1.
Europace ; 2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38875490

RESUMEN

AIMS: Superior vena cava (SVC) isolation during atrial fibrillation (AF) catheter ablation is limited by the risk of collateral damage to the sinus node and/or the phrenic nerve. Due to its tissue-specificity, we hypothesized the feasibility and safety of pulsed-field ablation (PFA)-based SVC isolation. METHODS AND RESULTS: A hundred and five consecutive patients undergoing PFA-based AF catheter ablation were prospectively included. After pulmonary vein isolation (± posterior wall isolation and electrical cardioversion), SVC isolation was performed using a standardized workflow. Acute SVC isolation was achieved in 105/105 (100%) patients after 6 ± 1 applications. Transient phrenic nerve stunning occurred in 67/105 (64%) patients but without phenic nerve palsy at the end of the procedure and at hospital discharge. Transient high degree sinus node dysfunction occurred in 5/105 (4.7%) patients, with no recurrence at the end of the procedure and until discharge. At the 3-month follow-up visit, no complication occurred. CONCLUSION: SVC isolation using a pentaspline PFA catheter is feasible and safe.

2.
J Cardiovasc Electrophysiol ; 34(4): 833-840, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36786515

RESUMEN

INTRODUCTION: Pulmonary vein isolation (PVI) is well established as a primary treatment for atrial fibrillation (AF). The POLAR ICE study was designed to collect prospective real world data on the safety and effectiveness of the POLARxTM cryoballoon for PVI to treat paroxysmal AF. METHODS: POLAR ICE, a prospective, non-randomized, multicenter (international) registry (NCT04250714), enrolled 399 patients across 19 European centers. Procedural characteristics, such as time to isolation, cryoablations per pulmonary vein (PV), balloon nadir temperature, and occlusion grade were recorded. PVI was confirmed with entrance block testing. RESULTS: Data on 372 de novo PVI procedures (n = 2190 ablations) were collected. Complete PVI was achieved in 96.8% of PVs. Procedure and fluoroscopy times were 68.2 ± 24.6 and 15.6 ± 9.6 min, respectively. Left atrial dwell time was 46.6 ± 18.3 min. Grade 3 or 4 occlusion was achieved in 98.2% of PVs reported and 71.2% of PVs isolation required only a single cryoablation. Of 2190 cryoapplications, 83% had a duration of at least 120 s; nadir temperature of these ablations averaged -56.3 ± 6.5°C. There were 6 phrenic nerve palsy events, 2 of which resolved within 3 months of the procedure. CONCLUSION: This real-world usage data on a novel cryoballoon suggests this device is effective, safe, and relatively fast in centers with cryoballoon experience. These data are comparable to prior POLARx reports and in keeping with reported data on other cryoballoons. Future studies should examine the long-term outcomes and the relationship between biophysical parameters and outcomes for this novel cryoballoon.


Asunto(s)
Fibrilación Atrial , Humanos , Fibrilación Atrial/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Atrios Cardíacos , Fluoroscopía
3.
Eur Heart J ; 43(47): 4887-4896, 2022 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-36303402

RESUMEN

AIMS: Sudden cardiac arrest remains a major complication of acute myocardial infarction (AMI) and is frequently related to ventricular fibrillation (VF). Incidence and impact of VF among patients hospitalized for AMI were evaluated. METHODS AND RESULTS: Data from the FAST-MI programme consisting of 5 French nationwide prospective cohort studies between 1995 and 2015 were analysed, totally including 14 423 patients with AMI (66 ± 14 years, 72% males, 59% ST-elevation myocardial infarction). Overall, proportion of patients presenting in-hospital VF decreased from 3.9% in 1995 to 1.8% in 2015 (P < 0.001). One-year mortality decreased from 60.7% to 24.6% (P < 0.001). However, compared with patients who did not develop VF, the over-risk of 1-year mortality associated with VF was stable over time [hazard ratio (HR) 6.78, 95% confidence interval (CI) 5.03-9.14 in 1995 and HR 6.64, 95% CI 4.20-10.49 in 2015, P = 0.52]. This increased mortality in the VF group was mainly related to fatal events occurring prior to hospital discharge, representing 86.2% of 1-year mortality, despite the very low rate of implantable cardioverter defibrillator in the VF group (2.6%). CONCLUSION: This study demonstrates that in-hospital VF incidence and mortality in the setting of AMI have significantly decreased over the past 20 years. Nevertheless, VF remained steadily associated with approximately a 10-fold increased relative risk of in-hospital mortality, without an impact on post-discharge mortality. Beyond long-term cardiac defibrillation strategy, these results emphasize the need to identify in-hospital interventions to further reduce mortality in VF patients. STUDY REGISTRATION: ClinicalTrials.gov Identifier: NCT00673036, NCT01237418, NCT02566200.


Asunto(s)
Infarto del Miocardio , Fibrilación Ventricular , Masculino , Humanos , Femenino , Fibrilación Ventricular/epidemiología , Fibrilación Ventricular/etiología , Fibrilación Ventricular/terapia , Estudios Prospectivos , Cuidados Posteriores , Alta del Paciente , Infarto del Miocardio/complicaciones , Infarto del Miocardio/epidemiología , Infarto del Miocardio/terapia , Factores de Riesgo
4.
J Cardiovasc Electrophysiol ; 32(2): 545-546, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33058383

RESUMEN

The IntellaMap OrionTM (Boston Scientific) is a 64-electrode basket catheter allowing for ultrahigh-density mapping of complex cardiac arrhythmias. We report the case of a basket catheter vascular entrapment, requiring surgical removal.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Arritmias Cardíacas/cirugía , Ablación por Catéter/efectos adversos , Catéteres , Electrodos , Diseño de Equipo , Humanos
5.
J Cardiovasc Magn Reson ; 22(1): 48, 2020 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-32580786

RESUMEN

BACKGROUND: The left ventricular ejection fraction (LVEF) is the key selection criterion for an implanted cardioverter defibrillator (ICD) in primary prevention of sudden cardiac death. LVEF is usually assessed by two-dimensional echocardiography, but cardiovascular magnetic resonance (CMR) imaging is increasingly used. The aim of our study was to evaluate whether LVEF assessment using CMR imaging (CMR-LVEF) or two-dimensional echocardiography (2D echo-LVEF) may predict differently the occurrence of clinical outcomes. METHODS: In this retrospective study, we reviewed patients referred for primary prevention ICD implantation to Caen University Hospital from 2005 to 2014. We included 173 patients with either ischemic (n = 120) or dilated cardiomyopathy (n = 53) and who had undergone pre-ICD CMR imaging. The primary composite end point was the time to death from any cause or first appropriate device therapy. RESULTS: The mean CMR-LVEF was significantly lower than the mean 2D echo-LVEF (24% ± 6 vs 28% ± 6, respectively; p < 0.001). CMR-LVEF was a better independent predictive factor for the occurrence of the primary composite endpoint with a cut-off value of 22% (Hazard Ratio [HR] = 2.22; 95% CI [1.34-3.69]; p = 0.002) than 2D echo-LVEF with a cut-off value of 26% (HR = 1.61; 95% CI [0.99-2.61]; p = 0.056). Combination of the presence of scar with CMR-LVEF< 22% improved the predictive value for the occurrence of the primary outcome (HR = 2.58; 95% CI [1.54-4.30]; p < 0.001). The overall survival was higher among patients with CMR-LVEF≥22% than among patients with CMR-LVEF< 22% (p = 0.026), whereas 2D echo-LVEF was not associated with death. CONCLUSIONS: CMR-LVEF is better associated with clinical outcomes than 2D echo-LVEF in primary prevention using an ICD. Scar identification further improved the outcome prediction. The combination of CMR imaging and echocardiography should be encouraged in addition to other risk markers to better select patients.


Asunto(s)
Cardiomiopatías/terapia , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Ecocardiografía , Cardioversión Eléctrica/instrumentación , Imagen por Resonancia Cinemagnética , Prevención Primaria/instrumentación , Volumen Sistólico , Función Ventricular Izquierda , Anciano , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/mortalidad , Cardiomiopatías/fisiopatología , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Francia , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
6.
Europace ; 22(4): 649-656, 2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-32097452

RESUMEN

AIMS: Limited data exist concerning fragmented QRS complexes (fQRSs) on the surface electrocardiogram (ECG) of apparently healthy athletes. We aimed to study the prevalence and significance of fQRS in lead V1 (fQRSV1), representing right ventricular (RV) activation, regarding training-induced RV morphological remodelling. METHODS AND RESULTS: Between January 2017 and August 2019, 434 consecutive non-sedentary subjects underwent preparticipation cardiovascular screening, including a 12-lead ECG. Three hundred and ninety-three apparently healthy subjects were included, 119 of them were athletes (defined as performing ≥8 h/week for the last 6 months) and 274 were non-athletes. All athletes underwent two-dimensional transthoracic echocardiography. Fragmented QRS complex in lead V1 pattern was defined as a narrow (<120 ms) and quadriphasic QRS complex in lead V1. Fragmented QRS complex in lead V1 was more frequent in athletes compared with non-athletes (22% vs. 5.1%, P < 0.001) and was independently associated with the athlete status [adjusted odds ratio (aOR) = 4.693, 95% confidence interval (95% CI) 2.299-9.583; P < 0.001], the endurance category (aOR = 2.522, 95% CI 1.176-5.408; P = 0.017), and age (aOR = 0.962, 95% CI 0.934-0.989; P = 0.007) in multivariate analysis. In the subgroup of athletes, fQRSV1 was independently associated with mean RV outflow tract diameter (aOR = 1.458, 95% CI 1.105-1.923; P = 0.008) and age (aOR = 0.941, 95% CI 0.894-0.989; P = 0.017) in multivariate analysis. CONCLUSION: Fragmented QRS complex in lead V1 is a newly described, frequent, ECG pattern in young and apparently healthy athletes and is associated with training-induced RV remodelling.


Asunto(s)
Atletas , Electrocardiografía , Ecocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Prevalencia
7.
Europace ; 22(11): 1628-1634, 2020 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-32830226

RESUMEN

AIMS: No data exist concerning the clinical performances of the subcutaneous implantable cardioverter-defibrillator (S-ICD) atrial fibrillation (AF) detection algorithm. We aimed to study the performances and implications of the latter in a 'real-world' setting. METHODS AND RESULTS: Between July 2017 and August 2019, 155 consecutive S-ICD recipients were included. Endpoint of the study was the incidence of de novo or recurrent AF using a combined on-site and remote-monitoring follow-up approach. After a mean follow-up of 13 ± 8 months, 2531 AF alerts were generated for 55 patients. A blinded analysis of the 1950 subcutaneous electrocardiograms available was performed. Among them 47% were true AF, 23% were premature atrial contractions or non-sustained AF, 29% were premature ventricular contractions or non-sustained ventricular tachycardia, and 1% were misdetection. Fourteen percent (21/155) patients had at least one correct diagnosis of AF by the S-ICD algorithm. One patient presented symptomatic paroxysmal AF not diagnosed by the S-ICD algorithm (false negative patient). Patient-based sensitivity, specificity, positive, and negative predictive values were respectively 95%, 74%, 38%, and 99%. Among patients with at least one correct diagnosis of AF, 38% (8/21) had subsequent clinical implications (anticoagulation initiation or rhythm control therapies). CONCLUSION: The S-ICD AF detection algorithm yields a high sensitivity for AF diagnosis. Low specificity and positive predictive value contribute to a high remote monitoring-notification workload and underline the necessity of a manual analysis. Atrial fibrillation diagnosis by the S-ICD AF detection algorithm might lead to significant therapeutic adjustments.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Electrocardiografía , Humanos , Valor Predictivo de las Pruebas
9.
Heart Vessels ; 34(5): 801-808, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30456724

RESUMEN

Ultra-high-density mapping allows very accurate characterization of circuits/mechanisms in atrial tachycardia (AT). Whether these advantages will translate into a better procedural or long-term clinical outcome is unknown. Sixty consecutive AT ablation procedures using ultra-high-density mapping (Rhythmia™, group 1) were retrospectively compared to 60 consecutive procedures using standard high-density mapping (Carto/NavX™, group 2) (total 209 AT, 79% left AT). A higher number of maps were performed in group 1 (4.8 ± 2.5 vs 3.2 ± 1.7, p = 0.0001) with similar acquisition duration (12 ± 5 vs 13 ± 6 min per map, p = ns), although with a greater number of activation points (10,543 ± 5854 vs 689 ± 1827 per map, p < 0.0001). AT location remained undetermined in 5 AT in group 1 vs 10 (p = 0.1). Mechanism remained undetermined in 5 AT from group 1 vs 11 (p = 0.06). Acute complete success was achieved in 77%, in both groups. At 1-year follow-up, AT recurred in 37% in group 1 vs 50% in group 2 (p = 0.046). There are less long-term recurrences after AT ablation using ultra-high-density mapping system compared to standard high-density 3D mapping, possibly because of a better comprehensive approach of AT mechanisms.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/instrumentación , Ablación por Catéter , Sistema de Conducción Cardíaco/cirugía , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Anciano , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Imagen Multimodal , Radiografía Intervencional , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
10.
BMC Geriatr ; 19(1): 325, 2019 11 21.
Artículo en Inglés | MEDLINE | ID: mdl-31752707

RESUMEN

BACKGROUND: Cardiac resynchronization therapy has been shown to benefit selected patients with heart failure and reduced ejection fraction. Older patients have been underrepresented in randomized trials. This study was conducted to determine whether predictive factors for cardiac resynchronization therapy outcomes differ in patients older and younger than 75 years of age. METHODS: Consecutive patients who received a cardiac resynchronization device cardiac resynchronization therapy between 2013 and 2016 in our center were retrospectively included in this cohort study. The primary endpoint was cardiac resynchronization therapy effectiveness, which was defined as survival for one year with both no heart failure hospitalization and improvement by one or more NYHA class. The secondary endpoints were mortality, complications, and device therapies. RESULTS: Among the 243 patients included, 102 were ≥ 75 years old. Cardiac resynchronization therapy effectiveness was observed in 70 patients (50%) < 75 years old and in 48 patients (47%) ≥75 years old (p = 0.69). NYHA class ≥III (OR = 6.02; CI95% [1.33-18.77], p = 0.002) was a predictive factor for cardiac resynchronization therapy effectiveness only in the ≥75-year-old group, while atrial fibrillation was independently negatively associated with the primary endpoint in the < 75-year-old group (OR = 0.28; CI95% [0.13-0.62], p = 0.001). The one-year mortality rate was 14%, with no difference between age groups. Rescue cardiac resynchronization therapy and atrial fibrillation were independent predictive factors for mortality in both age groups. Eighty-two complications occurred in 45 patients (19%), with no difference between groups. Defibrillator use and QRS duration were independent predictive factors for complications in both age groups. There was no difference between groups considering device therapies. CONCLUSION: At one year, cardiac resynchronization therapy response is not compromised by patient age. In older patients, highly symptomatic individuals with NYHA class ≥III have better outcomes after cardiac resynchronization therapy.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/terapia , Factores de Edad , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Fibrilación Atrial/mortalidad , Fibrilación Atrial/terapia , Desfibriladores Implantables , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Selección de Paciente , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento
16.
Europace ; 16(2): 220-6, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24186956

RESUMEN

AIMS: After an old myocardial infarction (MI), patients are at risk for reentrant ventricular tachycardia (VT) due to scar tissue that can be accurately identified by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR). Although the ability of LGE-CMR to predict sustained VT in implantable cardioverter-defibrillator (ICD) recipients has been well established, its use to predict monomorphic VT (sustained or not) cycle length (CL) and so, optimize ICD programming has never been investigated. METHODS AND RESULTS: We included retrospectively 49 consecutive patients with an old MI who had undergone LGE-CMR before ICD implantation over a 4-year period (2006-09). Patients with amiodarone used were excluded. Scar extent was assessed by measuring scar mass, percent scar, and transmural scar extent. The endpoint was the occurrence of monomorphic VT, requiring an ICD therapy or not. The endpoint occurred in 26 patients. The median follow-up duration was 31 months. Scar extent parameters were significantly correlated with the study endpoint. With univariate regression analysis, the scar mass had the highest correlation with the VT CL (R = 0.671, P = 0.0002). Receiver-operating characteristic curve showed that scar mass can predict VT CL (area under the curve = 0.977, P < 0.0001). For a cut-off value of scar mass at 17.6 g, there is 100% specificity and 94.4% sensitivity. CONCLUSION: In this observational and retrospective study, scar mass studied by LGE-CMR was specific and sensitive to predict VT CL and so could be a promising option to improve ICD post-implantation programming and decrease appropriate and inappropriate shocks. These conclusions must now be confirmed in a large and prospective study.


Asunto(s)
Cicatriz/etiología , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Imagen por Resonancia Magnética , Infarto del Miocardio/complicaciones , Miocardio/patología , Taquicardia Ventricular/terapia , Anciano , Área Bajo la Curva , Cicatriz/patología , Medios de Contraste , Femenino , Humanos , Masculino , Meglumina , Persona de Mediana Edad , Infarto del Miocardio/patología , Compuestos Organometálicos , Selección de Paciente , Valor Predictivo de las Pruebas , Curva ROC , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Resultado del Tratamiento
18.
Respir Med Res ; 84: 101025, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37734232

RESUMEN

BACKGROUND: Automated detection of sleep apnea (SA) by pacemaker (PM) has been proposed and exhibited good agreement with polysomnography to detect severe SA. We aimed to evaluate the usefulness of SA monitoring algorithm in elderly patients with diastolic dysfunction. METHODS: Consecutive patients referred to the Caen University Hospital for PM implantation between May 2016 and December 2018 presenting isolated diastolic dysfunction were eligible for the study. The respiratory disturbance index (RDI) measured by the PM, and the mean monthly RDI (RDIm), were compared to the apnea hypopnea index (AHI) assessed with portable monitor for severe SA diagnosis. RESULTS: During the study period, 68 patients were recruited, aged of 80.4 ± 8.2 years. 63 patients underwent polygraphy with a portable monitor: 57 presented SA (83.8%), including 16 with severe SA (23.5%). Eight were treated with continuous positive airway pressure (CPAP). We found the RDI cutoff value of 22 events/h to predict severe SA, with 71.4% sensitivity and 65.2%, specificity. The RDIm cutoff value to detect severe SA was 19 events/h, with a sensitivity of 60% and a specificity of 66%. There was a significant reduction in RDI (p = 0.041), RDIm (p = 0.039) and AHI (p = 0.002) after CPAP. Supraventricular arrhythmias were frequent in all patients, regardless of SA severity, considering either episodes occurrence or total burden. CONCLUSION: In a population of elderly patients with PM and diastolic dysfunction, the SA monitoring algorithm was able to detect severe SA, with good diagnostic performance values, but also to provide follow-up data for the patients treated with CPAP.


Asunto(s)
Marcapaso Artificial , Síndromes de la Apnea del Sueño , Anciano , Humanos , Sueño , Síndromes de la Apnea del Sueño/diagnóstico , Síndromes de la Apnea del Sueño/terapia , Polisomnografía , Algoritmos
19.
Arch Cardiovasc Dis ; 116(5): 265-271, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37179224

RESUMEN

BACKGROUND: Conduction system pacing (CSP) is an emerging and promising approach for physiological ventricular pacing. While data from randomized controlled trials are scarce, use of His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP) has increased in France. AIM: To perform a national snapshot survey for cardiac electrophysiologists to evaluate adoption of CSP in France. METHODS: An online survey, distributed to every senior cardiac electrophysiologist in France, was conducted in November 2022. RESULTS: A total of 120 electrophysiologists completed the survey. Eighty-three (69%) respondents reported experience in undertaking CSP procedures and 27 (23%) were planning to start performing CSP in the coming 2 years. The implantation techniques and criteria used for successful implantation differed significantly among operators. The most frequent indications for HBP and LBBAP were high-degree atrioventricular block with left ventricular ejection fraction (LVEF) < 40% (24 and 82%, respectively) or with LVEF ≥ 40% (27 and 74%, respectively), and after failure of a coronary sinus left ventricular lead (27 and 71%, respectively). The limitations respondents most frequently perceived when performing HBP were bad sensing/pacing parameters (45%), increased procedure duration (41%) and risk of lead dislodgement (30%). The most frequently perceived limitations to performing LBBAP were absence of guidelines or consensus (31%), lack of medical training (23%) and increased procedure duration (23%). CONCLUSIONS: Our national survey-based study supports wide adoption of CSP in France. CSP is currently used as a second-line approach for both antibradycardia and resynchronization indications, with important variations regarding implantation techniques and criteria for measuring success.


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiología , Humanos , Volumen Sistólico , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Electrocardiografía , Función Ventricular Izquierda , Terapia de Resincronización Cardíaca/efectos adversos , Resultado del Tratamiento
20.
Front Cardiovasc Med ; 10: 1169037, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37476572

RESUMEN

Background: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have the potential to act as a reliable predictor of the durability of the lesions created. Objective: We aimed to collect data on the procedural parameters affecting LI-guided ablation in a large multicenter registry. Methods: A total of 212 consecutive patients enrolled in the CHARISMA registry and undergoing their first pulmonary vein (PV) isolation for paroxysmal and persistent AF were included. Results: In all, 13,891 radiofrequency (RF) applications of ≥3 s duration were assessed. The first-pass PV isolation rate was 93.3%. A total of 80 PV gaps were detected. At successful ablation spots, baseline LI and absolute LI drop were larger than at PV gap spots (161.4 ± 19â€…Ω vs. 153.0 ± 13 Ω, p < 0.0001 for baseline LI; 22.1 ± 9â€…Ω vs. 14.4 ± 5 Ω, p < 0.0001 for LI drop). On the basis of Receiver operating characteristic curve analysis, the ideal LI drop, which predicted successful ablation, was >21â€…Ω at anterior sites and >18â€…Ω at posterior sites. There was a non-linear association between the magnitude of LI drop and contact-force (CF) (r = 0.14, 95% CI: 0.13-0.16, p < 0.0001) whereas both CF and LI drop were inversely related with delivery time (DT) (-0.22, -0.23 to -0.20, p < 0.0001 for CF; -0.27, -0.29 to -0.26, p < 0.0001 for LI drop). Conclusion: An LI drop >21â€…Ω at anterior sites and >18â€…Ω at posterior sites predicts successful ablation. A higher CF was associated with an increased likelihood of ideal LI drop. The combination of good CF and adequate LI drop allows a significant reduction in RF DT. Clinical trial registration: http://clinicaltrials.gov/, identifier: NCT03793998.

SELECCIÓN DE REFERENCIAS