Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Assoc Med Microbiol Infect Dis Can ; 8(4): 283-298, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38250616

RESUMEN

Background: In British Columbia (BC), self-collected saline gargle (SG) is the only alternative to health care provider (HCP)-collected nasopharyngeal (NP) swabs to detect SARS-CoV-2 in an outpatient setting by polymerase chain reaction (PCR). However, some individuals cannot perform a SG. Our study aimed to assess combined throat-bilateral nares (TN) swabbing as a swab-based alternative. Methods: Symptomatic individuals greater than 12 years of age seeking a COVID-19 PCR test at one of two COVID-19 collection centres in Metro Vancouver were asked to participate in this study. Participants provided a HCP-collected NP sample and a self-collected SG and TN sample for PCR testing, which were either HCP observed or unobserved. Results: Three-hundred and eleven individuals underwent all three collections. Compared against HCP-NP, SG was 99% sensitive and 98% specific (kappa 0.97) and TN was 99% sensitive and 99% specific (kappa 0.98). Using the final clinical test interpretation as the reference standard, NP was 98% sensitive and 100% specific (kappa 0.98), and both SG and TN were 99% sensitive and 100% specific (both kappa 0.99). Mean cycle threshold values for each viral target were higher in SG specimens compared to the other sample types; however, this did not significantly impact the clinical performance, because the positivity rates were similar. The clinical performance of all specimen types was comparable within the first 7 days of symptom onset, regardless of the observation method. SG self-collections were rated the most acceptable, followed by TN. Conclusions: TN provides another less invasive self-collection modality for symptomatic outpatient SARS-CoV-2 PCR testing.


Historique: En Colombie-Britannique (C.-B.), l'autoprélèvement de gargarisme d'eau saline (GS) est la seule alternative aux écouvillons nasopharyngés (NP) prélevés par un professionnel de la santé (PdS) pour déceler le SRAS-CoV-2 par test PCR en milieu ambulatoire. Cependant, certaines personnes ne peuvent pas effectuer de GS. La présente étude visait évaluer l'écouvillonnage de la gorge et des deux narines (GN) pour remplacer le GS. Méthodologie: Les personnes symptomatiques de plus de 12 ans qui demandaient un test PCR de la COVID-19 à l'un des deux centres de dépistage de la COVID-19 du Grand Vancouver ont été invitées à participer à la présente étude. Les participants ont fourni un prélèvement NP recueilli par un PdS ainsi qu'un autoprélèvement de GS et GN en vue d'un test PCR, observés ou non par un PdS. Résultats: Au total, 311 personnes ont participé aux trois prélèvements. Par rapport au prélèvement NP-PdS, le GS avait une sensibilité de 99 % et une spécificité de 98 % (kappa 0,97) et le prélèvement GN, une sensibilité de 99 % et une spécificité de 99 % (kappa 0, 98). À l'aide de l'interprétation définitive du test clinique comme norme de référence, le prélèvement NP avait une sensibilité de 98 % et une spécificité de 100 % (kappa 0,98) et tant le GS que le prélèvement GN avaient une sensibilité de 99 % et une spécificité de 100 % (deux kappa 0,99). Les valeurs seuils du cycle moyen de chaque cible virale étaient plus élevées dans les échantillons de GS quand dans les autres types d'échantillons, mais n'avaient pas d'effet significatif sur le rendement clinique, puisque les taux de positivité étaient semblables. Le rendement clinique de tous les types d'échantillons était comparable dans les sept premiers jours suivant l'apparition de la maladie, quel que soit le mode d'observation. L'autoprélèvement de GS a été classé comme le plus acceptable, suivi du prélèvement GN. Conclusions: Le prélèvement GN est un autre mode d'autoprélèvement moins invasif chez les patients ambulatoires symptomatiques qui effectuent un test PCR du SRAS-CoV-2.

2.
Int J Cancer ; 126(12): 2885-92, 2010 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-19904755

RESUMEN

We investigated whether there was an association between GBV-C viremia and the development of non-Hodgkin lymphoma (NHL) in 553 NHL cases and 438 controls from British Columbia, Canada. Cases were aged 20-79, diagnosed between March 2000 and February 2004, and resident in Greater Vancouver or Victoria. Cases and controls were tested for GBV-C RNA by RT-PCR and positive samples were genotyped. Overall, GBV-C RNA was detected in 4.5% of NHL cases vs. 1.8% of controls [adjusted odds ratio (OR) = 2.72, 95% confidence interval (CI) = 1.22-6.69]. The association between GBV-C RNA detection and NHL remained even after individuals with a history of prior transfusion, injection drug use and hepatitis C virus sero-positivity were excluded. GBV-C viremia showed the strongest association with diffuse large B cell lymphoma (adjusted OR = 5.18, 95% CI = 2.06-13.71). Genotyping was performed on 29/33 GBV-C RNA positive individuals; genotypes 2a (n = 22); 2b (n = 5) and 3 (n = 2) were identified, consistent with the distribution of genotypes found in North America. This is the largest case-control study to date associating GBV-C viremia and NHL risk. As GBV-C is known to be transmitted through blood products this may have important implications for blood safety.


Asunto(s)
Infecciones por Flaviviridae/virología , Virus GB-C/patogenicidad , Hepatitis Viral Humana/virología , Linfoma no Hodgkin/virología , Adulto , Anciano , Estudios de Casos y Controles , Femenino , Infecciones por Flaviviridae/genética , Hepatitis Viral Humana/genética , Humanos , Linfoma no Hodgkin/genética , Masculino , Persona de Mediana Edad , Embarazo , Prevalencia , Pronóstico , ARN Mensajero/genética , ARN Mensajero/metabolismo , ARN Viral/genética , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Factores de Riesgo , Adulto Joven
3.
J Virol Methods ; 244: 17-22, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28219761

RESUMEN

Hepatitis C virus (HCV) infection affects millions of people and leads to liver fibrosis, cirrhosis, and hepatocellular carcinoma. Treatment regimen selection requires HCV genotype (Gt) and Gt 1 subtype determination. Use of a laboratory developed, reverse transcription (RT)-PCR assay was explored as a low-cost, high-throughput screening approach for the major HCV genotypes and subtypes in North America. A commercial line probe assay (LiPA) was used for comparison. Sequencing and/or an alternative PCR assay were used for discordant analyses. Testing of 155 clinical samples revealed that a paired, duplex real-time RT-PCR assay that targets Gts 1a and 3a in one reaction and Gts 1b and 2 in another had 95% overall sensitivity and individual Gt sensitivity and specificity of 98-100% and 85-98%, respectively. The RT-PCR assay detected mixed HCV Gts in clinical and spiked samples and no false-positive reactions occurred with rare Gts 3b, 4, 5, or 6. Implementation of the RT-PCR assay, with some reflex LiPA testing, would cost only a small portion of the cost of using LiPA alone, and can also save 1.5h of hands-on time. The use of a laboratory developed RT-PCR assay for HCV genotyping has the potential to reduce cost and labour burdens in high-volume testing settings.


Asunto(s)
Genotipo , Técnicas de Genotipaje/métodos , Hepacivirus/clasificación , Hepacivirus/genética , Hepatitis C/virología , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Hepacivirus/aislamiento & purificación , Humanos , América del Norte , Sensibilidad y Especificidad
4.
Vaccine ; 32(5): 624-30, 2014 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-24055350

RESUMEN

We assessed HPV 16 and 18 antibody responses of female subjects enrolled in a 2- vs. 3-dose quadrivalent HPV (Q-HPV) vaccine trial (ClinicalTrials.gov NCT00501137) using the Merck competitive Luminex (cLIA) and total IgG Luminex (TIgG) immunoassays, and a pseudovirus neutralizing antibody (PsV NAb) assay. Subjects were enrolled in one of three groups: (1) 9-13yr, 2 doses of Q-HPV at 0, 6 months (n=259); (2) 9-13yr, 3 doses at 0, 2, 6 months (n=260); and (3) 16-26yr, 3 doses at 0, 2, 6 months (n=305). Sera were collected from all subjects at baseline, months 7 and 24, and from half the subjects at months 18 and 36. High correlation was observed between all three assays. At month 36, HPV 16 antibodies remained detectable in all subjects by all assays, whereas 86.4%, 99.6% and 100% of subjects respectively were HPV 18 cLIA, TIgG and PsV NAb (partial neutralization endpoint) seropositive. The proportion seropositive for HPV 18 by cLIA at 36 months was not significantly different for 2-dose girls vs. 3-dose adults (85.9% vs. 79.4%; p=0.51), whereas the proportion for 3-dose girls was significantly higher than for 3-dose adults (95.3% vs. 79.4%; p<0.01). The HPV 18 seropositive proportions by the TIgG and PsV NAb (partial neutralization endpoint) assays were the same for all subjects. High baseline HPV 16 and HPV 18 seropositivity was observed for the TIgG assay and it is unclear if all the detected TIgG antibodies are type-specific and/or neutralizing. For the PsV NAb assay, 90% and partial neutralization geometric mean titres were consistently 2-8-fold higher than for 100% neutralization, which enabled detection of HPV 18 NAb in subjects who lost detectable cLIA antibodies over time. We conclude that the PsV NAb assay is more sensitive than the cLIA, and likely more specific than the TIgG assay.


Asunto(s)
Anticuerpos Antivirales/sangre , Inmunoensayo/métodos , Vacunas contra Papillomavirus/administración & dosificación , Adolescente , Adulto , Anticuerpos Neutralizantes/sangre , Niño , Femenino , Papillomavirus Humano 16 , Papillomavirus Humano 18 , Humanos , Esquemas de Inmunización , Pruebas de Neutralización , Infecciones por Papillomavirus/inmunología , Infecciones por Papillomavirus/prevención & control , Sensibilidad y Especificidad , Adulto Joven
5.
Clin Vaccine Immunol ; 18(3): 418-23, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21248158

RESUMEN

Human papillomavirus 16 (HPV 16) and HPV 18 antibody responses in a 2- versus 3-dose HPV vaccine (Gardasil) trial were measured by a pseudovirus neutralizing antibody (PsV NAb) assay and by the Merck competitive Luminex immunoassay (cLIA). Eight hundred twenty-four female subjects assigned to three dosing regimens (group 1, 9 to 13 years old; 2 doses, months 0 and 6 [n = 259]; group 2, 9 to 13 years old; 3 doses, months 0, 2, and 6 [n = 260]; group 3, 16 to 26 years old; 3 doses, months 0, 2, and 6 [n = 305]) had postvaccine responses assessed 1 month after the last dose. Of 791 subjects with baseline and 7-month sera, 15 (1.9%) and 9 (1.1%) were baseline seropositive for HPV 16 and HPV 18, respectively. All baseline-seronegative vaccinees seroconverted to both HPV 16 and HPV 18. Mean anti-HPV 16 levels were similar for groups 1 and 2 (for PsV NAb, P = 0.675; for cLIA, P = 0.874), and levels for both groups 1 and 2 were approximately 2-fold higher than that for group 3 (for PsV NAb and cLIA, P < 0.001). Mean anti-HPV 18 levels were approximately 1.4-fold lower in group 1 than in group 2 (for PsV, NAb P = 0.013; for cLIA, P = 0.001), and levels for both groups 1 and 2 were approximately 2.0- to 2.5-fold higher than that for group 3 (for PsV NAb and cLIA, P < 0.001). Pearson correlation coefficients for the assays were 0.672 for HPV 16 and 0.905 for HPV 18. Most of the discordant results were observed at lower cLIA signals. These results suggest that the PsV NAb assay could be a suitable alternative to cLIA for the measurement of postvaccine antibody responses.


Asunto(s)
Anticuerpos Neutralizantes/sangre , Anticuerpos Antivirales/sangre , Técnicas de Laboratorio Clínico/métodos , Papillomavirus Humano 16/inmunología , Papillomavirus Humano 18/inmunología , Vacunas contra Papillomavirus/inmunología , Adolescente , Adulto , Niño , Ensayo de Inmunoadsorción Enzimática/métodos , Femenino , Vacuna Tetravalente Recombinante contra el Virus del Papiloma Humano Tipos 6, 11 , 16, 18 , Humanos , Inmunoensayo/métodos , Adulto Joven
7.
Emerg Infect Dis ; 10(12): 2192-5, 2004 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-15663859

RESUMEN

Genome sequences of chicken (low pathogenic avian influenza [LPAI] and highly pathogenic avian influenza [HPAI]) and human isolates from a 2004 outbreak of H7N3 avian influenza in Canada showed a novel insertion in the HA0 cleavage site of the human and HPAI isolate. This insertion likely occurred by recombination between the hemagglutination and matrix genes in the LPAI virus.


Asunto(s)
Brotes de Enfermedades/veterinaria , Virus de la Influenza A/genética , Gripe Aviar/epidemiología , Secuencia de Aminoácidos , Animales , Colombia Británica/epidemiología , Pollos , Humanos , Virus de la Influenza A/patogenicidad , Gripe Aviar/virología , Modelos Moleculares , Datos de Secuencia Molecular , Mutagénesis Insercional , Conformación Proteica , Alineación de Secuencia , Proteínas Virales/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA