Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; : e14403, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38952067

RESUMEN

PURPOSE: This study aimed to clarify the dosimetric impact of the respiratory motion of the liver on stereotactic body radiation therapy (SBRT) for spine metastasis and examine the utility of introducing beam avoidance (beam-off at specific gantry angles). METHODS: A total of 112 consecutive patients who underwent SBRT for spine metastasis between 2018 and 2024 were examined. Overall, 15 patients who had lesions near the liver dome were included in this study. Retrospective treatment plans were generated using computed tomography (CT) images acquired during inhalation and exhalation to evaluate the dosimetric impact of respiratory motion of the liver. The dose difference (DD) and relative value (DD%) were evaluated using the dose-volume histogram (DVH) metrics, planning target volume Dmax, D95%, spinal cord D0.035 cc, and esophagus D2.5 cc. The magnitude of the liver movements was evaluated based on differences of liver size Lave at the isocentric axial plane between the inspiratory and expiratory CT images. RESULTS: The DD in almost all DVH metrics tended to increase when the liver moved away from the target during inhalation: For example, Mean ± $ \pm $ a standard deviation (SD) DD in PTV D95% for the treatment plan incorporating beam avoidance and those without beam avoidance was 0.5 ± $\pm$ 0.3 and 0.9 ± $ \pm $ 0.6 Gy, respectively. The spinal cord D0.035 cc for those shows 0.4 ± $ \pm $ 0.2 and 0.7 ± $ \pm $ 0.7 Gy, respectively. The treatment plans without beam avoidance also showed moderate or strong correlations between Lave and DD for almost all DVH metrics. No correlation was seen in the beam avoidance plan. The spinal cord D0.035 cc revealed approximately 1 Gy or +4% in DD when Lave was < -4 cm. CONCLUSIONS: Respiratory motion of the liver dome can cause substantial dosimetric discrepancies in the dose delivered to the spinal cord, although the extent depends on patient variables. Dose assessment should be performed for determining the appropriate means of respiratory management, such as breath-hold. Alternatively, beam avoidance effectively mitigates the impact.

2.
Jpn J Clin Oncol ; 53(1): 85-90, 2023 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-36239100

RESUMEN

Currently, tongue cancers are primarily managed by surgery, and interstitial brachytherapy is only recommended for a selected group of early state T1-2N0 patients who refuse surgery or are medically inoperable. In this report, a case with T3N2cM0 tongue cancer who has been effectively treated by the combination of concurrent chemoradiotherapy involving volumetric arc therapy and boost high-dose rate interstitial brachytherapy is presented. Of course, surgery remains the main treatment strategy for tongue cancer patients; however, the authors believe that if volumetric arc therapy is carefully planned to reduce the mandible dose as much as possible and high-dose rate interstitial brachytherapy with a mouthpiece that protects the mandible is combined, it is possible to treat T3N2 disease, and this can be considered for patients who want to preserve organ function.


Asunto(s)
Braquiterapia , Neoplasias de la Lengua , Humanos , Braquiterapia/efectos adversos , Neoplasias de la Lengua/radioterapia , Dosificación Radioterapéutica , Cabeza , Quimioradioterapia
3.
J Appl Clin Med Phys ; 24(4): e13865, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36573258

RESUMEN

BACKGROUND: The setup of lung shield (LS) in total body irradiation (TBI) with the computed radiography (CR) system is a time-consuming task and has not been quantitatively evaluated. The TBI mobile imager (TBI-MI) can solve this problem through real-time monitoring. Therefore, this study aimed to perform commissioning and performance evaluation of TBI-MI to promote its use in clinical practice. METHODS: The source-axis distance in TBI treatment, TBI-MI (CNERGY TBI, Cablon Medical B.V.), and the LS position were set to 400, 450, and 358 cm, respectively. The evaluation items were as follows: accuracy of image scaling and measured displacement error of LS, image quality (linearity, signal-to-noise ratio, and modulation transfer function) using an EPID QC phantom, optimal thresholding to detect intra-fractional motion in the alert function, and the scatter radiation dose from TBI-MI. RESULTS: The accuracy of image scaling and the difference in measured displacement of the LS was <4 mm in any displacements and directions. The image quality of TBI imager was slightly inferior to the CR image but was visually acceptable in clinical practice. The signal-to-noise ratio was improved at high dose rate. The optimal thresholding value to detect a 10-mm body displacement was determined to be approximately 5.0%. The maximum fraction of scattering radiation to irradiated dose was 1.7% at patient surface. CONCLUSION: MI-TBI can quantitatively evaluate LS displacement with acceptable image quality. Furthermore, real-time monitoring with alert function to detect intrafraction patient displacement can contribute to safe TBI treatment.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Irradiación Corporal Total , Humanos , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos
4.
J Appl Clin Med Phys ; 24(5): e13915, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36934441

RESUMEN

PURPOSE: We measure the dose distribution of gated delivery for different target motions and estimate the gating latency in a magnetic resonance-guided radiotherapy (MRgRT) system. METHOD: The dose distribution accuracy of the gated MRgRT system (MRIdian, Viewray) was investigated using an in-house-developed phantom that was compatible with the magnetic field and gating method. This phantom contains a simulated tumor and a radiochromic film (EBT3, Ashland, Inc.). To investigate the effect of the number of beam switching and target velocity on the dose distribution, two types of target motions were applied. One is that the target was periodically moved at a constant velocity of 5 mm/s with different pause times (0, 1, 3, 10, and 20 s) between the motions. During different pause times, different numbers of beams were switched on/off. The other one is that the target was moved at velocities of 3, 5, 8, and 10 mm/s without any pause (i.e., continuous motion). The gated method was applied to these motions at MRIdian, and the dose distributions in each condition were measured using films. To investigate the relation between target motion and dose distribution in the gating method, we compared the results of the gamma analysis of the calculated and measured dose distributions. Moreover, we analytically estimated the gating latencies from the dose distributions measured using films and the gamma analysis results. RESULTS: The gamma pass rate linearly decreased with increasing beam switching and target velocity. The overall gating latencies of beam-hold and beam-on were 0.51 ± 0.17 and 0.35 ± 0.05 s, respectively. CONCLUSIONS: Film measurements highlighted the factors affecting the treatment accuracy of the gated MRgRT system. Our analytical approach, employing gamma analysis on films, can be used to estimate the overall latency of the gated MRgRT system.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Humanos , Movimiento (Física) , Espectroscopía de Resonancia Magnética , Dosificación Radioterapéutica , Fantasmas de Imagen
5.
Int Arch Allergy Immunol ; 182(1): 32-38, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32932251

RESUMEN

BACKGROUND: Soy isoflavones and their metabolites such as equol have been associated with a reduced risk of hormone-sensitive tumors and metabolic syndromes. However, individual soy isoflavones and equol levels in atopic dermatitis remain uninvestigated. OBJECTIVE: The aim of this study is to compare the levels of urinary daidzein, genistein, and equol between atopic dermatitis patients and normal subjects and to examine the correlation between equol concentration and the severity of clinical symptoms. METHODS: A cross-sectional study was conducted at Akita University Hospital and Aso Iizuka Hospital in Japan. Fifty patients with confirmed atopic dermatitis diagnosis and 67 healthy controls were recruited. Daidzein, genistein, and equol in urine were measured by using a high-performance liquid chromatography-mass spectrometry system. RESULTS: Urinary equol levels were significantly lower in the atopic dermatitis patients than in the healthy controls (p = 0.002). The difference was particularly noticeable in young people (6-19 years, p < 0.001). No correlations were found between urinary equol levels and the severity of clinical symptoms and laboratory data in the atopic dermatitis patients. CONCLUSION: Equol levels in childhood might be involved in the development of atopic dermatitis.


Asunto(s)
Dermatitis Atópica/epidemiología , Dermatitis Atópica/orina , Equol/orina , Factores de Edad , Biomarcadores , Estudios de Casos y Controles , Niño , Estudios Transversales , Dermatitis Atópica/diagnóstico , Dermatitis Atópica/etiología , Susceptibilidad a Enfermedades , Femenino , Genisteína/orina , Humanos , Isoflavonas/orina , Masculino , Prevalencia , Índice de Severidad de la Enfermedad , Glycine max/efectos adversos
6.
Australas J Dermatol ; 61(1): e39-e45, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31424098

RESUMEN

BACKGROUND: Members of the interleukin (IL)-36 family, IL-36α, IL-36ß and IL-36γ, are potent chemoattractive cytokines for neutrophils and eosinophils. IL-36 receptor antagonist (IL-36Ra) inhibits IL-36α, IL-36ß and IL-36γ activity. However, the immunohistological expression of IL-36α, IL-36ß, IL-36γ and IL-36Ra has never been addressed in normal follicles, folliculitis or eosinophilic pustular folliculitis (EPF). METHODS: We performed immunohistochemical staining for IL-36α, IL-36ß, IL-36γ and IL-36Ra using 10 cases of EPF, nine of non-specific folliculitis, 10 normal skin samples and 10 samples of normal follicles adjacent to a sebaceous naevus as a control. Two dermatologists, who were blind to the patient records, evaluated all of the slides. RESULTS: The immunoreactive IL-36α was hardly detected in the follicular epithelium and epidermis in the normal skin, folliculitis or EPF. The expression of IL-36ß, IL-36γ and IL-36Ra was augmented in both folliculitis and EPF compared with that in normal follicles. Negative correlations were detected between IL-36ß and IL-36Ra and between IL-36γ and IL-36Ra in normal follicles; however, these were absent in folliculitis. In contrast to normal follicles and folliculitis, a significant positive correlation between IL-36ß/γ and IL-36Ra was shown in EPF. CONCLUSIONS: The overexpression of IL-36ß, IL-36γ and IL-36Ra is an integral part of the inflammatory response of folliculitis and EPF. The coordinated expression of IL-36γ and IL-36Ra may be related to the pathomechanism of EPF.


Asunto(s)
Eosinofilia/metabolismo , Foliculitis/metabolismo , Interleucina-1/metabolismo , Interleucinas/metabolismo , Enfermedades Cutáneas Vesiculoampollosas/metabolismo , Estudios de Casos y Controles , Eosinofilia/etiología , Eosinofilia/patología , Foliculitis/etiología , Foliculitis/patología , Humanos , Enfermedades Cutáneas Vesiculoampollosas/etiología , Enfermedades Cutáneas Vesiculoampollosas/patología , Regulación hacia Arriba
7.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 74(12): 1396-1405, 2018 12.
Artículo en Japonés | MEDLINE | ID: mdl-30568089

RESUMEN

This study aimed to develop and evaluate field shape optimization technique based on dose calculation using daily cone-beam computed tomography (CBCT) to compensate for interfractional anatomic changes in three-dimensional conformal radiation therapy (3D-CRT) for prostate cancer. For each of 10 patients, 9-10 CBCT images were obtained throughout the treatment course. The prostate, seminal vesicles, and rectum were manually contoured in all CBCT images. Subsequently, plan adaptation was performed with a program developed in-house. This program calculates dose distributions on CBCT images and optimizes field shape to minimize rectal dose while keeping the target at the optimal dose coverage (the planning target volume D95% receives 95% of the prescription dose). To evaluate the adaptive planning approach, we re-calculated dose distributions on CBCT images based on the conventional and adaptive plans. For the entire cohort, plan adaptation improved rectal V50 Gy, V60 Gy, V65 Gy, and V70 Gy by -7.71±8.43%, -8.30±8.90%, -7.91±8.51% and -7.03±7.70% on average (±SD), respectively. Our results demonstrate that adaptive planning approach is superior to the conventional planning approach for optimizing dose distribution, and this adaptive approach can optimize field shape in 3 min. The proposed approach can be an effective solution for the problem of interfractional anatomic changes in 3D-CRT for prostate cancer.


Asunto(s)
Neoplasias de la Próstata , Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada de Haz Cónico , Humanos , Masculino , Neoplasias de la Próstata/radioterapia , Dosificación Radioterapéutica
8.
J Biol Chem ; 291(28): 14540-54, 2016 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-27151221

RESUMEN

Creation of an intact skin water barrier, a prerequisite for life on dry land, requires the lipoxygenase-catalyzed oxidation of the essential fatty acid linoleate, which is esterified to the ω-hydroxyl of an epidermis-specific ceramide. Oxidation of the linoleate moiety by lipoxygenases is proposed to facilitate enzymatic cleavage of the ester bond, releasing free ω-hydroxyceramide for covalent binding to protein, thus forming the corneocyte lipid envelope, a key component of the epidermal barrier. Herein, we report the transformations of esterified linoleate proceed beyond the initial steps of oxidation and epoxyalcohol synthesis catalyzed by the consecutive actions of 12R-LOX and epidermal LOX3. The major end product in human and porcine epidermis is a trihydroxy derivative, formed with a specificity that implicates participation of an epoxide hydrolase in converting epoxyalcohol to triol. Of the 16 possible triols arising from hydrolysis of 9,10-epoxy-13-hydroxy-octadecenoates, using LC-MS and chiral analyses, we identify and quantify specifically 9R,10S,13R-trihydroxy-11E-octadecenoate as the single major triol esterified in porcine epidermis and the same isomer with lesser amounts of its 10R diastereomer in human epidermis. The 9R,10S,13R-triol is formed by SN2 hydrolysis of the 9R,10R-epoxy-13R-hydroxy-octadecenoate product of the LOX enzymes, a reaction specificity characteristic of epoxide hydrolase. The high polarity of triol over the primary linoleate products enhances the concept that the oxidations disrupt corneocyte membrane lipids, promoting release of free ω-hydroxyceramide for covalent binding to protein and sealing of the waterproof barrier.


Asunto(s)
Epóxido Hidrolasas/metabolismo , Ácido Linoleico/química , Animales , Epidermis/metabolismo , Humanos , Ácidos Linoleicos/metabolismo , Lipooxigenasa/metabolismo , Porcinos
9.
Allergol Int ; 66(3): 398-403, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28057434

RESUMEN

Atopic dermatitis (AD) is a chronic or chronically relapsing, eczematous, severely pruritic skin disorder mostly associated with IgE elevation and skin barrier dysfunction due to decreased filaggrin expression. The lesional skin of AD exhibits Th2- and Th22-deviated immune reactions that are progressive during disease chronicity. Th2 and Th22 cytokines further deteriorate the skin barrier by inhibiting filaggrin expression. Some IgEs are reactive to self-antigens. The IgE autoreactivity may precipitate the chronicity of AD. Upon activation of the ORAI1 calcium channel, atopic epidermis releases large amounts of thymic stromal lymphopoietin (TSLP), which initiates the Th2 and Th22 immune response. Th2-derived interleukin-31 and TSLP induce an itch sensation. Taken together, TSLP/Th2/Th22 pathway is a promising target for developing new therapeutics for AD. Enhancing filaggrin expression using ligands for the aryl hydrocarbon receptor may also be an adjunctive measure to restore the disrupted barrier function specifically for AD.


Asunto(s)
Alérgenos/inmunología , Autoinmunidad , Dermatitis Atópica/inmunología , Dermatitis Atópica/patología , Inmunoglobulina E/inmunología , Animales , Terapia Combinada , Citocinas/metabolismo , Dermatitis Atópica/metabolismo , Dermatitis Atópica/terapia , Proteínas Filagrina , Antígenos de Histocompatibilidad Clase I/inmunología , Humanos , Mediadores de Inflamación/metabolismo , Subgrupos de Linfocitos T/inmunología , Subgrupos de Linfocitos T/metabolismo , Células Th2/inmunología , Células Th2/metabolismo
10.
Exp Dermatol ; 25(7): 532-6, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26896822

RESUMEN

Leukotriene B4 (LTB4 ) receptor type 2 (BLT2) is a novel G-protein-coupled receptor, which selectively binds to 12(S)-hydroxyheptadeca-5Z,8E,10E-trienoic acid (12-HHT) with stronger affinity than to LTB4 . Recently, 12-HHT has been shown to have a protective effect on the epidermal barrier in human keratinocytes or transfectant cells overexpressing BLT2. Because the protective activity of BLT2 in high-calcium conditions, which occurs in well-differentiated cells, is exerted through increasing the integrity of tight junctions, we investigated the effects of 12-HHT on the barrier function of human keratinocytes in low-calcium conditions that mimic the basal layer; to our knowledge, this has not been reported previously. After stimulation with or without 12-HHT, barrier function was measured using transepithelial electrical resistance (TER) and dextran permeability assay. Expression levels of adhesion molecules and actin polymerization were also evaluated. Treatment with 12-HHT increased TER, along with decreased epidermal permeability of dextran in human keratinocytes. Furthermore, 12-HHT induced actin polymerization with phosphorylation of myosin phosphatase target subunit 1. These results suggest that the ligation of BLT2 protects permeability barrier function by enhancing cell-cell contact, even under low-calcium conditions, and indicate that a BLT2 agonist could be a novel therapeutic target for barrier-disrupted skin diseases.


Asunto(s)
Actinas/metabolismo , Ácidos Grasos Insaturados/metabolismo , Queratinocitos/metabolismo , Fosfatasa de Miosina de Cadena Ligera/metabolismo , Receptores de Leucotrieno B4/metabolismo , Línea Celular , Dextranos , Fluoresceína-5-Isotiocianato/análogos & derivados , Humanos , Fosforilación , Polimerizacion , Receptores de Leucotrieno B4/agonistas
12.
Brachytherapy ; 23(1): 45-51, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38040606

RESUMEN

BACKGROUND: Despite its efficacy, if adherence to dose constraints for surrounding normal tissues proves unattainable, the risk of late radiation-related adverse events after primary radiotherapy involving brachytherapy remains a noteworthy concern. Some studies suggest that similar to prostate radiotherapy, spacers may potentially reduce doses to surrounding healthy rectal or bladder tissues. However, guidance on spacer injections for gynecologic brachytherapy is scarce, and the optimal anatomical location for spacer placement remains undefined. We discuss maximizing the effects of spacers from an anatomical perspective. FINDINGS: As vesicovaginal and rectovaginal septa form part of the endopelvic fascia and are not uniform tissues, spacer injection resistance varies. In pelvic organ prolapse surgery, saline is injected into the anterior and posterior vaginal walls as a spacer, and the vagina, vesicovaginal septum, and bladder can be fluidly dissected. Relatively firm vesicovaginal septum tissue is used as a reconstructive organ, whereas rectovaginal septum tissue is less dense. Cervical cancer is invasive, involving surrounding fascia and ligaments. Ideally, the vesicovaginal and rectovaginal septa should be resected in radical hysterectomy. Here, spacer adaptation and the technical details of injection are described. When using ultrasound guidance for spacer injection, the target site should be adequately magnified, and the spacer ideally injected into the incision layer during radical hysterectomy. Finally, posthysterectomy, the intestinal tract may adhere to the vaginal cuffs. Therefore, artificial ascites may be useful; however, the spread depends on perioperative manipulation. CONCLUSIONS: Anatomical and surgical viewpoints are advantageous for safe, therapeutic, and replicable spacer injection administration.


Asunto(s)
Braquiterapia , Masculino , Humanos , Femenino , Braquiterapia/métodos , Recto , Vagina , Inyecciones , Pelvis
13.
Med Dosim ; 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38368182

RESUMEN

Previous plan competitions have largely focused on dose metric assessments. However, whether the submitted plans were realistic and reasonable from a quality assurance (QA) perspective remains unclear. This study aimed to investigate the relationship between aperture-based plan complexity metrics (PCM) in volumetric modulated arc therapy (VMAT) competition plans and clinical treatment plans verified through patient-specific QA (PSQA). In addition, the association of PCMs with plan quality was examined. A head and neck (HN) plan competition was held for Japanese institutions from June 2019 to July 2019, in which 210 competition plans were submitted. Dose distribution quality was quantified based on dose-volume histogram (DVH) metrics by calculating the dose distribution plan score (DDPS). Differences in PCMs between the two VMAT treatment plan groups (HN plan competitions held in Japan and clinically accepted HN VMAT plans through PSQA) were investigated. The mean (± standard deviation) DDPS for the 98 HN competition plans was 158.5 ± 20.6 (maximum DDPS: 200). DDPS showed a weak correlation with PCMs with a maximum r of 0.45 for monitor unit (MU); its correlation with some PCMs was "very weak." Significant differences were found in some PCMs between plans with the highest 20% DDPSs and the remaining plans. The clinical VMAT and competition plans revealed similar distributions for some PCMs. Deviations in PCMs for the two groups were comparable, indicating considerable variability among planners regarding planning skills. The plan complexity for HN VMAT competition plans increased for high-quality plans, as shown by the dose distribution. Direct comparison of PCMs between competition plans and clinically accepted plans showed that the submitted HN VMAT competition plans were realistic and reasonable from the QA perspective. This evaluation may provide a set of criteria for evaluating plan quality in plan competitions.

14.
Imaging Sci Dent ; 54(2): 129-137, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38948189

RESUMEN

Purpose: Patients with head and neck cancer (HNC) who undergo dental procedures during radiotherapy (RT) face an increased risk of developing osteoradionecrosis (ORN). Accordingly, new tools must be developed to extract critical information regarding the dose delivered to the teeth and mandible. This article proposes a novel approach for visualizing 3-dimensional planned dose distributions on panoramic reconstruction computed tomography (pCT) images. Materials and Methods: Four patients with HNC who underwent volumetric modulated arc therapy were included. One patient experienced ORN and required the extraction of teeth after RT. In the study approach, the dental arch curve (DAC) was defined using an open-source platform. Subsequently, pCT images and dose distributions were generated based on the new coordinate system. All teeth and mandibles were delineated on both the original CT and pCT images. To evaluate the consistency of dose metrics, the Mann-Whitney U test and Student t-test were employed. Results: A total of 61 teeth and 4 mandibles were evaluated. The correlation coefficient between the 2 methods was 0.999, and no statistically significant difference was observed (P>0.05). This method facilitated a straightforward and intuitive understanding of the delivered dose. In 1 patient, ORN corresponded to the region of the root and the gum receiving a high dosage (approximately 70 Gy). Conclusion: The proposed method particularly benefits dentists involved in the management of patients with HNC. It enables the visualization of a 3-dimensional dose distribution in the teeth and mandible on pCT, enhancing the understanding of the dose delivered during RT.

15.
Asian J Urol ; 11(2): 286-293, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38680582

RESUMEN

Objectives: Hydrogel spacer (HS) was developed to reduce rectal toxicities caused by radiotherapy, but has been reported to cause major adverse events. Our institute has attempted to introduce a hyaluronic acid (HA) as an alternative spacer. This study aimed to compare rectal doses and geometric distributions between the HS and HA implantation in prostate cancer. Methods: HS and HA were inserted in 20 and 18 patients undergoing high-dose brachytherapy, respectively. The rectum spacer volumes injected were 10 mL and 22 mL, respectively. In the treatment planning system, 13.5 Gy was administered with common catheter positions. The rectal dose indices were assessed between the spacer groups for dosimetry evaluation. Distances between the prostate and rectum and configurations of the spacers were compared. Results: The mean doses irradiated to 0.1 and 2 mL of the rectum were 10.45 Gy and 6.71 Gy for HS, and 6.73 Gy and 4.90 Gy for HA (p<0.001). The mean minimum distances between the prostate and rectum were 1.23 cm and 1.79 cm for HS and HA, respectively (p<0.05). Geometrical configuration comparisons revealed that HA has a higher ability to expand the space than HS. Conclusion: The rectal dose reduction ability of HA is significantly greater than that of HS, suggesting its potential as a new spacer.

16.
Med Phys ; 51(5): 3658-3664, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38507277

RESUMEN

BACKGROUND: Failure mode and effects analysis (FMEA), which is an effective tool for error prevention, has garnered considerable attention in radiotherapy. FMEA can be performed individually, by a group or committee, and online. PURPOSE: To meet the needs of FMEA for various purposes and improve its accessibility, we developed a simple, self-contained, and versatile web-based FMEA risk analysis worksheet. METHODS: We developed an FMEA worksheet using Google products, such as Google Sheets, Google Forms, and Google Apps Script. The main sheet was created in Google Sheets and contained elements necessary for performing FMEA by a single person. Automated tasks were implemented using Apps Script to facilitate multiperson FMEA; these functions were built into buttons located on the main sheet. RESULTS: The usability of the FMEA worksheet was tested in several situations. The worksheet was feasible for individual, multiperson, seminar, meeting, and online purposes. Simultaneous online editing, automated survey form creation, automatic analysis, and the ability to respond to the form from multiple devices, including mobile phones, were particularly useful for online and multiperson FMEA. Automation enabled through Google Apps Script reduced the FMEA workload. CONCLUSIONS: The FMEA worksheet is versatile and has a seamless workflow that promotes collaborative work for safety.


Asunto(s)
Análisis de Modo y Efecto de Fallas en la Atención de la Salud , Japón , Humanos , Física Sanitaria , Internet , Universidades , Pueblos del Este de Asia
17.
Sci Rep ; 14(1): 11253, 2024 05 16.
Artículo en Inglés | MEDLINE | ID: mdl-38755333

RESUMEN

Accelerator-based boron neutron capture therapy (BNCT) systems employing a solid-state lithium target indicated the reduction of neutron flux over the lifetime of a target, and its reduction could represent the neutron flux model. This study proposes a novel compensatory approach for delivering the required neutron fluence and validates its clinical applicability. The proposed approach relies on the neutron flux model and the cumulative sum of real-time measurements of proton charges. The accuracy of delivering the required neutron fluence for BNCT using the proposed approach was examined in five Li targets. With the proposed approach, the required neutron fluence could be delivered within 3.0%, and within 1.0% in most cases. However, those without using the proposed approach exceeded 3.0% in some cases. The proposed approach can consider the neutron flux reduction adequately and decrease the effect of uncertainty in neutron measurements. Therefore, the proposed approach can improve the accuracy of delivering the required fluence for BNCT even if a neutron flux reduction is expected during treatment and over the lifetime of the Li target. Additionally, by adequately revising the approach, it may apply to other type of BNCT systems employing a Li target, furthering research in this direction.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Litio , Neutrones , Terapia por Captura de Neutrón de Boro/métodos , Litio/química , Humanos , Aceleradores de Partículas , Dosificación Radioterapéutica
19.
J Dermatol Sci ; 112(1): 6-14, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37640566

RESUMEN

BACKGROUND: Bullous pemphigoid (BP) is an autoimmune bullous disease in which abundant eosinophils accumulate in the blisters. Galectin-10 abounds in the cytoplasm of eosinophils and is released as a result of eosinophil extracellular trap cell death (EETosis). OBJECTIVE: To identify EETosis and the pathological roles of galectin-10 in BP. METHODS: EETosis and galectin-10 in BP blisters were confirmed by immunofluorescence and transmission electron microscopy. The concentrations of galectin-10 in serum and blister fluid from BP patients were studied by ELISA. The matrix metalloproteinase (MMP) expression in BP blisters was immunohistochemically compared to that in healthy controls. As an in vitro assay, normal human epidermal keratinocytes (NHEKs) and normal human dermal fibroblasts (NHDFs) were stimulated with galectin-10, followed by MMP expression measurement by real-time PCR and ELISA. The signaling pathways activated by galectin-10 were studied using Western blotting and confirmed by inhibition assays. RESULTS: Galectin-10-containing eosinophil infiltration and the extracellular deposition of major basic protein were observed in BP blisters. The ultrastructural characteristics of tissue eosinophils indicated piecemeal degranulation and EETosis. In the BP patients, the concentration of galectin-10 was higher in the blister fluid than in the serum. Several types of MMPs were upregulated in BP blisters. Galectin-10 upregulated the production of MMPs through the pathways of p38 MAPK, ERK and JNK in NHEKs and NHDFs. CONCLUSION: In the BP blisters, the eosinophils underwent EETosis and released galectin-10. Galectin-10 might contribute to BP blister formation through the production of MMPs by keratinocytes and fibroblasts.


Asunto(s)
Vesícula , Penfigoide Ampolloso , Humanos , Vesícula/patología , Eosinófilos , Metaloproteinasas de la Matriz , Galectinas
20.
J Radiat Res ; 64(1): 186-194, 2023 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-36316958

RESUMEN

This study aimed to clarify the differences in radiotherapy dose characteristics and delivery efficiency between the supine and prone positions in patients with prostate cancer using the CyberKnife. The planning computed tomography (CT) and delineations of the prone position were obtained by rotating the supine CT images with delineations of 180° using image processing software. The optimization parameters for planning target volume (PTV) and organs at risk (OARs) were based on the prone position. The optimization parameters determined for the prone position were applied to the supine position for optimization and dose calculation. The dosimetric characteristics of the PTV and OARs, and delivery efficiency were compared between the two different patient positions. The plans in the prone position resulted in better PTV conformity index (nCI), rectum V90%, V80%, V75%, V50% and bladder V50%. A significant difference was observed in treatment time and depth along the central axis (dCAX) between the two plans. The mean treatment time per fraction and dCAX for the supine and prone positions were 20.9 ± 1.7 min versus 19.8 ± 1.3 min (P = 0.019) and 151.1 ± 33.6 mm versus 233.2 ± 8.8 mm (P < 0.001), respectively. In this study the prone position was found to improve dosimetric characteristics and delivery efficiency compared with the supine position during prostate cancer treatment with the CyberKnife.


Asunto(s)
Neoplasias de la Próstata , Radiocirugia , Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Masculino , Humanos , Próstata , Radioterapia Conformacional/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Posición Supina , Dosificación Radioterapéutica , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Órganos en Riesgo , Posición Prona
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA