1.
Circulation ; 2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-39051104

RESUMEN

BACKGROUND: Whether vigorous exercise increases risk of ventricular arrhythmias for individuals diagnosed and treated for congenital long-QT syndrome (LQTS) remains unknown. METHODS: The National Institutes of Health-funded LIVE-LQTS study (Lifestyle and Exercise in Genetic Cardiovascular Conditions) prospectively enrolled individuals 8 to 60 years of age with phenotypic or genotypic LQTS from 37 sites in 5 countries from May 2015 to February 2019. Participants (or parents) answered physical activity and clinical events surveys every 6 months for 3 years with follow-up completed in February 2022. Vigorous exercise was defined as ≥6 metabolic equivalents for >60 hours per year. A blinded Clinical Events Committee adjudicated the composite end point of sudden death, sudden cardiac arrest, ventricular arrhythmia treated by an implantable cardioverter defibrillator, and likely arrhythmic syncope. A National Death Index search ascertained vital status for those with incomplete follow-up. A noninferiority hypothesis (boundary of 1.5) between vigorous exercisers and others was tested with multivariable Cox regression analysis. RESULTS: Among the 1413 participants (13% <18 years of age, 35% 18-25 years of age, 67% female, 25% with implantable cardioverter defibrillators, 90% genotype positive, and 49% with LQT1), 91% were treated with beta-blockers, left cardiac sympathetic denervation, or implantable cardioverter defibrillator; 52% participated in vigorous exercise (55% competitively). Thirty-seven individuals experienced the composite end point (including one sudden cardiac arrest and one sudden death in the nonvigorous group, one sudden cardiac arrest in the vigorous group) with overall event rates at 3 years of 2.6% in the vigorous and 2.7% in the nonvigorous exercise groups. The unadjusted hazard ratio for experience of events for the vigorous group compared with the nonvigorous group was 0.97 (90% CI, 0.57-1.67), with an adjusted hazard ratio of 1.17 (90% CI, 0.67-2.04). The upper 95% one-sided confidence level extended beyond the 1.5 boundary. Neither vigorous or nonvigorous exercise was found to be superior in any group or subgroup. CONCLUSIONS: Among individuals diagnosed with phenotypic or genotypic LQTS who were risk assessed and treated in experienced centers, LQTS-associated cardiac event rates were low and similar between those exercising vigorously and those not exercising vigorously. Consistent with the low event rate, CIs are wide, and noninferiority was not demonstrated. These data further inform shared decision-making discussions between patient and physician about exercise and competitive sports participation. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02549664.

2.
Eur Heart J ; 42(17): 1676-1684, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33417692

RESUMEN

AIMS: The benefit of prophylactic implantable cardioverter-defibrillator (ICD) is not uniform due to differences in the risk of life-threatening ventricular tachycardia (VT)/ventricular fibrillation (VF) and non-arrhythmic mortality. We aimed to develop an ICD benefit prediction score that integrates the competing risks. METHODS AND RESULTS: The study population comprised all 4531 patients enrolled in the MADIT trials. Best-subsets Fine and Gray regression analysis was used to develop prognostic models for VT (≥200 b.p.m.)/VF vs. non-arrhythmic mortality (defined as death without prior sustained VT/VF). Eight predictors of VT/VF (male, age < 75 years, prior non-sustained VT, heart rate > 75 b.p.m., systolic blood pressure < 140 mmHg, ejection fraction ≤ 25%, myocardial infarction, and atrialarrhythmia) and 7 predictors of non-arrhythmic mortality (age ≥ 75 years, diabetes mellitus, body mass index < 23 kg/m2, ejection fraction ≤ 25%, New York Heart Association ≥II, ICD vs. cardiac resynchronization therapy with defibrillator, and atrial arrhythmia) were identified. The two scores were combined to create three MADIT-ICD benefit groups. In the highest benefit group, the 3-year predicted risk of VT/VF was three-fold higher than the risk of non-arrhythmic mortality (20% vs. 7%, P < 0.001). In the intermediate benefit group, the difference in the corresponding predicted risks was attenuated (15% vs. 9%, P < 0.01). In the lowest benefit group, the 3-year predicted risk of VT/VF was similar to the risk of non-arrhythmic mortality (11% vs. 12%, P = 0.41). A personalized ICD benefit score was developed based on the distribution of the two competing risks scores in the study population (https://is.gd/madit). Internal and external validation confirmed model stability. CONCLUSIONS: We propose the novel MADIT-ICD benefit score that predicts the likelihood of prophylactic ICD benefit through personalized assessment of the risk of VT/VF weighed against the risk of non-arrhythmic mortality.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Taquicardia Ventricular , Anciano , Arritmias Cardíacas/terapia , Humanos , Masculino , Factores de Riesgo , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia
3.
N Engl J Med ; 370(18): 1694-701, 2014 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-24678999

RESUMEN

BACKGROUND: The Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy (MADIT-CRT) showed that early intervention with cardiac-resynchronization therapy with a defibrillator (CRT-D) in patients with an electrocardiographic pattern showing left bundle-branch block was associated with a significant reduction in heart-failure events over a median follow-up of 2.4 years, as compared with defibrillator therapy alone. METHODS: We evaluated the effect of CRT-D on long-term survival in the MADIT-CRT population. Post-trial follow-up over a median period of 5.6 years was assessed among all 1691 surviving patients (phase 1) and subsequently among 854 patients who were enrolled in post-trial registries (phase 2). All reported analyses were performed on an intention-to-treat basis. RESULTS: At 7 years of follow-up after initial enrollment, the cumulative rate of death from any cause among patients with left bundle-branch block was 18% among patients randomly assigned to CRT-D, as compared with 29% among those randomly assigned to defibrillator therapy alone (adjusted hazard ratio in the CRT-D group, 0.59; 95% confidence interval [CI], 0.43 to 0.80; P<0.001). The long-term survival benefit of CRT-D in patients with left bundle-branch block did not differ significantly according to sex, cause of cardiomyopathy, or QRS duration. In contrast, CRT-D was not associated with any clinical benefit and possibly with harm in patients without left bundle-branch block (adjusted hazard ratio for death from any cause, 1.57; 95% CI, 1.03 to 2.39; P=0.04; P<0.001 for interaction of treatment with QRS morphologic findings). CONCLUSIONS: Our findings indicate that in patients with mild heart-failure symptoms, left ventricular dysfunction, and left bundle-branch block, early intervention with CRT-D was associated with a significant long-term survival benefit. (Funded by Boston Scientific; ClinicalTrials.gov numbers, NCT00180271, NCT01294449, and NCT02060110.).


Asunto(s)
Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/terapia , Anciano , Bloqueo de Rama/complicaciones , Terapia Combinada , Desfibriladores Implantables , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/prevención & control , Humanos , Análisis de Intención de Tratar , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Índice de Severidad de la Enfermedad , Volumen Sistólico , Disfunción Ventricular Izquierda/complicaciones
4.
Am Heart J ; 189: 158-166, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28625372

RESUMEN

Patients with diabetes mellitus, prior myocardial infarction, older age, and a relatively preserved left ventricular ejection fraction remain at risk for sudden cardiac death that is potentially amenable by the subcutaneous implantable cardioverter defibrillator with a good risk-benefit profile. The launched MADIT S-ICD study is designed to test the hypothesis that post-myocardial infarction diabetes patients with relatively preserved ejection fraction of 36%-50% will have a survival benefit from a subcutaneous implantable cardioverter defibrillator.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Infarto del Miocardio/complicaciones , Anciano , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Estudios Prospectivos , Tasa de Supervivencia/tendencias , Resultado del Tratamiento , Estados Unidos/epidemiología
5.
Artículo en Inglés | MEDLINE | ID: mdl-27629147

RESUMEN

BACKGROUND: The effect of chronic kidney disease (CKD) on benefit from cardiac resynchronization therapy with defibrillator (CRT-D) in reducing ventricular tachyarrhythmia (VTA) risk among mild heart failure (HF) patients is not well understood. METHODS: We evaluated the impact of baseline renal function on VTAs in 1274 left bundle branch block (LBBB) patients enrolled in MADIT-CRT. Two prespecified subgroups were created based on estimated glomerular filtration rate (GFR): GFR <60 (n = 413) and GFR ≥60 ml/min/1.73 m2 (n = 861). Primary end point was ventricular tachycardia/ventricular fibrillation/death (VT/VF/death). Secondary end points were any VT/VF and ventricular tachycardia ≥ 200 bpm or VF (fast VT/VF). RESULTS: There were 413 (32%) LBBB patients presenting with CKD, primarily of moderate severity (GFR mean 48.1 ± 8.3). For patients with and without CKD, CRT-D was associated with lower risk of the primary end point (GFR<60: HR = 0.61, 95% CI: 0.41-0.89, p = .010; GFR≥60: HR = 0.58, 95% CI: 0.52-0.89, p = .005), relative to ICD-only treatment. For patients in both renal function categories, CRT-D in comparison to ICD alone was associated with lower risk of VT/VF (GFR<60: HR = 0.68, 95% CI: 0.42-1.10, p = .113; GFR≥60: HR = 0.65, 95% CI: 0.48-0.88, p = .005) and fast VT/VF (GFR<60: HR = 0.49, 95% CI: 0.25-0.96, p = .038; GFR≥60: HR = 0.55, 95% CI: 0.39-0.80, p = .001), when accounting for competing mortality risk. This effect was independent of CRT-induced reverse remodeling. CONCLUSION: Among mild HF patients with LBBB, those with and without CKD both derived benefit from CRT-D in risk reduction in VTAs, independent of cardiac reverse remodeling.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/métodos , Insuficiencia Renal Crónica/complicaciones , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/diagnóstico , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Taquicardia Ventricular/prevención & control , Resultado del Tratamiento
6.
N Engl J Med ; 367(24): 2275-83, 2012 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-23131066

RESUMEN

BACKGROUND: The implantable cardioverter-defibrillator (ICD) is highly effective in reducing mortality among patients at risk for fatal arrhythmias, but inappropriate ICD activations are frequent, with potential adverse effects. METHODS: We randomly assigned 1500 patients with a primary-prevention indication to receive an ICD with one of three programming configurations. The primary objective was to determine whether programmed high-rate therapy (with a 2.5-second delay before the initiation of therapy at a heart rate of ≥200 beats per minute) or delayed therapy (with a 60-second delay at 170 to 199 beats per minute, a 12-second delay at 200 to 249 beats per minute, and a 2.5-second delay at ≥250 beats per minute) was associated with a decrease in the number of patients with a first occurrence of inappropriate antitachycardia pacing or shocks, as compared with conventional programming (with a 2.5-second delay at 170 to 199 beats per minute and a 1.0-second delay at ≥200 beats per minute). RESULTS: During an average follow-up of 1.4 years, high-rate therapy and delayed ICD therapy, as compared with conventional device programming, were associated with reductions in a first occurrence of inappropriate therapy (hazard ratio with high-rate therapy vs. conventional therapy, 0.21; 95% confidence interval [CI], 0.13 to 0.34; P<0.001; hazard ratio with delayed therapy vs. conventional therapy, 0.24; 95% CI, 0.15 to 0.40; P<0.001) and reductions in all-cause mortality (hazard ratio with high-rate therapy vs. conventional therapy, 0.45; 95% CI, 0.24 to 0.85; P=0.01; hazard ratio with delayed therapy vs. conventional therapy, 0.56; 95% CI, 0.30 to 1.02; P=0.06). There were no significant differences in procedure-related adverse events among the three treatment groups. CONCLUSIONS: Programming of ICD therapies for tachyarrhythmias of 200 beats per minute or higher or with a prolonged delay in therapy at 170 beats per minute or higher, as compared with conventional programming, was associated with reductions in inappropriate therapy and all-cause mortality during long-term follow-up. (Funded by Boston Scientific; MADIT-RIT ClinicalTrials.gov number, NCT00947310.).


Asunto(s)
Desfibriladores Implantables , Taquicardia/terapia , Anciano , Desfibriladores Implantables/efectos adversos , Diseño de Equipo , Falla de Equipo , Femenino , Estudios de Seguimiento , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Taquicardia/diagnóstico , Taquicardia/mortalidad , Factores de Tiempo
7.
Circulation ; 127(20): 2021-30, 2013 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-23690453

RESUMEN

BACKGROUND: The risks of sports participation for implantable cardioverter-defibrillator (ICD) patients are unknown. METHODS AND RESULTS: Athletes with ICDs (age, 10-60 years) participating in organized (n=328) or high-risk (n=44) sports were recruited. Sports-related and clinical data were obtained by phone interview and medical records. Follow-up occurred every 6 months. ICD shock data and clinical outcomes were adjudicated by 2 electrophysiologists. Median age was 33 years (89 subjects <20 years of age); 33% were female. Sixty were competitive athletes (varsity/junior varsity/traveling team). A pre-ICD history of ventricular arrhythmia was present in 42%. Running, basketball, and soccer were the most common sports. Over a median 31-month (interquartile range, 21-46 months) follow-up, there were no occurrences of either primary end point-death or resuscitated arrest or arrhythmia- or shock-related injury-during sports. There were 49 shocks in 37 participants (10% of study population) during competition/practice, 39 shocks in 29 participants (8%) during other physical activity, and 33 shocks in 24 participants (6%) at rest. In 8 ventricular arrhythmia episodes (device defined), multiple shocks were received: 1 at rest, 4 during competition/practice, and 3 during other physical activity. Ultimately, the ICD terminated all episodes. Freedom from lead malfunction was 97% at 5 years (from implantation) and 90% at 10 years. CONCLUSIONS: Many athletes with ICDs can engage in vigorous and competitive sports without physical injury or failure to terminate the arrhythmia despite the occurrence of both inappropriate and appropriate shocks. These data provide a basis for more informed physician and patient decision making in terms of sports participation for athletes with ICDs.


Asunto(s)
Atletas , Traumatismos en Atletas/epidemiología , Desfibriladores Implantables/normas , Sistema de Registros , Deportes/normas , Adolescente , Adulto , Traumatismos en Atletas/prevención & control , Niño , Desfibriladores Implantables/efectos adversos , Femenino , Humanos , Internacionalidad , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Adulto Joven
8.
Europace ; 16(7): 1007-14, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24446509

RESUMEN

AIMS: The step-wise approach to catheter ablation for persistent atrial fibrillation (AF) requires considerable substrate modification targeting at complex fractionated atrial electrograms (CFAEs) in addition to pulmonary vein (PV) isolation. An alternative strategy that minimizes the amount of ablation would be desirable. The aim of this study was to investigate whether the use of pre-procedural amiodarone affects: (i) the amount of ablation required to achieve procedural success, and (ii) long-term outcomes. METHODS AND RESULTS: We studied 121 consecutive patients with persistent AF who underwent catheter ablation. The patients were divided into two groups: Group 1, amiodarone (n = 31); Group 2, other antiarrhythmic drugs or rate control (n = 90). All the patients underwent a step-wise ablation procedure beginning with PV isolation, then proceeding with ablation of the CFAEs and linear lesions until sinus rhythm was achieved. Mean left atrial cycle length of AF (AFCL) was recorded at each step. The number of CFAE ablation sites was recorded. The number of CFAE sites in Group 1 was significantly less than that in Group 2 (P = 0.0121). The AFCLs after each step in Group 1 were significantly longer than those in Group 2. The procedure time and the radiofrequency time of CFAE ablation in Group 1 were significantly shorter than that in Group 2 (P = 0.0276 and P = 0.0458, respectively). There was no significant difference between the two groups in early and long-term outcomes. CONCLUSION: Use of pre-procedural amiodarone prolongs AFCL during catheter ablation and reduces the number of CFAE sites requiring ablation to achieve procedural success while maintaining equivalent long-term results.


Asunto(s)
Amiodarona/uso terapéutico , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/terapia , Ablación por Catéter , Tempo Operativo , Venas Pulmonares/efectos de los fármacos , Anciano , Amiodarona/efectos adversos , Antiarrítmicos/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Terapia Combinada , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
11.
J Cardiovasc Electrophysiol ; 24(4): 442-8, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23252875

RESUMEN

BACKGROUND: Mildly symptomatic heart failure (HF) patients derive substantial clinical benefit from cardiac resynchronization therapy with defibrillator (CRT-D) as shown in MADIT-CRT. The presence of QRS axis deviation may influence response to CRT-D. The objective of this study was to determine whether QRS axis deviation will be associated with differential benefit from CRT-D. METHODS: Baseline electrocardiograms of 1,820 patients from MADIT-CRT were evaluated for left axis deviation (LAD: quantitative QRS axis -30 to -90) or right axis deviation (RAD: QRS axis 90-180) in left bundle branch block (LBBB), right bundle branch block (RBBB), and nonspecific interventricular conduction delay QRS morphologies. The primary endpoints were the first occurrence of a HF event or death and the separate occurrence of all-cause mortality as in MADIT-CRT. RESULTS: Among LBBB patients, those with LAD had a higher risk of primary events at 2 years than non-LAD patients (20% vs 16%; P = 0.024). The same was observed among RBBB patients (20% vs 10%; P = 0.05) but not in IVCD patients (22% vs 23%; P = NS). RAD did not convey any increased risk of the primary combined endpoint in any QRS morphology subgroup. When analyzing the benefit of CRT-D in the non-LBBB subgroups, there was no significant difference in hazard ratios for CRT-D versus ICD for either LAD or RAD. However, LBBB patients without LAD showed a trend toward greater benefit from CRT therapy than LBBB patients with LAD (HR for no LAD: 0.37, 95% CI: 0.26-0.53 and with LAD: 0.54, 95% CI: 0.36-0.79; P value for interaction = 0.18). CONCLUSIONS: LAD in non-LBBB patients (RBBB or IVCD) is not associated with an increased benefit from CRT. In LBBB patients, those without LAD seem to benefit more from CRT-D than those with LAD.


Asunto(s)
Bloqueo de Rama/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Sistema de Conducción Cardíaco/fisiopatología , Insuficiencia Cardíaca/terapia , Potenciales de Acción , Anciano , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Bloqueo de Rama/mortalidad , Bloqueo de Rama/fisiopatología , Canadá , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/mortalidad , Distribución de Chi-Cuadrado , Electrocardiografía , Europa (Continente) , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Selección de Paciente , Modelos de Riesgos Proporcionales , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Función Ventricular Izquierda , Remodelación Ventricular
12.
JAMA Cardiol ; 8(6): 595-605, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37195701

RESUMEN

Importance: Whether vigorous intensity exercise is associated with an increase in risk of ventricular arrhythmias in individuals with hypertrophic cardiomyopathy (HCM) is unknown. Objective: To determine whether engagement in vigorous exercise is associated with increased risk for ventricular arrhythmias and/or mortality in individuals with HCM. The a priori hypothesis was that participants engaging in vigorous activity were not more likely to have an arrhythmic event or die than those who reported nonvigorous activity. Design, Setting, and Participants: This was an investigator-initiated, prospective cohort study. Participants were enrolled from May 18, 2015, to April 25, 2019, with completion in February 28, 2022. Participants were categorized according to self-reported levels of physical activity: sedentary, moderate, or vigorous-intensity exercise. This was a multicenter, observational registry with recruitment at 42 high-volume HCM centers in the US and internationally; patients could also self-enroll through the central site. Individuals aged 8 to 60 years diagnosed with HCM or genotype positive without left ventricular hypertrophy (phenotype negative) without conditions precluding exercise were enrolled. Exposures: Amount and intensity of physical activity. Main Outcomes and Measures: The primary prespecified composite end point included death, resuscitated sudden cardiac arrest, arrhythmic syncope, and appropriate shock from an implantable cardioverter defibrillator. All outcome events were adjudicated by an events committee blinded to the patient's exercise category. Results: Among the 1660 total participants (mean [SD] age, 39 [15] years; 996 male [60%]), 252 (15%) were classified as sedentary, and 709 (43%) participated in moderate exercise. Among the 699 individuals (42%) who participated in vigorous-intensity exercise, 259 (37%) participated competitively. A total of 77 individuals (4.6%) reached the composite end point. These individuals included 44 (4.6%) of those classified as nonvigorous and 33 (4.7%) of those classified as vigorous, with corresponding rates of 15.3 and 15.9 per 1000 person-years, respectively. In multivariate Cox regression analysis of the primary composite end point, individuals engaging in vigorous exercise did not experience a higher rate of events compared with the nonvigorous group with an adjusted hazard ratio of 1.01. The upper 95% 1-sided confidence level was 1.48, which was below the prespecified boundary of 1.5 for noninferiority. Conclusions and Relevance: Results of this cohort study suggest that among individuals with HCM or those who are genotype positive/phenotype negative and are treated in experienced centers, those exercising vigorously did not experience a higher rate of death or life-threatening arrhythmias than those exercising moderately or those who were sedentary. These data may inform discussion between the patient and their expert clinician around exercise participation.


Asunto(s)
Cardiomiopatía Hipertrófica , Paro Cardíaco , Masculino , Humanos , Estudios de Cohortes , Estudios Prospectivos , Arritmias Cardíacas/complicaciones , Paro Cardíaco/complicaciones , Ejercicio Físico
13.
Circulation ; 123(11): 1159-66, 2011 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-21382893

RESUMEN

BACKGROUND: An important determinant of successful cardiac resynchronization therapy for heart failure is the position of the left ventricular (LV) pacing lead. The aim of this study was to analyze the impact of the LV lead position on outcome in patients randomized to cardiac resynchronization-defibrillation in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT) study. METHODS AND RESULTS: The location of the LV lead was assessed by means of coronary venograms and chest x-rays recorded at the time of device implantation. The LV lead location was classified along the short axis into an anterior, lateral, or posterior position and along the long axis into a basal, midventricular, or apical region. The primary end point of MADIT-CRT was heart failure (HF) hospitalization or death, whichever came first. The LV lead position was assessed in 799 patients, (55% patients ≥65 years of age, 26% female, 10% LV ejection fraction ≤25%, 55% ischemic cardiomyopathy, and 71% left bundle-branch block) with a follow-up of 29±11 months. The extent of cardiac resynchronization therapy benefit was similar for leads in the anterior, lateral, or posterior position (P=0.652). The apical lead location compared with leads located in the nonapical position (basal or midventricular region) was associated with a significantly increased risk for heart failure/death (hazard ratio=1.72; 95% confidence interval, 1.09 to 2.71; P=0.019) after adjustment for the clinical covariates. The apical lead position was also associated with an increased risk for death (hazard ratio=2.91; 95% confidence interval, 1.42 to 5.97; P=0.004). CONCLUSION: LV leads positioned in the apical region were associated with an unfavorable outcome, suggesting that this lead location should be avoided in cardiac resynchronization therapy. Clinical Trial Registration- URL: http://clinicaltrials.gov. Unique identifier: NCT00180271.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Electrodos Implantados , Insuficiencia Cardíaca/terapia , Adulto , Anciano , Femenino , Ventrículos Cardíacos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Función Ventricular Izquierda
14.
Circulation ; 123(10): 1061-72, 2011 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-21357819

RESUMEN

BACKGROUND: This study aimed to determine whether QRS morphology identifies patients who benefit from cardiac resynchronization therapy with a defibrillator (CRT-D) and whether it influences the risk of primary and secondary end points in patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT) trial. METHODS AND RESULTS: Baseline 12-lead ECGs were evaluated with regard to QRS morphology. Heart failure event or death was the primary end point of the trial. Death, heart failure event, ventricular tachycardia, and ventricular fibrillation were secondary end points. Among 1817 patients with available sinus rhythm ECGs at baseline, there were 1281 (70%) with left bundle-branch block (LBBB), 228 (13%) with right bundle-branch block, and 308 (17%) with nonspecific intraventricular conduction disturbances. The latter 2 groups were defined as non-LBBB groups. Hazard ratios for the primary end point for comparisons of CRT-D patients versus patients who only received an implantable cardioverter defibrillator (ICD) were significantly (P < 0.001) lower in LBBB patients (0.47; P < 0.001) than in non-LBBB patients (1.24; P = 0.257). The risk of ventricular tachycardia, ventricular fibrillation, or death was decreased significantly in CRT-D patients with LBBB but not in non-LBBB patients. Echocardiographic parameters showed significantly (P < 0.001) greater reduction in left ventricular volumes and increase in ejection fraction with CRT-D in LBBB than in non-LBBB patients. CONCLUSIONS: Heart failure patients with New York Heart Association class I or II and ejection fraction ≤ 30% and LBBB derive substantial clinical benefit from CRT-D: a reduction in heart failure progression and a reduction in the risk of ventricular tachyarrhythmias. No clinical benefit was observed in patients with a non-LBBB QRS pattern (right bundle-branch block or intraventricular conduction disturbances). CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00180271.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Anciano , Bloqueo de Rama/diagnóstico por imagen , Bloqueo de Rama/mortalidad , Bloqueo de Rama/terapia , Electrocardiografía , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Riesgo , Volumen Sistólico , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/terapia , Resultado del Tratamiento , Ultrasonografía , Fibrilación Ventricular/diagnóstico por imagen , Fibrilación Ventricular/mortalidad , Fibrilación Ventricular/terapia
15.
N Engl J Med ; 361(14): 1329-38, 2009 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-19723701

RESUMEN

BACKGROUND: This trial was designed to determine whether cardiac-resynchronization therapy (CRT) with biventricular pacing would reduce the risk of death or heart-failure events in patients with mild cardiac symptoms, a reduced ejection fraction, and a wide QRS complex. METHODS: During a 4.5-year period, we enrolled and followed 1820 patients with ischemic or nonischemic cardiomyopathy, an ejection fraction of 30% or less, a QRS duration of 130 msec or more, and New York Heart Association class I or II symptoms. Patients were randomly assigned in a 3:2 ratio to receive CRT plus an implantable cardioverter-defibrillator (ICD) (1089 patients) or an ICD alone (731 patients). The primary end point was death from any cause or a nonfatal heart-failure event (whichever came first). Heart-failure events were diagnosed by physicians who were aware of the treatment assignments, but they were adjudicated by a committee that was unaware of assignments. RESULTS: During an average follow-up of 2.4 years, the primary end point occurred in 187 of 1089 patients in the CRT-ICD group (17.2%) and 185 of 731 patients in the ICD-only group (25.3%) (hazard ratio in the CRT-ICD group, 0.66; 95% confidence interval [CI], 0.52 to 0.84; P=0.001). The benefit did not differ significantly between patients with ischemic cardiomyopathy and those with nonischemic cardiomyopathy. The superiority of CRT was driven by a 41% reduction in the risk of heart-failure events, a finding that was evident primarily in a prespecified subgroup of patients with a QRS duration of 150 msec or more. CRT was associated with a significant reduction in left ventricular volumes and improvement in the ejection fraction. There was no significant difference between the two groups in the overall risk of death, with a 3% annual mortality rate in each treatment group. Serious adverse events were infrequent in the two groups. CONCLUSIONS: CRT combined with ICD decreased the risk of heart-failure events in relatively asymptomatic patients with a low ejection fraction and wide QRS complex. (ClinicalTrials.gov number, NCT00180271.)


Asunto(s)
Estimulación Cardíaca Artificial , Cardioversión Eléctrica , Insuficiencia Cardíaca/terapia , Anciano , Desfibriladores Implantables , Supervivencia sin Enfermedad , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/mortalidad , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Marcapaso Artificial , Volumen Sistólico
16.
Ann Noninvasive Electrocardiol ; 17(3): 176-85, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22816536

RESUMEN

The implantable cardioverter defibrillator (ICD) is highly effective in reducing mortality due to cardiac arrhythmias in high-risk cardiac patients. However, inappropriate therapies caused predominantly by supraventricular tachyarrhythmias (SVTs) remain a significant side effect of ICD therapy despite medical treatment, affecting 8-40% of patients. The MADIT-RIT is a global, prospective, randomized, nonblinded, three-arm, multicenter clinical investigation to be performed in the Unites States, Europe, Canada, Israel and Japan, and will utilize approximately 90 centers with plan to enroll 1500 patients programmed to three treatment arms. The objective of the MADIT-RIT trial is to determine if dual-chamber ICD or CRT-D devices with high rate cutoff (MADIT-RIT-Arm B) and/or long delay in combination with detection enhancements (MADIT-RIT-Arm C) are associated with fewer patients experiencing inappropriate therapies than standard programming (MADIT-RIT-Arm A) during postimplant follow-up of patients with indication for primary prevention device therapy. This paper describes design and analytic plan for the MADIT-RIT trial.


Asunto(s)
Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/estadística & datos numéricos , Errores Médicos/prevención & control , Taquicardia Supraventricular/etiología , Adulto , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Canadá , Desfibriladores Implantables/efectos adversos , Diseño de Equipo , Seguridad de Equipos , Europa (Continente) , Femenino , Humanos , Israel , Japón , Masculino , Persona de Mediana Edad , Selección de Paciente , Pronóstico , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Valores de Referencia , Medición de Riesgo , Análisis de Supervivencia , Taquicardia Supraventricular/mortalidad , Resultado del Tratamiento , Estados Unidos
17.
J Cardiovasc Electrophysiol ; 22(7): 822-4, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21159011

RESUMEN

INTRODUCTION: With the increasing number of patients undergoing repeat catheter ablation procedures for atrial fibrillation, it is not uncommon to encounter a fibrotic interatrial septum that resists the conventional manual advancement of the transseptal sheath. Forceful advancement of the transseptal apparatus can reduce fine control and potentially lead to a higher rate of perforation. CASE: We report a case where adjunctive balloon atrial septostomy was used to facilitate transseptal access in a patient with fibrotic interatrial septum. Using a small-caliber angioplasty balloon and under direct fluoroscopic and transesophageal echocardiogram visualization, balloon septostomy was performed with hand inflation until a "waist" was seen. This technique provides a safe way to control the size of the transseptal access created, and allows the passage of a relatively soft-tipped transseptal sheath across a resistive septum. To our knowledge this is the first published use of balloon atrial septostomy during transseptal puncture for left atrium access in a catheter ablation procedure. CONCLUSION: Balloon atrial septostomy should be considered as an alternative technique for safe transseptal cannulation in select patients in the electrophysiology laboratory or other interventional procedures requiring left atrial access or delivery of large-caliber catheters or sheaths.


Asunto(s)
Angioplastia Coronaria con Balón/estadística & datos numéricos , Fibrilación Atrial/terapia , Tabique Interatrial , Ablación por Catéter , Fibrilación Atrial/fisiopatología , Tabique Interatrial/fisiología , Humanos , Masculino , Persona de Mediana Edad
18.
J Cardiovasc Electrophysiol ; 22(8): 892-7, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21831163

RESUMEN

BACKGROUND: Elderly patients comprise a large portion of patients with heart failure (HF). Limited data exist on the effectiveness of cardiac resynchronization therapy with defibrillator (CRT-D) in patients with mild HF symptoms in this population. METHODS AND RESULTS: The benefit of CRT-D compared with ICD-only therapy in reducing HF or death was assessed by age categories (prespecified as <60 [n = 548], 60-74 [n = 941], and ≥75 [n = 331] years) among 1,820 patients in MADIT-CRT. In patients with ICD-only, there was a graded age-related increase in the Kaplan-Meier cumulative probability of HF or death at 3-year follow-up (19%, 33%, and 36%, in patients aged <60, 60-74, and ≥75 years, respectively, P = 0.003). Multivariate analysis demonstrated that CRT-D therapy was associated with a significant reduction in the risks of HF or death in patients aged 60-74, and ≥75 years (HR = 0.57, P = <0.001 and HR = 0.59, P = 0.017, respectively), and no significant benefit in patients aged <60 years (HR = 0.81, P = 0.3; P-value for all treatment-by-age interactions >0.10). There was no significant difference in the rate of device-related adverse events within 90 days following CRT-D implantation among age-subgroups (16.7%, 15.7%, and 11.7%, in patients <60, 60-74, and ≥75 years, respectively, P = 0.42). CONCLUSION: CRT-D was associated with a significant clinical benefit in older patients (≥60 years) during an average 2.4-year follow-up. These effects were preserved for the elderly patients ≥75 years of age but attenuated in patients <60 years. Elderly patients had no increase in device-related adverse events compared with younger patients.


Asunto(s)
Terapia de Resincronización Cardíaca/tendencias , Cardiomiopatías/prevención & control , Cardiomiopatías/fisiopatología , Prevención Secundaria , Factores de Edad , Anciano , Anciano de 80 o más Años , Cardiomiopatías/terapia , Cardioversión Eléctrica/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
19.
Pacing Clin Electrophysiol ; 34(1): 15-22, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21029137

RESUMEN

BACKGROUND: The relationship between the applied techniques and clinical outcomes after radiofrequency (RF) ablation of atrial fibrillation (AF) remains unclear. We compared the results of ablation by RF delivered via a point-by-point versus catheter dragging technique for the treatment of AF. METHODS: This study included 66 patients with drug-refractory AF who underwent circumferential pulmonary vein (PV) ablation. A point-by-point technique was used in 35 (53%) patients (Group I), and catheter dragging technique in the remaining 31 (47%) patients (Group II). If AF persisted or remained inducible after the PV isolation, additional ablation of complex fractionated atrial electrograms and linear ablation were performed. RESULTS: Significantly, fewer RF applications were delivered in Group II than in Group I. The total RF energy duration delivered was comparable between the two groups (P = 0.55). However, the total energy of RF deliveries was significantly greater in Group II than in Group I (P = 0.02). Despite a longer fluoroscopic exposure time (P = 0.01), the total procedural duration was significantly shorter in Group II than in Group I (P = 0.005). Within 3 months after a single ablation procedure, 24 patients (69%) in Group I versus 13 patients (42%) in Group II had ≥1 recurrence(s) of atrial tachyarrhythmias (P = 0.03). A multivariate analysis showed that a point-by-point ablation was the only independent predictor of early atrial tachyarrhythmia recurrences. CONCLUSIONS: The catheter dragging technique for ablation of AF was associated with a lower early recurrence rate of atrial tachyarrhythmias than the point-by-point technique.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Adulto Joven
20.
J Am Heart Assoc ; 10(17): e021002, 2021 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-34398691

RESUMEN

Background Recently there has been increased interest in a possible association between mast cell activation (MCA) disorder and postural orthostatic tachycardia syndrome (POTS). This study examined the frequency with which symptoms and laboratory findings suggesting MCA disorder occurred in patients diagnosed with POTS. Methods and Results Data were obtained from patients in whom symptoms and orthostatic testing were consistent with a POTS diagnosis. Individuals with <4 months symptom duration, evident ongoing inflammatory disease, suspected volume depletion, or declined consent were excluded. All patients had typical POTS symptoms; some, however, had additional nonorthostatic complaints not usually associated with POTS. The latter patients underwent additional testing for known MCA biochemical mediators including prostaglandins, histamine, methylhistamine, and plasma tryptase. The study comprised 69 patients who met POTS diagnostic criteria. In 44 patients (44/69, 64%) additional nonorthostatic symptoms included migraine, allergic complaints, skin rash, or gastrointestinal symptoms. Of these 44 patients, 29 (66%) exhibited at least 1 laboratory abnormality suggesting MCA disorder, and 11/29 patients had 2 or more such abnormalities. Elevated prostaglandins (n=16) or plasma histamine markers (n=23) were the most frequent findings. Thus, 42% (29/69) of patients initially diagnosed with POTS exhibited both additional symptoms and at least 1 elevated biochemical marker suggesting MCA disorder. Conclusions Laboratory findings suggesting MCA disorder were relatively common in patients diagnosed with POTS and who present with additional nonorthostatic gastrointestinal, cutaneous, and allergic symptoms. While solitary abnormal laboratory findings are not definitive, they favor MCA disorder being considered in such cases.


Asunto(s)
Trastornos de la Activación de los Mastocitos , Síndrome de Taquicardia Postural Ortostática , Enfermedades Gastrointestinales , Histamina/sangre , Humanos , Trastornos de la Activación de los Mastocitos/epidemiología , Síndrome de Taquicardia Postural Ortostática/epidemiología , Prostaglandinas/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA