Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Int J Clin Pract ; 2024: 6219301, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38390376

RESUMEN

Background: Rates of major bleeding and intraprocedural thrombotic events (IPTE) in the setting of percutaneous coronary intervention (PCI) using weight-adjusted unfractionated heparin (UFH) without activated clotting time (ACT) monitoring are not known. Methods: We reviewed 2,748 consecutive patients who underwent coronary angiography at our tertiary care university hospital between January 2017 and December 2020. All patients who underwent PCI with weight-adjusted UFH without ACT guidance were considered for further analysis. Major bleeding complications occurring within 48 hours of PCI were collected from patients' medical records. IPTE were collected independently by two interventional cardiologists after review of coronary angiograms. Results: There were 718 patients included in the analysis (65.4 ± 12.2 years old; 81.3% male). In total, 45 patients (7.8%) experienced a major bleed or IPTE. The most common IPTE were slow/no reflow (1.5%) and coronary artery dissection with decreased flow (1.1%). Other IPTE occurred in <1% of cases. Major bleeding occurred in 11 patients (1.5%), of whom 8 required blood transfusion and 3 required vascular intervention. Bleeding complications were more common with femoral compared with radial access (6.6% vs. 0.2%, P < 0.001). Conclusion: Weight-adjusted UFH use during PCI without ACT monitoring was related to low rates of major bleeding or IPTE.


Asunto(s)
Intervención Coronaria Percutánea , Trombosis , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Heparina/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento , Hemorragia/inducido químicamente , Anticoagulantes/efectos adversos
2.
Interact Cardiovasc Thorac Surg ; 34(6): 966-973, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-34687533

RESUMEN

OBJECTIVES: The goal of this study was to assess the performance and incidence of the deterioration of the Labcor Dokimos bioprosthetic aortic valve. METHODS: We performed a retrospective medical chart review of 116 patients who underwent surgical aortic valve replacement with the Labcor Dokimos aortic valve between 2010 and 2018. Abstracted data included patient demographic and echocardiographic data. Patients were divided into 2 groups: patients with structural valve deterioration (SVD) and patients without SVD. RESULTS: Among the patients with complete follow-up (n = 95), 10 patients were excluded because they died within a year; 85 patients were included in the final analysis. Of the 85 patients, 32 (38%) developed SVD; 22 (26%) had severe SVD, 15 (18%) of whom underwent reintervention. The most common aetiology of SVD was severe central aortic regurgitation, which was detected in 91% of the patients who had severe SVD. The average time from operation to severe SVD was 4.7 years with a minimum of 1.5 years and a maximum of 7.9 years. CONCLUSIONS: Bioprosthetic aortic valve deterioration due to severe aortic regurgitation is common and occurs early with the Labcor Dokimos valve. This occurrence needs to be furthered investigated in larger registries.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Diseño de Prótesis , Falla de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA