Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Interv Neurol ; 8(2-6): 123-134, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32508894

RESUMEN

BACKGROUND: Platelet inhibitors are used to prevent thromboembolic complications related to neurovascular stenting (NVS) procedures. Despite substantial inter-individual variability of functional platelet inhibition, the value of platelet function tests (PFT) to assess inhibition remains controversial. OBJECTIVE: This study was conducted to compare differences in thromboembolic complication rates associated with NVS in platelet-inhibited patients with and without PFT. Clinical neurological outcomes were assessed by differences in the modified Rankin Scale (mRS). MATERIALS AND METHODS: One hundred seventeen consecutive patients underwent elective NVS procedures within a 7-year period. All patients received aspirin and clopidogrel 8 days before the procedure. Fifty-two patients were treated without assessment of platelet inhibition, and 65 patients were tested for clopidogrel resistance. When clopidogrel resistance was revealed, corresponding patients were converted to ticagrelor. Changes in mRS and thromboembolic event rates were compared between the 2 cohorts. RESULTS: Thirty-five percent of patients from the cohort subjected to PFT tests showed inadequate platelet inhi-bition under clopidogrel and were converted to ticagrelor. Compared to the non-PFT test -cohort, neurological deficits were significantly reduced (12 vs. 0%; p = 0.009) and a lower number of thromboembolic events was found (12 vs. 3%; p > 0.05) within the test cohort. CONCLUSION: PFT appears to identify patients with clopidogrel resistance prior to NVS procedures. When non-responders are converted to alternative platelet inhibitors, neurological outcomes and thromboembolic complication rates may improve. Consequently, this study provides preliminary evidence that PFT may be a useful clinical tool to enhance procedural safety and improve clinical outcomes in NVS procedures.

2.
Interv Neuroradiol ; 26(1): 45-54, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31403834

RESUMEN

OBJECTIVE: Incomplete aneurysm occlusions and re-treatment rates of 52 and 10-30%, respectively, have been reported following endovascular treatment of intracranial aneurysms, raising clinical concerns regarding procedural efficacy. We compare residual, recurrence and re-treatment rates subject to different endovascular techniques in both ruptured and unruptured intracranial aneurysms at a comprehensive state-wide tertiary neurovascular centre in Australia. METHODS: Medical records, procedural and follow-up imaging studies of all patients who underwent endovascular treatment for intracranial aneurysms between July 2010 and July 2017 were reviewed retrospectively. Residuals, recurrences and re-treatment rates were assessed regarding initial aneurysm rupture status and applied endovascular technique: primary coiling, balloon- and stent-assisted coiling and flow diversion. RESULTS: Among 233 aneurysms, residual, recurrence and re-treatment rates were 27, 11.2 and 9.4%, respectively. Compared with unruptured aneurysms, similar residual and recurrence (p > .05), but higher re-treatment rates (4.5% vs. 19%; p < .001) were found for ruptured aneurysms. Residual, recurrence and re-treatment rates were: 13.3, 16 and 12% for primary coiling; 12, 12 and 10.7% for balloon-assisted coiling; 14.9, 7.5 and 4.5% for stent-assisted coiling; 91.9, 0 and 5.4% for flow diversion. Stent-assistance and flow-diversion were associated with lower recurrence and re-treatment rates, when compared with primary- and balloon-assisted coiling (p < .05). CONCLUSIONS: Residuals and recurrences after endovascular treatment of intracranial aneurysms are less common than previously reported. Stent assistance and flow diversion seem associated with reduced recurrence- and re-treatment rates, when compared with primary- and balloon-assisted coiling. Restrained use of stents in ruptured aneurysms may be a contributing factor for higher recurrence/retreatment rates compared to unruptured aneurysms.


Asunto(s)
Procedimientos Endovasculares/métodos , Aneurisma Intracraneal/cirugía , Retratamiento/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Aneurisma Roto/diagnóstico por imagen , Aneurisma Roto/cirugía , Angiografía de Substracción Digital , Femenino , Estudios de Seguimiento , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Stents , Resultado del Tratamiento
3.
J Neurointerv Surg ; 10(9): 902-906, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29317468

RESUMEN

BACKGROUND: Limited data are available for radiation exposure, and procedure and fluoroscopy times in neuroendovascular treatment (NET) strategies. OBJECTIVE: This study establishes and compares related parameters between coil embolization (COIL), balloon assisted coil embolization (BAC), stent assisted coil embolization (SAC), and flow diverting technology (FDT) in NET of intracranial aneurysms. MATERIALS AND METHODS: Between 2010 and 2017, 249 consecutive intracranial aneurysms underwent NET at a single center, all performed by the same operator. Dose area products (DAP), and procedure and fluoroscopy times were recorded and compared between COIL, BAC, SAC, and FDT techniques. Differences in parameters between cohorts were analyzed for significance using the Mann-Whitney U test, unpaired t test and χ2test. Additional subgroup analysis was performed for emergency and elective cases. RESULTS: 83 aneurysms were treated with COIL (33%), 72 with BAC (29%), 61 with SAC (25%), and 33 with FDT (13%). Baseline characteristics were largely similar within these groups (P>0.05). Among COIL, BAC, and FDT cohorts, no significant difference was found for mean DAP, or procedure and fluoroscopy times (P>0.05). However, compared with all other cohorts, SAC was associated with a significantly higher DAP and longer procedure and fluoroscopy times (P<0.005). No significant difference was recorded for emergency and elective case subgroups. CONCLUSION: Compared with other NET strategies, SAC was associated with a significantly higher DAP, and longer procedure and fluoroscopy times. This study provides an initial dataset regarding radiation exposure, and procedure and fluoroscopy times for common NET, and may assist ALARA (As Low As Reasonably Achievable) principles to reduce radiation risks.


Asunto(s)
Procedimientos Endovasculares/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Exposición a la Radiación , Stents Metálicos Autoexpandibles , Adulto , Anciano , Prótesis Vascular , Embolización Terapéutica/métodos , Femenino , Fluoroscopía/métodos , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
4.
World Neurosurg ; 91: 260-5, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27108026

RESUMEN

BACKGROUND: Prospective international cohort trials have suggested that incidental cerebral aneurysms with diameters less than 10 mm are unlikely to rupture. Consequently, small ruptured cerebral aneurysms should rarely be seen in clinical practice. To verify this theory, dimensions and locations of ruptured cerebral aneurysms were analyzed across the state of Tasmania, Australia. METHODS: We retrospectively reviewed medical records and diagnostic tests of all patients admitted with ruptured cerebral aneurysms during a 5-year interval. Aneurysm location, maximum size, dome-to-neck ratio, volume, and presence of daughter sacs were determined by preoperative digital subtraction angiography or computed tomography angiography. RESULTS: A total of 131 ruptured cerebral aneurysms were encountered and treated by microsurgical clipping (n = 59) or endovascular techniques (n = 72). The mean maximum aneurysm diameter was 6.4 ± 3.7 mm, dome-to-neck ratio 2 ± 0.8, aneurysm volume 156 ± 372 mm(3), and daughter sacs were present in 70 aneurysms (53.4%). The anterior communicating artery was the most common location (37.4%). Cumulative maximum diameters of ruptured aneurysms were ≤5 mm in 49%, ≤7 mm in 73%, and ≤10 mm in 90%. CONCLUSIONS: Despite findings from prospective international cohort trials, small ruptured intracranial aneurysms are common in clinical practice. In consequence, it seems important to identify those patients with small but vulnerable unruptured aneurysms before conservative management is considered.


Asunto(s)
Aneurisma Roto/diagnóstico por imagen , Angiografía Cerebral/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Aneurisma Roto/epidemiología , Aneurisma Roto/terapia , Angiografía de Substracción Digital , Angiografía por Tomografía Computarizada , Femenino , Humanos , Aneurisma Intracraneal/epidemiología , Aneurisma Intracraneal/terapia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tasmania/epidemiología , Adulto Joven
5.
Sci Rep ; 6: 30396, 2016 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-27477841

RESUMEN

We demonstrate heterodyne mixing of a 94 GHz millimetre wave photonic signal, supplied by a Gunn diode oscillator, with coherent acoustic waves of frequency ~100 GHz, generated by pulsed laser excitation of a semiconductor surface. The mixing takes place in a millimetre wave Schottky diode, and the intermediate frequency electrical signal is in the 1-12 GHz range. The mixing process preserves all the spectral content in the acoustic signal that falls within the intermediate frequency bandwidth. Therefore this technique may find application in high-frequency acoustic spectroscopy measurements, exploiting the nanometre wavelength of sub-THz sound. The result also points the way to exploiting acoustoelectric effects in photonic devices working at sub-THz and THz frequencies, which could provide functionalities at these frequencies, e.g. acoustic wave filtering, that are currently in widespread use at lower (GHz) frequencies.

6.
Biorheology ; 52(4): 279-91, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26518754

RESUMEN

BACKGROUND: Microcatheter directed blood reperfusion is an endovascular salvage option for acute cerebral artery occlusions. It has not been investigated whether this technique may be associated with hemolysis. OBJECTIVE: Analysis of hemolysis during blood infusion through different microcatheters and infusion rates to assess related risks. METHODS: Four microcatheters with different inner diameters were perfused with blood samples at three infusion rates. Hemolytic markers including lactate-dehydrogenase (LDH) and haptoglobin were analyzed. Samples before and after blood infusion were compared using Student's t-test. Flow-related degree of hemolysis was analyzed with regression analysis. Resulting shear stress was calculated and correlated with LDH and haptoglobin. RESULTS: Significant increase of LDH and decrease of haptoglobin was found after blood reperfusion through small microcatheters at progressive flow rates (p<0.05). No hemolysis was found with larger diameter microcatheters at all flow rates (p>0.05). Correlation between shear stress, LDH and haptoglobin was r=0.86 and r=0.75, respectively. CONCLUSIONS: Progressive hemolysis occurs during blood perfusion of small lumen microcatheters at increasing flow rates. This phenomenon may be related to turbulent flow, exposure time and increased shear stress. Larger microcatheters did not induce hemolysis and may be the preferred choice for stroke reperfusion.


Asunto(s)
Hemólisis , Dispositivos de Acceso Vascular/efectos adversos , Coagulación Sanguínea , Velocidad del Flujo Sanguíneo , Haptoglobinas/análisis , Humanos , L-Lactato Deshidrogenasa/sangre , Estrés Mecánico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA