Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 148(1): 35-46, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37199171

RESUMEN

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Femenino , Persona de Mediana Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda , Resultado del Tratamiento , Aleteo Atrial/etiología , Sistema de Registros , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
2.
Artículo en Inglés | MEDLINE | ID: mdl-38750671

RESUMEN

BACKGROUND: Management of atrial fibrillation (AF) in very severe obese patients is challenging. Cryoballoon ablation (CBA) represents an effective rhythm control strategy. However, data in this patient group were limited. METHODS: Highly symptomatic AF patients with body mass index (BMI) ≥ 40 kg/m2 who had failed antiarrhythmic drug therapy and electrocardioversion and failure to achieve targeted body-weight-reduction underwent CBA. RESULTS: Data of 72 very severe obese AF patients (Group A) and 129 AF patients with normal BMI (Group B, BMI < 25 kg/m2) were consecutively collected. Group A had significantly younger age (60.6 ± 10.4 vs. 69.2 ± 11.2 years), higher BMI (44.3 ± 4.3 vs. 22.5 ± 1.6 kg/m2). Procedural pulmonary vein isolation (PVI) was successful in all patients (2 touch-up ablation in Group A). Compared to Group B, Group A had similar procedural (61.3 ± 22.6 vs. 57.5 ± 19 min), similar fluoroscopy time (10.1 ± 5.5 vs. 9.2 ± 4.8 min) but significantly higher radiation dose (2852 ± 2095 vs. 884 ± 732 µGym2). We observed similar rates of real-time-isolation (78.6% vs. 78.5%), single-shot-isolation (86.5% vs. 88.8%), but significantly longer time-to-sustained-isolation (53.5 ± 33 vs. 43.2 ± 25 s). There was significantly higher rate of puncture-site-complication (6.9% vs. 1.6%) in Group A. One-year clinical success in paroxysmal AF was (Group A: 69.4% vs. Group B: 80.2%; p < .001), in persistent AF was (Group A: 58.1% vs. Group B: 62.8%; p = .889). In Re-Do procedures Group A had a numerically lower PVI durability (75.0% vs. 83.6%, p = .089). CONCLUSION: For very severe obese AF patients, CBA appears feasible, leads to relatively good clinical outcome.

3.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38781099

RESUMEN

AIMS: Cardioneuroablation (CNA) is a catheter-based intervention for recurrent vasovagal syncope (VVS) that consists in the modulation of the parasympathetic cardiac autonomic nervous system. This survey aims to provide a comprehensive overview of current CNA utilization in Europe. METHODS AND RESULTS: A total of 202 participants from 40 different countries replied to the survey. Half of the respondents have performed a CNA during the last 12 months, reflecting that it is considered a treatment option of a subset of patients. Seventy-one per cent of respondents adopt an approach targeting ganglionated plexuses (GPs) systematically in both the right atrium (RA) and left atrium (LA). The second most common strategy (16%) involves LA GP ablation only after no response following RA ablation. The procedural endpoint is frequently an increase in heart rate. Ganglionated plexus localization predominantly relies on an anatomical approach (90%) and electrogram analysis (59%). Less utilized methods include pre-procedural imaging (20%), high-frequency stimulation (17%), and spectral analysis (10%). Post-CNA, anticoagulation or antiplatelet therapy is prescribed, with only 11% of the respondents discharging patients without such medication. Cardioneuroablation is perceived as effective (80% of respondents) and safe (71% estimated <1% rate of procedure-related complications). Half view CNA emerging as a first-line therapy in the near future. CONCLUSION: This survey offers a snapshot of the current implementation of CNA in Europe. The results show high expectations for the future of CNA, but important heterogeneity exists regarding indications, procedural workflow, and endpoints of CNA. Ongoing efforts are essential to standardize procedural protocols and peri-procedural patient management.


Asunto(s)
Ablación por Catéter , Síncope Vasovagal , Humanos , Síncope Vasovagal/fisiopatología , Síncope Vasovagal/cirugía , Síncope Vasovagal/diagnóstico , Europa (Continente) , Ablación por Catéter/métodos , Flujo de Trabajo , Frecuencia Cardíaca , Resultado del Tratamiento , Encuestas de Atención de la Salud , Pautas de la Práctica en Medicina/tendencias , Técnicas Electrofisiológicas Cardíacas , Encuestas y Cuestionarios , Ganglios Autónomos/cirugía , Ganglios Autónomos/fisiopatología , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Recurrencia
4.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38666444

RESUMEN

Stereotactic arrhythmia radioablation (STAR) is a treatment option for recurrent ventricular tachycardia/fibrillation (VT/VF) in patients with structural heart disease (SHD). The current and future role of STAR as viewed by cardiologists is unknown. The study aimed to assess the current role, barriers to application, and expected future role of STAR. An online survey consisting of 20 questions on baseline demographics, awareness/access, current use, and the future role of STAR was conducted. A total of 129 international participants completed the survey [mean age 43 ± 11 years, 25 (16.4%) female]. Ninety-one (59.9%) participants were electrophysiologists. Nine participants (7%) were unaware of STAR as a therapeutic option. Sixty-four (49.6%) had access to STAR, while 62 (48.1%) had treated/referred a patient for treatment. Common primary indications for STAR were recurrent VT/VF in SHD (45%), recurrent VT/VF without SHD (7.8%), or premature ventricular contraction (3.9%). Reported main advantages of STAR were efficacy in the treatment of arrhythmias not amenable to conventional treatment (49%) and non-invasive treatment approach with overall low expected acute and short-term procedural risk (23%). Most respondents have foreseen a future clinical role of STAR in the treatment of VT/VF with or without underlying SHD (72% and 75%, respectively), although only a minority expected a first-line indication for it (7% and 5%, respectively). Stereotactic arrhythmia radioablation as a novel treatment option of recurrent VT appears to gain acceptance within the cardiology community. Further trials are critical to further define efficacy, patient populations, as well as the appropriate clinical use for the treatment of VT.


Asunto(s)
Radiocirugia , Taquicardia Ventricular , Fibrilación Ventricular , Humanos , Femenino , Masculino , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/fisiopatología , Adulto , Persona de Mediana Edad , Fibrilación Ventricular/cirugía , Fibrilación Ventricular/fisiopatología , Radiocirugia/tendencias , Encuestas de Atención de la Salud , Técnicas Electrofisiológicas Cardíacas , Recurrencia , Resultado del Tratamiento , Pautas de la Práctica en Medicina/tendencias , Pautas de la Práctica en Medicina/estadística & datos numéricos , Cardiólogos/tendencias , Electrofisiología Cardíaca/tendencias
5.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38363995

RESUMEN

Ventricular tachycardia (VT), and its occurrence, is still one of the main reasons for sudden cardiac death and, therefore, for increased mortality and morbidity foremost in patients with structural heart [Kahle A-K, Jungen C, Alken F-A, Scherschel K, Willems S, Pürerfellner H et al. Management of ventricular tachycardia in patients with ischaemic cardiomyopathy: contemporary armamentarium. Europace 2022;24:538-51]. Catheter ablation has become a safe and effective treatment option in patients with recurrent VT [Cronin EM, Bogun FM, Maury P, Peichl P, Chen M, Namboodiri N et al. 2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias. Heart Rhythm 2020;17:e2-154]. Previous and current guidelines provide guidance on indication for VT ablation and risk assessment and evaluation of underlying disease. However, no uniform recommendation is provided regarding procedural strategies, timing of ablation, and centre setting. Therefore, these specifics seem to differ largely, and recent data are sparse. This physician-based European Heart Rhythm Association survey aims to deliver insights on not only infrastructural settings but also procedural specifics, applied technologies, ablation strategies, and procedural endpoints. Therefore, these findings might deliver a real-world scenario of VT management and potentially are of guidance for other centres.


Asunto(s)
Ablación por Catéter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Flujo de Trabajo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Arritmias Cardíacas/cirugía , Resultado del Tratamiento , Ablación por Catéter/métodos
6.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38227804

RESUMEN

AIMS: Although guidelines for the management of atrial fibrillation (AF) are regularly published, many controversial issues remain, limiting their implementation. We aim to describe current clinical practice among European Heart Rhythm Association (EHRA) community according to last guidelines. METHODS AND RESULTS: A 30 multiple-choice questionnaire covering the most controversial topics related to AF management was distributed through the EHRA Research Network, National Societies, and social media between January and February 2023. One hundred and eighty-one physicians responded the survey, 61% from university hospitals. Atrial fibrillation screening in high-risk patients is regularly performed by 57%. Only 42% has access to at least one programme aiming at diagnosing/managing comorbidities and lifestyle modifications, with marked heterogeneity between countries. Direct oral anticoagulants are the preferred antithrombotic (97%). Rhythm control is the preferred strategy in most AF phenotypes: symptomatic vs. asymptomatic paroxysmal AF (97% vs. 77%), low vs. high risk for recurrence persistent AF (90% vs. 72%), and permanent AF (20%). I-C drugs and amiodarone are preferred while dronedarone and sotalol barely used. Ablation is the first-line therapy for symptomatic paroxysmal AF (69%) and persistent AF with markers of atrial disease (57%) and is performed independently of symptoms by 15%. In persistent AF, 68% performs only pulmonary vein isolation and 32% also additional lesions. CONCLUSION: There is marked heterogeneity in AF management and limited accordance to last guidelines in the EHRA community. Most of the discrepancies are related to the main controversial issues, such as those related to AF screening, management of comorbidities, pharmacological treatment, and ablation strategy.


Asunto(s)
Fibrilación Atrial , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Comorbilidad , Encuestas y Cuestionarios , Sotalol , Anticoagulantes/uso terapéutico , Resultado del Tratamiento
7.
Europace ; 25(2): 676-681, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36372986

RESUMEN

Atrial fibrillation (AF) is a major challenge for the healthcare field. Pulmonary vein isolation is the most effective treatment for the maintenance of sinus rhythm. However, clinical endpoints for the procedure vary significantly among studies. There is no consensus on the definition of recurrence and no clear roadmap on how to deal with recurrences after a failed ablation. The purpose of this study was to perform a survey in order to show how clinicians currently approach this knowledge gap. An online survey, supported by the European Heart Rhythm Association (EHRA) Scientific Initiatives Committee, was conducted between 1 April 2022 and 8 May 2022. An anonymous questionnaire was disseminated via social media and EHRA newsletters, for clinicians to complete. This consisted of 18 multiple-choice questions regarding rhythm monitoring, definitions of a successful ablation, clinical practices after a failed AF ablation, and the continuance of anticoagulation. A total of 107 replies were collected across Europe. Most respondents (82%) perform routine monitoring for AF recurrences after ablation, with 51% of them preferring a long-term monitoring strategy. Cost was reported to have an impact on the choice of monitoring strategy. Self-screening was recommended by most (71%) of the respondents. The combination of absence of symptoms and recorded AF was the definition of success for most (83%) of the respondents. Cessation of anticoagulation after ablation was an option mostly for patients with paroxysmal AF and a low CHA2DS2-VASc score. The majority of physicians perform routine monitoring after AF ablation. For most physicians, the combination of the absence of symptoms and electrocardiographic endpoints defines a successful result after AF ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Resultado del Tratamiento , Europa (Continente)/epidemiología , Anticoagulantes/efectos adversos , Encuestas y Cuestionarios , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
8.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37682245

RESUMEN

AIMS: This study aims to survey current educational experience and the individual requirements for electrophysiologists in training. METHODS AND RESULTS: The European Heart Rhythm Association (EHRA) e-Communication Committee and the Scientific Initiatives Committee prepared a questionnaire and distributed it via newsletters, Twitter, LinkedIn, and Facebook. The survey consisted of 22 questions collected on an individual basis anonymously. Two hundred and forty-three responders from 35 countries (32% female, age 38 ± 6 years old) completed the survey. This EHRA electrophysiology (EP) fellowship survey showed that (i) hands-on participation and observation of EP procedures are very important; (ii) the main motivations to choose the EP fellowship institution are centre reputation and volume as well as the availability of a structured EP fellowship programme; (iii) 59% passed the EHRA exam and 46% took a national certification exam; (iv) respondents are overall satisfied with their own fellowships, but there are areas of less confidence such as conduction system pacing implantation and cardiac resynchronization therapy implantation; (v) 78% of respondents performed research during their fellowship, (vi) the optimal duration of an EP fellowship should be at least 2 years; and (viii) doing fellowships abroad is beneficial, but significant obstacles exist. CONCLUSION: The results of this EHRA survey may help to refine current EP fellowship programmes to improve the quality of EP training and early career building of young electrophysiologists.


Asunto(s)
Terapia de Resincronización Cardíaca , Becas , Humanos , Femenino , Adulto , Masculino , Trastorno del Sistema de Conducción Cardíaco , Electrofisiología Cardíaca , Certificación
9.
Europace ; 25(3): 1144-1151, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36691111

RESUMEN

AIMS: Information provided to patients prior to implantable cardioverter-defibrillator (ICD) insertion and their participation in the decision-making process are crucial for understanding ICD function and accepting this lifelong therapy. The aim of this study is to evaluate the extent to which different aspects related to ICD and quality of life were transmitted to patients prior to ICD implantation. METHODS AND RESULTS: Prospective, multicenter European study with an online questionnaire initiated by the European Heart Rhythm Association. The questionnaire was filled-in directly and personally by the ICD patients who were invited to participate. A total of 1809 patients (majority in their 40s-70s, with 624 women, 34.5%) from 10 European countries participated in the study. The median time from first ICD implantation was 5 years (interquartile range 2-10). Overall, 1155 patients (71.5%) felt optimally informed at the time of device implantation, however many respondents received no information about ICD-related complications (n = 801, 49.6%), driving restrictions (n = 718, 44.5%), and possibility of end-of-life ICD deactivation (n = 408, 25.4%). Of note, women were less frequently involved in the decision-making process than men (47.3% vs. 55.9%, P = 0.003) and reported to be less often optimally informed before ICD implantation than men (61.2% vs. 76.8%, P < 0.001). More women mentioned the desire to have learned more about ICD therapy and the benefit/risk balance (45.4% vs. 33.7% of men; P < 0.001). CONCLUSIONS: This patient-based evaluation provides alarming findings on the lack of information provided to patients prior ICD implantation, particularly for women.


Asunto(s)
Desfibriladores Implantables , Calidad de Vida , Masculino , Humanos , Femenino , Estudios Prospectivos , Cardioversión Eléctrica/efectos adversos , Desfibriladores Implantables/efectos adversos , Europa (Continente) , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control
10.
Europace ; 26(1)2023 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-38091971

RESUMEN

Limited data are available regarding venous thromboembolism (VTE), specifically deep vein thrombosis (DVT) and pulmonary embolism (PE), following right-sided ablations and electrophysiological (EP) studies. Compared to left-sided procedures, no guidelines on antithrombotic management strategies for the prevention of DVT and PE are available. The main purpose of the present European Heart Rhythm Association (EHRA) survey is to report the current management of right-sided EP procedures, focusing on anticoagulation and prevention of VTE. An online survey was conducted using the EHRA infrastructure. A total of 244 participants answered a 19-items questionnaire on the periprocedural management of EP studies and right-sided catheter ablations. The right femoral vein is the most common access for EP studies and right-sided procedures. An ultrasound-guided approach is employed by more than 2/3 of respondents. Intravenous heparin is not commonly given by the majority of participants. About 1/3 of participants (34%) routinely prescribe VTE prophylaxis during (mostly aspirin and low molecular weight heparin) and 1/4 of respondents (25%) commonly prescribe VTE prophylaxis after discharge (mostly aspirin). Of note, respectively 13% and 9% of participants observed at least one DVT and one PE related to right-sided ablation or EP study within the last year in their center. The present survey shows that only a minority of operators routinely gives intraprocedural intravenous heparin and prescribes VTE prophylaxis after right-sided EP procedures. Compared to left-sided procedures like atrial fibrillation (AF) ablation, there are no consistent systematic antithrombotic management strategies.


Asunto(s)
Embolia Pulmonar , Tromboembolia Venosa , Humanos , Tromboembolia Venosa/epidemiología , Tromboembolia Venosa/prevención & control , Anticoagulantes/uso terapéutico , Fibrinolíticos/uso terapéutico , Heparina , Embolia Pulmonar/prevención & control , Embolia Pulmonar/tratamiento farmacológico , Aspirina , Encuestas y Cuestionarios
11.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37498147

RESUMEN

AIMS: Electrophysiology (EP) is a growing field in cardiology, with an increasing involvement of young people. Nevertheless, concerns about radiation exposure and its impact on reproduction and pregnancy may discourage the choice of an EP career. The study is aimed at investigating the level of awareness and main sources of concern about the effects of radiation on reproductive potential and pregnancy, exploring the safety measures adopted in different EP labs, and verifying the adherence to the current guidelines. METHODS AND RESULTS: An online survey was conducted using the European Heart Rhythm Association (EHRA) infrastructure from April to June 2022. A total of 252 EP personnel (42% women) participated, from 50 countries and different professional roles. Most participants expressed concerns regarding the effects of radiation on reproductive capacity (67.1%) and offspring diseases (68.2%). Only 37.9% of participants were aware of the EHRA 2017 consensus document about occupational radiation exposure. Most participants (80.9%) considered that occupational radiation during pregnancy is not safe. EP female staff were not allowed to work in the EP lab during pregnancy in 48.1% of cases. Zero-fluoroscopy was the preferred choice to continue working in the EP lab during pregnancy. CONCLUSION: EP staff, including both men and women, have concerns about the effects of radiation on reproductive capacity. Despite the recommendations issued by international bodies, implementation of the policies regarding pregnancy and occupational radiation exposure is heterogeneous. Zero-fluoroscopy is the preferred approach to ensure safety during pregnancy in the EP lab.


Asunto(s)
Exposición Profesional , Exposición a la Radiación , Traumatismos por Radiación , Masculino , Embarazo , Femenino , Humanos , Adolescente , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Encuestas y Cuestionarios , Reproducción , Electrofisiología Cardíaca , Exposición Profesional/efectos adversos , Exposición Profesional/prevención & control , Dosis de Radiación
12.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37116126

RESUMEN

AIMS: A novel irrigated radiofrequency (RF) balloon (RFB) for pulmonary vein (PV) isolation (PVI) was released in selected centres. We pooled the procedural data on efficacy and safety of RFB-PVI from two high volume German centres. METHODS AND RESULTS: Consecutive patients with RFB procedures were enrolled. A 3D electroanatomical left atrial map guided the RFB navigation. Every RF delivery lasted 60 s, and duration was automatically reduced to 20 s for electrodes facing the posterior wall. Procedural data and post-procedural endoscopy data (<48 h) were analysed. Data from 140 patients were collected (57% male, 67 ± 11 years, 57% paroxysmal atrial fibrillation). There were 547 PVs identified, and 99.1% could be isolated using solely the RFB. Single-shot PVI was recorded in 330/547 (60%) PVs. Median time to isolation during the first application was 10 s (IQR 8-13). A total of 2.1 ± 1.8 applications per PV were delivered, with the left superior PV requiring more application compared to other PVs. Median procedure and fluoroscopy time were 77 min (61-99) and 13 min (10-17), respectively. Major safety events were recorded only in the first 25 cases at each centre and included 1/140(0.7%) cardiac tamponade, 1/140(0.7%) phrenic nerve palsy, and 2/140 strokes (1.4%). An oesophageal temperature rise was recorded in 81/547 (15%) PVs, and endoscopy detected oesophageal lesions in 7/85 (8%) patients undergoing endoscopy. CONCLUSION: The RFB showed a high efficacy allowing for fast PVI procedures, and 60% of PVs could be isolated at the first application. Most safety events were recorded during the learning phase. An oesophageal temperature monitoring is suggested: oesophageal lesions were detected in 8% of patients.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Femenino , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Atrios Cardíacos , Venas Pulmonares/cirugía
13.
Europace ; 25(7)2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37440757

RESUMEN

AIMS: Patients with atrial fibrillation who despite taking oral anti-coagulant therapy (OAT) suffer a stroke or systemic embolism (SSE) without vascular cause or who develop left atrial appendage (LAA) thrombus (LAAT) should be considered as having malignant LAA. The optimal treatment strategy to reduce SSE risk in such patients is unknown. The aim of the study is to investigate the diagnostic and therapeutic pathways for malignant LAA practiced in European cardiac centres. METHODS AND RESULTS: An 18-item online questionnaire on malignant LAA was disseminated by the European Heart Rhythm Association (EHRA) Scientific Initiatives Committee. A total of 196 physicians participated in the survey. There seems to be high confidence in transoesophageal echocardiography (TEE) imaging, considering LAAT diagnosis. Switching to another direct oral anti-coagulant (DOAC) is the preferred initial step for the treatment of malignant LAA followed by a switch to vitamin K antagonist (VKA), low-molecular-weight heparin, or continued/optimized DOAC dosage, whereas LAA closure is the last option. Left atrial appendage closure is a viable option in patients with embolic stroke despite OAT and no evidence of thrombus at TEE (empty LAA) after comprehensive diagnostic measures to exclude other sources of embolism. CONCLUSION: This EHRA survey provides a snapshot of the contemporary management of patients diagnosed with malignant LAA. Currently, the majority of patients are treated on an outpatient basis with either shifting from VKA to DOAC or from one DOAC to another. Left atrial appendage closure in this population seems to be reserved for patients with higher bleeding risk or complications of malignant LAA, such as stroke.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Embolia , Cardiopatías , Accidente Cerebrovascular , Trombosis , Humanos , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/complicaciones , Anticoagulantes/uso terapéutico , Ecocardiografía Transesofágica , Trombosis/epidemiología , Fibrinolíticos/uso terapéutico , Encuestas y Cuestionarios , Resultado del Tratamiento
14.
Europace ; 25(10)2023 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-37789664

RESUMEN

AIMS: Electrophysiological (EP) operations that have traditionally involved long hospital lengths of stay (LOS) are now being undertaken as day case procedures. The coronavirus disease-19 pandemic served as an impetus for many centres to shorten LOS for EP procedures. This survey explores LOS for elective EP procedures in the modern era. METHODS AND RESULTS: An online survey consisting of 27 multiple-choice questions was completed by 245 respondents from 35 countries. With respect to de novo cardiac implantable electronic device (CIED) implantations, day case procedures were reported for 79.5% of implantable loop recorders, 13.3% of pacemakers (PMs), 10.4% of implantable cardioverter defibrillators (ICDs), and 10.2% of cardiac resynchronization therapy (CRT) devices. With respect to CIED generator replacements, day case procedures were reported for 61.7% of PMs, 49.2% of ICDs, and 48.2% of CRT devices. With regard to ablations, day case procedures were reported for 5.7% of atrial fibrillation (AF) ablations, 10.7% of left-sided ablations, and 17.5% of right-sided ablations. A LOS ≥ 2 days for CIED implantation was reported for 47.7% of PM, 54.5% of ICDs, and 56.9% of CRT devices and for 54.5% of AF ablations, 42.2% of right-sided ablations, and 46.1% of left-sided ablations. Reimbursement (43-56%) and bed availability (20-47%) were reported to have no consistent impact on the organization of elective procedures. CONCLUSION: There is a wide variation in the LOS for elective EP procedures. The LOS for some procedures appears disproportionate to their complexity. Neither reimbursement nor bed availability consistently influenced LOS.


Asunto(s)
Fibrilación Atrial , COVID-19 , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Humanos , Terapia de Resincronización Cardíaca/métodos , Tiempo de Internación , COVID-19/epidemiología , Encuestas y Cuestionarios
15.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37140046

RESUMEN

AIMS: The aim of this study was to identify potential regional disparities in characteristics of implantable cardioverter-defibrillator (ICD) recipients, patient perceptions and perspectives after implantation and level of information provided to patients. METHODS AND RESULTS: The prospective, multicentre, and multinational European Heart Rhythm Association patient Survey 'Living with an ICD' included patients already implanted with an ICD (median ICD dwell time - 5 years, interquartile range 2-10). An online questionnaire was filled-in by patients invited from 10 European countries. A total of 1809 patients (the majority in their 40s to 70s, 65.5% men) were enrolled, with 877 (48.5%) from Western Europe (group 1), followed by 563 from Central/Eastern Europe (group 2, 31.1%), and 369 from Southern Europe (group 3, 20.4%). A total of 52.9% of Central/Eastern Europe patients reported increased satisfaction after ICD placement compared with 46.6% from Western and 33.1% from Southern Europe (1 vs. 2 P = 0.047, 1 vs. 3 P < 0.001, 2 vs. 3 P < 0.001). About 79.2% of Central/Eastern and 76.0% of Southern Europe patients felt optimally informed at the time of device implantation compared with just 64.6% from Western Europe (1 vs. 2 P < 0.001, 1 vs. 3 P < 0.001, 2 vs. 3 P = ns). CONCLUSIONS: While physicians in Southern Europe should address the patients' concerns about the impact of the ICD on quality of life, physicians from Western Europe should focus on improving the quality of information provided to their prospective ICD patients. Novel strategies to address regional differences in patients' quality of life and provision of information are warranted.


Asunto(s)
Desfibriladores Implantables , Masculino , Humanos , Femenino , Calidad de Vida , Estudios Prospectivos , Encuestas y Cuestionarios , Europa (Continente)/epidemiología
16.
Europace ; 25(2): 374-381, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36414239

RESUMEN

AIMS: Cryoballoon (CB)-based pulmonary vein isolation (PVI) is an effective treatment for atrial fibrillation (AF). The most frequent complication during CB-based PVI is right-sided phrenic nerve injury (PNI) which is leading to premature abortion of the freeze cycle. Here, we analysed reconnection rates after CB-based PVI and PNI in a large-scale population during repeat procedures. METHODS AND RESULTS: In the YETI registry, a total of 17 356 patients underwent CB-based PVI in 33 centres, and 731 (4.2%) patients experienced PNI. A total of 111/731 (15.2%) patients received a repeat procedure for treatment of recurrent AF. In 94/111 (84.7%) patients data on repeat procedures were available. A total of 89/94 (94.7%) index pulmonary veins (PVs) have been isolated during the initial PVI. During repeat procedures, 22 (24.7%) of initially isolated index PVs showed reconnection. The use of a double stop technique did non influence the PV reconnection rate (P = 0.464). The time to PNI was 140.5 ± 45.1 s in patients with persistent PVI and 133.5 ± 53.8 s in patients with reconnection (P = 0.559). No differences were noted between the two populations in terms of CB temperature at the time of PNI (P = 0.362). The only parameter associated with isolation durability was CB temperature after 30 s of freezing. The PV reconnection did not influence the time to AF recurrence. CONCLUSION: In patients with cryoballon application abortion due to PNI, a high rate of persistent PVI rate was found at repeat procedures. Our data may help to identify the optimal dosing protocol in CB-based PVI procedures. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT03645577?term=YETI&cntry=DE&draw=2&rank=1 ClinicalTrials.gov Identifier: NCT03645577.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Criocirugía/métodos , Nervio Frénico , Venas Pulmonares/cirugía , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
17.
Pacing Clin Electrophysiol ; 46(5): 414-418, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36424836

RESUMEN

Pulsed field ablation (PFA) using high-voltage electrical energy is a novel and powerful ablation modality. However, PFA as a first-line rhythm control in atrial fibrillation (AF) has been rarely described; whether PFA interacts with the pacemaker (PM) has been seldom reported. We reported PFA of AF in a patient with PM who needed effective rhythm control. Pulmonary vein isolation (PVI) was successfully performed without complication, and the procedure was extremely fast (skin-to-skin 25 min.) with short fluoroscopic time (3.9 min). PFA had no influence on the PM function. Six months' follow-up showed good clinical outcome and significantly decreased AF burden.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Resultado del Tratamiento , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Recurrencia
18.
J Cardiovasc Electrophysiol ; 33(7): 1371-1379, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35488736

RESUMEN

BACKGROUND: The iCLAS ultra-low temperature cryoablation (ULTC) system has recently been brought to the market. A combination of a newly exploited cryogen and interchangeable stylet enables flexible and continuous lesion creation in atrial fibrillation (AF) ablation. The use of an esophageal warming balloon is recommended when using the system to reduce the potential for collateral esophageal injury. OBJECTIVE: To describe the initial clinical experience when using ULTC in the AF treatment without general anesthesia (GA). METHODS: Consecutive patients undergoing AF ablation using ULTC under deep sedation without GA were enrolled. We assessed the procedural data focusing on "single-shot isolation" defined as successful pulmonary vein (PV) isolation after the first application. Esophagogastroduodenoscopy was systematically performed the day after ablation. RESULTS: A total of 27 AF patients (67% paroxysmal AF) were analyzed. Onehundred four out of 106 PVs (98.1%) were isolated solely using ULTC. The mean procedure time was 79 ± 30 min. The mean number of applications per PV was 2.6 ± 1.0. Single-shot isolation was achieved in 57 PVs (54%) varying across PVs from left superior to inferior PVs (40%-64%). The single procedure 6-month recurrence-free rate was 84%. No major complication (cerebrovascular event, pericardial effusion/tamponade, esophageal damage on esophagogastroduodenoscopy) occurred. A single transient phrenic nerve palsy occurred during the right superior PV ablation, which had recovered by the 3-month follow-up appointment. CONCLUSIONS: AF ablation using the novel ULTC system seemed feasible without GA and enabled a >50% single-shot isolation rate. The promising safety profile has to be confirmed in large-scale studies.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Catéteres , Criocirugía/efectos adversos , Criocirugía/métodos , Humanos , Venas Pulmonares/cirugía , Temperatura , Resultado del Tratamiento
19.
Europace ; 24(Suppl 2): ii8-ii13, 2022 06 06.
Artículo en Inglés | MEDLINE | ID: mdl-35661870

RESUMEN

Ablation of atrial fibrillation (AF) is an established treatment option for symptomatic patients. The cornerstone of all ablation strategies is electrical isolation of the pulmonary veins (PVs). Ablation strategies going beyond PV isolation (PVI) might be considered in the setting of recurrent AF despite durably isolated PVs. The lack of persistent PVI, however, limits the opportunities to perceive the real impact of this endpoint on AF suppression and to fully understand the benefit of extended ablation strategies going beyond. To overcome this limitation, novel and innovative ablation systems have been developed to facilitate acute PVI and to increase its durability. These systems include balloon-based ablation devices incorporating different energy sources such as cryo energy, laser, or radiofrequency current, but also new energy sources such as pulsed field ablation as a non-thermal energy source. These technologies could advance catheter ablation of AF to an early stage of the disease and to the primary treatment tool. The current manuscript focuses on the past, the present, and the future value of PVI as the cornerstone for interventional treatment of AF and on how to achieve durable PVI during the first procedure and to further improve the clinical success rates of AF ablation. It also analyses extended ablation strategies going beyond PVI and their impact.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
20.
Europace ; 24(4): 691-696, 2022 04 05.
Artículo en Inglés | MEDLINE | ID: mdl-34626177

RESUMEN

Social media (SoMe) represents a medium of communication in everyday life and has gained importance for professional use among clinicians. In the #intEHRAct survey, we aimed to describe the use of SoMe by the healthcare community in a professional setting. The EHRA e-Communication Committee and the Scientific Initiatives Committee prepared a questionnaire and distributed it via newsletters, Twitter, LinkedIn, and Facebook. The survey consisted of 19 questions made on an individual basis and collected anonymously. Two hundred and eighty-five responders from 35 countries (72.3% male, age 49 ± 11 years old) completed the survey. Most respondents (42.7%) declared to use SoMe as passive users while 38.3% and 19.0% declared to share content on a non-daily and daily basis, respectively. The respondents estimated they spent a median of 5 (Q1-Q3: 2-10) h per week on SoMe. The most widely used SoMe was LinkedIn (60.8%), but the use of each platform was heterogeneous between countries. Among the advantages of SoMe, respondents indicated the chance of being updated on recent publications (66.0%), networking (48.5%), and the availability of rare or interesting cases (47.9%) as the most useful. Regarding the disadvantages of SoMe, the respondents underlined the loss of personal contact (40.7%), the inability to get 'hands-on' training (38.7%), and the lack of control regarding quality of scientific evidence (37.1%). Social media is increasingly used for professional purposes for scientific updating, networking, and case-based learning. The results of this survey encourage scientific societies, journals, and authors to enhance the quality, reach and impact of scientific content provided through SoMe.


Asunto(s)
Medios de Comunicación Sociales , Adulto , Comunicación , Atención a la Salud , Femenino , Humanos , Masculino , Persona de Mediana Edad , Encuestas y Cuestionarios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA