , Brasil , Cateterismo Cardíaco , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Diseño de Prótesis , Resultado del Tratamiento
9.
Arq. bras. cardiol ; 120(4): e20210462, 2023. tab, graf
Artículo en Portugués | LILACS-Express | LILACS | ID: biblio-1439329

RESUMEN

Resumo Fundamento Tem sido observado um grande avanço nas técnicas e nos dispositivos para a realização de intervenções coronárias percutâneas (ICP) em oclusões totais coronarianas crônicas (OTC), mas existem poucos dados da prática do mundo real em países em desenvolvimento. Objetivos Relatar as características clínicas e angiográficas, os aspectos dos procedimentos e os resultados clínicos da ICP de OTC em centros dedicados a esse procedimento no Brasil. Métodos Os pacientes incluídos foram submetidos à ICP de OTC em centros participantes do LATAM CTO Registry, um registro multicêntrico latino-americano dedicado à coleta prospectiva desses dados. Os critérios de inclusão foram procedimentos realizados no Brasil, idade acima de 18 anos e presença de OTC com tentativa de ICP. A definição de OTC foi lesão de 100% em uma artéria coronária epicárdica, conhecida ou estimada como tendo pelo menos 3 meses de evolução. Resultados Foram incluídos dados de 1.196 ICPs de OTC. Os procedimentos foram realizados principalmente para controle da angina (85%) e/ou tratamento de uma grande área isquêmica (24%). A taxa de sucesso técnico foi de 84% e foi alcançada com técnicas de fios anterógrados em 81%, dissecção/reentrada anterógrada em 9% e retrógrada em 10% dos procedimentos. Os eventos cardiovasculares adversos intra-hospitalares ocorreram em 2,3% dos casos, sendo a mortalidade de 0,75%. Conclusões As OTC podem ser tratadas no Brasil por intervenção coronária percutânea de forma efetiva e com baixas taxas de complicações. O desenvolvimento científico e tecnológico observado nessa área na última década reflete-se na prática clínica de centros brasileiros dedicados a essa técnica.


Abstract Background Major advances have been seen in techniques and devices for performing percutaneous coronary interventions (PCIs) for chronic total occlusions (CTOs), but there are limited real-world practice data from developing countries. Objectives To report clinical and angiographic characteristics, procedural aspects, and clinical outcomes of CTO PCI performed at dedicated centers in Brazil. Methods Included patients underwent CTO PCI at centers participating in the LATAM CTO Registry, a Latin American multicenter registry dedicated to prospective collection of these data. Inclusion criteria were procedures performed in Brazil, age 18 years or over, and presence of CTO with PCI attempt. CTO was defined as a 100% lesion in an epicardial coronary artery, known or estimated to have lasted at least 3 months. Results Data on 1196 CTO PCIs were included. Procedures were performed primarily for angina control (85%) and/or treatment of moderate/severe ischemia (24%). Technical success rate was 84%, being achieved with antegrade wire approaches in 81% of procedures, antegrade dissection and re-entry in 9%, and retrograde approaches in 10%. In-hospital adverse cardiovascular events occurred in 2.3% of cases, with a mortality rate of 0.75%. Conclusions CTOs can be treated effectively in Brazil by using PCI, with low complication rates. The scientific and technological development observed in this area in the past decade is reflected in the clinical practice of dedicated Brazilian centers.

10.
Arq Bras Cardiol ; 109(5): 440-447, 2017 Nov.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-29069203

RESUMEN

BACKGROUND: Left atrial appendage closure (LAAC) is an effective alternative to oral anticoagulation (OA) for the prevention of stroke in patients with non-valvular atrial fibrillation (NVAF). OBJECTIVE: To present the immediate results and late outcomes of patients submitted to LAAC and included in the Brazilian Registry of Percutaneous Left Atrial Appendage Closure. METHODS: 91 patients with NVAF, high stroke risk (CHA2DS2VASc score = 4.5 ± 1.5) and restrictions to OAC (HAS-BLED score = 3.6 ± 1.0) underwent 92 LAAC procedures using either the Amplatzer cardiac plug or the Watchman device in 11 centers in Brazil, between late 2010 and mid 2016. RESULTS: Ninety-six devices were used (1.04 device/procedure, including an additional non-dedicated device), with a procedural success rate of 97.8%. Associated procedures were performed in 8.7% of the patients. Complete LAAC was obtained in 93.3% of the successful cases. In cases of incomplete closure, no residual leak was larger than 2.5 mm. One patient needed simultaneous implantation of 2 devices. There were 7 periprocedural major (5 pericardial effusions requiring pericardiocentesis, 1 non-dedicated device embolization and 1 coronary air embolism without sequelae) and 4 minor complications. After 128.6 patient-years of follow-up there were 3 deaths unrelated to the procedure, 2 major bleedings (one of them in a patient with an unsuccessful LAAC), thrombus formation over the device in 2 cases (both resolved after resuming OAC for 3 months) and 2 strokes (2.2%). CONCLUSIONS: In this multicenter, real world registry, that included patients with NVAF and high thromboembolic and bleeding risks, LAAC effectively prevented stroke and bleeding when compared to the expected rates based on CHA2DS2VASc and HASBLED scores for this population. Complications rate of the procedure was acceptable considering the beginning of the learning curve of most of the involved operators.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Dispositivo Oclusor Septal , Accidente Cerebrovascular/prevención & control , Anciano , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Ecocardiografía Transesofágica , Femenino , Estudios de Seguimiento , Humanos , Masculino , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
11.
Arq Bras Cardiol ; 102(1): 93-6, 2014 Jan.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-24652089

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) was established as an important alternative for high-risk patients with severe aortic stenosis. However, there are few data in the literature regarding coronary obstruction, that although rare, is a potentially fatal complication. OBJECTIVE: Evaluate this complication in Brazil. METHODS: We evaluated all patients presenting coronary obstruction from the Brazilian Registry of TAVI. Main baseline and procedural characteristics, management of the complication, and clinical outcomes were collected from all patients. RESULTS: From 418 consecutive TAVI procedures, coronary obstruction occurred in 3 cases (incidence of 0.72%). All patients were women, without prior coronary artery bypass grafting (CABG), and with mean age of 85 ± 3 years, logistic EuroSCORE of 15 ± 6% and STS-PROM score of 9 ± 4%. All of the cases were performed with balloon-expandable Sapien XT prosthesis. In one patient, with pre-procedural computed tomography data, coronary arteries presented a low height and a narrow sinus of Valsalva. All patients presented with clinically significant severe maintained hypotension, immediately after valve implantation, and even though coronary angioplasty with stent implantation was successfully performed in all cases, patients died during hospitalization, being two periprocedurally. CONCLUSION: Coronary obstruction following TAVI is a rare but potentially fatal complication, being more frequent in women and with the balloon-expandable prosthesis. Anatomical factors might be related with its increased occurrence, highlighting the importance of a good pre-procedural evaluation of the patients in order to avoid this severe complication.


Asunto(s)
Bioprótesis/efectos adversos , Oclusión Coronaria/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Anciano de 80 o más Años , Angioplastia , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/efectos adversos , Stents Liberadores de Fármacos , Resultado Fatal , Femenino , Humanos , Complicaciones Posoperatorias , Factores de Riesgo , Resultado del Tratamiento
12.
Arq Bras Cardiol ; 105(2 Suppl 1): 1-105, 2015 Aug.
Artículo en Portugués | MEDLINE | ID: mdl-26375058
14.
Arq Bras Cardiol ; 93(4): 409-17, 401-9, 2009 Oct.
Artículo en Inglés, Portugués, Español | MEDLINE | ID: mdl-19936462

RESUMEN

BACKGROUND: Male patients, aged over 65 years and with no history of heart disease, need the following tests as a preoperative evaluation: blood count, electrocardiogram and X-ray of the chest. OBJECTIVE: To verify the presence of ischemic and heart rate changes and the impact of the anesthetic procedure on these patients. Also to verify, in this population, the value of continuous ambulatory monitoring as a preoperative evaluation, a procedure that is not recommended by current guidelines. METHODS: In this protocol, we used continuous ambulatory monitoring (Holter System), in the perioperative period of 30 patients, aged over 65 years, who underwent transurethral resection of the prostate under spinal anesthesia. RESULTS: In the preoperative and transoperative evaluations, frequent complex ventricular and supraventricular arrhythmias were observed, and also ischemic changes. In the transoperative recording, the patients who had ischemic episodes were the same ones who showed total ischemic burden of more than 60 minutes in the preoperative recording. CONCLUSION: Ambulatory monitoring is not regarded as an appropriate procedure for the screening of myocardial ischemia, due to the characteristics and technical limitations of the method, especially in populations with a low prevalence of coronary disease. In this cross-sectional and observational study, we concluded that the Holter recordings provided additional information which could not be obtained by conventional electrocardiogram.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Electrocardiografía Ambulatoria/normas , Isquemia Miocárdica/diagnóstico , Atención Perioperativa/normas , Prostatectomía , Anciano , Anciano de 80 o más Años , Anestesia Raquidea/efectos adversos , Estudios Transversales , Humanos , Masculino , Estadísticas no Paramétricas
15.
Arq Bras Cardiol ; 93(3): 299-306, 2009 Sep.
Artículo en Inglés, Portugués, Español | MEDLINE | ID: mdl-19851659

RESUMEN

BACKGROUND: Percutaneous aortic valve replacement for the treatment of aortic stenosis is an available and efficient alternative for patients at high surgical risk, especially those with advanced age and comorbidities. OBJECTIVE: The authors report the first experience made in our midst with the use of the CoreValve endoprosthesis. METHODS: In January 2008, two patients underwent percutaneous aortic valve replacement due to symptomatic aortic stenosis. They were selected for being elderly (77 and 87 years) and presenting comorbidities and a high surgical risk (EuroScore 7.7% and 12.1%). RESULTS: Percutaneous implantations of the CoreValve device were successfully performed. Enlargement of the valve area (from 0.7 to 1.5 cm(2) and from 0.5 to 1.3 cm(2)) and reduction of the aortic transvalvular gradient (from 82 to 50 mmHg and from 94 to 31 mmHg) were observed immediately after the intervention. During hospital stay, permanent pacemaker implantation was required in both patients due to atrioventricular block. At six months, an even greater drop in the aortic transvalvular gradient (gradient < 20 mmHg) and remission of symptoms of heart failure (NYHA III to NYHA I) were observed. CONCLUSION: The use of the CoreValve endoprosthesis for the treatment of aortic stenosis proved to be feasible and showed encouraging results in this early experience made in our midst.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/patología , Bioprótesis , Cateterismo Cardíaco/métodos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Masculino , Stents
16.
Arq. bras. cardiol ; 100(2): 180-186, fev. 2013. tab
Artículo en Portugués | LILACS | ID: lil-667960

RESUMEN

FUNDAMENTO: Diversos mecanismos podem estar envolvidos no desencadeamento da síncope em pacientes com cardiomiopatia hipertrófica (CMH), incluindo colapsos hemodinâmicos que podem estar relacionados a um desequilíbrio autonômico. OBJETIVO: Avaliar e comparar a função autonômica de pacientes que apresentam CMH com síncope inexplicada (SI) com os que não apresentam síncope. MÉTODOS: Trinta e sete pacientes foram incluídos, sendo 16 com SI e 21 sem síncope. Sua função autonômica foi avaliada por sensibilidade barorreflexa (SB) espontânea e induzida por fenilefrina, pela variabilidade da frequência cardíaca (VFC) no domínio do tempo durante o Holter de 24 horas e no domínio da frequência (análise espectral), ambos em decúbito dorsal e no teste de inclinação (TI) a 70º. RESULTADOS: A SB espontânea mostrou-se semelhante em ambos os grupos (16,46 ± 12,99 vs. 18,31 ± 9,88 ms/mmHg, p = 0,464), assim como a SB induzida por fenilefrina (18,33 ± 9,31 vs. 15,83 ± 15,48 ms/mmHg, p = 0,521). Não foram observadas diferenças no SDNN (137,69 ± 36,62 vs . 145,95 ± 38,07 ms, p = 0,389). O grupo com síncope apresentou um RMSSD significativamente menor (24,88 ± 10,03 vs. 35,58 ± 16,43 ms, p = 0,042) e tendência a menor pNN50 (4,51 ± 3,78 vs . 8,83 ± 7,98%, p =0,085) e a menores valores do componente de alta frequência da análise espectral da VFC em repouso (637,59 ± 1.295,53 vs. 782,65 ± 1.264,14 ms2 , p = 0,075). Nenhuma diferença significativa foi observada em resposta ao TI (p = 0,053). A sensibilidade, especificidade e acurácia do TI na identificação da etiologia da SI em pacientes com CMH foram 6%, 66% e 40%, respectivamente. CONCLUSÃO: Observou-se tônus parassimpático mais baixo em pacientes com CMH e SI, mas a relevância clínica deste achado ainda não está clara. O TI não é uma ferramenta vantajosa para avaliar a origem da síncope em tais doentes, principalmente por causa da sua baixa especificidade.


BACKGROUND: Several mechanisms may be involved in the trigger of syncope in patients with hypertrophic cardiomyopathy (HCM), including hemodynamic collapses that might be related to an autonomic imbalance. OBJECTIVE: To evaluate and compare the autonomic function of patients presenting HCM with unexplained syncope (US) to those without syncope. METHODS: Thirty-seven patients were included, 16 with US and 21 without syncope. Their autonomic function was assessed by spontaneous and phenylephrine induced baroreflex sensitivity (BRS), by heart rate variability (HRV) in time domain during 24-hour Holter and in frequency domain (spectral analysis), both in supine position and at 70º head-up tilt (HUT). RESULTS: The spontaneous BRS was similar in both groups (16,46 ± 12,99 vs. 18,31 ± 9,88 ms/mmHg, p = 0,464), as was phenylephrine-induced BRS (18,33 ± 9,31 vs. 15,83 ± 15,48 ms/mmHg, p = 0,521). No differences were observed in SDNN (137,69 ± 36,62 vs . 145,95 ± 38,07 ms, p=0,389). The group presenting syncope had a significantly lower RMSSD (24,88±10,03 vs. 35,58 ± 16,43 ms, p = 0,042) and a tendency to lower pNN50 (4,51 ± 3,78 vs . 8,83 ± 7,98%, p =0,085) and lower values of the high frequency component of HRV spectral analysis at rest (637,59±1.295,53 vs. 782,65±1.264,14ms2, p=0,075). No significant difference was observed in response to HUT (p = 0,053). HUT sensitivity, specificity and accuracy in identifying the etiology of US in HCM patients were 6%, 66% and 40%, respectively. CONCLUSIONS: A lower parasympathetic tone was observed in HCM patients with US, but the clinical relevance of this finding remains unclear. HUT is not a valuable tool for evaluating the origin of syncope in these patients, mainly because of its poor specificity.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Sistema Nervioso Autónomo/fisiopatología , Barorreflejo/fisiología , Cardiomiopatía Hipertrófica/fisiopatología , Frecuencia Cardíaca/fisiología , Síncope/fisiopatología , Barorreflejo/efectos de los fármacos , Métodos Epidemiológicos , Fenilefrina/administración & dosificación , Posición Supina/fisiología , Pruebas de Mesa Inclinada
17.
Arq Bras Cardiol ; 91(3): 128-33, 142-7, 2008 Sep.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-18853053

RESUMEN

BACKGROUND: The routine use of local anesthetics associated to vasoconstrictors for the dental treatment of patients with cardiopathies is still controversial, due to the risk of adverse cardiovascular effects. OBJECTIVE: To evaluate and compare the hemodynamic effects of the use of local anesthetics with a non-adrenergic vasoconstrictor in patients with ventricular arrhythmia, when compared to the use of anesthetics without vasoconstrictor. METHODS: A prospective randomized study evaluated 33 patients with positive serology for Chagas' disease and 32 patients with coronary artery disease that presented complex ventricular arrhythmia at Holter monitoring (>10 EV/h and NSVT), of which 21 were females, aged 54.73 + 7.94 years, submitted to routine dental treatment with pterygomandibular anesthesia. These patients were divided in two groups: group I received prilocaine 3% associated with felypressin 0.03 IU/ml and group II received lidocaine 2% without vasoconstrictor. The number and complexity of extrasystoles were analyzed, as well as the heart rate and systemic arterial pressure of the patients on the day before, one hour before, during the procedure and one hour after the dental procedure. RESULTS: No hemodynamic alterations or increase in the number and complexity of the ventricular arrhythmia related to the anesthetic used in the dental procedure were observed in either group. CONCLUSION: The results suggest that prilocaine 3% associated to a felypressin 0.03 IU/ml can be safely used in patients with Chagas' disease or coronariopathy with complex ventricular arrhythmia.


Asunto(s)
Anestesia Dental/efectos adversos , Anestésicos Locales/efectos adversos , Arritmias Cardíacas/fisiopatología , Cardiomiopatía Chagásica/fisiopatología , Vasoconstrictores/efectos adversos , Adolescente , Adulto , Anciano , Presión Sanguínea/efectos de los fármacos , Electrocardiografía Ambulatoria , Felipresina/efectos adversos , Femenino , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Lidocaína/efectos adversos , Masculino , Persona de Mediana Edad , Prilocaína/efectos adversos , Estudios Prospectivos , Factores de Tiempo , Adulto Joven
18.
Arq. bras. cardiol ; 101(2): 101-105, ago. 2013. tab
Artículo en Portugués | LILACS | ID: lil-685394

RESUMEN

FUNDAMENTOS: Inúmeros indicadores são utilizados para assegurar a qualidade de um serviço; entretanto, a competência médica e o adequado fluxo de realização de um procedimento são determinantes da qualidade final. Nesse contexto, a Sociedade Brasileira de Arritmias Cardíacas pretende recomendar parâmetros mínimos necessários para garantir a excelência dos serviços de monitorização eletrocardiográfica ambulatorial. OBJETIVOS: Recomendar competências médicas mínimas e as informações necessárias para emissão do laudo de Holter. MÉTODOS: O documento foi fundamentado no conceito de medicina baseada em evidência, e nas circunstâncias em que a evidência não estava disponível a opinião de uma comissão de redação foi utilizada para a formulação da recomendação. Essa comissão foi formada por profissionais que apresentam vivência nas dificuldades do método e gestão na prestação de serviços nessa área. RESULTADOS: O profissional responsável pela análise de Holter deve conhecer as patologias cardiovasculares e ter formação consistente em eletrocardiografia, incluindo arritmias cardíacas e seus diagnósticos diferenciais. O laudo deve ser redigido de forma clara e objetiva. Os parâmetros mínimos que devem constar no laudo incluem as estatísticas do exame, assim como quantificação e análise dos distúrbios do ritmo observados durante a monitorização. CONCLUSÃO: A monitorização eletrocardiográfica ambulatorial deve ser realizada por profissionais com vivência em análise eletrocardiográfica e o laudo deve conter os parâmetros mínimos mencionados nesse documento.


BACKGROUND: There are innumerous indicators to assure the quality of a service. However, medical competence and the proper performance of a procedure determine its final quality. The Brazilian Society of Cardiac Arrhythmias recommends minimum parameters necessary to guarantee the excellence of ambulatory electrocardiographic monitoring services. OBJECTIVE: To recommend minimum medical competences and the information required to issue a Holter monitoring report. METHODS: This study was grounded in the concept of evidence-based medicine and, when evidence was not available, the opinion of a writing committee was used to formulate the recommendation. That committee consisted of professionals with experience on the difficulties of the method and management in providing services in that area. RESULTS: The professional responsible for the Holter monitoring analysis should know cardiovascular pathologies and have consistent formation on electrocardiography, including cardiac arrhythmias and their differential diagnoses. The report should be written in a clear and objective way. The minimum parameters that comprise a Holter report should include statistics of the exam, as well as quantification and analysis of the rhythm disorders observed during monitoring. CONCLUSION: Ambulatory electrocardiographic monitoring should be performed by professionals knowledgeable about electrocardiographic analysis, whose report should comprise the minimum parameters mentioned in this document.


Asunto(s)
Humanos , Arritmias Cardíacas/diagnóstico , Medicina Basada en la Evidencia , Electrocardiografía Ambulatoria/normas , Brasil , Cardiología/normas , Sociedades Médicas/normas
19.
Rev. bras. cardiol. invasiva ; 18(2): 128-134, jun. 2010. ilus, tab
Artículo en Portugués | LILACS | ID: lil-559917

RESUMEN

Introdução: O sistema de condução localizado no septo interventricular encontra-se anatomicamente contíguo ao anel valvar aórtico. Por isso, distúrbios na condução atrioventricular e intraventricular podem decorrer de inflamação, edema e estresse mecânico causados pelas hastes metálicas da bioprótese CoreValve. O objetivo deste estudo foi avaliar a incidência de distúrbios da condução atrioventricular e intraventricular após implante percutâneo da CoreValve. Método: Entre janeiro de 2008 e abril de 2010, 23 pacientes portadores de estenose aórtica foram submetidos a implante da CoreValve. A média de idade foi de 81 ± 8,3 anos, e 12 (52,1%) pacientes eram do sexo masculino. Resultados: Após o implante valvar, constataram-se as seguintes alterações na condução atrioventricular: 3 (13%) bloqueios atrioventriculares totais, 2 (8,7%) bloqueios atrioventriculares de 2º grau e 8 (34,8%) bloqueios atrioventriculares de 1º grau, sendo 4 (17,4%) novos e 4 preexistentes. Assim, distúrbios de condução mais avançados, como bloqueio atrioventricular de 2o grau e/ou bloqueio atrioventricular total ocorreram em 5 (21,7%) pacientes. Em relação aos distúrbios da condução intraventricular pós-implante, foram detectados 14 (60,9%) bloqueios completos de ramo esquerdo, sendo 2 (8,7%) com bloqueio completo de ramo direito e bloqueio completo de ramo esquerdo alternante. Nesta série, 7 (30,4%) pacientes foram submetidos a implante de marca-passo permanente, 6 (26,1%) deles por indicação absoluta. Todos os pacientes que apresentavam bloqueio completo de ramo direito antes do procedimento necessitaram do marca-passo permanente...


Background: There is a close anatomical relationship between the aortic valve annulus and the conduction system.Therefore, atrioventricular and intraventricular conduction disorders may occur as a result of inflammation, edema and mechanical stress caused by the metallic struts of the CoreValvebioprosthesis. The objective of this study was to evaluate the incidence of atrioventricular and intraventricular conduction disorders after percutaneous CoreValve implantation.Method: Between January 2008 and April 2010, 23 patients with aortic stenosis were submitted to CoreValve bioprosthesis implantation. Mean age was 81 ± 8.3 years and 12 (52.1%) patients were male. Results: After valve implantation, the following atrioventricular conduction disorderswere observed: 3 (13%) complete atrioventricular blocks, 2 (8.7%) 2nd degree atrioventricular blocks and 8 (34.8%) 1st degree atrioventricular blocks, of which 4 (17.4%) werenew and 4 were preexisting. Therefore, advanced conduction disorders, such as 2nd degree atrioventricular block and/orcomplete atrioventricular block were observed in 5 (21.7%) patients. As to post-implant intraventricular conductiondisorders, 14 (60.9%) left bundle branch blocks were observed, 2 (8.7%) of them with alternating right bundle branch block and left bundle branch block. In this series, 7 (30.4%) patients received a permanent pacemaker, 6 (26.1%) of them with absolute indication. All of the patients withright bundle branch block before the procedure required permanent pacemaker implantation. Conclusion: Atrioventricular conduction disorders and, specially, left bundle branch block are common after percutaneous implantation of the CoreValve prosthesis. Permanent pacemaker is required in approximately one fourth of the cases. The presence of pre-implant right bundle branch block is related to a greater risk of developing advanced conduction disorders.


Asunto(s)
Humanos , Estenosis de la Válvula Aórtica/sangre , Marcapaso Artificial , Prótesis Valvulares Cardíacas/ética , Bloqueo Cardíaco , Electrocardiografía/métodos
20.
Arq. bras. cardiol ; 93(4): 409-417, out. 2009. graf, tab
Artículo en Inglés, Portugués | LILACS | ID: lil-531211

RESUMEN

FUNDAMENTO: Em pacientes do sexo masculino, com idade acima de 65 anos e sem história de cardiopatia, faz-se necessário, assim como exames de avaliação pré-operatória, hemograma, eletrocardiograma e raios X do tórax. OBJETIVO: Tivemos como objetivo verificar se, nesses pacientes, estariam presentes alterações isquêmicas e no ritmo cardíaco, bem como o impacto do procedimento anestésico. Visamos, também, a verificar a validade da monitorização ambulatorial contínua como exame de avaliação pré-operatória nessa população, o qual não foi recomendado pelas atuais diretrizes. MÉTODOS: Utilizamos, neste protocolo, a monitorização ambulatorial contínua (Sistema Holter) no período perioperatório de 30 pacientes com idade superior a 65 anos, os quais foram submetidos à ressecção transuretral de próstata sob raquianestesia. RESULTADOS: Encontramos nas avaliações pré-operatória e transoperatória frequentes arritmias ventriculares e supraventriculares complexas, bem como alterações isquêmicas. Na gravação transoperatória, os pacientes que apresentaram episódios isquêmicos foram os mesmos que, na gravação pré-operatória, mostraram carga isquêmica total maior do que 60 minutos. CONCLUSÃO: Aceitamos que a monitorização ambulatorial não seja um procedimento adequado para o screening da isquemia miocárdica, pelas próprias características e limitações técnicas que envolvem o método, principalmente quando são considerados grupos populacionais com baixa prevalência da doença coronariana. Concluímos que, neste estudo transverso e observacional, obtivemos informações complementares com o holter, as quais não puderam ser obtidas pelo eletrocardiograma convencional.


BACKGROUND: Male patients, aged over 65 years and with no history of heart disease, need the following tests as a preoperative evaluation: blood count, electrocardiogram and X-ray of the chest. OBJECTIVE: To verify the presence of ischemic and heart rate changes and the impact of the anesthetic procedure on these patients. Also to verify, in this population, the value of continuous ambulatory monitoring as a preoperative evaluation, a procedure that is not recommended by current guidelines. METHODS: In this protocol, we used continuous ambulatory monitoring (Holter System), in the perioperative period of 30 patients, aged over 65 years, who underwent transurethral resection of the prostate under spinal anesthesia. RESULTS: In the preoperative and transoperative evaluations, frequent complex ventricular and supraventricular arrhythmias were observed, and also ischemic changes. In the transoperative recording, the patients who had ischemic episodes were the same ones who showed total ischemic burden of more than 60 minutes in the preoperative recording. CONCLUSION: Ambulatory monitoring is not regarded as an appropriate procedure for the screening of myocardial ischemia, due to the characteristics and technical limitations of the method, especially in populations with a low prevalence of coronary disease. In this cross-sectional and observational study, we concluded that the Holter recordings provided additional information which could not be obtained by conventional electrocardiogram.


Asunto(s)
Anciano , Anciano de 80 o más Años , Humanos , Masculino , Arritmias Cardíacas/diagnóstico , Electrocardiografía Ambulatoria/normas , Isquemia Miocárdica/diagnóstico , Prostatectomía , Atención Perioperativa/normas , Anestesia Raquidea/efectos adversos , Estudios Transversales , Estadísticas no Paramétricas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA