Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Opt Express ; 32(8): 14133-14142, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38859367

RESUMEN

Compact efficient high-power continuous-wave Nd:YVO4 Raman lasers for selectable wavelengths within 559-603 nm are achieved by using KGW crystal for intracavity stimulated Raman scattering (SRS) and lithium triborate (LBO) crystal for intracavity sum frequency generation (SFG) and second harmonic generation (SHG). The LBO crystal with the cut angle in the XY plane for the type-I phase matching is used to perform intracavity SHG or SFG. Experimental results reveal that the participated Stokes lines include the internal vibration mode at 901 cm-1, the external vibrational mode at 209 cm-1, and the combination mode of the 901 cm-1 and 209 cm-1 Raman shifts. By tuning LBO temperature for attaining the maximum output power, the output spectrum reveals the triple peaks of 588.7, 595.7, and 603.1 nm with the intensity ratio of 10:4:1. Under this circumstance, the output power can reach the highest value of 10.8 W at a pump power of 40 W. Furthermore, the output spectrum can be simply concentrated on the single peaks among 588.7 (orange), 565.7 (yellow), and 559.1 nm (lime) by tuning LBO temperature to fulfill the selection of the critical phase matching. The output powers at a pump power of 40 W can be up to 8.0, 6.1, and 9.8 W for the single-peak emission at 588.7, 565.7, and 559.1 nm, respectively. Finally, a dual-peak emission of 565.7 and 572.3 nm with total output power of 5.2 W can be generated by tuning LBO temperature to match the SFG for 572.3 nm.

2.
Opt Express ; 32(8): 14461-14470, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38859390

RESUMEN

High-power efficient continuous-wave Nd:YVO4/KGW Raman lasers at 555 and 559 nm are achieved by using a double-sided dichroic coating output coupler to improve the resonance quality factor. The Np-cut potassium gadolinium tungstate (KGW) is used to generate the Stokes waves at 1159 and 1177 nm by placing the polarization of the1064 nm fundamental wave parallel to the Ng and Nm axes, respectively. The lithium triborate (LBO) crystal with the cut angle in the XY plane for the type-I phase matching is used to perform the intracavity sum frequency generation for yielding the green light at 555 nm and the lime light at 559 nm at the optimal phase matching temperature. Experimental results were systematically accomplished to comprehend the optimal cavity length for the conversion efficiency. Under the optimal cavity length, the output powers can reach 6.6 and 6.3 W at a pump power of 22 W for the wavelengths of 555 and 559 nm, respectively. The conversion efficiencies can be up to 30% and 28.6% for 555 and 559 nm, respectively.

3.
Opt Express ; 31(5): 8696-8703, 2023 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-36859979

RESUMEN

Efficient diode-pumped passively Q-switched Nd:YVO4 yellow and orange lasers are developed with the pulse pumping scheme and the intracavity stimulated Raman scattering (SRS) and second harmonic generation (SHG). A Np-cut KGW is exploited in the SRS process to generate the yellow 579 nm laser or the orange 589 nm laser in a selectable way. The high efficiency is achieved by designing a compact resonator to include a coupled cavity for intracavity SRS and SHG and to provide a focused beam waist on the saturable absorber for reaching an excellent passive Q-switching. The output pulse energy and peak power can reach 0.08 mJ and 50 kW for the orange laser at 589 nm. On the other hand, the output pulse energy and peak power can be up to 0.10 mJ and 80 kW for the yellow laser at 579 nm.

4.
Opt Lett ; 48(17): 4645-4648, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37656576

RESUMEN

Two compact laser sources at 707 and 714 nm are realized efficiently by using a diode-pumped a-cut Nd:YVO4 laser with intracavity stimulated Raman scattering and sum-frequency generation (SFG). The fundamental wave at 1342 nm is generated by the 4F3/2 → 4I13/2 transition in Nd:YVO4 crystal. The Raman Stokes waves at 1496 and 1526 nm were obtained by placing the c-axis of the Nd:YVO4 crystal along the Ng and Nm axes of an Np-cut KGW crystal, respectively. LBO crystals with critical phase matching are used to perform the intracavity SFG of fundamental and Stokes waves. At a pump power of 36 W, the maximum output powers at 707 and 714 nm can reach 2.72 and 3.14 W, corresponding to light-to-light conversion efficiencies of 7.5% and 8.7%, respectively. The developed 707 and 714 nm laser sources are practically useful in laser trapping and cooling related to atomic strontium and radium.

5.
Opt Lett ; 48(6): 1510-1513, 2023 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-36946965

RESUMEN

A compact efficient continuous wave (CW) laser with selectable two wavelengths at 671 and 714 nm is developed. The laser cavity comprises an Nd-doped and an undoped YVO4 crystal to generate the fundamental wave at 1342 nm and the first-Stokes Raman wave at 1525 nm, respectively. A single LBO crystal with the cut angle in the XZ plane is designed to achieve the selectable phase-matching via the thermal tuning for the second harmonic generation (SHG) of 1342 nm and the sum frequency generation (SFG) of 1342 and 1525 nm. At a pump power of 40 W, the optimal output powers at 671 and 714 nm can reach 4.5 and 1.8 W, respectively. The present compact CW laser source at 671 and 714 nm has practical usefulness for laser spectroscopy and numerous applications.

6.
Phys Rev Lett ; 129(11): 111802, 2022 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-36154404

RESUMEN

This Letter reports on the first results from the Taiwan Axion Search Experiment with a Haloscope, a search for axions using a microwave cavity at frequencies between 4.707 50 and 4.798 15 GHz. Apart from the nonaxion signals, no candidates with a significance of more than 3.355 were found. The experiment excludes models with the axion-two-photon coupling |g_{aγγ}|≳8.1×10^{-14} GeV^{-1}, a factor of eleven above the benchmark Kim-Shifman-Vainshtein-Zakharov model, in the mass range 19.4687

7.
Entropy (Basel) ; 24(2)2022 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-35205510

RESUMEN

The resonant modes generated from the modern Chladni experiment are systematically confirmed to intimately correspond to the maximum entropy states obtained from the inhomogeneous Helmholtz equation for the square and equilateral triangle plates. To investigate the origin of maximum entropy states, the inhomogeneous Helmholtz equation is modified to consider the point interaction coming from the driving oscillator. The coupling strength associated with the point interaction is characterized by a dimensionless factor α. The δ potential of the point interaction is numerically modelled by a truncated basis with an upper index N. The asymptotic behavior for the upper index N is thoroughly explored to verify that the coupling strength of α = 1.0 can make the theoretical resonant modes agree excellently with the maximum entropy states as N→∞. It is further authenticated that nearly the same resonant modes can be obtained by using a larger coupling strength α when a smaller upper index N is exploited in the calculation.

8.
Opt Express ; 27(13): 18190-18200, 2019 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-31252766

RESUMEN

We demonstrate the direct generation of visible vortex beams at 640 nm and 607 nm by employing an off-axis pumping scheme in a diode end-pumped Pr3+:YLF laser. A detailed numerical analysis, based on the coherent superposition of Hermite-Gaussian modes with different amplitudes and phases, is perfectly consistent with the experimentally observed lasing modes. The maximum vortex output powers have been measured to be 808 mW and 211 mW at a pump power of 3.16 W, for the wavelengths of 640 nm and 607 nm, respectively. We also demonstrate the handedness control of the generated vortex beam. Such a visible vortex laser can potentially be applied in super-resolution fluorescent microscopes and micro-fabrication research.

9.
Opt Lett ; 44(2): 327-330, 2019 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-30644892

RESUMEN

The design criterion of thermal conductivity for the GaAs/AlAs distributed Bragg reflector (DBR) superlattice structure was thoroughly investigated to precisely analyze the thermal behaviors of the optically pumped vertically external cavity surface-emitting laser (VECSEL). A finite element model with detailed configuration of a VECSEL gain chip was constructed to fulfill the analysis. A 1060 nm VECSEL with different pump conditions was further demonstrated to verify the finite element analysis. At the VECSEL thermal rollover point, the analysis results show that the model with the superlattice property predicts more precise temperature values than that using a bulk composite property. It reveals that the accurate determination of the thermal conductivity of the DBR superlattice is significantly important for the VECSEL thermal analysis.

10.
Opt Lett ; 44(13): 3202-3205, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-31259921

RESUMEN

An efficient LED pumping module is explored for the demonstration of energy scaling of passively Q-switched output to millijoule high-pulse-energy level. For the free-running operation at fundamental wavelength, the highest optical conversion efficiency of 23.7% is reached. By using a Cr4+:YAG crystal as the saturable absorber, the passively Q-switched output energy is up to 14.5 mJ in a compact setup. The laser resonator is further optimized to shorten the output pulse width and to obtain better mode quality. The pulse width of the Q-switched emission is as short as 25 ns, and the peak power is up to 0.7 MW. With such a highly efficient configuration, the extracavity second-harmonic generation at 532 nm can be achieved with 4.5 mJ pulse energy.

11.
Opt Lett ; 43(23): 5753-5756, 2018 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-30499985

RESUMEN

A novel scheme to realize a mode-locked laser with a narrow spectral linewidth is demonstrated by exploiting a reflected Fabry-Perot (FP) cavity to introduce an intense FP effect. Stable continuous-wave mode-locked operation is achieved with the repetition rate of 48 MHz and the maximum average output power of 2.6 W under an incident pump power of 11.9 W. The mode-locked pulse width is systematically investigated by varying the optical thickness of the reflected FP cavity. The pulse duration is experimentally found to be in a range of 0.8 to 2.6 ns. The experimental results reveal that the reflected FP cavity is the key factor leading to the pulse generation in the nanosecond regime. This Letter is believed to provide a promising method for generating optical pulses with narrow spectral linewidths.

12.
Opt Lett ; 42(24): 5226-5229, 2017 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-29240178

RESUMEN

A continuous-wave (cw) self-mode-locked Tm:YAG laser at 2015 nm is successfully demonstrated by suppressing the self-pulsing behavior. By using rate equations to simulate the laser temporal dynamic, the theoretical analysis indicates that the reabsorption-induced self-pulsing for the Tm:YAG laser can be suppressed with sufficient pump power. It is experimentally confirmed that at absorbed powers higher than 6 W, the self-pulsing can be eliminated and a cw self-mode-locked pulse is generated instead of the Q-switched mode locking. At an absorbed power of 6.8 W, the output power of the self-mode-locked Tm:YAG laser reaches 1.22 W with corresponding pulse duration of 3 ps and a repetition rate of 3.376 GHz.

13.
Opt Lett ; 42(12): 2394-2397, 2017 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-28614319

RESUMEN

A LED-array-pumped Nd:YAG laser with optical conversion efficiency up to 20.2% is demonstrated by direct side-pumping without a coupling lens. The 810-nm LED array with a full-width-half-maximum of 30 nm and an area fill factor of 50% is designed to attain high spectral absorption efficiency with a pump density of 151.8 W/cm2. Furthermore, higher than 45% overall coupling efficiency is achieved by placing the LED array as close as possible to the side of the gain medium for overcoming the large pumped divergence. More importantly, by using the efficient pump scheme, the demonstration of a passively Q-switched LED-pumped laser is successfully realized with a pulsed energy of 1.42 mJ.

14.
Opt Lett ; 42(11): 2224-2227, 2017 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-28569887

RESUMEN

A synchronously dual self-mode-locked (SML) operation at 946 and 1064 nm is experimentally accomplished by using a compact coupling scheme to obtain the optical beating frequency up to 35.2 THz. The SML emissions at 946 and 1064 nm are established by a monolithic Nd:YAG cavity and a Nd:YVO4 crystal in a flat-flat cavity, respectively. Two gain media are butt adjoined to be longitudinally pumped by a single laser diode. The monolithic Nd:YAG crystal is used not only as the 946 nm laser cavity, but also as the output coupler of the Nd:YVO4 1064 nm laser. More importantly, the output surface of the monolithic Nd:YAG laser is coated to generate the optical feedback for the synchronization of the dual SML operation. At a pump power of 10.7 W, the output powers at 1064 and 946 nm can simultaneously reach 1.5 W by controlling the focal position of the pump waist.

15.
Sensors (Basel) ; 17(1)2017 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-28117724

RESUMEN

This study presents a new ubiquitous emergency medical service system (UEMS) that consists of a ubiquitous tele-diagnosis interface and a traffic guiding subsystem. The UEMS addresses unresolved issues of emergency medical services by managing the sensor wires for eliminating inconvenience for both patients and paramedics in an ambulance, providing ubiquitous accessibility of patients' biosignals in remote areas where the ambulance cannot arrive directly, and offering availability of real-time traffic information which can make the ambulance reach the destination within the shortest time. In the proposed system, patient's biosignals and real-time video, acquired by wireless biosensors and a webcam, can be simultaneously transmitted to an emergency room for pre-hospital treatment via WiMax/3.5 G networks. Performances of WiMax and 3.5 G, in terms of initialization time, data rate, and average end-to-end delay are evaluated and compared. A driver can choose the route of the shortest time among the suggested routes by Google Maps after inspecting the current traffic conditions based on real-time CCTV camera streams and traffic information. The destination address can be inputted vocally for easiness and safety in driving. A series of field test results validates the feasibility of the proposed system for application in real-life scenarios.


Asunto(s)
Servicios Médicos de Urgencia , Ambulancias , Técnicas Biosensibles , Redes de Comunicación de Computadores , Tecnología Inalámbrica
16.
Opt Express ; 24(24): 27536-27545, 2016 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-27906324

RESUMEN

We presented a Ho:LuAG ceramic laser in-band pumped by a narrow emission line-width Tm fiber laser at 1907 nm. All of potential transitions between 5I7 and 5I8 manifold were discussed to form the Ho's in-band-pump energy level systems, which were not described in details earlier. For the emission band centered at ~2095 nm, both laser absorption and emission transition separately consisted of two groups were first analyzed and observed. Using output couplers (OCs) with different transmittances (T = 6, 10 and 20%), the similar ~0.5 W continuous-wave (CW) output power under an incident pump power of ~4.9 W was obtained, with twin (or triplet) emission bands respectively. The blue shift of center emission wavelengths was observed with the increase of transmittances.

17.
Opt Express ; 23(9): 11755-62, 2015 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-25969266

RESUMEN

A direct image method of surface reflectivities on a cleaved fiber end with a filtered halogen lamp and a TE-cooled CCD with high dynamic range is proposed to measure the multi-wavelength refractive index profiling (RIP). A polished black glass is used to be a reference standard for measuring the absolute reflectivity of the fiber end. With the developed calibration procedures, both the spatially dependent sensitivity and spectral responsivity of the CCD pixels can be eliminated to achieve the high spatial accuracy. Tested fiber is connected with a fiber terminator to prevent errors from the backside return light. With the present method, the RIP can be precisely measured for not only multi-mode fibers but also single-mode fibers.

18.
Opt Express ; 23(24): 30815-20, 2015 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-26698714

RESUMEN

A confocal microspectrophotometer is utilized to scan the surface reflectivities of a polished gradient-index (GRIN) rod in the range of 400 to 900 nm. The pure fused silica is used to be a reference standard for deducing the absolute reflectivities of the Ge-doped core. Then, multi-wavelength refractive index profiles of the Ge-doped core can be further determined based on the Fresnel equation. Moreover, this work shows a connection between the material dispersion of the GRIN rod and the Ge-doped concentrations measured by an energy dispersive spectrometer. Finally, the dependence of the refractive index of the Ge-doped core on the doping concentrations at a certain wavelength can be easily expressed as a linear form.

19.
BMC Pulm Med ; 15: 24, 2015 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-25880649

RESUMEN

BACKGROUND: Polysomnography (PSG) is treated as the gold standard for diagnosing obstructive sleep apnea (OSA). However, it is labor-intensive, time-consuming, and expensive. This study evaluates validity of overnight pulse oximetry as a diagnostic tool for moderate to severe OSA patients. METHODS: A total of 699 patients with possible OSA were recruited for overnight oximetry and PSG examination at the Sleep Center of a University Hospital from Jan. 2004 to Dec. 2005. By excluding 23 patients with poor oximetry recording, poor EEG signals, or respiratory artifacts resulting in a total recording time less than 3 hours; 12 patients with total sleeping time (TST) less than 1 hour, possibly because of insomnia; and 48 patients whose ages less than 20 or more than 85 years old, data of 616 patients were used for further study. By further considering 76 patients with TST < 4 h, a group of 540 patients with TST ≥ 4 h was used to study the effect of insufficient sleeping time. Alice 4 PSG recorder (Respironics Inc., USA) was used to monitor patients with suspected OSA and to record their PSG data. After statistical analysis and feature selection, models built based on support vector machine (SVM) were then used to diagnose moderate and moderate to severe OSA patients with a threshold of AHI = 30 and AHI = 15, respectively. RESULTS: The SVM models designed based on the oxyhemoglobin desaturation index (ODI) derived from oximetry measurements provided an accuracy of 90.42-90.55%, a sensitivity of 89.36-89.87%, a specificity of 91.08-93.05%, and an area under ROC curve (AUC) of 0.953-0.957 for the diagnosis of severe OSA patients; as well as achieved an accuracy of 87.33-87.77%, a sensitivity of 87.71-88.53%, a specificity of 86.38-86.56%, and an AUC of 0.921-0.924 for the diagnosis of moderate to severe OSA patients. The predictive outcome of ODI to diagnose severe OSA patients is better than to diagnose moderate to severe OSA patients. CONCLUSIONS: Overnight pulse oximetry provides satisfactory diagnostic performance in detecting severe OSA patients. Home-styled oximetry may be a tool for severe OSA diagnosis.


Asunto(s)
Oximetría/métodos , Apnea Obstructiva del Sueño/diagnóstico , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oxihemoglobinas , Polisomnografía , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Máquina de Vectores de Soporte
20.
BMC Health Serv Res ; 15: 264, 2015 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-26162748

RESUMEN

BACKGROUND: In this era of ubiquitous information, patient record exchange among hospitals still has technological and individual barriers including resistance to information sharing. Most research on user attitudes has been limited to one type of user or aspect. Because few analyses of attitudes toward electronic patient records (EPRs) have been conducted, understanding the attitudes among different users in multiple aspects is crucial to user acceptance. This proof-of-concept study investigated the attitudes of users toward the inter-hospital EPR exchange system implemented nationwide and focused on discrepant behavioral intentions among three user groups. METHODS: The system was designed by combining a Health Level 7-based protocol, object-relational mapping, and other medical informatics techniques to ensure interoperability in realizing patient-centered practices. After implementation, three user-specific questionnaires for physicians, medical record staff, and patients were administered, with a 70 % response rate. The instrument showed favorable convergent construct validity and internal consistency reliability. Two dependent variables were applied: the attitudes toward privacy and support. Independent variables comprised personal characteristics, work characteristics, human aspects, and technology aspects. Major statistical methods included exploratory factor analysis and general linear model. RESULTS: The results from 379 respondents indicated that the patients highly agreed with privacy protection by their consent and support for EPRs, whereas the physicians remained conservative toward both. Medical record staff was ranked in the middle among the three groups. The three user groups demonstrated discrepant intentions toward privacy protection and support. Experience of computer use, level of concerns, usefulness of functions, and specifically, reason to use electronic medical records and number of outpatient visits were significantly associated with the perceptions. Overall, four categories of independent variables were associated with the mean difference in the perceptions. CONCLUSIONS: Discrepant attitudes toward privacy and support among the three user groups are identified. Patients may require further education and communication regarding the system. Culturally fit e-Consent should be incorporated into the system to fully utilize the computing power of the Internet when also considering workload. The concern for misuse of EPRs might lead to low support among physicians. Highly readable EPR documents and managerial incentives for information exchange may improve system use.


Asunto(s)
Registros Electrónicos de Salud , Conocimientos, Actitudes y Práctica en Salud , Difusión de la Información , Cuerpo Médico de Hospitales/psicología , Pacientes/psicología , Médicos/psicología , Actitud hacia los Computadores , Femenino , Humanos , Internet , Masculino , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA