Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Magn Reson Med ; 92(3): 1011-1021, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38623991

RESUMEN

PURPOSE: Demonstrate the potential of spatiotemporal encoding (SPEN) MRI to deliver largely undistorted 2D, 3D, and diffusion weighted images on a 110 mT portable system. METHODS: SPEN's quadratic phase modulation was used to subsample the low-bandwidth dimension of echo planar acquisitions, delivering alias-free images with an enhanced immunity to image distortions in a laboratory-built, low-field, portable MRI system lacking multiple receivers. RESULTS: Healthy brain images with different SPEN time-bandwidth products and subsampling factors were collected. These compared favorably to EPI acquisitions including topup corrections. Robust 3D and diffusion weighted SPEN images of diagnostic value were demonstrated, with 2.5 mm isotropic resolutions achieved in 3 min scans. This performance took advantage of the low specific absorption rate and relative long TEs associated with low-field MRI. CONCLUSION: SPEN MRI provides a robust and advantageous fast acquisition approach to obtain faithful 3D images and DWI data in low-cost, portable, low-field systems without parallel acceleration.


Asunto(s)
Encéfalo , Imagenología Tridimensional , Imagen por Resonancia Magnética , Humanos , Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Diseño de Equipo , Reproducibilidad de los Resultados , Algoritmos , Aumento de la Imagen/métodos , Sensibilidad y Especificidad , Análisis Espacio-Temporal , Procesamiento de Señales Asistido por Computador , Imagen Eco-Planar , Análisis de Falla de Equipo , Interpretación de Imagen Asistida por Computador/métodos , Imagen de Difusión por Resonancia Magnética
2.
NMR Biomed ; 36(5): e4875, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36357354

RESUMEN

Earlier diagnosis of nonalcoholic fatty liver disease (NAFLD) is important to prevent progression of the disease. Recently, a low-cost portable magnetic resonance (MR) system was developed as a point-of-care screening tool for in vivo liver fat quantification. However, subcutaneous fat may confound the liver fat quantification, particularly in the NAFLD population. In this work, we propose a novel radiofrequency (RF) coil design composed of a set of "saturation" coils sandwiching a main coil to improve human liver fat quantification. By comparison with conventional MR imaging, we demonstrate the capability and effectiveness of the novel RF coil design in phantom experiments as well as in vivo liver scans. In the phantom experiment, the saturation coil reduced the error in the measured proton density fat fraction (PDFF) results from 28.9% to 4.0%, and in the in vivo experiment, it reduced the discrepancy in the PDFF results from 13.2% to 4.0%. The novel coil design, together with the adapted Carr-Purcell-Meiboom-Gill-based sequence, improves the practicability and robustness of the portable single-side MR system.


Asunto(s)
Enfermedad del Hígado Graso no Alcohólico , Humanos , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Hígado/diagnóstico por imagen , Hígado/patología , Espectroscopía de Resonancia Magnética , Imagen por Resonancia Magnética/métodos , Tejido Adiposo/diagnóstico por imagen , Tejido Adiposo/patología , Protones
3.
Forensic Sci Int ; 282: 35-40, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29149685

RESUMEN

According to domestic and international epidemiological investigation, the proportion of substance involved sexual assault has the trend of ascent. In the past, laboratory methods that investigated urine sample of the sexual assault victims was to screen with enzyme immunoassay and then confirmed with mass spectrometry. The objective of the study is to simultaneously identify abused drugs in 126 decoded urine samples of sexual assault victims by liquid chromatography tandem mass spectrometry. The instrument was operated in multiple-reaction monitoring with an electro-spray positive ionization mode. Chromatograms were separated with ACE5 C18 column on a gradient of acetonitrile. After liquid-liquid extraction, samples were passed through a 0.22µm PVDF filter before injection into the system. The limits of quantitation ranged from 0.2 to 10ng/mL. The precision (CV) results were below 12.9% (intraday) and 15.0% (interday). The intraday accuracy ranged from 84.8 to 121.0%, interday accuracy ranged from 72.0 to 117.3%. We found that 29 (23.0%) were positive for drugs. The most common drug identified is flunitrazepam (11.1%), followed by nimetazepam and ketamine (7.9%), some new psychoactive substances, such as 2C-B, mephedrone, methylone, PMA and PMMA were also identified. We identified abused drugs, benzodiazepines, and new psychoactive substances in urine of sexual assault victims by using liquid chromatography tandem mass spectrometry.


Asunto(s)
Víctimas de Crimen , Narcóticos/orina , Psicotrópicos/orina , Violación , Detección de Abuso de Sustancias/métodos , Benzodiazepinas/orina , Cromatografía Liquida , Toxicología Forense/métodos , Humanos , Espectrometría de Masas en Tándem
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA