Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
Intervalo de año de publicación
1.
Nature ; 570(7759): 102-106, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-31168103

RESUMEN

The Earth's crust-mantle boundary, the Mohorovicic discontinuity, has been traditionally considered to be the interface between the magnetic crust and the non-magnetic mantle1. However, this assumption has been questioned by geophysical observations2,3 and by the identification of magnetic remanence in mantle xenoliths4, which suggest mantle magnetic sources. Owing to their high critical temperatures, iron oxides are the only potential sources of magnetic anomalies at mantle depths5. Haematite (α-Fe2O3) is the dominant iron oxide in subducted lithologies at depths of 300 to 600 kilometres, delineated by the thermal decomposition of magnetite and the crystallization of a high-pressure magnetite phase deeper than about 600 kilometres6. The lack of data on the magnetic properties of haematite at relevant pressure-temperature conditions, however, hinders the identification of magnetic boundaries within the mantle and their contribution to observed magnetic anomalies. Here we apply synchrotron Mössbauer source spectroscopy in laser-heated diamond anvil cells to investigate the magnetic transitions and critical temperatures in Fe2O3 polymorphs7 at pressures and temperatures of up to 90 gigapascals and 1,300 kelvin, respectively. Our results show that haematite remains magnetic at the depth of the transition zone in the Earth's mantle in cold or very cold subduction geotherms, forming a frame of deep magnetized rocks in the West Pacific region. The deep magnetic sources spatially correlate with preferred paths of the Earth's virtual geomagnetic poles during reversals8 that might not reflect the geometry of the transitional field. Rather, the paths might be an artefact caused by magnetized haematite-bearing rocks in cold subducting slabs at mid-transition zone depths. Such deep sources should be taken into account when carrying out inversions of the Earth's geomagnetic data9, and especially in studies of planetary bodies that no longer have a dynamo10, such as Mars.

2.
J Synchrotron Radiat ; 28(Pt 3): 688-706, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33949979

RESUMEN

The high-precision X-ray diffraction setup for work with diamond anvil cells (DACs) in interaction chamber 2 (IC2) of the High Energy Density instrument of the European X-ray Free-Electron Laser is described. This includes beamline optics, sample positioning and detector systems located in the multipurpose vacuum chamber. Concepts for pump-probe X-ray diffraction experiments in the DAC are described and their implementation demonstrated during the First User Community Assisted Commissioning experiment. X-ray heating and diffraction of Bi under pressure, obtained using 20 fs X-ray pulses at 17.8 keV and 2.2 MHz repetition, is illustrated through splitting of diffraction peaks, and interpreted employing finite element modeling of the sample chamber in the DAC.

3.
Phys Rev Lett ; 126(10): 106001, 2021 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-33784165

RESUMEN

Extreme pressures and temperatures are known to drastically affect the chemistry of iron oxides, resulting in numerous compounds forming homologous series nFeOmFe_{2}O_{3} and the appearance of FeO_{2}. Here, based on the results of in situ single-crystal x-ray diffraction, Mössbauer spectroscopy, x-ray absorption spectroscopy, and density-functional theory+dynamical mean-field theory calculations, we demonstrate that iron in high-pressure cubic FeO_{2} and isostructural FeO_{2}H_{0.5} is ferric (Fe^{3+}), and oxygen has a formal valence less than 2. Reduction of oxygen valence from 2, common for oxides, down to 1.5 can be explained by a formation of a localized hole at oxygen sites.

4.
J Synchrotron Radiat ; 24(Pt 1): 269-275, 2017 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-28009566

RESUMEN

A method to separate the non-resonant inelastic X-ray scattering signal of a micro-metric sample contained inside a diamond anvil cell (DAC) from the signal originating from the high-pressure sample environment is described. Especially for high-pressure experiments, the parasitic signal originating from the diamond anvils, the gasket and/or the pressure medium can easily obscure the sample signal or even render the experiment impossible. Another severe complication for high-pressure non-resonant inelastic X-ray measurements, such as X-ray Raman scattering spectroscopy, can be the proximity of the desired sample edge energy to an absorption edge energy of elements constituting the DAC. It is shown that recording the scattered signal in a spatially resolved manner allows these problems to be overcome by separating the sample signal from the spurious scattering of the DAC without constraints on the solid angle of detection. Furthermore, simple machine learning algorithms facilitate finding the corresponding detector pixels that record the sample signal. The outlined experimental technique and data analysis approach are demonstrated by presenting spectra of the Si L2,3-edge and O K-edge of compressed α-quartz. The spectra are of unprecedented quality and both the O K-edge and the Si L2,3-edge clearly show the existence of a pressure-induced phase transition between 10 and 24 GPa.

5.
Nat Commun ; 15(1): 8256, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39313509

RESUMEN

H2O transforms to two forms of superionic (SI) ice at high pressures and temperatures, which contain highly mobile protons within a solid oxygen sublattice. Yet the stability field of both phases remains debated. Here, we present the results of an ultrafast X-ray heating study utilizing MHz pulse trains produced by the European X-ray Free Electron Laser to create high temperature states of H2O, which were probed using X-ray diffraction during dynamic cooling. We confirm an isostructural transition during heating in the 26-69 GPa range, consistent with the formation of SI-bcc. In contrast to prior work, SI-fcc was observed exclusively above ~50 GPa, despite evidence of melting at lower pressures. The absence of SI-fcc in lower pressure runs is attributed to short heating timescales and the pressure-temperature path induced by the pump-probe heating scheme in which H2O was heated above its melting temperature before the observation of quenched crystalline states, based on the earlier theoretical prediction that SI-bcc nucleates more readily from the fluid than SI-fcc. Our results may have implications for the stability of SI phases in ice-rich planets, for example during dynamic freezing, where the preferential crystallization of SI-bcc may result in distinct physical properties across mantle ice layers.

6.
Rev Sci Instrum ; 94(3): 033501, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37012789

RESUMEN

A multipurpose imaging x-ray crystal spectrometer is developed for the high energy density instrument of the European X-ray Free Electron Laser. The spectrometer is designed to measure x rays in the energy range of 4-10 keV, providing high-resolution, spatially resolved spectral measurements. A toroidally bent germanium (Ge) crystal is used, allowing x-ray diffraction from the crystal to image along a one-dimensional spatial profile while spectrally resolving along the other. A detailed geometrical analysis is performed to determine the curvature of the crystal. The theoretical performance of the spectrometer in various configurations is calculated by ray-tracing simulations. The key properties of the spectrometer, including the spectral and spatial resolution, are demonstrated experimentally on different platforms. Experimental results prove that this Ge spectrometer is a powerful tool for spatially resolved measurements of x-ray emission, scattering, or absorption spectra in high energy density physics.

7.
Rev Sci Instrum ; 92(1): 013101, 2021 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-33514249

RESUMEN

We introduce a setup to measure high-resolution inelastic x-ray scattering at the High Energy Density scientific instrument at the European X-Ray Free-Electron Laser (XFEL). The setup uses the Si (533) reflection in a channel-cut monochromator and three spherical diced analyzer crystals in near-backscattering geometry to reach a high spectral resolution. An energy resolution of 44 meV is demonstrated for the experimental setup, close to the theoretically achievable minimum resolution. The analyzer crystals and detector are mounted on a curved-rail system, allowing quick and reliable changes in scattering angle without breaking vacuum. The entire setup is designed for operation at 10 Hz, the same repetition rate as the high-power lasers available at the instrument and the fundamental repetition rate of the European XFEL. Among other measurements, it is envisioned that this setup will allow studies of the dynamics of highly transient laser generated states of matter.

8.
Sci Rep ; 10(1): 14564, 2020 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-32884061

RESUMEN

We present a method to determine the bulk temperature of a single crystal diamond sample at an X-Ray free electron laser using inelastic X-ray scattering. The experiment was performed at the high energy density instrument at the European XFEL GmbH, Germany. The technique, based on inelastic X-ray scattering and the principle of detailed balance, was demonstrated to give accurate temperature measurements, within [Formula: see text] for both room temperature diamond and heated diamond to 500 K. Here, the temperature was increased in a controlled way using a resistive heater to test theoretical predictions of the scaling of the signal with temperature. The method was tested by validating the energy of the phonon modes with previous measurements made at room temperature using inelastic X-ray scattering and neutron scattering techniques. This technique could be used to determine the bulk temperature in transient systems with a temporal resolution of 50 fs and for which accurate measurements of thermodynamic properties are vital to build accurate equation of state and transport models.

9.
Sci Rep ; 9(1): 4464, 2019 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-30872759

RESUMEN

The magnetite Fe3O4, being anciently known magnetic material to human kind and remaining in leading positions for development of advanced technologies presently, demonstrates a number of puzzling physical phenomena, being at focus of extensive research for more than century. Recently the pressure-induced anomalous behavior of physical properties of magnetite in vicinity of the structural phase transition, occurring at P ~ 25-30 GPa, has attracted particular attention, and its nature remains unclear. Here we study the magnetic and electronic properties of magnetite across high pressure anomaly and in the pressure-induced phase by means of 57Fe synchrotron Moessbauer spectroscopy and neutron diffraction. The hyperfine interaction parameters behavior was systematically analysed over pressure 0-40 GPa and temperature 10-290 K ranges. In the high pressure phase the ferrimagnetic order formation below TNP ~ 420 K was observed and spin arrangement symmetry was deduced. The structural, magnetic and electronic phase diagram of magnetite in the discussed pressure range is established.

10.
Nat Commun ; 9(1): 4554, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-30385756

RESUMEN

Iron oxides are among the major constituents of the deep Earth's interior. Among them, the epsilon phase of Fe2O3 is one of the less studied polymorphs and there is a lack of information about its structural, electronic and magnetic transformations at extreme conditions. Here we report the precise determination of its equation of state and a deep analysis of the evolution of the polyhedral units under compression, thanks to the agreement between our experiments and ab-initio simulations. Our results indicate that this material, with remarkable magnetic properties, is stable at pressures up to 27 GPa. Above 27 GPa, a volume collapse has been observed and ascribed to a change of the local environment of the tetrahedrally coordinated iron towards an octahedral coordination, finding evidence for a different iron oxide polymorph.

11.
Rev Sci Instrum ; 88(8): 084501, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28863683

RESUMEN

A portable double-sided pulsed laser heating system for diamond anvil cells has been developed that is able to stably produce laser pulses as short as a few microseconds with repetition frequencies up to 100 kHz. In situ temperature determination is possible by collecting and fitting the thermal radiation spectrum for a specific wavelength range (particularly, between 650 nm and 850 nm) to the Planck radiation function. Surface temperature information can also be time-resolved by using a gated detector that is synchronized with the laser pulse modulation and space-resolved with the implementation of a multi-point thermal radiation collection technique. The system can be easily coupled with equipment at synchrotron facilities, particularly for nuclear resonance spectroscopy experiments. Examples of applications include investigations of high-pressure high-temperature behavior of iron oxides, both in house and at the European Synchrotron Radiation Facility using the synchrotron Mössbauer source and nuclear inelastic scattering.

13.
Rev Sci Instrum ; 86(11): 114501, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26628151

RESUMEN

Developments in pulsed laser heating applied to nuclear resonance techniques are presented together with their applications to studies of geophysically relevant materials. Continuous laser heating in diamond anvil cells is a widely used method to generate extreme temperatures at static high pressure conditions in order to study the structure and properties of materials found in deep planetary interiors. The pulsed laser heating technique has advantages over continuous heating, including prevention of the spreading of heated sample and/or the pressure medium and, thus, a better stability of the heating process. Time differentiated data acquisition coupled with pulsed laser heating in diamond anvil cells was successfully tested at the Nuclear Resonance beamline (ID18) of the European Synchrotron Radiation Facility. We show examples applying the method to investigation of an assemblage containing ε-Fe, FeO, and Fe3C using synchrotron Mössbauer source spectroscopy, FeCO3 using nuclear inelastic scattering, and Fe2O3 using nuclear forward scattering. These examples demonstrate the applicability of pulsed laser heating in diamond anvil cells to spectroscopic techniques with long data acquisition times, because it enables stable pulsed heating with data collection at specific time intervals that are synchronized with laser pulses.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA