Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 132
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Clin Infect Dis ; 2022 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-35767251

RESUMEN

BACKGROUND: Treatment success rates for multidrug-resistant tuberculosis (MDR-TB) remain low globally. Availability of newer drugs has given scope to develop regimens that can be patient-friendly, less toxic, with improved outcomes. We proposed to determine the effectiveness of an entirely oral, short-course regimen with Bedaquiline and Delamanid in treating MDR-TB with additional resistance to fluoroquinolones (MDR-TBFQ+) or second-line injectable (MDR-TBSLI+). METHODS: We prospectively determined the effectiveness and safety of combining two new drugs with two repurposed drugs - Bedaquiline, Delamanid, Linezolid, and Clofazimine for 24-36 weeks in adults with pulmonary MDR-TBFQ+ or/and MDR-TBSLI+. The primary outcome was a favorable response at end of treatment, defined as two consecutive negative cultures taken four weeks apart. The unfavorable outcomes included bacteriologic or clinical failure during treatment period. RESULTS: Of the 165 participants enrolled, 158 had MDR-TBFQ+. At the end of treatment, after excluding 12 patients due to baseline drug susceptibility and culture negatives, 139 of 153 patients (91%) had a favorable outcome. Fourteen patients (9%) had unfavorable outcomes: four deaths, seven treatment changes, two bacteriological failures, and one withdrawal. During treatment, 85 patients (52%) developed myelosuppression, 69 (42%) reported peripheral neuropathy, and none had QTc(F) prolongation >500msec. At 48 weeks of follow-up, 131 patients showed sustained treatment success with the resolution of adverse events in the majority. CONCLUSION: After 24-36 weeks of treatment, this regimen resulted in a satisfactory favorable outcome in pulmonary MDR-TB patients with additional drug resistance. Cardiotoxicity was minimal, and myelosuppression, while common, was detected early and treated successfully.

2.
Am Heart J ; 248: 1-12, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35219715

RESUMEN

BACKGROUND: Recurrence of atrial fibrillation (AF) after a pulmonary vein isolation procedure is often due to electrical reconnection of the pulmonary veins. Repeat ablation procedures may improve freedom from AF but are associated with increased risks and health care costs. A novel ablation strategy in which patients receive "augmented" ablation lesions has the potential to reduce the risk of AF recurrence. OBJECTIVE: The Augmented Wide Area Circumferential Catheter Ablation for Reduction of Atrial Fibrillation Recurrence (AWARE) Trial was designed to evaluate whether an augmented wide-area circumferential antral (WACA) ablation strategy will result in fewer atrial arrhythmia recurrences in patients with symptomatic paroxysmal AF, compared with a conventional WACA strategy. METHODS/DESIGN: The AWARE trial was a multicenter, prospective, randomized, open, blinded endpoint trial that has completed recruitment (ClinicalTrials.gov NCT02150902). Patients were randomly assigned (1:1) to either the control arm (single WACAlesion set) or the interventional arm (augmented- double WACA lesion set performed after the initial WACA). The primary outcome was atrial tachyarrhythmia (AA; atrial tachycardia [AT], atrial flutter [AFl] or AF) recurrence between days 91 and 365 post catheter ablation. Patient follow-up included 14-day continuous ambulatory ECG monitoring at 3, 6, and 12 months after catheter ablation. Three questionnaires were administered during the trial- the EuroQuol-5D (EQ-5D) quality of life scale, the Canadian Cardiovascular Society Severity of Atrial Fibrillation scale, and a patient satisfaction scale. DISCUSSION: The AWARE trial was designed to evaluate whether a novel approach to catheter ablation reduced the risk of AA recurrence in patients with symptomatic paroxysmal AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Canadá , Ablación por Catéter/métodos , Humanos , Estudios Prospectivos , Venas Pulmonares/cirugía , Calidad de Vida , Recurrencia , Resultado del Tratamiento
3.
Planta ; 256(2): 40, 2022 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-35834064

RESUMEN

MAIN CONCLUSION: This review highlights the economic importance of sweet potato and discusses new varieties, agronomic and cultivation practices, pest and disease control efforts, plant tissue culture protocols, and unexplored research areas involving this plant. Abstract Sweet potato is widely consumed in many countries around the world, including India, South Africa and China. Due to its valuable nutritional composition and highly beneficial bioactive compounds, sweet potato is considered a major tuber crop in India. Based on the volume of production, this plant ranks seventh in the world among all food crops. Sweet potato is considered a "Superfood" by the 'Centre for Science in the Public Interest' (CSPI), USA. This plant is mostly propagated through vegetative propagation using vine cuttings or tubers. However, this process is costly, labour-intensive, and comparatively slow. Conventional propagation methods are not able to supply sufficient disease-free planting materials to farmers to sustain steady tuber production. Therefore, there is an urgent need to use various biotechnological approaches, such as cell, tissue, and organ culture, for the large-scale production of healthy and disease-free planting material for commercial purposes throughout the year. In the last five decades, a number of tissue culture protocols have been developed for the production of in vitro plants through meristem culture, direct adventitious organogenesis, callus culture and somatic embryogenesis. Moreover, little research has been done on synthetic seed technology for the in vitro conservation and propagation of sweet potato. The current review comprehensively describes the biology, i.e., plant phenotypic description, vegetative growth, agronomy and cultivation, pests and diseases, varieties, and conventional methods of propagation, as well as biotechnological implementation, of this tuber crop. Furthermore, the explored and unexplored areas of research in sweet potato using biotechnological approaches have been reviewed.


Asunto(s)
Ipomoea batatas , Biología , Biotecnología , Productos Agrícolas , Tubérculos de la Planta
4.
J Cardiovasc Electrophysiol ; 32(2): 212-223, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33179399

RESUMEN

INTRODUCTION: Defining atrial fibrillation (AF) wave propagation is challenging unless local signal features are discrete or periodic. Periodic focal or rotational activity may identify AF drivers. Our objective was to characterize AF propagation at sites with periodic activation to evaluate the prevalence and relationship between focal and rotational activation. METHODS: We included 80 patients (61 ± 10 years, persistent AF 49%) from the FaST randomized trial that compared the efficacy of adjunctive focal site ablation versus pulmonary vein isolation. Patients underwent left atrial (LA) activation mapping with a 20-pole circular catheter during spontaneous or induced AF. Five-second bipolar and unipolar electrograms in AF were analyzed. Periodic sites were identified by spectral analysis of the bipolar electrogram. Activation maps of periodic sites were constructed using an automated, validated tracking algorithm, and classified into three patterns: focal sites (FS), rotation (RO), or pseudo-rotation (pRO). RESULTS: The most common propagation pattern at periodic sites was FS for 5-s in all patients (4.9 ± 1.9 per patient). RO and pRO were observed in two and seven patients, respectively, but were all transient (3-5 cycles). Activation from a FS evolved into transient RO/pRO in five patients. No patient had autonomous RO/pRO activations. Patients with RO/pRO had greater LA surface area with periodicity (78 ± 7 vs. 63 ± 16%, p = .0002) and shorter LA periodicity CL (166 ± 10 vs. 190±28 ms, p = .0001) than the rest. CONCLUSION: Using automated, regional AF periodicity mapping, FS is more prevalent and temporally stable than RO/pRO. Most RO/pRO evolve from neighboring FS. These findings and their implications for AF maintenance require verification with global, panoramic mapping.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/cirugía , Humanos , Persona de Mediana Edad , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía
5.
J Cardiovasc Electrophysiol ; 32(6): 1572-1583, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33694221

RESUMEN

INTRODUCTION: An important substrate for atrial fibrillation (AF) is fibrotic atrial myopathy. Identifying low voltage, myopathic regions during AF using traditional bipolar voltage mapping is limited by the directional dependency of wave propagation. Our objective was to evaluate directionally independent unipolar voltage mapping, but with far-field cancellation, to identify low-voltage regions during AF. METHODS: In 12 patients undergoing pulmonary vein isolation for AF, high-resolution voltage mapping was performed in the left atrium during sinus rhythm and AF using a roving 20-pole circular catheter. Bipolar electrograms (EGMs) (Bi) < 0.5 mV in sinus rhythm identified low-voltage regions. During AF, bipolar voltage and unipolar voltage maps were created, the latter with (uni-res) and without (uni-orig) far-field cancellation using a novel, validated least-squares algorithm. RESULTS: Uni-res voltage was ~25% lower than uni-orig for both low voltage and normal atrial regions. Far-field EGM had a dominant frequency (DF) of 4.5-6.0 Hz, and its removal resulted in a lower DF for uni-orig compared with uni-res (5.1 ± 1.5 vs. 4.8 ± 1.5 Hz; p < .001). Compared with Bi, uni-res had a significantly greater area under the receiver operator curve (0.80 vs. 0.77; p < .05), specificity (86% vs. 76%; p < .001), and positive predictive value (43% vs. 30%; p < .001) for detecting low-voltage during AF. Similar improvements in specificity and positive predictive value were evident for uni-res versus uni-orig. CONCLUSION: Far-field EGM can be reliably removed from uni-orig using our novel, least-squares algorithm. Compared with Bi and uni-orig, uni-res is more accurate in detecting low-voltage regions during AF. This approach may improve substrate mapping and ablation during AF, and merits further study.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos , Venas Pulmonares/cirugía
6.
BMC Health Serv Res ; 21(1): 435, 2021 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-33957918

RESUMEN

BACKGROUND/PURPOSE: Interventional cardiac electrophysiology (EP) is a rapidly evolving field in Canada; a nationwide registry was established in 2011 to conduct a periodic review of resource allocation. METHODS: The registry collects annual data on EP lab infrastructure, imaging, tools, human resources, procedural volumes, success rates, and wait times. Leading physicians from each EP lab were contacted electronically; participation was voluntary. RESULTS: All Canadian EP centres were identified (n = 30); 50 and 45 % of active centres participated in the last 2 instalments of the registry. A mean of 508 ± 270 standard and complex catheter ablation procedures were reported annually for 2015-2016 by all responding centres. The most frequently performed ablation targets atrial fibrillation (PVI) arrhythmia accounting for 36 % of all procedures (mean = 164 ± 85). The number of full time physicians ranges between 1 and 7 per centre, (mean = 4). The mean wait time to see an electrophysiologist for an initial non-urgent consult is 23 weeks. The wait time between an EP consult and ablation date is 17.8 weeks for simple ablation, and 30.1 weeks for AF ablation. On average centres have 2 (range: 1-4) rooms equipped for ablations; each centre uses the EP lab an average of 7 shifts per week. While diagnostic studies and radiofrequency ablations are performed in all centres, point-by-point cryoablation is available in 85 % centres; 38 % of the respondents use circular ablation techniques. CONCLUSIONS: This initiative provides contemporary data on invasive electrophysiology lab practices. The EP registry provides activity benchmarks on national trends and practices.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/cirugía , Canadá/epidemiología , Técnicas Electrofisiológicas Cardíacas , Electrofisiología , Humanos , Sistema de Registros , Resultado del Tratamiento
7.
Pacing Clin Electrophysiol ; 42(2): 189-200, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30515873

RESUMEN

BACKGROUND: QRS abnormalities may not be apparent in sinus rhythm in electrically stable cardiomyopathy patients who can have quiescent but highly arrhythmogenic substrate. Here, we test the hypothesis that differential changes in QRS construction during right-ventricular apex pacing (RVP) as opposed to atrial pacing (AP) will identify latent substrate for ventricular arrhythmias (VA) and death. METHODS: Forty patients with cardiomyopathy free of VA underwent baseline 114-electrode body-surface electrocardiogram during AP (100 beats per minute [bpm]) and RVP (100 and 120 bpm). The filtered-averaged QRS at each electrode was deconstructed into individual intra-QRS and post-QRS ventricular myopotentials (VMP ). The primary outcome was VA or death. Prognostic accuracy of VMP was validated using V1 to V6 leads in another prospective cohort of 44-cardiomyopathy patients. RESULTS: Twenty-six patients were eligible for initial analysis. After 5 ± 2 years of follow-up, eight (31%) patients had VA (VAPos ) while rest were uneventful (VANeg ). During AP100 , VAPos patients expressed more VMP than VANeg patients (16 ± 1 vs 12 ± 1, P = 0.02). RVP100 and RVP120 in VAPos patients introduced an additional 5.5 ± 0.5 and 6.0 ± 0.5 VMP (P < 0.0001 vs AP100 ). The relative change with RVP120 versus AP100 in VANeg patients exceeded VAPos patients by 1.2 ± 0.5 VMP (P = 0.03). Increment in VMP count of <8 in lead-V5 with RVP120 compared to AP100 best predicted VA (area under curve 0.81, P = 0.01). In the validation cohort, primary outcome occurred in 13 (33%) patients. Native QRS features and AP100 alone failed to predict primary outcome. Patients with increment in VMP count of <8 in lead-V5 with RVP120 versus AP100 had 7.9-fold increased risk of primary outcome (95% confidence interval 1.01, 61.61; P = 0.049). CONCLUSION: Cardiomyopathy patients at risk of VA or death perturb the QRS less than low-risk patients with differential pacing. This functional response may be useful to identify arrhythmogenic substrate.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Electrocardiografía , Anciano , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Cardiomiopatías/complicaciones , Cardiomiopatías/fisiopatología , Electrocardiografía/métodos , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Medición de Riesgo
9.
J Electrocardiol ; 51(4): 720-722, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29997020

RESUMEN

In patients with suspected ST elevation myocardial infarction, it is of paramount importance to identify artifacts on the resting electrocardiogram that may be erroneously interpreted as ST segment deviations in order to prevent administration of potentially harmful pharmacotherapy and invasive coronary angiography. In this case report, we describe a pervasive square wave artifact, not previously reported, that was misdiagnosed as ST segment elevation by computer software and initial physician interpretation.


Asunto(s)
Artefactos , Errores Diagnósticos , Electrocardiografía , Infarto del Miocardio con Elevación del ST/diagnóstico , Anciano , Dolor en el Pecho/etiología , Angiografía Coronaria , Diagnóstico por Computador , Humanos , Cirrosis Hepática Alcohólica/complicaciones , Masculino , Enfermedad Pulmonar Obstructiva Crónica/complicaciones
10.
Pacing Clin Electrophysiol ; 40(4): 417-424, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28155223

RESUMEN

BACKGROUND: In about 20-25% of patients with congenital long QT syndrome (LQTS) a causative pathogenic mutation is not found. The aim of this study was to explore the prevalence of alternative cardiac diagnoses among patients exhibiting prolongation of QT interval with negative genetic testing for LQTS genes. METHODS: We conducted a retrospective analysis of 239 consecutive patients who were evaluated in the inherited arrhythmia clinic at the Toronto General Hospital between July 2013 and December 2015 for possible LQTS. A detailed review of the patients' charts, electrocardiograms, and imaging was carried out. RESULTS: The analysis included 56 gene-negative patients and 61 gene-positive patients. Of the gene-negative group, 25% had structural heart disease compared to only 1.6% of gene-positive patients (P < 0.001). Structural heart disease was more likely if only one abnormal QTc parameter was found in the course of the evaluation (35.2% vs 9.1%, P = 0.01). The most common structural cardiac pathology was bileaflet mitral valve prolapse (8.9%). No gene-positive patient had episodes of nonsustained ventricular tachycardia, compared to seven of the gene-negative patients (0% vs 12.5%, P = 0.005). CONCLUSIONS: Structural pathology was detected in a quarter of gene-negative patients evaluated for possible LQTS. Hence, cardiac imaging and Holter monitoring should be strongly encouraged to rule out structural heart disease in this population.


Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Cardiomiopatías/diagnóstico , Electrocardiografía/métodos , Síndrome de QT Prolongado/diagnóstico por imagen , Síndrome de QT Prolongado/genética , Adulto , Cardiomiopatías/genética , Diagnóstico Diferencial , Femenino , Predisposición Genética a la Enfermedad/genética , Pruebas Genéticas , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
11.
Curr Cardiol Rep ; 19(9): 88, 2017 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-28812208

RESUMEN

PURPOSE OF REVIEW: Genetic testing has become an important element in the care of patients with inherited cardiac conditions (ICCs). The purpose of this review is to provide clinicians with insights into the utility of genetic testing as well as challenges associated with interpreting results. RECENT FINDINGS: Genetic testing may be indicated for individuals who are affected with or who have family histories of various ICCs. Various testing options are available and determining the most appropriate test for any given clinical scenario is key when interpreting results. Newly published guidelines as well as various publicly accessible tools are available to clinicians to help with interpretation of genetic findings; however the subjectivity with respect to variant classification can make accurate assessment challenging. Genetic information can provide highly useful and relevant information for patients, their family members, and their healthcare providers. Given the potential ramifications of variant misclassification, expertise in both clinical phenotyping and molecular genetics is imperative in order to provide accurate diagnosis, management recommendations, and family risk assessment for this patient population.


Asunto(s)
Pruebas Genéticas/métodos , Cardiopatías/diagnóstico , Cardiopatías/genética , Humanos , Guías de Práctica Clínica como Asunto , Medición de Riesgo
12.
Pacing Clin Electrophysiol ; 39(7): 642-51, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27027856

RESUMEN

BACKGROUND: Nonsustained ventricular tachycardia (NSVT) detected by ambulatory Holter (Holter NSVT) is a major risk factor for sudden cardiac death in hypertrophic cardiomyopathy (HCM). We hypothesized that the prognostic utility of Holter NSVT in HCM would improve with prolonged monitoring and a higher heart rate cut-off for detection. METHODS: We enrolled 60 patients (44 ± 14 years) with HCM, who had a prophylactic implantable cardioverter defibrillator (ICD). Positive Holter NSVT (prior to implant) was defined as ≥3 beats at ≥120 beats per minute (bpm). We assessed the prevalence of rapid NSVT (RNSVT) detected by their ICD within 12 months of its implant, defined as 4-16 beats at ≥150-200 bpm. The primary outcome was appropriate ICD therapy (antitachycardia pacing and shocks) for sustained ventricular arrhythmia (VA). RESULTS: Holter NSVT was detected in 34 patients. RNSVT occurred in 21 (35%) patients of whom five did not have Holter NSVT. Over a median follow-up of 61 (interquartile range 29, 129) months after ICD implant, nine patients had VA. RNSVT, but not Holter NSVT, was significantly associated with VA (hazard ratio 6.2, 95% confidence interval [1.3-30], P = 0.01) by multivariable Cox regression analysis that included conventional risk factors. Receiver operating characteristic analysis for RNSVT (area under curve 0.80, P = 0.005) showed that the occurrence of ≥2 episodes of RNSVT discriminated patients for VA optimally (sensitivity 78%, specificity 84%, positive predictive value 47%, negative predictive value 96%). CONCLUSIONS: In this pilot study, RNSVT detected by continuous monitoring independently predicted VA in HCM and offered superior discrimination of VA risk compared to conventional risk factors, including Holter NSVT. Future studies are needed to validate these findings in a larger, unselected HCM cohort.


Asunto(s)
Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico , Diagnóstico por Computador/métodos , Electrocardiografía Ambulatoria/métodos , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Reproducibilidad de los Resultados , Medición de Riesgo/métodos , Sensibilidad y Especificidad , Adulto Joven
13.
Indian Pacing Electrophysiol J ; 15(3): 168-71, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26937112

RESUMEN

The right atrial appendage can be the origin of focal atrial tachycardias. Their ablation can be challenging owing to the complexity of the appendage anatomy. To our knowledge, we describe the first successful solid tip cryoablation of a focal tachycardia within the right atrial appendage in a patient presenting with tachycardia-induced cardiomyopathy.

14.
Europace ; 16(11): 1684-8, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24554525

RESUMEN

AIMS: Current conventional ablation strategies for ventricular tachycardia (VT) aim to interrupt reentrant circuits by creating ablation lesions. However, the critical components of reentrant VT circuits may be located at deep intramural sites. We hypothesized that bipolar ablations would create deeper lesions than unipolar ablation in human hearts. METHODS AND RESULTS: Ablation was performed on nine explanted human hearts at the time of transplantation. Following explant, the hearts were perfused by using a Langendorff perfusion setup. For bipolar ablation, the endocardial catheter was connected to the generator as the active electrode and the epicardial catheter as the return electrode. Unipolar ablation was performed at 50 W with irrigation of 25 mL/min, with temperature limit of 50°C. Bipolar ablation was performed with the same settings. Subsequently, in a patient with an incessant septal VT, catheters were positioned on the septum from both the ventricles and radiofrequency was delivered with 40 W. In the explanted hearts, there were a total of nine unipolar ablations and four bipolar ablations. The lesion depth was greater with bipolar ablation, 14.8 vs. 6.1 mm (P < 0.01), but the width was not different (9.8 vs. 7.8 mm). All bipolar lesions achieved transmurality in contrast to the unipolar ablations. In the patient with a septal focus, bipolar ablation resulted in termination of VT with no inducible VTs. CONCLUSION: By using a bipolar ablation technique, we have demonstrated the creation of significantly deeper lesions without increasing the lesion width, compared with standard ablation. Further clinical trials are warranted to detail the risks of this technique.


Asunto(s)
Ablación por Catéter/métodos , Sistema de Conducción Cardíaco/cirugía , Taquicardia Ventricular/cirugía , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Técnicas In Vitro , Masculino , Persona de Mediana Edad , Perfusión , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Irrigación Terapéutica , Resultado del Tratamiento
15.
Homeopathy ; 103(4): 224-31, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25439038

RESUMEN

INTRODUCTION: The decision to treat subclinical hypothyroidism (SCH) with or without autoimmune thyroiditis (AIT) in children, presents a clinical dilemma. This study was undertaken to evaluate the efficacy of individualized homeopathy in these cases. METHODS: The study is an exploratory, randomized, placebo controlled, single blind trial. Out of 5059 school children (06-18 years) screened for thyroid disorders, 537 children had SCH/AIT and 194 consented to participate. Based on primary outcome measures (TSH and/or antiTPOab) three major groups were formed: Group A - SCH + AIT (n = 38; high TSH with antiTPOab+), Group B - AIT (n = 47; normal TSH with antiTPOab+) and Group C - SCH (n = 109; only high TSH) and were further randomized to two subgroups-verum and control. Individualized homeopathy or identical placebo was given to respective subgroup. 162 patients completed 18 months of study. RESULTS: Baseline characteristics were similar in all the subgroups. The post treatment serum TSH (Group A and C) returned to normal limits in 85.94% of verum and 64.29% of controls (p < 0.006), while serum AntiTPOab titers (Group A and B) returned within normal limits in 70.27%of verum and 27.02%controls (p < 0.05). Eight children (10.5%) progressed to overt hypothyroidism (OH) from control group. CONCLUSION: A statistically significant decline in serum TSH values and antiTPOab titers indicates that the homeopathic intervention has not only the potential to treat SCH with or without antiTPOab but may also prevent progression to OH.


Asunto(s)
Homeopatía , Hipotiroidismo/complicaciones , Isoanticuerpos/uso terapéutico , Tiroiditis Autoinmune/tratamiento farmacológico , Tirotropina/sangre , Adolescente , Niño , Femenino , Humanos , India , Masculino , Método Simple Ciego , Tiroiditis Autoinmune/complicaciones , Resultado del Tratamiento
16.
Artículo en Inglés | MEDLINE | ID: mdl-38934974

RESUMEN

BACKGROUND: Abnormal ventricular activation at rest is reported in Brugada syndrome (BrS). OBJECTIVES: The aim of this study was to evaluate the usefulness of dynamic changes in ventricular activation during exercise to improve disease phenotyping and diagnosis of BrS. METHODS: Digital 12-lead electrocardiograms during stress testing were analyzed retrospectively at baseline, peak exercise, and recovery in 53 patients with BrS and 52 controls. Biventricular activation was assessed from QRS duration (QRSd), whereas right ventricular activation was assessed from S wave duration in the lateral leads (I and V6) and terminal R wave duration in aVR. Exercise-induced changes in QRS parameters to predict a positive procainamide response were assessed in separate test and validation cohorts with suspected BrS. RESULTS: Baseline electrocardiogram parameters were similar between BrS and controls. QRSd shortened with exercise in all controls but prolonged in all BrS (-6.1 ± 6.0 ms vs 7.1 ± 6.5 ms [P < 0.001] in V6). QRSd in recovery was longer in BrS compared with controls (90 ± 12 ms vs 82 ± 11 ms in V6; P = 0.002). Both groups demonstrated exercise-induced S duration prolongation in V6, with greater prolongation in BrS (8.2 ± 14.3 ms vs 1.2 ± 12.4 ms; P < 0.001). Any exercise-induced QRSd prolongation in V6 differentiated those with a positive vs negative procainamide response with 100% sensitivity and 95% specificity in the test cohort, and 87% sensitivity and 93% specificity in the validation cohort. CONCLUSIONS: Exercise-induced QRSd prolongation is ubiquitous in BrS primarily owing to delayed right ventricular activation. This electrocardiogram phenotype predicts a positive procainamide response and may provide a noninvasive screening tool to aid in the diagnosis of BrS before drug challenge.

17.
J Cardiovasc Electrophysiol ; 24(6): 708-10, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23217083

RESUMEN

Scar delineation with late gadolinium-enhanced MRI can direct VT substrate mapping and ablation, but imaging is poor and relatively contraindicated in the majority of patients with ICDs. We present a case of scar definition using late iodine-enhanced multidetector CT in a patient with ischemic cardiomyopathy and multiple ICD shocks for VT. CT images were acquired using a novel intracoronary contrast delivery protocol which provided high-resolution subendocardial scar visualization. The segmented scar images were subsequently imported into an electroanatomic mapping platform to guide successful VT ablation.


Asunto(s)
Ablación por Catéter , Tomografía Computarizada Multidetector/métodos , Miocardio/patología , Taquicardia Ventricular/patología , Taquicardia Ventricular/cirugía , Anciano , Cicatriz/patología , Humanos , Yodo , Masculino
18.
Circ Res ; 109(11): 1309-18, 2011 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-21980123

RESUMEN

RATIONALE: Ventricular fibrillation (VF) leads to global ischemia. The modulation of ischemia-dependent pathways may alter the electrophysiological evolution of VF. OBJECTIVE: We addressed the hypotheses that there is regional disease-related expression of K(ATP) channels in human cardiomyopathic hearts and that K(ATP) channel blockade promotes spontaneous VF termination by attenuating spatiotemporal dispersion of refractoriness. METHODS AND RESULTS: In a human Langendorff model, electric mapping of 6 control and 9 treatment (10 µmol/L glibenclamide) isolated cardiomyopathic hearts was performed. Spontaneous defibrillation was studied and mean VF cycle length was compared regionally at VF onset and after 180 seconds between control and treatment groups. K(ATP) subunit gene expression was compared between LV endocardium versus epicardium in myopathic hearts. Spontaneous VF termination occurred in 1 of 6 control hearts and 7 of 8 glibenclamide-treated hearts (P=0.026). After 180 seconds of ischemia, a transmural dispersion in VF cycle length was observed between epicardium and endocardium (P=0.001), which was attenuated by glibenclamide. There was greater gene expression of all K(ATP) subunit on the endocardium compared with the epicardium (P<0.02). In an ischemic rat heart model, transmural dispersion of refractoriness (ΔERP(Transmural)=ERP(Epicardium)-ERP(Endocardium)) was verified with pacing protocols. ΔERP(Transmural) in control was 5 ± 2 ms and increased to 36 ± 5 ms with ischemia. This effect was greatly attenuated by glibenclamide (ΔERP(Transmural) for glibenclamide+ischemia=4.9 ± 4 ms, P=0.019 versus control ischemia). CONCLUSIONS: K(ATP) channel subunit gene expression is heterogeneously altered in the cardiomyopathic human heart. Blockade of K(ATP) channels promotes spontaneous defibrillation in cardiomyopathic human hearts by attenuating the ischemia-dependent spatiotemporal heterogeneity of refractoriness during early VF.


Asunto(s)
Cardiomiopatía Dilatada/complicaciones , Canales KATP/fisiología , Fibrilación Ventricular/fisiopatología , Potenciales de Acción/efectos de los fármacos , Animales , Endocardio/metabolismo , Gliburida/farmacología , Humanos , Técnicas In Vitro , Lidocaína/farmacología , Masculino , Isquemia Miocárdica/etiología , Marcapaso Artificial , Perfusión , Pericardio/metabolismo , ARN Mensajero/biosíntesis , Ratas , Ratas Sprague-Dawley , Periodo Refractario Electrofisiológico/efectos de los fármacos , Fibrilación Ventricular/etiología
19.
Can J Cardiol ; 39(10): 1421-1431, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37100282

RESUMEN

BACKGROUND: Atrial low-voltage areas (LVAs) in patients with atrial fibrillation increase the risk of atrial arrhythmia (AA) recurrence after pulmonary vein isolation (PVI). Contemporary LVA prediction scores (DR-FLASH, APPLE) do not include P-wave metrics. We aimed to evaluate the utility of P-wave duration/amplitude ratio (PWR) in quantifying LVA and predicting AA recurrence after PVI. METHODS: In 65 patients undergoing first-time PVI, 12-lead ECGs were recorded during sinus rhythm. PWR was calculated as the ratio between the longest P-wave duration and P-wave amplitude in lead I. High-resolution biatrial voltage maps were collected and LVAs included bipolar electrogram amplitudes < 0.5 mV or < 1.0 mV. An LVA quantification model was created with the use of clinical variables and PWR, and then validated in a separate cohort of 24 patients. Seventy-eight patients were followed for 12 months to evaluate AA recurrence. RESULTS: PWR strongly correlated with left atrial (LA) (< 0.5 mV: r = 0.60; < 1.0 mV: r = 0.68; P < 0.001) and biatrial LVA (< 0.5 mV: r = 0.63; < 1.0 mV: r = 0.70; P < 0.001). Addition of PWR to clinical variables improved model quantification of LA LVA at the < 0.5 mV (adjusted R2 = 0.59 to 0.68) and < 1.0 mV (adjusted R2 = 0.59 to 0.74) cutoffs. In the validation cohort, PWR model-predicted LVA correlated strongly with measured LVA (< 0.5 mV: r = 0.78; < 1.0 mV: r = 0.81; P < 0.001). PWR model was superior to DR-FLASH (area under the receiver operating characteristic curve [AUC] 0.90 vs 0.78; P = 0.030) and APPLE (AUC 0.90 vs 0.67; P = 0.003) at detecting LA LVA and similar at predicting AA recurrence after PVI (AUC 0.67 vs 0.65 and 0.60). CONCLUSION: Our novel PWR model accurately quantifies LVA and predicts AA recurrence after PVI. PWR model-predicted LVA may help guide patient selection for PVI.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Atrios Cardíacos , Electrocardiografía , Curva ROC , Recurrencia , Resultado del Tratamiento
20.
JAMA Cardiol ; 8(5): 475-483, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36947030

RESUMEN

Importance: Recurrent atrial fibrillation (AF) commonly occurs after catheter ablation and is associated with patient morbidity and health care costs. Objective: To evaluate the superiority of an augmented double wide-area circumferential ablation (WACA) compared with a standard single WACA in preventing recurrent atrial arrhythmias (AA) (atrial tachycardia, atrial flutter, or atrial fibrillation [AF]) in patients with paroxysmal AF. Design, Setting, and Participants: This was a pragmatic, multicenter, prospective, randomized, open, blinded end point superiority clinical trial conducted at 10 university-affiliated centers in Canada. The trial enrolled patients 18 years and older with symptomatic paroxysmal AF from March 2015 to May 2017. Analysis took place between January and April 2022. Analyses were intention to treat. Interventions: Patients were randomized (1:1) to receive radiofrequency catheter ablation for pulmonary vein isolation with either a standard single WACA or an augmented double WACA. Main Outcomes and Measures: The primary outcome was AA recurrence between 91 and 365 days postablation. Patients underwent 42 days of ambulatory electrocardiography monitoring after ablation. Secondary outcomes included need for repeated catheter ablation and procedural and safety variables. Results: Of 398 patients, 195 were randomized to the single WACA (control) arm (mean [SD] age, 60.6 [9.3] years; 65 [33.3%] female) and 203 to the double WACA (experimental) arm (mean [SD] age, 61.5 [9.3] years; 66 [32.5%] female). Overall, 52 patients (26.7%) in the single WACA arm and 50 patients (24.6%) in the double WACA arm had recurrent AA at 1 year (relative risk, 0.92; 95% CI, 0.66-1.29; P = .64). Twenty patients (10.3%) in the single WACA arm and 15 patients (7.4%) in the double WACA arm underwent repeated catheter ablation (relative risk, 0.72; 95% CI, 0.38-1.36). Adjudicated serious adverse events occurred in 13 patients (6.7%) in the single WACA arm and 14 patients (6.9%) in the double WACA arm. Conclusions and Relevance: In this randomized clinical trial of patients with paroxysmal AF, additional ablation by performing a double ablation lesion set did not result in improved freedom from recurrent AA compared with a standard single ablation set. Trial Registration: ClinicalTrials.gov Identifier: NCT02150902.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Femenino , Persona de Mediana Edad , Masculino , Fibrilación Atrial/tratamiento farmacológico , Estudios Prospectivos , Venas Pulmonares/cirugía , Electrocardiografía Ambulatoria , Ablación por Catéter/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA