Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Acta Radiol ; 59(3): 280-286, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28648124

RESUMEN

Background Knowledge-based iterative model reconstruction (IMR) is known to allow radiation dose reduction while preserving image quality. Purpose To investigate the effect of IMR on coronary computed tomography angiography (CCTA) by comparing it with filtered back projection (FBP) and hybrid iterative reconstruction (HIR). Material and Methods Forty-five patients (group A) who underwent CCTA with prospective electrocardiogram (ECG) triggering at 80 kVp were included. All images were reconstructed using three algorithms: FBP, HIR, and IMR. The control group comprised 45 patients (group B) who underwent CCTA at 100 kVp; their images were reconstructed with HIR alone. Objective and subjective image quality was assessed by two radiologists. Results In group A, the signal-to-noise and contrast-to-noise ratios were significantly higher for images reconstructed with IMR than with HIR or FBP ( P < 0.001). IMR was also superior to HIR and FBP in subjective image quality analyses, including image noise, vessel sharpness, beam-hardening artifact, and overall quality ( P < 0.001). Moreover, the images reconstructed using IMR in group A had superior image quality with less radiation exposure than those reconstructed using HIR in group B on both objective and subjective analyses ( P < 0.001). The mean attenuation values were also significantly higher in group A than in group B ( P < 0.001). Conclusion Compared with HIR and FBP, IMR provided higher quality images with less radiation exposure in CCTA, using low kilovoltage and prospective ECG triggering.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Estudios Retrospectivos
2.
Ann Rheum Dis ; 75(7): 1367-71, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26757749

RESUMEN

OBJECTIVES: The aim is to investigate whether the 12-month quantitative changes in high-resolution CT (HRCT) measures of interstitial lung disease (ILD) are different, and to understand how they change, in patients with scleroderma-related ILD who receive drug therapy versus placebo. METHODS: HRCT images were acquired at baseline and at 12 months in 83 participants in Scleroderma Lung Study I, a clinical trial comparing treatment with oral cyclophosphamide versus placebo. A computer-aided model was used to quantify the extent of fibrotic reticulation, ground glass and honeycomb patterns and quantitative ILD (QILD: sum of these patterns) in the whole lung and the lung zone (upper, middle or lower) of maximal disease involvement. RESULTS: Mean QILD score decreased by 3.9% in the cyclophosphamide group while increasing by 4.2% in the placebo group in the most severe zone (p=0.01) and decreased by 3.2% in the cyclophosphamide group while increasing by 2.2% in the placebo group in the whole lung (p=0.03). Transitional probabilities demonstrated greater changes from a fibrotic to either a ground glass or normal pattern in the cyclophosphamide group and the reverse in the placebo group. CONCLUSIONS: Changes in quantitative HRCT measures of ILD provide a sensitive indication of disease progression and response to treatment. TRIAL REGISTRATION NUMBER: NCT00004563; Post-results.


Asunto(s)
Antirreumáticos/uso terapéutico , Ciclofosfamida/uso terapéutico , Enfermedades Pulmonares Intersticiales/patología , Esclerodermia Sistémica/tratamiento farmacológico , Adulto , Progresión de la Enfermedad , Femenino , Humanos , Pulmón/patología , Enfermedades Pulmonares Intersticiales/etiología , Masculino , Esclerodermia Sistémica/complicaciones , Esclerodermia Sistémica/patología , Resultado del Tratamiento
3.
AJR Am J Roentgenol ; 203(5): W525-32, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25341167

RESUMEN

OBJECTIVE: The objective of our study was to measure thyroid volumes using semiautomated 3D CT and to compare the 3D CT volumes with volumes measured using 2D ultrasound, 2D CT, and the water displacement method. SUBJECTS AND METHODS: In 47 patients, 2D ultrasound volumes and 2D CT volumes of the thyroid gland were estimated using the ellipsoid volume formula, and 3D CT volumes were calculated using semiautomated reconstructive techniques. All volume data were compared with thyroid specimen volumes obtained using the water displacement method and were statistically analyzed using the one-way ANOVA, the Pearson correlation coefficient (R), linear regression, and the concordance correlation coefficient (CCC). The processing time of semiautomated 3D CT thyroid volumetry was measured. RESULTS: The paired mean differences ± SD between the three imaging-determined volumes and the specimen volumes were 0.8 ± 3.1 mL for 2D ultrasound, 4.0 ± 4.7 mL for 2D CT, and 0.2 ± 2.5 mL for 3D CT. A significant difference in the mean thyroid volume was found between 2D CT and specimen volumes (p = 0.016) compared with the other pairs (p = 0.937 for 2D ultrasound mean volume vs specimen mean volume, and p = 0.999 for 3D CT mean volume vs specimen mean volume). Between specimen volume and 2D ultrasound volume, specimen volume and 2D CT volume, and specimen volume and 3D CT volume, R values were 0.885, 0.724, and 0.929, respectively, and CCC values were 0.876, 0.598, and 0.925, respectively. The mean processing time of semiautomated 3D CT thyroid volumetry was 7.0 minutes. CONCLUSION: Thyroid volumes measured using 2D ultrasound or semiautomated 3D CT are substantially close to thyroid specimen volumes measured using the water displacement method. Semiautomated 3D CT thyroid volumetry can provide a more reliable measure of thyroid volume than 2D ultrasound.


Asunto(s)
Antropometría/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Tamaño de los Órganos , Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/fisiopatología , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Inteligencia Artificial , Humanos , Masculino , Persona de Mediana Edad , Reconocimiento de Normas Patrones Automatizadas/métodos , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Ultrasonografía/métodos
4.
Acad Radiol ; 30(2): 258-275, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35491344

RESUMEN

RATIONALE AND OBJECTIVES: This study evaluated the completeness of systematic reviews and meta-analyses in radiology using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses for Diagnostic Test Accuracy (PRISMA-DTA) and PRISMA-DTA for Abstracts guidelines between articles published before and those published after the issuance of the guideline and identify areas that have been poorly reported. MATERIALS AND METHODS: PubMed were searched for systematic reviews on DTA with or without meta-analyses published in general radiology journals between January 1, 2016 and December 31, 2020. The identified articles were assessed for completeness of reporting according to the PRISMA-DTA. Subgroup analyses were performed for association of completeness of reporting with multiple cofactors. RESULTS: The search identified 183 reviews from 12 journals. The mean numbers (standard deviation) of reported PRISMA-DTA and PRISMA-DTA for Abstracts items in the full texts and abstracts were 18.45 (2.02) and 5.66 (1.28), respectively. Subgroup analysis showed that compared to the corresponding reference groups, a higher mean number of reported PRISMA-DTA items was associated with publication during July 2018-December 2020 [(17.82 (2.01) vs 18.89 (1.91); p = 0.034), citation of the PRISMA-DTA [17.62 (1.86) vs 20.27 (2.02); p < 0.001], and inclusion of supplementary materials [17.64 (2) vs 19.09 (1.8); p < 0.001] on multiple-linear regression analysis. CONCLUSION: Completeness of reporting with respect to the PRISMA-DTA and PRISMA-DTA for Abstracts has improved modestly since the publication of the PRISMA-DTA guideline; however, increasing awareness of the specific weakness provides the chance for completeness improvement.


Asunto(s)
Radiología , Humanos , Radiografía , Pruebas Diagnósticas de Rutina
5.
Endocr Res ; 36(4): 149-57, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21973234

RESUMEN

INTRODUCTION: Dexamethasone is known to inhibit the cell proliferation of certain transformed cell lines. In this study, the effect and action mechanism of dexamethasone were examined in the human medullary thyroid cancer cell line, TT cells. METHODS: TT cells were treated with or without dexamethasone. 5-Bromo-2'-deoxyuridine uptake assay was used to evaluate cell proliferation. Cell cycle and its regulatory proteins were assessed by flow cytometry and western blot analysis, respectively. Apoptosis was analyzed by Hoechst staining and Annexin V assay. RESULTS: Dexamethasone significantly reduced TT cell proliferation by 60% (p < 0.01). A substantial portion of cells was arrested at the G1 phase. The expression levels of cyclin D1, cyclin-dependent kinase (CDK)4, and CDK2 were decreased. In addition, the phosphorylation of retinoblastoma protein, which is a critical checkpoint protein in the transition of G1 to S phase, was decreased. On the other hand, the expression level of p27(Kip1), which is a cyclin/CDK inhibitor, was enhanced. Hoechst staining showed many fragmented nuclei in the dexamethasone-treated cells. The proportion of early apoptotic cells was also increased in the Annexin V assay. CONCLUSION: Dexamethasone inhibited the proliferation of TT cells through cell cycle arrest at the G1 phase and increased apoptosis.


Asunto(s)
Carcinoma Medular/tratamiento farmacológico , Dexametasona/farmacología , Glucocorticoides/farmacología , Neoplasias de la Tiroides/tratamiento farmacológico , Apoptosis/efectos de los fármacos , Western Blotting , Carcinoma Medular/metabolismo , Carcinoma Medular/patología , Puntos de Control del Ciclo Celular/efectos de los fármacos , Línea Celular Tumoral , Proliferación Celular/efectos de los fármacos , Ciclina D1/biosíntesis , Quinasa 2 Dependiente de la Ciclina/biosíntesis , Quinasa 4 Dependiente de la Ciclina/biosíntesis , Inhibidor p27 de las Quinasas Dependientes de la Ciclina/biosíntesis , Citometría de Flujo , Humanos , Neoplasias de la Tiroides/metabolismo , Neoplasias de la Tiroides/patología
6.
Breast Cancer Res Treat ; 122(2): 453-7, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20532977

RESUMEN

Sentinel lymph node biopsy with lymphoscintigraphy has become the standard method for the detection of axillary lymph node metastasis in breast cancer patients. However, there is no standardized radiopharmaceutical. For the detection of axillary lymph node metastasis by lymphoscintigraphy and sentinel node biopsy in patients with breast cancer, we compared the results between subareolar injection of (99m)Tc-tin colloid and injection of (99m)Tc-phytate. This study included 516 breast cancer patients who underwent surgery between 2001 and 2010. Among the 516 patients, (99m)Tc-tin colloid (37-185 MBq) was administered to 412 patients by subareolar injection, and (99m)Tc-phytate (37-185 MBq) was injected in 104 patients. Lymphoscintigraphy was performed with the patients in the supine position, and sentinel node identification was performed by hand-held gamma probe during surgery. Among 412 patients with (99m)Tc-tin colloid, the sentinel node was identified by lymphoscintigraphy in 364 cases (88.3%) and by a gamma probe in 369 cases (89.6%). Among 104 patients with (99m)Tc-phytate, 101 cases (97.1%) were identified by lymphoscintigraphy and 101 cases (97.1%) were identified by a gamma probe. The identification rates by lymphoscintigraphy and gamma probe were superior with (99m)Tc-phytate, as compared with (99m)Tc-tin colloid, with a statistically significant difference (P < 0.05 for both methods). (99m)Tc-phytate is a better choice than (99m)Tc-tin colloid for identification of the sentinel node in breast cancer patients.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Ganglios Linfáticos/diagnóstico por imagen , Compuestos de Organotecnecio , Ácido Fítico , Radiofármacos , Biopsia del Ganglio Linfático Centinela/métodos , Compuestos de Tecnecio , Compuestos de Estaño , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/secundario , Femenino , Humanos , Inyecciones , Metástasis Linfática , Persona de Mediana Edad , Compuestos de Organotecnecio/administración & dosificación , Ácido Fítico/administración & dosificación , Valor Predictivo de las Pruebas , Cintigrafía , Radiofármacos/administración & dosificación , República de Corea , Compuestos de Tecnecio/administración & dosificación , Compuestos de Estaño/administración & dosificación , Adulto Joven
7.
PLoS One ; 15(2): e0228609, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32084154

RESUMEN

PURPOSE: To evaluate the image quality of low-dose chest digital radiographic images obtained with a new spatial noise reduction algorithm, compared to a conventional de-noising technique. MATERIALS AND METHODS: In 69 patients, the dose reduction protocol was divided into A, B, and C test groups- 60% (n = 22), 50% (n = 23), and 40% (n = 24) of the baseline dose. In each patient, baseline dose radiographs were obtained with conventional image processing while low-dose images were acquired with new image processing. A set of baseline and low-dose radiographic images per patient was evaluated and scored on a 5-point scale over seven anatomical landmarks (radiolucency of unobscured lung, pulmonary vascularity, trachea, edge of rib, heart border, intervertebral disc space, and pulmonary vessels in the retrocardiac area) and three representative abnormal findings (nodule, consolidation, and interstitial marking) by two thoracic radiologists. A comparison of paired baseline and low-dose images was statistically analyzed using a non-inferiority test based on the paired t-test or the Wilcoxon signed-rank test. RESULTS: In A, B, and C test groups, the mean dose reduction rate of the baseline radiation dose was 63.4%, 53.9%, and 47.8%, respectively. In all test groups, the upper limit of the 95% confidence interval was less than the non-inferiority margin of 0.5 every seven anatomical landmarks and three representative abnormal findings, which suggested that the image quality of the low-dose image was not inferior to that of the baseline dose image even if the maximum average dose reduction rate was reduced to 47.8% of the baseline dose. CONCLUSION: In our study, an image processing technique integrating a new noise reduction algorithm achieved dose reductions of approximately half without compromising image quality for abnormal lung findings and anatomical landmarks seen on chest radiographs. This feature-preserving, noise reduction algorithm adopted in the proposed engine enables a lower radiation dose boundary for the sake of patient's and radiography technologist's radiation safety in routine clinical practice, in compliance with regulatory guidelines.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Dosis de Radiación , Radiografía Torácica/métodos , Adulto , Algoritmos , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/normas , Masculino , Radiografía Torácica/normas , Relación Señal-Ruido
8.
J Clin Ultrasound ; 37(9): 528-30, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19582826

RESUMEN

Killian-Jamieson diverticulum is a rare form of pharyngoesophageal diverticula emerging in the anterolateral wall of the cervical esophagus. We present a case of Killian-Jamieson diverticulum that mimicked a thyroid nodule on sonography (US), and for which a US-guided fine-needle aspiration (FNA) was performed. The possibility of Killian-Jamieson diverticulum should be considered when a thyroid nodule is seen adjacent to the esophagus even without US change during/after swallowing.


Asunto(s)
Divertículo/diagnóstico por imagen , Nódulo Tiroideo/diagnóstico por imagen , Divertículo de Zenker/diagnóstico por imagen , Biopsia con Aguja Fina , Divertículo/cirugía , Humanos , Masculino , Persona de Mediana Edad , Nódulo Tiroideo/diagnóstico , Nódulo Tiroideo/patología , Nódulo Tiroideo/cirugía , Ultrasonografía , Divertículo de Zenker/cirugía
9.
PLoS One ; 14(8): e0220550, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31369602

RESUMEN

PURPOSE: Our purpose was to assess the differences in growth rates of multiple pulmonary metastatic nodules using three-dimensional (3D) computed tomography (CT) volumetry and propose a concept of CT spatial tumor heterogeneity. MATERIALS AND METHODS: We manually measured the largest diameter of metastatic pulmonary nodules on chest CT scans, and calculated the 3D maximum diameter and the volume using a semi-automated 3D CT volumetry of each nodule. The tumor response was assessed according to the revised RECIST 1.1. We defined a nodule as an outlier based on 1.5 times growth during follow-up. The CT spatial tumor heterogeneity was statistically analyzed by the "minimum combination t-test method" devised in our study. RESULTS: On manual measurement, the tumor response category was stable disease (SD) in all 10 patients. Of them, total 155 metastatic nodules (4-52 nodules per patient) were segmented using the 3D CT volumetry. In the 3D maximum diameter, 9 patients had SD except for one patient with partial response in the two selected nodules; for the volume, all 10 patients were SD. For the 3D maximum diameter, six patients had at least one outlier; whereas five patients had the outlier on the volume measurement. Six patients were proven to have overall CT spatial tumor heterogeneity. CONCLUSIONS: The spatial tumor heterogeneity determined in a CT parametric approach could be statistically assessed. In patients with CT spatial heterogeneity, tumors with different growth rates may be neglected when the nodules are assessed according to the current guideline.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Anciano , Tomografía Computarizada de Haz Cónico , Femenino , Humanos , Imagenología Tridimensional , Pulmón/diagnóstico por imagen , Pulmón/patología , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Nódulos Pulmonares Múltiples/patología , Estudios Retrospectivos
10.
PLoS One ; 13(11): e0207959, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30475907

RESUMEN

PURPOSE: To evaluate the feasibility of quantitative analysis of chest computed tomography (CT) scans for the assessment of lymph node (LN) involvement in patients with pulmonary tuberculosis and sarcoidosis. METHODS: In 47 patients with tuberculosis (n = 26) or sarcoidosis (n = 21), 115 lymph nodes (tuberculous, 55; sarcoid, 60) were visually analyzed on chest CT scans according to their size, location, attenuation and shape. Each node was manually segmented using image analysis tool, which was quantitatively analyzed using the following variables: Feret's diameter, perimeter, area, circularity, mean grey value (Mean), standard deviation (SD) of grey value, minimum grey value (Min), maximum grey value (Max), median grey value (Median), skewness, kurtosis, and net enhancement. We statistically analyzed the visual and quantitative CT features of tuberculous and sarcoid LNs. RESULTS: In visual CT analysis, the mean node size in sarcoidosis was significantly greater than that in tuberculosis. There were no statistical differences between tuberculous and sarcoid LNs in terms of location and shape. Central low attenuation and peripheral rim enhancement were more frequently observed in tuberculous LNs than in the sarcoid ones. In quantitative CT analysis, there were significant differences in the values of the Feret's diameter, perimeter, area, circularity, mean grey value, SD, median, skewness, and kurtosis between tuberculous and sarcoid LNs. CONCLUSIONS: Quantitative CT analysis using CT parameters with pixel-by-pixel measurements can help to differentiate of tuberculous and sarcoid LNs.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Ganglios Linfáticos/diagnóstico por imagen , Enfermedades Linfáticas/diagnóstico por imagen , Sarcoidosis Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Tuberculosis/diagnóstico por imagen , Adulto , Anciano , Diagnóstico Diferencial , Estudios de Factibilidad , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tórax/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
11.
Cancer Res Treat ; 50(1): 11-18, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28231691

RESUMEN

PURPOSE: The purpose of this study was to evaluate the diagnostic performance and cost of screening thyroid ultrasonography (US) in an asymptomatic population and determine the US features of screening-detected thyroid cancer. MATERIALS AND METHODS: This study included 1,845 asymptomatic participants who underwent screening thyroid US between March and August 2012 at the screening center in our hospital. We evaluated the diagnostic performance of screening thyroid US for thyroid cancer and the average cost of diagnosis for each patient. We also determined the characteristic US features of screening-detected thyroid cancer. RESULTS: Of the 1,845 subjects, 661 showed no abnormalities, 1,155 exhibited benign thyroid nodules, and 29 exhibited thyroid cancer. Imaging features such as solid composition, hypoechogenicity, taller-than-wide axis, and ill-defined or spiculated margins of nodules were suggestive of malignancy. The rate of detection of cancer was 1.6% (29/1,845), and the sensitivity, specificity, and positive and negative predictive values were 100% (18/18), 98.7% (1,051/1,065), 56.3% (18/32), and 100% (1,051/1,051), respectively. Of 18 patients who underwent thyroidectomy, three (16.7%) had a pathological tumor staging of T3, and four (22.2%) had a pathological nodal staging of N1a. The average cost of diagnosis for each patient with cancer was $7,319. CONCLUSION: Screening thyroid US exhibited a good diagnostic performance, with a feasible social cost of use. This modality demonstrated significant differences in sonographic features between screening-detected cancer and benign nodules.


Asunto(s)
Glándula Tiroides/diagnóstico por imagen , Ultrasonografía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Detección Precoz del Cáncer , Femenino , Humanos , Masculino , Tamizaje Masivo , Persona de Mediana Edad , Estudios Retrospectivos , Ultrasonografía/economía , Adulto Joven
12.
Contemp Clin Trials Commun ; 9: 60-63, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29696225

RESUMEN

BACKGROUND AND PURPOSE: An optimal pulmonary localization technique for video-assisted thoracic surgery (VATS) of small lung nodules has not yet been established. The LOcalization of Ground-glass-opacity and pulmonary lesions for mInimal Surgery (LOGIS) registry aims to establish a multicenter database and investigate the usefulness and safety of localization techniques for small pulmonary lesions in individuals undergoing VATS. METHODS/DESIGN: The LOGIS registry is a large-scale, multicenter cohort study, aiming to enroll 825 patients at 10 institutions. Based on the inclusion and exclusion criteria, all study participants with pulmonary lesions indicated for VATS will be screened and enrolled at each site. All study participants will undergo preoperative lesion localization by the hook-wire or lipiodol localization methods according to site-specific methods. Within a few hours of marking, thoracoscopic surgery will be done under general anesthesia by experienced thoracoscopic surgeons. The primary endpoints are the success and complication rates of the two localization techniques. Secondary endpoints include procedure duration, recurrence rate, and all-cause mortality. Study participant enrollment will be completed within 2 years. Procedure success rates and incidence of complications will be analyzed based on computed tomography findings. Procedure duration, recurrence rate, and all-cause mortality will be compared between the two techniques. The study will require 5 years for completion, including 6 months of preparation, 3.5 years for recruitment, and 1 year of follow-up endpoint assessment. DISCUSSION: The LOGIS registry, once complete, will provide objective comparative results regarding the usefulness and safety of the lipiodol and hook-wire localization techniques.

13.
PLoS One ; 13(2): e0192626, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29420619

RESUMEN

Lung cancer specialists play an important role in designing and implementing lung cancer screening. We aimed to describe their 1) attitudes toward low-dose lung computed tomography (LDCT) screening, 2) current practices and experiences of LDCT screening and 3) attitudes and opinions towards national lung cancer screening program (NLCSP). We conducted a national web-based survey of pulmonologists, thoracic surgeons, medical oncologists, and radiological oncologists who are members of Korean Association for Lung Cancer (N = 183). Almost all respondents agreed that LDCT screening increases early detection (100%), improves survival (95.1%), and gives a good smoking cessation counseling opportunity (88.6%). Most were concerned about its high false positive results (79.8%) and the subsequent negative effects. Less than half were concerned about radiation hazard (37.2%). Overall, most (89.1%) believed that the benefits outweigh the risks and harms. Most (79.2%) stated that they proactively recommend LDCT screening to those who are eligible for the current guidelines, but the screening propensity varied considerably. The majority (77.6%) agreed with the idea of NLCSP and its beneficial effect, but had concerns about the quality control of CT devices (74.9%), quality assurance of radiologic interpretation (63.3%), poor access to LDCT (56.3%), and difficulties in selecting eligible population using self-report history (66.7%). Most (79.2%) thought that program need to be funded by a specialized fund rather than by the National Health Insurance. The opinions on the level of copayment for screening varied. Our findings would be an important source for health policy decision when considering for NLCSP in Korea.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Actitud Frente a la Salud , Femenino , Humanos , Neoplasias Pulmonares/psicología , Masculino , Persona de Mediana Edad , Dosis de Radiación , República de Corea
14.
AJR Am J Roentgenol ; 188(2): W126-34, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17242217

RESUMEN

OBJECTIVE: The purpose of this pictorial essay is to illustrate the radiologic manifestations of pulmonary artery aneurysms and pseudoaneurysms with emphasis on the findings on contrast-enhanced CT. CONCLUSION: Pulmonary artery aneurysms and pseudoaneurysms are uncommon. Most are caused by trauma, often iatrogenic, infection, and Behçet's syndrome. Less common causes include pulmonary hypertension, congenital heart disease, neoplasms, and connective tissue disease. Recognition of pulmonary artery aneurysms and pseudoaneurysms is important because of the high morbidity and mortality rates of rupture.


Asunto(s)
Aneurisma/diagnóstico por imagen , Angiografía/métodos , Arteria Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Aneurisma Falso/diagnóstico por imagen , Humanos , Guías de Práctica Clínica como Asunto , Pautas de la Práctica en Medicina
15.
AJR Am J Roentgenol ; 188(5): 1223-31, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17449764

RESUMEN

OBJECTIVE: The purpose of this study was to describe retrospectively integrated PET/CT findings on pulmonary neuroendocrine tumors and to correlate the findings with prognosis. MATERIALS AND METHODS: Between May 2003 and February 2005, 37 consecutively enrolled patients (33 men and four women; mean age, 60 years) with histopathologically proven pulmonary neuroendocrine tumors underwent 18F-FDG PET/CT after enhanced standalone CT. CT was used to analyze the morphologic features of the tumors and PET to measure maximum standardized uptake value (SUV). Maximum SUVs of carcinoid tumors, large-cell neuroendocrine carcinomas (LCNECs), and small-cell lung carcinomas (SCLCs) were compared, and maximum SUV and tumor stage and prognosis were correlated. RESULTS: Four (two typical and two atypical) of the seven carcinoid tumors had no FDG uptake or less than mediastinal uptake. The maximum SUVs of primary tumors, in increasing order, were significantly different for carcinoids (mean, 4.0; median, 3.4), LCNECs (mean, 12.0; median, 10.7), and SCLCs (mean, 11.6; median, 11.7) (p = 0.006, Kruskal-Wallis test). There was no significant correlation between maximum SUV of the primary tumor and the tumor stages of carcinoids, LCNECs, or SCLCs (p = 0.08, Jonckheere-Terpstra test; p = 0.768, Mann-Whitney test). Results of receiver operating characteristics analysis showed a maximum SUV greater than 13.7 suggested a poor survival period in cases of LCNEC and SCLC. CONCLUSION: The maximum SUVs of neuroendocrine tumors are significantly different for carcinoid tumors, LCNECs, and SCLCs, and a high maximum SUV suggests short survival of patients with LCNEC or SCLC.


Asunto(s)
Neoplasias Pulmonares/diagnóstico , Tumores Neuroendocrinos/diagnóstico , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Adulto , Anciano , Femenino , Fluorodesoxiglucosa F18 , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Pronóstico , Radiofármacos , Estudios Retrospectivos
16.
J Thorac Dis ; 9(2): E138-E141, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28275498

RESUMEN

Pulmonary cryptococcosis is an opportunity infection commonly occurred in the immunocompromised patients. However pulmonary cryptococcosis in the immunocompetent was reported up to 35% and these cases tend to show confined and localized radiologic findings than in immunocompromised patients. To our knowledge, extensive air-space consolidations have not frequently occurred in the immunocompetent patient. Therefore, in this case, we report a rare case of a 73-year-old woman who was diagnosed with pulmonary cryptococcosis, manifesting as diffuse air-space consolidations even though normal immune status. Thus, the possibility of pulmonary cryptococcosis should be considered when a patient with a normal immune status presents without respiratory symptoms are accompanied by consolidation on imaging.

17.
Korean J Radiol ; 18(2): 402-407, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28246521

RESUMEN

OBJECTIVE: To evaluate possible variability in chest radiologists' interpretations of the Lung Imaging Reporting and Data System (Lung-RADS) on difficult-to-classify scenarios. MATERIALS AND METHODS: Ten scenarios of difficult-to-classify imaginary lung nodules were prepared as an online survey that targeted Korean Society of Thoracic Radiology members. In each question, a description was provided of the size, consistency, and interval change (new or growing) of a lung nodule observed using annual repeat computed tomography, and the respondent was instructed to choose one answer from five choices: category 2, 3, 4A, or 4B, or "un-categorizable." Consensus answers were established by members of the Korean Imaging Study Group for Lung Cancer. RESULTS: Of the 420 answers from 42 respondents (excluding multiple submissions), 310 (73.8%) agreed with the consensus answers; eleven (26.2%) respondents agreed with the consensus answers to six or fewer questions. Assigning the imaginary nodules to categories higher than the consensus answer was more frequent (16.0%) than assigning them to lower categories (5.5%), and the agreement rate was below 50% for two scenarios. CONCLUSION: When given difficult-to-classify scenarios, chest radiologists showed large variability in their interpretations of the Lung-RADS categories, with high frequencies of disagreement in some specific scenarios.


Asunto(s)
Neoplasias Pulmonares/diagnóstico , Radiólogos/psicología , Tomografía Computarizada por Rayos X , Humanos , Internet , Pulmón/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Persona de Mediana Edad , Variaciones Dependientes del Observador , Sociedades Médicas , Encuestas y Cuestionarios
18.
Ann Thorac Surg ; 103(3): e267-e270, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28219566

RESUMEN

Immunoglobulin G4 (IgG4)-related sclerosing disease is a recently proposed systemic fibroinflammatory disease entity, with periaortitis as a representative manifestation in the cardiovascular system. We present a case of IgG4-related periaortitis involving the aortic arch and proximal great vessels, mimicking an anterior mediastinal tumor on computed tomography. In patients with a soft tissue mass along the aortic wall, IgG4-related periaortitis should be included as a differential diagnosis and timely serologic investigation should be performed to prevent unnecessary surgery, because the disease shows a remarkable response to corticosteroids.


Asunto(s)
Aorta Torácica/patología , Aortitis/patología , Inmunoglobulina G/sangre , Neoplasias del Mediastino/patología , Aorta Torácica/diagnóstico por imagen , Aortitis/diagnóstico por imagen , Humanos , Masculino , Neoplasias del Mediastino/diagnóstico por imagen , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
19.
PLoS One ; 12(10): e0185774, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28968457

RESUMEN

BACKGROUND/PURPOSE: Although the incidence of Mycobacterium avium complex (MAC) lung disease is increasing, the long-term natural course of the nodular bronchiectatic form of MAC lung disease is not well described. The objective of our study is to evaluate long-term radiologic changes in untreated MAC lung disease by analyzing serial chest computed tomography (CT) scan findings. METHODS: Of 104 patients with MAC lung disease, we selected 40 untreated nodular bronchiectatic MAC patients who underwent serial chest CTs without treatment for at least four years (mean = 6.23 years). Majority of patients have minimal symptoms. Two chest radiologists retrospectively reviewed initial and final chest CT scans. Each chest CT scan was scored for presence and extent of bronchiectasis, cellular bronchiolitis, consolidation, cavity, and nodule (maximum score: 30). RESULTS: Of 40 patients, 39 (97.5%) experienced a significant increase in overall CT score (overall difference = 4.89, p<0.001). On repeated measure analysis of variance analysis, cavity yielded the largest increase compared with cellular bronchiolitis (p = 0.013), nodule (p<0.001), and consolidation (p = 0.004). However, there was no significant difference in mean score change between cavity and bronchiectasis (p = 0.073). In analysis between radiologic parameters and the absolute number of involved segments, bronchiectasis showed most significant change compared with nodule (p<0.001) and consolidation (p<0.001). CONCLUSIONS: Most untreated nodular bronchiectatic MAC lung disease cases showed radiologic deterioration over long-term observation periods when we compared serial chest CT scans. Careful monitoring of MAC lung disease with serial chest CT scan can be beneficial in these untreated patients.


Asunto(s)
Bronquiectasia/patología , Enfermedades Pulmonares/patología , Infección por Mycobacterium avium-intracellulare/patología , Anciano , Bronquiectasia/diagnóstico por imagen , Femenino , Humanos , Enfermedades Pulmonares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Infección por Mycobacterium avium-intracellulare/diagnóstico por imagen , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
20.
PLoS One ; 12(2): e0172568, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28235068

RESUMEN

OBJECTIVES: Despite a sharp increase in e-cigarette use, there is debate about whether e-cigarettes are a viable alternative for harm reduction, and the forms that regulation should take. Healthcare providers can be effective in offering guidance to patients and their families and shaping regulatory policy. We described lung cancer specialists' attitudes toward e-cigarettes and its regulation. METHODS: We undertook a nationwide survey of pulmonologists, thoracic surgeons, medical and radiological oncologists who are members of Korean Association for Lung Cancer. Survey items included beliefs and attitudes toward e-cigarettes, attitudes toward e-cigarette regulation and preparedness on discussing e-cigarettes with their patients. RESULTS: Most respondents believed that e-cigarettes are not safer than conventional tobacco cigarettes (75.7%) or smokeless tobacco (83.2%), and feared that discussing e-cigarettes with the patients would encourage use (65.4%). They did not consider it a smoking cessation treatment (78.3%), and thus would not recommend it to smokers who do not want to quit (82.2%) or who failed to quit with conventional smoking cessation treatment (74.1%). Most respondents supported all examples of e-cigarette regulations, including the safety and quality check (97.8%), warning label (97.8%), advertisement ban (95.1%), restriction of flavoring (78.4%), minimum purchasing age (99.5%), and restriction of indoor use (94.6%). Most learned about e-cigarettes from media and advertisements, or conversation with patients rather than through professional scientific resources, and reported discomfort when discussing e-cigarette with patients. CONCLUSION: Lung cancer specialist physicians in Korea doubt the safety of e-cigarette and use of e-cigarette as smoking cessation treatment, and supported strict regulation. However, only 20% reported that they obtained information on e-cigarettes from the scientific literature and many lacked adequate knowledge based on scientific evidence, suggesting the need for better preparedness. Nevertheless, the views of professionals revealed from our study could help to develop clinical guidelines and regulatory guidance.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina/psicología , Conocimientos, Actitudes y Práctica en Salud , Personal de Salud/psicología , Neoplasias Pulmonares/prevención & control , Oncólogos/psicología , Neumólogos/psicología , Adulto , Sistemas Electrónicos de Liberación de Nicotina/legislación & jurisprudencia , Sistemas Electrónicos de Liberación de Nicotina/estadística & datos numéricos , Femenino , Reducción del Daño , Humanos , Neoplasias Pulmonares/etiología , Masculino , Persona de Mediana Edad , República de Corea , Fumar/efectos adversos , Fumar/psicología , Cese del Hábito de Fumar/métodos , Encuestas y Cuestionarios , Productos de Tabaco/efectos adversos , Tabaquismo/complicaciones , Tabaquismo/psicología , Tabaco sin Humo/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA