Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 251
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-38445836

RESUMEN

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Asunto(s)
Síndrome de Brugada , Desfibriladores Implantables , Marcapaso Artificial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/diagnóstico , Síndrome de Brugada/complicaciones , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Electrocardiografía/métodos , Electrocardiografía Ambulatoria/métodos , Adulto
2.
Eur Heart J ; 45(7): 538-548, 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38195003

RESUMEN

BACKGROUND AND AIMS: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death (SCD) in arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to identify cross-continental differences in utilization of primary prevention ICDs and survival free from sustained ventricular arrhythmia (VA) in ARVC. METHODS: This was a retrospective analysis of ARVC patients without prior VA enrolled in clinical registries from 11 countries throughout Europe and North America. Patients were classified according to whether they received treatment in North America or Europe and were further stratified by baseline predicted VA risk into low- (<10%/5 years), intermediate- (10%-25%/5 years), and high-risk (>25%/5 years) groups. Differences in ICD implantation and survival free from sustained VA events (including appropriate ICD therapy) were assessed. RESULTS: One thousand ninety-eight patients were followed for a median of 5.1 years; 554 (50.5%) received a primary prevention ICD, and 286 (26.0%) experienced a first VA event. After adjusting for baseline risk factors, North Americans were more than three times as likely to receive ICDs {hazard ratio (HR) 3.1 [95% confidence interval (CI) 2.5, 3.8]} but had only mildly increased risk for incident sustained VA [HR 1.4 (95% CI 1.1, 1.8)]. North Americans without ICDs were at higher risk for incident sustained VA [HR 2.1 (95% CI 1.3, 3.4)] than Europeans. CONCLUSIONS: North American ARVC patients were substantially more likely than Europeans to receive primary prevention ICDs across all arrhythmic risk strata. A lower rate of ICD implantation in Europe was not associated with a higher rate of VA events in those without ICDs.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Displasia Ventricular Derecha Arritmogénica/complicaciones , Displasia Ventricular Derecha Arritmogénica/epidemiología , Displasia Ventricular Derecha Arritmogénica/terapia , Estudios Retrospectivos , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Factores de Riesgo , América del Norte/epidemiología , Europa (Continente)/epidemiología
3.
Eur Heart J ; 45(32): 2968-2979, 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39011630

RESUMEN

BACKGROUND AND AIMS: Pathogenic desmoplakin (DSP) gene variants are associated with the development of a distinct form of arrhythmogenic cardiomyopathy known as DSP cardiomyopathy. Patients harbouring these variants are at high risk for sustained ventricular arrhythmia (VA), but existing tools for individualized arrhythmic risk assessment have proven unreliable in this population. METHODS: Patients from the multi-national DSP-ERADOS (Desmoplakin SPecific Effort for a RAre Disease Outcome Study) Network patient registry who had pathogenic or likely pathogenic DSP variants and no sustained VA prior to enrolment were followed longitudinally for the development of first sustained VA event. Clinically guided, step-wise Cox regression analysis was used to develop a novel clinical tool predicting the development of incident VA. Model performance was assessed by c-statistic in both the model development cohort (n = 385) and in an external validation cohort (n = 86). RESULTS: In total, 471 DSP patients [mean age 37.8 years, 65.6% women, 38.6% probands, 26% with left ventricular ejection fraction (LVEF) < 50%] were followed for a median of 4.0 (interquartile range: 1.6-7.3) years; 71 experienced first sustained VA events {2.6% [95% confidence interval (CI): 2.0, 3.5] events/year}. Within the development cohort, five readily available clinical parameters were identified as independent predictors of VA and included in a novel DSP risk score: female sex [hazard ratio (HR) 1.9 (95% CI: 1.1-3.4)], history of non-sustained ventricular tachycardia [HR 1.7 (95% CI: 1.1-2.8)], natural logarithm of 24-h premature ventricular contraction burden [HR 1.3 (95% CI: 1.1-1.4)], LVEF < 50% [HR 1.5 (95% CI: .95-2.5)], and presence of moderate to severe right ventricular systolic dysfunction [HR 6.0 (95% CI: 2.9-12.5)]. The model demonstrated good risk discrimination within both the development [c-statistic .782 (95% CI: .77-.80)] and external validation [c-statistic .791 (95% CI: .75-.83)] cohorts. The negative predictive value for DSP patients in the external validation cohort deemed to be at low risk for VA (<5% at 5 years; n = 26) was 100%. CONCLUSIONS: The DSP risk score is a novel model that leverages readily available clinical parameters to provide individualized VA risk assessment for DSP patients. This tool may help guide decision-making for primary prevention implantable cardioverter-defibrillator placement in this high-risk population and supports a gene-first risk stratification approach.


Asunto(s)
Desmoplaquinas , Humanos , Desmoplaquinas/genética , Femenino , Masculino , Medición de Riesgo/métodos , Adulto , Persona de Mediana Edad , Arritmias Cardíacas/genética , Heterocigoto , Taquicardia Ventricular/genética
4.
Eur Heart J ; 2024 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-39288222

RESUMEN

BACKGROUND AND AIMS: Pathogenic variants in the desmoplakin (DSP) gene are associated with the development of a distinct arrhythmogenic cardiomyopathy phenotype not fully captured by either dilated cardiomyopathy (DCM), non-dilated left ventricular cardiomyopathy (NDLVC), or arrhythmogenic right ventricular cardiomyopathy (ARVC). Prior studies have described baseline DSP cardiomyopathy genetic, inflammatory, and structural characteristics. However, cohort sizes have limited full clinical characterization and identification of clinical and demographic predictors of sustained ventricular arrhythmias (VAs), heart failure (HF) hospitalizations, and transplant/death. In particular, the relevance of acute myocarditis-like episodes for subsequent disease course is largely unknown. METHODS: All patients with pathogenic/likely pathogenic (P/LP) DSP variants in the worldwide DSP-ERADOS Network (26 academic institutions across nine countries) were included. The primary outcomes were the development of sustained VA and HF hospitalizations during follow-up. Fine-Gray regressions were used to test association between clinical and instrumental parameters and the development of outcomes. RESULTS: Eight hundred patients [40.3 ± 17.5 years, 47.5% probands, left ventricular ejection fraction (LVEF) 49.5 ± 13.9%] were included. Over 3.7 [1.4-7.1] years, 139 (17.4%, 3.9%/year) and 72 (9.0%, 1.8%/year) patients experienced sustained VA and HF episodes, respectively. A total of 32.5% of individuals did not fulfil diagnostic criteria for ARVC, DCM, or NDLVC; their VA incidence was 0.5%/year. In multivariable regression, risk features associated with the development of VA were female sex [adjusted hazard ratio (aHR) 1.547; P = .025], prior non-sustained ventricular tachycardia (aHR 1.721; P = .009), prior sustained VA (aHR 1.923; P = .006), and LVEF ≤ 50% (aHR: 1.645; P = .032), while for HF, they were the presence of T-wave inversion in 3+ electrocardiogram leads (aHR 2.036, P = .007) and LVEF ≤ 50% (aHR 3.879; P < .001). Additionally, 70 (8.8%) patients experienced a myocardial injury episode at presentation or during follow-up. These episodes were associated with an increased risk of VA and HF thereafter (HR 2.394; P < .001, and HR 5.064, P < .001, respectively). CONCLUSIONS: Patients with P/LP DSP variants experience high rates of sustained VA and HF hospitalizations. These patients demonstrate a distinct clinical phenotype (DSP cardiomyopathy), whose most prominent risk features associated with adverse clinical outcomes are the presence of prior non-sustained ventricular tachycardia or sustained VA, T-wave inversion in 3+ leads on electrocardiogram, LVEF ≤ 50%, and myocardial injury events.

5.
J Cardiovasc Electrophysiol ; 35(6): 1101-1111, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38519418

RESUMEN

INTRODUCTION: Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS: Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Ablación por Catéter , Frecuencia Cardíaca , Venas Pulmonares , Recurrencia , Sistema de Registros , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Anciano , Estudios Prospectivos , Factores de Tiempo , Italia , Factores de Riesgo , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Resultado del Tratamiento , Supervivencia sin Progresión
6.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38584394

RESUMEN

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Asunto(s)
Ablación por Catéter , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Cardioversión Eléctrica/efectos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
7.
Eur Heart J ; 44(35): 3327-3335, 2023 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-37387689

RESUMEN

AIMS: Management of patients with atrial fibrillation (AF) and concomitant heart failure (HF) remains complex. The Antwerp score, based on four parameters [QRS >120 ms (2 points), known aetiology (2 points), paroxysmal AF (1 point), severe atrial dilation (1 point)] adequately estimated the probability of left ventricular ejection fraction (LVEF) recovery after AF ablation in a single-centre cohort. The present study aims to externally validate this prediction model in a large European multi-centre cohort. METHODS AND RESULTS: A total of 605 patients (61.1 ± 9.4 years, 23.8% females, 79.8% with persistent AF) with HF and impaired LVEF (<50%) undergoing AF ablation in 8 European centres were retrospectively identified. According to the LVEF changes at 12-month echocardiography, 427 (70%) patients fulfilled the '2021 Universal Definition of HF' criteria for LVEF recovery and were defined as 'responders'. External validation of the score yielded good discrimination and calibration {area under the curve 0.86 [95% confidence interval (CI) 0.82-0.89], P < .001; Hosmer-Lemeshow P = .29}. Patients with a score < 2 had a 93% probability of LVEF recovery as opposed to only 24% in patients with a score > 3. Responders experienced more often positive ventricular remodelling [odds ratio (OR) 8.91, 95% CI 4.45-17.84, P < .001], fewer HF hospitalizations (OR 0.09, 95% CI 0.05-0.18, P < .001) and lower mortality (OR 0.11, 95% CI 0.04-0.31, P < .001). CONCLUSION: In this multi-centre study, a simple four-parameter score predicted LVEF recovery after AF ablation in patients with HF and discriminated clinical outcomes. These findings support the use of the Antwerp score to standardize shared decision-making regarding AF ablation referral in future clinical studies.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Insuficiencia Cardíaca , Femenino , Humanos , Masculino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Volumen Sistólico , Función Ventricular Izquierda , Estudios Retrospectivos , Resultado del Tratamiento
8.
Medicina (Kaunas) ; 60(4)2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38674168

RESUMEN

The application of cardiac magnetic resonance (CMR) imaging in clinical practice has grown due to technological advancements and expanded clinical indications, highlighting its superior capabilities when compared to echocardiography for the assessment of myocardial tissue. Similarly, the utilization of implantable cardiac electronic devices (CIEDs) has significantly increased in cardiac arrhythmia management, and the requirements of CMR examinations in patients with CIEDs has become more common. However, this type of exam often presents challenges due to safety concerns and image artifacts. Until a few years ago, the presence of CIED was considered an absolute contraindication to CMR. To address these challenges, various technical improvements in CIED technology, like the reduction of the ferromagnetic components, and in CMR examinations, such as the introduction of new sequences, have been developed. Moreover, a rigorous protocol involving multidisciplinary collaboration is recommended for safe CMR examinations in patients with CIEDs, emphasizing risk assessment, careful monitoring during CMR, and post-scan device evaluation. Alternative methods to CMR, such as computed tomography coronary angiography with tissue characterization techniques like dual-energy and photon-counting, offer alternative potential solutions, although their diagnostic accuracy and availability do limit their use. Despite technological advancements, close collaboration and specialized staff training remain crucial for obtaining safe diagnostic CMR images in patients with CIEDs, thus justifying the presence of specialized centers that are equipped to handle these type of exams.


Asunto(s)
Desfibriladores Implantables , Imagen por Resonancia Magnética , Marcapaso Artificial , Humanos , Desfibriladores Implantables/normas , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/instrumentación , Arritmias Cardíacas/diagnóstico por imagen
9.
Medicina (Kaunas) ; 60(4)2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38674259

RESUMEN

Background and Objectives: Cardiac magnetic resonance (CMR) imaging has become an essential instrument in the study of cardiomyopathies; it has recently been integrated into the diagnostic workflow for cardiac amyloidosis (CA) with remarkable results. An additional emerging role is the stratification of the arrhythmogenic risk by scar analysis and the possibility of merging these data with electro-anatomical maps. This is made possible by using a software (ADAS 3D, Galgo Medical, Barcelona, Spain) able to provide 3D heart models by detecting fibrosis along the whole thickness of the myocardial walls. Little is known regarding the applications of this software in the wide spectrum of cardiomyopathies and the potential benefits have yet to be discovered. In this study, we tried to apply the ADAS 3D in the context of CA. Materials and Methods: This study was a retrospectively analysis of consecutive CMR imaging of patients affected by CA that were treated in our center (Marche University Hospital). Wherever possible, the data were processed with the ADAS 3D software and analyzed for a correlation between the morphometric parameters and follow-up events. The outcome was a composite of all-cause mortality, unplanned cardiovascular hospitalizations, sustained ventricular arrhythmias (VAs), permanent reduction in left ventricular ejection fraction, and pacemaker implantation. The secondary outcomes were the need for a pacemaker implantation and sustained VAs. Results: A total of 14 patients were deemed eligible for the software analysis: 8 patients with wild type transthyretin CA, 5 with light chain CA, and 1 with transthyretin hereditary CA. The vast majority of imaging features was not related to the composite outcome, but atrial wall thickening displayed a significant association with both the primary (p = 0.003) and the secondary outcome of pacemaker implantation (p = 0.003). The software was able to differentiate between core zones and border zones of scars, with the latter being the most extensively represented in all patients. Interestingly, in a huge percentage of CMR images, the software identified the highest degree of core zone fibrosis among the epicardial layers and, in those patients, we found a higher incidence of the primary outcome, without reaching statistical significance (p = 0.18). Channels were found in the scar zones in a substantial percentage of patients without a clear correlation with follow-up events. Conclusions: CMR imaging plays a pivotal role in cardiovascular diagnostics. Our analysis shows the feasibility and applicability of such instrument for all types of CA. We could not only differentiate between different layers of scars, but we were also able to identify the presence of fibrosis channels among the different scar zones. None of the data derived from the ADAS 3D software seemed to be related to cardiac events in the follow-up, but this might be imputable to the restricted number of patients enrolled in the study.


Asunto(s)
Amiloidosis , Cardiomiopatías , Cicatriz , Imagen por Resonancia Magnética , Humanos , Masculino , Proyectos Piloto , Femenino , Cardiomiopatías/diagnóstico por imagen , Amiloidosis/diagnóstico por imagen , Amiloidosis/complicaciones , Anciano , Cicatriz/diagnóstico por imagen , Estudios Retrospectivos , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Programas Informáticos
10.
Circulation ; 146(19): 1434-1443, 2022 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-36205131

RESUMEN

BACKGROUND: A novel risk calculator based on clinical characteristics and noninvasive tests that predicts the onset of clinical sustained ventricular arrhythmias (VA) in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) has been proposed and validated by recent studies. It remains unknown whether programmed ventricular stimulation (PVS) provides additional prognostic value. METHODS: All patients with a definite ARVC diagnosis, no history of sustained VAs at diagnosis, and PVS performed at baseline were extracted from 6 international ARVC registries. The calculator-predicted risk for sustained VA (sustained or implantable cardioverter defibrillator treated ventricular tachycardia [VT] or fibrillation, [aborted] sudden cardiac arrest) was assessed in all patients. Independent and combined performance of the risk calculator and PVS on sustained VA were assessed during a 5-year follow-up period. RESULTS: Two hundred eighty-eight patients (41.0±14.5 years, 55.9% male, right ventricular ejection fraction 42.5±11.1%) were enrolled. At PVS, 137 (47.6%) patients had inducible ventricular tachycardia. During a median of 5.31 [2.89-10.17] years of follow-up, 83 (60.6%) patients with a positive PVS and 37 (24.5%) with a negative PVS experienced sustained VA (P<0.001). Inducible ventricular tachycardia predicted clinical sustained VA during the 5-year follow-up and remained an independent predictor after accounting for the calculator-predicted risk (HR, 2.52 [1.58-4.02]; P<0.001). Compared with ARVC risk calculator predictions in isolation (C-statistic 0.72), addition of PVS inducibility showed improved prediction of VA events (C-statistic 0.75; log-likelihood ratio for nested models, P<0.001). PVS inducibility had a 76% [67-84] sensitivity and 68% [61-74] specificity, corresponding to log-likelihood ratios of 2.3 and 0.36 for inducible (likelihood ratio+) and noninducible (likelihood ratio-) patients, respectively. In patients with a ARVC risk calculator-predicted risk of clinical VA events <25% during 5 years (ie, low/intermediate subgroup), PVS had a 92.6% negative predictive value. CONCLUSIONS: PVS significantly improved risk stratification above and beyond the calculator-predicted risk of VA in a primary prevention cohort of patients with ARVC, mainly for patients considered to be at low and intermediate risk by the clinical risk calculator.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Prevención Primaria , Femenino , Humanos , Masculino , Arritmias Cardíacas/epidemiología , Displasia Ventricular Derecha Arritmogénica/epidemiología , Displasia Ventricular Derecha Arritmogénica/prevención & control , Muerte Súbita Cardíaca/epidemiología , Desfibriladores Implantables , Prevención Primaria/métodos , Medición de Riesgo/métodos , Factores de Riesgo , Volumen Sistólico , Taquicardia Ventricular/epidemiología , Función Ventricular Derecha , Adulto , Persona de Mediana Edad
11.
J Cardiovasc Electrophysiol ; 34(5): 1216-1227, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37087672

RESUMEN

INTRODUCTION: The assessment of the ventricular myocardial substrate critically depends on the size of mapping electrodes, their orientation with respect to wavefront propagation, and interelectrode distance. We conducted a dual-center study to evaluate the impact of microelectrode mapping in patients undergoing catheter ablation (CA) of ventricular tachycardia (VT). METHODS: We included 21 consecutive patients (median age, 68 [12], 95% male) with structural heart disease undergoing CA for electrical storm (n = 14) or recurrent VT (n = 7) using the QDOT Micro catheter and a multipolar catheter (PentaRay, n = 9). The associations of peak-to-peak maximum standard bipolar (BVc ) and minibipolar (PentaRay, BVp ) with microbipolar (BVµMax ) voltages were respectively tested in sinus rhythm with mixed effect models. Furthermore, we compared the features of standard bipolar (BE) and microbipolar (µBE) electrograms in sinus rhythm at sites of termination with radiofrequency energy. RESULTS: BVµMax was moderately associated with both BVc (ß = .85, p < .01) and BVp (ß = .56, p < .01). BVµMax was 0.98 (95% CI: 0.93-1.04, p < .01) mV larger than corresponding BVc , and 0.27 (95% CI: 0.16-0.37, p < .01) mV larger than matching BVp in sinus rhythm, with higher percentage differences in low voltage regions, leading to smaller endocardial dense scar (2.3 [2.7] vs. 12.1 [17] cm2 , p < .01) and border zone (3.2 [7.4] vs. 4.8 [20.1] cm2 , p = .03) regions in microbipolar maps compared to standard bipolar maps. Late potentials areas were nonsignificantly greater in microelectrode maps, compared to standard electrode maps. At sites of VT termination (n = 14), µBE were of higher amplitude (0.9 [0.8] vs. 0.4 [0.2] mV, p < .01), longer duration (117 [66] vs. 74 [38] ms, p < .01), and with greater number of peaks (4 [2] vs. 2 [1], p < .01) in sinus rhythm compared to BE. CONCLUSION: microelectrode mapping is more sensitive than standard bipolar mapping in the identification of viable myocytes in SR, and may facilitate recognition of targets for CA.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Masculino , Anciano , Femenino , Microelectrodos , Resultado del Tratamiento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/complicaciones , Arritmias Cardíacas/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Cicatriz
12.
J Cardiovasc Electrophysiol ; 34(5): 1257-1267, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36994907

RESUMEN

INTRODUCTION: The prediction of ventricular tachyarrhythmias among patients with implantable cardioverter defibrillators is difficult with available clinical tools. We sought to assess whether in patients with heart failure (HF) and reduced ejection fraction with defibrillators, physiological sensor-based HF status, as summarized by the HeartLogic index, could predict appropriate device therapies. METHODS: Five hundred and sixty-eight consecutive HF patients with defibrillators (n = 158, 28%) or cardiac resynchronization therapy-defibrillators (n = 410, 72%) were included in this prospective observational multicenter analysis. The association of both HeartLogic index and its physiological components with defibrillator shocks and overall appropriate therapies was assessed in regression and time-dependent Cox models. RESULTS: Over a follow-up of 25 (15-35) months, 122 (21%) patients received an appropriate device therapy (shock, n = 74, 13%), while the HeartLogic index crossed the threshold value (alert, HeartLogic ≥ 16) 1200 times (0.71 alerts/patient-year) in 370 (65%) subjects. The occurrence of ≥1 HeartLogic alert was significantly associated with both appropriate shocks (Hazard ratios [HR]: 2.44, 95% confidence interval [CI]: 1.49-3.97, p = .003), and any appropriate defibrillator therapies. In multivariable time-dependent Cox models, weekly IN-alert state was the strongest predictor of appropriate defibrillator shocks (HR: 2.94, 95% CI: 1.73-5.01, p < .001) and overall therapies. Compared with stable patients, patients with appropriate shocks had significantly higher values of HeartLogic index, third heart sound amplitude, and resting heart rate 30-60 days before device therapy. CONCLUSION: The HeartLogic index is an independent dynamic predictor of appropriate defibrillator therapies. The combined index and its individual physiological components change before the arrhythmic event occurs.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Taquicardia Ventricular , Disfunción Ventricular Izquierda , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones , Terapia de Resincronización Cardíaca/efectos adversos , Disfunción Ventricular Izquierda/terapia
13.
J Cardiovasc Electrophysiol ; 34(6): 1386-1394, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37194742

RESUMEN

INTRODUCTION: Brugada syndrome (BrS) has a dynamic ECG pattern that might be revealed by certain conditions such as fever. We evaluated the incidence and management of ventricular arrhythmias (VAs) related to COVID-19 infection and vaccination among BrS patients carriers of an implantable loop recorder (ILR) or implantable cardioverter-defibrillator (ICD) and followed by remote monitoring. METHODS: This was a multicenter retrospective study. Patients were carriers of devices with remote monitoring follow-up. We recorded VAs 6 months before COVID-19 infection or vaccination, during infection, at each vaccination, and up to 6-month post-COVID-19 or 1 month after the last vaccination. In ICD carriers, we documented any device intervention. RESULTS: We included 326 patients, 202 with an ICD and 124 with an ILR. One hundred and nine patients (33.4%) had COVID-19, 55% of whom developed fever. Hospitalization rate due to COVID-19 infection was 2.76%. After infection, we recorded only two ventricular tachycardias (VTs). After the first, second, and third vaccines, the incidence of non-sustained ventricular tachycardia (NSVT) was 1.5%, 2%, and 1%, respectively. The incidence of VT was 1% after the second dose. Six-month post-COVID-19 healing or 1 month after the last vaccine, we documented NSVT in 3.4%, VT in 0.5%, and ventricular fibrillation in 0.5% of patients. Overall, one patient received anti-tachycardia pacing and one a shock. ILR carriers had no VAs. No differences were found in VT before and after infection and before and after each vaccination. CONCLUSIONS: From this large multicenter study conducted in BrS patients, followed by remote monitoring, the overall incidence of sustained VAs after COVID-19 infection and vaccination is relatively low.


Asunto(s)
Síndrome de Brugada , COVID-19 , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/epidemiología , Síndrome de Brugada/terapia , Estudios Retrospectivos , Incidencia , COVID-19/diagnóstico , COVID-19/epidemiología , COVID-19/prevención & control , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/terapia , Sistema de Registros , Vacunación , Estudios de Seguimiento
14.
Europace ; 25(3): 1025-1034, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36635857

RESUMEN

AIMS: Little is known about patients with right bundle branch block (RBBB)-ventricular tachycardia (VT) and arrhythmogenic cardiomyopathy (ACM). Our aims were: (i) to describe electrocardiogram (ECG) characteristics of sinus rhythm (SR) and VT; (ii) to correlate SR with RBBB-VT ECGs; and (iii) to compare VT ECGs with electro-anatomic mapping (EAM) data. METHODS AND RESULTS: From the European Survey on ACM, 70 patients with spontaneous RBBB-VT were included. Putative left ventricular (LV) sites of origin (SOOs) were estimated with a VT-axis-derived methodology and confirmed by EAM data when available. Overall, 49 (70%) patients met definite Task Force Criteria. Low QRS voltage predominated in lateral leads (n = 37, 55%), but QRS fragmentation was more frequent in inferior leads (n = 15, 23%). T-wave inversion (TWI) was equally frequent in inferior (n = 28, 42%) and lateral (n = 27, 40%) leads. TWI in inferior leads was associated with reduced LV ejection fraction (LVEF; 46 ± 10 vs. 53 ± 8, P = 0.02). Regarding SOOs, the inferior wall harboured 31 (46%) SOOs, followed by the lateral wall (n = 17, 25%), the anterior wall (n = 15, 22%), and the septum (n = 4, 6%). EAM data were available for 16 patients and showed good concordance with the putative SOOs. In all patients with superior-axis RBBB-VT who underwent endo-epicardial VT activation mapping, VT originated from the LV. CONCLUSIONS: In patients with ACM and RBBB-VT, RBBB-VTs originated mainly from the inferior and lateral LV walls. SR depolarization and repolarization abnormalities were frequent and associated with underlying variants.


Asunto(s)
Cardiomiopatías , Taquicardia Ventricular , Humanos , Bloqueo de Rama , Taquicardia Ventricular/etiología , Taquicardia Ventricular/complicaciones , Ventrículos Cardíacos , Electrocardiografía , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico
15.
Eur Heart J Suppl ; 25(Suppl C): C258-C260, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37125284

RESUMEN

Ablation targets of persistent atrial fibrillation remain poorly understood nowadays: due to structural alterations of the left atrium, isolation of the pulmonary veins alone has proved ineffective. New ablation targets such as the posterior wall, coronary sinus, and left atrial appendage were then sought. A new catheter (QDOT Micro™) has recently been released, which has the potential to increase the safety and efficacy of the procedure: it is connected to a new radiofrequency generator that allows for temperature-controlled ablation by reducing power and increasing irrigation with the increase in tissue temperature and allows to deliver power up to 90 W for few seconds (very high-power short-duration).

16.
Eur Heart J ; 43(32): 3041-3052, 2022 08 21.
Artículo en Inglés | MEDLINE | ID: mdl-35766180

RESUMEN

AIMS: Arrhythmogenic right ventricular cardiomyopathy (ARVC) causes ventricular arrhythmias (VAs) and sudden cardiac death (SCD). In 2019, a risk prediction model that estimates the 5-year risk of incident VAs in ARVC was developed (ARVCrisk.com). This study aimed to externally validate this prediction model in a large international multicentre cohort and to compare its performance with the risk factor approach recommended for implantable cardioverter-defibrillator (ICD) use by published guidelines and expert consensus. METHODS AND RESULTS: In a retrospective cohort of 429 individuals from 29 centres in North America and Europe, 103 (24%) experienced sustained VA during a median follow-up of 5.02 (2.05-7.90) years following diagnosis of ARVC. External validation yielded good discrimination [C-index of 0.70 (95% confidence interval-CI 0.65-0.75)] and calibration slope of 1.01 (95% CI 0.99-1.03). Compared with the three published consensus-based decision algorithms for ICD use in ARVC (Heart Rhythm Society consensus on arrhythmogenic cardiomyopathy, International Task Force consensus statement on the treatment of ARVC, and American Heart Association guidelines for VA and SCD), the risk calculator performed better with a superior net clinical benefit below risk threshold of 35%. CONCLUSION: Using a large independent cohort of patients, this study shows that the ARVC risk model provides good prognostic information and outperforms other published decision algorithms for ICD use. These findings support the use of the model to facilitate shared decision making regarding ICD implantation in the primary prevention of SCD in ARVC.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Desfibriladores Implantables , Arritmias Cardíacas/etiología , Displasia Ventricular Derecha Arritmogénica/complicaciones , Displasia Ventricular Derecha Arritmogénica/diagnóstico , Displasia Ventricular Derecha Arritmogénica/terapia , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Humanos , Estudios Retrospectivos , Factores de Riesgo
17.
J Transl Med ; 20(1): 522, 2022 11 12.
Artículo en Inglés | MEDLINE | ID: mdl-36371290

RESUMEN

BACKGROUND: Cardiac mesenchymal stromal cells (C-MSC) were recently shown to differentiate into adipocytes and myofibroblasts to promote the aberrant remodeling of cardiac tissue that characterizes arrhythmogenic cardiomyopathy (ACM). A calcium (Ca2+) signaling dysfunction, mainly demonstrated in mouse models, is recognized as a mechanism impacting arrhythmic risk in ACM cardiomyocytes. Whether similar mechanisms influence ACM C-MSC fate is still unknown. Thus, we aim to ascertain whether intracellular Ca2+ oscillations and the Ca2+ toolkit are altered in human C-MSC obtained from ACM patients, and to assess their link with C-MSC-specific ACM phenotypes. METHODS AND RESULTS: ACM C-MSC show enhanced spontaneous Ca2+ oscillations and concomitant increased Ca2+/Calmodulin dependent kinase II (CaMKII) activation compared to control cells. This is manly linked to a constitutive activation of Store-Operated Ca2+ Entry (SOCE), which leads to enhanced Ca2+ release from the endoplasmic reticulum through inositol-1,4,5-trisphosphate receptors. By targeting the Ca2+ handling machinery or CaMKII activity, we demonstrated a causative link between Ca2+ oscillations and fibro-adipogenic differentiation of ACM C-MSC. Genetic silencing of the desmosomal gene PKP2 mimics the remodelling of the Ca2+ signalling machinery occurring in ACM C-MSC. The anti-arrhythmic drug flecainide inhibits intracellular Ca2+ oscillations and fibro-adipogenic differentiation by selectively targeting SOCE. CONCLUSIONS: Altogether, our results extend the knowledge of Ca2+ dysregulation in ACM to the stromal compartment, as an etiologic mechanism of C-MSC-related ACM phenotypes. A new mode of action of flecainide on a novel mechanistic target is unveiled against the fibro-adipose accumulation in ACM.


Asunto(s)
Cardiomiopatías , Células Madre Mesenquimatosas , Ratones , Animales , Humanos , Flecainida , Proteína Quinasa Tipo 2 Dependiente de Calcio Calmodulina , Miocitos Cardíacos , Calcio , Cardiomiopatías/genética
18.
J Cardiovasc Electrophysiol ; 33(5): 874-882, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35262242

RESUMEN

INTRODUCTION: Lesion Index (LSI) has been developed to predict lesion efficacy during radiofrequency (RF) catheter ablation. However, its value in predicting lesions size has still to be established. The aim of our study was to assess the lesions size reproducibility for prespecified values of LSI reached during RF delivery in an in vivo beating heart. METHODS: Ablation lesions were created with different values of LSI in seven domestic pigs by means of a contact force-sensing catheter (TactiCathTM , Abbott). Lesions were identified during RF delivery by means of a three-dimensional mapping system (EnSiteTM Precision, Abbott) and measured after heart explantation. Histology was carried out after gross examination on the first three lesions to confirm the accuracy of the macroscopic evaluation. RESULTS: A total of 64 myocardial lesions were created. Thirty-nine lesions were excluded from the analysis for the following reasons: histological confirmation of macroscopic lesion measurement (n = 3), transmurality (n = 24), unfavorable anatomic position (n = 10), not macroscopically identifiable (n = 2). In a final set of 25 nontransmural lesions, injury width and depth were, respectively, 4.6 ± 0.6 and 2.6 ± 0.8 mm for LSI = 4, 7.3 ± 0.8 and 4.7 ± 0.6 mm for LSI = 5, and 8.6 ± 1.2 and 7.2 ± 1.1 mm for LSI = 6. A strong linear correlation was observed between LSI and lesion width (r = .87, p < .00001) and depth (r = .89, p < .00001). Multiple linear regression analysis identified LSI as the only ablation parameter that significantly predicted lesion width (p < .001) and depth (p < .001). CONCLUSION: In our in vivo study, LSI proved highly predictive of lesion size and depth.


Asunto(s)
Ablación por Catéter , Animales , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Catéteres , Corazón , Humanos , Reproducibilidad de los Resultados , Sus scrofa , Porcinos
19.
Medicina (Kaunas) ; 59(1)2022 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-36676690

RESUMEN

Background. Data on leadless pacemaker (LPM) implantation in an emergency setting are currently lacking. Objective. We aimed to investigate the feasibility of LPM implantation for emergency bradyarrhythmia, in patients referred for urgent PM implantation, in a large, multicenter, real-world cohort of LPM recipients. Methods. Two cohorts of LPM patients, stratified according to the LPM implantation scenario (patients admitted from the emergency department (ED+) vs. elective patients (ED−)) were retrieved from the iLEAPER registry. The primary outcome of the study was a comparison of the peri-procedural complications between the groups. The rates of peri-procedural characteristics (overall procedural and fluoroscopic duration) were deemed secondary outcomes. Results. A total of 1154 patients were enrolled in this project, with patients implanted due to an urgent bradyarrhythmia (ED+) representing 6.2% of the entire cohort. Slow atrial fibrillation and complete + advanced atrioventricular blocks were more frequent in the ED+ cohort (76.3% for ED+ vs. 49.7% for ED−, p = 0.025; 37.5% vs. 27.3%, p = 0.027, respectively). The overall procedural times were longer in the ED+ cohort (60 (45−80) mins vs. 50 (40−65) mins, p < 0.001), showing higher rates of temporary pacing (94.4% for ED+ vs. 28.9% for ED−, p < 0.001). Emergency LPM implantation was not correlated with an increase in the rate of major complications compared to the control group (6.9% ED+ vs. 4.2% ED−, p = 0.244). Conclusion. LPM implantation is a feasible procedure for the treatment of severe bradyarrhythmia in an urgent setting. Urgent LPM implantation was not correlated with an increase in the rate of major complications compared to the control group, but it was associated with longer procedural times.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Humanos , Bradicardia/terapia , Fibrilación Atrial/terapia , Resultado del Tratamiento
20.
Circulation ; 142(13): 1249-1260, 2020 09 29.
Artículo en Inglés | MEDLINE | ID: mdl-32791857

RESUMEN

BACKGROUND: Electroanatomic voltage mapping (EVM) is a promising modality for guiding endomyocardial biopsies (EMBs). However, few data support its feasibility and safety. We now report the largest cohort of patients undergoing EVM-guided EMBs to show its diagnostic yield and to compare it with a cardiac magnetic resonance (CMR)-guided approach. METHODS: We included 162 consecutive patients undergoing EMB at our institution from 2010 to 2019. EMB was performed in pathological areas identified at EVM and CMR. CMR and EVM sensitivity and specificity regarding the identification of pathological substrates of myocardium were evaluated according to EMB results. RESULTS: Preoperative CMR showed late gadolinium enhancement in 70% of the patients, whereas EVM identified areas of low voltage in 61%. Right (73%), left (19%), or both ventricles (8%) underwent sampling. EVM proved to have sensitivity similar to CMR (74% versus 77%), with specificity being 70% and 47%, respectively. In 12 patients with EMB-proven cardiomyopathy, EVM identified pathological areas that had been undetected at CMR evaluation. Sensitivity of pooled EVM and CMR was as high as 95%. EMB analysis allowed us to reach a new diagnosis, different from the suspected clinical diagnosis, in 39% of patients. The complications rate was low, mostly related to vascular access, with no patients requiring urgent management. CONCLUSIONS: EVM proved to be a promising tool for targeted EMB because of its sensitivity and specificity for identification of myocardial pathological substrates. EVM was demonstrated to have accuracy similar to CMR. EVM and CMR together conferred a positive predictive value of 89% on EMB.


Asunto(s)
Medios de Contraste/administración & dosificación , Técnicas Electrofisiológicas Cardíacas , Gadolinio/administración & dosificación , Ventrículos Cardíacos , Imagen por Resonancia Magnética , Miocardio , Adulto , Biopsia , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA