Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Sensors (Basel) ; 23(19)2023 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-37836955

RESUMEN

Triangular resonators re-shaped with Sierpinski geometry were designed, manufactured, and tested for potential applications in the K-Band. Prototypes of band-stop filters working around 20 GHz and 26 GHz, interesting for RADAR and satellite communications, were studied in a coplanar waveguide (CPW) configuration. Single and coupled structures were analyzed to give evidence for: (i) the tuning of the resonance frequency by increasing the internal complexity of the triangle and (ii) resonance enhancement when coupled structures are considered. The exploited devices were part of the more extended family of metamaterial-inspired structures, and they were studied for their heuristic approach to the prediction of the spectrum using experimental results supported by electromagnetic simulations. As a result, a Sierpinski resonator, not only fed into but also fully embedded into a CPW environment, had a frequency response that was not easily determined by classical theoretical approaches.

2.
Sensors (Basel) ; 23(19)2023 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-37837168

RESUMEN

Triangular resonators re-shaped into Sierpinski geometry and U-shaped resonators were designed, linking them with single-pole-double-through (SPDT) RF MEMS switches to provide frequency tuning for potential applications in the K-Band. Prototypes of band-stop narrowband filters working around 20 GHz and 26 GHz, interesting for RADAR and satellite communications, were studied in a coplanar waveguide (CPW) configuration, and the tuning was obtained by switching between two paths of the devices loaded with different resonators. As a result, dual-band operation or fine-tuning could be obtained depending on the choice of the resonator, acting as a building block. The studied filters belong to the more general group of devices inspired by a metamaterial design.

3.
Sensors (Basel) ; 23(6)2023 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-36992071

RESUMEN

This work details an effective dynamic chemical etching technique to fabricate ultra-sharp tips for Scanning Near-Field Microwave Microscopy (SNMM). The protruded cylindrical part of the inner conductor in a commercial SMA (Sub Miniature A) coaxial connector is tapered by a dynamic chemical etching process using ferric chloride. The technique is optimized to fabricate ultra-sharp probe tips with controllable shapes and tapered down to have a radius of tip apex around ∼1 µm. The detailed optimization facilitated the fabrication of reproducible high-quality probes suitable for non-contact SNMM operation. A simple analytical model is also presented to better describe the dynamics of the tip formation. The near-field characteristics of the tips are evaluated by finite element method (FEM) based electromagnetic simulations and the performance of the probes has been validated experimentally by means of imaging a metal-dielectric sample using the in-house scanning near-field microwave microscopy system.

4.
Sensors (Basel) ; 23(1)2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36617066

RESUMEN

U-shaped microwave resonators implemented by RF MEMS switches can be considered the result of a novel design approach for obtaining small-footprint tunable resonators, owing to the bent shape of the resonator and the microsystem solution for changing the frequency of resonance. In this paper, we discuss the design approach for potential configurations of U-shaped structures combined with ohmic RF MEMS switches. Owing to their prospective application in RADAR and satellite systems, the devices were assessed for K-Band operation, specifically for 15 GHz, 20 GHz, and 26 GHz. The ON-OFF states determined by an electrostatic actuation of metal beams composing the RF MEMS ohmic switches allow for selecting different path lengths corresponding to different frequencies. In this contribution, initial configurations were designed and manufactured as a proof-of-concept. The advantages and critical aspects of the designs are discussed in detail.

5.
Rev Sci Instrum ; 87(5): 053701, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-27250429

RESUMEN

In this paper, we present in detail the design, both electromagnetic and mechanical, the fabrication, and the test of the first prototype of a Scanning Microwave Microscope (SMM) suitable for a two-port transmission measurement, recording, and processing the high frequency transmission scattering parameter S21 passing through the investigated sample. The S21 toolbox is composed by a microwave emitter, placed below the sample, which excites an electromagnetic wave passing through the sample under test, and is collected by the cantilever used as the detector, electrically matched for high frequency measurements. This prototype enhances the actual capability of the instrument for a sub-surface imaging at the nanoscale. Moreover, it allows the study of the electromagnetic properties of the material under test obtained through the measurement of the reflection (S11) and transmission (S21) parameters at the same time. The SMM operates between 1 GHz and 20 GHz, current limit for the microwave matching of the cantilever, and the high frequency signal is recorded by means of a two-port Vector Network Analyzer, using both contact and no-contact modes of operation, the latter, especially minded for a fully nondestructive and topography-free characterization. This tool is an upgrade of the already established setup for the reflection mode S11 measurement. Actually, the proposed setup is able to give richer information in terms of scattering parameters, including amplitude and phase measurements, by means of the two-port arrangement.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA