Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 93(4): 574-582, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30311397

RESUMEN

BACKGROUND: There is a paucity of data on left main (LM) percutaneous coronary intervention (PCI) therapy with dedicated DES platforms. The LM-STENTYS is a multicenter registry aimed at evaluating clinical outcome after PCI of LM performed with a self-apposing Stentys DES implantation. METHODS: The registry consists of 175 consecutive patients treated with Stentys DES implanted to LM. The primary endpoint was the composite of major adverse cardiac and cerebral events (MACCE) defined as cardiac death, myocardial infarction (MI), target lesion revascularization (TLR), and stroke assessed after 1 year. The secondary endpoint was stent thrombosis (ST) at 1 year. RESULTS: The median age was 69 years (IQR, 62-78 years). Acute coronary syndrome (ACS) was the presenting diagnosis in 117 (66.9%) patients [74 (63.2%) unstable angina, 31 (26.5%) NSTEMI, 12 (10.3%) STEMI] and stable angina (SA) was present in 58 (33.1%) patients. The median SYNTAX score was 23.0 (IQR, 18.7-32.2) in the SA group and 25.0 (IQR, 20.0-30.7) in the ACS group. During 1-year follow-up in the SA group two (3.4%) MACCE occurred, both of them were cardiac deaths. In ACS patients there were 19 (16.2%) MACCE [9 (7.7%) cardiac deaths, 11 (9.4%) MIs, 11(9.4%) TLR, 1(0.9%) stroke]. Altogether, three (1.7%) cases of acute ST were noted, all of them in ACS subset. CONCLUSION: LM PCI using self-apposing Stentys DES showed favorable clinical outcomes at 1-year in patients with SA. Events of ST in the ACS group warrant further research.


Asunto(s)
Síndrome Coronario Agudo/terapia , Angina Estable/terapia , Angioplastia Coronaria con Balón/instrumentación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/mortalidad , Anciano , Angina Estable/diagnóstico por imagen , Angina Estable/mortalidad , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Recurrencia , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/mortalidad , Factores de Tiempo , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 91(1): 115-123, 2018 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-28843025

RESUMEN

BACKGROUND: Coronary artery disease (CAD) and degenerative aortic stenosis often coexist. However, the impact of CAD and its management on the prognosis after transcatheter aortic valve implantation (TAVI) remains uncertain. We sought to evaluate the impact of obstructive CAD, SYNTAX score (Ss), and percutaneous coronary intervention (PCI) prior to TAVI on short-term outcome. METHODS: Overall, 896 patients who underwent TAVI after heart team decision was included. Pre-procedural angiograms were analysed to calculate baseline Ss (bSs) and residual Ss (rSs). Baseline, procedural and follow-up data up to 30 days was acquired from the national POL-TAVI registry. RESULTS: Patients with obstructive CAD at baseline (n = 462, 52%) had higher mortality as compared with the remaining (8.7 vs. 5.1%, log-rank P = 0.039). Also, after correction for confounding factors obstructive CAD was identified as independent predictor of mortality (hazard ratio [HR] 1.74, 95% confidence intervals [CIs] 1.03-2.94, P = 0.037). In obstructive CAD, neither bSs (AUC 0.47, CI 0.38-0.56, P = 0.47) nor rSs (AUC 0.47, CI 0.30-0.64, P = 0.72 for those undergoing PCI and AUC 0.48, CI 0.37-0.59, P = 0.75 for the remaining) was predictive of mortality. When revascularization status was considered, patients with PCI prior to TAVI had similar outcome as those without obstructive CAD at baseline (7.7 vs. 5.1%, log-rank P = 0.23) with no negative impact on mortality (HR 1.13, CI 0.62-2.09, P = 0.69). CONCLUSIONS: In conclusion, obstructive CAD at baseline evaluation for TAVI has independent negative impact on short-term prognosis. However, neither baseline nor residual Ss values have prognostic ability in patients undergoing TAVI. Revascularization prior to TAVI seems to improve survival to levels comparable with patients without obstructive CAD at baseline.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Humanos , Masculino , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Polonia , Derivación y Consulta , Sistema de Registros , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 86(2): E49-57, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25599675

RESUMEN

AIMS: The effectiveness of revascularization of chronic total occlusion (CTO) remains intriguing. Thus, we sought to investigate whether a successful PCI for single CTO improves outcomes in a setting of stable angina and chronic occlusion of single coronary artery. METHODS AND RESULTS: Of 11 957 consecutive patients referred for nonurgent PCI between 2003 and 2010, 1110 displayed single CTO and were enrolled to the central CTO-registry database. The primary end-point included all-cause mortality, the secondary end-point a composite of safety outcome measure of all-cause death, nonfatal-MI, the need for urgent revascularization and stroke. The major adverse cardiovascular event (MACE) records were extracted from the national administrative database and all patients were linked to the long-term follow-up. Since the patient assignment was not random, we performed the propensity scoring to minimize selection bias; 734 patients (66%) had a successful PCI-CTO. Compared with successful procedures, unsuccessful procedures had similar rates of all-cause death both in crude (HR, 0.78; 95%CI, 0.49-1.25; P = 0.30) and adjusted analysis (HR, 0.80; 95%CI, 0.50-1.28; P = 0.34). A similar, significant reduction in overall MACE was noted with successful PCI-CTO compared with unsuccessful procedure in unadjusted (HR, 0.74; 95%CI, 0.56-0.96; P = 0.020) and adjusted calculation (HR, 0.73; 95%CI, 0.56-0.96; P = 0.019). Patients after successful PCI-CTO as compared with failed recanalization less frequently underwent surgical revascularization. The benefit was sustained at 3 years follow-up. CONCLUSIONS: Successful PCI for single CTO does not improve long-term survival, nonetheless, is associated with reduced overall MACE and the need for surgical revascularization.


Asunto(s)
Angina Estable/terapia , Oclusión Coronaria/terapia , Intervención Coronaria Percutánea , Anciano , Angina Estable/diagnóstico , Angina Estable/fisiopatología , Distribución de Chi-Cuadrado , Enfermedad Crónica , Oclusión Coronaria/diagnóstico , Oclusión Coronaria/mortalidad , Oclusión Coronaria/fisiopatología , Femenino , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Infarto del Miocardio/etiología , Oportunidad Relativa , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Puntaje de Propensión , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/etiología , Factores de Tiempo , Resultado del Tratamiento
6.
J Clin Med ; 12(16)2023 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-37629379

RESUMEN

In this article, we discuss the topic of chronic thromboembolic pulmonary disease (CTEPD) and the growing role of balloon pulmonary angioplasty (BPA) in its treatment. We present the pathophysiology of CTEPD which arises from an incomplete resolution of thrombi in the pulmonary arteries and leads to stenosis and occlusion of the vessels. The article focuses mainly on the chronic thromboembolic pulmonary hypertension (CTEPH) subpopulation for which prognosis is very poor when left untreated. We describe a multimodal approach to treating CTEPH, including pulmonary endarterectomy (PEA), BPA, and pharmacological therapies. Additionally, the benefits of pharmacological pre-treatment before BPA and the technical aspects of the procedure itself are outlined. It is emphasized that BPA does not replace PEA but serves as a complementary treatment option for eligible patients. We summarized efficacy and treatment goals including an improvement in functional and biochemical parameters before and after BPA. Patients who received pre-treatment with riociguat prior to BPA exhibited a notable reduction in the occurrence of less severe complications. However, elderly patients are still perceived as an especially vulnerable group. It is shown that the prognosis of patients undergoing BPA is similar to PEA in the first years after the procedure but the long-term prognosis of BPA still remains unclear. The 2022 ESC/ERS guidelines highlight the significant role of BPA in the multimodal treatment of CTEPH, emphasizing its effectiveness and recommending its consideration as a therapeutic option for patients with CTEPD, both with and without pulmonary hypertension. This review summarizes the available evidence for BPA, patient selection, procedural details, and prognosis and discusses the potential future role of BPA in the management of CTEPH.

7.
Kardiol Pol ; 81(11): 1103-1112, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37937354

RESUMEN

BACKGROUND: Impella is a percutaneous mechanical circulatory support device for treatment of cardiogenic shock (CS) and high-risk percutaneous coronary interventions (HR-PCIs). IMPELLA-PL is a national retrospective registry of Impella-treated CS and HR-PCI patients in 20 Polish interventional cardiological centers, conducted from January 2014 until December 2021. AIMS: We aimed to determine the efficacy and safety of Impella using real-world data from IMPELLA-PL and compare these with other registries. METHODS: IMPELLA-PL data were analyzed to determine primary endpoints: in-hospital mortality and rates of mortality and major adverse cardiovascular and cerebrovascular events (MACCE) at 12 months post-discharge. RESULTS: Of 308 patients, 18% had CS and 82% underwent HR-PCI. In-hospital mortality rates were 76.4% and 8.3% in the CS and HR-PCI groups, respectively. The 12-month mortality rates were 80.0% and 18.2%, and post-discharge MACCE rates were 9.1% and 22.5%, respectively. Any access site bleeding occurred in 30.9% of CS patients and 14.6% of HR-PCI patients, limb ischemia in 12.7% and 2.4%, and hemolysis in 10.9% and 1.6%, respectively. CONCLUSIONS: Impella is safe and effective during HR-PCIs, in accordance with previous registry analyses. The risk profile and mortality in CS patients were higher than in other registries, and the potential benefits of Impella in CS require investigation.


Asunto(s)
Corazón Auxiliar , Intervención Coronaria Percutánea , Humanos , Choque Cardiogénico/terapia , Polonia , Intervención Coronaria Percutánea/efectos adversos , Estudios Retrospectivos , Cuidados Posteriores , Alta del Paciente , Sistema de Registros , Resultado del Tratamiento
8.
Postepy Kardiol Interwencyjnej ; 18(1): 14-26, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35982740

RESUMEN

Introduction: Data regarding the duration of dual antiplatelet therapy (DAPT) in patients with drug-eluting stent restenosis (DES-ISR) treated with percutaneous coronary intervention (PCI) and drug-eluting balloons (DEB) or DES are not unambiguous. Aim: To evaluate the relationship between long-term outcomes and the length of DAPT in patients treated with PCI due to DES-ISR with DEB or DES. Material and methods: Overall, a total of 1,367 consecutive patients with DES-ISR, who underwent PCI with DEB or DES between 2008 and 2019 entered the study. The mean length of the follow-up was 1,298.7 ±794 days. We assessed study endpoints according to the duration of DAPT (≤ 3 vs. > 3 and ≤ 6 vs. > 6 months) before and after propensity score matching (PSM): stroke, target lesion revascularisation (TLR), target vessel revascularisation (TVR), myocardial infarction (MI), death and device oriented composite endpoints (DOCE). Kaplan-Meier estimates were created to differentiate long-term outcomes. Results: Pairwise contrast analysis considering type of PCI (DES vs. DEB) and duration of DAPT (≤ 6 vs. > 6 months) before PSM revealed superiority of DES + DAPT > 6 months vs. DEB + DAPT > 6 months for DOCE (p < 0.001), TVR (p = 0.02) and TLR (p = 0.01). Also, DES + DAPT ≤ 6 months was found to be superior compared to DEB + DAPT ≤ 6 months for DOCE (p < 0.001), TVR (p = 0.02) and TLR (p = 0.01). Kaplan-Meier estimate analysis confirmed that DAPT > 6 months is related to a higher stroke rate (p = 0.01) when compared to ≤ 6 months. Conclusions: Treatment with DAPT in patients with DES-ISR is related to better long-term outcomes in the case of PCI with DES than DEB. DAPT > 6 months is related to the greater rate of strokes, independently of the type of treatment (DES and DEB) than DAPT ≤ 6 months.

9.
Interv Cardiol ; 162021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33786063

RESUMEN

Cerebral embolic protection (CEP) devices aim to reduce the risk of periprocedural cerebrovascular events during transcatheter aortic valve implantation (TAVI). Here, the authors describe the first-in-human experience with the ProtEmbo Cerebral Protection System (Protembis), a next-generation CEP device, during TAVI. This case is part of a larger European trial evaluating the safety and performance of this device. After deployment of the ProtEmbo in the aortic arch, a first transcatheter heart valve was implanted. Despite postdilatation, moderate to severe aortic regurgitation persisted. The operating team decided to perform a valve-in-valve procedure using a second transcatheter heart valve. The ProtEmbo demonstrated good coverage of all three head vessels and no interaction with TAVI catheters in the aortic arch throughout the entire procedure. No adverse events were observed during hospitalisation or follow-up, and there was a significant reduction in aortic regurgitation at follow-up echocardiography. Despite a challenging overall procedure with presumably high embolic burden, diffusion-weighted MRI at follow-up showed a low number (n=3) and volume (156 mm3) of new hyperintense lesions. The first-in-human use of the ProtEmbo was safe and feasible, despite a challenging TAVI valve-in-valve procedure.

10.
Cardiol J ; 28(3): 384-390, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-30761515

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has become a standard therapeutic option for patients with severe aortic stenosis (AS) at high cardiac surgical risk. The aim of the NAUTILUS study was to investigate the safety and performance of the New Valve Technology (NVT) Allegra bioprosthesis in high-risk patients undergoing TAVI. METHODS: Twenty seven patients with severe, symptomatic AS at high surgical risk were prospectively enrolled, who underwent treatment using the novel self-expanding NVT Allegra bioprosthesis via transfemoral approach (TF-TAVI). The primary end-point was all-cause mortality at 30 days. RESULTS: Patients were elderly (83 years, range 75-89 years), and predominantly female (70.4%, n = 19). All patients were deemed to be at high surgical risk, with a mean logistic EuroSCORE of 12.4% (range, 2.8-31.8%). The bioprosthesis was successfully implanted in 96% of the cases (n = 25). The echocardiographic assessment confirmed good hemodynamic profile after implantation of the NVT Allegra bioprosthesis. Complications included cardiac tamponade (4%, n = 1) and the need for permanent pacemaker implantation (8%, n = 2). The analysis of procedural aspects showed a short learning effect related to the precise placement of the valve. A significant improvement in clinical symptoms were observed, and no patients died in-hospital or within 30 days of post-discharge observation. CONCLUSIONS: This prospective observation shows that the NVT Allegra bioprosthesis was associated with a satisfactory safety profile and a remarkable hemodynamic performance after implantation.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Cuidados Posteriores , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Alta del Paciente , Estudios Prospectivos , Diseño de Prótesis , Tecnología , Terfenadina/análogos & derivados , Resultado del Tratamiento
12.
Kardiol Pol ; 78(1): 45-50, 2020 01 24.
Artículo en Inglés | MEDLINE | ID: mdl-31719512

RESUMEN

BACKGROUND: Despite adequate heparinization, formation of fresh intracardiac thrombi during the MitraClip procedure was reported. AIMS: We aimed to evaluate the incidence and clinical consequences of intracardiac thrombus formation during the MitraClip device implantation. METHODS: Clinical data and transesophageal echocardiography findings obtained during MitraClip procedures in 100 consecutive patients (81 men; mean [SD] age, 67.8 [8.3] years) were reviewed. In all patients, a heparin bolus was given immediately after a successful transseptal puncture, and the activated clotting time above 250 seconds was maintained throughout the procedure. RESULTS: Thrombus formation was documented in 9 patients (9%). In 6 patients, thrombi formed on a transseptal needle/sheath (2 attached to the sheath in the right atrium and 4 on the sheath immediately after the puncture in the left atrium), and in 3 patients, on the MitraClip device in the left atrium (2 on a steerable guiding catheter and 1 on the clip delivery system). Overall, 6 thrombi (67%) formed prior to and 3 (33%) after heparin administration. All thrombi were transient and disappeared within minutes. No periprocedural ischemic stroke, transient ischemic attack, or other embolic complications were reported. Clinical characteristics were similar in patients with and without thrombi, except for lower left ventricular ejection fraction (LVEF; mean [SD], 23% [10%] and 30% [10%], respectively; P = 0.03). In-hospital death was reported in 6 patients: 2 with a visible thrombus and 4 without (P = 0.09). CONCLUSIONS: Transient thrombus formation is relatively common during the MitraClip procedure, especially in patients with low LVEF; however, acute clinical consequences are benign.


Asunto(s)
Trombosis , Función Ventricular Izquierda , Anciano , Ecocardiografía Transesofágica , Mortalidad Hospitalaria , Humanos , Incidencia , Masculino , Volumen Sistólico , Trombosis/epidemiología , Trombosis/etiología , Resultado del Tratamiento
13.
J Clin Med ; 9(4)2020 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-32331299

RESUMEN

Background: Evidence concerning the efficacy of the embolic protection devices (EPDs) in saphenous vein graft (SVG) percutaneous coronary intervention (PCI) is sparse. The study was designed to compare major cardiovascular events of all-comer population of SVG PCI with and without EPDs at one year of follow-up. Methods and results: A multi-center registry comparing PCI with and without EPDs in consecutive patients undergoing PCI of SVG. The group comprised 792 patients, among which 266 (33.6%) had myocardial infarction (MI). The primary composite endpoint was major adverse cardiac and cerebrovascular event (MACCE) defined as death, MI, target vessel revascularization (TVR), and stroke assessed at one year. After propensity score analysis, there were no differences in MACCE (21.9% vs. 23.9%; HR 0.91, 95% CI 0.57-1.45, p = 0.681, respectively) nor in secondary endpoints of death, MI, TVR, target lesion revascularization (TLR) and stroke at one year in EPDs PCI group vs. no-EPDs PCI group. Similarly, there were no differences between groups in the study endpoints at 30 days follow-up. Conclusions: There were no clinical benefit for routine use of EPDs during SVG PCI in short and long-term follow-up. Further studies are warranted to explore the effect of individual types of EPDs on clinical outcomes.

14.
Cardiol J ; 26(4): 310-321, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31257567

RESUMEN

BACKGROUND: A simplified formula to calculate the predicted fractional flow reserve (FFR) in sequen-tial coronary stenosis without balloon inflation is hereby proposed. METHODS: In patients with an indication for FFR and sequential coronary stenosis, FFR was recorded distally and between the lesions. The predicted FFR for each stenosis was calculated with a novel formu-la. While treating one of the lesions, wedge pressure was measured during balloon inflation to calculate Pijls' formula. FFR of the remaining lesion was finally recorded (measured FFR). RESULTS: Forty patients were enrolled in the study, 4 (10.0%) had a distal FFR > 0.80 and were excluded from the main analysis. In the remaining 36 patients, the novel formula and Pijls' formula showed virtually absolute agreement (ICCa 0.999, R2 = 0.997 for the proximal lesion, R2 = 0.999 for the distal lesion, kappa 1.000, Se 100%, Sp 100%). The agreement between predicted and measured FFR was good (ICCa 0.820; 0.640-0.909, R2 = 0.717, intercept = 0.05, slope = 0.92, kappa 0.748, Se 75%, Sp 96%). In 19 (47.5%) cases the use of the formula enabled the operator to freely decide which lesion should be treated first, an option not available if the percutaneous coronary intervention (PCI) were guided by the largest pressure drop across each lesion. CONCLUSIONS: The predicted FFR for each lesion in sequential coronary stenosis can be accurately calculated by a simplified formula circumventing the need for balloon inflation. This approach provides the operator upfront, with detailed information on physiology, thus having a potentially high impact on the corresponding PCI strategy.


Asunto(s)
Cateterismo Cardíaco , Enfermedad de la Arteria Coronaria/diagnóstico , Estenosis Coronaria/diagnóstico , Vasos Coronarios/fisiopatología , Reserva del Flujo Fraccional Miocárdico , Modelos Cardiovasculares , Anciano , Toma de Decisiones Clínicas , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea , Proyectos Piloto , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados
15.
Int J Cardiol ; 292: 56-61, 2019 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31003797

RESUMEN

BACKGROUND: Data regarding the efficacy of the percutaneous coronary intervention (PCI) with new-designed drug-eluting stent (new-DES) vs. bare metal stent (BMS) of saphenous vein grafts (SVG) stenosis is scarce. The primary objective was to compare one-year clinical outcomes of PCI in stenosis of SVG using new-DES vs. BMS in a real-world population. METHODS AND RESULTS: We carried out a multi-center registry comparing new-DES with BMS in all consecutive patients undergoing PCI of SVG. The primary composite endpoint was major adverse cardiac and cerebrovascular events (MACCE) at 1 year. This observation included 792 consecutive patients (mean age 69 ±â€¯8.9y), treated with either new-DES (n = 379, 47.9%) or BMS (n = 413, 52.1%). Among patients treated with new-DES compared with BMS, there was a lower risk of MACCE (21.4% vs. 28.3%, HR = 0.69, 95% CI 0.50-0.95, p = 0.025) as well as myocardial infarction (MI) (6.3% vs. 12.1%; HR 0.49, 95% CI 0.30-0.82, p = 0.005) at 1 year. After propensity score adjustment, the similar, significant reduction in MACCE and MI was observed in favor of new-DES (HR 0.66, 95% CI 0.46-0.96, p = 0.030; and HR 0.53, 95% CI 0.31-0.92, p = 0.020, respectively). CONCLUSION: In patients undergoing PCI of SVG, the use of new-DES is associated with a reduced 1-year rate of MACCE and MI compared to BMS.


Asunto(s)
Intervención Coronaria Percutánea/métodos , Vena Safena/trasplante , Stents , Anciano , Países Bálticos , Constricción Patológica , Stents Liberadores de Fármacos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Puntaje de Propensión , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
16.
Am Heart J ; 156(5): 964.e1-964.e5, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19061713

RESUMEN

BACKGROUND: The aim was to assess the influence of menstrual cycle on results of exercise echocardiography and electrocardiography. METHODS: Premenopausal women (n=28) with regular monthly menses, presented typical angina, positive electrocardiogram (ECG) exercise stress test, and normal coronary angiogram were recruited. Exercise supine bicycle echocardiography with simultaneous recording of 12-lead ECG was performed once a week for 4 consecutive weeks. Occurrence of angina, time to angina, time to significant ST deviation, and segmental myocardial contractility were analyzed. Blood samples were drawn to estimate follicle-stimulating hormone, luteinizing hormone, beta-estradiol, progesterone concentration and confirm the position in menstrual cycle. In correlation analysis, linear and logistic regression were used as appropriate. Qualitative variables were categorized into quartiles in logistic regression analysis. RESULTS: Exercise ST depression was more frequently observed in both luteal phases (early luteal 78%, late luteal 86%) compared to the late follicular phase (50%, P<.05). Time to ST depression was significantly longer in late follicular phase compared to other phases. The rate of segmental exercise left ventricular hypokinesis was low and not significantly related to menstrual cycle. Using linear regression, significant positive correlation was found between estradiol-progesterone ratio and time to ST depression. Using multiple logistic regression, we confirmed that progesterone level is independent factor influencing the presence of ST depression. CONCLUSION: In women with typical angina and normal coronary angiogram, the position in menstrual cycle influences the ST depression but not myocardial contractility during exercise echocardiography.


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Ecocardiografía de Estrés , Electrocardiografía , Prueba de Esfuerzo , Ciclo Menstrual/fisiología , Contracción Miocárdica , Premenopausia , Función Ventricular Izquierda , Adulto , Angina de Pecho/etiología , Dolor en el Pecho/etiología , Enfermedad de la Arteria Coronaria/complicaciones , Femenino , Humanos , Persona de Mediana Edad
17.
J Hypertens ; 25(8): 1650-4, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17620962

RESUMEN

OBJECTIVE: The sympathetic nervous system is a key modulator of prognosis and outcome in cardiac ischaemia and infarction. The effects of acute cardiac ischaemia on sympathetic neural traffic in humans are unknown. We tested the hypothesis that angioplasty, and associated transient myocardial ischaemia, elicits changes in neural circulatory control, including direct intraneural measures of sympathetic traffic. METHODS: We measured muscle sympathetic nerve activity (MSNA), blood pressure and heart rate in 12 patients (11 men, one woman) undergoing clinically indicated elective coronary angioplasty of the left anterior descending (n = 7) or circumflex (n = 5) coronary artery. Baseline data were obtained for 2 min before occlusion. Each balloon inflation was designed to last up to 120 s. RESULTS: Coronary occlusion had no significant effect on blood pressure or heart rate. In contrast, occlusion resulted in a significant increase in MSNA, in 10 of the 12 patients, and in all seven of those patients undergoing angioplasty of the left anterior descending artery. The group mean increase in MSNA during occlusion was 36 +/- 11% (P = 0.008 versus preocclusion). MSNA increased within 60 s of occlusion (129 +/- 12% of baseline; n = 12; P = 0.04), and increased further during the next 60 s to 141 +/- 12% of baseline levels (n = 10; P < 0.001). Increases in MSNA were similar in patients with and without significant chest pain (39 +/- 9% versus 34 +/- 13%, respectively; P = 0.84). CONCLUSION: Acute coronary occlusion during angioplasty increases central sympathetic outflow, but there is no systematic change in heart rate. The increase in sympathetic nerve traffic cannot be explained by blood pressure changes or occlusion-related chest pain.


Asunto(s)
Angioplastia de Balón , Enfermedad Coronaria/fisiopatología , Sistema Nervioso Simpático/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad
19.
Cardiol J ; 24(4): 426-435, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28653314

RESUMEN

Fractional flow reserve (FFR) is an evidence-based diagnostic tool of physiological significance of coronary artery stenosis in patients with stable coronary artery disease (CAD). Due to microvascular dysfunction in acute coronary syndrome (ACS), information obtained from FFR assessment could be less reliable and, thus, its clinical role remains controversial. Indeed, results of currently published studies are essentially discrepant. Only a few randomized clinical trials have been performed showing the efficacy of FFR-guided percutaneous coronary intervention in ACS. Consequently, its role in acute scenarios remains substantially understudied. Herein, is presented the current state of knowledge re-garding FFR use in ACS setting. (Cardiol J 2017; 24, 4: 426-435).


Asunto(s)
Síndrome Coronario Agudo/diagnóstico , Cateterismo Cardíaco , Vasos Coronarios/fisiopatología , Reserva del Flujo Fraccional Miocárdico , Síndrome Coronario Agudo/fisiopatología , Síndrome Coronario Agudo/terapia , Humanos , Hiperemia/fisiopatología , Microcirculación , Valor Predictivo de las Pruebas , Pronóstico , Vasodilatadores/administración & dosificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA