Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Optom Vis Sci ; 101(2): 124-128, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38408310

RESUMEN

SIGNIFICANCE: Vision health disparities largely stem from inaccessibility to vision specialists. To improve patient access to vision tests and to expedite clinical workflows, it is important to assess the viability of virtual reality (VR) as a modality for evaluating contrast sensitivity. PURPOSE: This study aimed to assess the validity of a VR version of the Pelli-Robson contrast sensitivity test by comparing its results with those of the corresponding in-office test. METHODS: Twenty-eight participants (mean ± standard deviation age, 37.3 ± 20.5 years) with corrected vision were recruited for testing on a voluntary basis with randomized administration of the in-office test followed by the VR analog or vice versa. Nineteen participants took each test twice to assess test-retest consistency in each modality. Virtual reality tests were conducted on a commercial Pico Neo Eye 2 VR headset, which has a 4K screen resolution. The environment for both tests was controlled by the participant for location and lighting. RESULTS: Similar sensitivity scores were obtained between testing modalities in both the right (n = 28 participants; Wilcoxon match-paired signed rank [SR], p=0.7) and left eyes (n = 28 participants; Wilcoxon match-paired SR, p=0.7). In addition, similar test-retest scores were found for VR (n = 19 participants; Wilcoxon match-paired SR, p=1.0) or in-office (n = 19 participants; Wilcoxon match-paired SR, p=1.0) tests. Virtual reality Pelli-Robson results correlated well with in-office test results in variably diseased participants (n = 14 eyes from 7 participants, R2 = 0.93, p<0.0001). CONCLUSIONS: In this pilot trial, we demonstrated that VR Pelli-Robson measurements of corrected vision align with those of in-office modalities, suggesting that this may be a reliable method of implementing this test in a more interactive and accessible manner.


Asunto(s)
Sensibilidad de Contraste , Realidad Virtual , Humanos , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Proyectos Piloto , Pruebas de Visión/métodos
2.
Am J Otolaryngol ; 45(4): 104303, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38678799

RESUMEN

Otolaryngologists can enhance workflow efficiency, provide better patient care, and advance medical research and education by integrating artificial intelligence (AI) into their practices. GPT-4 technology is a revolutionary and contemporary example of AI that may apply to otolaryngology. The knowledge of otolaryngologists should be supplemented, not replaced when using GPT-4 to make critical medical decisions and provide individualized patient care. In our thorough examination, we explore the potential uses of the groundbreaking GPT-4 technology in the field of otolaryngology, covering aspects such as potential outcomes and technical boundaries. Additionally, we delve into the intricate and intellectually challenging dilemmas that emerge when incorporating GPT-4 into otolaryngology, considering the ethical considerations inherent in its implementation. Our stance is that GPT-4 has the potential to be very helpful. Its capabilities, which include aid in clinical decision-making, patient care, and administrative job automation, present exciting possibilities for enhancing patient outcomes, boosting the efficiency of healthcare delivery, and enhancing patient experiences. Even though there are still certain obstacles and limitations, the progress made so far shows that GPT-4 can be a valuable tool for modern medicine. GPT-4 may play a more significant role in clinical practice as technology develops, helping medical professionals deliver high-quality care tailored to every patient's unique needs.


Asunto(s)
Inteligencia Artificial , Otolaringología , Humanos , Otolaringología/ética , Inteligencia Artificial/ética , Toma de Decisiones Clínicas/ética
3.
J Vasc Surg ; 78(4): 902-911, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37236516

RESUMEN

OBJECTIVE: This study quantified respiratory-induced dynamics of branch vessels before and after thoracoabdominal aortic aneurysm (TAAA) branched endovascular aneurysm repair (bEVAR). METHODS: Patients with TAAA were recruited prospectively and treated with bEVAR, predominantly with Zenith t-Branch and BeGraft Peripheral PLUS bridging stents. Using SimVascular software, three-dimensional geometric models of the vessels and implants were constructed from computed tomography angiograms during both inspiratory and expiratory breath-holds, preoperatively and postoperatively. From these models, branch take-off angles, end-stent angles (transition from distal end of stent to native artery), and curvatures were computed. Paired, two-tailed t tests were performed to compare inspiratory vs expiratory geometry and pre- vs postoperative deformations. RESULTS: We evaluated 52 (12 celiac arteries [CA], 15 superior mesenteric arteries [SMA], and 25 renal arteries [RA]) branched renovisceral vessels with bridging stents in 15 patients. Implantation of bridging stents caused branch take-off angle to shift inferiorly in the SMA (P = .015) and RA (P = .014) and decreased the respiratory-induced branch angle motion in the CA and SMA by approximately 50%. End-stent angle increased from before to after bEVAR for the CA (P = .005), SMA (P = .020), and RA (P < .001); however, respiratory-induced deformation was unchanged. Bridging stents did not experience significant bending owing to respiration. CONCLUSIONS: The decrease in respiratory-induced deformation of branch take-off angle from before to after bEVAR should decrease the risk of device disengagement and endoleak. The unchanging respiratory-induced end-stent bending, from before to after bEVAR, means that bEVAR maintains native vessel dynamics distal to the bridging stents. This factor minimizes the risk of tissue irritation owing to respiratory cycles, boding well for branch vessel patency. The longer bridging stent paths associated with bEVAR may enable smoother paths subject to less dynamic bending, and potentially lower fatigue risk, compared with fenestrated EVAR.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Reparación Endovascular de Aneurismas , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Stents , Arteria Celíaca/cirugía , Resultado del Tratamiento , Diseño de Prótesis , Estudios Retrospectivos
4.
J Endovasc Ther ; : 15266028231179592, 2023 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-37300396

RESUMEN

PURPOSE: Type B aortic dissections propagate with either achiral (nonspiraling) or right-handed chiral (spiraling) morphology, have mobile dissection flaps, and are often treated with thoracic endovascular aortic repair (TEVAR). We aim to quantify cardiac-induced helical deformation of the true lumen of type B aortic dissections before and after TEVAR. MATERIAL AND METHODS: Retrospective cardiac-gated computed tomography (CT) images before and after TEVAR of type B aortic dissections were used to construct systolic and diastolic 3-dimensional (3D) surface models, including true lumen, whole lumen (true+false lumens), and branch vessels. This was followed by extraction of true lumen helicity (helical angle, twist, and radius) and cross-sectional (area, circumference, and minor/major diameter ratio) metrics. Deformations between systole and diastole were quantified, and deformations between pre- and post-TEVAR were compared. RESULTS: Eleven TEVAR patients (59.9±4.6 years) were included in this study. Pre-TEVAR, there were no significant cardiac-induced deformations of helical metrics; however, post-TEVAR, significant deformation was observed for the true lumen proximal angular position. Pre-TEVAR, cardiac-induced deformations of all cross-sectional metrics were significant; however, only area and circumference deformations remained significant post-TEVAR. There were no significant differences of pulsatile deformation from pre- to post-TEVAR. Variance of proximal angular position and cross-sectional circumference deformation decreased after TEVAR. CONCLUSION: Pre-TEVAR, type B aortic dissections did not exhibit significant helical cardiac-induced deformation, indicating that the true and false lumens move in unison (do not move with respect to each other). Post-TEVAR, true lumens exhibited significant cardiac-induced deformation of proximal angular position, suggesting that exclusion of the false lumen leads to greater rotational deformations of the true lumen and lack of true lumen major/minor deformation post-TEVAR means that the endograft promotes static circularity. Population variance of deformations is muted after TEVAR, and dissection acuity influences pulsatile deformation while pre-TEVAR chirality does not. CLINICAL IMPACT: Description of thoracic aortic dissection helical morphology and dynamics, and understanding the impact of thoracic endovascular aortic repair (TEVAR) on dissection helicity, are important for improving endovascular treatment. These findings provide nuance to the complex shape and motion of the true and false lumens, enabling clinicians to better stratify dissection disease. The impact of TEVAR on dissection helicity provides a description of how treatment alters morphology and motion, and may provide clues for treatment durability. Finally, the helical component to endograft deformation is important to form comprehensive boundary conditions for testing and developing new endovascular devices.

5.
J Endovasc Ther ; : 15266028231187741, 2023 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-37485662

RESUMEN

PURPOSE: This study presents analytic techniques to quantify cardiac pulsatility-induced deformations of thoracic aortic endografts in patients with thoracic aortic aneurysm (TAA), dissection (TAD), and blunt thoracic aortic injury (BTAI) after thoracic endovascular aortic repair (TEVAR). TECHNIQUE: We analyzed 19 image data sets from 14 patients treated for TAA, TAD, and BTAI with cardiac-gated post-TEVAR CTs. Systolic and diastolic geometric models were constructed and diametric, axial, and bending deformations were quantified. For patients with cardiac-gated pre-op scans, the damping of pulsatile diametric distension was computed. Maximum localized diametric distension was 2.4±1.0%, 4.2±1.7%, and 5.5±1.6%, and axial deformation was 0.0±0.1%, -0.1±0.3%, and 1.1±0.6% in the endografts of TAA, TAD, and BTAI cohorts, respectively. Diametric distension damping from pre- to post-TEVAR was ~50%. Diametric and bending deformations were localized at certain axial positions on the endograft, and the inner curve bends more than the centerline, especially adjacent to overlapping regions. CONCLUSION: The presented techniques support investigation of multi-axial endograft deformations between disease causes and geometric locations on the device. Discretized quantification of deformation is needed to define device fatigue testing conditions and predict device durability in patients. CLINICAL IMPACT: This study demonstrates analytic techniques to quantify discretized deformation of thoracic endografts. Cardiac-resolved computed tomography is sometimes acquired for surgical planning and follow-up, however, the dynamic data are not typically used to quantify pulsatile deformations. Our analytic techniques extract the centerline and surface geometry of the stented thoracic aorta during the cardiac cycle, which are used to quantify diametric, axial, and bending deformations to provide better understanding of device durability and impact on the native anatomy.

6.
J Endovasc Ther ; : 15266028231168351, 2023 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-37144300

RESUMEN

PURPOSE: We aim to quantify multiaxial cardiac pulsatility-induced deformation of the thoracic aorta after ascending thoracic endovascular aortic repair (TEVAR) as a part of the GORE ARISE Early Feasibility Study. MATERIALS AND METHODS: Fifteen patients (7 females and 8 males, age 73±9 years) with ascending TEVAR underwent computed tomography angiography with retrospective cardiac gating. Geometric modeling of the thoracic aorta was performed; geometric features including axial length, effective diameter, and centerline, inner surface, and outer surface curvatures were quantified for systole and diastole; and pulsatile deformations were calculated for the ascending aorta, arch, and descending aorta. RESULTS: From diastole to systole, the ascending endograft exhibited straightening of the centerline (0.224±0.039 to 0.217±0.039 cm-1, p<0.05) and outer surface (0.181±0.028 to 0.177±0.029 cm-1, p<0.05) curvatures. No significant changes were observed for inner surface curvature, diameter, or axial length in the ascending endograft. The aortic arch did not exhibit any significant deformation in axial length, diameter, or curvature. The descending aorta exhibited small but significant expansion of effective diameter from 2.59±0.46 to 2.63±0.44 cm (p<0.05). CONCLUSION: Compared with the native ascending aorta (from prior literature), ascending TEVAR damps axial and bending pulsatile deformations of the ascending aorta similar to how descending TEVAR damps descending aortic deformations, while diametric deformations are damped to a greater extent. Downstream diametric and bending pulsatility of the native descending aorta was muted compared with that in patients without ascending TEVAR (from prior literature). Deformation data from this study can be used to evaluate the mechanical durability of ascending aortic devices and inform physicians about the downstream effects of ascending TEVAR to help predict remodeling and guide future interventional strategies. CLINICAL IMPACT: This study quantified local deformations of both stented ascending and native descending aortas to reveal the biomechanical impact of ascending TEVAR on the entire thoracic aorta, and reported that the ascending TEVAR muted cardiac-induced deformation of the stented ascending aorta and native descending aorta. Understanding of in vivo deformations of the stented ascending aorta, aortic arch and descending aorta can inform physicians about the downstream effects of ascending TEVAR. Notable reduction of compliance may lead to cardiac remodeling and long-term systemic complications. This is the first report which included dedicated deformation data regarding ascending aortic endograft from clinical trial.

7.
Vascular ; 31(2): 234-243, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34963378

RESUMEN

OBJECTIVE: Practice patterns and durability of parallel stent graft techniques in complex endovascular aneurysm repair (EVAR) remain poorly defined. We aimed to quantify and compare the impact of renal chimney intra-aortic stent length (IASL) on geometric deformations of renal arteries in complex EVAR. METHODS: Thirty-eight nonconsecutive patients underwent EVAR utilizing parallel stent graft techniques (chimney EVAR [chEVAR], n = 28; chimney endovascular aneurysm sealing [chEVAS], n = 10) between 2010 and 2016. A total of 59 renal chimney stent grafts were used. Geometric quantification was derived from three-dimensional model-based centerline extraction. Renal chimney intra-aortic stent length (IASL) was defined as the length of chimney stent that extended from the proximal edge of the chimney stent to the ostium of the corresponding renal artery. RESULTS: Mean IASL for both left and right renal arteries in the cohort was 35.7 mm. Renal arteries containing chimney IASL <30 mm trended toward a greater branch angle (135.4 vs. 127.8°, p = .06). Left renal arteries showed significantly greater branch angle among those with IASL <40 mm (135.5 vs. 121.7°, p = .045). Mean IASL for renal arteries in chEVAR was significantly longer compared to chEVAS (39.2 vs. 26.3 mm, p = .003). No difference was noted in overall branch angle or end-stent angle based on procedure type. ChEVAR with IASL <30 mm had significantly greater end-stent angle (48.2 vs. 33.5°, p = .03). In contrast, chEVAS patients showed no difference in end-stent angle based on IASL thresholds, but did have significantly greater branch angle among those with IASL <30 mm when grouped by both all renal arteries (133.5 vs. 113.5°, p = .004) and right renal arteries (134.3 vs. 111.6°, p = .02). CONCLUSIONS: Renal chimney stents with longer IASL appear to exhibit less renal artery deformation, suggesting a more gradual and perpendicular transition of the chimney stent across the renal ostium.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Reparación Endovascular de Aneurismas , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Aortografía/métodos , Stents , Diseño de Prótesis
8.
Am J Physiol Heart Circ Physiol ; 320(2): H901-H911, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-33382638

RESUMEN

Chirality is a fundamental property in many biological systems. Motivated by previous observations of helical aortic blood flow, aortic tissue fibers, and propagation of aortic dissections, we introduce methods to characterize helical morphology of aortic dissections. After validation on computer-generated phantoms, the methods were applied to patients with type B dissection. For this cohort, there was a distinct bimodal distribution of helical propagation of the dissection with either achiral or exclusively right-handed chirality, with no intermediate cases or left-handed cases. This clear grouping indicates that dissection propagation favors these two modes, which is potentially due to the right-handedness of helical aortic blood flow and cell orientation. The characterization of dissection chirality and quantification of helical morphology advances our understanding of dissection pathology and lays a foundation for applications in clinical research and treatment practice. For example, the chirality and magnitude of helical metrics of dissections may indicate risk of dissection progression, help define treatment and surveillance strategies, and enable development of novel devices that account for various helical morphologies.NEW & NOTEWORTHY A novel definition of helical propagation of type B aortic dissections reveals a distinct bimodality, with the true lumen being either achiral (nonhelical) or exclusively right-handed. This right-handed chirality is consistent with anatomic and physiological phenomena such as right-handed twist during left ventricle contraction, helical blood flow, and tissue fiber direction. The helical character of aortic dissections may be useful for pathology research, diagnostics, treatment selection, therapeutic durability prediction, and aortic device design.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Disección Aórtica/diagnóstico por imagen , Aortografía , Angiografía por Tomografía Computarizada , Adulto , Anciano , Anciano de 80 o más Años , Disección Aórtica/fisiopatología , Aorta Torácica/fisiopatología , Aneurisma de la Aorta Torácica/fisiopatología , Aortografía/instrumentación , Angiografía por Tomografía Computarizada/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Valor Predictivo de las Pruebas , Interpretación de Imagen Radiográfica Asistida por Computador , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados
9.
J Vasc Surg ; 74(5): 1499-1507.e1, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33940073

RESUMEN

OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) can change the morphology of the flow lumen in aortic dissections, which may affect aortic hemodynamics and function. This study characterizes how the helical morphology of the true lumen in type B aortic dissections is altered by TEVAR. METHODS: Patients with type B aortic dissection who underwent computed tomography angiography before and after TEVAR were retrospectively reviewed. Images were used to construct three-dimensional stereolithographic surface models of the true lumen and whole aorta using custom software. Stereolithographic models were segmented and co-registered to determine helical morphology of the true lumen with respect to the whole aorta. The true lumen region covered by the endograft was defined based on fiducial markers before and after TEVAR. The helical angle, average helical twist, peak helical twist, and cross-sectional eccentricity, area, and circumference were quantified in this region for pre- and post-TEVAR geometries. RESULTS: Sixteen patients (61.3 ± 8.0 years; 12.5% female) were treated successfully for type B dissection (5 acute and 11 chronic) with TEVAR and scans before and after TEVAR were retrospectively obtained (follow-up interval 52 ± 91 days). From before to after TEVAR, the true lumen helical angle (-70.0 ± 71.1 to -64.9 ± 75.4°; P = .782), average helical twist (-4.1 ± 4.0 to -3.7 ± 3.8°/cm; P = .674), and peak helical twist (-13.2 ± 15.2 to -15.4 ± 14.2°/cm; P = .629) did not change. However, the true lumen helical radius (1.4 ± 0.5 to 1.0 ± 0.6 cm; P < .05) and eccentricity (0.9 ± 0.1 to 0.7 ± 0.1; P < .05) decreased, and the cross-sectional area (3.0 ± 1.1 to 5.0 ± 2.0 cm2; P < .05) and circumference (7.1 ± 1.0 to 8.0 ± 1.4 cm; P < .05) increased significantly from before to after TEVAR. The distinct bimodal distribution of chiral and achiral native dissections disappeared after TEVAR, and subgroup analyses showed that the true lumen circumference of acute dissections increased with TEVAR, although it did not for chronic dissections. CONCLUSIONS: The unchanged helical angle and average and peak helical twists as a result of TEVAR suggest that the angular positions of the true lumen are constrained and that the endografts were helically conformable in the angular direction. The decrease of helical radius indicated a straightening of the corkscrew shape of the true lumen, and in combination with more circular and expanded lumen cross-sections, TEVAR produced luminal morphology that theoretically allows for lower flow resistance through the endografted portion. The impact of TEVAR on dissection flow lumen morphology and the interaction between endografts and aortic tissue can provide insight for improving device design, implantation technique, and long-term clinical outcomes.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Aortografía , Implantación de Prótesis Vascular , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares , Tomografía Computarizada Espiral , Anciano , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/fisiopatología , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/fisiopatología , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Diseño de Prótesis , Flujo Sanguíneo Regional , Estudios Retrospectivos , Stents , Factores de Tiempo , Resultado del Tratamiento
10.
Ann Vasc Surg ; 70: 197-201, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32335254

RESUMEN

We describe a novel endovascular technique in which three 0.014″ guidewires are placed in parallel through a 0.035″ lumen catheter, in order to create a stiff platform to allow for delivery of 0.035″ profile devices through challenging anatomy. Three illustrative cases are presented: a difficult aortic bifurcation during lower extremity intervention, a tortuous internal iliac artery during placement of an iliac branch device, and salvage of a renal artery after inadvertent coverage during proximal cuff deployment for type 1a endoleak. We also quantify the relative stiffness of the triple 0.014″ wire configuration, using several well-known 0.035″ wires for comparison. The "triple wire technique" is an effective method for tracking endovascular devices through difficult tortuous anatomy, and can be used in a variety of clinical settings. The technique is especially useful when a traditional, stiff 0.035″ wire will not track without "kicking out." Each 0.014″ wire is reasonably soft and traverses the tortuous vessel easily, but when the 3 wires are used together as a rail it provides a stiff enough platform for delivery.


Asunto(s)
Implantación de Prótesis Vascular/instrumentación , Endofuga/cirugía , Procedimientos Endovasculares/instrumentación , Arteria Femoral/cirugía , Aneurisma Ilíaco/cirugía , Extremidad Inferior/irrigación sanguínea , Enfermedad Arterial Periférica/cirugía , Dispositivos de Acceso Vascular , Anciano , Anciano de 80 o más Años , Prótesis Vascular , Endofuga/tratamiento farmacológico , Diseño de Equipo , Femenino , Arteria Femoral/diagnóstico por imagen , Humanos , Aneurisma Ilíaco/diagnóstico por imagen , Masculino , Enfermedad Arterial Periférica/diagnóstico por imagen , Docilidad , Stents
11.
J Vasc Surg ; 72(4): 1196-1205, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32035770

RESUMEN

OBJECTIVE: Aortic geometry has been shown to influence the development of endograft malapposition (bird-beaking) in thoracic endovascular aortic repair (TEVAR), but the extent of this relationship lacks clarity. The aim of this study was to develop a reproducible method of measuring bird-beak severity and to investigate preoperative geometry associated with bird-beaking. METHODS: The study retrospectively analyzed 20 patients with thoracic aortic aneurysms or type B dissections treated with TEVAR. Computed tomography scans were used to construct three-dimensional geometric models of the preoperative and postoperative aorta and endograft. Postoperative bird-beaking was quantified with length, height, and angle; categorized into a bird-beak group (BBG; n = 10) and no bird-beak group (NBBG; n = 10) using bird-beak height ≥5 mm as a threshold; and correlated to preoperative metrics including aortic cross-sectional area, inner curvature, diameter, and inner curvature × diameter as well as graft diameter and oversizing at the proximal landing zone. RESULTS: Aortic area (1002 ± 118 mm2 vs 834 ± 248 mm2), inner curvature (0.040 ± 0.014 mm-1 vs 0.031 ± 0.012 mm-1), and diameter (35.7 ± 2.1 mm vs 32.2 ± 4.9 mm) were not significantly different between BBG and NBBG; however, inner curvature × diameter was significantly higher in BBG (1.4 ± 0.5 vs 1.0 ± 0.3; P = .030). Inner curvature and curvature × diameter were significantly correlated with bird-beak height (R = 0.462, P = .041; R = 0.592, P = .006) and bird-beak angle (R = 0.680, P < .001; R = 0.712, P < .001). CONCLUSIONS: TEVAR bird-beak severity can be quantified and predicted with geometric modeling techniques, and the combination of high preoperative aortic inner curvature and diameter increases the risk for development of TEVAR bird-beaking.


Asunto(s)
Aorta Torácica/anatomía & histología , Aneurisma de la Aorta Torácica/cirugía , Endofuga/epidemiología , Procedimientos Endovasculares/efectos adversos , Stents/efectos adversos , Anciano , Anciano de 80 o más Años , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aortografía , Endofuga/diagnóstico , Endofuga/etiología , Endofuga/prevención & control , Procedimientos Endovasculares/instrumentación , Falla de Equipo , Estudios de Factibilidad , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Modelos Anatómicos , Periodo Preoperatorio , Estudios Retrospectivos , Medición de Riesgo/métodos , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X
12.
J Biomech Eng ; 142(4)2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-31633168

RESUMEN

Precise description of vascular morphometry is crucial to support medical device manufacturers and clinicians for improving device development and interventional outcomes. A compact and intuitive method is presented to automatically characterize the surface geometry of tubular anatomic structures and quantify surface curvatures starting from generic stereolithographic (STL) surfaces. The method was validated with software phantoms and used to quantify the longitudinal surface curvatures of 37 human thoracic aortas with aneurysm or dissection. The quantification of surface curvatures showed good agreement with analytic solutions from the software phantoms, and demonstrated better agreement as compared to estimation methods using only centerline geometry and cross-sectional radii. For the human thoracic aortas, longitudinal inner surface curvature was significantly higher than centerline curvature (0.33 ± 0.06 versus 0.16 ± 0.02 cm-1 for mean; 1.38 ± 0.48 versus 0.45 ± 0.11 cm-1 for peak; both p < 0.001). These findings show the importance of quantifying surface curvatures in order to better describe the geometry and biomechanical behavior of the thoracic aorta, which can assist in treatment planning and supplying device manufactures with more precise boundary conditions for mechanical evaluation.


Asunto(s)
Aorta Torácica , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Transversales , Humanos , Imagenología Tridimensional , Modelos Cardiovasculares , Fantasmas de Imagen
13.
J Endovasc Ther ; 26(4): 556-564, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31210077

RESUMEN

Purpose: To quantify deformations of renal arteries and snorkel stents after snorkel endovascular aneurysm sealing (Sn-EVAS) resulting from cardiac pulsatility and respiration and compare these deformations to patients with untreated abdominal aortic aneurysms (AAA) and snorkel endovascular aneurysm repair (Sn-EVAR). Materials and Methods: Ten Sn-EVAS patients (mean age 75±6 years; 8 men) were scanned with cardiac-gated, respiration-resolved computed tomography angiography. From 3-dimensional geometric models, changes in renal artery and stent angulation and curvature due to cardiac pulsatility and respiration were quantified. Respiration-induced motions were compared with those of 16 previously reported untreated AAA patients and 11 Sn-EVAR patients. Results: Renal artery bending at the stent end was greater for respiratory vs cardiac influences (6°±7° vs -1°±2°, p<0.025). Respiration caused a 3-fold greater deformation on the left renal artery as compared with the right side. Maximum curvature change was higher for respiratory vs cardiac influences (0.49±0.29 vs 0.24±0.17 cm-1, p<0.025), and snorkel renal stents experienced similar maximum curvature change due to cardiac pulsatility and respiration (0.14±0.10 vs 0.19±0.09 cm-1, p=0.142). When comparing the 3 patient cohorts for respiratory-induced deformation, there was significant renal branch angulation in untreated AAAs, but not in Sn-EVAR or Sn-EVAS, and there was significant bending at the stent end in Sn-EVAR and Sn-EVAS. Maximum curvature change due to respiration was ~10-fold greater in Sn-EVAR and Sn-EVAS compared to untreated AAAs. Conclusion: The findings suggest that cardiac and respiratory influences may challenge the mechanical durability of snorkel stents of Sn-EVAS; similarly, however, respiration may be the primary culprit for tissue irritation, increasing the risk for stent-end thrombosis, especially in the left renal artery. The bending stiffness of snorkel stents in both the Sn-EVAR and Sn-EVAS cohorts damped renal branch angulation while it intensified bending of the artery distal to the snorkel stent. Understanding these device-to-artery interactions is critical as they may affect mechanical durability of branch stents and quality and durability of treatment.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Flujo Pulsátil , Arteria Renal/cirugía , Respiración , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Aortografía , Implantación de Prótesis Vascular/efectos adversos , Técnicas de Imagen Sincronizada Cardíacas , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Diseño de Prótesis , Arteria Renal/diagnóstico por imagen , Arteria Renal/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
14.
Ann Vasc Surg ; 61: 410-415, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31319171

RESUMEN

BACKGROUND: The iliofemoropopliteal artery significantly changes path length during normal hip and knee flexion. Prosthetic bypass grafts, such as polytetrafluoroethylene (PTFE) grafts, are relatively stiff and thus can subject graft anastomoses to high tension when the path length increases. The aim of this study was to examine the influence of length redundancy and twist on the biomechanical properties of PTFE bypass grafts. METHODS: Unreinforced and ring-reinforced PTFE grafts were loaded in an axial mechanical testing machine to measure the tensile and compressive axial forces with varying levels of length redundancy and axial twist. RESULTS: Adding 5-15% length redundancy to a graft decreases the force to cause 5% extension by > 90% without substantially increasing shortening forces. Adding 4.5°/cm of axial twist imparts a corkscrew shape to the graft without increasing extension or shortening forces in the presence of length redundancy. Ring-reinforced PTFE grafts require more length redundancy to experience these reductions in forces especially in the presence of axial twist. CONCLUSIONS: A modest amount of length redundancy and twist (i.e., a cork-screw condition) confers improved biomechanical properties in a PTFE graft, especially in ring-reinforced grafts. This should be taken into consideration when fashioning an arterial bypass graft in the iliofemoropopliteal segment.


Asunto(s)
Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Hemodinámica , Extremidad Inferior/irrigación sanguínea , Politetrafluoroetileno/química , Diseño de Prótesis , Fenómenos Biomecánicos , Fuerza Compresiva , Elasticidad , Ensayo de Materiales , Falla de Prótesis , Estrés Mecánico , Resistencia a la Tracción
15.
Ann Vasc Surg ; 52: 312.e7-312.e12, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29775657

RESUMEN

The Nellix device uses polymer-filled endobags to stabilize the abdominal aortic aneurysm (AAA) sac which is described as endovascular aneurysm sealing (EVAS). We analyzed cardiac-gated computed tomography angiography scans of repaired AAA with EVAS in 4 patients to evaluate the geometry and cardiac pulsatility-induced deformation. Graft translation and aortic curvature changes were found to be minimal during the cardiac cycle. The mean ± standard deviation changes in renal-aorta angles (1.0 ± 0.9°) were less than the changes in the superior mesenteric artery-aorta angle (4.0 ± 2.1°) (P < 0.01), during the cardiac cycle, demonstrating greater stabilization of the visceral branches closer to the device. These findings confirm stabilization of the abdominal aorta during the cardiac cycle using EVAS.


Asunto(s)
Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Flujo Pulsátil , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Aortografía/métodos , Técnicas de Imagen Sincronizada Cardíacas , Angiografía por Tomografía Computarizada , Humanos , Imagenología Tridimensional , Modelación Específica para el Paciente , Diseño de Prótesis , Interpretación de Imagen Radiográfica Asistida por Computador , Flujo Sanguíneo Regional , Resultado del Tratamiento
16.
Ann Vasc Surg ; 46: 83-89, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28887263

RESUMEN

BACKGROUND: Thoracic endovascular aortic repair (TEVAR) has dramatically expanded treatment options for patients with thoracic aortic pathology. The interaction between endografts and the dynamic anatomy of the thoracic aorta is not well characterized for repetitive physiologic stressors and subsequent issues related to long-term durability. Through three-dimensional (3D) modeling we sought to quantify cardiac-induced aortic deformation before and after TEVAR to assess the impact of endografts on dynamic aortic anatomy. METHODS: Eight patients with acute (n = 4) or chronic (n = 3) type B dissections, or chronic arch aneurysm (n = 1), underwent TEVAR with a single (n = 5) or multiple (n = 3) Gore C-TAG(s). Cardiac-resolved thoracic CT images were acquired pre- and post-TEVAR. 3D models of thoracic aorta and branch vessels were constructed in systole and diastole. Axial length, mean, and peak curvature of the ascending aorta, arch, and stented lumens were computed from the aortic lumen centerline, delineated with branch vessel landmarks. Cardiac-induced deformation was computed from mid-diastole to end-systole. RESULTS: Pre-TEVAR, there were no significant cardiac-induced changes for aortic axial length or mean curvature. Post-TEVAR, the ascending aorta increased in axial length (2.7 ± 3.1%, P < 0.05) and decreased in mean curvature (0.38 ± 0.05 → 0.36 ± 0.05 cm-1, P < 0.05) from diastole to systole. From pre- to post-TEVAR, axial length change increased in the ascending aorta (P < 0.02), mean curvature decreased in the arch and stented aorta (P < 0.03), and peak curvature decreased in the stented aorta (P < 0.05). CONCLUSIONS: TEVAR for a range of indications not only causes direct geometric changes to the stented aorta but also results in dynamic changes to the ascending and stented aorta. In our cohort, endograft placement straightens the stented aorta and mutes cardiac-induced bending due to longitudinal stiffness. This is compensated by greater length and curvature changes from diastole to systole in the ascending aorta, relative to pre-TEVAR.


Asunto(s)
Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Hemodinámica , Modelos Cardiovasculares , Modelación Específica para el Paciente , Enfermedad Aguda , Anciano , Anciano de 80 o más Años , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/fisiopatología , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/fisiopatología , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/fisiopatología , Aortografía/métodos , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Enfermedad Crónica , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Diseño de Prótesis , Interpretación de Imagen Radiográfica Asistida por Computador , Stents , Resultado del Tratamiento
17.
Ann Vasc Surg ; 43: 85-95, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28390918

RESUMEN

BACKGROUND: Aneurysm regression and target vessel patency during early and mid-term follow-up may be related to the effect of stent-graft configuration on the anatomy. We quantified geometry and remodeling of the renal arteries and aneurysm following fenestrated (F-) or snorkel/chimney (Sn-) endovascular aneurysm repair (EVAR). METHODS: Twenty-nine patients (mean age, 76.8 ± 7.8 years) treated with F- or Sn-EVAR underwent computed tomography angiography at preop, postop, and follow-up. Three-dimensional geometric models of the aorta and renal arteries were constructed. Renal branch angle was defined relative to the plane orthogonal to the aorta. End-stent angle was defined as the angulation between the stent and native distal artery. Aortic volumes were computed for the whole aorta, lumen, and their difference (excluded lumen). Renal patency, reintervention, early mortality, postoperative renal impairment, and endoleak were reviewed. RESULTS: From preop to postop, F-renal branches angled upward, Sn-renal branches angled downward (P < 0.05), and Sn-renals exhibited increased end-stent angulation (12 ± 15°, P < 0.05). From postop to follow-up, branch angles did not change for either F- or Sn-renals, whereas F-renals exhibited increased end-stent angulation (5 ± 10°, P < 0.05). From preop to postop, whole aortic and excluded lumen volumes increased by 5 ± 14% and 74 ± 81%, whereas lumen volume decreased (39 ± 27%, P < 0.05). From postop to follow-up, whole aortic and excluded lumen volumes decreased similarly (P < 0.05), leaving the lumen volume unchanged. At median follow-up of 764 days (range, 7-1,653), primary renal stent patency was 94.1% and renal impairment occurred in 2 patients (6.7%). CONCLUSIONS: Although F- and Sn-EVAR resulted in significant, and opposite, changes to renal branch angle, only Sn-EVAR resulted in significant end-stent angulation increase. Longitudinal geometric analysis suggests that these anatomic alterations are primarily generated early as a consequence of the procedure itself and, although persistent, they show no evidence of continued significant change during the subsequent postoperative follow-up period.


Asunto(s)
Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Arteria Renal/cirugía , Anciano , Anciano de 80 o más Años , Aorta Abdominal/fisiopatología , Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Aortografía/métodos , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares/instrumentación , Femenino , Humanos , Imagenología Tridimensional , Masculino , Modelación Específica para el Paciente , Diseño de Prótesis , Interpretación de Imagen Radiográfica Asistida por Computador , Arteria Renal/diagnóstico por imagen , Arteria Renal/fisiopatología , Stents , Resultado del Tratamiento , Grado de Desobstrucción Vascular , Remodelación Vascular
18.
J Vasc Surg ; 63(4): 922-9, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26755068

RESUMEN

OBJECTIVE: The durability of stent grafts may be related to how procedures and devices alter native anatomy. We aimed to quantify and compare renal artery geometry before and after fenestrated (F-) or snorkel/chimney (Sn-) endovascular aneurysm repair (EVAR). METHODS: Forty patients (75 ± 6 years) underwent computed tomographic angiography before and after F-EVAR (n = 21) or Sn-EVAR (n = 19), with a total of 72 renal artery stents. Renal artery geometry was quantified using three-dimensional model-based centerline extraction. The stented length was computed from the vessel origin to the stent end. The branch angle was computed relative to the orthogonal configuration with respect to the aorta. The end-stent angle was computed relative to the distal native renal artery. Peak curvature was defined as the inverse of the radius of the circumscribed circle at the highest curvature within the proximal portion from the origin to the stent end and the distal portion from the stent end to the first renal artery bifurcation. RESULTS: Sn-renals had greater stented length compared to F-renals (P < .05). From the pre- to the postoperative period, the origins of the Sn-left renal artery and right renal artery (RRA) angled increasingly downward by 21 ± 19° and 13 ± 17°, respectively (P < .005). The F-left renal artery and RRA angled upward by 25 ± 15° and 14 ± 15°, respectively (P < .005). From the pre- to the postoperative period, the end-stent angle of the Sn-RRA increased by 17 ± 12° (P < .00001), with greater magnitude change compared to the F-RRA (P < .0005). Peak curvature increased in distal Sn-RRAs by .02 ± .03 mm(-1) (P < .05). Acute renal failure occurred in 12.5% of patients, although none required dialysis following either F- and Sn-EVAR. Renal stent patency was 97.2% at mean follow-up of 13.7 months. Three type IA endoleaks were identified, prompting one secondary procedure, with the remainder resolving at 6-month follow-up. One renal artery reintervention was performed due to a compressed left renal stent in an asymptomatic patient. CONCLUSIONS: Stented renal arteries were angled more inferiorly after Sn-EVAR and more superiorly after F-EVAR due to stent configuration. Sn-EVAR induced significantly greater angle change at the stent end and curvature change distal to the stent compared to F-EVAR, although no difference in patency was noted in this small series with relatively short follow-up. Sn-RRAs exhibited greater end-stent angle change from the pre- to the postoperative period as compared to the F-RRA. These differences may exert differential effects on long-term renal artery patency, integrity, and renal function following complex EVAR for juxta- or pararenal abdominal aortic aneurysms.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Arteria Renal/cirugía , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Imagenología Tridimensional , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Interpretación de Imagen Radiográfica Asistida por Computador , Arteria Renal/diagnóstico por imagen , Arteria Renal/fisiopatología , Circulación Renal , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Grado de Desobstrucción Vascular
19.
Ann Vasc Surg ; 34: 250-60, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27116907

RESUMEN

BACKGROUND: Visceral arteries are commonly involved in endovascular repair of complex abdominal aortic aneurysms (AAAs). To improve repair techniques and reduce long-term complications involving visceral arteries, it is crucial to understand in vivo arterial geometry and the deformations due to visceral organ movement with respiration. This study quantifies deformation of the celiac, superior mesenteric (SMA), and renal arteries during respiration and correlates the deformations with diaphragmatic excursion. METHODS: Sixteen patients with small AAAs underwent magnetic resonance angiography during inspiratory and expiratory breathholds. From geometric models of the aorta and visceral arteries, vessel length, branch angle, curvature, and positions were computed, along with degree of diaphragmatic excursion as indicated by kidney translation. RESULTS: From inspiration to expiration, the celiac artery exhibited axial shortening of 4.8 ± 6.4% (P < 0.001) and a mean curvature increase of 0.03 ± 0.02 mm(-1), greater than other visceral arteries (P < 0.01). With expiration, the SMA, left and right renal arteries (LRA and RRA) angled upward by -9.8 ± 6.4°, -6.4 ± 6.4°, and -5.2 ± 5.0°, respectively (P < 0.005). All vessels translated superiorly (P < 0.0005) and posteriorly (P < 0.01), and the SMA translated rightward additionally (P < 0.005). The left and right kidneys translated by 22 ± 9 mm and 21 ± 9 mm, mostly superiorly (P < 0.001). Translations of all visceral arteries were moderately correlated to the right kidney (R > 0.50). Correlation of the LRA with the left kidney was greater than that of the RRA with the right kidney. CONCLUSIONS: The celiac artery exhibited less branch angle change, and greater axial and curvature deformations than the other visceral arteries, due to the vicinity to the liver and influence of the median arcuate ligament. Correlation between visceral arteries and kidney translations revealed that diaphragmatic excursion affects vessel mobility. Weaker correlation of the RRA to the right kidney indicates mechanical shielding from the inferior vena cava.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Arteria Celíaca/diagnóstico por imagen , Imagenología Tridimensional , Riñón/diagnóstico por imagen , Angiografía por Resonancia Magnética , Arteria Mesentérica Superior/diagnóstico por imagen , Modelos Cardiovasculares , Arteria Renal/diagnóstico por imagen , Respiración , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/fisiopatología , Contencion de la Respiración , Espiración , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Inhalación , Masculino , Movimiento , Valor Predictivo de las Pruebas
20.
J Vasc Surg ; 61(4): 875-84, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25601499

RESUMEN

OBJECTIVE: This study quantified the geometry and respiration-induced deformation of abdominal branch vessels and stents after fenestrated (F-) and snorkel (Sn-) endovascular aneurysm repair (EVAR). METHODS: Twenty patients (80% male; mean age, 75.2 ± 7.4 years; mean aneurysm diameter, 6.2 ± 1.8 cm) underwent computed tomography angiography during inspiratory and expiratory breath hold protocols after F-EVAR (n = 11) or Sn-EVAR (n = 9). Centerlines for the aorta and visceral vessels were extracted from three-dimensional models. Branch angles were computed relative to the orthogonal plane at the branch ostia, and end-stent angles of the left renal artery (LRA) and right renal artery (RRA) were computed relative to the distal stent orientation. The radius of peak curvature was defined by the circumscribed circle at the highest curvature. RESULTS: Sn-renal branches were more downward-angled than F-renal branches (P < .04). At the distal ends of the RRA stents, Sn-RRAs were angled greater than F-RRAs (P < .03) and had a smaller radius of peak curvature (P < .03). With expiration, the end-stent angle of Sn-LRAs increased by 4° ± 4° (P < .02) and exhibited a significant reduction of radius of curvature (P < .04). The unstented celiac arteries were more downward-angled (P < .02, inspiration), with a smaller radius of curvature (P < .00001), than the unstented superior mesenteric arteries. With expiration, the celiac arteries angled upwards by 9° ± 9° (P < .0005), which was greater than the superior mesenteric arteries (P < .03). At a median postoperative follow-up of 12.6 months (range, 1.0-37.1 months), branch vessel patency was 100%, serum creatinine levels remained stable, and one reintervention was required for a type III endoleak at the main body-LRA stent interface. CONCLUSIONS: Sn-renals were angled more inferiorly at the branch and more angulated at the stent end than F-renals due to stent placement strategies. Sn-LRAs exhibited a significant change in end-stent angle and curvature during respiration, a finding that may compromise long-term durability for parallel stent graft configurations. Further investigation is warranted to better optimize anatomic, patient, and branch vessel stent selection between fenestrated and snorkel strategies and their relationship to long-term patency.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Respiración , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico , Aneurisma de la Aorta Abdominal/fisiopatología , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Arteria Renal/fisiopatología , Arteria Renal/cirugía , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA