Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Foot Ankle Surg ; 63(1): 92-96, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37709189

RESUMEN

The objective of this cadaveric biomechanical study was to evaluate if the center-center surgical technique is a reliable and repeatable method of achieving proper syndesmotic reduction when using dynamic syndesmotic fixation. Nine fresh frozen above-knee cadaveric lower extremities were used. Computerized tomography (CT) scans were first obtained for each intact specimen as the baseline for comparison. A simulated complete syndesmotic disruption was created by transection of all deltoid and syndesmotic ligaments. Instability of the ankle was confirmed with stress imaging using fluoroscopy. Each unstable specimen was repaired using the center-center surgical technique with dynamic syndesmosis fixation. A series of measurements from the axial CT images of intact and repaired specimens were used to determine the anatomic distal tibiofibular relationships for comparison of changes from intact to postfixation. All radiographic measurements were performed by 4 independent foot and ankle surgeons. The level of inter-rater reliability for all the measurements was found to be "moderate" to "excellent" agreement (ICC value: 0.865-0.983, 95% confidence interval: 0.634-0.996). There was no statistical difference found between rotational alignment of native and postfixation (a/b: p = .843; b-a: p = .125; θ: p = .062). There was a statistical difference detected for lateral alignment at the center of fibularis incisura between native and postfixation (average: -0.6 ± 0.8 mm, range: -2.3 to 1.2 mm, p < .001). There was no statistical difference found for the anteroposterior translation alignment between native and postfixation (d/e: p = .251; f: p = .377). This study demonstrated the use of the center-center surgical technique as a viable and repeatable method for achieving anatomical reduction of the tibiofibular syndesmosis when used with dynamic fixation modalities.


Asunto(s)
Traumatismos del Tobillo , Peroné , Humanos , Proyectos Piloto , Peroné/cirugía , Reproducibilidad de los Resultados , Traumatismos del Tobillo/diagnóstico por imagen , Traumatismos del Tobillo/cirugía , Articulación del Tobillo/diagnóstico por imagen , Articulación del Tobillo/cirugía , Cadáver
2.
J Hand Surg Am ; 2023 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-37294240

RESUMEN

PURPOSE: The purpose of this study was to biomechanically evaluate the stability of the 6.5 mm intramedullary (IM) olecranon screw compared to locking compression plate fixation for Orthopedic Trauma Association/AO Foundation (OTA/AO) 2U1B1 olecranon fractures under cyclic range of motion of the elbow. METHODS: Twenty paired elbows were randomized to either IM olecranon screw or locking compression plate fixation of a simulated OTA/AO 2U1B1 fracture. Pullout strength was tested by increasing force applied to the triceps and proximal fragment. Fracture gap displacement was measured using differential variable reluctance transducers as the elbow was cycled through a 135° arc of motion using a servohydraulic testing system. RESULTS: Analysis of variance revealed significant interaction between group and load on fracture distraction after the 500th cycle in three settings: between the plate at 5-pound load and screw at 35-pound load, the screw at 5-pound load and screw at 35-pound load, and between the plate at 15-pound load and screw at 35-pound load. The difference in the rate of failure between plate (2 of 80 samples) and screw (4 of 80 samples) was not statistically significant. CONCLUSIONS: For OTA/AO 2U1B1 olecranon fractures, a single 6.5 mm IM olecranon screw demonstrated similar stability when compared to the locking compression plates throughout range of motion testing. CLINICAL RELEVANCE: From a biomechanical perspective, 6.5 mm IM screws and locking compression plates have similar ability to maintain fracture reduction following simulated elbow range of motion exercises in OTA/AO 2U1B1 fractures, giving surgeons another option in the management of these fractures.

3.
J Hand Surg Am ; 48(2): 141-148, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35277301

RESUMEN

PURPOSE: Table saws are commonly used woodworking tools that carry a substantial risk of injury. Blade-stopping technology has been developed and has the potential to reduce the frequency and severity of injury. This study aimed to evaluate this technology on human tissue and characterize the resulting injuries. METHODS: Twenty-seven fresh, frozen cadaveric specimen hands were used. Three scenarios were tested, with the specimen (1) moving forward ("forward"); (2) moving backward, such as in a kickback scenario ("reverse"); and (3) dropped from above the saw blade ("top"). Each scenario was tested at both slow (0.001 m/sec) and fast (forward: 0.6 m/sec; reverse: 0.5 m/sec; top: 2.4 m/sec) approach speeds. The severity of the injuries was characterized by anatomic evaluation and confirmed with radiographic evaluation. Injuries were classified as no laceration, superficial soft tissue injury, deep soft tissue injury, and bony injury. RESULTS: For the slow approach speed, the brake cartridge engaged in 100% of the trials for all 3 scenarios, and 100% of the specimens sustained no injuries. Forward testing at a fast approach speed revealed the brake cartridge engaged in 89% of the trials (injuries: 4 superficial, 2 deep, 3 bony). Reverse testing at a fast approach speed revealed the brake cartridge engaged in 11% of trials (injuries: 1 superficial, 8 bony). Top testing at a fast approach speed revealed the brake cartridge engaged in 89% of the trials (injuries: 9 bony). CONCLUSIONS: Modern blade-stopping technology did not prevent all traumatic hand injuries in fast approach speed scenarios, but it reduced the incidence and severity of injuries. The technology was more effective at low approach speed scenarios. CLINICAL RELEVANCE: The findings of this study provide information to help understand the factors that can prevent or reduce the severity of contact injuries (hand, finger, or thumb) for operators of table saws.


Asunto(s)
Amputación Traumática , Traumatismos de la Mano , Traumatismos de los Tejidos Blandos , Humanos , Accidentes de Trabajo , Traumatismos de la Mano/etiología , Amputación Traumática/epidemiología , Cadáver
4.
J Shoulder Elbow Surg ; 32(3): 512-518, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36283564

RESUMEN

BACKGROUND: The use of electrocautery to facilitate passage of a suture needle through bone without the aid of a drill or burr is a novel technique that has potential utility in orthopedic procedures, but there is a scarcity of research to support its utility. The specific aims of this cadaveric biomechanical study were to evaluate (1) the axial force reduction during suture passage using electrocautery when applied to rotator cuff repair, (2) the temperature change caused while using electrocautery, and (3) the failure loads and failure modes of this technique. METHODS: Five matched pairs of fresh frozen humeri were used, classified into 2 groups: with electrocautery on needle (study group) and without electrocautery on needle (control group). Four individual osseous tunnels were made on the greater tuberosity around the insertion of the supraspinatus tendon. Each specimen was sequentially tested in 2 parts: a needle penetration test (part I) to measure the peak axial force and temperature change and a single load-to-failure test (part II) to measure the maximum load to failure as well as the mechanism of failure. A No. 2 FiberWire suture with a straight needle was used. RESULTS: In part I, the mean peak axial force was lower in the study group compared with the control group for all osseous tunnels but was not statistically significant for individual tunnels. However, there was a significant decrease in peak axial force in the study group of 36% compared with the control group overall (P = .033). There was no significant change in temperature of the tunnel site with the use of electrocautery (mean: 0.2 ± 0.3°C, P = .435). In part II, 100% of the samples from each study group experienced bone tunnel failure. Forty percent of the trials in the study group found lower ultimate failure loads compared with the control group (reduction range: 7%-38%). There was no statistically significant difference in the ultimate failure load between either the loop tested or between the 2 study groups (loop 1: P = .352; loop 2: P = .270). CONCLUSION: Suture passage using electrocautery does significantly decrease the peak force needed to pass a needle directly through the greater tuberosity. This technique does not appear to burn the bone or weaken the bone tunnels. This technique may be useful during open rotator cuff repair or shoulder arthroplasty, although clinicians should be cautious when using this technique as its utility depends on bone quality and cortical thickness, and in vivo results may differ.


Asunto(s)
Lesiones del Manguito de los Rotadores , Manguito de los Rotadores , Humanos , Fenómenos Biomecánicos , Cadáver , Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/cirugía , Electrocoagulación , Suturas , Técnicas de Sutura , Anclas para Sutura
5.
J Pediatr Orthop ; 43(10): e816-e822, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37681304

RESUMEN

BACKGROUNDS: The goals of this study were to (1) compare the effect of casting technique on biomechanical function with different casting materials and different cast core diameters, and (2) compare the strength of a cast based on the number of layers in relation to the core diameter. METHODS: Two standardized cylindrical cast model sizes were used to simulate forearm and short leg casts (core diameter: 60 mm, 100 mm) with 2 different casting techniques (non-smoothing vs. smoothing with lamination), utilizing 2 casting materials [fiberglass and Plaster of Paris (POP)]. Each cast was created using 3 different layers (Fiberglass: 2 to 4 layers; POP: 3 to 5 layers). Ultimate load-to-failure and flexural rigidity were analyzed through cyclic 4-point bend testing. RESULTS: The biomechanical comparison between forearm and short leg casts were significantly different regardless of the same number of layers for both casting materials and between 2 casting techniques. Increased cast thickness significantly increased the ultimate load-to-failure and bending strength. An increased core diameter size significantly decreased the cast's ultimate load-to-failure (fiberglass: 50% to 108%; POP: 10% to 93%) and bending strength (fiberglass: 17% to 35%; POP: 37% to 49%). Casting technique with smoothing with lamination technique had a negative biomechanical effect on POP and a minimal effect on fiberglass. CONCLUSION: The number of layers to apply for a cast should be based on the size of the extremity. Smoothing and lamination technique did not significantly improve the cast mechanical behavior. CLINICAL RELEVANCE: The findings of this study provide valuable evidence, analysis, and supplementary knowledge that helps guide physicians in proper casting technique.


Asunto(s)
Moldes Quirúrgicos , Deformidades Congénitas de las Extremidades Inferiores , Humanos , Extremidad Superior , Antebrazo , Sulfato de Calcio
6.
J Foot Ankle Surg ; 62(2): 338-346, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36180364

RESUMEN

Computed tomography (CT) derived patient-specific total ankle arthroplasty (TAA) systems have been utilized for improved accuracy and reproducible implant alignment. The purpose of the present study was to report the overall implant survivorship as well as radiographic analysis of patients who underwent primary TAA utilizing CT-derived patient-specific instrumentation. A retrospective review of medical charts and radiographs were performed on patients who had undergone primary TAA at a single institution in the Midwest region from March 2013 to October 2020. Radiographic analysis included preoperative, initial postoperative, and final follow-up coronal and sagittal tibiotalar alignment as well as periprosthetic radiolucency. A total of 96 patients with a mean follow-up of 3 years (range, 0.3-7.3 years) were included. Implant survivorship was found to be 92% at median follow-up of 3 years. A total of 8 cases (8.3%) required revision/reoperation, with 6 (6.3%) of these reoperations directly related for failure of one of the metallic implant components. There was significant improvement in both coronal and sagittal tibiotalar alignment from preoperative to initial postoperative follow-up (p < .001). At latest postoperative follow-up, there were 88% of TAAs that remained in a neutral alignment following surgery. A total of 10 cases were found to have radiolucency at latest follow-up. In conclusion, the use of CT derived patient-specific TAA showed high implant survivorship with significant improvement of sagittal and coronal tibiotalar alignment. With better implant alignment and position, it potentially reduces the risk of early implant failure or implant loosening in long-term follow-up.


Asunto(s)
Artroplastia de Reemplazo de Tobillo , Prótesis Articulares , Humanos , Tobillo/cirugía , Supervivencia , Artroplastia de Reemplazo de Tobillo/métodos , Tomografía Computarizada por Rayos X , Articulación del Tobillo/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
7.
J Foot Ankle Surg ; 62(1): 45-49, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35459614

RESUMEN

Percutaneous Achilles tendon repairs can be performed with 2 distal fixation techniques: knotless suture anchor repair (KL) or percutaneous end-to-end repair (ETE). There is a paucity of literature comparing the biomechanical strength of these 2 distal fixation techniques. The aim of this study was to compare the strength of KL and ETE repairs using flat-braided suture for mid-substance Achilles tendon rupture during simulated progressive rehabilitation. Nine matched pairs of fresh-frozen below-knee cadaveric extremities were randomly assigned into these 2 repair groups. Each specimen was tested in 2 parts sequentially; Part I simulating passive ankle range of motion (cyclic: 20N-100N), and Part II simulating ambulation in a walking boot (cyclic: 20N-190N). The number of cycles, gap displacement, and the mode of failure were recorded for each repair. Achilles tendon repairs using the percutaneous methods of ETE and KL techniques showed no significant difference in the number of cycles to clinical failure, mean gap displacement, or overall failure rate. During Part I, the survival rate in terms of clinical failure for KL and ETE groups was 8 of 9 repairs and 7 of 9 repairs, respectively. During Part II, all repairs experienced clinical failure in both groups. Five repairs in the KL group experienced suture anchor pull out from the calcaneus, and 3 repairs failed at suture-tendon interface. Four repairs in the ETE group failed due to knot slippage and 5 repairs failed at suture-tendon interface. Both techniques are viable options in treating acute mid-substance Achilles tendon ruptures.


Asunto(s)
Tendón Calcáneo , Traumatismos del Tobillo , Procedimientos de Cirugía Plástica , Traumatismos de los Tendones , Humanos , Tendón Calcáneo/cirugía , Traumatismos del Tobillo/cirugía , Fenómenos Biomecánicos , Cadáver , Rotura/cirugía , Anclas para Sutura , Técnicas de Sutura , Suturas , Traumatismos de los Tendones/cirugía
8.
J Foot Ankle Surg ; 62(3): 543-547, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36697330

RESUMEN

Proximal interphalangeal (PIP) arthrodesis technique utilizing the peg-in-hole arthrodesis was founded to avoid the use of retained internal fixation implants and thereby potentially decrease the concern of hardware complication. The specific aim of this study was to report the complication rates of the modified peg-in-hole arthrodesis technique and the end-to-end arthrodesis with single screw fixation technique for correcting symptomatic hammertoe deformities in lesser digits. This retrospective chart review included patients who underwent surgical hammertoe correction of lesser digits between the dates of January 2012 and December 2019. Patient demographic data and charts were reviewed to evaluate need for revision including screw/pin removal and complications related to corrective surgery. Five hundred ninety-three symptomatic hammertoe deformity cases (443 female, 150 male) were identified, with 113 cases (88 female, 25 male) treated with peg-in-hole arthrodesis technique and 480 cases (355 female, 125 male) treated with end-to-end arthrodesis with a single screw technique. The deformity recurrence rate was not significantly different between the two techniques (peg-in-hole: 10%, end-to-end: 13%, p = .428). There were 97 cases with postoperative complications that required re-operation (peg-in-hole: 7 cases, end-to-end: 90 cases) with the majority detected at <6 months. There was no statistically significant difference in reoperation rate between the peg-in-hole technique and the end-to-end arthrodesis technique reoperated with reasons excluding simple screw removal (p = .068). This study tended to show these two arthrodesis techniques have equivalent risks and similar success in bone healing; however, the peg-in-hole arthrodesis technique offers an advantage that does not result in retained hardware.


Asunto(s)
Tornillos Óseos , Síndrome del Dedo del Pie en Martillo , Humanos , Masculino , Femenino , Estudios Retrospectivos , Artrodesis/métodos , Síndrome del Dedo del Pie en Martillo/cirugía , Reoperación
9.
Emerg Infect Dis ; 28(1): 196-200, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34647864

RESUMEN

We report severe acute respiratory syndrome coronavirus 2 in semen by using quantitative reverse transcription PCR during the late convalescent phase. Virus was associated with adequate humoral and cell-mediated responses, suggesting possible seeding of the immune-privileged testes. We provide longitudinal semen quality data for 6 other men, including 3 who had oligozoospermia.


Asunto(s)
COVID-19 , Oligospermia , Humanos , Masculino , ARN Viral/genética , SARS-CoV-2 , Semen , Análisis de Semen , Esparcimiento de Virus
10.
Am J Physiol Heart Circ Physiol ; 323(5): H983-H995, 2022 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-36206047

RESUMEN

Dilated cardiomyopathy is the leading cause of death in Duchenne muscular dystrophy (DMD), an inherited degenerative disease of the cardiac and skeletal muscle caused by absence of the protein dystrophin. We showed one hallmark of DMD cardiomyopathy is the dysregulation of cardiac gap junction channel protein connexin-43 (Cx43). Proper Cx43 localization and function at the cardiac intercalated disc (ID) is regulated by post-translational phosphorylation of Cx43-carboxy-terminus residues S325/S328/S330 (pS-Cx43). Concurrently, Cx43 traffics along microtubules (MTs) for targeted delivery to the ID. In DMD hearts, absence of dystrophin results in a hyperdensified and disorganized MT cytoskeleton, yet the link with pS-Cx43 remains unaddressed. To gain insight into the relationship between MTs and pS-Cx43, DMD mice (mdx) and pS-Cx43-deficient (mdxS3A) mice were treated with an inhibitor of MT polymerization, colchicine (Colch). Colch treatment protected mdx, not mdxS3A mice, against Cx43 remodeling, improved MT directionality, and enhanced pS-Cx43/tubulin interaction. Likewise, severe arrhythmias were prevented in isoproterenol-stressed mdx, not mdxS3A mice. Furthermore, MT directionality was improved in pS-Cx43-mimicking mdx (mdxS3E). Mdxutr+/- and mdxutr+/-S3A mice, lacking one copy of dystrophin homolog utrophin, displayed enhanced cardiac fibrosis and reduced lifespan compared with mdxutr+/-S3E; and Colch treatment corrected cardiac fibrosis in mdxutr+/- but not mdxutr+/-S3A. Collectively, the data suggest that improved MT directionality reduces Cx43 remodeling and that pS-Cx43 is necessary and sufficient to regulate MT organization, which plays crucial role in correcting cardiac dysfunction in DMD mice. Thus, identification of novel organizational mechanisms acting on pS-Cx43-MT will help develop novel cardioprotective therapies for DMD cardiomyopathy.NEW & NOTEWORTHY We found that colchicine administration to Cx43-phospho-deficient dystrophic mice fails to protect against Cx43 remodeling. Conversely, Cx43-phospho-mimic dystrophic mice display a normalized MT network. We envision a bidirectional regulation whereby correction of the dystrophic MTs leads to correction of Cx43 remodeling, which in turn leads to further correction of the MTs. Our findings suggest a link between phospho-Cx43 and MTs that provides strong foundations for novel therapeutics in DMD cardiomyopathy.


Asunto(s)
Cardiomiopatías , Distrofia Muscular de Duchenne , Ratones , Animales , Distrofia Muscular de Duchenne/complicaciones , Distrofia Muscular de Duchenne/tratamiento farmacológico , Distrofia Muscular de Duchenne/genética , Distrofina/genética , Conexina 43/genética , Conexina 43/metabolismo , Ratones Endogámicos mdx , Modelos Animales de Enfermedad , Arritmias Cardíacas/genética , Arritmias Cardíacas/prevención & control , Cardiomiopatías/genética , Cardiomiopatías/prevención & control , Microtúbulos/metabolismo , Colchicina , Fibrosis
11.
Brain ; 144(9): 2696-2708, 2021 10 22.
Artículo en Inglés | MEDLINE | ID: mdl-33856027

RESUMEN

Many patients with SARS-CoV-2 infection develop neurological signs and symptoms; although, to date, little evidence exists that primary infection of the brain is a significant contributing factor. We present the clinical, neuropathological and molecular findings of 41 consecutive patients with SARS-CoV-2 infections who died and underwent autopsy in our medical centre. The mean age was 74 years (38-97 years), 27 patients (66%) were male and 34 (83%) were of Hispanic/Latinx ethnicity. Twenty-four patients (59%) were admitted to the intensive care unit. Hospital-associated complications were common, including eight patients (20%) with deep vein thrombosis/pulmonary embolism, seven (17%) with acute kidney injury requiring dialysis and 10 (24%) with positive blood cultures during admission. Eight (20%) patients died within 24 h of hospital admission, while 11 (27%) died more than 4 weeks after hospital admission. Neuropathological examination of 20-30 areas from each brain revealed hypoxic/ischaemic changes in all brains, both global and focal; large and small infarcts, many of which appeared haemorrhagic; and microglial activation with microglial nodules accompanied by neuronophagia, most prominently in the brainstem. We observed sparse T lymphocyte accumulation in either perivascular regions or in the brain parenchyma. Many brains contained atherosclerosis of large arteries and arteriolosclerosis, although none showed evidence of vasculitis. Eighteen patients (44%) exhibited pathologies of neurodegenerative diseases, which was not unexpected given the age range of our patients. We examined multiple fresh frozen and fixed tissues from 28 brains for the presence of viral RNA and protein, using quantitative reverse-transcriptase PCR, RNAscope® and immunocytochemistry with primers, probes and antibodies directed against the spike and nucleocapsid regions. The PCR analysis revealed low to very low, but detectable, viral RNA levels in the majority of brains, although they were far lower than those in the nasal epithelia. RNAscope® and immunocytochemistry failed to detect viral RNA or protein in brains. Our findings indicate that the levels of detectable virus in coronavirus disease 2019 brains are very low and do not correlate with the histopathological alterations. These findings suggest that microglial activation, microglial nodules and neuronophagia, observed in the majority of brains, do not result from direct viral infection of brain parenchyma, but more likely from systemic inflammation, perhaps with synergistic contribution from hypoxia/ischaemia. Further studies are needed to define whether these pathologies, if present in patients who survive coronavirus disease 2019, might contribute to chronic neurological problems.


Asunto(s)
Infarto Encefálico/patología , Encéfalo/patología , COVID-19/patología , Hipoxia-Isquemia Encefálica/patología , Hemorragias Intracraneales/patología , Lesión Renal Aguda/complicaciones , Lesión Renal Aguda/fisiopatología , Lesión Renal Aguda/terapia , Adulto , Anciano , Anciano de 80 o más Años , Bacteriemia/complicaciones , Encéfalo/metabolismo , Infarto Encefálico/complicaciones , COVID-19/complicaciones , COVID-19/fisiopatología , Proteínas de la Nucleocápside de Coronavirus/metabolismo , Femenino , Humanos , Hipoxia-Isquemia Encefálica/complicaciones , Inflamación , Unidades de Cuidados Intensivos , Hemorragias Intracraneales/complicaciones , Masculino , Microglía/patología , Persona de Mediana Edad , Neuronas/patología , Fagocitosis , Fosfoproteínas/metabolismo , Embolia Pulmonar/complicaciones , Embolia Pulmonar/fisiopatología , ARN Viral/metabolismo , Diálisis Renal , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , SARS-CoV-2 , Glicoproteína de la Espiga del Coronavirus/metabolismo , Tasa de Supervivencia , Linfocitos T/patología , Trombosis de la Vena/complicaciones , Trombosis de la Vena/fisiopatología
12.
Mod Pathol ; 33(11): 2147-2155, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32792598

RESUMEN

The novel coronavirus SARS-CoV-2 (coronavirus disease 19, or COVID-19) primarily causes pulmonary injury, but has been implicated to cause hepatic injury, both by serum markers and histologic evaluation. The histologic pattern of injury has not been completely described. Studies quantifying viral load in the liver are lacking. Here we report the clinical and histologic findings related to the liver in 40 patients who died of complications of COVID-19. A subset of liver tissue blocks were subjected to polymerase chain reaction (PCR) for viral ribonucleic acid (RNA). Peak levels of alanine aminotransferase (ALT) and aspartate aminotransferase (AST) were elevated; median ALT peak 68 U/l (normal up to 46 U/l) and median AST peak 102 U/l (normal up to 37 U/l). Macrovesicular steatosis was the most common finding, involving 30 patients (75%). Mild lobular necroinflammation and portal inflammation were present in 20 cases each (50%). Vascular pathology, including sinusoidal microthrombi, was infrequent, seen in six cases (15%). PCR of liver tissue was positive in 11 of 20 patients tested (55%). In conclusion, we found patients dying of COVID-19 had biochemical evidence of hepatitis (of variable severity) and demonstrated histologic findings of macrovesicular steatosis and mild acute hepatitis (lobular necroinflammation) and mild portal inflammation. We also identified viral RNA in a sizeable subset of liver tissue samples.


Asunto(s)
Infecciones por Coronavirus/complicaciones , Hepatopatías/patología , Hepatopatías/virología , Neumonía Viral/complicaciones , Anciano , Anciano de 80 o más Años , Betacoronavirus , COVID-19 , Femenino , Humanos , Masculino , Pandemias , SARS-CoV-2
14.
J Arthroplasty ; 33(9): 2821-2826, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29731267

RESUMEN

BACKGROUND: The impact of prior anterior cruciate ligament (ACL) reconstruction on total knee arthroplasty (TKA) has rarely been studied. The objective of this study was to compare intraoperative characteristics in patients who underwent TKA with pre-existing hardware from prior ACL reconstruction with a matched cohort control group. METHODS: A retrospective study of patients who had undergone primary TKA with pre-existing hardware from prior ACL reconstruction was performed from June 2012 through June 2017. These patients were 2-to-1 matched to the ACL group based on similar patient demographic and provider variables. Outcomes investigated included operative time, estimated blood loss (EBL), and postoperative complications. RESULTS: One hundred one patients met the inclusion/exclusion criteria. The mean age was 54 ± 9 years, and the mean body mass index was 32.6 ± 6.5 kg/m2. The ACL group was divided into 4 subgroups: group 1, no pre-existing hardware removed (22 TKAs); group 2, pre-existing hardware removed from the femur only (8 TKAs); group 3, pre-existing hardware removed from the tibia only (45 TKAs); and group 4, pre-existing hardware removed from both the femur and tibia (26 TKAs). There was no statistical difference in EBL and postoperative complication between the ACL group and controls. Statistical differences were detected between 2 subgroups regarding mean operative time variables: ACL group 3 (74 ± 23 minutes; control: 64 ± 21 minutes, P = .020) and group 4 (79 ± 24 minutes; control: 65 ± 19 minutes, P = .010). CONCLUSION: Hardware retained, especially on the tibia, from prior ACL reconstruction has a major impact on TKA surgical procedure operative time but not on EBL and/or complications.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior/cirugía , Reconstrucción del Ligamento Cruzado Anterior/efectos adversos , Artroplastia de Reemplazo de Rodilla , Adulto , Anciano , Índice de Masa Corporal , Femenino , Fémur/cirugía , Humanos , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Tempo Operativo , Osteoartritis de la Rodilla/cirugía , Complicaciones Posoperatorias/etiología , Periodo Posoperatorio , Estudios Retrospectivos , Factores de Riesgo , Tibia/cirugía
15.
Yale J Biol Med ; 90(2): 283-290, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28656014

RESUMEN

Unlike many of the nontyphoidal Salmonella serovars such as S. Typhimurium that cause restricted gastroenteritis, Salmonella Typhi is unique in that it causes life-threatening typhoid fever in humans. Despite the vast difference in disease outcomes that S. Typhi and S. Typhimurium cause in humans, there are few genomic regions that are unique to S. Typhi. Of these regions, the most notable is the small locus encoding typhoid toxin, an AB toxin that has several distinct characteristics that contribute to S. Typhi's pathogenicity. As a result, typhoid toxin and its role in S. Typhi virulence have been studied in an effort to gain insight into potential treatment and prevention strategies. Given the rise of multidrug-resistant strains, research in this area has become increasingly important. This article discusses the current understanding of typhoid toxin and potential directions for future research endeavors in order to better understand the contribution of typhoid toxin to S. Typhi virulence.


Asunto(s)
Endotoxinas/fisiología , Salmonella typhi/patogenicidad , Fiebre Tifoidea/microbiología , Interacciones Huésped-Patógeno , Humanos , Tropismo Viral/fisiología
16.
Arthroscopy ; 32(7): 1389-99, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27117823

RESUMEN

PURPOSE: To validate basic competency in arthroscopic knot tying using a unique simulator device to compare the level of training needed for learning and tying the arthroscopic knot by evaluating the tensile properties of the arthroscopic knots. METHODS: Three groups of surgeons of various experience levels (postgraduate year [PGY] 1, PGY 3, and experienced surgeons) tied 2 different arthroscopic knots (Tennessee Slider, considered easier, and Weston, considered more difficult) over a 10-week period. Each group went through 3 separate stages of knot tying: stage 1, tying 8 knots without cannula or knot pusher; stage 2, tying 12 knots with knot pusher; and stage 3, tying 20 knots with knot pusher through a cannula that simulates knot tying during surgery. A single load-to-failure test was performed and ultimate clinical failure loads were recorded. Time needed to tie each knot was also recorded. RESULTS: At stages 1 and 2, the PGY 1 group had a significantly weak knot tensile strength (Tennessee Slider stage 1: 60 v 129 N, P = .001; Tennessee Slider stage 2: 69 v 132 N, P = .0029; Weston stage 1: 73 v 184 N, P = .0000; Weston stage 2: 125 v 173 N, P = .0045) and were slower (Weston: 56 v 30 seconds, P = .0010) than the experienced surgeon group for both knots. At stage 3, only the initial 2 weeks of Tennessee Slider showed a significant difference between groups 1 and 3 (week 6: 87 v 118 N, P = .0492; week 7: 89 v 126, P = .01485). Even though the Tennessee Slider knot is one of the easier arthroscopic knots to learn to tie, the results showed a slow trend of improvement in this knot-tying skill for group 1 after each stage. CONCLUSIONS: The data validated an important learning effect in all trainees in arthroscopic knot tying over a 10-week period and showed that inexperienced trainees will be able to improve their knot-tying skill with training in 3 stages with a simulator environment. CLINICAL RELEVANCE: The findings of this study indicated the importance of hands-on experience in performing arthroscopic knot tying, as determined by both knot performance and ultimate suture loop strength. In addition, each orthopaedic resident learned and developed his or her arthroscopic knot-tying skills and provided a foundation for his or her future practice in orthopaedic medicine.


Asunto(s)
Artroscopía/educación , Competencia Clínica , Entrenamiento Simulado , Técnicas de Sutura , Humanos , Internado y Residencia , Resistencia a la Tracción
17.
J Surg Orthop Adv ; 25(2): 74-9, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27518289

RESUMEN

The purpose of this study was to evaluate and compare the intrusion characteristics of Simplex-HV to Simplex-P and Palacos-R in cadaveric proximal tibial bone. Eighteen fresh-frozen cadaver proximal tibiae were examined with standard arthroplasty tibial cuts. Each tibia was randomly assigned to receive one of the three bone cements for use with finger packing technique. Sagittal sections were prepared and analyzed using digital photography and stereoscopic micrographs to evaluate cement intrusion characteristics. The cement penetration depth was measured from the tibial bone cut surface, which did not include the cement thickness under the tibial base plate. Significant differences were detected in the bone cement penetration between the three cements. Penetration was increased using the Simplex-HV (average, 2.7 mm; range, 2.0-3.0 mm) compared with Simplex-P (average, 2.2 mm) and Palacos-R (average, 1.8 mm). These depths approximate to 3.7, 3.2, and 2.8 mm of total cement penetration, respectively. The data suggest that high-viscosity bone cement may provide good fixation of the tibial component of a total knee arthroplasty when using the finger packing technique.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Cementos para Huesos/uso terapéutico , Metilmetacrilato/uso terapéutico , Polimetil Metacrilato/uso terapéutico , Tibia/cirugía , Cadáver , Humanos , Modelos Anatómicos , Fotograbar
18.
J Foot Ankle Surg ; 53(6): 706-11, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24846162

RESUMEN

Syndesmotic injuries of the ankle commonly occur by an external rotation force applied to the ankle joint. Ten fresh-frozen lower extremities from cadavers were used. A specially designed apparatus was used to stabilize the specimen and rotate the ankle joint from internally rotated 25° to externally rotated 35° at a rate of 6°/s for 10 cycles. Two stages were tested (stage I, specimens intact; and stage II, simulated pronation external rotation type injury with fixation). Group 1 was fixed with a novel suture construct across the syndesmotic joint, and group 2 was fixed with a single metallic screw. The torque, rotational angle, and 3-dimensional syndesmotic diastasis readings were recorded. Three-dimensional tibiofibular diastasis was identified. The fibula of the intact specimens displaced an average of 8.6 ± 1.7, 2.4 ± 1.0, and 1.4 ± 1.0 mm in the anterior, lateral, and superior direction, respectively, when the foot was externally rotated 35°. The sectioning of the syndesmostic ligaments and deltoid ligament resulted in a significant decrease in syndesmotic diastasis and foot torsional force (p < .05). The ligament-sectioned specimen lost 57% (externally rotated) and 17% (internally rotated) torsional strength compared with the intact specimen. Groups 1 and 2 provided similar biomechanical stability in this cadaveric model of a syndesmosis deficiency.


Asunto(s)
Traumatismos del Tobillo/cirugía , Articulación del Tobillo/cirugía , Anciano , Traumatismos del Tobillo/fisiopatología , Articulación del Tobillo/fisiopatología , Fenómenos Biomecánicos , Cadáver , Peroné/fisiopatología , Humanos , Persona de Mediana Edad , Modelos Anatómicos , Rotación , Técnicas de Sutura , Tibia/fisiopatología
19.
Iowa Orthop J ; 44(1): 63-68, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38919359

RESUMEN

Background: The specific aim of this study was to evaluate the mechanical properties of cement prepared with the advanced one-step mixing system and whether the addition of vacuum conditions yielded an appreciable improvement in the biomechanical strength or overall quality of bone cement. Methods: The advanced one-step mixing system was used. Twelve specimens were prepared by mixing under vacuum conditions and 12 specimens were prepared by mixing without a vacuum. Radiographs of cement specimens were analyzed to determine the porosity of the test region. Tensile testing of the specimens was performed with a loading rate of 2.54mm/min at room temperature. The ultimate tensile strength (UTS) and the tensile elastic modulus (E) were determined for each sample. Results: The UTS of the bone cement samples mixed under vacuum conditions were not significantly different than those mixed without vacuum (vacuum: 39±6MPa; non-vacuum: 35±6MPa; p=0.637). The E of samples mixed under vacuum conditions was significantly higher than the bone cement mixed without vacuum (vacuum: 2.78±0.06GPa; non-vacuum: 2.63±0.15GPa; p=0.019). Radiographic images showed samples mixed under vacuum conditions contained fewer defects than the samples mixed without vacuum (vacuum: 3.5%±3.3% (range: 0.0%-9.0%); non-vacuum: 6.9%±1.0% (range: 4.6%-8.2%)). Conclusion: Mixing bone cement with the advanced one-step mixing system under vacuum conditions does not produce an appreciable difference in the UTS of the bone cement in a bench biomechanical testing model compared to the bone cement mixed without vacuum. It does, however, create a less porous cement mixture with a higher E compared to cement mixed without vacuum. Level of Evidence: V.


Asunto(s)
Cementos para Huesos , Ensayo de Materiales , Resistencia a la Tracción , Vacio , Polimetil Metacrilato/química , Humanos , Módulo de Elasticidad , Fenómenos Biomecánicos , Porosidad
20.
Kans J Med ; 17: 30-33, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38694181

RESUMEN

Introduction: Traditional mallet broaching and stem seating in cementless total hip arthroplasty (THA) can result in femoral stem misalignment, potentially reducing implant longevity. This study aimed to compare the pullout strength of cementless THA femoral stems with different cross-sectional designs achieved through the powered impactor method versus the traditional mallet method. Methods: The authors utilized 24 polyurethane foam femurs and two femoral bone preservation stems with different proximal cross-sectional shapes (double taper: ACTIS®, size 5; flat taper: TRI-LOCK®, size 5). A single orthopedic surgeon broached each femur from size 0 to size 5 using either the powered impactor or mallet impaction methods. Broaching time and component implantation times were recorded. A load-to-failure pullout strength test was conducted, and the ultimate pullout load was recorded. Results: The broaching time for the TRI-LOCK® stem showed a statistically significant difference between the two impaction methods (powered: 37±7 seconds, mallet: 75±29 seconds, F[3, 20] = 4.56, p = 0.002), but no statistically significant difference was detected for the ACTIS® stem between the two impaction methods (powered: 47±22 seconds, mallet: 59±9 seconds, F[3, 20] = 4.56, p = 0.304). There was a statistically significant difference in pullout strength between the two impaction groups, and this strength was influenced by the implant cross-sectional shape (ACTIS®: 774±75N versus 679±22N, F(3,20) = 16.38, p = 0.018; TRI-LOCK®: 616±57N versus 859±85N, F(3, 20) = 16.38, p <0.001). Conclusions: The technique used for femoral bone preparation (powered impactor versus mallet) and the cross-sectional design of the cementless femoral stem are crucial factors that affect initial stem stability and operation time.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA